    "DeviceClass": "aa148d2e-6e09-453e-bc6f-63baa5f5ccc4", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "System BIOS - U70", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "U70_1.30_03_21_2025.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": true, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000277", 
                "Version": "v1.30 (03/21/2025)"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "BIOS - System ROM"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "67121179", 
                "DateModified": "2025-03-21T07:25:18", 
                "FileList": [
                    "U70_1.30_03_21_2025.signed.flash"
                ], 
                "MD5Sum": "963395952bdb4d5581b69774fe02d748", 
                "Name": "U70_1.30_03_21_2025.fwpkg", 
                "Release": "2025-03-21T07:21:57", 
                "Revision": "", 
                "SHA1Sum": "de52281eb57ea09a8ec27b8b0d930f1d677be61e", 
                "SHA256Sum": "e50c396b7c0454ccfc177188c9200063d6f45a2b271b8e5b70e1561e0ef604cb", 
                "Size": "64.01MB", 
                "TargetGUIDs": [
                    "00000000-0000-0000-0000-000000000277"
                ], 
                "TypeOfChange": "1", 
                "Version": "1.30_03-21-2025"
            }
        ], 
        "Id": {
            "Product": "f2a63f15af75433da30e835b983f61c7", 
            "Version": "54984c05610340b8bc5080d8c8aa002a"
        }, 
        "Installation": {
            "Command": "cpqsetup.exe", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "yes"
            }, 
            "PerDeviceInstallTimeSeconds": 300, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "yes", 
            "RebootRequirement": "Required"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO6_IP_Address&gt; -u &lt;iLO6_username&gt; -p &lt;iLO6_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "ROM Flash Firmware Package - System ROM for HPE ProLiant Compute DL380a Gen12 (U70)"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "11000"
            }, 
            "SupportedDevices": [], 
            "SupportedOperatingSystems": [
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "7", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 7.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 8.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2025-04-21T07:21:46", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "Resolved various issues to improve system stability and performance.", 
                        "Fixes": "Resolved various issues to improve system stability and performance.", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.30_03-21-2025"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>Implemented VMD structure boot string to include more information for each VMD devices. </p><p>Enhanced Chinese translation support for some options. e.g. \"core\", \"enabled\", \"disabled\", \"locked\", etc.</p><p>Grayed out RBSU \"pcie data link feature\" option in \"System Configuration > BIOS/Platform Configuration (RBSU) > PCIe Device Configuration > Advanced PCIe Configuration\".</p><p>Added support for 2-DIMM and 4-DIMM population.</p><p>Added RBSU \"HardwarePM Interrupt\" option in \"System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options > Advanced Power Options\".</p><p>Added the \"Smooth Cooling\" selection to the Thermal Configuration option in the RBSU\\Advanced Options\\Fan and Thermal Options.  This selection modifies the fan speed response to improve acoustics by reducing the rate of fan speed changes. This can improve acoustics for workloads which significantly vary CPU utilization. Note that this option can result in a small reduction in performance due to the short durations of CPU thermal throttling and some operating systems, such as Linux, may log CPU thermal throttling events. These events do not indicate an issue with the system and can be ignored.</p>", 
                        "Fixes": "<p><strong>Important Notes:</strong></p>This version of the system rom contains updates aligned with Intel SRF-SP PLR1.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p>\n<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system would use UUID for IPV6 DHCP when DUID-LLT is selected.</p><p>Addressed an issue where the system might have uncorrectable memory errors with Samsung 32Gb 3DS 256GB RDIMM.</p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p>Addressed an issue where the system RBSU did not list MCTP knob in \"System Configuration > BIOS/Platform Configuration (RBSU) > PCIe Device Configuration > Advanced PCIe Configuration > PCIe MCTP Options\"</p><p>Addressed an issue where the system would list additional network ports in RBSU network page, e.g. \"System Configuration > BIOS/Platform Configuration (RBSU)->Network Options->Network Boot Options->PCIe Slot Network Boot\".</p><p>Addressed an issue where the system might not report fatal severity status when having EINJ fatal errors.</p><p>Addressed an issue where the system might bring up a warning message (\"ERST: [Firmware Warn]: too many record IDs!\") in the Linux environment during boot up.</p><p>Addressed an issue where the system might failed to start QAT.service in the Linux environment when Sub-NUMA clustering enabled.</p><p>Addressed an issue where the system cooling might not be adjusted to maximum when applied \"Maximum Cooling\" in RBSU.</p><p>Addressed an issue where the system might not log processors crash error when having UPI error.</p><p>Addressed an issue where the system might failed to update NVMe drive firmware.</p><p>Addressed an issue where the system might get USB termination test failed result when performing WS2022 CERT. </p><p>Addressed an issue where the system Package C6 value might be incorrect in the IDLE C State.</p><p>Addressed an issue where the system OCP slot strings in redfish resources might not align with RBSU menu.</p><p>Addressed an issue where the system might failed when performing FWTS in the Linux environment.</p><p>Addressed an issue where the SR-IOV options cannot be disabled in RBSU menu.</p><p>Addressed an issue where the system might hang in early POST when setting processor RAPL wattage value greater than Max wattage.</p><p>Addressed an issue where the system NVMe drives firmware information may display incorrectly in RBSU firmware update page.</p><p>Addressed an issue where the system unsupported Intel speed select technology performance profile might be listed in RBSU menu.</p><p>Addressed an issue where the system boot order in iLO web is not matched with Boot Order Control in RBSU menu.</p><p><strong>Known Issues:</strong></p>None", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.20_01-17-2025"
            }
        ], 
        "SWKeys": [
            {
                "Name": "U70", 
                "SWKeyExpectedPath": "firmware:system"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U70", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U70)"
            }, 
            {
                "Family": "U70", 
                "Model": "HPE ProLiant Compute DL380a Gen12"
            }, 
            {
                "Family": "FTP", 
                "Model": "FTP-Only System"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "Firmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}