{
    "DeviceClass": "79f0c163-0c13-4662-9dea-09235fef90cb", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "HPE IB NDR/EN 400Gb 1p QSFP112 Adptr", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "28_49_1014-MCX715105AS-WEAT_Ax.pldm.signed", 
                        "InstallDurationSec": 900, 
                        "Order": 1, 
                        "PLDMImage": true, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": true, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "a6b1a447-382a-5a4f-15b3-102115b30237", 
                "Version": "28.49.1014"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "Firmware - Network"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter : HPE part number S5R60A"
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Networking"
                    }
                ]
            }, 
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "9603379", 
                "DateModified": "2026-06-25T07:47:20", 
                "FileList": [
                    "28_49_1014-MCX715105AS-WEAT_Ax.pldm.signed", 
                    "28_49_1014-MCX715105AS-WEAT_Ax.pldm.xml", 
                    "payload.json"
                ], 
                "MD5Sum": "e2ca685b3f98be9adabf37fcd1013c52", 
                "Name": "28_49_1014-MCX715105AS-WEAT_Ax.pldm.fwpkg", 
                "Release": "2026-06-25T07:45:14", 
                "Revision": "", 
                "SHA1Sum": "b42d2071ba70c458ddcd0fec0b48f3fab9a5823b", 
                "SHA256Sum": "db2b33631bd7c2739138203176821101f46c379c876957a3d60941c6677e4c5b", 
                "Size": "9.16MB", 
                "TargetGUIDs": [
                    "a6b1a447-382a-5a4f-15b3-102115b30237"
                ], 
                "TypeOfChange": "1", 
                "Version": "28.49.1014"
            }
        ], 
        "Id": {
            "Product": "163971813d65441fb10908957d409424", 
            "Version": "f3db15fbb83a4424a932e99bc97f79c0"
        }, 
        "Installation": {
            "Command": "", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "no"
            }, 
            "PerDeviceInstallTimeSeconds": 900, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "yes", 
            "RebootRequirement": "Required"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"margin-left:40px\">\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter : HPE part number S5R60A"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "32000"
            }, 
            "SupportedDevices": [
                {
                    "Dev": "1021", 
                    "SubDev": "0237", 
                    "SubVen": "15B3", 
                    "TargetGUID": "a6b1a447-382a-5a4f-15b3-102115b30237", 
                    "Type": "pci", 
                    "Ven": "15B3"
                }
            ], 
            "SupportedOperatingSystems": [
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 9 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "15", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 15", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "1", 
                    "Name": "VMware ESXi 9.1", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "16", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 16", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 10", 
                    "Platform": "Red_Hat_Enterprise_Linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minimumbuild": "25399", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2025", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "25398", 
                    "Minimumbuild": "20317", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2022", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 9.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 8.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2026-07-12T09:47:03", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p><strong>New features and changes included in version 28.49.1014:</strong></p>\n\n<ul>\n\t<li>Added support for Congestion-Control histogram collection in the PCC/ZTR-RTT algorithm. After enabling this capability, customers can read RATE and RTT histogram counters for PCC-managed flows.</li>\n\t<li>Added a new parameter to the ZTR_RTTCC algorithm to define the probe-packet timeout threshold.</li>\n\t<li>Added support for a new packet reformat type for PSP transport packets. This reformat removes the PSP trailer and the UDP + PSP transport headers, and updates the IP Protocol field based on the PSP next_header value.</li>\n</ul>\n", 
                        "Fixes": "<p><strong>The following issues have been fixed in version 28.49.1014:</strong></p>\n\n<ul>\n\t<li>NSM Get-Port-Network-Addresses returned an invalid format on B200/B300 HMC. It now follows the documented non-compact format.</li>\n\t<li>An issue that could prevent the adapter&rsquo;s PCIe link from re-establishing after the host resumed from a deep power-down state. This fix improves the reliability of suspend/resume cycles.</li>\n\t<li>A DEAD IRISC assert that could occur during TLV NV_DATA flash access by suspending the watchdog while waiting for flash IPC (until timeout), preventing the assert on TLV access.</li>\n\t<li>An issue where repeatedly writing NVCONFIG TLVs could cause excessive NV_DATA partition swaps during garbage collection. This rapid cycling could accelerate flash wear (end-of-life at 100,000 erases) and potentially render the device inoperable. Firmware now avoids unnecessary physical writes by returning OK when the requested configuration already exists in flash, and increases the maximum supported NV_DATA partition swaps from 100,000 to 200,000.</li>\n\t<li>ICM_RES_HW_DMFS_ENCAP_H_FW was allocated per GVMI, preventing some RTTs from using it.</li>\n\t<li>vDPA doorbell resources were not released, which could cause failures when running other functionality after a vDPA FLR. Doorbell resources are now properly unlocked.</li>\n\t<li>RDMA traffic could stall in large-scale deployments for certain source IP and UDP source-port combinations when DOCA PCC was active and no congestion-control algorithm was configured in algorithm slot 0.</li>\n\t<li>The live migration target did not receive a port state change event on the resume VHCA command. The target now generates this event so software that depends on port state is notified of any changes.</li>\n\t<li>A precopy image was processed during the stop-copy phase, causing prolonged downtime due to a software limitation. The handling was slow because the handler performed a linear search for data; this was improved by replacing it with a faster search approach enabled via compile-time preprocessing.</li>\n\t<li>QPs established before loading DOCA PCC could exhibit inconsistent algorithm-selected behavior between ports in LAG mode after DOCA PCC is loaded.</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "28.49.1014"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p><strong>New features and changes included in version 28.48.1000:</strong></p>\n\n<ul>\n\t<li>Improved the ADP-RETX algorithm to avoid re-arming without performing a retransmission.</li>\n\t<li>The DOCA PCC NP application now enables the NIC to insert the RTT response transmit timestamp in hardware, reducing software-induced jitter and improving the accuracy and consistency of RTT measurements.</li>\n\t<li>The system-wide limit for DPA processes has been reduced to 30. This total includes both user processes across all GVMIs and internal ProgCC processes. The max_dpa_processes value reported to the user is calculated as: max_dpa_processes=30&minus;number_of_progcc_processes</li>\n\t<li>Added &nbsp;MAD (Management Datagram) access to the new &nbsp;Adaptive Retransmission Histogram &nbsp;registers. Users can configure the &nbsp;histogram &nbsp;by issuing &nbsp;VSP MAD GET/SET operations to ADP_RETX_HISTOGRAM_CONFIG (0xC01D), and retrieve histogram data via VSP MAD GET to ADP_RETX_HISTOGRAM_READ (0xC01E) (using the required VSP MAD header values and TLV format). This enables configuring and collecting adaptive retransmission timeout statistics through the MAD interface.</li>\n\t<li>Host rate limiting has been extended to support bandwidth values above 255 Gbps. To remove the previous cap, a new max_bw_value_msb field was added to est_global, providing additional MSB bits to represent higher bandwidth values. With this enhancement, firmware and host tooling can correctly configure and report rate limits beyond 255 Gbps on high-speed links.</li>\n\t<li>PLDM now supports the PDR Repository Change event type, enabling notification to the BMC when PDRs change. With this flow, the BMC can detect cable insertion/removal events.</li>\n\t<li>Added support for running save and load operations in parallel, enabling multiple contexts (e.g., multiple VFs) to be checkpointed and restored concurrently instead of serially. This reduces overall migration time and improves scalability in environments that need to migrate or recover many VFs at once.</li>\n\t<li>Extended packet modify-header operations to support set and copy actions on the NVGRE VSID (Virtual Subnet Identifier) . A new field, TUNNEL_HDR_DW_2 (0x84), enables dynamic VSID modification, adding header rewrite support for NVGRE tunnel traffic in addition to existing filtering capabilities.</li>\n\t<li>Added a new output field, migration_state, to QUERY_VHCA_MIGRATION_STATE. Software uses this field to make live-migration flow decisions, specifically to signal when it is not a good time to transition into the stop-copy stage.</li>\n\t<li>To align with updated Microsoft UEFI Secure Boot requirements and the upcoming end-of-life of the 2011 Certificate Authority (CA), a transition to the 2023 CA has been done.&nbsp;To ensure successful loading of the Expansion ROM (ExpROM) during the UEFI Secure Boot process, system BIOS and operating system trust stores must be updated to include the 2023 CA.<br />\n\t<strong>Note:</strong>&nbsp;When performing a firmware update of ConnectX and BlueField devices the new certificate is required for Secure Boot. To continue supporting Secure Boot, systems must be updated to recognize the &quot;Microsoft Option ROM UEFI CA 2023&quot;.</li>\n</ul>\n", 
                        "Fixes": "<p><strong>The following issues have been fixed in version 28.48.1000:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>An interoperability issue where, when ConnectX-7 communicates with ConnectX-8 using the probe-based algorithm, bandwidth could become extremely low due to probe packets being dropped.</li>\n\t<li>The DPA kernel used unsafe ICM access during process creation/modification, which would cause the DPA kernel to hang during FLR.</li>\n\t<li>User Debugger &ldquo;query caps&rdquo; returned only the number of capabilities, not the capability bitmap.</li>\n\t<li>Race condition in standby/boot power sequencing. In certain timing windows, port power-down would be delayed such that the power-up flow detected the port still transitioning to power-down, causing the sequence to fail and leaving the port stuck in a powered-down state.</li>\n\t<li>mlxlink reported 0 values for SNR (media and host) due to incorrect local port mapping in firmware and an incorrect page number used by MFT.</li>\n\t<li>Due to an SMBus release race condition, the I2C bus would become stuck.</li>\n\t<li>Fuse values were not aligned with the updated values burned across different ConnectX-7 setups.</li>\n\t<li>Issue in the steering definers used for LAG with IPv6 traffic.</li>\n\t<li>A spurious CNP was sent in response to an out-of-sequence packet.</li>\n\t<li>The root complex sent MCTP-over-PCI messages before a BDF was assigned, causing responses to be sent with BDF 0. The fix ensures that MCTP messages routed by ID are ignored until a valid BDF is assigned.</li>\n\t<li>The steering tables were not updated after enabling partial Spectrum-X capabilities (BTH.AR) via LLPD.</li>\n\t<li>When decapsulation on a packet occurred, the FCS indication was not calculated correctly.</li>\n\t<li>In IB system, RTT_response_sl feature did not work with Sniffer tools (e.g., Wireshark/Tcpdump/).<br />\n\t&nbsp;</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "28.48.1000"
            }
        ], 
        "SWKeys": [
            {
                "Name": "Mellanox_NIC_PLDM_WEAT-MCX715105AS_VPI", 
                "SWKeyExpectedPath": "firmware:nic"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U70", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U70)"
            }, 
            {
                "Family": "U72", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U72)"
            }, 
            {
                "Family": "A59", 
                "Model": "HPE ProLiant Compute XD685"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "Firmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}