{
    "DeviceClass": "79f0c163-0c13-4662-9dea-09235fef90cb", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "HPE_MR932i-p_Gen12", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "HPE_MR932i-p_8.16.2.0-01003-00002_A.HPb", 
                        "InstallDurationSec": 360, 
                        "Order": 1, 
                        "PLDMImage": true, 
                        "ResetRequired": false, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": true, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "a6b1a447-382a-5a4f-1000-00b315900453", 
                "Version": "8.16.2.0-01003"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "Firmware - Storage Controller"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "Universal Firmware PLDM file for the HPE MR932i-p Controller"
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Storage"
                    }
                ]
            }, 
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "6153086", 
                "DateModified": "2026-05-14T02:26:20", 
                "FileList": [
                    "HPE_MR932i-p_8.16.2.0-01003-00002_A.HPb", 
                    "HPE_MR932i-p_8.16.2.0-01003-00002_A.xml", 
                    "payload.json"
                ], 
                "MD5Sum": "c7d63f16949fe8f311d6f74261296f3b", 
                "Name": "HPE_MR932i-p_8.16.2.0-01003-00002_A.fwpkg", 
                "Release": "2026-05-14T02:22:27", 
                "Revision": "", 
                "SHA1Sum": "3bc8babcc386a014856da8f25b2ff81459ed6987", 
                "SHA256Sum": "9f2d85dcf9caa87091cfaa6e81922a67719d46d9a221acf7af6bd15f18747e61", 
                "Size": "5.87MB", 
                "TargetGUIDs": [
                    "a6b1a447-382a-5a4f-1000-00b315900453"
                ], 
                "TypeOfChange": "1", 
                "Version": "8.16.2.0-01003-00002"
            }
        ], 
        "Id": {
            "Product": "4dace5a803344041ad392f9b2b571002", 
            "Version": "edd637a94ee34f199ab1adc3e4c0494c"
        }, 
        "Installation": {
            "Command": "", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "no"
            }, 
            "PerDeviceInstallTimeSeconds": 360, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is not required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "no", 
            "RebootRequirement": "No"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n\n<p>Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "Firmware Package - HPE MR932i-p Controller"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "8000"
            }, 
            "SupportedDevices": [
                {
                    "Dev": "00B3", 
                    "SubDev": "0453", 
                    "SubVen": "1590", 
                    "TargetGUID": "a6b1a447-382a-5a4f-1000-00b315900453", 
                    "Type": "pci", 
                    "Ven": "1000"
                }
            ], 
            "SupportedOperatingSystems": [
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "15", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 15", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "25398", 
                    "Minimumbuild": "20317", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2022", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 9 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minimumbuild": "25399", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2025", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 9.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 10", 
                    "Platform": "Red_Hat_Enterprise_Linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "16", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 16", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2026-06-14T02:00:23", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "", 
                        "Fixes": "<p>TBD</p>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "8.16.2.0-01003-00002"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<ul>\n\t<li>DMTF PLDM Redfish Device Enablement enhancements\n\t<ul>\n\t\t<li>Redfish Volume Transformation Support\n\t\t<ul>\n\t\t\t<li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li>\n\t\t\t<li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li>\n\t\t\t<li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li>\n\t\t\t<li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Redfish Metrics GET Support\n\t\t<ul>\n\t\t\t<li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, UncorrectableParityErrorCount, StateChangeCount</li>\n\t\t\t<li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li>\n\t\t\t<li>DriveMetrics: BadBlockCount, ReadIOKiBytes, WriteIOKiBytes, PowerOnHours, NVMeSMART (MVMeSMART attributes are supported for NVMe drive only)</li>\n\t\t\t<li>EnvironmentMetrics for Drive Resource: TemperatureCelsius.Reading</li>\n\t\t\t<li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li>\n\t\t\t<li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Add support for UBM11 backplane</li>\n\t<li>Refine the message on HII prereview configuration for the foreign import</li>\n\t<li>Standardize PSoC printing versioning info as 2 digit major/2 digit minor for Hardware and Firmware</li>\n</ul>\n", 
                        "Fixes": "<ul>\n\t<li>Fix a00157381en_us Advisory: HPE MR932i-p Storage Controller - Incorrect Controller Port Number To Box Number Mapping in iLO GUI</li>\n\t<li>Fix a00157199en_us Advisory: HPE MR932i-p Storage Controller - The &quot;StorageDevice.1.2.BatteryOK&quot; Event Is Not Consistently Generated When the Energy Pack Is Reconnected to an HPE MR932i-p Storage Controller</li>\n\t<li>Fix a00157775en_us Advisory: HPE MR932i-p Storage Controller - Cache-Offload Event Is Not Reported in the Integrated Management Log (IML) Via Redfish</li>\n\t<li>Fix an issue that backplane firmware update fails if more than 16 slots are connected to the MR932i-p controller.</li>\n\t<li>Fix an issue that Redfish POST ResetToDefaults.PreserveVolumes operation fails with Unsupported Operation.</li>\n\t<li>Fix an issue that &quot;Controller status changes to failed&quot; event is generated when doing firmware update. Please note the event may still happen when downgrading firmware to 8.15.1.0-01003-00001 since the fix is not available in the old version</li>\n\t<li>Fix an issue that DriveOffline and DriveOfflineCleared events are logged when auto rebuild start on the re-inserted drive</li>\n\t<li>Fix an issue that Energy Pack temperature sensor thresholds are reported incorrectly</li>\n\t<li>Fix an issue that SCSI Device ModeSense failures with format corruption warnings on ESXI9.0 OS after boot</li>\n\t<li>Fix an issue that firmware may not identify the drive properly to puncture when more than one rebuild/copyback tasks running.</li>\n\t<li>Fix a rare issue that controller is stuck at DDR SPD i2c read during reboot test</li>\n\t<li>Fix a rare issue that controller may hang in cache offload module after factory repurpose command issued followed by a power cycle</li>\n\t<li>Fix an issue that arbitrary firmware image size value used in platform measurement when reading data</li>\n\t<li>Fix a rare issue that drives might be marked as failed with phy toggling after creating volume.</li>\n\t<li>Fix a rare issue that Energy Pack communication fail does not reflect, and causes cache offload failed</li>\n\t<li>Fix a rare issue that firmware hang caused by the NAND flash hardware entering a bad state after a program failure while doing factory repurpose</li>\n\t<li>Fix an issue that changing LKM to EKM encryption mode using Redfish fails</li>\n\t<li>Fix an issue that controller status shows &quot;Need Attention&quot; in RBSU menu when drives are connected to controller</li>\n\t<li>Fix an issue that auto assignment is not applied on the auto-configured JBOD in a fresh boot.</li>\n\t<li>Remove &ldquo;Encrypted@Redfish.AllowableValues&quot; to match Boolean type behavior</li>\n\t<li>Fix an issue that controller firmware fault might be observed when partial-capacity volumes are assigned to different physical functions and moved to Offline.</li>\n\t<li>Fix a rare case that controller may fault when the foreign drive&#39;s primary DDF record is invalid</li>\n\t<li>Fix a potential controller fault triggered by frequent drive medium errors during Online Capacity Expansion</li>\n\t<li>Fix a rare issue that particular NVMe drive model state changes to Unusable with drive hotplug</li>\n\t<li>Fix a rare issue that SED may fail to reprovision if the drive is removed during import and controller reset</li>\n\t<li>Fix a potential controller fault triggered by IO counter mismatches during overlapping FLR (Function Level Reset) and task management operations</li>\n\t<li>Fix a rare issue that firmware fault may occur if a drive takes too long (over 70s) to fix errors, especially during task management</li>\n\t<li>Fix a potential issue that alternative boot chain recovery fails to trigger if secure boot authentication has failed</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "8.16.1.0-01003-00004"
            }
        ], 
        "SWKeys": [
            {
                "Name": "04531590", 
                "SWKeyExpectedPath": "firmware"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U68", 
                "Model": "HPE Alletra Storage Server 4210"
            }, 
            {
                "Family": "U72", 
                "Model": "HPE ProLiant Compute DL580 Gen12"
            }, 
            {
                "Family": "I46", 
                "Model": "HPE Synergy 480 Gen12 Compute Module"
            }, 
            {
                "Family": "A55", 
                "Model": "HPE ProLiant DL365 Gen11 Server"
            }, 
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL320 Gen12 Server"
            }, 
            {
                "Family": "A55", 
                "Model": "HPE ProLiant DL385 Gen11 Server"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute ML350 Gen12"
            }, 
            {
                "Family": "U72", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U72)"
            }, 
            {
                "Family": "", 
                "Model": "HPE ProLiant DL380m Gen12"
            }, 
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL340 Gen12 Server"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute DL360 Gen12"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute DL380 Gen12"
            }, 
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL325 Gen12 Server"
            }, 
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL345 Gen12 Server"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "Firmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}