{"Manifests":[{"AffectedList":[],"AuthenticationDetails":{},"AuthenticationMethod":"","BundleISOLocation":"","BundleId":"2026.07.00.00","CompLocation":"","ComponentDownloadServer":"","DefaultComponentDownloadServer":"","DeniedList":[],"Manifest":[{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-i40e-kmp-default-2.28.16_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"e527ee35330c66107c60b48e55d25737dc66d7ec","SHA256Sum":"08e07d8053bf69184a6647f28f10110c5090bd2d1ce6788771e05bbae56d4abe","SHA512Sum":"86aab32c8de7ef735eb149f43b59dff3b722d6c70a6a5a460f9d3424778ef900f328ef5b23da945a8cf069544f8849efaf3d74fc1067b723ebe9ad523e23e263"}],"ComponentSizeInKB":437,"CompsigList":["hp-i40e-kmp-default-2.28.16_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"Name":"hp-i40e-kmp-default-2.28.16_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"e527ee35330c66107c60b48e55d25737dc66d7ec","SHA256Sum":"08e07d8053bf69184a6647f28f10110c5090bd2d1ce6788771e05bbae56d4abe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.28.16-1"},{"Checksum":[{"Filename":"hp-i40e-kmp-default-2.28.16_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"8d1fbf226856e931a140fc9a6b727074f9a051f9","SHA256Sum":"8130906b37083ad44413579cc1dfc6ec41f30889c6d23ef518b78866fb787e32","SHA512Sum":"5349bdd321bb5901b1d3edc9d6783839edb6c91b31d8b9ba11be21ed7d5130a9b84f279c27f415680f46d50050bd349789f05a4f0dd7187b9c75a5ee0f8a5a59"}],"ComponentSizeInKB":436,"CompsigList":["hp-i40e-kmp-default-2.28.16_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"Name":"hp-i40e-kmp-default-2.28.16_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"8d1fbf226856e931a140fc9a6b727074f9a051f9","SHA256Sum":"8130906b37083ad44413579cc1dfc6ec41f30889c6d23ef518b78866fb787e32","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.28.16-1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"Name":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f10636eb13a740379af4fbca0d","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"237.1.148000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"bcm237.1.148000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"237.1.148000"}]},"Files":[{"Checksum":[{"Filename":"bcm237.1.148000.Optimized.fwpkg","SHA1Sum":"a18a2cfd56462b65690691abe394b08503d7695a","SHA256Sum":"ef9f7abd4690fbebbce1763cd3dd07f84d769fcfd49851b6b3c4ddc993fc52d7","SHA512Sum":"57751d74d7ada13a677924c31e3faa4d9465c1bba56a267c51881e667d3e342f2378d2e31de954a076380d2a9e96db7b80a07242fd138c238cc88183e1d19db1"}],"ComponentSizeInKB":8398,"CompsigList":[],"FileList":["bcm237.1.148000.Optimized.HPb","bcm237.1.148000.Optimized.xml","payload.json"],"Name":"bcm237.1.148000.Optimized.fwpkg","SHA1Sum":"a18a2cfd56462b65690691abe394b08503d7695a","SHA256Sum":"ef9f7abd4690fbebbce1763cd3dd07f84d769fcfd49851b6b3c4ddc993fc52d7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"TypeOfChange":"1","Version":"237.1.148000"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107000","Name":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"NIC_NXE_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8b143626256048aab85c4d60e6","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U40","U39","U64"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","SHA1Sum":"57ae2f4e61510c35a5bc5449cd3e6d6145ddaf21","SHA256Sum":"4fcce98b217a4fe670dace26c0a10e111d9d617ff802995cb54bd1a529075ec8","SHA512Sum":"a85f41712c23b0be003aa2a892330f3da0932075bd1c9023beb60c4aa64277cbbf83a11674d35c9be855aab5f75709a5659e553547c421bdd6356d1db4152c8c"}],"ComponentSizeInKB":5009,"CompsigList":["firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/CP068859.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068859.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068859.scexe"],"Name":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","SHA1Sum":"57ae2f4e61510c35a5bc5449cd3e6d6145ddaf21","SHA256Sum":"4fcce98b217a4fe670dace26c0a10e111d9d617ff802995cb54bd1a529075ec8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d6229f8dc1e47bdbf9d5dbc3f","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"cp072110.exe","SHA1Sum":"a11fb67c888b081bcc7dbb9e3ed0a7c5b9dffaf9","SHA256Sum":"69f72a0a9ad8eefb74d4a2f21b149806e284db9e0b2ad41d36d577474b189967","SHA512Sum":"d8d4a6605828c4c2ad6106748cece5df6117478843fc4c60310f8b0597ed34c32c4ebc6ddd67655c87a517a0ca3f04d932aab4ea9540a446a4a8c2af16a74076"}],"ComponentSizeInKB":3774,"CompsigList":["cp072110.compsig"],"FileList":["QLAFWUpdate.exe","adapters.properties","bk020502.bin","cp072110.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021114.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"Name":"cp072110.exe","SHA1Sum":"a11fb67c888b081bcc7dbb9e3ed0a7c5b9dffaf9","SHA256Sum":"69f72a0a9ad8eefb74d4a2f21b149806e284db9e0b2ad41d36d577474b189967","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2022 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":250,"RebootRequired":"yes","SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7a716a33c1994ec0bf295c6268","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069696.exe","SHA1Sum":"094a78dd7721ba6aa3a4f78dea138aaddb07a73d","SHA256Sum":"734da7bf563045929b968b4bd2e5feff0d03f704fa1edc1c10bea898f32b54c2","SHA512Sum":"208ed479c5b47f1b08ab93d246091ec820c9b8fc38dd6f1c3de2869f3be11c2506bc65c7924f4f5db4b0909b175cc553c712a98815ec185c1614c8e24a186ec8"}],"ComponentSizeInKB":610,"CompsigList":["cp069696.compsig"],"FileList":["cp069696.xml","cpqsetup.exe","installer.dll","pnp/","pnp/NULL_HECI.cat","pnp/NULL_HECISystem.inf","pnp/RocketLake.cat","pnp/RocketLakeSystem.inf","pnp/TigerLakePCH-H.cat","pnp/TigerLakePCH-HSystem.inf"],"Name":"cp069696.exe","SHA1Sum":"094a78dd7721ba6aa3a4f78dea138aaddb07a73d","SHA256Sum":"734da7bf563045929b968b4bd2e5feff0d03f704fa1edc1c10bea898f32b54c2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19886.8592"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eb805e4703474f4d9f67ea754a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399","10.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","U60","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072213.exe","SHA1Sum":"40704ec9ccfdd8d1918ab7430ed7e2a5149b1ba2","SHA256Sum":"7fe414ab4d068d4cd033e9ce2d884d882357a416f79fca28824ca870d52fea0b","SHA512Sum":"81c6a1153d0f8851d05e79a9efe364f49cd57d992365641e0d9a4687ff2b30fef50c2ec47346ead9e1c1fdc5bcb163a7524a88de034a955c158ac5d95374c4f1"}],"ComponentSizeInKB":609,"CompsigList":["cp072213.compsig"],"FileList":["cp072213.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"Name":"cp072213.exe","SHA1Sum":"40704ec9ccfdd8d1918ab7430ed7e2a5149b1ba2","SHA256Sum":"7fe414ab4d068d4cd033e9ce2d884d882357a416f79fca28824ca870d52fea0b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"6.4.8.206"}],"InstallationDependency":{},"Name":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42d69affd54d4260ba08659b76","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A40","A43","A41","A46","A47","A42","A43","A43","A42","A48"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM9A3_GPM9A3SAHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3438-304b584c5846","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","SHA1Sum":"2c23039e2f867225671fab0fcc1b9a982089fae1","SHA256Sum":"34e915bce71521266b3218cf37d2e1c1c0356161eaf17d09daa806633be4da48","SHA512Sum":"0258b498eb36187a81244b63daeb9e4d1517671799ad2a1abbdf11e34d1e449de38e5fa83af80924da72dccd7e99e7ea9884bfe942085bb22d799a37ad744171"}],"ComponentSizeInKB":3091,"CompsigList":[],"FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK4.HPb","Samsung_PM9A3_GPM9A3SAHPK4.xml"],"Name":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","SHA1Sum":"2c23039e2f867225671fab0fcc1b9a982089fae1","SHA256Sum":"34e915bce71521266b3218cf37d2e1c1c0356161eaf17d09daa806633be4da48","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b584c5846"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000480KXLXF","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KXLXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f8a034bd867140ceab209744ed","SupportedDevices":["562340a5-3052-3030-3438-304b584c5846"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068891.exe","SHA1Sum":"fff93966dfa7fe378f149ea21fe35aafde45b606","SHA256Sum":"9aebde01016044a753e0a101a45365c4dbc57749e0d65a775ddff1de763d9b30","SHA512Sum":"10bcaf85b731d9623a1c30b3776680018b280682ac4efb5217f8280d75932ca6acde7cbcefed20fd3b359faba2d9e924e68ccf4ea8ac156448768a1ac8db4b53"}],"ComponentSizeInKB":53682,"CompsigList":["cp068891_part1.compsig","cp068891_part2.compsig"],"FileList":["cp068891.xml","cpqsetup.exe","cp_data.xml","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"Name":"cp068891.exe","SHA1Sum":"fff93966dfa7fe378f149ea21fe35aafde45b606","SHA256Sum":"9aebde01016044a753e0a101a45365c4dbc57749e0d65a775ddff1de763d9b30","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"TypeOfChange":"1","Version":"8.16.13.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"lsa.exe","SWKeyExpectedPath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_da9ea0f674284c5bb3e75189ab","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"DL20ML30Gen10SPS_05.01.05.103.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"DL20ML30Gen10SPS_05.01.05.103.fwpkg","SHA1Sum":"ec35db27fe71bae2c0a45332c8063f5f228bae85","SHA256Sum":"aac1c46ae909251f6ad8448b13a229fad61baa94deaff6ad075f577bf258f829","SHA512Sum":"f6e90da9dd178a329b3ac86784b1f5d900934f689df32625d225ccb845d03177fe9349267096cdda1c9c8c4ecd136bb14d8c9e4bb4bbf1f11ac84be6f29aafaa"}],"ComponentSizeInKB":1959,"CompsigList":[],"FileList":["DL20ML30Gen10SPS_05.01.05.103.signed.bin","DL20ML30Gen10SPS_05.01.05.103.xml","payload.json"],"Name":"DL20ML30Gen10SPS_05.01.05.103.fwpkg","SHA1Sum":"ec35db27fe71bae2c0a45332c8063f5f228bae85","SHA256Sum":"aac1c46ae909251f6ad8448b13a229fad61baa94deaff6ad075f577bf258f829","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e553de6b27bd43e982e1d4c580","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U43","U44"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072125.exe","SHA1Sum":"eb4a6dc85cd145a837f97d23ce7d070bd942715b","SHA256Sum":"421acde3f433fb673d9d2dc2a5343ef0035783dd76f9baf876d60e8859c0bc00","SHA512Sum":"d86f8118cbf42d5d6345e3ac85add8502a279007176fda6125408e4459c16f2900da25da907e4267603c5e887122f0f1b96db7678fa64d1f92a6e40337a9aa0f"}],"ComponentSizeInKB":3304,"CompsigList":["cp072125.compsig"],"FileList":["cp072125.xml","cpqsetup.exe","M52002TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072125.exe","SHA1Sum":"eb4a6dc85cd145a837f97d23ce7d070bd942715b","SHA256Sum":"421acde3f433fb673d9d2dc2a5343ef0035783dd76f9baf876d60e8859c0bc00","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0ea92126033f4244a2f4aa640b","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"CP070837.zip","SHA1Sum":"24b45e9f8c2de8d1509bddd1b01931e613f4c4cc","SHA256Sum":"9b33e83409cdf472ca25bc1d91fd48c47a3876166468294b43a30a3c45b2969a","SHA512Sum":"3047e0ecdf8f6401590fe8dc14960f56f215a36c45c94a437ac374cfb5acb5d0e59deb0c415832839768d2d93675b6ca95745be9fb1de4445d08117358946cae"}],"ComponentSizeInKB":18140,"CompsigList":["CP070837.compsig"],"FileList":["/CP070837_BUILD_3.data","/CP070837.vmexe64","/CP070837.vmfile","/CP070837_VMw.zip","/CP070837.xml","/payload.json","/CP070837_VMw.zip/index.xml","/CP070837_VMw.zip/vendor-index.xml","/CP070837_VMw.zip/metadata.zip","/CP070837_VMw.zip/vib20/CP070837/HPE_bootbank_CP070837_4ICRHPK3.3-8.0.0.20613240.vib","/CP070837_VMw.zip/metadata.zip/vendor-index.xml","/CP070837_VMw.zip/metadata.zip/vmware.xml","/CP070837_VMw.zip/metadata.zip/vibs/CP070837-4626515825514893688.xml","/CP070837_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070837_4ICRHPK3.3-8.0.0.20613240.xml"],"Name":"CP070837.zip","SHA1Sum":"24b45e9f8c2de8d1509bddd1b01931e613f4c4cc","SHA256Sum":"9b33e83409cdf472ca25bc1d91fd48c47a3876166468294b43a30a3c45b2969a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3","VibList":[{"Name":"CP070837","Version":"4ICRHPK3.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_96311744a0b246349db25dab30","SupportedDevices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.fwpkg","SHA1Sum":"1c8fc46d9362c4006516cb20ffee972052e50fbd","SHA256Sum":"3d2ef2b0962bdb360c4bd2a96d3c9acef1c6466e9bc163f7d350b4e3549d111d","SHA512Sum":"1b8e73f67071bbb9f9b9217a062347d565ef4f0fb00c1e75724e6d709802adf3088d84688730c9a10cf78ecbbba384278cc42e37a10907badcd5a7689b244357"}],"ComponentSizeInKB":5216,"CompsigList":[],"FileList":["16_35_8008-MCX512F-ACH_Ax_Bx.pldm.signed","16_35_8008-MCX512F-ACH_Ax_Bx.pldm.xml","payload.json"],"Name":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.fwpkg","SHA1Sum":"1c8fc46d9362c4006516cb20ffee972052e50fbd","SHA256Sum":"3d2ef2b0962bdb360c4bd2a96d3c9acef1c6466e9bc163f7d350b4e3549d111d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30116"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX512F-ACHT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0691dac6f40a41d9b4ebca041a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U47","A46","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U30","U32","U60","U54","U54"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"tg3-kmp-default-3.139y_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","SHA1Sum":"cc5e06961b8aacc7b8573e2a732825a637374e09","SHA256Sum":"4d417d6811d910d4baa68e3fdfe062d1fa50a16147f8a82d0247585602e1780e","SHA512Sum":"7bc92ec838e9ad6d4f53d70de9727577cb195cf0a1b3e8384537570d3495304c94a2720918cdb079e882504f41e4291f998f33eb9715744bd8874a403629f2ae"}],"ComponentSizeInKB":123,"CompsigList":["tg3-kmp-default-3.139y_k6.4.0_150600.21-2.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.139y_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","SHA1Sum":"cc5e06961b8aacc7b8573e2a732825a637374e09","SHA256Sum":"4d417d6811d910d4baa68e3fdfe062d1fa50a16147f8a82d0247585602e1780e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139y-2"},{"Checksum":[{"Filename":"tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","SHA1Sum":"df8679e5a8b56ddfc49015dd4203c9a13448a2ad","SHA256Sum":"b18d8a5c25e87649e885e1a76ae7385cf3a9b004bb6dd7b936d9785ff7639eb0","SHA512Sum":"6c8644a53ff69028665df5fef2a33ebbdae4cc2aa27dc91a7266fccc29d25e5f36bce06637e4a5e5c635a42992e463dcbd9a6afc900d6f763ebb036190ae8e86"}],"ComponentSizeInKB":125,"CompsigList":["tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","SHA1Sum":"df8679e5a8b56ddfc49015dd4203c9a13448a2ad","SHA256Sum":"b18d8a5c25e87649e885e1a76ae7385cf3a9b004bb6dd7b936d9785ff7639eb0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139y-2"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_beff1447c68947528d417b5f65","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U47","U40","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U72","U70","U68","A66","A66","03030202","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071582.exe","SHA1Sum":"85e214195843046490dd2f7dccea5a1a5cb987a9","SHA256Sum":"a95aa78c296b0037053f70a0647b8470b86e2257a033c39f8c47fa3dc18645a1","SHA512Sum":"07da38cb213a7aa30de9f4a75e817c9fe599c74321e1f4f1000c47b44411e77d725ab9736766d97c1dce3072723cf239c52200fd6f591f9718ab19ea826e3e0d"}],"ComponentSizeInKB":33435,"CompsigList":["cp071582_part1.compsig","cp071582_part2.compsig"],"FileList":["A47_4.04_04_02_2026.signed.flash","cp071582.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071582.exe","SHA1Sum":"85e214195843046490dd2f7dccea5a1a5cb987a9","SHA256Sum":"a95aa78c296b0037053f70a0647b8470b86e2257a033c39f8c47fa3dc18645a1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d413d2a7d664cd08900d49001","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U64_2.64_04_01_2026.fwpkg","SHA1Sum":"1d4e62346b1b581f25d16493b3c645cfb841235e","SHA256Sum":"87e7a1114b800a4a053c5d8bffb0abf4ad4b8462706dd3c2ed0e286c57db7ce1","SHA512Sum":"982d40ecb3e6286fbb8447fda6810c7a9040f729a83c73d5d684b9308078eb1d5cd25917a3a05bf82e6d38c8a1c1c018aa5d12ac968ac5d51ea86488f720b7b9"}],"ComponentSizeInKB":16419,"CompsigList":[],"FileList":["payload.json","U64_2.64_04_01_2026.signed.flash","U64_2.64_04_01_2026.xml"],"Name":"U64_2.64_04_01_2026.fwpkg","SHA1Sum":"1d4e62346b1b581f25d16493b3c645cfb841235e","SHA256Sum":"87e7a1114b800a4a053c5d8bffb0abf4ad4b8462706dd3c2ed0e286c57db7ce1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ce43f934bbb48139a005469e4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072381.zip","SHA1Sum":"e4d6869a59dfa2714e1fd6bcfa9e8a3042efbb33","SHA256Sum":"7df51076a33bac3533cedbbe045df9d873dc2d85047bac50d12dedb139c3148f","SHA512Sum":"7c512b0fd86bf0d3c784ba74440a88f9260fcedd683b7a3545cb10dae4331dbedd61b6ac745880fceb3a50a72b8b4951529fea6a51c9854400e543461349b0cc"}],"ComponentSizeInKB":16290,"CompsigList":["CP072381.compsig"],"FileList":["/CP072381.xml","/CP072381_VMw.zip","/payload.json","/CP072381.vmexe64","/CP072381.vmfile","/CP072381_VMw.zip/index.xml","/CP072381_VMw.zip/vendor-index.xml","/CP072381_VMw.zip/metadata.zip","/CP072381_VMw.zip/vib20/CP072381/HPE_bootbank_CP072381_1.0.2-1OEM.900.0.24755229.vib","/CP072381_VMw.zip/metadata.zip/vendor-index.xml","/CP072381_VMw.zip/metadata.zip/vmware.xml","/CP072381_VMw.zip/metadata.zip/vibs/CP072381-7047738796017372873.xml","/CP072381_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072381_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072381.zip","SHA1Sum":"e4d6869a59dfa2714e1fd6bcfa9e8a3042efbb33","SHA256Sum":"7df51076a33bac3533cedbbe045df9d873dc2d85047bac50d12dedb139c3148f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072381","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_768259f2d4064386950b73a309","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","SHA1Sum":"df129b058635f8a851fa802deda698e30d2705e0","SHA256Sum":"ea1001cc06988b542ee1892e0e53c8c93aa0cbe2de3ec0cf74a757f5adf33581","SHA512Sum":"a214cefdcfa383e1463c7fa660d8ec83a60a54c77258ed62ef6aad809f2c531ae2558d191682fb8624f96c5ab5f7e5ca56a85563d4ae710a60227aa5f6bff2ec"}],"ComponentSizeInKB":5747,"CompsigList":["firmware-hdd-42aff4675b-HPD5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/CP068923.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068923.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068923.scexe"],"Name":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","SHA1Sum":"df129b058635f8a851fa802deda698e30d2705e0","SHA256Sum":"ea1001cc06988b542ee1892e0e53c8c93aa0cbe2de3ec0cf74a757f5adf33581","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1acfb6855d7e460f8e0c563239","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3531-3330-305058444256","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"a85e6a8d2bc9643ee7effbae5676e36a29391947","SHA256Sum":"9336c451573a77ece275fccdc388944e4515e15ac7686f9c0a7bc596d7f5a453","SHA512Sum":"921e58d41356a223c86c65eda3ae0ecd55296435c2478a795a37a810deb70b18a3a97497ac6dd52a2563c4d487f694eafd8601fbeee742d33ae17b71e0b3b497"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.signed","20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"a85e6a8d2bc9643ee7effbae5676e36a29391947","SHA256Sum":"9336c451573a77ece275fccdc388944e4515e15ac7686f9c0a7bc596d7f5a453","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec3d440efe554dd3a41ae6e2f4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U62","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4706"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"cp072409.exe","SHA1Sum":"17b616100bf4b4f247e704d4ded3b55d8057fb57","SHA256Sum":"8258d8a1cd833a1d02e547e53f25a5f241297115377fdfed36f9aa93ecde5767","SHA512Sum":"588f12d519cfdb131dea20cc2a54a5d938c8d79c60eda1e31b78068158b96fc1a19fc420c93a94066fb22f7077918e66cb00760b0ae9fcbbb38c216331df585e"}],"ComponentSizeInKB":26997,"CompsigList":["cp072409.compsig"],"FileList":["cp072409.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072409.exe","SHA1Sum":"17b616100bf4b4f247e704d4ded3b55d8057fb57","SHA256Sum":"8258d8a1cd833a1d02e547e53f25a5f241297115377fdfed36f9aa93ecde5767","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.0.18"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_52e36eafdb29438aae24ab5ed2","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A47","A48","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U37","A42","U56","U27","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"CP070857.zip","SHA1Sum":"ffedf089cff457188cfa3c2c4d9915a2ca24f689","SHA256Sum":"86ff9e92a615888d8a1ef4f5569c43ac0d8b4f2400a14c1cb32049456b71dee1","SHA512Sum":"d6661caa9556520d098466a904c4ee0b243fb4229d2bef53740544f4b6a70b45eccdbd6347ed73bce54af111a98aad52db35dd2d89f6f7ed4b8e843ef66d8ab9"}],"ComponentSizeInKB":17171,"CompsigList":["CP070857.compsig"],"FileList":["/CP070857_BUILD_5.data","/CP070857.vmexe","/CP070857.vmexe64","/CP070857.vmfile","/CP070857_VMw.zip","/CP070857.xml","/payload.json","/CP070857_VMw.zip/index.xml","/CP070857_VMw.zip/vendor-index.xml","/CP070857_VMw.zip/metadata.zip","/CP070857_VMw.zip/vib20/CP070857/HPE_bootbank_CP070857_1.27.5-8.0.0.20613240.vib","/CP070857_VMw.zip/metadata.zip/vendor-index.xml","/CP070857_VMw.zip/metadata.zip/vmware.xml","/CP070857_VMw.zip/metadata.zip/vibs/CP070857--3744643468949072851.xml","/CP070857_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070857_1.27.5-8.0.0.20613240.xml"],"Name":"CP070857.zip","SHA1Sum":"ffedf089cff457188cfa3c2c4d9915a2ca24f689","SHA256Sum":"86ff9e92a615888d8a1ef4f5569c43ac0d8b4f2400a14c1cb32049456b71dee1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27","VibList":[{"Name":"CP070857","Version":"1.27.5-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":240,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec76c6ce1cac4a33ab5731ba66","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","8.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","SHA1Sum":"17858aa2a8590fdb2faab13c5c487c65ba32cd83","SHA256Sum":"c1c1d7c0069241cdbc33ce9c8057fb30775d2539a718443aa87b960e994cc00a","SHA512Sum":"bf0d7dd6f56f8153ae5125145a3cc39a3d4d58a1cf724ab85cc3628db746f1636bf3683c6c399c66673ad877be69003b08f694ed230ce24ca71dec816e2997d5"}],"ComponentSizeInKB":5878,"CompsigList":["firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/CP068804.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068804.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068804.scexe"],"Name":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","SHA1Sum":"17858aa2a8590fdb2faab13c5c487c65ba32cd83","SHA256Sum":"c1c1d7c0069241cdbc33ce9c8057fb30775d2539a718443aa87b960e994cc00a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f8863e8510334a8fb6bd7e4316","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072374.exe","SHA1Sum":"fa7dc1d79096055dd638abdb2db92b338ac5d773","SHA256Sum":"f0e0a1eac865538c5c47955210165396326538b3d1830f8bc93e774040e6b5ed","SHA512Sum":"e6f3e8fbaa4fd76d3f8fb55c9ccffb46601a82e27087c69b692e940bd01aa3870fcfcd678ddb8e25696e804782ea76ef2822cf3a6c2f95f26c00d29958b54cd5"}],"ComponentSizeInKB":27681,"CompsigList":["cp072374.compsig"],"FileList":["cp072374.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072374.exe","SHA1Sum":"fa7dc1d79096055dd638abdb2db92b338ac5d773","SHA256Sum":"f0e0a1eac865538c5c47955210165396326538b3d1830f8bc93e774040e6b5ed","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.0.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8792fb7da0f44d89a52050c82c","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.deb","SHA1Sum":"4ac856d35a43d3dcc4370ffb222b231a46e82444","SHA256Sum":"908372dac49325de0533112949507c0d17fb60466f2bd5c29c63fb50f7fdd8e0","SHA512Sum":"f7afd5ae13c76b80185ebed1fdf87ae3755613d394fc5428d54a4424aa8a23a18fb5e65e60074b1525eb0c18ca26218746743520da160c74a83784105cd2be48"}],"ComponentSizeInKB":4004,"CompsigList":["firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/CP071775.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/TATCATSATAG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071775.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071775.scexe"],"Name":"firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.deb","SHA1Sum":"4ac856d35a43d3dcc4370ffb222b231a46e82444","SHA256Sum":"908372dac49325de0533112949507c0d17fb60466f2bd5c29c63fb50f7fdd8e0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_93013fee33d943c18951b5045b","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-035a863453_0HPK5-2.1_amd64.deb","SHA1Sum":"e2f60cbc70f4711ae0da4651d599cfb9c151b6e7","SHA256Sum":"38804b9b07d4e3637e4c2888903fa5e3e2ad1adb58f2d34ad92e8730600a6d38","SHA512Sum":"06ede65219c4a4680c7e4022ccc36b72f8d9c6087326086dd52440aef3f5e0a08f061e9c8f1493e7fc2d791f6498f48ddd1e48eb269a2612f6ea564db3a3e1f0"}],"ComponentSizeInKB":3597,"CompsigList":["firmware-hdd-035a863453_0HPK5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/CP071753.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071753.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071753.scexe"],"Name":"firmware-hdd-035a863453_0HPK5-2.1_amd64.deb","SHA1Sum":"e2f60cbc70f4711ae0da4651d599cfb9c151b6e7","SHA256Sum":"38804b9b07d4e3637e4c2888903fa5e3e2ad1adb58f2d34ad92e8730600a6d38","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_137dd96e196d4c1aaf24f632ab","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"26_49_1014-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.49.1014"}]},"Files":[{"Checksum":[{"Filename":"26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"e1cf4e07146af9a4a49b08ad018b411b14e587b7","SHA256Sum":"89f8ece84fdabd5f60085dc317816189aeab3e6b43baa8433ee3aeeb39159fa4","SHA512Sum":"4b82e6c4165f11379c2c2a58d6eb08c3b1c94538c1a99a7667054a98646ae45013f58bea4de748563f3367978ed447cc8d33243dafefa9e746eff70b642f566d"}],"ComponentSizeInKB":7171,"CompsigList":[],"FileList":["26_49_1014-MCX631102AS-ADA_Ax.pldm.signed","26_49_1014-MCX631102AS-ADA_Ax.pldm.xml","payload.json"],"Name":"26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"e1cf4e07146af9a4a49b08ad018b411b14e587b7","SHA256Sum":"89f8ece84fdabd5f60085dc317816189aeab3e6b43baa8433ee3aeeb39159fa4","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"TypeOfChange":"1","Version":"26.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631102AS-ADAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_057f5ac9bad54ea28ca65adba1","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U63","U65","U65","U68","U68","U68","A59","A66","A66","U72","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071514.exe","SHA1Sum":"ca8e7b7534f6f845fbc21815f8bed6a68b0d5385","SHA256Sum":"72a0557963c09f47ec692ed53c75fa67e0c2b5fd337585a3b437e849cd736305","SHA512Sum":"53a217893cc48a9d8d552b05a6cb7d37b8bbd651983fb3c4c308381cc610ed72b7e2d0dc4bd4d34446c9e32029f8b0d7a6fb828b110eb272e71315e97045612c"}],"ComponentSizeInKB":33443,"CompsigList":["cp071514_part1.compsig","cp071514_part2.compsig"],"FileList":["A43_4.04_04_02_2026.signed.flash","cp071514.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071514.exe","SHA1Sum":"ca8e7b7534f6f845fbc21815f8bed6a68b0d5385","SHA256Sum":"72a0557963c09f47ec692ed53c75fa67e0c2b5fd337585a3b437e849cd736305","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_177c1fd153c546f19de544df3b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068638.exe","SHA1Sum":"b131f072e1418aecdca2ade8cfe75d27a422ce74","SHA256Sum":"863210e5ac6f4761322dce27b70e425e4a7ad009cf478737edf21f2c6348b71b","SHA512Sum":"89f77a5638da0cffa4af5ddb5a54af61874c3a7dfb8a0a20f60c2ab9ec383c334e49ed5025d87263b14198b1acca7a56e7ae31b2ef4eb27d2fd278ca4c320e56"}],"ComponentSizeInKB":3363,"CompsigList":["cp068638.compsig"],"FileList":["cp068638.xml","cpqsetup.exe","GPM1645ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068638.exe","SHA1Sum":"b131f072e1418aecdca2ade8cfe75d27a422ce74","SHA256Sum":"863210e5ac6f4761322dce27b70e425e4a7ad009cf478737edf21f2c6348b71b","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b0168ec5461d4a2c884ee180be","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U30_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u30-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"c489a68aa84b0a1f6141fcbaf51d9e337a965091","SHA256Sum":"d6a314975e1c31407f68ff5934195a03dd06ebab6a33725224269e47d67d6bf1","SHA512Sum":"7104d73a253bd2ff8239b0ac3027be8fe4e44d234b0a666faee45175334e46a3ca9c434ec5996719ce182a6d536dd3e860b045b3d79de083057cfb203db86fa8"}],"ComponentSizeInKB":11685,"CompsigList":["firmware-system-u30-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/CP071355.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/U30_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071355.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071355.scexe"],"Name":"firmware-system-u30-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"c489a68aa84b0a1f6141fcbaf51d9e337a965091","SHA256Sum":"d6a314975e1c31407f68ff5934195a03dd06ebab6a33725224269e47d67d6bf1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3da1161cfe745cba555b83b4b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"cp069607.exe","SHA1Sum":"f37922cfcb32c0ab27f57886127205222c0118b9","SHA256Sum":"eff91846781264d2ec7fddd521ac097395e732e87ae7113e1d5315febbb1c1b7","SHA512Sum":"3c706aa8b6ef48090abf1e9f175bd140b417ab502d1f9efb6e45493bbfa7eef99f021d8d6e232127d00862fd00ce940d4a5613809e9e8df4904692c536eb1601"}],"ComponentSizeInKB":667,"CompsigList":["cp069607.compsig"],"FileList":["cp069607.xml","cpqsetup.exe","LICENSE.txt","payload.json","PICGen10_v1.1.4_hdr.signed.hex","SecureFlash64.dll"],"Name":"cp069607.exe","SHA1Sum":"f37922cfcb32c0ab27f57886127205222c0118b9","SHA256Sum":"eff91846781264d2ec7fddd521ac097395e732e87ae7113e1d5315febbb1c1b7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7bdaa82f3b0243c79e8496b113","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["A43","A42","A43","A42","A43","A42","A41","A40","U34","U34","U46","U30","U46","U32","U31","U60","U43","U32","U41","U33","U61","U44","U50","U39","U50","U39","U56"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hponcfg-6.1.0-0.x86_64.rpm","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","SHA512Sum":"16d4f74e61ba339db4494dfaf2047f503572ffcb718405204a869228b65dab706f4fdecf414e1390dd49b00098441c34d91232f306200ca4a2a70c07571e003a"}],"ComponentSizeInKB":62,"CompsigList":["hponcfg-6.1.0-0.x86_64.compsig"],"FileList":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"Name":"hponcfg-6.1.0-0.x86_64.rpm","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"TypeOfChange":"0","Version":"6.1.0.0"}],"InstallationDependency":{},"Name":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hponcfg","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6abdf231475c435c92bb558b96","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I38","I32","A26","I41","I36","I31","I30","U34","U17","P79","U34","P85","P77","P89","A42","A40","A28","U46","U30","P89","P70","P73","A42","U46","U32","P89","P71","P73","A43","A43","A43","A41","P80","J05","U31","U20","U31","U20","J03","U36","P86","U15","U15","U43","U22","U41","P92","P72","J02","P78","J04","P95","U33","P99","U44","U23","O42","J10","P88","P74","P75","P75","P75","P75","P83","U51","U18","U18","U18","A47","A48","U40","U21","U50","U39","U47","U45","U25","U24","U24","U13","U37","U13","A46","U47","P94","A48","U38","U14","U38","U14","U48","J06","U26","I36","I31","A45","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U47","U47","Carbondale14","Carbondale14","Carbondale14","U50","U19","U46","I40","I43","I39","I40","I45","I44","I42","I37","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U64","U58","R11","U65","U65","U65","H11","U69","A58","R13","U69","U70","U66","A59","HPE ProLiant ML150 Gen10 Server","O43","U38","U38","U38","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_MR416i-p_Gen10P_52.36.3-6584_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.36.3-6584"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR416i-p_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"99d7148ba12b3aab874337591cbc413d35c561e8","SHA256Sum":"e4d0de7380bed017650492917228c918c56f8c3bb7806d566ab7a973f7064635","SHA512Sum":"9073e6af6f1b5a21ddf22d0c2bc20e00509b617dcbcdc37392bbeb8818db578b12ec906de47005ca48483d9971e6a1550bc87b994831f95c7c7fe35fd4ab902e"}],"ComponentSizeInKB":7341,"CompsigList":[],"FileList":["HPE_MR416i-p_Gen10P_52.36.3-6584_A.HPb","HPE_MR416i-p_Gen10P_52.36.3-6584_A.xml","payload.json"],"Name":"HPE_MR416i-p_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"99d7148ba12b3aab874337591cbc413d35c561e8","SHA256Sum":"e4d0de7380bed017650492917228c918c56f8c3bb7806d566ab7a973f7064635","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.36.3-6584"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_73d08a678c8e452bbf8f9e5f9f","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U33_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071382.exe","SHA1Sum":"c1e1248d6d047ffa154121d72f2d3ea2a5bd8444","SHA256Sum":"523dc3c9d560805439dad36ac7ef055e8b745fc0dc1fa6eddf68f1c80d1da798","SHA512Sum":"3fa0be9dfb93e6d125be1da26028ff4491c5652b789238cc1daf1804abd06862d76e91d0a5514a1de8d364c09b3b96c588cbe623ae96dd01c574f665e7637c93"}],"ComponentSizeInKB":11285,"CompsigList":["cp071382.compsig"],"FileList":["cp071382.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_3.66_04_01_2026.signed.flash"],"Name":"cp071382.exe","SHA1Sum":"c1e1248d6d047ffa154121d72f2d3ea2a5bd8444","SHA256Sum":"523dc3c9d560805439dad36ac7ef055e8b745fc0dc1fa6eddf68f1c80d1da798","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c6336467ac4a43438eb194338b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8a0371a425_0HPDC-2.1_amd64.deb","SHA1Sum":"06a5325f50491fa51b3a58c10b60c3ab78b4f3ed","SHA256Sum":"6062ebb198c31d868b5a8f66cfbc9d8a7b3669c3d57cb91836bf7db3c204b94c","SHA512Sum":"375d445e6cd6e95198950abbb45c7ba6adac4d010864fe91975b060225bb7872183d946fede8d8b57b96ebd406821d81b83a34fd73ed091c9f3d41986efcf081"}],"ComponentSizeInKB":4359,"CompsigList":["firmware-hdd-8a0371a425_0HPDC-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/CP071792.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/TAMG08scHPDC.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071792.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071792.scexe"],"Name":"firmware-hdd-8a0371a425_0HPDC-2.1_amd64.deb","SHA1Sum":"06a5325f50491fa51b3a58c10b60c3ab78b4f3ed","SHA256Sum":"6062ebb198c31d868b5a8f66cfbc9d8a7b3669c3d57cb91836bf7db3c204b94c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2af1f4d7bca945e2b8044c7a3e","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"CP072107.zip","SHA1Sum":"bca2e34f0617b02a0003221c55699ead44cdacae","SHA256Sum":"597eeb634d6111715fb7efe206a268095e55c29247fe8db34c0828b5aaeefaf8","SHA512Sum":"f8ca2088862163510ac3124cc17a72575dc1bb1f77525614efd7a753471a8935227dfcd4e3adfdd405d2729ba46288e597d9b618f4ee30cbb2be8b255ec50328"}],"ComponentSizeInKB":7764,"CompsigList":["CP072107.compsig"],"FileList":["/CP072107_BUILD_1.data","/CP072107.vmexe","/CP072107.vmexe64","/CP072107.vmfile","/CP072107_VMw.zip","/CP072107.xml","/payload.json","/CP072107_VMw.zip/index.xml","/CP072107_VMw.zip/vendor-index.xml","/CP072107_VMw.zip/metadata.zip","/CP072107_VMw.zip/vib20/CP072107/HPE_bootbank_CP072107_2026.06.02.1-8.0.0.20613240.vib","/CP072107_VMw.zip/metadata.zip/vendor-index.xml","/CP072107_VMw.zip/metadata.zip/vmware.xml","/CP072107_VMw.zip/metadata.zip/vibs/CP072107-4808322845179425364.xml","/CP072107_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072107_2026.06.02.1-8.0.0.20613240.xml"],"Name":"CP072107.zip","SHA1Sum":"bca2e34f0617b02a0003221c55699ead44cdacae","SHA256Sum":"597eeb634d6111715fb7efe206a268095e55c29247fe8db34c0828b5aaeefaf8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02","VibList":[{"Name":"CP072107","Version":"2026.06.02.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c98712c88e44f4eb25afe0940","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.rpm","SHA1Sum":"43bfd10066e2d0c4abc3e47acfd854d2438a72f4","SHA256Sum":"4f4001783373cca16d13f202b1e8bc268b176eabbaec985f9d04269783ef3c6c","SHA512Sum":"db75e1b9becee6c9882f19d5eff25081069244b50d21aa294f5084df7570838de164dd7988581718ce4a86c77fec855226fb8d23976c73cb915a207d7245da3c"}],"ComponentSizeInKB":5436,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.rpm","SHA1Sum":"43bfd10066e2d0c4abc3e47acfd854d2438a72f4","SHA256Sum":"4f4001783373cca16d13f202b1e8bc268b176eabbaec985f9d04269783ef3c6c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Update 1 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_44e21d14ab074e93920087a448","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072193.exe","SHA1Sum":"fbfe310ba4ad4732dfe3c438a5fc66cd3cee7912","SHA256Sum":"6dfaaa60c89d3b9b3f38dc608335a3bb6cdcc12bfcbfb936f44c21c7deba51a1","SHA512Sum":"a2f02172489a879d2855cfc06c0f83315c732847c22e2c827b502ebb0d2c78f80417c91e9a65ce20d0dc52a6a39423a834a70daf1bec4b6835995ddb576d086c"}],"ComponentSizeInKB":2434,"CompsigList":["cp072193.compsig"],"FileList":["cp072193.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072193.exe","SHA1Sum":"fbfe310ba4ad4732dfe3c438a5fc66cd3cee7912","SHA256Sum":"6dfaaa60c89d3b9b3f38dc608335a3bb6cdcc12bfcbfb936f44c21c7deba51a1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b04f6e745236438b8fe60bd9eb","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101e15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069544.exe","SHA1Sum":"67171d244ac3dbb24e73b7c1c796416ab86b7127","SHA256Sum":"6d0392353e562c2235e18836547ac15bf57fcdb0cf2e7e439f2adf76e2cc5684","SHA512Sum":"95aa410a97557cf7551f0bece33db39715fbdeaeac3e463ef53f89b17f29f7947427c6888b5f8ac588493979d9cf2f87e756b1e461f93e1832aa2db5bc0e4bc6"}],"ComponentSizeInKB":1054,"CompsigList":["cp069544.compsig"],"FileList":["cp069544.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069544.exe","SHA1Sum":"67171d244ac3dbb24e73b7c1c796416ab86b7127","SHA256Sum":"6d0392353e562c2235e18836547ac15bf57fcdb0cf2e7e439f2adf76e2cc5684","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a556c13877764198a3876ee835","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.deb","SHA1Sum":"b54a19a87575d104fdc7de98caa8240e0655d74f","SHA256Sum":"0d2d86c766d9a23bba3ad9407c94dcb9563a8a647bec45705b7a564290aaea41","SHA512Sum":"10f605b40d1e453a9fa769ac1eb38cec2e37055ff80613d94c14003c09299ad74978adeba8d7e5073df9345dc7eaa1f150f50af653850c1c163743208f7e7268"}],"ComponentSizeInKB":4555,"CompsigList":["firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/CP067367.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/WLHCCBA0HPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067367.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067367.scexe"],"Name":"firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.deb","SHA1Sum":"b54a19a87575d104fdc7de98caa8240e0655d74f","SHA256Sum":"0d2d86c766d9a23bba3ad9407c94dcb9563a8a647bec45705b7a564290aaea41","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"2","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35950c763c2c4db988e2b4f7d5","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04","24.04","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070928.zip","SHA1Sum":"9964d765a1cfd648901210667e1f6a149f7c4e79","SHA256Sum":"25af35e08244731132bae11d3ceb3f1e2bff7c17b896fc39491c65873b10c392","SHA512Sum":"5edec19cb33b5ddc984cc2d8d4a110af3360a9f7fedaa9a6ce26071597c4f424a7442381e952814a22ac85f54eae758c86b17bef7c3a4d43499eb3018efc5c06"}],"ComponentSizeInKB":19131,"CompsigList":["CP070928.compsig"],"FileList":["/CP070928_BUILD_12.data","/CP070928.vmexe64","/CP070928.vmfile","/CP070928_VMw.zip","/CP070928.xml","/payload.json","/CP070928_VMw.zip/index.xml","/CP070928_VMw.zip/vendor-index.xml","/CP070928_VMw.zip/metadata.zip","/CP070928_VMw.zip/vib20/CP070928/HPE_bootbank_CP070928_HPD5.12-8.0.0.20613240.vib","/CP070928_VMw.zip/metadata.zip/vendor-index.xml","/CP070928_VMw.zip/metadata.zip/vmware.xml","/CP070928_VMw.zip/metadata.zip/vibs/CP070928--4962651068054852886.xml","/CP070928_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070928_HPD5.12-8.0.0.20613240.xml"],"Name":"CP070928.zip","SHA1Sum":"9964d765a1cfd648901210667e1f6a149f7c4e79","SHA256Sum":"25af35e08244731132bae11d3ceb3f1e2bff7c17b896fc39491c65873b10c392","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070928","Version":"HPD5.12-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26dfe3b1c0b845a1b44ad71f7c","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-netxtreme2-7.15.25-5.rhel9u7.x86_64.rpm","SHA1Sum":"beb3543a47452d76eec30603c456a8d08caad1c7","SHA256Sum":"6194a71f55bec7f1e70b9282021347f052a92a6eb0eb8694fa09b3f55b0d2db8","SHA512Sum":"7ca2622ec40a5b46568fe1e3547c64f14a62cffbada35df47d904dfd5d017023449e0977e55246dd6f64e15d17717782d60a6128db8d39c126653e4855f9ad15"}],"ComponentSizeInKB":8710,"CompsigList":["kmod-netxtreme2-7.15.25-5.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"Name":"kmod-netxtreme2-7.15.25-5.rhel9u7.x86_64.rpm","SHA1Sum":"beb3543a47452d76eec30603c456a8d08caad1c7","SHA256Sum":"6194a71f55bec7f1e70b9282021347f052a92a6eb0eb8694fa09b3f55b0d2db8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.25-9"},{"Checksum":[{"Filename":"kmod-netxtreme2-7.15.25-9.rhel9u6.x86_64.rpm","SHA1Sum":"793470fd918ad1fc76881b7dcac4d4ba6efbd74c","SHA256Sum":"118fe57cdcaf024d7ec25f7d4975b1d31197b22313bc41f5b4878cba6cc2ecfc","SHA512Sum":"b6d300aeadb37da306583895c8e7cf0636fecb4df7acc973f5a45f3ba508e1d14449cbc1779d3bd9ff8c24c88d45d602c4718018ba4000ec1209397694415eda"}],"ComponentSizeInKB":8656,"CompsigList":["kmod-netxtreme2-7.15.25-9.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"Name":"kmod-netxtreme2-7.15.25-9.rhel9u6.x86_64.rpm","SHA1Sum":"793470fd918ad1fc76881b7dcac4d4ba6efbd74c","SHA256Sum":"118fe57cdcaf024d7ec25f7d4975b1d31197b22313bc41f5b4878cba6cc2ecfc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.25-9"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ffeaf4cd1240485d9b81a6944b","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.rpm","SHA1Sum":"a6567e9778b860870dd16e299701db2f5afb3416","SHA256Sum":"46547ef3a5dc6e32c3419e9633bb5a1c9334564ac3886090e7953ff605006efa","SHA512Sum":"b654a405e0fcd995f190a36bfc4cdec4317de657cb36a460d90ba63e5b8d47aad010ff750c98b61d11a4b2b3a889146f8e0c4c2cd77122262a2a4169bbf5fdaf"}],"ComponentSizeInKB":8876,"CompsigList":["firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/CP071674.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071674.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071674.scexe"],"Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.rpm","SHA1Sum":"a6567e9778b860870dd16e299701db2f5afb3416","SHA256Sum":"46547ef3a5dc6e32c3419e9633bb5a1c9334564ac3886090e7953ff605006efa","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ecef034b6c30441abc03e163d0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070061.zip","SHA1Sum":"e2ae25f66e2f3ece746aea82be3cc27bc2ef7b13","SHA256Sum":"59ded6acc4d05daaca09761f08f36caee5e0869717668403a6fbb639dd1f2340","SHA512Sum":"32da9a3fe31f7eaf9db87aebc8e80ecb855997f4ebe4060a5519a544a4c69be48b0ec314f2837025d9f7ff8ead4c87c8267cfed298fdaac657a5907a3376e757"}],"ComponentSizeInKB":19444,"CompsigList":["CP070061.compsig"],"FileList":["/CP070061_BUILD_15.data","/CP070061.vmexe64","/CP070061.vmfile","/CP070061_VMw.zip","/CP070061.xml","/payload.json","/CP070061_VMw.zip/index.xml","/CP070061_VMw.zip/vendor-index.xml","/CP070061_VMw.zip/metadata.zip","/CP070061_VMw.zip/vib20/CP070061/HPE_bootbank_CP070061_HPD6.15-8.0.0.20613240.vib","/CP070061_VMw.zip/metadata.zip/vendor-index.xml","/CP070061_VMw.zip/metadata.zip/vmware.xml","/CP070061_VMw.zip/metadata.zip/vibs/CP070061--4504899403480904118.xml","/CP070061_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070061_HPD6.15-8.0.0.20613240.xml"],"Name":"CP070061.zip","SHA1Sum":"e2ae25f66e2f3ece746aea82be3cc27bc2ef7b13","SHA256Sum":"59ded6acc4d05daaca09761f08f36caee5e0869717668403a6fbb639dd1f2340","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070061","Version":"HPD6.15-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a22e7e8924b94faea523da1227","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071513.exe","SHA1Sum":"ec2afc724efd2209a64a74268cff47a836e1045e","SHA256Sum":"456dfba882953e8515c2f1c5658c270b4ff0b19d0852bae59851d3cc73d4150b","SHA512Sum":"7ee4f83d479755bde5a876470df0dca53231873cf1b3e68f9e011390faf17040f08c8345ba052fb36257446201c1651ef44f37fe01fc38670834cfb226846024"}],"ComponentSizeInKB":33442,"CompsigList":["cp071513_part1.compsig","cp071513_part2.compsig"],"FileList":["A42_4.04_04_02_2026.signed.flash","cp071513.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071513.exe","SHA1Sum":"ec2afc724efd2209a64a74268cff47a836e1045e","SHA256Sum":"456dfba882953e8515c2f1c5658c270b4ff0b19d0852bae59851d3cc73d4150b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_852c409fc394413ebf1c1f404e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070552.exe","SHA1Sum":"187e98078f18e3c86811d8e7ee97f1c50892074e","SHA256Sum":"e3793eac958efe16e5b74a13968ed95b94d7b2b12bef45eb24f298bb27de25fa","SHA512Sum":"c8ade1e4a7d35446e0dcf3edacab13f5df441c8a39d0f61797166db576fb92b761c13d2d6251687a02c977937f4193e62531933d453522f7e834962a985cd6a2"}],"ComponentSizeInKB":1687,"CompsigList":["cp070552.compsig"],"FileList":["cp070552.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","manifest_icea68.man","nicdrvr.dll"],"Name":"cp070552.exe","SHA1Sum":"187e98078f18e3c86811d8e7ee97f1c50892074e","SHA256Sum":"e3793eac958efe16e5b74a13968ed95b94d7b2b12bef45eb24f298bb27de25fa","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"TypeOfChange":"1","Version":"1.20.45.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e20ca1f61da14377a6bfc47ca7","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.deb","SHA1Sum":"590f18240e036bfb730ca957387e960f14155fb2","SHA256Sum":"c014de7ba2fa3ef975bd6d8ab530ecf1a78bb25235ce742f1bbb4d499a5e1c3e","SHA512Sum":"5ed5e17fe303415c3984c13052ad6c3402bb3be2a46c731613e552dcb00e5da59fd43881b9dd05fc8e4dce6f391002d1b67ee412760f939e971f0d2588d8d156"}],"ComponentSizeInKB":4331,"CompsigList":["firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/CP071734.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071734.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071734.scexe"],"Name":"firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.deb","SHA1Sum":"590f18240e036bfb730ca957387e960f14155fb2","SHA256Sum":"c014de7ba2fa3ef975bd6d8ab530ecf1a78bb25235ce742f1bbb4d499a5e1c3e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_52bc509801ad42b3a223b55a57","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072013.exe","SHA1Sum":"17f8abfb16e397bcac00a7104f02b47b736cf4f5","SHA256Sum":"9a8afa73edcc31b7bc3310763ef37b0d80b2aafe3d4de0ccb34df4d19a238611","SHA512Sum":"6cb6880110eed26ebf4f33b02755afd04990bf7ce91b941132458614844f2f6659c35af3db98cbe71c7ed2fdcb458b83f1d7b6ff93bedeb3cef6edc6fa750673"}],"ComponentSizeInKB":17771,"CompsigList":["cp072013.compsig"],"FileList":["A40_3.80_05_28_2026.signed.flash","cp072013.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072013.exe","SHA1Sum":"17f8abfb16e397bcac00a7104f02b47b736cf4f5","SHA256Sum":"9a8afa73edcc31b7bc3310763ef37b0d80b2aafe3d4de0ccb34df4d19a238611","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c2e8eb1d48849eb994fd1d003","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.rpm","SHA1Sum":"b1f870983196a7f4afc2e93ba97483bf7a493b2c","SHA256Sum":"e58a3003d00d470529ed7785b29f9697c2a6206f6f244918ad65636e44f637a4","SHA512Sum":"af592ba61ec2f81cb5eaa3528d67d6d41708acde795db027c907dd4debc60ffbebcaf504e703cb1cad06ee513cc3c084f80432f083fea1b7b432461b3f8580b4"}],"ComponentSizeInKB":2640,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/compat","./lib/modules/6.4.0-150600.21-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/block","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150600.21-default/updates/net","./lib/modules/6.4.0-150600.21-default/updates/net/9p","./lib/modules/6.4.0-150600.21-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150600.21-default/updates/net/rds","./lib/modules/6.4.0-150600.21-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.rpm","SHA1Sum":"b1f870983196a7f4afc2e93ba97483bf7a493b2c","SHA256Sum":"e58a3003d00d470529ed7785b29f9697c2a6206f6f244918ad65636e44f637a4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.rpm","SHA1Sum":"1f2080adde4e8ed6ecc2eab89377d2d45a550bd5","SHA256Sum":"e402e320efe5788cf96eb98e66d073aee69ff831b4675e96c029f5d0dcea12dd","SHA512Sum":"d82e698a8a57b222f4861edb3b9e98bb19d16da271336fd867a4b36aca1bdda87b6accaa8d85679306ab3c50f45e667b4e6c4742eb3c223fb16867343fc204d6"}],"ComponentSizeInKB":9993,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.8.84","./usr/share/doc/packages/libvma-9.8.84/CHANGES","./usr/share/doc/packages/libvma-9.8.84/README","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.rpm","SHA1Sum":"1f2080adde4e8ed6ecc2eab89377d2d45a550bd5","SHA256Sum":"e402e320efe5788cf96eb98e66d073aee69ff831b4675e96c029f5d0dcea12dd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d91eaeb1ccfd4d6893d490bfb7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-017797f12e_0HPD4-2.1_amd64.deb","SHA1Sum":"054f49920b24da13960abd6902cb79cc19e87c2b","SHA256Sum":"c125f3e09ae9ee804d27122d23d0310b03751ea749585503673cbf96eaf897ff","SHA512Sum":"e3375a2a2f1dae23b9f7af7312c84082fa399e238456bd5458cb5bba99ebf24d196b8049446b2d0965bdf338115b12e707894a43b8dbe4b97ca67c92140a2110"}],"ComponentSizeInKB":5242,"CompsigList":["firmware-hdd-017797f12e_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/CP071785.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/PCHFA2BP.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071785.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071785.scexe"],"Name":"firmware-hdd-017797f12e_0HPD4-2.1_amd64.deb","SHA1Sum":"054f49920b24da13960abd6902cb79cc19e87c2b","SHA256Sum":"c125f3e09ae9ee804d27122d23d0310b03751ea749585503673cbf96eaf897ff","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c21f4a1289bb45b79eecb199ad","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","SHA1Sum":"e0e96f283f0c4124acba8b2db0857916d92d2902","SHA256Sum":"9d791e64373b8d8fd4a0efea711dae81bc021f90392364e2162b0600d7334f31","SHA512Sum":"e694aebed2b3e6b6b3419cead44c162a917fbc0bad9fca80284dd82751a7e97abf7ed559ba75a75c5d13183437c875e69be5fbaf866f965284123a079bc92df6"}],"ComponentSizeInKB":5769,"CompsigList":["firmware-hdd-3496cc4743-HPG3-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/CP068841.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068841.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068841.scexe"],"Name":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","SHA1Sum":"e0e96f283f0c4124acba8b2db0857916d92d2902","SHA256Sum":"9d791e64373b8d8fd4a0efea711dae81bc021f90392364e2162b0600d7334f31","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_65c8ee31d6f74304bdfd954b3f","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.deb","SHA1Sum":"2ee3d4363bb1f09e0a73ec5acccc71ff9e7a6203","SHA256Sum":"5d4c4ea53ab1c977246d552a3af8d59a7c60ef184ece52be03cdf29430f2e9d8","SHA512Sum":"9ee840fe3baa7ad36a51041944e3da8d3eff7487a8b65b794da6e66cf45215b57d0314f439f148e08a0cb3caa351fc209487eb129bc22c3361bf47754c83c01f"}],"ComponentSizeInKB":4332,"CompsigList":["firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/CP071708.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071708.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071708.scexe"],"Name":"firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.deb","SHA1Sum":"2ee3d4363bb1f09e0a73ec5acccc71ff9e7a6203","SHA256Sum":"5d4c4ea53ab1c977246d552a3af8d59a7c60ef184ece52be03cdf29430f2e9d8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_51fb335eb60a46d2a486c067d3","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070800.zip","SHA1Sum":"0f6c128223d4a6b4bfdf233ea1494867eab33d2a","SHA256Sum":"f09352573166c97f95ef64355809cb82c639c7420b94865a028e8f3c0cbd2738","SHA512Sum":"5b8c85d6315dbaa99d412016ae2f3820aee9d82f7fa1dcb44070dfce2487bf8938a710f3c3ae04d2445a555470d67d5915b45b3b11d09fae1e3c2b1efb15832c"}],"ComponentSizeInKB":17771,"CompsigList":["cp070800.compsig"],"FileList":["/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip","/BCM_bootbank_storcli_007.3604.0000-1OEM.900.0.24755229.vib","/cp070800.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/vib20/storcli/BCM_bootbank_storcli_007.3604.0000-1OEM.900.0.24755229.vib","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vibs/storcli--6143981386257859090.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/bulletins/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.xml"],"Name":"cp070800.zip","SHA1Sum":"0f6c128223d4a6b4bfdf233ea1494867eab33d2a","SHA256Sum":"f09352573166c97f95ef64355809cb82c639c7420b94865a028e8f3c0cbd2738","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"storcli","Version":"007.3604.0000-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware9.1 (For Gen10P and Gen11  Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3604.0000-1OEM.900.0.24755229","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3604.0000-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f615e32ccf54da4a7ac306326","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","SHA1Sum":"c2ab12e5d3e976a0bcde54c2daeda418364bef8e","SHA256Sum":"0806423c340cc0b844c0d93e0e6ea3edc8eaef1b634f056ce0a3c4953f0b4ea8","SHA512Sum":"84115a3ddb3da4e7aed3eaff9c7a0d2f89cd1852cf817fb788d4f0fe8507283dea65c8c144a97d4b38ca99d440fccc31e2dea6a977a0062fdd2fe54902d81a39"}],"ComponentSizeInKB":5421,"CompsigList":["firmware-hdd-24384980ec-HPD2-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/CP068853.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068853.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068853.scexe"],"Name":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","SHA1Sum":"c2ab12e5d3e976a0bcde54c2daeda418364bef8e","SHA256Sum":"0806423c340cc0b844c0d93e0e6ea3edc8eaef1b634f056ce0a3c4953f0b4ea8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_87a0067ffcf54b28965bb0d063","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070966.zip","SHA1Sum":"ad7044a8ec4efb5736c7aca5921b6311e844b870","SHA256Sum":"1ef8dc9ca686c4edd626ed0b425d6d5fc1a8f7489b7108549ce6ee0f5a6dfa7a","SHA512Sum":"2210d8bf4714d32dbc213cbfe643194211b6afd0d1f98f0aee67ba2ad1ca6a69b4b1c53e31a6f367929543b8cabbf1ddefc65a3192cf2254532187b55cf16abd"}],"ComponentSizeInKB":19908,"CompsigList":["CP070966.compsig"],"FileList":["/CP070966_BUILD_2.data","/CP070966.vmexe64","/CP070966.vmfile","/CP070966_VMw.zip","/CP070966.xml","/payload.json","/CP070966_VMw.zip/index.xml","/CP070966_VMw.zip/vendor-index.xml","/CP070966_VMw.zip/metadata.zip","/CP070966_VMw.zip/vib20/CP070966/HPE_bootbank_CP070966_HPG1.2-8.0.0.20613240.vib","/CP070966_VMw.zip/metadata.zip/vendor-index.xml","/CP070966_VMw.zip/metadata.zip/vmware.xml","/CP070966_VMw.zip/metadata.zip/vibs/CP070966-1111787689071234695.xml","/CP070966_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070966_HPG1.2-8.0.0.20613240.xml"],"Name":"CP070966.zip","SHA1Sum":"ad7044a8ec4efb5736c7aca5921b6311e844b870","SHA256Sum":"1ef8dc9ca686c4edd626ed0b425d6d5fc1a8f7489b7108549ce6ee0f5a6dfa7a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070966","Version":"HPG1.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3775c0b14b84f01be3719f949","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","SHA1Sum":"84b6e1ab9ec2aa2f3679803d3a98b07af2adcf8f","SHA256Sum":"ff427c4e5df56b545d8ab5f392faf825b40c3009f4eb72e7f4ae79200700498e","SHA512Sum":"eb92bf6eaea66ceab8af4d12ff0f94ba10f66225cc3762a2e36cb674dbfe2894253f0d5e59468542db3b4c7074427f0ab49bb9005ddfb5d57cf8a6c562ce7e25"}],"ComponentSizeInKB":7202,"CompsigList":["firmware-hdd-035a863453-HPK5-11.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/CP068909.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068909.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068909.scexe"],"Name":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","SHA1Sum":"84b6e1ab9ec2aa2f3679803d3a98b07af2adcf8f","SHA256Sum":"ff427c4e5df56b545d8ab5f392faf825b40c3009f4eb72e7f4ae79200700498e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d4c8d4a771074416b3a178335c","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u31-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"28b44b923d2f6c480cd4f3808bd1c862de000f93","SHA256Sum":"847ad96f2efcbb8dec833fb5e27e00c642addc16959b456b1b6015975e1278ab","SHA512Sum":"55b8a2d6af83d8aacac699bd1a3976419bdf6acc3e24ad1d95d606b332248c077483546d818526f956c746ecfbd15bf45415a3a208e48c9f4daa9b45740a4d4f"}],"ComponentSizeInKB":11351,"CompsigList":["firmware-system-u31-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/CP071393.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/U31_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071393.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071393.scexe"],"Name":"firmware-system-u31-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"28b44b923d2f6c480cd4f3808bd1c862de000f93","SHA256Sum":"847ad96f2efcbb8dec833fb5e27e00c642addc16959b456b1b6015975e1278ab","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_84ac6434cc294c18836ffd3b37","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","11.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071992.exe","SHA1Sum":"55ea60534d445f17a725ee3a892547d8028d2fd8","SHA256Sum":"4a7d018fcf2eb4ae7d34cf45bcb8c8caf93545bb657937f4310f3ce001661838","SHA512Sum":"0d5a0d7b328ef6b4deeb7f45cb1748eb5a77419ceea3296e3c481e2d39ce867b6496eeaea5d9ac45c1534240d4dba68079d7b2e1eafa41eda94509a5532ec85f"}],"ComponentSizeInKB":705,"CompsigList":["cp071992.compsig"],"FileList":["cp071992.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/amddrtm.cat","pnp/amddrtm.dll","pnp/amddrtm.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"Name":"cp071992.exe","SHA1Sum":"55ea60534d445f17a725ee3a892547d8028d2fd8","SHA256Sum":"4a7d018fcf2eb4ae7d34cf45bcb8c8caf93545bb657937f4310f3ce001661838","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"8.3.14.329"}],"InstallationDependency":{},"Name":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows Server 2022 and 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a9fea24f197844038515593beb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A40","A43","A41","A46","A47","A42","A43","A43","A42","A48"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","SHA1Sum":"5e86971e665507a0bc0b75c0b1d7847c52dc69c8","SHA256Sum":"1395f9e09bfdfdb5e1649adaddae09959c043985775e9f84c69ac8eaa00def66","SHA512Sum":"8e7711615e673af533a1b429ed610e21e5e557b89d64705f80bd7af44b9d28a5975ac7a1de8275e896a6f714fef4d16d7a5e9a2d749e95c1b563b6059f2f0b72"}],"ComponentSizeInKB":6045,"CompsigList":["firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/CP068801.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068801.scexe"],"Name":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","SHA1Sum":"5e86971e665507a0bc0b75c0b1d7847c52dc69c8","SHA256Sum":"1395f9e09bfdfdb5e1649adaddae09959c043985775e9f84c69ac8eaa00def66","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_582f979e397949ae897a999f64","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071478.zip","SHA1Sum":"8771c746014c00a0c84e4e5a105bb1cf235a2282","SHA256Sum":"feff93aed2d4ba7fe9ff55fdae21d87611533ec8c4b31db46343ca057ba8fce3","SHA512Sum":"441d70bf0deaf011c0057bfdcd711daa953c5f8636ec6381efb74c6eea1e20116bc1783620e234410d72287aa254ef323f504a7ac8892d3fee32fb19d6878cdb"}],"ComponentSizeInKB":454,"CompsigList":["cp071478.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip","/cp071478.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_237.1.132.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_237.1.132.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtroce-6915120824006396274.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtnet--7046138232643143675.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.800.1.0.20613240.xml"],"Name":"cp071478.zip","SHA1Sum":"8771c746014c00a0c84e4e5a105bb1cf235a2282","SHA256Sum":"feff93aed2d4ba7fe9ff55fdae21d87611533ec8c4b31db46343ca057ba8fce3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2026.05.00","VibList":[{"Name":"bnxtroce","Version":"237.1.132.0-1OEM.800.1.0.20613240"},{"Name":"bnxtnet","Version":"237.1.132.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:237.1.232.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:237.1.132.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:237.1.132.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_94b749893a1348a3a5637f2097","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U46","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U32_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U32_3.66_04_01_2026.fwpkg","SHA1Sum":"6580e8384da87a20959fc2e5b20ec33d5dab1404","SHA256Sum":"246ee29686a72d0dab9a38d6b8a360f420b56a03e9a239e94fb469e1b3679926","SHA512Sum":"b2abd6cd1acf7f2fd7c86c9c156c0d679c59ec0818a9e57eb6afd048ae09f8785e5201e8798cf7b5d9da07357ba94d123ed078efc3b968ec780c4b2365665886"}],"ComponentSizeInKB":32826,"CompsigList":[],"FileList":["payload.json","U32_3.66_04_01_2026.signed.flash","U32_3.66_04_01_2026.xml"],"Name":"U32_3.66_04_01_2026.fwpkg","SHA1Sum":"6580e8384da87a20959fc2e5b20ec33d5dab1404","SHA256Sum":"246ee29686a72d0dab9a38d6b8a360f420b56a03e9a239e94fb469e1b3679926","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b26896ec99534afca86dc89ad3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_XXV4_OCP_4p91_NCSIwPLDMoMCTP_800214AC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4_OCP_4p91_NCSIwPLDMoMCTP_800214AC.fwpkg","SHA1Sum":"85ce5cdd9990543c9eabc1b6857b8c2c77a305e6","SHA256Sum":"8d6846bbb577d6919be7ee1e4c60cb65e61e71b630695dfceb312152f6f15b9f","SHA512Sum":"ff3a4692ec764a6a9e01d493ff7e116b6bef319c1274e145edb6dabe8e24b0ad795e7a4d006235e186d51670dd147803dd86cdc1e3a8dcb0a8608c99d7fada56"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXV4_OCP_4p91_NCSIwPLDMoMCTP_800214AC.HPb","HPE_E810_XXV4_OCP_4p91_NCSIwPLDMoMCTP_800214AC.xml","payload.json"],"Name":"HPE_E810_XXV4_OCP_4p91_NCSIwPLDMoMCTP_800214AC.fwpkg","SHA1Sum":"85ce5cdd9990543c9eabc1b6857b8c2c77a305e6","SHA256Sum":"8d6846bbb577d6919be7ee1e4c60cb65e61e71b630695dfceb312152f6f15b9f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df7b7b39b7ad460b81b893a773","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068637.exe","SHA1Sum":"4cdf59dcb6a950cd956af4e0e8ffff8bd953a0c4","SHA256Sum":"a8e84d46bac7e538737a7d41fb77cc8eb427ad8f35ffcecfeee63d6fbe5cc5db","SHA512Sum":"b876a4ef911a16a2cd2586962b82cb35a4432cf0fb2e88b787317a2f198bdf3ae05cc8f2e3909b81422cd463a55b78536a6b2e54c88b03fa870f11dc229f3c3f"}],"ComponentSizeInKB":7484,"CompsigList":["cp068637.compsig"],"FileList":["cp068637.xml","cpqsetup.exe","K503HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068637.exe","SHA1Sum":"4cdf59dcb6a950cd956af4e0e8ffff8bd953a0c4","SHA256Sum":"a8e84d46bac7e538737a7d41fb77cc8eb427ad8f35ffcecfeee63d6fbe5cc5db","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b227ec4622c46b1a335f928e0","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070545.exe","SHA1Sum":"fa95b6617eb73a5d2ec70aa2976dd74db67804bc","SHA256Sum":"efaba8fa4930aca865d167c3a8ced4fb63021c35e1adf7b9f634f28312421505","SHA512Sum":"c9a82ecb5f7e66a4d484059b340d940e3463b092e8cec5de4b16b749622119feb5532157165da6b2521b891cd2d66dee02e660d038cd7a5f17c59a5bcf586199"}],"ComponentSizeInKB":1217,"CompsigList":["cp070545.compsig"],"FileList":["cp070545.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070545.exe","SHA1Sum":"fa95b6617eb73a5d2ec70aa2976dd74db67804bc","SHA256Sum":"efaba8fa4930aca865d167c3a8ced4fb63021c35e1adf7b9f634f28312421505","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.24.41.0"}],"InstallationDependency":{},"Name":"HPE Intel i40ea Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d2decb02de64ec7a8a0c2bdb5","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","SHA1Sum":"0a6fa7ab81b025a3681bc05cac8ff5c3b3fe7c40","SHA256Sum":"2d218a9cbcc865581237ece8c2821acdffa82be92b319e7bb29618ebf9dbefce","SHA512Sum":"1367d5b1bdddff5c6364f58573288d87651949b8c1cb837adb99a002679f29ada8dc6dfa24e7be148ba7209ff07ac6cf9d526303d0dbab126d88a1ba7f341656"}],"ComponentSizeInKB":6090,"CompsigList":["firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/CP068926.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068926.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068926.scexe"],"Name":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","SHA1Sum":"0a6fa7ab81b025a3681bc05cac8ff5c3b3fe7c40","SHA256Sum":"2d218a9cbcc865581237ece8c2821acdffa82be92b319e7bb29618ebf9dbefce","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_241ac77ec9144d9c9a5d27ff91","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068647.exe","SHA1Sum":"14b5d32bc1127aeb7f9659270d0b02083e073c43","SHA256Sum":"c8783d5e235cd847f1aa33655a68ce15b2f833ce6d1e476e32a2013e28a6d070","SHA512Sum":"63a9b42a95c9f5a692b6b6ba9bea929d9c134df7bc923f0e390d7dc9778bf9ca9b6b4197a93ef03a15f3c0691a4f1c1173d80ee7f4a7381183f8360011fb01fc"}],"ComponentSizeInKB":3650,"CompsigList":["cp068647.compsig"],"FileList":["cp068647.xml","cpqsetup.exe","KARM5ALSHPD8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068647.exe","SHA1Sum":"14b5d32bc1127aeb7f9659270d0b02083e073c43","SHA256Sum":"c8783d5e235cd847f1aa33655a68ce15b2f833ce6d1e476e32a2013e28a6d070","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f2fede41d4c74f11919547b30c","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068741.exe","SHA1Sum":"c33b6c3f75b45be81225514353863e2932538021","SHA256Sum":"2bf5d7a2e607ddd05504feace561e49d3008b86a38b66549ec9c6433013c3730","SHA512Sum":"e17e3806d8b2a0043099e7e1750cfe17f2cdac4855f10d8739b409adeaec5e34ad64918f8899d32598184cadcbcbae8fe80fa87eabc67c0f63c9c27ec23a5a85"}],"ComponentSizeInKB":4444,"CompsigList":["cp068741.compsig"],"FileList":["cp068741.xml","cpqsetup.exe","HVLAeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068741.exe","SHA1Sum":"c33b6c3f75b45be81225514353863e2932538021","SHA256Sum":"2bf5d7a2e607ddd05504feace561e49d3008b86a38b66549ec9c6433013c3730","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a832d5a21a8241718cd4797643","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070976.zip","SHA1Sum":"213b224e0234e326ff054d868a39f608bd629a30","SHA256Sum":"87b69eecbc44a2517a209f6d81806ae767f03e63c27c4bea63ceddff13d72ac0","SHA512Sum":"5b6b13db33c9818fdf8cd191807519cdfc47fdabb608c176fd1add3d48f1bdb59c06d4041ac037a8d6d44c242489ee91518be3837e95387dc624f8c92df75551"}],"ComponentSizeInKB":20121,"CompsigList":["CP070976.compsig"],"FileList":["/CP070976_BUILD_1.data","/CP070976.vmexe64","/CP070976.vmfile","/CP070976_VMw.zip","/CP070976.xml","/payload.json","/CP070976_VMw.zip/index.xml","/CP070976_VMw.zip/vendor-index.xml","/CP070976_VMw.zip/metadata.zip","/CP070976_VMw.zip/vib20/CP070976/HPE_bootbank_CP070976_HPD6.1-8.0.0.20613240.vib","/CP070976_VMw.zip/metadata.zip/vendor-index.xml","/CP070976_VMw.zip/metadata.zip/vmware.xml","/CP070976_VMw.zip/metadata.zip/vibs/CP070976-8380625430916530490.xml","/CP070976_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070976_HPD6.1-8.0.0.20613240.xml"],"Name":"CP070976.zip","SHA1Sum":"213b224e0234e326ff054d868a39f608bd629a30","SHA256Sum":"87b69eecbc44a2517a209f6d81806ae767f03e63c27c4bea63ceddff13d72ac0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070976","Version":"HPD6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_08a2656ab1a144ed9a9cde7799","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304759434e54","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304759434e50","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-304759434e46","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-304759434e51","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-304759434e55","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304759434e48","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304759434e4b","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304759434e4c","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304759434e4e","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304759434e45","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3234-304758505154","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3438-304758505155","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Solidigm_S4X20_4IYYHPG4.fwpkg","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","SHA512Sum":"65b5d672dc5e33dba4d4431773c20352bb4d3ca60a3ed9951ef4dafb253a0d99dfe18ba04d5085db638231484e56df7860ed3f463d8f24b9504482da9770216d"}],"ComponentSizeInKB":1459,"CompsigList":[],"FileList":["payload.json","Solidigm_S4X20_4IYYHPG4.HPb","Solidigm_S4X20_4IYYHPG4.xml"],"Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GYCNT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK000960GYCNP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK001920GYCNF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK003840GYCNQ","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000240GYCNU","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000480GYCNH","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000960GYCNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK001920GYCNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK003840GYCNN","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK007680GYCNE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000240GXPQT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000480GXPQU","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8ae279136d1146d9a07e0ced51","SupportedDevices":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a47-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"2e9cf730e768cf0c6afbcf62be285028caeaa09d","SHA256Sum":"db7c0c12237ffd5d2b5478a9d539a1da7307f2a5a8305c14e38cfa44785b1e52","SHA512Sum":"45216853afdae3333228c55d457d39e7f06747257fd521f237367e9e6db7c0da8afb15a5cfff4dabaa82140bb2b45ff58bfa52a67095bc62679740fa6a2403ac"}],"ComponentSizeInKB":33239,"CompsigList":["firmware-system-a47-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a47-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/A47_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/CP071586.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071586.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071586.scexe"],"Name":"firmware-system-a47-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"2e9cf730e768cf0c6afbcf62be285028caeaa09d","SHA256Sum":"db7c0c12237ffd5d2b5478a9d539a1da7307f2a5a8305c14e38cfa44785b1e52","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a87bb893bc0c4ad4976f4fac8b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070964.zip","SHA1Sum":"22dbd9ae22256355e0905555b661ad6d586c1b67","SHA256Sum":"160160b8cfcb18becd032b90e717de391a2365c1c3e84d69de35b1178ed712c9","SHA512Sum":"80f0fbdf785adad5d84731f93725c437e0e7b0d838d7cca26c08b7b1202f112054484fa74f7be6e42d871abdf3dc0ffe7d0cd42a0c5f0d51db5a7d843bd4b17c"}],"ComponentSizeInKB":20359,"CompsigList":["CP070964.compsig"],"FileList":["/CP070964_BUILD_1.data","/CP070964.vmexe64","/CP070964.vmfile","/CP070964_VMw.zip","/CP070964.xml","/payload.json","/CP070964_VMw.zip/index.xml","/CP070964_VMw.zip/vendor-index.xml","/CP070964_VMw.zip/metadata.zip","/CP070964_VMw.zip/vib20/CP070964/HPE_bootbank_CP070964_HPD4.1-8.0.0.20613240.vib","/CP070964_VMw.zip/metadata.zip/vendor-index.xml","/CP070964_VMw.zip/metadata.zip/vmware.xml","/CP070964_VMw.zip/metadata.zip/vibs/CP070964-1531350772482773952.xml","/CP070964_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070964_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070964.zip","SHA1Sum":"22dbd9ae22256355e0905555b661ad6d586c1b67","SHA256Sum":"160160b8cfcb18becd032b90e717de391a2365c1c3e84d69de35b1178ed712c9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070964","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bea007ef1da4844977d8351bf","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp067481.zip","SHA1Sum":"3467ad2cd622f77d9a778c5a76a60b0b1422b6cb","SHA256Sum":"b69576b8f846b5fea2f9a27744160fb86ff7ad5063cb64aaf4c2bf7ee4d42f63","SHA512Sum":"007b20968e6bde7df47bc29b0c458101abb0792a3b8d82ff02f0318e4c90cd972d90d82b45adedd3db38d58d49d027075d5bf74bbe5e9082cc8c49a31ad3d226"}],"ComponentSizeInKB":120,"CompsigList":["cp067481.compsig"],"FileList":["/cp067481.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vib20/igbn/INT_bootbank_igbn_1.13.2.0-1OEM.900.0.24580437.vib","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vibs/igbn-831206253632276349.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.xml"],"Name":"cp067481.zip","SHA1Sum":"3467ad2cd622f77d9a778c5a76a60b0b1422b6cb","SHA256Sum":"b69576b8f846b5fea2f9a27744160fb86ff7ad5063cb64aaf4c2bf7ee4d42f63","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"igbn","Version":"1.13.2.0-1OEM.900.0.24580437"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eb551c6b6b314fbfa83789debb","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"tg3-kmp-default-3.139y_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"8de2253ae2024f7ffcce63dce888a5d4c3568410","SHA256Sum":"09ce44cfdc8d70724a09c5beac09de1189eec3d89ee0fb477e5c70ce1d0002fc","SHA512Sum":"621835a0df6e38a56045022040f535b96681d1fe290e21ab897ab365f18acd3206777ef3c08c44dc2ba4c4df747dab96a44c87f04b1fc1d19b77abc1ef4f3a5c"}],"ComponentSizeInKB":153,"CompsigList":["tg3-kmp-default-3.139y_k6.12.0_160000.5-2.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.139y_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"8de2253ae2024f7ffcce63dce888a5d4c3568410","SHA256Sum":"09ce44cfdc8d70724a09c5beac09de1189eec3d89ee0fb477e5c70ce1d0002fc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139y-2"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2cc7e4f0e7544c479ecf64b1ac","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U47","U40","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U72","U70","U68","A66","A66","03030202","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_UBM4_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"1.24"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM4_1.24_G.fwpkg","SHA1Sum":"f08bde255f56cfe95a4cb7cfb0c0c04754b9c24e","SHA256Sum":"21ad95f2ae46d3a5417a5bfa43832a676dde21e588070459bdfa5cf2778c62e1","SHA512Sum":"4634af67059c54186ad4758f7119cf0c4ec761d901f099794f59eb1a44723df92dcd71498a037d8e83b3ea5789c4301cafd659073d9851df915287a6141f39cc"}],"ComponentSizeInKB":61,"CompsigList":[],"FileList":["HPE_UBM4_1.24_G.HPb","HPE_UBM4_1.24_G.xml","payload.json"],"Name":"HPE_UBM4_1.24_G.fwpkg","SHA1Sum":"f08bde255f56cfe95a4cb7cfb0c0c04754b9c24e","SHA256Sum":"21ad95f2ae46d3a5417a5bfa43832a676dde21e588070459bdfa5cf2778c62e1","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901504000000"],"TypeOfChange":"1","Version":"1.24"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM4PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e14138c4c714237bcc8bfb333","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I45","A55","A55","A56","A56","U54","U54","U63","U58","U58","U59","U46","A42","U46","A43","A43","A42","U46","U69","U69","R11","U71","U71"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068890.zip","SHA1Sum":"cfe628395e4d23781d2cebf435d16caabec0f708","SHA256Sum":"1a932663c0b8363ec4ce5ae4e60ff603fe5395a304a7fe8f6b30e45b80ad83c2","SHA512Sum":"8bc2999c71cc40193cc5b09913c8b96320782556677df97b59a6c098210014f4b2efb6f7a28325b57afdb16a2e6513a2b078d1552c6a2853c2ebfb8e777cdd5f"}],"ComponentSizeInKB":17773,"CompsigList":["cp068890.compsig"],"FileList":["/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip","/BCM_bootbank_storcli_007.3604.0000-1OEM.900.0.24755229.vib","/cp068890.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/vib20/storcli/BCM_bootbank_storcli_007.3604.0000-1OEM.900.0.24755229.vib","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/vibs/storcli--6143981386257859090.xml","/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.zip/metadata.zip/bulletins/BCM-storcli_007.3604.0000-1OEM.900.0.24755229.xml"],"Name":"cp068890.zip","SHA1Sum":"cfe628395e4d23781d2cebf435d16caabec0f708","SHA256Sum":"1a932663c0b8363ec4ce5ae4e60ff603fe5395a304a7fe8f6b30e45b80ad83c2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"storcli","Version":"007.3604.0000-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3604.0000-1OEM.900.0.24755229","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3604.0000-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b56236f7b43f42acbc43a51ff5","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068750.exe","SHA1Sum":"cb2a334b3392f6bd6b292515073997ed671f96bc","SHA256Sum":"b0bf3e8493ec71a5447a25d723fe4e04a666eef512bd788a029018b32e7c1746","SHA512Sum":"d1e82e5a81ddf7759c17a6a15255c130a5a4c3e3227facba8c2f93862e58d3a697a942913f22dd0dd4b9e234d2f295a1c9450158f95860ed4e3f88eabc53b209"}],"ComponentSizeInKB":5212,"CompsigList":["cp068750.compsig"],"FileList":["cp068750.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2BP.rel","setup.dll"],"Name":"cp068750.exe","SHA1Sum":"cb2a334b3392f6bd6b292515073997ed671f96bc","SHA256Sum":"b0bf3e8493ec71a5447a25d723fe4e04a666eef512bd788a029018b32e7c1746","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20c192b14fdb4fb3a6a567aa63","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.deb","SHA1Sum":"9faf0a8333a2d7fcdb70dc891a79f2b49a063bff","SHA256Sum":"5664c7db5e1d6618a453a153f9523122667301d53220b9bb0092cb1b3b2d6ec4","SHA512Sum":"ff366250c0e788cf70f6846da7b4f1c8a3b5f82efbcfe4692aaafac3fbc99811aadcbb1051c8743bd09e0a3ec77c649714d354dad2085e4d7c157084b9484eea"}],"ComponentSizeInKB":4083,"CompsigList":["firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/CP071812.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071812.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071812.scexe"],"Name":"firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.deb","SHA1Sum":"9faf0a8333a2d7fcdb70dc891a79f2b49a063bff","SHA256Sum":"5664c7db5e1d6618a453a153f9523122667301d53220b9bb0092cb1b3b2d6ec4","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d39d718821fc45bd8a67807715","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"cp069596.exe","SHA1Sum":"b705b49ad24b0ac316df237c1975f14227b16910","SHA256Sum":"632968341a6337fbeebb4024a75965b644617e6e22c3a40d3b9af01ef29b49a1","SHA512Sum":"f3d9c569d86ba290b27e9e467d4a472c9312cb322da76a5445e64397a679dafdb893e280a521797ee311bfcb98fc2765c08b5d2de8b31a7d075955dd30e351f9"}],"ComponentSizeInKB":8840,"CompsigList":["cp069596.compsig"],"FileList":["cp051643.compsig","cp051643.zip","cp069596.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069596.exe","SHA1Sum":"b705b49ad24b0ac316df237c1975f14227b16910","SHA256Sum":"632968341a6337fbeebb4024a75965b644617e6e22c3a40d3b9af01ef29b49a1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_abd642129a204ef7a157ea1218","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"firmware-d6020_2.74-3.1_amd64.deb","SHA1Sum":"57637f6b2a10a61dc20c96222f4177d659bef727","SHA256Sum":"3b36ae370f784e0be89a171835c08ff8aba9b57f3a1f52a897b9fa3910868846","SHA512Sum":"7e032a942089db8b8763ec8b70f8f7fbef7d16f9a3433a2a95344e038c78146a7e1f5348dc6f6a0569c24e3f204371ceb027dd5d277889a1bfa8cc1642690b57"}],"ComponentSizeInKB":2298,"CompsigList":["firmware-d6020_2.74-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/CP072186.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072186.scexe","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072186.scexe"],"Name":"firmware-d6020_2.74-3.1_amd64.deb","SHA1Sum":"57637f6b2a10a61dc20c96222f4177d659bef727","SHA256Sum":"3b36ae370f784e0be89a171835c08ff8aba9b57f3a1f52a897b9fa3910868846","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a5fe4aa499a84a9992876e6e59","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ixgbevf-kmp-default-5.2.2_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"220d60e824eddab1a20bac1a0cd182af8b05d908","SHA256Sum":"5fa1293ba4f01e7d02f88675c21919e48acc6e5531e650177d397f6e82e75e49","SHA512Sum":"b5ac72ba412ca1c9b2254a7d3daa45f1b8d4306e2eeb1ef3a2f348e53520e67980c2d75f2dd9735a04c92cd0a10a9c98f3bc34af92e968d2b5fbf9c6250dc9db"}],"ComponentSizeInKB":99,"CompsigList":["ixgbevf-kmp-default-5.2.2_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbevf.ko","./usr/share/doc/packages/ixgbevf-kmp-default","./usr/share/doc/packages/ixgbevf-kmp-default/COPYING","./usr/share/doc/packages/ixgbevf-kmp-default/README","./usr/share/man/man7/ixgbevf.7.gz","./usr/share/pci.ids.d/pci.ids.ixgbevf-kmp-5.2.2","./usr/share/smartupdate/ixgbevf-kmp-default/component.xml"],"Name":"ixgbevf-kmp-default-5.2.2_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"220d60e824eddab1a20bac1a0cd182af8b05d908","SHA256Sum":"5fa1293ba4f01e7d02f88675c21919e48acc6e5531e650177d397f6e82e75e49","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0183d0f4"],"TypeOfChange":"1","Version":"5.2.2-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4428eb713ea64a80b9e7f49c0e","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067923.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"firmware-microservergen10plussps-05.01.05.103-1.1.x86_64.rpm","SHA1Sum":"26cf48d5ae15a4c4c325b0e0feceee1867f714a3","SHA256Sum":"41a547f0c668a9d627f010799cfd67c0a4c8bdca5e87ee2d6c7034eab4d31f20","SHA512Sum":"7fa056d8cee8eedce04777547cbb08eead69eabfab6c22274cda03d26678c1c2cd1516180cb292d78f0edfe0faa20abab25ce6fdc9298da9f575f63fced20b98"}],"ComponentSizeInKB":2128,"CompsigList":["firmware-microservergen10plussps-05.01.05.103-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/CP067926.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/cp067923.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/cp067923.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.103-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067926.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067926.scexe"],"Name":"firmware-microservergen10plussps-05.01.05.103-1.1.x86_64.rpm","SHA1Sum":"26cf48d5ae15a4c4c325b0e0feceee1867f714a3","SHA256Sum":"41a547f0c668a9d627f010799cfd67c0a4c8bdca5e87ee2d6c7034eab4d31f20","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd0baef48822461c917023c73e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U48"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"CP071763.zip","SHA1Sum":"d7d525f9fa1803a1b7b9856e3199e3ea27141806","SHA256Sum":"6aa5bfbcad67e10213e953a453bb0d0b7d9bdc9802620b2c3bcba6bb02d6df0b","SHA512Sum":"4cfdd95f9af9af18fd55db2966378258ad7aa3ac26f34eea7e69a7dd4a57e9ea1c50227a022b53041f3a6ce604045d444f11019e705e0d30f3234409074cfad5"}],"ComponentSizeInKB":24992,"CompsigList":["CP071763.compsig"],"FileList":["/CP071763_BUILD_1.data","/CP071763.vmexe64","/CP071763.vmfile","/CP071763_VMw.zip","/CP071763.xml","/payload.json","/CP071763_VMw.zip/index.xml","/CP071763_VMw.zip/vendor-index.xml","/CP071763_VMw.zip/metadata.zip","/CP071763_VMw.zip/vib20/CP071763/HPE_bootbank_CP071763_8.23.1-8.0.0.20613240.vib","/CP071763_VMw.zip/metadata.zip/vendor-index.xml","/CP071763_VMw.zip/metadata.zip/vmware.xml","/CP071763_VMw.zip/metadata.zip/vibs/CP071763-5125222314466472080.xml","/CP071763_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071763_8.23.1-8.0.0.20613240.xml"],"Name":"CP071763.zip","SHA1Sum":"d7d525f9fa1803a1b7b9856e3199e3ea27141806","SHA256Sum":"6aa5bfbcad67e10213e953a453bb0d0b7d9bdc9802620b2c3bcba6bb02d6df0b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23","VibList":[{"Name":"CP071763","Version":"8.23.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46e1db2d8433437d9b3010ccc1","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"firmware-fc-qlogic-2026.06.02-1.1.x86_64.rpm","SHA1Sum":"4b0acf988ed2b97c2dd9cc9fdbb1e642fae0d649","SHA256Sum":"147b65a699fb35c7857f2cd4e70d227653391ddade9c32e51be80d3c5f010377","SHA512Sum":"4cdc2aeda80431ba3fce8f6f977fd3ad249ead64def9a638684005ce7fb2a39e4108e89f14ee9e8ae352ec7833f8305f14f47f0593da3ce335892dfaa763b5ab"}],"ComponentSizeInKB":4206,"CompsigList":["firmware-fc-qlogic-2026.06.02-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/CP072109.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/bk020502.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/create_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libHBAAPI.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libHBAAPI.so.2","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libqlcoutil.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libqlsdm.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/mh021114.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.sub","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/remove_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072109.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072109.scexe"],"Name":"firmware-fc-qlogic-2026.06.02-1.1.x86_64.rpm","SHA1Sum":"4b0acf988ed2b97c2dd9cc9fdbb1e642fae0d649","SHA256Sum":"147b65a699fb35c7857f2cd4e70d227653391ddade9c32e51be80d3c5f010377","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e334d54ac552491a8f3de21454","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"35a82c57ceae8eff05147e87a97b5ee8542aaa96","SHA256Sum":"1b8e6481e3fcfd719b584671705191e1d97eaec8ac7d71de62208b10a4f60f59","SHA512Sum":"a9bf2c27a7e48e9c1bff9c4ba54b9385d1bfa3c4de143f40ef6b32facd3522b155ad5c454bf4e5161ebce340d13c0bb8f5c83d1ce857e7130ed29148bc433bb7"}],"ComponentSizeInKB":830,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"35a82c57ceae8eff05147e87a97b5ee8542aaa96","SHA256Sum":"1b8e6481e3fcfd719b584671705191e1d97eaec8ac7d71de62208b10a4f60f59","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Server Update 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c1cc044340dc471284b9556fd5","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-flq-1.25.0-3.1.x86_64.rpm","SHA1Sum":"61a30cc8b1001395585b61c651d32eabf1f2459c","SHA256Sum":"23d6287e1f16d67c28c42a98be3ec7b2714fa2aff9c6f181f503543040d4b803","SHA512Sum":"3ed3164cb97f56b70a7f5732f645cbcf4f2bc310a8c94d61013f93660467c020f7cc032e9db8e7d8e76815989db70b9bf38ecfd73c9aea7bab97be4f66d7d4dd"}],"ComponentSizeInKB":2198,"CompsigList":["firmware-nic-qlogic-flq-1.25.0-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/CP070122.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/CP070122.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/nic_fw/ql_hp_ah_mbi_8.65.23.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070122.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070122.scexe"],"Name":"firmware-nic-qlogic-flq-1.25.0-3.1.x86_64.rpm","SHA1Sum":"61a30cc8b1001395585b61c651d32eabf1f2459c","SHA256Sum":"23d6287e1f16d67c28c42a98be3ec7b2714fa2aff9c6f181f503543040d4b803","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"1.25.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f04dba6b67e482d812a5318c1","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070961.zip","SHA1Sum":"5ea3802c1de14ac33186af4c4d5b3c7c1c12981a","SHA256Sum":"0780c30ae6088fe290d2f25cbe659ac8282391aa4dd65c4c3d7b645bd2568dbf","SHA512Sum":"1142972fe3bb96403eea19e7068e6a4e2fd81f0c3d4750db4e15b4550ddc7ca6bfa41572f8f03711df49afc306406a33a33dc9cc37d118e1da120e906d214f36"}],"ComponentSizeInKB":19092,"CompsigList":["CP070961.compsig"],"FileList":["/CP070961_BUILD_2.data","/CP070961.vmexe64","/CP070961.vmfile","/CP070961_VMw.zip","/CP070961.xml","/payload.json","/CP070961_VMw.zip/index.xml","/CP070961_VMw.zip/vendor-index.xml","/CP070961_VMw.zip/metadata.zip","/CP070961_VMw.zip/vib20/CP070961/HPE_bootbank_CP070961_HPD3.2-8.0.0.20613240.vib","/CP070961_VMw.zip/metadata.zip/vendor-index.xml","/CP070961_VMw.zip/metadata.zip/vmware.xml","/CP070961_VMw.zip/metadata.zip/vibs/CP070961--8461313719284613183.xml","/CP070961_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070961_HPD3.2-8.0.0.20613240.xml"],"Name":"CP070961.zip","SHA1Sum":"5ea3802c1de14ac33186af4c4d5b3c7c1c12981a","SHA256Sum":"0780c30ae6088fe290d2f25cbe659ac8282391aa4dd65c4c3d7b645bd2568dbf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070961","Version":"HPD3.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_99d27394991345fd9a3b2b711d","SupportedDevices":["4d2340a5-304f-3330-3230-304a57444c42","4d2340a5-304f-3130-3630-304a57444c41","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3830-304a57444b56","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3430-304a57444b50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-4.8.0-2167.4.sles16.x86_64.rpm","SHA1Sum":"6f45f8f30bff19f9815e0a3364dada2c3d33173d","SHA256Sum":"297fa760b623962b5704587422841529dc5cd554eebe26b2e394b44b2cef20d2","SHA512Sum":"b8cdef9914de096cd042405e8445e54ad668dc709852917531d47a3465508ef51910a5ed55dc2cc9d05b8124707bb283816eb7ac562f22bc3de8d2cf99268bda"}],"ComponentSizeInKB":11381,"CompsigList":["amsd-4.8.0-2167.4.sles16.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/45","./usr/lib/.build-id/45/a5cfc4bd8a7f0474bd195766bb14652c86b39b","./usr/lib/.build-id/45/a5cfc4bd8a7f0474bd195766bb14652c86b39b.1","./usr/lib/.build-id/5f","./usr/lib/.build-id/5f/5f11a42aa217ed601012892198c6278bf27be4","./usr/lib/.build-id/5f/5f11a42aa217ed601012892198c6278bf27be4.1","./usr/lib/.build-id/71","./usr/lib/.build-id/71/e324ff219500bf06bfc27f06682aab3da2b020","./usr/lib/.build-id/71/e324ff219500bf06bfc27f06682aab3da2b020.1","./usr/lib/.build-id/80","./usr/lib/.build-id/80/2b9777f433f4cfcb0c6954310059483ddd108e","./usr/lib/.build-id/81","./usr/lib/.build-id/81/51e59a59741c7571f332d54e261388b47903a3","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/fb2aa8bac9ecc7b67d15a603f696d1c0237f56","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/6c979ae8dad5264e9b206bc0eccb11c406ec64","./usr/lib/.build-id/e0/6c979ae8dad5264e9b206bc0eccb11c406ec64.1","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/e38b5ff1c156fc2d7f63c117715efa22094fa3","./usr/lib/.build-id/fb/e38b5ff1c156fc2d7f63c117715efa22094fa3.1","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/2b189423a0a9d4830ee00c1ad597b2103f9fd8","./usr/lib/.build-id/fe/2b189423a0a9d4830ee00c1ad597b2103f9fd8.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-4.8.0-2167.4.sles16.x86_64.rpm","SHA1Sum":"6f45f8f30bff19f9815e0a3364dada2c3d33173d","SHA256Sum":"297fa760b623962b5704587422841529dc5cd554eebe26b2e394b44b2cef20d2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a005c3c3c5d4a07ad2f750ed1","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U58","U57","U65","U65","U62","A58","U69","U69","H11","I46","U68","U68","U68","U71","U66","U71","U72","U68","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"99286e28158f8a608611c44e9cea5adccb018f2e","SHA256Sum":"7146eeca3d69a3a5dfd00a7c59d5dd39f7b436d40786427d6f21d7b2aeb3fd44","SHA512Sum":"9c99cc8bfd6a5eb451ee701a0402bbf986a536985f1e1ca33cb86f1a6c2908d3eee9a720f9339ca36d962d15dce3c02a99e87e11c66ba57ecf318431993a854b"}],"ComponentSizeInKB":17706,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"99286e28158f8a608611c44e9cea5adccb018f2e","SHA256Sum":"7146eeca3d69a3a5dfd00a7c59d5dd39f7b436d40786427d6f21d7b2aeb3fd44","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.3.0-1"},{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"62a407db7513868467540809295f78e995bf9b7b","SHA256Sum":"5d731db6ac0001094e9699ed999c4c358fdf8d39e6bb531b6846ef16d5914a40","SHA512Sum":"9352a7010aee3e452e8bd6b805b15e997079e9442097c761444772be01e14f21b28675ac5fd3f713594ef2bde31d4689c66629bf5aab2d9b271e23bbd25298dd"}],"ComponentSizeInKB":17790,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"62a407db7513868467540809295f78e995bf9b7b","SHA256Sum":"5d731db6ac0001094e9699ed999c4c358fdf8d39e6bb531b6846ef16d5914a40","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.3.0-1"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6068c9da6ca24a958244554820","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068748.exe","SHA1Sum":"e23e814d9ce520c4e56d5ce5053f8652b366094e","SHA256Sum":"f3ece865a1af1c77d8571eaf8629954effa0bed8fcc26463849a85e4cba56f7d","SHA512Sum":"e1c74508e3f2a38b8c3ac32791259d31ec6d0cca411badd67243a38cab35e60fa468d1c05488a5104601cd35605fa946ffac2c333d334c8ea18fcf8dc5d16c30"}],"ComponentSizeInKB":4526,"CompsigList":["cp068748.compsig"],"FileList":["cp068748.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssASFD4.rel"],"Name":"cp068748.exe","SHA1Sum":"e23e814d9ce520c4e56d5ce5053f8652b366094e","SHA256Sum":"f3ece865a1af1c77d8571eaf8629954effa0bed8fcc26463849a85e4cba56f7d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e33b47e3812f43beab0d6c1014","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305058565255","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305058565252","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305058565254","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","SHA1Sum":"a623f578c663db154b05fc1512812ac47370b13f","SHA256Sum":"85216452bb60f9c10acbdddcad11748f412dbcbd90db437482b591d1deb573b3","SHA512Sum":"b6ee1f30dec529a0b9f1c5b4453c49a19ca804910d32ec7f9fab6062e4ba25d496ba296815d152f8bbf9dd240aef7276b6f354b055082401dd8234c3d415d7f4"}],"ComponentSizeInKB":1621,"CompsigList":[],"FileList":["Kioxia_PM7_KAPM7ALFHPD3.HPb","Kioxia_PM7_KAPM7ALFHPD3.xml","payload.json"],"Name":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","SHA1Sum":"a623f578c663db154b05fc1512812ac47370b13f","SHA256Sum":"85216452bb60f9c10acbdddcad11748f412dbcbd90db437482b591d1deb573b3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-305058565255","562340a5-304f-3330-3834-305058565252","562340a5-304f-3730-3638-305058565254"],"TypeOfChange":"2","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600PXVRU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXVRR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXVRT","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cfb3c1b576564b7fafa4c9bdcc","SupportedDevices":["562340a5-304f-3730-3638-305058565254","562340a5-304f-3330-3834-305058565252","4d2340a5-304f-3130-3630-305058565255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"2a1ec3b1d6f2edd1d14189d0c4d1aaa57d13defa","SHA256Sum":"4ada11d1c27d383f9e05e37fea05ba21725259b2caedd6d3813059659bec3cfd","SHA512Sum":"c636dd59af8c24888c85f1be5dcbaa966b18db741792cb3f7685775cec20212884fbe923cdef72718238be6ecad67dce4cc7ebdf949a2918221821b625046b21"}],"ComponentSizeInKB":5495,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/qla2xxx.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"2a1ec3b1d6f2edd1d14189d0c4d1aaa57d13defa","SHA256Sum":"4ada11d1c27d383f9e05e37fea05ba21725259b2caedd6d3813059659bec3cfd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_529426ce664b460680c774809b","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b594c4543","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b594c484c","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b594c484e","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b594c4542","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b594c4846","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b594c4848","Version":"HPK1"},{"DeviceName":"SKHynix-PE10X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE10X0_KPE10x0U3DK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b594c484b","Version":"HPK1"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE10X0_KPE10x0U3DK1.fwpkg","SHA1Sum":"88c4dfb1a9b10a9acce91cdbed993ce1740e38d2","SHA256Sum":"4a97d82fc7852e6d4cca15174ebadae6f5f10c748c3a0d1cfedece46d2f47d7e","SHA512Sum":"60bc60b70746bc7f94b1bf43decff97e803a8a96130d0dddfb6d932fda91881f713b07e2eb17bcf9d4f6d78e43ae2115a1088015ea4ef568c8e9f5b00156517b"}],"ComponentSizeInKB":9805,"CompsigList":[],"FileList":["payload.json","SKHynix_PE10X0_KPE10x0U3DK1.HPb","SKHynix_PE10X0_KPE10x0U3DK1.xml"],"Name":"SKHynix_PE10X0_KPE10x0U3DK1.fwpkg","SHA1Sum":"88c4dfb1a9b10a9acce91cdbed993ce1740e38d2","SHA256Sum":"4a97d82fc7852e6d4cca15174ebadae6f5f10c748c3a0d1cfedece46d2f47d7e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b594c4543","4d2340a5-304f-3330-3230-304b594c484c","4d2340a5-304f-3630-3430-304b594c484e","562340a5-304f-3130-3932-304b594c4542","562340a5-304f-3330-3834-304b594c4846","562340a5-304f-3730-3638-304b594c4848","562340a5-304f-3531-3336-304b594c484b"],"TypeOfChange":"1","Version":"HPK1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KYLEC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYLHL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYLHN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYLEB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYLHF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYLHH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYLHK","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3d2e90b3dab24c458b2fd74f4d","SupportedDevices":["4d2340a5-304f-3130-3630-304b594c4543","4d2340a5-304f-3330-3230-304b594c484c","4d2340a5-304f-3630-3430-304b594c484e","562340a5-304f-3130-3932-304b594c4542","562340a5-304f-3330-3834-304b594c4846","562340a5-304f-3730-3638-304b594c4848","562340a5-304f-3531-3336-304b594c484b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U40_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u40-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"410a5c3162d49c34ff86ed4c33a3c96b6430a7d2","SHA256Sum":"387bb528908c605fb5d86053b71a3c1b442b88d14ade7d2a9c9f2930ef28b81e","SHA512Sum":"3ff22b0d48bfc6173d339c66b78dcb597b44abf99e0973f7390af99b11439b13c58e7f2da877d7f870c0d24bb3d89eed56754668db38f8b395a0203fa12377b1"}],"ComponentSizeInKB":11577,"CompsigList":["firmware-system-u40-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/CP071417.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/U40_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071417.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071417.scexe"],"Name":"firmware-system-u40-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"410a5c3162d49c34ff86ed4c33a3c96b6430a7d2","SHA256Sum":"387bb528908c605fb5d86053b71a3c1b442b88d14ade7d2a9c9f2930ef28b81e","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fae10f7b4fc9422db7e25b5b56","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","9.0","8.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072195.exe","SHA1Sum":"def64366e45f9827a7e0fbf8ed527d424ebcf67b","SHA256Sum":"6c2813b7191b20603e750693aece22a0448012b2b0f3655ba39d27280c1c261b","SHA512Sum":"3a0d6cea29cad3d0b4b1cacb2b7d9fb2e97960d85b9d4b9e1b702f02f2fc6af15b979e8546e6421497835eeeeae49e9c755713640a375b550c13d97487a77766"}],"ComponentSizeInKB":2436,"CompsigList":["cp072195.compsig"],"FileList":["cp072195.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072195.exe","SHA1Sum":"def64366e45f9827a7e0fbf8ed527d424ebcf67b","SHA256Sum":"6c2813b7191b20603e750693aece22a0448012b2b0f3655ba39d27280c1c261b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_92472a6ca478452185dc8bf4d4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U45_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071439.exe","SHA1Sum":"91d5080b0fdaf3c8337fbce992f13987103e626d","SHA256Sum":"12221c64da8ce2df03786c79035bd9ccbf85ff92def3360cecd86afcbdef9b95","SHA512Sum":"47ca402a5780677dc5d5cac6b71f1dc371aa319cb6938dc2d6413b29f3e3a11cd7d8a29f027dcd57f0c6dd4372cbdda1471cb0d9fb1f21e32ae594c421833325"}],"ComponentSizeInKB":11351,"CompsigList":["cp071439.compsig"],"FileList":["cp071439.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_3.66_04_01_2026.signed.flash"],"Name":"cp071439.exe","SHA1Sum":"91d5080b0fdaf3c8337fbce992f13987103e626d","SHA256Sum":"12221c64da8ce2df03786c79035bd9ccbf85ff92def3360cecd86afcbdef9b95","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_434ed156958a44c1a222a3a044","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd_4.8.0-2167.4-ubuntu24_amd64.deb","SHA1Sum":"13f05ae2394c75e09265c4313f1030ce529c798c","SHA256Sum":"d76924d2ae2b8250bda4d1ef46ebd2da4504a870d3f1cefafcda9dac0b647faa","SHA512Sum":"16e4388ff1361484017622ead624fd241955b3f8ef1efe3f25c10f4f293cdee31f221dff23655d61edda4c73a2e5423c2e530c98ce5bdc911e78e37accba7ea9"}],"ComponentSizeInKB":8853,"CompsigList":["amsd_4.8.0-2167.4-ubuntu24_amd64.compsig"],"FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"Name":"amsd_4.8.0-2167.4-ubuntu24_amd64.deb","SHA1Sum":"13f05ae2394c75e09265c4313f1030ce529c798c","SHA256Sum":"d76924d2ae2b8250bda4d1ef46ebd2da4504a870d3f1cefafcda9dac0b647faa","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service for Ubuntu 24.04 LTS","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d73cf19f2cf740b9ae13aba15b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","A40","U30","U32","I42","U38","U38","U34","I43","A42","A43","A41","A42","A43","A42","A43","U46","U46","A55","A56","A55","A56","U54","U54","U54","U63","U63","U59","U58","U58","I45","I44","U69","U69","U68","U68","U68","U77","U62","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070636.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070639.exe","SHA1Sum":"f38244863bc18c58f90858e060ea40c01a3b9e22","SHA256Sum":"3db5de9eb23608b97a1af4a5ed2789d482d00bcf768a60b9c804f0d8004ca996","SHA512Sum":"b9f21a5ab4b7eb9572b5409343d04c7e296db8bfde9480e8e7c9314a4c5840a11160e62bfdb43970d0c5917187b5123eb168e4a9a74a09de6a7048d17fd7e960"}],"ComponentSizeInKB":2863,"CompsigList":["cp070639.compsig"],"FileList":["cp070636.compsig","cp070636.zip","cp070639.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070639.exe","SHA1Sum":"f38244863bc18c58f90858e060ea40c01a3b9e22","SHA256Sum":"3db5de9eb23608b97a1af4a5ed2789d482d00bcf768a60b9c804f0d8004ca996","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_880be3d5af1c4f8f99ac655773","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"cp068622.exe","SHA1Sum":"ad106791b45f10a79b7c526616713b7e295fab9a","SHA256Sum":"d4c113c5e17a27eaaca1febc2db02d7696c64c54b7717aa0b28e5a5786209e85","SHA512Sum":"07bd7aec8631d8dd711aac3926c7d500681b87b4593e94c2c6015186a79b2eb9c40d0c043f4458ee0c26b62e9b307bfb3194daeefa07a96089f32a2ba8f27435"}],"ComponentSizeInKB":3336,"CompsigList":["cp068622.compsig"],"FileList":["4IYRHPG7.bin","cp068622.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068622.exe","SHA1Sum":"ad106791b45f10a79b7c526616713b7e295fab9a","SHA256Sum":"d4c113c5e17a27eaaca1febc2db02d7696c64c54b7717aa0b28e5a5786209e85","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e4aa692ceed2495eac575e3869","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072196.exe","SHA1Sum":"68636e3a4e3eb762f03a7aeb21402d150a310672","SHA256Sum":"b2fbe0b233124652d05ae4be171c94ef3c8f9a4e9a26f5e4f46e02c867d38fb4","SHA512Sum":"aacee2222dd2767997bbdc6404d78656b7e445e6f631d224b518685cdda2883f496f2d4b99dd5dcc59ba2d54b82e4079bff3d2871608644ec7f158826934d830"}],"ComponentSizeInKB":2434,"CompsigList":["cp072196.compsig"],"FileList":["cp072196.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072196.exe","SHA1Sum":"68636e3a4e3eb762f03a7aeb21402d150a310672","SHA256Sum":"b2fbe0b233124652d05ae4be171c94ef3c8f9a4e9a26f5e4f46e02c867d38fb4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35cc99ba78f4424693990bb311","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.deb","SHA1Sum":"596673c08819ebfe58be4168e182f7957324fbed","SHA256Sum":"a84368307e278f821b417615d6b3390d0f920e98725b119916b0d92ce099e585","SHA512Sum":"eca90bf838e3ff3bc85a6b8a8c52b1c426fc293f52d518eac38b8f8e489d33cd53f908ef3738a793fa5cd187c65a361328e0b4a8167e8af19138925f8cc57db9"}],"ComponentSizeInKB":3464,"CompsigList":["firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/CP071706.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071706.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071706.scexe"],"Name":"firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.deb","SHA1Sum":"596673c08819ebfe58be4168e182f7957324fbed","SHA256Sum":"a84368307e278f821b417615d6b3390d0f920e98725b119916b0d92ce099e585","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c89b12216de74625b40198f036","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"CP072401.zip","SHA1Sum":"52d194d88ad6d3aa4654ea54462da36212b8b099","SHA256Sum":"b0d216705523d89226afb174d11f1636cbad0ef757486c442d7d5ebc82edc753","SHA512Sum":"6471698ac90464a3eba380e25fb070fa438ca47038f7e6449619c1f8a3f332aad56491f26a9200b8f91bdfa71d89a1aba9e8e55cac5b50bf6a4ece4d1d6c9104"}],"ComponentSizeInKB":30978,"CompsigList":["CP072401.compsig"],"FileList":["/CP072401.xml","/CP072401_VMw.zip","/payload.json","/CP072401.vmexe64","/CP072401.vmfile","/CP072401_VMw.zip/index.xml","/CP072401_VMw.zip/vendor-index.xml","/CP072401_VMw.zip/metadata.zip","/CP072401_VMw.zip/vib20/CP072401/HPE_bootbank_CP072401_1.0.0-8.0.0.21495797.vib","/CP072401_VMw.zip/metadata.zip/vendor-index.xml","/CP072401_VMw.zip/metadata.zip/vmware.xml","/CP072401_VMw.zip/metadata.zip/vibs/CP072401--8200363872583394572.xml","/CP072401_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072401_1.0.0-8.0.0.21495797.xml"],"Name":"CP072401.zip","SHA1Sum":"52d194d88ad6d3aa4654ea54462da36212b8b099","SHA256Sum":"b0d216705523d89226afb174d11f1636cbad0ef757486c442d7d5ebc82edc753","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.7","VibList":[{"Name":"CP072401","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_14ac2a9d89e8486c95d69b8f35","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp064345.zip","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","SHA512Sum":"7ca5575c6ceb44d4cfa0b3f2b0c2b59237288dd73a2a8fa25e32d6f6ee3ab8c08317222860d545830a6ebb13fa06ef37c095869238084fdf676ac1fcc8e6e2fb"}],"ComponentSizeInKB":1487,"CompsigList":["cp064345.compsig"],"FileList":["/cp064345.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp064345.zip","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_efd45025f131446c8a82a2b5fb","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","SHA1Sum":"5ceb4708a2a187507028a2a169407275529e130d","SHA256Sum":"fd181315d21147383bfa18d51645c0c546d24103952e849c627a118bd73d0222","SHA512Sum":"3d6ba8f8901888dd2cdbf00a502e7463d80ab3e81ee4590207f17b93721f96298b48df4c87f2fd0717c25d027040c9e1015ab42d54b27f3efdc8c1ada7935933"}],"ComponentSizeInKB":7025,"CompsigList":["firmware-hdd-017797f12e-HPD4-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/CP068851.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/PCHFA2BP.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068851.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068851.scexe"],"Name":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","SHA1Sum":"5ceb4708a2a187507028a2a169407275529e130d","SHA256Sum":"fd181315d21147383bfa18d51645c0c546d24103952e849c627a118bd73d0222","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_118afb87880649a9ac415ea8d3","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b460823f70_0HPG4-1.1_amd64.deb","SHA1Sum":"78bbdb2d11b1ce871f22a194281924ec0d42af71","SHA256Sum":"5e05e17611f34e78bd9789f075eadc595a73ab598de901e4db55ff1f12d510ba","SHA512Sum":"a6f4b67db00b533a526e8d0ebb5eb5e6e7c0d24fa35905326701a847c41d01ee80eded1d78e02dbc517394176cb778ba8cfa81a9a59d0eb2771d92e14a2c148b"}],"ComponentSizeInKB":3579,"CompsigList":["firmware-hdd-b460823f70_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/CP072241.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/M52008TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072241.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072241.scexe"],"Name":"firmware-hdd-b460823f70_0HPG4-1.1_amd64.deb","SHA1Sum":"78bbdb2d11b1ce871f22a194281924ec0d42af71","SHA256Sum":"5e05e17611f34e78bd9789f075eadc595a73ab598de901e4db55ff1f12d510ba","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40c1537c74174c718412997159","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U50_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U50_2.64_04_01_2026.fwpkg","SHA1Sum":"abe653d22fc1303f5f8248ded20d0abd0a582eb5","SHA256Sum":"58df9c0c317887bcae78f2927c7d082aff75d59ba7b1aad803a40271fa4d529f","SHA512Sum":"465fe3d7b023a543b6fec7fecc77ec1245a6ce57f3ddd9067e123230d54992228eb9933c7932badc0c68413956d6cc24f515db090320974a69d0fd41026ec079"}],"ComponentSizeInKB":32813,"CompsigList":[],"FileList":["payload.json","U50_2.64_04_01_2026.signed.flash","U50_2.64_04_01_2026.xml"],"Name":"U50_2.64_04_01_2026.fwpkg","SHA1Sum":"abe653d22fc1303f5f8248ded20d0abd0a582eb5","SHA256Sum":"58df9c0c317887bcae78f2927c7d082aff75d59ba7b1aad803a40271fa4d529f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_932cedc150084369b8a04bcba3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.65.23"}]},"Files":[{"Checksum":[{"Filename":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","SHA1Sum":"2268c3508c139333c4870aaa3af9950fbad98f6f","SHA256Sum":"c9337c1ebe6e0c2cd2f356fac61ccd3add24234e5d66b472af63ea47a3020136","SHA512Sum":"5802904261bac34a3d2c7dbd7fb386bdf87df8c77e14203a9247c54de7d295a4e01f970aebb1707a953755d1fd2d01a816591b45c127023b973976d795ec22fb"}],"ComponentSizeInKB":1784,"CompsigList":[],"FileList":["payload.json","ql_hp_ah_mbi_8.65.23_pldm.HPb","ql_hp_ah_mbi_8.65.23_pldm.xml"],"Name":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","SHA1Sum":"2268c3508c139333c4870aaa3af9950fbad98f6f","SHA256Sum":"c9337c1ebe6e0c2cd2f356fac61ccd3add24234e5d66b472af63ea47a3020136","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-80f0159002bd"],"TypeOfChange":"1","Version":"8.65.23"}],"InstallationDependency":{},"MinimumActiveVersion":"8.55.12","Name":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"NIC_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1b3da94c201b4cfdab6fc39046","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070927.zip","SHA1Sum":"78cce2149044a5d286c5252d4d0ede11465655b7","SHA256Sum":"39fd25460ec06238c3355f07ee48c408d141f7adf3876435cffe36fda4c8f3cb","SHA512Sum":"30d7c32cf17d4a434e8fb5d946d315b6db7a54f58fa5d08e0402bd6c2144e6e3c0a899064e23e33c36b2fced7a59cb3758aaae47e0d4cd7c421e35a50c5563cd"}],"ComponentSizeInKB":18578,"CompsigList":["CP070927.compsig"],"FileList":["/CP070927_BUILD_9.data","/CP070927.vmexe64","/CP070927.vmfile","/CP070927_VMw.zip","/CP070927.xml","/payload.json","/CP070927_VMw.zip/index.xml","/CP070927_VMw.zip/vendor-index.xml","/CP070927_VMw.zip/metadata.zip","/CP070927_VMw.zip/vib20/CP070927/HPE_bootbank_CP070927_HPD8.9-8.0.0.20613240.vib","/CP070927_VMw.zip/metadata.zip/vendor-index.xml","/CP070927_VMw.zip/metadata.zip/vmware.xml","/CP070927_VMw.zip/metadata.zip/vibs/CP070927-8422540308775341791.xml","/CP070927_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070927_HPD8.9-8.0.0.20613240.xml"],"Name":"CP070927.zip","SHA1Sum":"78cce2149044a5d286c5252d4d0ede11465655b7","SHA256Sum":"39fd25460ec06238c3355f07ee48c408d141f7adf3876435cffe36fda4c8f3cb","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070927","Version":"HPD8.9-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5087d4ec9b6646b484bd1f761c","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p91_NCSIwPLDMoMCTP_800214B2.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_OCP_4p91_NCSIwPLDMoMCTP_800214B2.fwpkg","SHA1Sum":"3ecbdc2c5453a9d008cd0c00727ab390c9f47a5c","SHA256Sum":"1b05b0a193391ae34868f1697e175465aa2edf28fa73e986b0d8e05a295c42e3","SHA512Sum":"503ebd990a87da5119cb15ca9192fd919c616ca9fe604acef1873baa18c8c63c042d352fc4b9deab59276765ffbb0a13c3f0dc9e947490684aeb498ae1ee4e8c"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_OCP_4p91_NCSIwPLDMoMCTP_800214B2.HPb","HPE_E810_XXVDA2_SD_OCP_4p91_NCSIwPLDMoMCTP_800214B2.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_OCP_4p91_NCSIwPLDMoMCTP_800214B2.fwpkg","SHA1Sum":"3ecbdc2c5453a9d008cd0c00727ab390c9f47a5c","SHA256Sum":"1b05b0a193391ae34868f1697e175465aa2edf28fa73e986b0d8e05a295c42e3","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f35925bfc51f45d1bd846ca78d","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U61_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071338.exe","SHA1Sum":"b6512674c82757e3adf6b816e9651378a5c88052","SHA256Sum":"46d2a8442266f467fcd3e21cf505e02d8a9f6e78c381af9ab131b3ff3fa6d048","SHA512Sum":"f3f6529b750af50b44a16604b4e26364808aeba1b9fc507a3d8a6bf52e624e68ee50f2a6ad8769beb20eb93859644dcdfc93eff5a18c59b80e0326dc082a4f12"}],"ComponentSizeInKB":17044,"CompsigList":["cp071338.compsig"],"FileList":["cp071338.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U61_2.64_04_01_2026.signed.flash"],"Name":"cp071338.exe","SHA1Sum":"b6512674c82757e3adf6b816e9651378a5c88052","SHA256Sum":"46d2a8442266f467fcd3e21cf505e02d8a9f6e78c381af9ab131b3ff3fa6d048","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_18cf7b92f6aa450d8c30767e27","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U30_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071350.exe","SHA1Sum":"20f247d2acbb40017139bdf1cae56ada4e71bda9","SHA256Sum":"63b3c3e4ac984387440134b31ccd879ae9b47aa2228c706acf24f3558959eecc","SHA512Sum":"b90f0d299e563b5f5a058cc4c4c5db6ffd04f7d65d765e915e9a8a1ec3db0375e8925cbc892e72b6f9a32555f0b8dc280a1aeeaf3815387b1ab86827568647a2"}],"ComponentSizeInKB":11582,"CompsigList":["cp071350.compsig"],"FileList":["cp071350.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_3.66_04_01_2026.signed.flash"],"Name":"cp071350.exe","SHA1Sum":"20f247d2acbb40017139bdf1cae56ada4e71bda9","SHA256Sum":"63b3c3e4ac984387440134b31ccd879ae9b47aa2228c706acf24f3558959eecc","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_815479edcb984ae9b04d8cd412","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.rpm","SHA1Sum":"0b573c9bf08f488d2b1aa6ac652b473655b35dd0","SHA256Sum":"a1ae7fbba20393aa2a953a3655912848de9318fd9f39f901a72b36855bd0d7ee","SHA512Sum":"b3df347841829902b047740590465012a835efb6875d4a8188a652ea39bb5eeef3eb8fbab8db85948a0ef2c3cfe0b22358a54265baf70ee89a35effbe3783acb"}],"ComponentSizeInKB":8500,"CompsigList":["firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/CP072373.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072373.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072373.scexe"],"Name":"firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.rpm","SHA1Sum":"0b573c9bf08f488d2b1aa6ac652b473655b35dd0","SHA256Sum":"a1ae7fbba20393aa2a953a3655912848de9318fd9f39f901a72b36855bd0d7ee","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a736a953ed24711b39f9e1fd7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U30","A42","U46","U32","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.20"}]},"Files":[{"Checksum":[{"Filename":"ilo5_320.fwpkg","SHA1Sum":"e473f7b5602e3a8740cd62a4b6f302ac9fb7946d","SHA256Sum":"381bde23c7c220224488a102eabf0e79fc62965f8a159a19c4f20127336f525c","SHA512Sum":"76addfe6bd77366788ae32bffe5ecb7acb7730a5f6450258e3b24c763759eb37c1d2e5781124cef0b142dee0c9e1006cef220baee6350c39c8dc7b791e3ae8d9"}],"ComponentSizeInKB":32800,"CompsigList":[],"FileList":["ilo5_320.bin","ilo5_320.xml","payload.json","readme.txt"],"Name":"ilo5_320.fwpkg","SHA1Sum":"e473f7b5602e3a8740cd62a4b6f302ac9fb7946d","SHA256Sum":"381bde23c7c220224488a102eabf0e79fc62965f8a159a19c4f20127336f525c","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cbdfacc417304aee952294a2bb","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-megaraid_sas-07.736.04.00_rhel10u1-1.x86_64.rpm","SHA1Sum":"3996918cc413bde4669bc5b580fe27c016685875","SHA256Sum":"93d4155aa3dd023b6b6df582a3e8dd4a3180a786e1ce1b54eb36907f6c5eb648","SHA512Sum":"2937aa427fdb3d10c9abad22e9b768ad937d1935ad4cb9fe51e4095e63289b2b758459b8fbe4b53eeae78c2e5577b1b1441f0a92fa98a4c272baee698c400193"}],"ComponentSizeInKB":136,"CompsigList":["kmod-megaraid_sas-07.736.04.00_rhel10u1-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.736.04.00_rhel10u1-1.x86_64.rpm","SHA1Sum":"3996918cc413bde4669bc5b580fe27c016685875","SHA256Sum":"93d4155aa3dd023b6b6df582a3e8dd4a3180a786e1ce1b54eb36907f6c5eb648","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.736.04.00"},{"Checksum":[{"Filename":"kmod-megaraid_sas-07.736.04.00_rhel10u0-1.x86_64.rpm","SHA1Sum":"6ca833727f01c9017ec5dad84cb53eb80b9a8fc3","SHA256Sum":"5d0a0b65a9b936d8d97890833b97ae3239f9a9f3e29b66b09f825ae6a1f8ad81","SHA512Sum":"705f127c2fc3b7bd064bc0a12421b94b7554e3f559b8efe711b29a9d80ad058d189070a704182ba4270105709160364bb91fa9d906f7281d372d9cf1987e31f2"}],"ComponentSizeInKB":137,"CompsigList":["kmod-megaraid_sas-07.736.04.00_rhel10u0-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/megaraid_sas","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.736.04.00_rhel10u0-1.x86_64.rpm","SHA1Sum":"6ca833727f01c9017ec5dad84cb53eb80b9a8fc3","SHA256Sum":"5d0a0b65a9b936d8d97890833b97ae3239f9a9f3e29b66b09f825ae6a1f8ad81","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.736.04.00"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_776acf16b7cb4651b5fbd3e97d","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U46","U30","U32","U61","A42","A43","A43","A42","U60","U63","U59","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072197.exe","SHA1Sum":"4f3c1706e671eca5447bc28dd60dbea806997b70","SHA256Sum":"45c26b2b5f7cacdd9e2498ed1fca668f1916ddf5b7967d0d3615cfda17a5e215","SHA512Sum":"5a23d0a9b7953708ebca71924a3f9f9c7af89dfb767e55444ae9425f93a9b9bc15d42dcdcbc08a768ca6d3cf6410ba096dc1f5496610babb48e4679d643c7c02"}],"ComponentSizeInKB":2432,"CompsigList":["cp072197.compsig"],"FileList":["cp072197.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072197.exe","SHA1Sum":"4f3c1706e671eca5447bc28dd60dbea806997b70","SHA256Sum":"45c26b2b5f7cacdd9e2498ed1fca668f1916ddf5b7967d0d3615cfda17a5e215","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d18aeb44d58a4095b4b031fc00","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP072363.zip","SHA1Sum":"3e7fe537fb48810e5934d16c74c40563b9c5d1c7","SHA256Sum":"56599bbe48d5834df4a54faf78f646c93a8a698b1af2e6a08755f5dcf072e598","SHA512Sum":"1743e42cb4ddb3782578a245ab672f6cf36202c627951177c06349f808f0b36e8a62eb9956774aff1fa67549bf2e29bf882e676e5adfa81a7b56bcae78974d83"}],"ComponentSizeInKB":19992,"CompsigList":["CP072363.compsig"],"FileList":["/CP072363_BUILD_1.data","/CP072363.vmexe64","/CP072363.vmfile","/CP072363_VMw.zip","/CP072363.xml","/payload.json","/CP072363_VMw.zip/index.xml","/CP072363_VMw.zip/vendor-index.xml","/CP072363_VMw.zip/metadata.zip","/CP072363_VMw.zip/vib20/CP072363/HPE_bootbank_CP072363_HPG6.1-8.0.0.20613240.vib","/CP072363_VMw.zip/metadata.zip/vendor-index.xml","/CP072363_VMw.zip/metadata.zip/vmware.xml","/CP072363_VMw.zip/metadata.zip/vibs/CP072363--9130305697406643904.xml","/CP072363_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072363_HPG6.1-8.0.0.20613240.xml"],"Name":"CP072363.zip","SHA1Sum":"3e7fe537fb48810e5934d16c74c40563b9c5d1c7","SHA256Sum":"56599bbe48d5834df4a54faf78f646c93a8a698b1af2e6a08755f5dcf072e598","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"2","Version":"HPG6","VibList":[{"Name":"CP072363","Version":"HPG6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07820cc09c7b4bd48f980864a4","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"IEGen10Plus_1.0.0.22.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"IEGen10Plus_1.0.0.22.fwpkg","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","SHA512Sum":"45b8552f3709e3e0db33df6d1128e37cdc3a1ed26a2f25fb448a7f26944931cdbb46862c72474b71ecabba001baa053da764a31fd005a2b27f36da3a49212aa5"}],"ComponentSizeInKB":8212,"CompsigList":[],"FileList":["IEGen10Plus_1.0.0.22.signed.bin","IEGen10Plus_1.0.0.22.xml","payload.json"],"Name":"IEGen10Plus_1.0.0.22.fwpkg","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5ba2fe62306d406aae00e29952","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10","U46"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072297.exe","SHA1Sum":"1aaf4257241cb74822dc73e76d07dc621ae44b29","SHA256Sum":"21680bd622eccbb1c56ec2cdaa5570096f58435e7a1c01c8818a74756ff23da8","SHA512Sum":"a7cb231dbd131c1c63fe0ff426623cf814bb6829e1d2be880f27e69aee3d308fd2a5ecd15667ba5ec9c62b8447ec3e7363031c1abdbff42509d362861e088ed3"}],"ComponentSizeInKB":604,"CompsigList":["cp072297.compsig"],"FileList":["cp072297.xml","cpqsetup.exe","installer.dll","pnp/","pnp/cannonlake-h.cat","pnp/CannonLake-HSystem.inf","pnp/CannonLake-HSystemThermal.inf","pnp/coffeelake.cat","pnp/CoffeelakeSystem.inf","pnp/null_heci.cat","pnp/NULL_HECISystem.inf"],"Name":"cp072297.exe","SHA1Sum":"1aaf4257241cb74822dc73e76d07dc621ae44b29","SHA256Sum":"21680bd622eccbb1c56ec2cdaa5570096f58435e7a1c01c8818a74756ff23da8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19928.8615"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_43d9225372234f6dad6a049c03","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":true,"SupportedProducts":["U43","U44","U48","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.deb","SHA1Sum":"4ee628e55a76e1f7b269deb02e23883c20a217d9","SHA256Sum":"3b7a7386c55673df68231e88b23c271c04c33bc6b5e1b2c04915768e220a38cd","SHA512Sum":"7e98d81dec46e228b9e2ac7ccb461693865f55352d5d6226add003fdac4f35b924faae0742b7d8a2859836d794c5441c89f304bd6b975c5812074f1b01c6cacd"}],"ComponentSizeInKB":4494,"CompsigList":["firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/CP071738.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071738.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071738.scexe"],"Name":"firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.deb","SHA1Sum":"4ee628e55a76e1f7b269deb02e23883c20a217d9","SHA256Sum":"3b7a7386c55673df68231e88b23c271c04c33bc6b5e1b2c04915768e220a38cd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_599cba23c07c4fe892105310eb","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","SHA1Sum":"131505ac84428aeb7be6742d622f1c3db69a4718","SHA256Sum":"511f2f81e35f78454da2a2142e130ea88428529872786bb6dac59bfcf415e2ec","SHA512Sum":"5e94bbb1d22235e9244e19b6dd1d71531a641628537ac896cb10fdc903d1778a3625435490ebca0d9265d35959244bdec394567d582370c072849738e10ba131"}],"ComponentSizeInKB":4951,"CompsigList":["firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/CP068824.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068824.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068824.scexe"],"Name":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","SHA1Sum":"131505ac84428aeb7be6742d622f1c3db69a4718","SHA256Sum":"511f2f81e35f78454da2a2142e130ea88428529872786bb6dac59bfcf415e2ec","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81f6023a6657428ba79e3359d8","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068738.exe","SHA1Sum":"1b9e4ef5501f65f52d33cc3376e9d2e874304bbc","SHA256Sum":"30b46d016872244b191c192e397b9525ed6969054abbf8faece08d074cab1c2d","SHA512Sum":"fbe006eb46acdf7bc06ca1cab553e80523ee5440ab34daee2ab6b5a6048e0c541c4ead492a33fa6a3845fe4eb939201135d458b47d0a07654c528c2600ecb39c"}],"ComponentSizeInKB":4254,"CompsigList":["cp068738.compsig"],"FileList":["cp068738.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPSD6.rel"],"Name":"cp068738.exe","SHA1Sum":"1b9e4ef5501f65f52d33cc3376e9d2e874304bbc","SHA256Sum":"30b46d016872244b191c192e397b9525ed6969054abbf8faece08d074cab1c2d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bb3daea065d04dc191baa120bf","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","SHA1Sum":"58931f3ff064143a8e6620e52e79e79a612830f1","SHA256Sum":"6fdfc86e270ceb9f9abf27852270a0946fe4c2258c57a5b1f3c24543d0d78f48","SHA512Sum":"9a7966d70d56966a9624029c6c1f1210b59349a36fa625f147257c0ce6badfe86846f24e09971226d32983e9ac3440e255ac198c491ce8221e79309f4910cc78"}],"ComponentSizeInKB":6072,"CompsigList":["firmware-hdd-020fc874ad-HPD3-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/CP068840.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068840.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068840.scexe"],"Name":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","SHA1Sum":"58931f3ff064143a8e6620e52e79e79a612830f1","SHA256Sum":"6fdfc86e270ceb9f9abf27852270a0946fe4c2258c57a5b1f3c24543d0d78f48","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46f9341a20c14989b9f4611fd9","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a46-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"4da91d6431aad75c7e2cbd313b7cc9132f3f71da","SHA256Sum":"92e2d7991931131cd3f87c7cf56b394d568b6a7864cbd4f6432dc8c6e6623488","SHA512Sum":"9db8dd331c0e88cbf3ff833c0e6b304f467cee71d4b5279b7a566f2d350682f90df7164123744b0ebefd616547fdc0406558adb38926520604a9ec639a167876"}],"ComponentSizeInKB":33254,"CompsigList":["firmware-system-a46-4.04_2026_04_02-1.1.x86_64_part1.compsig","firmware-system-a46-4.04_2026_04_02-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/A46_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/CP071518.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071518.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071518.scexe"],"Name":"firmware-system-a46-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"4da91d6431aad75c7e2cbd313b7cc9132f3f71da","SHA256Sum":"92e2d7991931131cd3f87c7cf56b394d568b6a7864cbd4f6432dc8c6e6623488","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f9594d6b3d794d5196464923ac","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"cp071764.exe","SHA1Sum":"4a8a628646fd6fc57be701ace356f9295a9638da","SHA256Sum":"e476357d28a610ab0b2225cc88ca0d8840f7b4c853cb06f1a65da0d2f0c537d5","SHA512Sum":"37aebdb0b1eff0f8b738e3a0e67a4e83c69529c3c0129cc93d4fe8be25d2033557664936061cc8f00394df9e83009a82fc43d7c318440989f4188ac6303dd25d"}],"ComponentSizeInKB":7600,"CompsigList":["cp071764.compsig"],"FileList":["cp071764.xml","cpqsetup.exe","HPE_luxor_8.23.bin.fw","payload.json","setup.dll"],"Name":"cp071764.exe","SHA1Sum":"4a8a628646fd6fc57be701ace356f9295a9638da","SHA256Sum":"e476357d28a610ab0b2225cc88ca0d8840f7b4c853cb06f1a65da0d2f0c537d5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_53dafc484b2b4a988ac636754c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-4.8.0-2167.6.rhel9.x86_64.rpm","SHA1Sum":"0510f8e53ee244e94bd79eb44c7de534d673875f","SHA256Sum":"6d5ac92e0bcd4fe4a29123a5525a2b0df963bb017ed2f334041e931b2a203dfb","SHA512Sum":"835246c93b35435a2727ecc2e1216a6028e57e5fb2a59f31e11c693680942b7dd2267a405021990badbcb072aad97bcbccf075e4502795e8381434df332eeab0"}],"ComponentSizeInKB":11691,"CompsigList":["amsd-4.8.0-2167.6.rhel9.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/79e8756b71e0c36cadaa7bee63eba1e1bac253","./usr/lib/.build-id/0b/79e8756b71e0c36cadaa7bee63eba1e1bac253.1","./usr/lib/.build-id/25","./usr/lib/.build-id/25/c5c946f74c7c1ed05d1fea57692ddb527df98e","./usr/lib/.build-id/25/c5c946f74c7c1ed05d1fea57692ddb527df98e.1","./usr/lib/.build-id/28","./usr/lib/.build-id/28/3bee758c1c07bf07748605e095ec4e9ad942a2","./usr/lib/.build-id/28/3bee758c1c07bf07748605e095ec4e9ad942a2.1","./usr/lib/.build-id/28/cc4139e12982e7694e91bc12768564f6f300e0","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/29a7eb509adc77e04ceaf7827e7d97342acc31","./usr/lib/.build-id/5e/29a7eb509adc77e04ceaf7827e7d97342acc31.1","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/c334e892152bef7b254a0c7804569a08c37c34","./usr/lib/.build-id/6f/c334e892152bef7b254a0c7804569a08c37c34.1","./usr/lib/.build-id/84","./usr/lib/.build-id/84/7ea91fbec6ac445a3a389c4c5eb06f1f754aef","./usr/lib/.build-id/de","./usr/lib/.build-id/de/b9cd2ed79eb62d8f76518f44871b4a4a1f5570","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/90ac2d145bb91f9287ace4af22f1cfc6c86fc0","./usr/lib/.build-id/fb/90ac2d145bb91f9287ace4af22f1cfc6c86fc0.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-4.8.0-2167.6.rhel9.x86_64.rpm","SHA1Sum":"0510f8e53ee244e94bd79eb44c7de534d673875f","SHA256Sum":"6d5ac92e0bcd4fe4a29123a5525a2b0df963bb017ed2f334041e931b2a203dfb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 9 Server","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f4d31e70846c49b4aea877e1f5","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U64","U58","U62","U57","U65","U65","A58","U69","U69","H11","U71","U72","U68","U68","U68","U66","U71","U68","I46","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-2c27a7a9a4_0HPD2-2.1_amd64.deb","SHA1Sum":"87607ebe6fef3ac1a41be627ae1921abbfe1bb79","SHA256Sum":"e56ae7ae395e324e9eab4ffdb9a01a954821694319483a04f0702c802cf453ec","SHA512Sum":"9864206fd20121800cd88639e53d4ee57799c7d2974878ff179156e5250670d6acac6cfb5c2b09e230e39fd72ed98b143d5c8bca830cae5d327c3462d7814895"}],"ComponentSizeInKB":4644,"CompsigList":["firmware-hdd-2c27a7a9a4_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/CP071715.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071715.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071715.scexe"],"Name":"firmware-hdd-2c27a7a9a4_0HPD2-2.1_amd64.deb","SHA1Sum":"87607ebe6fef3ac1a41be627ae1921abbfe1bb79","SHA256Sum":"e56ae7ae395e324e9eab4ffdb9a01a954821694319483a04f0702c802cf453ec","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a1330343e8d143e18f771bdc77","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"0fd38697b7f1220d20699dbed14b0280bfc796e2","SHA256Sum":"79988e3fd27742f8440169090c366e535b20f675e73113180dce908cd92ee3a2","SHA512Sum":"3b37c5f7380203820d1f167afc7422c59c814adca8062b67cc619c7654d1c65a8a36e0899a20bb2a227c16824811f291291e9b5b88be5856c6c061afd078525f"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"0fd38697b7f1220d20699dbed14b0280bfc796e2","SHA256Sum":"79988e3fd27742f8440169090c366e535b20f675e73113180dce908cd92ee3a2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900348"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_105eae77db3d48ce97184e7c75","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900348"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a43-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"234e908dbbf53bca8f703d0a7a5ed4bd2f16343d","SHA256Sum":"3c9c03dcad329c56c9112c73531f49362bc21ab992c0869e83625e5d45768043","SHA512Sum":"17b2f29181b673924412fadf2ba8a52025f23257ae3d01399bda949196e9ee36d981bd3de7887cf86fa8e4cafd34595db770970412777166b15882b2f80c0d62"}],"ComponentSizeInKB":33312,"CompsigList":["firmware-system-a43-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a43-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/A43_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/CP071519.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071519.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071519.scexe"],"Name":"firmware-system-a43-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"234e908dbbf53bca8f703d0a7a5ed4bd2f16343d","SHA256Sum":"3c9c03dcad329c56c9112c73531f49362bc21ab992c0869e83625e5d45768043","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a21add1c10a04672be3c7db1b1","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"CP070930.zip","SHA1Sum":"fdd29a7323831e070e0e63d9613e770b0b680983","SHA256Sum":"babd2771ae43192ee1724227c10c1638b2b3095d73701aefc0717e62a08409ea","SHA512Sum":"4005e3b2347b710e14694eb7949aa793ed298490e38e7505e2ed6f344c7d5ed0ac96820385c5ef606a4d4547ee09426a34929a1e1aeb72ffc3465c7653b84557"}],"ComponentSizeInKB":20448,"CompsigList":["CP070930.compsig"],"FileList":["/CP070930_BUILD_10.data","/CP070930.vmexe64","/CP070930.vmfile","/CP070930_VMw.zip","/CP070930.xml","/payload.json","/CP070930_VMw.zip/index.xml","/CP070930_VMw.zip/vendor-index.xml","/CP070930_VMw.zip/metadata.zip","/CP070930_VMw.zip/vib20/CP070930/HPE_bootbank_CP070930_GPK6.10-8.0.0.20613240.vib","/CP070930_VMw.zip/metadata.zip/vendor-index.xml","/CP070930_VMw.zip/metadata.zip/vmware.xml","/CP070930_VMw.zip/metadata.zip/vibs/CP070930--2659174081554699061.xml","/CP070930_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070930_GPK6.10-8.0.0.20613240.xml"],"Name":"CP070930.zip","SHA1Sum":"fdd29a7323831e070e0e63d9613e770b0b680983","SHA256Sum":"babd2771ae43192ee1724227c10c1638b2b3095d73701aefc0717e62a08409ea","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6","VibList":[{"Name":"CP070930","Version":"GPK6.10-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8b239f426abd48ba8fe1fc6f2d","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070206.exe","SHA1Sum":"30b92cb52bc7a9403c69ed8760ea367d8a09dd48","SHA256Sum":"192489a2cd5bd00df8d2d09c449d109d5a59d7a262ce8662f6eb338a22aa676e","SHA512Sum":"dade1466ad72044b032095889d5e1d37be7573787c6a5e75492d06a8dc854ba2c6ebe8e00234a41cd887bf35fd096abd70f19175d2a214bf3d93839bb1f53783"}],"ComponentSizeInKB":1227,"CompsigList":["cp070206.compsig"],"FileList":["cp070206.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"Name":"cp070206.exe","SHA1Sum":"30b92cb52bc7a9403c69ed8760ea367d8a09dd48","SHA256Sum":"192489a2cd5bd00df8d2d09c449d109d5a59d7a262ce8662f6eb338a22aa676e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"TypeOfChange":"0","Version":"6.0.0.0"}],"InstallationDependency":{},"Name":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":100,"RebootRequired":"no","SWKeys":[{"Name":"hponcfg.exe","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2e68cf7c5c944e8dac3a1c14e1","SupportedDevices":["a6b1a447-382a-5a4f-0e11-b2040e11b206","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I38","I32","A26","I41","I36","I31","I30","U34","U17","P79","U34","P85","P77","P89","A42","A40","A28","U46","U30","P89","P70","P73","A42","U46","U32","P89","P71","P73","A43","A43","A43","A41","P80","J05","U31","U20","U31","U20","J03","U36","P86","U15","U15","U43","U22","U41","P92","P72","J02","P78","J04","HPE ProLiant ML150 Gen10 Server","P95","U33","P99","U44","U23","O42","J10","P88","P74","P75","P75","P75","P75","P83","U51","U18","U18","U18","A47","A48","U40","U21","U50","U39","U47","U45","U25","U24","U24","U13","U37","U13","A46","U47","P94","A48","U38","U14","U38","U14","U48","O43","J06","U26","I36","I31","A45","U38","U38","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U38","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","Carbondale14","Carbondale14","U40","Carbondale14","U50","U39","U19","U46","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I40","I43","I39","I40","I45","I44","I42","I37","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U64","U58","R11","U65","U65","U65","H11","U69","A58","I15","P64","W04","U14","HP StorageWorks 1200 All-in-One Storage System","HP StorageWorks 600 All-in-One Storage System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072296.exe","SHA1Sum":"b72c5083e1512f9d0efdd40e9425ab00572b79c4","SHA256Sum":"14af75a627c6c328ae0723c0d78742fc63e96f5f58ebc2d38b6196276ea5ed97","SHA512Sum":"0bea4de19c456c87534244bdd760a40d9809e26ac61cd099047bf49af4e8ef4270e705e6492bac212b4ecdafdeb2b6587f937a0bb51d05fccbfed8b4184ce3f8"}],"ComponentSizeInKB":622,"CompsigList":["cp072296.compsig"],"FileList":["cp072296.xml","cpqsetup.exe","installer.dll","pnp/","pnp/IceLakeX.cat","pnp/IceLakeXSystem.inf","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Server_Common.cat","pnp/Server_CommonSystem.inf","pnp/Server_CommonSystemNorthpeak.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"Name":"cp072296.exe","SHA1Sum":"b72c5083e1512f9d0efdd40e9425ab00572b79c4","SHA256Sum":"14af75a627c6c328ae0723c0d78742fc63e96f5f58ebc2d38b6196276ea5ed97","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19879.8585"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_de4203a2dcc2446ea1d693aca4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10","U50"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59464646","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59464554","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59464555","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59464645","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59464550","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59464551","Version":"HPK2"},{"DeviceName":"SKHynix-PS10x0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PS10x0_KPS10x0U3DK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59464552","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PS10x0_KPS10x0U3DK2.fwpkg","SHA1Sum":"cad30730c0b85d575cc9ee0893c6611b7df1bf09","SHA256Sum":"e53a43bf535541a2b53adaf2d81abfa8c332c226b59efe94116ef9589f62e409","SHA512Sum":"a3e497f4a4858aab46789e5fdb91ac6d2b0489966df72623c1e924e6994e98b1eee7a0da3f78ed145fe2e0e12ec1ccff8dd0b0f234e293fb27d04efccdcb25d2"}],"ComponentSizeInKB":9813,"CompsigList":[],"FileList":["payload.json","SKHynix_PS10x0_KPS10x0U3DK2.HPb","SKHynix_PS10x0_KPS10x0U3DK2.xml"],"Name":"SKHynix_PS10x0_KPS10x0U3DK2.fwpkg","SHA1Sum":"cad30730c0b85d575cc9ee0893c6611b7df1bf09","SHA256Sum":"e53a43bf535541a2b53adaf2d81abfa8c332c226b59efe94116ef9589f62e409","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b59464646","4d2340a5-304f-3330-3230-304b59464554","4d2340a5-304f-3630-3430-304b59464555","562340a5-304f-3130-3932-304b59464645","562340a5-304f-3330-3834-304b59464550","562340a5-304f-3730-3638-304b59464551","562340a5-304f-3531-3336-304b59464552"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KYFFF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYFET","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYFEU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYFFE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYFEP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYFEQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYFER","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cf0615bbfbbd47ed854ab307d9","SupportedDevices":["562340a5-304f-3531-3336-304b59464552","562340a5-304f-3730-3638-304b59464551","562340a5-304f-3330-3834-304b59464550","562340a5-304f-3130-3932-304b59464645","4d2340a5-304f-3630-3430-304b59464555","4d2340a5-304f-3330-3230-304b59464554","4d2340a5-304f-3130-3630-304b59464646"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.deb","SHA1Sum":"df9472ba7b4f9e44d9f0b98332531ce65bd8d562","SHA256Sum":"89e9da848ecf0ba5d0bdd707aa5c80315caa54502cd4f6bad0757fd15d87713e","SHA512Sum":"0f8096d96687486b7f6e0f3efb5eb4c71781f860268f4333d5d339f6ac5f4798ae573a41e568ed3cd96e1b248105810a26aa422e4f1345419b74a4c5e2811938"}],"ComponentSizeInKB":4343,"CompsigList":["firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/CP071786.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/TAMG08acHPG5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071786.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071786.scexe"],"Name":"firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.deb","SHA1Sum":"df9472ba7b4f9e44d9f0b98332531ce65bd8d562","SHA256Sum":"89e9da848ecf0ba5d0bdd707aa5c80315caa54502cd4f6bad0757fd15d87713e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_86fc9e1b06834d7fbc14713d07","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070977.zip","SHA1Sum":"e7203020ce26e2ff576b6928d8db60e0d6f9912b","SHA256Sum":"5f78f1b7271189eac337f5faf32aca9389f714b097aaa20903c02d543dd35983","SHA512Sum":"f70ece9413fd69e1d5380e620abb7d78304d4ead6bdceb2f61c27730bed4b543a6fb996a4f863ef8cf2fef1b1870d1eed4b538b35b307a738b1b239e12754254"}],"ComponentSizeInKB":20411,"CompsigList":["CP070977.compsig"],"FileList":["/CP070977_BUILD_1.data","/CP070977.vmexe64","/CP070977.vmfile","/CP070977_VMw.zip","/CP070977.xml","/payload.json","/CP070977_VMw.zip/index.xml","/CP070977_VMw.zip/vendor-index.xml","/CP070977_VMw.zip/metadata.zip","/CP070977_VMw.zip/vib20/CP070977/HPE_bootbank_CP070977_HPD5.1-8.0.0.20613240.vib","/CP070977_VMw.zip/metadata.zip/vendor-index.xml","/CP070977_VMw.zip/metadata.zip/vmware.xml","/CP070977_VMw.zip/metadata.zip/vibs/CP070977--9212995779401950624.xml","/CP070977_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070977_HPD5.1-8.0.0.20613240.xml"],"Name":"CP070977.zip","SHA1Sum":"e7203020ce26e2ff576b6928d8db60e0d6f9912b","SHA256Sum":"5f78f1b7271189eac337f5faf32aca9389f714b097aaa20903c02d543dd35983","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070977","Version":"HPD5.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_315516f1ec37413aab0857e0a7","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-059b8654a6-HPG6-1.1.x86_64.rpm","SHA1Sum":"d3dc0e2377ba2b702b26f536318d4d3cf24654b2","SHA256Sum":"748c74713fb9759f8add5139e0fdac47546ec8daa5df6af870132a26a4ee4827","SHA512Sum":"63ee98ad11127ed419ad052b127b97f8908463549dff6a8625d5deb8b98e863be891ff5883b9742b9559774a6caba1e997e4b2d08871de2ce4d9820ef8f15421"}],"ComponentSizeInKB":6184,"CompsigList":["firmware-hdd-059b8654a6-HPG6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/CP072238.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/WLHCWBA0HPG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072238.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072238.scexe"],"Name":"firmware-hdd-059b8654a6-HPG6-1.1.x86_64.rpm","SHA1Sum":"d3dc0e2377ba2b702b26f536318d4d3cf24654b2","SHA256Sum":"748c74713fb9759f8add5139e0fdac47546ec8daa5df6af870132a26a4ee4827","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3782d66ff7504cc9b8caabdc77","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp072248.exe","SHA1Sum":"5cef178eb7081809aa985537adfd8d66062ee548","SHA256Sum":"234af8aed5b34928a6fbb1d6263c7ad2027df037c3defd592cce43b7818cecce","SHA512Sum":"6954af10f920ed98c949bdd97cc3d0ccb54e66dae07db686e7c01196b60954bef80cb0fd84e99b17e59cfb856c578ec12191b86a1e31ec317ee60df643b9e411"}],"ComponentSizeInKB":4325,"CompsigList":["cp072248.compsig"],"FileList":["cp072248.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLHCCBA0HPD5.rel"],"Name":"cp072248.exe","SHA1Sum":"5cef178eb7081809aa985537adfd8d66062ee548","SHA256Sum":"234af8aed5b34928a6fbb1d6263c7ad2027df037c3defd592cce43b7818cecce","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2183e35c540a4158ae2c29d455","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Files":[{"Checksum":[{"Filename":"cp071321.exe","SHA1Sum":"06656463282ab83ce9b4cb2ac65551dd634ccadd","SHA256Sum":"583eec777a41e327fa6d69f2e531df3bbc46b7441f6647b75d68f73f255a92c6","SHA512Sum":"a904f9337b81f60e9fefbce193bceaf056b7c920dfd20a0fade2a2386547f3b0b2c9167845f08b1eb9981d263d6129650a6432dd52e428175cef712832bad2ba"}],"ComponentSizeInKB":4467,"CompsigList":["cp071321.compsig"],"FileList":["cp071321.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.5-1/firmware/","elxflashStandalone-windows-14.4.731.5-1/firmware/B1447315.grp","elxflashStandalone-windows-14.4.731.5-1/firmware/P1447315.grp","elxflashStandalone-windows-14.4.731.5-1/win/","elxflashStandalone-windows-14.4.731.5-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.5-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.5-1/win/x64/","elxflashStandalone-windows-14.4.731.5-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.5-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.5-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp071321.exe","SHA1Sum":"06656463282ab83ce9b4cb2ac65551dd634ccadd","SHA256Sum":"583eec777a41e327fa6d69f2e531df3bbc46b7441f6647b75d68f73f255a92c6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_366a2fedcb0c4b1a941ad360ef","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070110.zip","SHA1Sum":"12aee9c789b6e34b2b2b499ae7c6d7c583196d9d","SHA256Sum":"2abaecd4753503aae231a7810c3dd7ad4d6400f864889b86c876166da27c92d4","SHA512Sum":"d2f3e8da7bc8a1610f8bd9c47f182fe648daa75feee43eb0039c0107f7a22903a82a231c474d7059e2b93df1d91efb35d9d72e35572b388252231d0c823c4139"}],"ComponentSizeInKB":5696,"CompsigList":["cp070110.compsig"],"FileList":["/cp070110.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070110.zip","SHA1Sum":"12aee9c789b6e34b2b2b499ae7c6d7c583196d9d","SHA256Sum":"2abaecd4753503aae231a7810c3dd7ad4d6400f864889b86c876166da27c92d4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b512340daadb4de6affb7413b3","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-igb-5.19.10-1.rhel10u1.x86_64.rpm","SHA1Sum":"0e9e3de0a64b8337cf7a286a1861cbcf8c920ba6","SHA256Sum":"751bee32d71eb07b744b930d283e9c10f7defc5cedab06af08e1823498e4d655","SHA512Sum":"5b8f23551b12199cf57825180c112a3f94895a2fdeea7c4076edb88a6ec7cd0ae39ffdfb8355e8d10818295e91caebf1e1926763024a50de73372c23ab5d0cf5"}],"ComponentSizeInKB":225,"CompsigList":["kmod-igb-5.19.10-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-igb.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/igb/igb.ko","./usr/share/doc/kmod-igb","./usr/share/doc/kmod-igb/COPYING","./usr/share/doc/kmod-igb/README","./usr/share/doc/kmod-igb/pci.updates","./usr/share/man/man7/igb.7.gz","./usr/share/smartupdate/kmod-igb/component.xml"],"Name":"kmod-igb-5.19.10-1.rhel10u1.x86_64.rpm","SHA1Sum":"0e9e3de0a64b8337cf7a286a1861cbcf8c920ba6","SHA256Sum":"751bee32d71eb07b744b930d283e9c10f7defc5cedab06af08e1823498e4d655","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca93656a5"],"TypeOfChange":"1","Version":"5.19.10-1"},{"Checksum":[{"Filename":"kmod-igb-5.19.10-1.rhel10u0.x86_64.rpm","SHA1Sum":"e118457dc4a9de936c7f9e69609a0ea1d758ca36","SHA256Sum":"04e4b86cb3ea3e267690de0cbc63a29f01529a670a03a44afd6f607e5a473539","SHA512Sum":"f3558edbd390b6aa8f02ee041f3649c962d318e037c58604364d2b2fd299a93bec8702141a86b3ce38a791172aebf0babbc335deaef5f97a6f1f080ff2a3d5fc"}],"ComponentSizeInKB":225,"CompsigList":["kmod-igb-5.19.10-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-igb.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/igb/igb.ko","./usr/share/doc/kmod-igb","./usr/share/doc/kmod-igb/COPYING","./usr/share/doc/kmod-igb/README","./usr/share/doc/kmod-igb/pci.updates","./usr/share/man/man7/igb.7.gz","./usr/share/smartupdate/kmod-igb/component.xml"],"Name":"kmod-igb-5.19.10-1.rhel10u0.x86_64.rpm","SHA1Sum":"e118457dc4a9de936c7f9e69609a0ea1d758ca36","SHA256Sum":"04e4b86cb3ea3e267690de0cbc63a29f01529a670a03a44afd6f607e5a473539","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca93656a5"],"TypeOfChange":"1","Version":"5.19.10-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcc49fb9f2b04da186a208f355","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"cp067915.exe","SHA1Sum":"ef4a193202048ddf8f25326f5bb64b7fcd538b64","SHA256Sum":"1820502b3a39c81c96869cea71b2e8dbb3d45a7035597de3356cb1c5c85605ae","SHA512Sum":"648808a82e31765fbf026b45011e086cd5214e72d6edd263b267f2b31e9a268b0ffda55901eb4d7588d79d1167a6b24d4d97601abbc84631d8650045093b6960"}],"ComponentSizeInKB":3680,"CompsigList":["cp067915.compsig"],"FileList":["cp067915.xml","cpqsetup.exe","Eaglescanyon-Release-0.39.bin.fw","payload.json","setup.dll"],"Name":"cp067915.exe","SHA1Sum":"ef4a193202048ddf8f25326f5bb64b7fcd538b64","SHA256Sum":"1820502b3a39c81c96869cea71b2e8dbb3d45a7035597de3356cb1c5c85605ae","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f1cd8f46c3014c16bdd1409b73","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp066052.zip","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","SHA512Sum":"b07ea3c41424b9dfedc83bb77b96fc3215150d650111bfdbc21083c8856c00943a3c5d2facbe0f07892ccdc58be9ab535ec1e1edc48b84422d234c7dc0506fbf"}],"ComponentSizeInKB":138,"CompsigList":["cp066052.compsig"],"FileList":["/cp066052.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vib20/igbn/INT_bootbank_igbn_1.12.2.0-1OEM.800.1.0.20613240.vib","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vmware.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vibs/igbn--4585876958502114762.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/bulletins/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240.xml"],"Name":"cp066052.zip","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"igbn","Version":"1.12.2.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_91eedfc8544c413bbd1e5e7e2f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U47_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u47-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"f2f573da66768088213919df6f7002bce20013d5","SHA256Sum":"226e3833b365c5f7add90c7e7d494dc0b59bba1ca654d940b8f6438702d5aa84","SHA512Sum":"b5bb78009e650f53db97aee991832dbbcde2f3ef79af40f4271da81371491250e552c3a9b93afec2a2ee9900056623f8ff437613633dd0bb526500ab83fbde7c"}],"ComponentSizeInKB":33274,"CompsigList":["firmware-system-u47-2.64_2026_04_01-1.1.x86_64_part1.compsig","firmware-system-u47-2.64_2026_04_01-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/CP071375.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/U47_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071375.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071375.scexe"],"Name":"firmware-system-u47-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"f2f573da66768088213919df6f7002bce20013d5","SHA256Sum":"226e3833b365c5f7add90c7e7d494dc0b59bba1ca654d940b8f6438702d5aa84","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aaf4727d0b984d6490cfdc73e5","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U47","U47"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE90X0_KPE9010SHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3936-305959585052","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE90X0_KPE9010SHPK2.fwpkg","SHA1Sum":"ebb12d8ca3ec4e2e8635eeb5cc70c219a8fe9e22","SHA256Sum":"a3b3bb908312a707ab1abcf9b1bcbd8786d20ec150d0e494d2bd064a6e5175bc","SHA512Sum":"aaa9908143998fb5c36eb5a6d606b4da2d6d74b14256d8a6ab2108b57ce80fae405ad45516201df37b9183d61d03f897483554575d61e35453752270d11daa49"}],"ComponentSizeInKB":1945,"CompsigList":[],"FileList":["payload.json","SKHynix_PE90X0_KPE9010SHPK2.HPb","SKHynix_PE90X0_KPE9010SHPK2.xml"],"Name":"SKHynix_PE90X0_KPE9010SHPK2.fwpkg","SHA1Sum":"ebb12d8ca3ec4e2e8635eeb5cc70c219a8fe9e22","SHA256Sum":"a3b3bb908312a707ab1abcf9b1bcbd8786d20ec150d0e494d2bd064a6e5175bc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3936-305959585052"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000960YYXPR","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000960YYXPR","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4924d8e0104a4e96a2206473e4","SupportedDevices":["562340a5-3052-3030-3936-305959585052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H10_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"H10_2.64_04_01_2026.fwpkg","SHA1Sum":"551ebb4fb8b01f9f913ebf150882c71b87884279","SHA256Sum":"dd142aa62ad775016ae8c5909ea670e01faf8cd19a092917dafcd2b1bfd6cac1","SHA512Sum":"45e3731eb589f3e6910cedb7e2aa1166c7c8de738aff995092667fa5674b57d42a80fc1fc0fcba71d43fc6e94226bc54c9caeaa463b2451d2d485a05577e68c6"}],"ComponentSizeInKB":32802,"CompsigList":[],"FileList":["H10_2.64_04_01_2026.signed.flash","H10_2.64_04_01_2026.xml","payload.json"],"Name":"H10_2.64_04_01_2026.fwpkg","SHA1Sum":"551ebb4fb8b01f9f913ebf150882c71b87884279","SHA256Sum":"dd142aa62ad775016ae8c5909ea670e01faf8cd19a092917dafcd2b1bfd6cac1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_402a046612f747db9b2fe968d1","SupportedDevices":[],"SupportedOperatingSystems":[],"SupportedPlatforms":false,"SupportedProducts":["H10","H10","H10","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-4.8.0-2167.4.rhel10.x86_64.rpm","SHA1Sum":"a6b326e266459d8165f16d0ce8dd6ec54828501a","SHA256Sum":"13ae6acec8774ae2a0c3081eb9d92a0e02eec9f9815dac8346916f6a2a34f5ac","SHA512Sum":"83e93ba92743f669313f14063b4a0cedc8f77ae59d3f7b33bcb70f9e719fc90e2208450fc6561d83a5d22bf0e6c4b2925afb01462bb58fed611739c69670b827"}],"ComponentSizeInKB":11684,"CompsigList":["amsd-4.8.0-2167.4.rhel10.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/0d","./usr/lib/.build-id/0d/aba0921c8e90aef212e6df9a27a5317a87727c","./usr/lib/.build-id/0d/aba0921c8e90aef212e6df9a27a5317a87727c.1","./usr/lib/.build-id/38","./usr/lib/.build-id/38/c8ab0ca9b98d3b607f5a08b7d647ad5228eafd","./usr/lib/.build-id/38/c8ab0ca9b98d3b607f5a08b7d647ad5228eafd.1","./usr/lib/.build-id/64","./usr/lib/.build-id/64/913aef3f20be8a3061ae20be22b168f67b951b","./usr/lib/.build-id/64/913aef3f20be8a3061ae20be22b168f67b951b.1","./usr/lib/.build-id/76","./usr/lib/.build-id/76/8806b8e4d24157bca836437d4894a4a3c72f13","./usr/lib/.build-id/99","./usr/lib/.build-id/99/cb2e7720190722e794e4e2d0a030b9b746fe4b","./usr/lib/.build-id/a4","./usr/lib/.build-id/a4/1086643cbfa6e65efd3fe5b61e7d1dc8932cbb","./usr/lib/.build-id/a4/1086643cbfa6e65efd3fe5b61e7d1dc8932cbb.1","./usr/lib/.build-id/a8","./usr/lib/.build-id/a8/4d8716d0378ceb35f2ad130e8ba6d2a76f3903","./usr/lib/.build-id/e2","./usr/lib/.build-id/e2/83a5d7c6c19f42754ce646ab6f5a6a58126a4d","./usr/lib/.build-id/e2/83a5d7c6c19f42754ce646ab6f5a6a58126a4d.1","./usr/lib/.build-id/ef","./usr/lib/.build-id/ef/f07b5e2c1260161a4fe235e9260dbb7785980e","./usr/lib/.build-id/ef/f07b5e2c1260161a4fe235e9260dbb7785980e.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-4.8.0-2167.4.rhel10.x86_64.rpm","SHA1Sum":"a6b326e266459d8165f16d0ce8dd6ec54828501a","SHA256Sum":"13ae6acec8774ae2a0c3081eb9d92a0e02eec9f9815dac8346916f6a2a34f5ac","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 10 Server","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_772b3d2d89b341b68ec79a2adf","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U64","U58","U62","U57","U65","U65","A58","U69","U69","H11","U71","U72","U68","U68","U68","U66","U71","U68","I46","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-6.8.0-7.linux.x86_64.rpm","SHA1Sum":"d3461ae6f3fd1016981b60c8f594705ad1d6decc","SHA256Sum":"b12795bca3133c787bbb7eb940a81d110d7de58ff754c793b4f5e157df111e78","SHA512Sum":"3f2c9ebc5dd207884fc2b8337932231f0dc9901593cdfd2079a0203574c83428bdf69c0ea85d13f7f496132bd35babb55103e7646d40cc8597ad6359139722af"}],"ComponentSizeInKB":9560,"CompsigList":["sut-6.8.0-7.linux.x86_64.compsig"],"FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/816b227696b91815670f9329216c873743e950","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/dd6c144b71ec6c92087c0772722846f86fdca9","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"Name":"sut-6.8.0-7.linux.x86_64.rpm","SHA1Sum":"d3461ae6f3fd1016981b60c8f594705ad1d6decc","SHA256Sum":"b12795bca3133c787bbb7eb940a81d110d7de58ff754c793b4f5e157df111e78","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.8.0.0"}],"InstallationDependency":{},"MinimumActiveVersion":"5.3.0","Name":"Integrated Smart Update Tools for Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d5dfe85083b430ba4ead2eb19","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U69","U71","U69","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U72","U77","R13","U70","H08","H10","U54","U54","U57","U65","H11","A58","A59","U66","U68","A66","U74","A66","U71","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.rpm","SHA1Sum":"b9477257f7218d2d3c9e4ecd46fe441bf87b42c9","SHA256Sum":"4bae72773bf49b15d5bb7d44909209a1095303b894acd68d58844d3c38ba311f","SHA512Sum":"bc1f18ad4f7acb37025079f6e60ada9c174d946fe802dfb493869777e24f3e237bdca5115814a1313938e511eddc57b0f2d2e1cc5450a24b5a658cb792eebea2"}],"ComponentSizeInKB":8260,"CompsigList":["firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/CP072359.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072359.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072359.scexe"],"Name":"firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.rpm","SHA1Sum":"b9477257f7218d2d3c9e4ecd46fe441bf87b42c9","SHA256Sum":"4bae72773bf49b15d5bb7d44909209a1095303b894acd68d58844d3c38ba311f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.25"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00cdb8b1a28e4c74a15f171a37","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","U36","U22","U41","A47","A48","U40","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U45","U25","U37","A42","U56","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070909.zip","SHA1Sum":"de0967bb06664cd4ced8a8481234bc7cffe2cdd2","SHA256Sum":"ead59706ea2540add06539a03007509499b86c5a180fe8e08cf96c2c96190cc2","SHA512Sum":"45a69f6224afcf579650e13368f7cb813d9b166ee7455c7f8d2b4358ea9d205965390c0b6faad69d15131ce3a32c21ae8bae7bc859d8476e65490889dc882120"}],"ComponentSizeInKB":27288,"CompsigList":["CP070909.compsig"],"FileList":["/CP070909_BUILD_4.data","/CP070909.vmexe64","/CP070909.vmfile","/CP070909_VMw.zip","/CP070909.xml","/payload.json","/CP070909_VMw.zip/index.xml","/CP070909_VMw.zip/vendor-index.xml","/CP070909_VMw.zip/metadata.zip","/CP070909_VMw.zip/vib20/CP070909/HPE_bootbank_CP070909_HPG3.4-8.0.0.20613240.vib","/CP070909_VMw.zip/metadata.zip/vendor-index.xml","/CP070909_VMw.zip/metadata.zip/vmware.xml","/CP070909_VMw.zip/metadata.zip/vibs/CP070909-3650224511072593898.xml","/CP070909_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070909_HPG3.4-8.0.0.20613240.xml"],"Name":"CP070909.zip","SHA1Sum":"de0967bb06664cd4ced8a8481234bc7cffe2cdd2","SHA256Sum":"ead59706ea2540add06539a03007509499b86c5a180fe8e08cf96c2c96190cc2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070909","Version":"HPG3.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a89f4e51e04040aa83574f9aa1","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a886842a99_0HPD2-2.1_amd64.deb","SHA1Sum":"6c11f5b7c6fe3efdc91d63a3109362442975eacd","SHA256Sum":"bcb20640b4f0187c6bf79acd6d95b442a6d2e7f445d24c59c9d3dc03f10296ef","SHA512Sum":"c829ed92bd63cfa66fdcb96a5a174c32ad8e3a34e4e53b5fcfa0989bb502ec4ec86a30b86570a8088e6672b6ab8bfaa866e6b7014212f583186524f86acea6c5"}],"ComponentSizeInKB":4661,"CompsigList":["firmware-hdd-a886842a99_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/CP071717.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071717.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071717.scexe"],"Name":"firmware-hdd-a886842a99_0HPD2-2.1_amd64.deb","SHA1Sum":"6c11f5b7c6fe3efdc91d63a3109362442975eacd","SHA256Sum":"bcb20640b4f0187c6bf79acd6d95b442a6d2e7f445d24c59c9d3dc03f10296ef","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_41ef5a5d28dc4b9b820f8e561e","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Files":[{"Checksum":[{"Filename":"cp070454.exe","SHA1Sum":"db4993be7b53c1f6191828fd80fac24bb7cb72de","SHA256Sum":"af44cbc044c00bea0b358ae2167d9cef325abde880e27868699950e43919016e","SHA512Sum":"c621b47955c65540cde8ba80eb1306aa6a3d42e9f06186a075d4d3cc39e52f3360abc989ff8b64e5e6b4a5cecefed49e76b8475f302192aea3574abbf2f1445a"}],"ComponentSizeInKB":9654,"CompsigList":["cp070454.compsig"],"FileList":["661SFP.cfg","BootIMG.FLB","cp070454.xml","cpqsetup.exe","FVL_25G_Adapter_VPD_MAP.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","nvmupdatew64e.exe","payload.json","payload_version.txt","XXV710DA2_9p20_CFGID12p0_OEMGEN.bin"],"Name":"cp070454.exe","SHA1Sum":"db4993be7b53c1f6191828fd80fac24bb7cb72de","SHA256Sum":"af44cbc044c00bea0b358ae2167d9cef325abde880e27868699950e43919016e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"InstallationDependency":{},"Name":"HPE Edgeline 661SFP28 NIC Firmware Pack for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c28f2857d33846b1a33081f250","SupportedDevices":["a6b1a447-382a-5a4f-8086-158b15900253"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H08_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"H08_3.66_04_01_2026.fwpkg","SHA1Sum":"647708e5285a4d9f1c492657a2eafd2259445bfd","SHA256Sum":"1d6d9e64a5053d13c75eac1fbf97c0e5042fc0753b11d2a250632ba8ebe096b6","SHA512Sum":"6af08369188352cf548ecaa3dfc11a22819ac3f0bf7df29aef3c7758bae1d3a24e7a620bcacc5008f6e5da91fc60a8169b907a8e14ac2f0316474458abdbb96b"}],"ComponentSizeInKB":32801,"CompsigList":[],"FileList":["H08_3.66_04_01_2026.signed.flash","H08_3.66_04_01_2026.xml","payload.json"],"Name":"H08_3.66_04_01_2026.fwpkg","SHA1Sum":"647708e5285a4d9f1c492657a2eafd2259445bfd","SHA256Sum":"1d6d9e64a5053d13c75eac1fbf97c0e5042fc0753b11d2a250632ba8ebe096b6","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_243e8bd817c345b0b82cb96dcb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","6.7","6.5","6.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","SHA1Sum":"515b9ebcc8c5757af109f083e33fb11bf9893f05","SHA256Sum":"67284f4ff7c7f67c7f7977ab7f4a3561e40dc36633e57443400935af765847d6","SHA512Sum":"302268edc3cbc18e1a14c3de472bf1de61bcff54e996e19385555964670560552d64e575c801df41300490d8be952dfcd6011b0ae04dd3e75f3c76a7bd8e9681"}],"ComponentSizeInKB":6096,"CompsigList":["firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/CP068803.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068803.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068803.scexe"],"Name":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","SHA1Sum":"515b9ebcc8c5757af109f083e33fb11bf9893f05","SHA256Sum":"67284f4ff7c7f67c7f7977ab7f4a3561e40dc36633e57443400935af765847d6","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c412afec4b864fbe9252ae577a","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3231-3030-304a575a4842"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070949.zip","SHA1Sum":"c67a8f5fce1ab7e316ce45248bcc8a7cdfa9c69a","SHA256Sum":"1b1c5b053a10fb0d701334122991f6b2367cf18ba1e1dd49d7eefcd564e0a949","SHA512Sum":"d6977f48ce34e0bb7efecb256668ef5ca6d9c1e6fa34041e06fc31d59924de81522e622f0e35e16ff01e00191de2276bb6eb02e18c4b343ee0be609c414f14b1"}],"ComponentSizeInKB":17643,"CompsigList":["CP070949.compsig"],"FileList":["/CP070949_BUILD_3.data","/CP070949.vmexe64","/CP070949.vmfile","/CP070949_VMw.zip","/CP070949.xml","/payload.json","/CP070949_VMw.zip/index.xml","/CP070949_VMw.zip/vendor-index.xml","/CP070949_VMw.zip/metadata.zip","/CP070949_VMw.zip/vib20/CP070949/HPE_bootbank_CP070949_HPD9.3-8.0.0.20613240.vib","/CP070949_VMw.zip/metadata.zip/vendor-index.xml","/CP070949_VMw.zip/metadata.zip/vmware.xml","/CP070949_VMw.zip/metadata.zip/vibs/CP070949--7028351664280872651.xml","/CP070949_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070949_HPD9.3-8.0.0.20613240.xml"],"Name":"CP070949.zip","SHA1Sum":"c67a8f5fce1ab7e316ce45248bcc8a7cdfa9c69a","SHA256Sum":"1b1c5b053a10fb0d701334122991f6b2367cf18ba1e1dd49d7eefcd564e0a949","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070949","Version":"HPD9.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e72ec704d8c548e18aafd628ed","SupportedDevices":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.deb","SHA1Sum":"4732aed595a567c0187491fa2de7bb7a9ce31343","SHA256Sum":"9132f1dde3341fd8f67badbe06d1d840d4f6ed25e948b5c9a78b441b91f3926a","SHA512Sum":"ae3ad94a5b262dec517b29ec2aeb048167652317d42563f008b472c5791e00201f48c05d5ba36f226340c590c0ccf7535bc8b539e36b0d6df655b08b1be3de93"}],"ComponentSizeInKB":7096,"CompsigList":["firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/CP071802.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071802.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071802.scexe"],"Name":"firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.deb","SHA1Sum":"4732aed595a567c0187491fa2de7bb7a9ce31343","SHA256Sum":"9132f1dde3341fd8f67badbe06d1d840d4f6ed25e948b5c9a78b441b91f3926a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e6673dfaae74441d91bb9c137a","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072212.exe","SHA1Sum":"3b589e3e33d927ecd75a2e4e7e294bbf4cf20700","SHA256Sum":"70bbfa8f11d1bb50cb55de904e7e22f193447c8898c5565b2f04f0dfbd835e1b","SHA512Sum":"ee1e9968ba030dfe4e8901ad07226f9e3d2c2b3a83291f5363ea6974fdbdb8c6e360173e633319d9022b2adb8aea16883984964344cc5530abda91423de53972"}],"ComponentSizeInKB":560,"CompsigList":["cp072212.compsig"],"FileList":["cp072212.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"Name":"cp072212.exe","SHA1Sum":"3b589e3e33d927ecd75a2e4e7e294bbf4cf20700","SHA256Sum":"70bbfa8f11d1bb50cb55de904e7e22f193447c8898c5565b2f04f0dfbd835e1b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"InstallationDependency":{},"Name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2016 and Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_746ec6dfe8134081a8df73be4e","SupportedDevices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I44","A47","A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ixgbe-6.3.4-1.rhel10u0.x86_64.rpm","SHA1Sum":"588ee1ffb3f8336c05ca63f3597fffbce1d01dee","SHA256Sum":"71bd1a565396e23ba3e3c54fbf08041febb5a6063f5503072688da5f9a84e4cd","SHA512Sum":"86beaa94f71f20d34ab8421169e6b2cb33776e51a143ffdfddd0002284b8c43af0d7b796b48079c90271a1902457555e05fd6f8dd6877ce23227f316748a4a5a"}],"ComponentSizeInKB":437,"CompsigList":["kmod-ixgbe-6.3.4-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbe.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/ixgbe/ixgbe.ko","./usr/share/doc/kmod-ixgbe","./usr/share/doc/kmod-ixgbe/COPYING","./usr/share/doc/kmod-ixgbe/README","./usr/share/doc/kmod-ixgbe/pci.updates","./usr/share/man/man7/ixgbe.7.gz","./usr/share/smartupdate/kmod-ixgbe/component.xml"],"Name":"kmod-ixgbe-6.3.4-1.rhel10u0.x86_64.rpm","SHA1Sum":"588ee1ffb3f8336c05ca63f3597fffbce1d01dee","SHA256Sum":"71bd1a565396e23ba3e3c54fbf08041febb5a6063f5503072688da5f9a84e4cd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3"],"TypeOfChange":"1","Version":"6.3.4-1"},{"Checksum":[{"Filename":"kmod-ixgbe-6.3.4-1.rhel10u1.x86_64.rpm","SHA1Sum":"2cc5c085406267b21aedd240d2377cb5d8ff76c2","SHA256Sum":"58a9b0391dbfc9bfb9eb054047f12ad660ed0d2828fd05c29abf531a8326f3f0","SHA512Sum":"24ccf277a8e61c894e4ecc5191c9fe06ec82c8445a7fdd4ca6cbcbe94539da88f2f2bd34e15c53961df4706f3cb680f1335bf069e78b93fcfdc07d98ee41a172"}],"ComponentSizeInKB":436,"CompsigList":["kmod-ixgbe-6.3.4-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbe.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ixgbe/ixgbe.ko","./usr/share/doc/kmod-ixgbe","./usr/share/doc/kmod-ixgbe/COPYING","./usr/share/doc/kmod-ixgbe/README","./usr/share/doc/kmod-ixgbe/pci.updates","./usr/share/man/man7/ixgbe.7.gz","./usr/share/smartupdate/kmod-ixgbe/component.xml"],"Name":"kmod-ixgbe-6.3.4-1.rhel10u1.x86_64.rpm","SHA1Sum":"2cc5c085406267b21aedd240d2377cb5d8ff76c2","SHA256Sum":"58a9b0391dbfc9bfb9eb054047f12ad660ed0d2828fd05c29abf531a8326f3f0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3"],"TypeOfChange":"1","Version":"6.3.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_661b77094d7a4165ba8b290b69","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U68","U68","U68","U71","U69","A58","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070912.zip","SHA1Sum":"cb0b1d96cb4ee6c104a5b7e84a6c29f579b08e2c","SHA256Sum":"09153868ed91b8f3b04dbc9deeace0c665f0b5c516196c237a1e4ee909644702","SHA512Sum":"a728feab8a91f2ab7105dc91b1b88ae1d7a9878bf67a981447cc3c3f98643b43f6079bc289900812c2953129be66c932f1e097028e948d2a4e7cba78b22690de"}],"ComponentSizeInKB":18029,"CompsigList":["CP070912.compsig"],"FileList":["/CP070912_BUILD_3.data","/CP070912.vmexe64","/CP070912.vmfile","/CP070912_VMw.zip","/CP070912.xml","/payload.json","/CP070912_VMw.zip/index.xml","/CP070912_VMw.zip/vendor-index.xml","/CP070912_VMw.zip/metadata.zip","/CP070912_VMw.zip/vib20/CP070912/HPE_bootbank_CP070912_HPD5.3-8.0.0.20613240.vib","/CP070912_VMw.zip/metadata.zip/vendor-index.xml","/CP070912_VMw.zip/metadata.zip/vmware.xml","/CP070912_VMw.zip/metadata.zip/vibs/CP070912-115404499603795932.xml","/CP070912_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070912_HPD5.3-8.0.0.20613240.xml"],"Name":"CP070912.zip","SHA1Sum":"cb0b1d96cb4ee6c104a5b7e84a6c29f579b08e2c","SHA256Sum":"09153868ed91b8f3b04dbc9deeace0c665f0b5c516196c237a1e4ee909644702","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070912","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6a872aeea25942bb845dca350f","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.rpm","SHA1Sum":"949621b0c3452817b1706827c7a9739441c7fe97","SHA256Sum":"c89399ac69cb1d5ab7d4f32b9ea5c2b23fde7c48280f5144aecbd424b9074998","SHA512Sum":"631189040de65477929c4bf40ffc782b2a403d1d49c46f36375e5c444b35e7edbcb4766b1f728bddd631a1728eacf53e6ab949f69681a188ed9a747c9c32c887"}],"ComponentSizeInKB":5158,"CompsigList":["firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/CP072124.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/M52002TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072124.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072124.scexe"],"Name":"firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.rpm","SHA1Sum":"949621b0c3452817b1706827c7a9739441c7fe97","SHA256Sum":"c89399ac69cb1d5ab7d4f32b9ea5c2b23fde7c48280f5144aecbd424b9074998","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba6b193738c04fac9ce493b05d","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068889.zip","SHA1Sum":"79dc3f77064d27cabaa20e6d19bcc027d7d2f393","SHA256Sum":"10fa21f6f2712f729e18476ce0c73ce9b91496b2ad53a429d59c1f0c5ae87e94","SHA512Sum":"b1e9c95f0c2d0faaf74bcba8877a4694c6330c62205744122047f495fb11096f3f82dfef1edc33b5c63aaf8a3bb052090cb988916ab84b58fae7e7e80c81eb67"}],"ComponentSizeInKB":16647,"CompsigList":["cp068889.compsig"],"FileList":["/BCM-storcli_007.3604.0000.0000-03.zip","/BCM_bootbank_storcli_007.3604.0000.0000-03.vib","/cp068889.xml","/BCM-storcli_007.3604.0000.0000-03.zip/index.xml","/BCM-storcli_007.3604.0000.0000-03.zip/vendor-index.xml","/BCM-storcli_007.3604.0000.0000-03.zip/metadata.zip","/BCM-storcli_007.3604.0000.0000-03.zip/vib20/storcli/BCM_bootbank_storcli_007.3604.0000.0000-03.vib","/BCM-storcli_007.3604.0000.0000-03.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3604.0000.0000-03.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3604.0000.0000-03.zip/metadata.zip/vibs/storcli--1494967298003908797.xml","/BCM-storcli_007.3604.0000.0000-03.zip/metadata.zip/bulletins/BCM-storcli_007.3604.0000.0000-03.xml"],"Name":"cp068889.zip","SHA1Sum":"79dc3f77064d27cabaa20e6d19bcc027d7d2f393","SHA256Sum":"10fa21f6f2712f729e18476ce0c73ce9b91496b2ad53a429d59c1f0c5ae87e94","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"storcli","Version":"007.3604.0000.0000-03"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3604.0000.0000-03","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3604.0000.0000-03","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2933eb4cd94144adb521f0300c","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.rpm","SHA1Sum":"ee4c1c443e8f774233dfb3869921ad283096fac2","SHA256Sum":"2b4743100ebde6ee7f96ae2b8af842b6619f31ceb8be8994d998bf3a0bff2549","SHA512Sum":"034e2cc7656f2429680b45b8f69356053ee5ea20f1034bf66578c5b95137b7270687d875f12ce826e7bdb164e5345de19fad4f8870da4a05cb186d8303350915"}],"ComponentSizeInKB":5883,"CompsigList":["firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/CP070062.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/TAMG09scHPD6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070062.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070062.scexe"],"Name":"firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.rpm","SHA1Sum":"ee4c1c443e8f774233dfb3869921ad283096fac2","SHA256Sum":"2b4743100ebde6ee7f96ae2b8af842b6619f31ceb8be8994d998bf3a0bff2549","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90b9b789ed55414da53a2984ba","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"PICGen10-1.1.4-1.fwpkg","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","SHA512Sum":"3bf5c5d18dfebfe42234dd1a7ff9b091b3e55c7a36c9bbb6c960ae6523f7934a552ff3f09739d7fc5f2f99687671f7ca08fbac009b30ff45c26be56127e57c3b"}],"ComponentSizeInKB":147,"CompsigList":[],"FileList":["payload.json","PICGen10-1.1.4-1.xml","PICGen10_v1.1.4_hdr.signed.hex"],"Name":"PICGen10-1.1.4-1.fwpkg","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_84e80a3fb2e04c93b20e3b09f3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A43","A42","A43","A42","A42","A43","A41","A40","U34","U34","U46","U30","U46","U32","U31","U31","U36","U43","U60","U41","U33","U61","U44","U50","U39","U50","U56","U46","U65"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"CP071676.zip","SHA1Sum":"cfe8b0de1551bbb171c2040f7bbdb063155e35a1","SHA256Sum":"099d1071ba8c198326223f3e3b4df89fa4ff1a40f758b267545a5729a4fc79d2","SHA512Sum":"91dccb3a2968555028c5abd8d18aa0ee54faf32c070e87189ee28713ed1862f5ed5ee758687e72738377ff48724a3ce034676073deb11c5a05cdebbcd830c67a"}],"ComponentSizeInKB":23408,"CompsigList":["CP071676.compsig"],"FileList":["/CP071676.xml","/CP071676_VMw.zip","/payload.json","/CP071676.vmexe64","/CP071676.vmfile","/CP071676_VMw.zip/index.xml","/CP071676_VMw.zip/vendor-index.xml","/CP071676_VMw.zip/metadata.zip","/CP071676_VMw.zip/vib20/CP071676/HPE_bootbank_CP071676_1.0.2-1OEM.900.0.24755229.vib","/CP071676_VMw.zip/metadata.zip/vendor-index.xml","/CP071676_VMw.zip/metadata.zip/vmware.xml","/CP071676_VMw.zip/metadata.zip/vibs/CP071676-5176152155996728387.xml","/CP071676_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071676_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP071676.zip","SHA1Sum":"cfe8b0de1551bbb171c2040f7bbdb063155e35a1","SHA256Sum":"099d1071ba8c198326223f3e3b4df89fa4ff1a40f758b267545a5729a4fc79d2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.4","VibList":[{"Name":"CP071676","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.x","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36690d551a0948008188e18f3f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-iavf-4.13.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"01363b8692cac1d467c40cf84a7e7264f2ff382c","SHA256Sum":"c2bbc586e2dff69dc518101b9b315b313db5719c657d914bbca4818088d0af42","SHA512Sum":"6dc3ce528916f546ceead0b4ec2a695c8edbc5b55bc167b40487ee48b2ca2ff849a8a5e155002295ce4ee2a0135a9f80c69c78b8978ecca702afc0556cba391b"}],"ComponentSizeInKB":225,"CompsigList":["kmod-iavf-4.13.20-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-iavf.conf","./etc/modprobe.d/iavf.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/iavf/iavf.ko","./usr/share/doc/kmod-iavf","./usr/share/doc/kmod-iavf/COPYING","./usr/share/doc/kmod-iavf/README","./usr/share/doc/kmod-iavf/pci.updates","./usr/share/man/man7/iavf.7.gz","./usr/share/smartupdate/kmod-iavf/component.xml"],"Name":"kmod-iavf-4.13.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"01363b8692cac1d467c40cf84a7e7264f2ff382c","SHA256Sum":"c2bbc586e2dff69dc518101b9b315b313db5719c657d914bbca4818088d0af42","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec52bf8d0b"],"TypeOfChange":"1","Version":"4.13.20-1"},{"Checksum":[{"Filename":"kmod-iavf-4.13.20-1.rhel10u0.x86_64.rpm","SHA1Sum":"9837e70beba960134eaf39baa3c20a1615be46e9","SHA256Sum":"19f35831a3d8d9117630c3a145f18ca3f92835fbbfe27ef0825e464a82dbb97d","SHA512Sum":"d288bd358ee26c678c6737baa646f54aeec2bba605e2769ee9718c9d2586c6ce9b94ed401b882067f10959f08abdc5f56c289005c18d57652baf6502fa462332"}],"ComponentSizeInKB":226,"CompsigList":["kmod-iavf-4.13.20-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-iavf.conf","./etc/modprobe.d/iavf.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/iavf/iavf.ko","./usr/share/doc/kmod-iavf","./usr/share/doc/kmod-iavf/COPYING","./usr/share/doc/kmod-iavf/README","./usr/share/doc/kmod-iavf/pci.updates","./usr/share/man/man7/iavf.7.gz","./usr/share/smartupdate/kmod-iavf/component.xml"],"Name":"kmod-iavf-4.13.20-1.rhel10u0.x86_64.rpm","SHA1Sum":"9837e70beba960134eaf39baa3c20a1615be46e9","SHA256Sum":"19f35831a3d8d9117630c3a145f18ca3f92835fbbfe27ef0825e464a82dbb97d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec52bf8d0b"],"TypeOfChange":"1","Version":"4.13.20-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b11e8e7c1bdc476e8fdc7209fa","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070839.zip","SHA1Sum":"47c4de1d9de7d302bc1d5465809472134a2b4a27","SHA256Sum":"386244994d838c243376052a143d79a3d3b8a63a573f582e9b20edd68f049147","SHA512Sum":"938e662d13f4a214cd7d1ce630bcfac87be2fb15decfd8194fa3a1db3390d2eb362d8b1c4ca7e38c6de555261c9d665310532946473300676c15ca43a0e843c7"}],"ComponentSizeInKB":7017,"CompsigList":["cp070839.compsig"],"FileList":["/cp070839.xml","/amsdComponent_802.11.13.0.1-1.zip","/amsdComponent_802.11.13.0.1-1.zip/index.xml","/amsdComponent_802.11.13.0.1-1.zip/vendor-index.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip","/amsdComponent_802.11.13.0.1-1.zip/vib20/amsd/HPE_bootbank_amsd_802.11.13.0.1-1OEM.802.0.0.22380479.vib","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vendor-index.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vmware.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vibs/amsd--2353574801284761738.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/bulletins/amsdComponent_802.11.13.0.1-1.xml"],"Name":"cp070839.zip","SHA1Sum":"47c4de1d9de7d302bc1d5465809472134a2b4a27","SHA256Sum":"386244994d838c243376052a143d79a3d3b8a63a573f582e9b20edd68f049147","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"amsd","Version":"802.11.13.0.1-1OEM.802.0.0.22380479"}]}],"InstallationDependency":{},"Name":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":200,"RebootRequired":"yes","SWKeys":[{"Name":"amsdComponent:802.11.13.0.1-1","SWKeyExpectedPath":"software.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_498cb3dbd619486f92d80c88ed","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U41","U33","U37","U38","U38","I43","I42","U40","A41","U43","U44","A42","A43","U31","U31","U39","A46","U48","U46","U46","U50","U47","U47","I44","A42","A43","A43","A42","U61","U60","A48","A47","U45","U46","U56","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-18e328f036_0HPG8-2.1_amd64.deb","SHA1Sum":"859ea9b57bb26fbf7bd0c7612223110de0be7638","SHA256Sum":"6cc4322155f54d18d0aa885ce189ffc6b16170b5e337bb1cc3c71194304f208c","SHA512Sum":"3f4be5d4dab6901b3f84539083665c87f6c39ea992fe308ee003ca20559eb1e247344d14999909e2bca1bf92118d6e6b04ff8b6a4aac119e016c0d4e5d252f4c"}],"ComponentSizeInKB":4222,"CompsigList":["firmware-hdd-18e328f036_0HPG8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/CP071731.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071731.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071731.scexe"],"Name":"firmware-hdd-18e328f036_0HPG8-2.1_amd64.deb","SHA1Sum":"859ea9b57bb26fbf7bd0c7612223110de0be7638","SHA256Sum":"6cc4322155f54d18d0aa885ce189ffc6b16170b5e337bb1cc3c71194304f208c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_18bd953b7d614725834386e84b","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-059b8654a6_0HPG6-1.1_amd64.deb","SHA1Sum":"e2e901ef5f656ebed8d6b5f195a379da5d3303e8","SHA256Sum":"e69a0f627a19c5e0889543e1beeea11ddd2f71d2430bcb4a8f55bfbe2664a2fb","SHA512Sum":"1363ef35873616d239817b43d6872cc4b962eb596c9e9c4bd02899a433c750c48b111f40e565b883c7e107db2c763d65c09df834b6ceec6aa027623284e5e226"}],"ComponentSizeInKB":4568,"CompsigList":["firmware-hdd-059b8654a6_0HPG6-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/CP067368.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/WLHCWBA0HPG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067368.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067368.scexe"],"Name":"firmware-hdd-059b8654a6_0HPG6-1.1_amd64.deb","SHA1Sum":"e2e901ef5f656ebed8d6b5f195a379da5d3303e8","SHA256Sum":"e69a0f627a19c5e0889543e1beeea11ddd2f71d2430bcb4a8f55bfbe2664a2fb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"2","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f0b2c59f52c2492ab30bcaf711","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04","24.04","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB960HAJQ-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"},{"DeviceName":"MZ1LB1T9HALS-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"}]},"Files":[{"Checksum":[{"Filename":"cp070450.exe","SHA1Sum":"d696ce86946a31e2d11a9e3f37be97722fa67079","SHA256Sum":"132377578ac6296559d4826dd661535538a15e26120020311eb0a2c20e33c9ba","SHA512Sum":"99628d684a4344016e3ff51386ba19e8cf33ea991969106c6dbde88b1878bddbaa481c1ce3df3f57a20e6d0866e79f0eab27c3573a086d2a0bb7155ab7424ac2"}],"ComponentSizeInKB":7022,"CompsigList":["cp070450.compsig"],"FileList":["cp070450.xml","cpqsetup.exe","EDA7602Q.bin","ilorest_chif.dll","payload.json"],"Name":"cp070450.exe","SHA1Sum":"d696ce86946a31e2d11a9e3f37be97722fa67079","SHA256Sum":"132377578ac6296559d4826dd661535538a15e26120020311eb0a2c20e33c9ba","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDA7602Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MZ1LB960HAJQ-00007","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZ1LB1T9HALS-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bb509c565c0443b889276758c","SupportedDevices":["4d2340a5-315a-424c-3154-3948c2e5811f","4d2340a5-315a-424c-3936-304820becacc","4d2340a5-315a-424c-3354-384894df255d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.deb","SHA1Sum":"7d6873b3e5a6870916735e9d932d844adebbc20b","SHA256Sum":"36e516c917299af9ea44b5cec7adaeaae1e2818633b7784ebfef64f75f7d6939","SHA512Sum":"d374bdc47add5eb55f83f8b905da1b39eac725983378eb5f2d5da4a6ac43424eea948516a27152928350c8af9acdb636117ffbca66daa94de2bd1c22994a53ec"}],"ComponentSizeInKB":4452,"CompsigList":["firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/CP071755.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071755.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071755.scexe"],"Name":"firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.deb","SHA1Sum":"7d6873b3e5a6870916735e9d932d844adebbc20b","SHA256Sum":"36e516c917299af9ea44b5cec7adaeaae1e2818633b7784ebfef64f75f7d6939","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f0d865638f1452fbdb337a725","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u34-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"759f57a3acaa54f4301e76722cabd14e219ceeb8","SHA256Sum":"c2e19016ecd2bc4f97329f8aec8af3de74f12705271b3382f9009b94fbdcbde2","SHA512Sum":"f9e692cdec5c20140a709f95e72c3d99f32edc007fd3bcda62bd29eb1c2e67784e478e3d52d031c5bed81a081b1168bd5b80094d4d6ed266123eee6f5f2d3c95"}],"ComponentSizeInKB":11741,"CompsigList":["firmware-system-u34-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/CP071404.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/U34_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071404.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071404.scexe"],"Name":"firmware-system-u34-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"759f57a3acaa54f4301e76722cabd14e219ceeb8","SHA256Sum":"c2e19016ecd2bc4f97329f8aec8af3de74f12705271b3382f9009b94fbdcbde2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5cc8e735cb1b4dc7b311ed2199","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072292.exe","SHA1Sum":"339ef9d0b355a988ee5989ee7e34f0c0012b522f","SHA256Sum":"fa144e5d714b001782d7c080b17b944a84cdf59df03904c4909fa945df9f66b9","SHA512Sum":"eb548b2186c801513e96f3ce656ecf14b744632542cb5055ecfc287137c350e4ac1e3288d202f34603dcebc532783166b4c6821bdb95958d6ce86ee824b33c01"}],"ComponentSizeInKB":567,"CompsigList":["cp072292.compsig"],"FileList":["cp072292.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp072292.exe","SHA1Sum":"339ef9d0b355a988ee5989ee7e34f0c0012b522f","SHA256Sum":"fa144e5d714b001782d7c080b17b944a84cdf59df03904c4909fa945df9f66b9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4ce3ef0c8916442f8dca8bbc3f","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U36","U43","U41","U33","U44","A47","U40","U39","U45","U37","A46","U38","U38","U48","I43","I42","I44","U46","U46","U47","U47","U50","U61","U60","U56","A43","A42","A43","A42","A48","U50","U40","U39","U64","H10","H10","H10","H08","H08"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","SHA1Sum":"f47c954b8b2fb2d1182df2756cfd01fd6d737749","SHA256Sum":"f8867e559a63ee939b9634c764c4402fd9a63827694c92e48b90965f9707279f","SHA512Sum":"c325adf0188cfa19b068f8e5bf8c0cb9be17cb2123c937602a1f58f4e3cf33d00a37182371a82b64b4e1536f36c8536c2daecda9f5a3b73571db4d28454b35e1"}],"ComponentSizeInKB":5394,"CompsigList":["firmware-hdd-ef93133161-HPD4-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/CP068854.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068854.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068854.scexe"],"Name":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","SHA1Sum":"f47c954b8b2fb2d1182df2756cfd01fd6d737749","SHA256Sum":"f8867e559a63ee939b9634c764c4402fd9a63827694c92e48b90965f9707279f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_728eef229104453693c5a71e67","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9475583fb5_0HPG1-2.1_amd64.deb","SHA1Sum":"0ba5d30da9df71e711e47b6ae51e152da7b5fbcd","SHA256Sum":"9cacf3d8a9e61810fc11b6dbae57781b5f6f7dcd93638ff79ae39cde396dccf4","SHA512Sum":"0d253d1a3d6301d3decabb5cc675e00f9f25623c908f12e6613d6820ad6973145e6ae14058627231e172143e4a929528fb3d74ca0fa08a68da73260024952dfc"}],"ComponentSizeInKB":4137,"CompsigList":["firmware-hdd-9475583fb5_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/CP071803.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/HPG1PM897.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071803.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071803.scexe"],"Name":"firmware-hdd-9475583fb5_0HPG1-2.1_amd64.deb","SHA1Sum":"0ba5d30da9df71e711e47b6ae51e152da7b5fbcd","SHA256Sum":"9cacf3d8a9e61810fc11b6dbae57781b5f6f7dcd93638ff79ae39cde396dccf4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58f15fdfecdf4addbbdd5ca7ed","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072097.exe","SHA1Sum":"8457d5973764d5a4edda877c75efc313e256e69c","SHA256Sum":"bacce6928643839f47035a252ebc1434565bd00be09aec579a447d092f765036","SHA512Sum":"5d929462aa9145f838f49d506af87f61273d5018e3ed61099db241efe18179385cc7baaedbe375f868f1bb4fd4c837a4483ab3cc24c2a61886514801d75e31ac"}],"ComponentSizeInKB":3491,"CompsigList":["cp072097.compsig"],"FileList":["cp072097.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSADU66590_X64.msi"],"Name":"cp072097.exe","SHA1Sum":"8457d5973764d5a4edda877c75efc313e256e69c","SHA256Sum":"bacce6928643839f47035a252ebc1434565bd00be09aec579a447d092f765036","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67b2f9aee63c4fadb663be4789","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","A42","U46","I44","U63","I45","U58","U59","U54","U54","U54","U63","U58","U58","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U65","U62","U71","U71","U68","U68","U72","A66","A66","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Files":[{"Checksum":[{"Filename":"cp070383.exe","SHA1Sum":"e2fcbfeb56241899a7330bcb8ed4511a18f3c3e8","SHA256Sum":"fdf19b3027d88f840dfd5d9db30a427869cbc289e135d263f985966b819f1e3d","SHA512Sum":"97d3c19629af027d7114e1cc843013ea715cbb96f572fe9e79375876ef351afdfc47f73410945a467990669663a368db47939009d77b093060aac9917a5b7099"}],"ComponentSizeInKB":10750,"CompsigList":["cp070383.compsig"],"FileList":["BootIMG.FLB","cp070383.xml","cpqsetup.exe","ilorest_chif.dll","Immediate_offset_1.txt","Immediate_offset_2.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","nvmupdatew64e.exe","OCP_Configuration.txt","payload.json","payload_version.txt","QSFP.cfg","RJ45.cfg","SFP.cfg","version.txt"],"Name":"cp070383.exe","SHA1Sum":"e2fcbfeb56241899a7330bcb8ed4511a18f3c3e8","SHA256Sum":"fdf19b3027d88f840dfd5d9db30a427869cbc289e135d263f985966b819f1e3d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"InstallationDependency":{},"Name":"HPE Edgeline X722 NIC Firmware Component for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66b90de597c94dbfaf7482bc51","SupportedDevices":["a6b1a447-382a-5a4f-8086-37D380860000","a6b1a447-382a-5a4f-8086-37D180860000","a6b1a447-382a-5a4f-8086-37CE80860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-megaraid_sas-07.736.04.00_rhel9u6-1.x86_64.rpm","SHA1Sum":"7fe57b00d65f849f95f0cf2bb81c4b5eefd7c7c5","SHA256Sum":"d0f7ca2c25e86bbc1d45d4d6d91724e784a5eb2a8ee4fa586821e3204b2b304d","SHA512Sum":"023d79843aacea69a401e366774fbf5f078909bbb712f3b5c8846880210743cfcfd67e03463a16579e5584c087a0123e6d878e1d6a9f39e26642fc42dd32af3d"}],"ComponentSizeInKB":122,"CompsigList":["kmod-megaraid_sas-07.736.04.00_rhel9u6-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.736.04.00_rhel9u6-1.x86_64.rpm","SHA1Sum":"7fe57b00d65f849f95f0cf2bb81c4b5eefd7c7c5","SHA256Sum":"d0f7ca2c25e86bbc1d45d4d6d91724e784a5eb2a8ee4fa586821e3204b2b304d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.736.04.00"},{"Checksum":[{"Filename":"kmod-megaraid_sas-07.736.04.00_rhel9u7-1.x86_64.rpm","SHA1Sum":"90530f2437fe683986a01090f76eefa3b00b0473","SHA256Sum":"3a2ca664f529c6572167ecf5a1d5e572fc95d3d2db4f5c055a3f46701bc59caf","SHA512Sum":"ee0c2c1fa0a9113988c557518c13464f8e432c4e3da83c666424afd33a76d5d000224d9d0a12e0953d778fd9d9fabf186b53d31a726ba3e151a8a7ee041f38ea"}],"ComponentSizeInKB":136,"CompsigList":["kmod-megaraid_sas-07.736.04.00_rhel9u7-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.736.04.00_rhel9u7-1.x86_64.rpm","SHA1Sum":"90530f2437fe683986a01090f76eefa3b00b0473","SHA256Sum":"3a2ca664f529c6572167ecf5a1d5e572fc95d3d2db4f5c055a3f46701bc59caf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.736.04.00"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35defd3e087b41669dcdb71f86","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U46","U30","U32","U61","A42","A43","A43","A42","U60","U63","U59","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.deb","SHA1Sum":"1af762ee6f3356a20c05fddb4140c3242e6b32bb","SHA256Sum":"c93452f08753d156ce25ec9efafab571a1e158490a6be4133f0741a978d37c89","SHA512Sum":"7b9598af03ed7926305c74b5e1ddd21bba8b9ad98ae72fe066c50c5728a571be8a2497e2279d21ee84c305c1db516aa84f1a683c46313341f3788f6859dadfb7"}],"ComponentSizeInKB":5031,"CompsigList":["firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/CP071773.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071773.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071773.scexe"],"Name":"firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.deb","SHA1Sum":"1af762ee6f3356a20c05fddb4140c3242e6b32bb","SHA256Sum":"c93452f08753d156ce25ec9efafab571a1e158490a6be4133f0741a978d37c89","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b60d101ae594e83a0300f19a7","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"cp067916.exe","SHA1Sum":"ab45da455fc8605979d9faef8470b42d9b6f2246","SHA256Sum":"5bd3d79c3cf13c93a02403ea31857860080def96250cf967ba9e04b9050e8471","SHA512Sum":"be688a324edd9c335ef4f75fc80521c0a46e5474c9247e7b2183393e1764d48e16018b7e760f82539f53658e5aa48c98e99787b4a6873780f06772a1c02a2f21"}],"ComponentSizeInKB":3542,"CompsigList":["cp067916.compsig"],"FileList":["cp067916.xml","cpqsetup.exe","firmware-Signed-5.15-build-000.bin.fw","payload.json","setup.dll"],"Name":"cp067916.exe","SHA1Sum":"ab45da455fc8605979d9faef8470b42d9b6f2246","SHA256Sum":"5bd3d79c3cf13c93a02403ea31857860080def96250cf967ba9e04b9050e8471","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ec7574dfdf54b5b857e9c488e","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068763.exe","SHA1Sum":"8229f5d9249c1a4d76bff4a581aaea9da46adfbe","SHA256Sum":"d7d3fadc15fc0935e9011d00b8f2e856d78226775edb127e57509f78bf3b84d9","SHA512Sum":"aa88ec4d4ead30cfacc3e6c9faf958f6eae717881e7867ded078842d219d20737d1d4e90946b48f532da75dfd93d8f23fbb78693e6ec74f0c572bdacf58ace76"}],"ComponentSizeInKB":3179,"CompsigList":["cp068763.compsig"],"FileList":["cp068763.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEN0HPD6.rel"],"Name":"cp068763.exe","SHA1Sum":"8229f5d9249c1a4d76bff4a581aaea9da46adfbe","SHA256Sum":"d7d3fadc15fc0935e9011d00b8f2e856d78226775edb127e57509f78bf3b84d9","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e186208a59f74883a23b4da1fb","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.deb","SHA1Sum":"09e388af557cc23397f53a5ccc515c929c008b2b","SHA256Sum":"c3cd8762d60b06e00dc3a21160e35c01501febf4908dd57d7c5dbf2d38feb7a2","SHA512Sum":"df3068436d427846c111b84113ab75cc377a4e68effc969ff76a391cb210e49c4b2464bc95aa93d75f0f9445a95d51eb4ac30a88bfdfa1983daa8ff0920b71db"}],"ComponentSizeInKB":4472,"CompsigList":["firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/CP071781.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071781.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071781.scexe"],"Name":"firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.deb","SHA1Sum":"09e388af557cc23397f53a5ccc515c929c008b2b","SHA256Sum":"c3cd8762d60b06e00dc3a21160e35c01501febf4908dd57d7c5dbf2d38feb7a2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e4343e7341204d8faedd7a7588","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070547.exe","SHA1Sum":"db353b9cb8e28a8bad2f348a8f2ba2fb762db54b","SHA256Sum":"5fb2bb7c90e83208224bc1ae69edcf950f2fa4ddcf3280431f04850a9246ffc7","SHA512Sum":"541a73572506b1b2ff1cb5d1aacb6a592df89c4cbb82469604eb0b135a10b90e2ee271008968347d7f36c8eca359a03eefffffe4a899f6a645f07ef541f99ba7"}],"ComponentSizeInKB":1512,"CompsigList":["cp070547.compsig"],"FileList":["cp070547.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070547.exe","SHA1Sum":"db353b9cb8e28a8bad2f348a8f2ba2fb762db54b","SHA256Sum":"5fb2bb7c90e83208224bc1ae69edcf950f2fa4ddcf3280431f04850a9246ffc7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.24.41.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dfb9ace971df4816b72d0ebcf7","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072194.exe","SHA1Sum":"bdec293e21f03241085289c2782131ff9f908c16","SHA256Sum":"0e51ebcd369d2e1a1330fca8f7af721585a3622634826f7c94466fd361efa99f","SHA512Sum":"a68cfc09871c47f0438be68d80571f873442dc7d7f4f58db17cb3a48569c9463b65ef7d5a7695e504bdb4a7e6c1f57d0854e2d306cf980d1d5f30054289c3859"}],"ComponentSizeInKB":2432,"CompsigList":["cp072194.compsig"],"FileList":["cp072194.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072194.exe","SHA1Sum":"bdec293e21f03241085289c2782131ff9f908c16","SHA256Sum":"0e51ebcd369d2e1a1330fca8f7af721585a3622634826f7c94466fd361efa99f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cae1e2a7f96f4f1ab1031483d8","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101e15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.rpm","SHA1Sum":"23c65578412b38c463e951b9a77f9990a19a32a3","SHA256Sum":"2e6b2b1c44030b3beecb17c70e4bceeb93ff6b41ad0aa49493ab31172b3cbe15","SHA512Sum":"b9022534067369814e4415cf62edf25fa0760b1924ce9114ba4c8641ce496d7733ffd73cc2de43c2871cfc744b030d477c0369272a3396868e22582a0e03c262"}],"ComponentSizeInKB":112,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.rpm","SHA1Sum":"23c65578412b38c463e951b9a77f9990a19a32a3","SHA256Sum":"2e6b2b1c44030b3beecb17c70e4bceeb93ff6b41ad0aa49493ab31172b3cbe15","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 16 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a719c2d70eb4fc585c6c7f552","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","U46","U46","A43","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"cp071598.exe","SHA1Sum":"6ccdeb9e381456be20692147dbb90bc656bf3b2e","SHA256Sum":"617925090304a6319a3b772ac183ce855b7bc87f603ac33653823657fb998e41","SHA512Sum":"7950e215b4f4548056d2d6e65e46ad6c681a0d14aa042ac056cf787784791ba1791a437f2c8c30c3f1aa2cd994f954e0d7f77e585003c106f1ef8a939582a818"}],"ComponentSizeInKB":7366,"CompsigList":["cp071598.compsig"],"FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp071598.xml","cpqsetup.exe","FW/","FW/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","FW/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","FW/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","FW/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp071598.exe","SHA1Sum":"6ccdeb9e381456be20692147dbb90bc656bf3b2e","SHA256Sum":"617925090304a6319a3b772ac183ce855b7bc87f603ac33653823657fb998e41","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"5.4.7.0"}],"InstallationDependency":{},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2f924791af1149339734758af0","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U47","U46","A42","A42","A43","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U68","U72","U70","A66","A66","U77","03030202","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.deb","SHA1Sum":"8b29852e27e19667777c8df9f76e6219706cb87f","SHA256Sum":"ee836d4d9f421e91dc35a91b15629147f029473f3c84b4c2f03c33e0c14763d8","SHA512Sum":"53906b7d3ccf6b459907047f56f7fcde8e899f70671dc8801cd9cb9fa823273b9ecbfcccb68053b284ffab417c79788844bcf49cf9fe3609bde87a55bfca5553"}],"ComponentSizeInKB":3654,"CompsigList":["firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/CP071750.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071750.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071750.scexe"],"Name":"firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.deb","SHA1Sum":"8b29852e27e19667777c8df9f76e6219706cb87f","SHA256Sum":"ee836d4d9f421e91dc35a91b15629147f029473f3c84b4c2f03c33e0c14763d8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03da487f589342e099df1431ab","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ice-2.4.5-1.rhel10u0.x86_64.rpm","SHA1Sum":"f6c2fd02cc3a0f6788ab0b8c72cf069bc889bc05","SHA256Sum":"236568a4dfa7fa3c5657b8a62f59aeeb5b2c38b35d3a3292a6a6e8dd4be49765","SHA512Sum":"b4fc61682a84189b2dd14231ffbdf25d123374ebbee9bb525f07a6a9028a48529ffd07a7e8f228f28c4507fec3d747295d4be8c549891be25530909f81cf88b3"}],"ComponentSizeInKB":1158,"CompsigList":["kmod-ice-2.4.5-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ice.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/ice/ice.ko","./usr/share/doc/kmod-ice","./usr/share/doc/kmod-ice/COPYING","./usr/share/doc/kmod-ice/README","./usr/share/doc/kmod-ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.4.5-1.rhel10u0.x86_64.rpm","SHA1Sum":"f6c2fd02cc3a0f6788ab0b8c72cf069bc889bc05","SHA256Sum":"236568a4dfa7fa3c5657b8a62f59aeeb5b2c38b35d3a3292a6a6e8dd4be49765","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.4.5-1"},{"Checksum":[{"Filename":"kmod-ice-2.4.5-1.rhel10u1.x86_64.rpm","SHA1Sum":"58dd34acbf7e8f1fc12246225df33f3f5885ad9e","SHA256Sum":"cf5f54ea8511a57b8fd282174c08910ec8c74248988f107bf38245ed36339abe","SHA512Sum":"b1b1926db78535f6f3b40a4a79886d3d3cba7a46588c06c2d61e9d274a8fb87fa2120b541466ae6178348f2420329381f136149b0b763444ed55734fc249c12a"}],"ComponentSizeInKB":1159,"CompsigList":["kmod-ice-2.4.5-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ice.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ice/ice.ko","./usr/share/doc/kmod-ice","./usr/share/doc/kmod-ice/COPYING","./usr/share/doc/kmod-ice/README","./usr/share/doc/kmod-ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.4.5-1.rhel10u1.x86_64.rpm","SHA1Sum":"58dd34acbf7e8f1fc12246225df33f3f5885ad9e","SHA256Sum":"cf5f54ea8511a57b8fd282174c08910ec8c74248988f107bf38245ed36339abe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.4.5-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ff7da5a2cb8b41e789d6e9d931","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a886842a99-HPD2-10.1.x86_64.rpm","SHA1Sum":"e266dfe0f7fe8f28c25695965efa3e594d7368a3","SHA256Sum":"c51eb3037ffeeed4b6d3e8ce1962dc8054eeb7eb524bcfa82a46ab047df0ece0","SHA512Sum":"5e96b7c43af83a556e52bad04032e741316aa320fa4952c8e84f850a59b4b752904425957f06a03ae0b31f09cffd3bd34f986089f6e0451bebd1ab32e61913c4"}],"ComponentSizeInKB":6266,"CompsigList":["firmware-hdd-a886842a99-HPD2-10.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/CP068842.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068842.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068842.scexe"],"Name":"firmware-hdd-a886842a99-HPD2-10.1.x86_64.rpm","SHA1Sum":"e266dfe0f7fe8f28c25695965efa3e594d7368a3","SHA256Sum":"c51eb3037ffeeed4b6d3e8ce1962dc8054eeb7eb524bcfa82a46ab047df0ece0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c2b3957b6e54829a9ca2b3d68","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"CP070917.zip","SHA1Sum":"425044d472e0b453cc19bd21350a293b2ca10ec9","SHA256Sum":"ee1fa0c53a8224247e37f8c5802fbe9c89345305181e015ab24eea1e65862e36","SHA512Sum":"392000d924b9e8e66fa53d075bc16dbd404a118b897d6e48b04892411a5b6ad0f1a8423efed8e98d3308386a20e1ca2fb6b61b0868b0c9bfa485c604b5e11b3c"}],"ComponentSizeInKB":26905,"CompsigList":["CP070917.compsig"],"FileList":["/CP070917_BUILD_3.data","/CP070917.vmexe64","/CP070917.vmfile","/CP070917_VMw.zip","/CP070917.xml","/payload.json","/CP070917_VMw.zip/index.xml","/CP070917_VMw.zip/vendor-index.xml","/CP070917_VMw.zip/metadata.zip","/CP070917_VMw.zip/vib20/CP070917/HPE_bootbank_CP070917_MPK7825Q.3-8.0.0.20613240.vib","/CP070917_VMw.zip/metadata.zip/vendor-index.xml","/CP070917_VMw.zip/metadata.zip/vmware.xml","/CP070917_VMw.zip/metadata.zip/vibs/CP070917-7693931915171505373.xml","/CP070917_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070917_MPK7825Q.3-8.0.0.20613240.xml"],"Name":"CP070917.zip","SHA1Sum":"425044d472e0b453cc19bd21350a293b2ca10ec9","SHA256Sum":"ee1fa0c53a8224247e37f8c5802fbe9c89345305181e015ab24eea1e65862e36","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q","VibList":[{"Name":"CP070917","Version":"MPK7825Q.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bf93a6c84c08409e91b268b1c8","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a27c95663d_0HPK6-2.1_amd64.deb","SHA1Sum":"e873e4959db56ee481b773981471f172e79213ca","SHA256Sum":"8cc9d49395be9eb28151ee3346d04a1a76e8ee5ad87f926b6b8e253d550e8e6d","SHA512Sum":"a4dc38960982702c4f65aecf1904c52ff0b232a669dfdbdc0c913b2ae91100e56274b9df0b5f3e3ec6e8ac7fdd9c334ed2022699206b1ee122eb9fff514e6976"}],"ComponentSizeInKB":5649,"CompsigList":["firmware-hdd-a27c95663d_0HPK6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/CP071813.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071813.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071813.scexe"],"Name":"firmware-hdd-a27c95663d_0HPK6-2.1_amd64.deb","SHA1Sum":"e873e4959db56ee481b773981471f172e79213ca","SHA256Sum":"8cc9d49395be9eb28151ee3346d04a1a76e8ee5ad87f926b6b8e253d550e8e6d","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3bc62e2d2bcd411692af30d380","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Operating System - Enhancements","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069670.exe","SHA1Sum":"1850c83f4a988cc95ff1168f24af16043035efa8","SHA256Sum":"00289058e393cff1285e7033f8ce278d50b2159af05be72e4f542de5455aa620","SHA512Sum":"e8363039b653485b97b7b233cef7c3f68dba83c9d82394439c45bc915bf01be5666cdd6617ea820fc7f13cb30e8dd023f738d295dbe9c8a65e71abcb0c9c0f9e"}],"ComponentSizeInKB":616,"CompsigList":["cp069670.compsig"],"FileList":["cp069670.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"Name":"cp069670.exe","SHA1Sum":"1850c83f4a988cc95ff1168f24af16043035efa8","SHA256Sum":"00289058e393cff1285e7033f8ce278d50b2159af05be72e4f542de5455aa620","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"InstallationDependency":{},"Name":"AMD PSHED Plug-in service for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9001e38f8173493b9fb7ad5c3a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["A55","A56","A55","A56","A42","A42","A40","A42","A43","A43","A43","A41","A47","A48","A46","HPE Cray XD295v"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070970.zip","SHA1Sum":"98ea4de88abc770395a0a1cdc993f648542a436c","SHA256Sum":"f6ae740f7d9c6f5859ec8f37d11a0c807f5786568e99253782bbbc0d931144cd","SHA512Sum":"9c351c48ae1e3e015b0e1a5dc9e03d73f8ca02577da7b54e12479b8f49c6b0b3968276bd38bc7bd4e28e4b8cb016e7b509dc1b7e469ede57a4dd52c196f85402"}],"ComponentSizeInKB":20163,"CompsigList":["CP070970.compsig"],"FileList":["/CP070970_BUILD_1.data","/CP070970.vmexe64","/CP070970.vmfile","/CP070970_VMw.zip","/CP070970.xml","/payload.json","/CP070970_VMw.zip/index.xml","/CP070970_VMw.zip/vendor-index.xml","/CP070970_VMw.zip/metadata.zip","/CP070970_VMw.zip/vib20/CP070970/HPE_bootbank_CP070970_HPD2.1-8.0.0.20613240.vib","/CP070970_VMw.zip/metadata.zip/vendor-index.xml","/CP070970_VMw.zip/metadata.zip/vmware.xml","/CP070970_VMw.zip/metadata.zip/vibs/CP070970-2875428224483635812.xml","/CP070970_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070970_HPD2.1-8.0.0.20613240.xml"],"Name":"CP070970.zip","SHA1Sum":"98ea4de88abc770395a0a1cdc993f648542a436c","SHA256Sum":"f6ae740f7d9c6f5859ec8f37d11a0c807f5786568e99253782bbbc0d931144cd","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070970","Version":"HPD2.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c45b8a31e9084c7c866294b659","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070483.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.925"}]},"Files":[{"Checksum":[{"Filename":"firmware-spsgen10plus-04.04.04.925-1.1.x86_64.rpm","SHA1Sum":"4bded1e8e8877bb675a75d12f9f0548f24ba0b41","SHA256Sum":"6e6a1a7d1ac825a1eb9fb5bd696c14d083faaf0f909fe27834d2dceca0c5135d","SHA512Sum":"b8f264c8d06ef5b9be7767d8f170e46ae2d38351183dd718f618f88034c87373a3037f96b31356febaaeff9da79d07f73874a5de0a6fa78797f029828677a48b"}],"ComponentSizeInKB":8382,"CompsigList":["firmware-spsgen10plus-04.04.04.925-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/CP070485.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/cp070483.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/cp070483.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.925-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070485.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070485.scexe"],"Name":"firmware-spsgen10plus-04.04.04.925-1.1.x86_64.rpm","SHA1Sum":"4bded1e8e8877bb675a75d12f9f0548f24ba0b41","SHA256Sum":"6e6a1a7d1ac825a1eb9fb5bd696c14d083faaf0f909fe27834d2dceca0c5135d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.925"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5981938904754cbfa813d86a86","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"cp071592.exe","SHA1Sum":"d954e2c9adb941ae639071b3498ba68b051b9cf6","SHA256Sum":"cdc7a392409add2749733da5e935a5852b9048ae0f47e436ddbd26dfde0cc419","SHA512Sum":"61a1be35f909df032efd0b3942839c104d67816a133883051754a49c3ed422808233bcb2543fc4b98f6f1739ea2a71aaa6c75474a203f49a2c8e8a2ad808daaf"}],"ComponentSizeInKB":8250,"CompsigList":["cp071592.compsig"],"FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp071592.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp071592.exe","SHA1Sum":"d954e2c9adb941ae639071b3498ba68b051b9cf6","SHA256Sum":"cdc7a392409add2749733da5e935a5852b9048ae0f47e436ddbd26dfde0cc419","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"5.4.7.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Windows Server x64 Editions for HPE ProLiant Gen10 server series Only","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a90f1fb24ad14362830fc89cda","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U39_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071435.exe","SHA1Sum":"033fdbe8818acf98bb7430470e0a120d1a0792c7","SHA256Sum":"0eff4b3f92fbc4b138805a5767037e85f2d47c1d9b94ac1094038bebdd1d123d","SHA512Sum":"741255f28fef380f15d6be0f4da8ca020ebe95fd7b914a853b8b9b126970d2aa903c4cfbb43ab40c4d0af95890548d0ce114dd2764f7b895814edc915df92733"}],"ComponentSizeInKB":11548,"CompsigList":["cp071435.compsig"],"FileList":["cp071435.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_3.66_04_01_2026.signed.flash"],"Name":"cp071435.exe","SHA1Sum":"033fdbe8818acf98bb7430470e0a120d1a0792c7","SHA256Sum":"0eff4b3f92fbc4b138805a5767037e85f2d47c1d9b94ac1094038bebdd1d123d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_100b042f7fd546e5b9fb89dc64","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d550523365_0HPD3-2.1_amd64.deb","SHA1Sum":"ea159c0d587f8c5ba971d28106ce41d0b60096d8","SHA256Sum":"a0b052783a83ea9922bdbf22b0b9b5fada9b1372f7d664f50266d1db735c2d5a","SHA512Sum":"1b00d94fd9bfc611dfad3d75475899030aa52ab3e12c16eba1d5153439fd3dd89df98497e894c1c4a0945b834a180877c83919b4b0ce5d0c9c0a110fce0427ce"}],"ComponentSizeInKB":5242,"CompsigList":["firmware-hdd-d550523365_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/CP071793.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/PCHFA2B3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071793.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071793.scexe"],"Name":"firmware-hdd-d550523365_0HPD3-2.1_amd64.deb","SHA1Sum":"ea159c0d587f8c5ba971d28106ce41d0b60096d8","SHA256Sum":"a0b052783a83ea9922bdbf22b0b9b5fada9b1372f7d664f50266d1db735c2d5a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f6b90f2e07d2491d85b2fc54b1","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070564.exe","SHA1Sum":"aba37f95e1f259eb9542f52ac48dceb775e80334","SHA256Sum":"8d884eb1247c570caf5cddb283bbb0c5e87ac0e8340f29d16f63d3bf50b39d3d","SHA512Sum":"3ffbdd36cd06859a51c2791ed8582cd14e68b051d65d59f0bb7f557f384ae6f53fac6c0d335375404d7ddf566d48909e0333eba9c409d400162cdc8d284ff2b5"}],"ComponentSizeInKB":1386,"CompsigList":["cp070564.compsig"],"FileList":["cp070564.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp070564.exe","SHA1Sum":"aba37f95e1f259eb9542f52ac48dceb775e80334","SHA256Sum":"8d884eb1247c570caf5cddb283bbb0c5e87ac0e8340f29d16f63d3bf50b39d3d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.18.158.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27e0af300e254765a9b481eb03","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"CP071591.zip","SHA1Sum":"3fabf6d5d2d66a8dcee0fcb55a6c64b4e3399f7f","SHA256Sum":"419cded577556733bd8d99e214e8a8e23813d71b56d774eb5c0297f1e4cdd63b","SHA512Sum":"ee0ec349261b8cdbd1e244b5d39f62ffcdf4254de7beea97416a0c514e167e52a3038ca474a8bdae20e07fbc6ac3a97f9bcd1cdea744562e5a96c609156690d4"}],"ComponentSizeInKB":18134,"CompsigList":["CP071591.compsig"],"FileList":["/CP071591_BUILD_1.data","/CP071591.vmexe64","/CP071591.vmfile","/CP071591_VMw.zip","/CP071591.xml","/payload.json","/CP071591_VMw.zip/index.xml","/CP071591_VMw.zip/vendor-index.xml","/CP071591_VMw.zip/metadata.zip","/CP071591_VMw.zip/vib20/CP071591/HPE_bootbank_CP071591_1.44.0.1-8.0.0.20613240.vib","/CP071591_VMw.zip/metadata.zip/vendor-index.xml","/CP071591_VMw.zip/metadata.zip/vmware.xml","/CP071591_VMw.zip/metadata.zip/vibs/CP071591--8110728031299593105.xml","/CP071591_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071591_1.44.0.1-8.0.0.20613240.xml"],"Name":"CP071591.zip","SHA1Sum":"3fabf6d5d2d66a8dcee0fcb55a6c64b4e3399f7f","SHA256Sum":"419cded577556733bd8d99e214e8a8e23813d71b56d774eb5c0297f1e4cdd63b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"1.44.0","VibList":[{"Name":"CP071591","Version":"1.44.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_525d8c27bff547428e9a07d69c","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200/EN 200G 1p OSFP Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","InstallDurationSec":900,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30085","Version":"28.49.1014"}]},"Files":[{"Checksum":[{"Filename":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","SHA1Sum":"42d62ce023470bd177169a833920a6dad9d62f5a","SHA256Sum":"532147711a3796789474b755ca7b7b43cedd1108666f24cef27684ef74cbf317","SHA512Sum":"7e7acb9c9dfbd7155294a71ed97e9fd1afae3fcd0d179ae1f8401d0ebc12da35568e9805384c75593b5c81360f2140da8ecfceb7fe57a997edc05b4ece47001d"}],"ComponentSizeInKB":9397,"CompsigList":[],"FileList":["28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.xml","payload.json"],"Name":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","SHA1Sum":"42d62ce023470bd177169a833920a6dad9d62f5a","SHA256Sum":"532147711a3796789474b755ca7b7b43cedd1108666f24cef27684ef74cbf317","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30085"],"TypeOfChange":"1","Version":"28.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":900,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT_VPI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13c7d34506c44a52be6fdd355e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30085"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["9.0","8.0","7.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58","U72","U70","A59","U66","U71","U71","U68","U68","U68","A66","A66","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071512.exe","SHA1Sum":"489c9bf911bd59453436400eae81d70a47b35975","SHA256Sum":"c63a149ec04301c4b163ee5affe523684a93f72391aaa38ee7a3797ba1f75dcd","SHA512Sum":"62b818e1cb6106cb59aeca4aee39724d2d1602fe39a5163e99c007b58a6fb27f767fa9d05947bc9386c6c1cfb7bc11aa67fa70e2738430635c6967a05f2655a4"}],"ComponentSizeInKB":33436,"CompsigList":["cp071512_part1.compsig","cp071512_part2.compsig"],"FileList":["A46_4.04_04_02_2026.signed.flash","cp071512.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071512.exe","SHA1Sum":"489c9bf911bd59453436400eae81d70a47b35975","SHA256Sum":"c63a149ec04301c4b163ee5affe523684a93f72391aaa38ee7a3797ba1f75dcd","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f2c02701d3864e43b8528557eb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p56_CFGID7p2_K97342_800100D3.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3909.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p56_CFGID7p2_K97470_800100DE.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"}]},"Files":[{"Checksum":[{"Filename":"CP070391.zip","SHA1Sum":"c4affbd29724756b769155a25662a7aa4dc1cbb6","SHA256Sum":"b7047b0954994fadf48c67e5625d2db9ca3e3fb828fd3a74a2af481bf3d72f71","SHA512Sum":"aea0eaebe1e39201c4304d2f8ea232f72b2642a466f94722195da83257976316aeb41d02dbc48e5b69cb3564e714c9136478b69f93f43588e0537578d895f073"}],"ComponentSizeInKB":7835,"CompsigList":["CP070391.compsig"],"FileList":["/CP070391_BUILD_3.data","/CP070391_VMw.zip","/CP070391.xml","/payload.json","/CP070391_VMw.zip/index.xml","/CP070391_VMw.zip/vendor-index.xml","/CP070391_VMw.zip/metadata.zip","/CP070391_VMw.zip/vib20/CP070391/HPE_bootbank_CP070391_3.29.0.3-8.0.0.20613240.vib","/CP070391_VMw.zip/metadata.zip/vendor-index.xml","/CP070391_VMw.zip/metadata.zip/vmware.xml","/CP070391_VMw.zip/metadata.zip/vibs/CP070391-38650740828731168.xml","/CP070391_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070391_3.29.0.3-8.0.0.20613240.xml"],"Name":"CP070391.zip","SHA1Sum":"c4affbd29724756b769155a25662a7aa4dc1cbb6","SHA256Sum":"b7047b0954994fadf48c67e5625d2db9ca3e3fb828fd3a74a2af481bf3d72f71","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"3.29.0","VibList":[{"Name":"CP070391","Version":"3.29.0.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3d40be5189da4a0cb6ac81eeef","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"CP070936.zip","SHA1Sum":"aa7030601a5710b277fbf9811b367a67ff81757e","SHA256Sum":"4d5aaa63f1146ea8641b00586286ec99a42581ba09d23c2d6f875aacd6afd8c7","SHA512Sum":"f44e47bfc9dd27f1c7b0b5ff652f7fe961b09add19689b6896adeef7f6b5ea98b9659dcb0c3e94f361dc5498b72e5df06f0cb1c8b6d584697c21ad2fb97482db"}],"ComponentSizeInKB":19669,"CompsigList":["CP070936.compsig"],"FileList":["/CP070936_BUILD_4.data","/CP070936.vmexe64","/CP070936.vmfile","/CP070936_VMw.zip","/CP070936.xml","/payload.json","/CP070936_VMw.zip/index.xml","/CP070936_VMw.zip/vendor-index.xml","/CP070936_VMw.zip/metadata.zip","/CP070936_VMw.zip/vib20/CP070936/HPE_bootbank_CP070936_HPG2.4-8.0.0.20613240.vib","/CP070936_VMw.zip/metadata.zip/vendor-index.xml","/CP070936_VMw.zip/metadata.zip/vmware.xml","/CP070936_VMw.zip/metadata.zip/vibs/CP070936-5275262355044118200.xml","/CP070936_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070936_HPG2.4-8.0.0.20613240.xml"],"Name":"CP070936.zip","SHA1Sum":"aa7030601a5710b277fbf9811b367a67ff81757e","SHA256Sum":"4d5aaa63f1146ea8641b00586286ec99a42581ba09d23c2d6f875aacd6afd8c7","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2","VibList":[{"Name":"CP070936","Version":"HPG2.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_30274f09155b4fd190f10abc8a","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068754.exe","SHA1Sum":"e69ff50e88568f5169b0c6cfa353b77d81d505bc","SHA256Sum":"bd82062a5d295162781206cd34819a6bf393bbfe0a3b1c3bb9b228f30007649b","SHA512Sum":"d60a102ef4aedb19092b0b760a0d68dba6abb0992a689448d846db7c2dd0ae00962d04af68d90e72b9fd667ae16b015b52a169cf26a8c01fcc47aafd3b7041ff"}],"ComponentSizeInKB":3559,"CompsigList":["cp068754.compsig"],"FileList":["cp068754.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATSATAG1.rel"],"Name":"cp068754.exe","SHA1Sum":"e69ff50e88568f5169b0c6cfa353b77d81d505bc","SHA256Sum":"bd82062a5d295162781206cd34819a6bf393bbfe0a3b1c3bb9b228f30007649b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9dc1ac030cb645d69083765516","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Eth 10/25Gb 2p Sec Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101f159003fe","Version":"26.45.1020"}]},"Files":[{"Checksum":[{"Filename":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","SHA1Sum":"578d4a9d11725775a998f33b3b764d6f3dcbdb95","SHA256Sum":"1988a10fa3d0478665264b56ca84f62f8be4240d70afc595650352aab0a080a8","SHA512Sum":"dbf17703239579cb4d3ae70e730dc706eb39e580bd074eda5b9f2cb190aa6363270d49a3e116d875900b19d50a823f3640539bc0fe67714b3594ac73e0648411"}],"ComponentSizeInKB":6994,"CompsigList":[],"FileList":["26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","26_45_1020-S2A69-63001_Ax_header.pldm.xml","payload.json"],"Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","SHA1Sum":"578d4a9d11725775a998f33b3b764d6f3dcbdb95","SHA256Sum":"1988a10fa3d0478665264b56ca84f62f8be4240d70afc595650352aab0a080a8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"TypeOfChange":"1","Version":"26.45.1020"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_PA_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66bb24ccc3574c59912c4b9116","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0"]},{"OS":"VMware","Version":["8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.deb","SHA1Sum":"ce07b2b28977abe4de3ceeeb2a1a1f6796a23d73","SHA256Sum":"5121286818c03e9f6ec0e1eba1713e5d96611d10cf4f9c4bef320af7e532ed69","SHA512Sum":"c0c10f9dd0f4856d3f6dcf1f5cb777bb3387a66557f278c585dea0120b0d7dcdb9998da1e0db214208ff6479cab2f62a63ccc6122fbedaf11e2e766021bddbd8"}],"ComponentSizeInKB":3527,"CompsigList":["firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/CP071809.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071809.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071809.scexe"],"Name":"firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.deb","SHA1Sum":"ce07b2b28977abe4de3ceeeb2a1a1f6796a23d73","SHA256Sum":"5121286818c03e9f6ec0e1eba1713e5d96611d10cf4f9c4bef320af7e532ed69","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81d63be85ca4491fa746a01bba","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U38_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u38-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"bec70e5657833053ee15749aa96908d840d5e2d6","SHA256Sum":"0a49807de30d94a774652d19081392b62ee36d9004c4bbe1ff5972d56d47fce8","SHA512Sum":"45454564c87efef5bec92e560f574ce24e9de7e24977845a69aa96ab2b14da2e5e7003f459b1d048682dfe0805dd0c071e596075a03063550cbc614bef3bf15c"}],"ComponentSizeInKB":11633,"CompsigList":["firmware-system-u38-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/CP071409.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/U38_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071409.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071409.scexe"],"Name":"firmware-system-u38-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"bec70e5657833053ee15749aa96908d840d5e2d6","SHA256Sum":"0a49807de30d94a774652d19081392b62ee36d9004c4bbe1ff5972d56d47fce8","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26be9e5435ab46b9a4d6238ed8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3815d4b024_0GPK8-2.1_amd64.deb","SHA1Sum":"c1d1510f77c87d42687a0c45b5378592294c6f9f","SHA256Sum":"4058fb08ead3560c09152ff799521d67a5d0b749d20b865bce4638768060710f","SHA512Sum":"9b7a6c4755fd25395de3270f9bcba3e0ad5b1acb84c9095baad3a6641076c1ccf84d0a5ebbd3ae8fb6d1a12f29e445c9eb0cd1df78dd037dd3bdc3dd4c05eb5c"}],"ComponentSizeInKB":4773,"CompsigList":["firmware-hdd-3815d4b024_0GPK8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/CP071774.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071774.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071774.scexe"],"Name":"firmware-hdd-3815d4b024_0GPK8-2.1_amd64.deb","SHA1Sum":"c1d1510f77c87d42687a0c45b5378592294c6f9f","SHA256Sum":"4058fb08ead3560c09152ff799521d67a5d0b749d20b865bce4638768060710f","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67a135eb596544f7afd0ee18b6","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.rpm","SHA1Sum":"33f5249bcfa2d4351f0a5319b7e02d184c3e121a","SHA256Sum":"77d2805bf59ef4af5dc530567717a8ac470d44fb9e4ff4494ae39ae9dc223d7f","SHA512Sum":"95eb8ce6e233e9f836399d492b27a2a397df21668bdeb8b4c6e36496429fa75c8d7de226eb433212f60048ec85234666925ac0c721bbe3710146dd480a09969c"}],"ComponentSizeInKB":108,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.rpm","SHA1Sum":"33f5249bcfa2d4351f0a5319b7e02d184c3e121a","SHA256Sum":"77d2805bf59ef4af5dc530567717a8ac470d44fb9e4ff4494ae39ae9dc223d7f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.rpm","SHA1Sum":"645cd39fdf10ba725f483c4530f6d431b9d58e82","SHA256Sum":"e9ccdab9cc988580ef883bd29bc7a4144c9e84fffc97618503a84d07f3b8e977","SHA512Sum":"76bad06530cf565e5f20b278e6be7decfa60a4e9d30cfb37478049a9cbc56bd4ea18b404a223889b079801a05eb8cc7d31abf3f2b5d1f28e2ab54e6b52624566"}],"ComponentSizeInKB":108,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.rpm","SHA1Sum":"645cd39fdf10ba725f483c4530f6d431b9d58e82","SHA256Sum":"e9ccdab9cc988580ef883bd29bc7a4144c9e84fffc97618503a84d07f3b8e977","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d84b558b0a9948a388dcf8228c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","U46","U46","A43","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069563.exe","SHA1Sum":"dcf43014910c8289908a0f93836dc0c899daf820","SHA256Sum":"5b2a9b056422849549fc7dd49cc6e20c0b6412af461767e728eac623c6f3f84c","SHA512Sum":"c9aa405b6b4341b3b258b5e140c9f95bd1a67096e03d704ebeb24e0c62548a3302884f2441b614b529273eae39e0bbcb44ec3db44d30247e0fc9b3feecf427d7"}],"ComponentSizeInKB":6354,"CompsigList":["cp069563.compsig"],"FileList":["cp069563.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"Name":"cp069563.exe","SHA1Sum":"dcf43014910c8289908a0f93836dc0c899daf820","SHA256Sum":"5b2a9b056422849549fc7dd49cc6e20c0b6412af461767e728eac623c6f3f84c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"InstallationDependency":{},"Name":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1e029bdb27234af1b25a757bd9","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","A47","A48","U38","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","SHA1Sum":"88b7cf0cd5752fc896dd18bc514db5659e8959ca","SHA256Sum":"85dafec3d8c68c68c90eab44b2418b2680c17ebbfabd353a0e027e863d1c21dd","SHA512Sum":"71d342c0dde42a3425a3e05eabf6ec463c59a08adaef1bbcdf91f5403f04687e757a53dbd402aaf6f442d68eb0f3d738334b63ff0998b5f53b2d8b9dc3ac5669"}],"ComponentSizeInKB":5186,"CompsigList":["firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/CP068913.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068913.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068913.scexe"],"Name":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","SHA1Sum":"88b7cf0cd5752fc896dd18bc514db5659e8959ca","SHA256Sum":"85dafec3d8c68c68c90eab44b2418b2680c17ebbfabd353a0e027e863d1c21dd","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1da10066bcaf487dad617cdc66","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b5f7702fda1acbb0280e468ca52f02455ecd10cf","SHA256Sum":"a1a1a2726c5b4d245532cd975b5442bbba8641cb96988a928a3bafa8bc8a0c8a","SHA512Sum":"b09cdc80e7c7dd03ead36536c570626153e9899d6c272c8faa229c2587e01abb5af010d4dfab7be811de41f3406e7b226884f884eb7327e9bea1d25126cd10e3"}],"ComponentSizeInKB":4911,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b5f7702fda1acbb0280e468ca52f02455ecd10cf","SHA256Sum":"a1a1a2726c5b4d245532cd975b5442bbba8641cb96988a928a3bafa8bc8a0c8a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0818951042fb470fada2ce7d5c","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Files":[{"Checksum":[{"Filename":"firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.rpm","SHA1Sum":"dd204678c30030b9031131c7753c7b52ae96b2c6","SHA256Sum":"b6fa70206bed81ce8c0fbfac87d90f2a12cd6fd9b8177fad6aef42d3fb877695","SHA512Sum":"498a2e77029ad03af131cab7e67f68f6527c78d3d8a634604b37b4f74afbea3eaebe3bfa0d3addc976e44518b0146c2e68a3d6efc5b0acb984b620ee3c1a695a"}],"ComponentSizeInKB":10740,"CompsigList":["firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/CP070830.xml","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/Immediate_offset_1.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/Immediate_offset_2.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/OCP_Configuration.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/QSFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/RJ45.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/file_license.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/nvmupdate64e","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/version.txt","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070830.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070830.scexe"],"Name":"firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.rpm","SHA1Sum":"dd204678c30030b9031131c7753c7b52ae96b2c6","SHA256Sum":"b6fa70206bed81ce8c0fbfac87d90f2a12cd6fd9b8177fad6aef42d3fb877695","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"InstallationDependency":{},"Name":"HPE Edgeline X722 NIC Firmware Component for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e91293c3aac24e39a113870b38","SupportedDevices":["a6b1a447-382a-5a4f-8086-37D380860000","a6b1a447-382a-5a4f-8086-37CE80860000","a6b1a447-382a-5a4f-8086-37D180860000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"A40_3.80_05_28_2026.fwpkg","SHA1Sum":"8732d7e6f0a1f75669828e8ae7516935dc4247a6","SHA256Sum":"61260e5779451b1c0ce78c81757e470bcfea20a7f51442b34e6d23a65956a7e0","SHA512Sum":"52e7dea201805f95d30e4b38b0af79b4be1e352697f1b65361c1e1e5e4ebae4832948bf555fec2e3258a54efca73a309895ef0b518c186577465da46c4999643"}],"ComponentSizeInKB":32812,"CompsigList":[],"FileList":["A40_3.80_05_28_2026.signed.flash","A40_3.80_05_28_2026.xml","payload.json"],"Name":"A40_3.80_05_28_2026.fwpkg","SHA1Sum":"8732d7e6f0a1f75669828e8ae7516935dc4247a6","SHA256Sum":"61260e5779451b1c0ce78c81757e470bcfea20a7f51442b34e6d23a65956a7e0","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_02c72a0573f849ad93254c1a37","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069767.exe","SHA1Sum":"963c73b55d3488d9bad718aff1e7741a824557bb","SHA256Sum":"666767566d0a396fec23febc9375d015935e749c5e4f5d67628f9e0a0b06117b","SHA512Sum":"62ed50bf850a161f8ad14cab5de4d4cf7c1eef79ed05285e0e3843058e2e263c1b85af01916fc1df0f3c7a3b60e5b32589ecd7c26de4a06cd2fe3c23f3a1c686"}],"ComponentSizeInKB":755,"CompsigList":["cp069767.compsig"],"FileList":["cp069767.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"Name":"cp069767.exe","SHA1Sum":"963c73b55d3488d9bad718aff1e7741a824557bb","SHA256Sum":"666767566d0a396fec23febc9375d015935e749c5e4f5d67628f9e0a0b06117b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.10.0.1004"}],"InstallationDependency":{},"Name":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_29e86213c3ab4e94b0b54906f7","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","U48","U46","U46","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U60","U61","I45","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U58","U59","U63","I44","U57","U65","U65","U62","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","SHA1Sum":"860c1aa2ec2b50bc8842395e7b15a4215466b410","SHA256Sum":"1840c6ca0deeaf1933ed0fbc31f3a91af570711f63889d0e4dafbfa6522c88ec","SHA512Sum":"24b404cab93c42ff2c4e75623b2f73289702a9e13a3cc1dceb282be89a66f9452f0707a31781b2d7441cbacb4d40d292f13e27e841cefca82385e9fecb22a17e"}],"ComponentSizeInKB":5179,"CompsigList":["firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/CP068904.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068904.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068904.scexe"],"Name":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","SHA1Sum":"860c1aa2ec2b50bc8842395e7b15a4215466b410","SHA256Sum":"1840c6ca0deeaf1933ed0fbc31f3a91af570711f63889d0e4dafbfa6522c88ec","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ad7b70347e749eb8fa34cb98f","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068815.zip","SHA1Sum":"28cdd54eb753052a16ecae15f726a5945289a54b","SHA256Sum":"fbe7c30fdb835272a0103a35685414a0e66f9319811368c3438fbb25ead371ec","SHA512Sum":"2b122f69a4512ddeb2427c531dfe060ba94005a8ae438ead490ce20bfd8e0709e51d9760fb670c66210d66d9abd22ce34c79e619001fb1eb63e7fd1ee103248d"}],"ComponentSizeInKB":581,"CompsigList":["cp068815.compsig"],"FileList":["/cp068815.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/vib20/icen/INT_bootbank_icen_2.3.3.0-1OEM.900.0.24755229.vib","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/icen-8451177904462284908.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-icen_2.3.3.0-1OEM.900.0.24755229.xml"],"Name":"cp068815.zip","SHA1Sum":"28cdd54eb753052a16ecae15f726a5945289a54b","SHA256Sum":"fbe7c30fdb835272a0103a35685414a0e66f9319811368c3438fbb25ead371ec","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"icen","Version":"2.3.3.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.3.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.3.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b50c8b0a8594143bd43ac3e1d","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068734.exe","SHA1Sum":"44e80f8d3e3c47d83a932cccebd85748a9b968ed","SHA256Sum":"f8760e07694a1dd4c515f4962a56ec9d369998810083167f6307ebfeebaf6e14","SHA512Sum":"afd777b1ebc37a7e3b0c913d958d608f8a264f98c544b543ce0933671576d063a88a18a1d2dd61faae5cdafa1c18bcbcf8362a5e395b5079e8a5e2f953ceeee7"}],"ComponentSizeInKB":4263,"CompsigList":["cp068734.compsig"],"FileList":["cp068734.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSSD4.rel"],"Name":"cp068734.exe","SHA1Sum":"44e80f8d3e3c47d83a932cccebd85748a9b968ed","SHA256Sum":"f8760e07694a1dd4c515f4962a56ec9d369998810083167f6307ebfeebaf6e14","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27683fdd56684a358c88bdcb0e","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069517.exe","SHA1Sum":"4a75724a1d957874f5c6a78f9fe72d90061406e3","SHA256Sum":"bc2dcd0cea62dcb64ddff2f0411dffe73bd632cbc640d04c170f7f219666ec0e","SHA512Sum":"4aea0679efdcf7a5d802d7512362975d0b9209d3ba663fce4c0b0f57dbd7d7799676bb5a4de869c081123517b1919e406173143d1f392b5d15b2b73edc7aaff3"}],"ComponentSizeInKB":1058,"CompsigList":["cp069517.compsig"],"FileList":["cp069517.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069517.exe","SHA1Sum":"4a75724a1d957874f5c6a78f9fe72d90061406e3","SHA256Sum":"bc2dcd0cea62dcb64ddff2f0411dffe73bd632cbc640d04c170f7f219666ec0e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03c3b9c44d5a47e2909fe84d5f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"SSDPEL1K375GA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"E2010603.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"E2010603"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","SHA1Sum":"d7c842815b6666c2eec2f0adeafe435f4fc918de","SHA256Sum":"d4b57fa432793af357c31ad29889afda5cf4c7d10543d175327f62f65ea7b8f9","SHA512Sum":"6e57219ee9aa26ff85c283eb6d7ba7adb6303aefc946e1935dd43a88eff6b371430305c1411d9dbc36563da26f4e4428d060ad77cf4cbdd2dee9c1ef0a110264"}],"ComponentSizeInKB":24470,"CompsigList":["firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/CP060386.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas/intelmas.zip","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP060386.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP060386.scexe"],"Name":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","SHA1Sum":"d7c842815b6666c2eec2f0adeafe435f4fc918de","SHA256Sum":"d4b57fa432793af357c31ad29889afda5cf4c7d10543d175327f62f65ea7b8f9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"E2010603"}],"InstallationDependency":{},"Name":"Online Intel Optane SSD Flash Component for Linux - SSDPEL1K375GA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SSDPEL1K375GA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f457b16828314c279f84d52e24","SupportedDevices":["532340a5-4453-4550-4c31-4b3337354741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","9.0","22.04","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"8f0fffab96ea364b2d6ee3c2a0f443c66279bfcf","SHA256Sum":"faec77ce427f2b3dec5c7295c1e1fd326ab21b7a6367f8a016b0b70e689f3cb8","SHA512Sum":"ed0036ea9faa99964f5a804d83cb3f949e7c14bc0b0438cf1a55ebeb721b3027e96678b33f065539b9812a663d97012f236e979ee00a266fc8c3cb0f7585d2e7"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.signed","20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"8f0fffab96ea364b2d6ee3c2a0f443c66279bfcf","SHA256Sum":"faec77ce427f2b3dec5c7295c1e1fd326ab21b7a6367f8a016b0b70e689f3cb8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c3a89bd3dd2e4858859f3d6ee5","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070972.zip","SHA1Sum":"7617d00f94f3721d9fcba842905eea5c2a43ec5b","SHA256Sum":"45c95ba05e3c7e0d91384f9106b4958e7f95ee33440489afbfab55a5f56a75bc","SHA512Sum":"f3abad70db83458bb62d392836ce2db7e8bbca25808f76dc04931a65be0b74fce6a730e607a511bbd99ead34b3662665b643dc50d97a39fe732566f9d3e2dd85"}],"ComponentSizeInKB":19237,"CompsigList":["CP070972.compsig"],"FileList":["/CP070972_BUILD_1.data","/CP070972.vmexe64","/CP070972.vmfile","/CP070972_VMw.zip","/CP070972.xml","/payload.json","/CP070972_VMw.zip/index.xml","/CP070972_VMw.zip/vendor-index.xml","/CP070972_VMw.zip/metadata.zip","/CP070972_VMw.zip/vib20/CP070972/HPE_bootbank_CP070972_HPG3.1-8.0.0.20613240.vib","/CP070972_VMw.zip/metadata.zip/vendor-index.xml","/CP070972_VMw.zip/metadata.zip/vmware.xml","/CP070972_VMw.zip/metadata.zip/vibs/CP070972--2412359239000523884.xml","/CP070972_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070972_HPG3.1-8.0.0.20613240.xml"],"Name":"CP070972.zip","SHA1Sum":"7617d00f94f3721d9fcba842905eea5c2a43ec5b","SHA256Sum":"45c95ba05e3c7e0d91384f9106b4958e7f95ee33440489afbfab55a5f56a75bc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070972","Version":"HPG3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df98f6a135dd46aa8f95ecb57b","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"cp072207.exe","SHA1Sum":"79dc00cc4789616ceb11430105ea95cf14a14af1","SHA256Sum":"78e2e0d5a6397d538b4d5a7b9b06d739b05b2278e997bfd57325d9dc81ab40f2","SHA512Sum":"5a2eb681519a1567444f4887d9003fa4e229b6185b7ea14599a85d598fba0412d690818cf4dd9b985fa112c5eb32cacc1d3d215b3dbabebf7b7e6312da2a912b"}],"ComponentSizeInKB":5026,"CompsigList":["cp072207.compsig"],"FileList":["Config.xml","cp072207.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-6.00-build-000.bin","VDUFlash.dll"],"Name":"cp072207.exe","SHA1Sum":"79dc00cc4789616ceb11430105ea95cf14a14af1","SHA256Sum":"78e2e0d5a6397d538b4d5a7b9b06d739b05b2278e997bfd57325d9dc81ab40f2","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e7b5b08f30ae4968ad47cf785c","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071254.exe","SHA1Sum":"cc6c717cd49042a5569b741613227a2eff08ee6a","SHA256Sum":"424c11a39e26d576d0370a55ea556617f39ac0821e53183ef294574002a938a9","SHA512Sum":"4352d412e16664d3e9c895877b387b931c17953d57cb1e67c1d664c652d11fe98161dcdba0571df65afd9953348cf2ef8fe2621da411b4d6e0271cfd4c8fe621"}],"ComponentSizeInKB":1719,"CompsigList":["cp071254.compsig"],"FileList":["cp071254.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp071254.exe","SHA1Sum":"cc6c717cd49042a5569b741613227a2eff08ee6a","SHA256Sum":"424c11a39e26d576d0370a55ea556617f39ac0821e53183ef294574002a938a9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_127103a853ce4c17a64765cb78","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.deb","SHA1Sum":"3640a936651345a24a49135f4a1993456e6c47de","SHA256Sum":"6fe73bee1dfc0b4855a83263d816d7b3840b128956123d523317c3bd2e8f71af","SHA512Sum":"6bd5b4378a393a550ec008e277bcb0152893f0d7bc6f5d5ca70f200d2a15e3b44590e84466755f1e931deb2c3ed94b9a0ef841914c960bb719085648e8825fb3"}],"ComponentSizeInKB":4525,"CompsigList":["firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/CP071791.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/TAMG09scHPD6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071791.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071791.scexe"],"Name":"firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.deb","SHA1Sum":"3640a936651345a24a49135f4a1993456e6c47de","SHA256Sum":"6fe73bee1dfc0b4855a83263d816d7b3840b128956123d523317c3bd2e8f71af","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f387cbf83e2d4e268bc0acb71f","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072192.exe","SHA1Sum":"a0d80b4f1ad42cabe0e51fe837baf9f017cb7e8a","SHA256Sum":"b629f6675539765a0d32c430ff654ae1638851fc4ff1a50a92b0b9cfb7433dc1","SHA512Sum":"a721394eb12fe5c21c4363fd8d9e452118d21e2d3f463d2b55c68c4c051f46415707943f6a6611f450260c22f789bfb7a74fb2efdf8b15d5618402078ead137c"}],"ComponentSizeInKB":2435,"CompsigList":["cp072192.compsig"],"FileList":["cp072192.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072192.exe","SHA1Sum":"a0d80b4f1ad42cabe0e51fe837baf9f017cb7e8a","SHA256Sum":"b629f6675539765a0d32c430ff654ae1638851fc4ff1a50a92b0b9cfb7433dc1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc488ae5b86e4518a83dc06d30","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007","a6b1a447-382a-5a4f-15b3-101e15b30012"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"cp072205.exe","SHA1Sum":"b60be39524fcc1ea60645b0154b230dadfb4e02d","SHA256Sum":"63b4cc7429a4f83e20088bc964e091068f02790f7ba5b3d5c6dfefaf2612a0ca","SHA512Sum":"7e1acddd61e9965eed631aabe22d4eecd4ba2002914e97bc02375dd2c8de214302de72b70398acb3c1bf7584d46461581c1c98419aa73b55ee7c318c66f23852"}],"ComponentSizeInKB":5002,"CompsigList":["cp072205.compsig"],"FileList":["Config.xml","cp072205.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"Name":"cp072205.exe","SHA1Sum":"b60be39524fcc1ea60645b0154b230dadfb4e02d","SHA256Sum":"63b4cc7429a4f83e20088bc964e091068f02790f7ba5b3d5c6dfefaf2612a0ca","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2972f8783d574ccebb8ad683e0","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.37.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-2.43.0-1.1.x86_64.rpm","SHA1Sum":"3d8dc3b71bcea21721e6f060c0472d1f3dc751d9","SHA256Sum":"289266279d1624605623a16218a1ad1c7edf70eaa1acb65c38f7c4af8c7d6bd7","SHA512Sum":"7069118f34bc63f9226d2b0221f1703b94074c7dbedd6655851c959d3b73a8a1be995373d3e6b91be3a5955d8274973273a1b2ba7af4d53c28a2d70c92131922"}],"ComponentSizeInKB":6652,"CompsigList":["firmware-nic-bcm-2.43.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/CP071590.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/CP071590.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.43.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071590.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071590.scexe"],"Name":"firmware-nic-bcm-2.43.0-1.1.x86_64.rpm","SHA1Sum":"3d8dc3b71bcea21721e6f060c0472d1f3dc751d9","SHA256Sum":"289266279d1624605623a16218a1ad1c7edf70eaa1acb65c38f7c4af8c7d6bd7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"2.43.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eddf5183db024424ac1628a449","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072362.zip","SHA1Sum":"58a578554b5ac2001a4ccbd6380efadfce37cf49","SHA256Sum":"b3544708463c59214b4e00246daa417a97020722d70e9f18c69bf17bf5f8614b","SHA512Sum":"58da7645fbe799b2156a4219561ece1aa01137db445f1c847637d5c44e75456cd47ac6a1133a81b06e5e20fdadc78487e2198fdacaa8cd7371116241fb2e7853"}],"ComponentSizeInKB":22795,"CompsigList":["CP072362.compsig"],"FileList":["/CP072362.xml","/CP072362_VMw.zip","/payload.json","/CP072362.vmexe64","/CP072362.vmfile","/CP072362_VMw.zip/index.xml","/CP072362_VMw.zip/vendor-index.xml","/CP072362_VMw.zip/metadata.zip","/CP072362_VMw.zip/vib20/CP072362/HPE_bootbank_CP072362_1.0.2-1OEM.900.0.24755229.vib","/CP072362_VMw.zip/metadata.zip/vendor-index.xml","/CP072362_VMw.zip/metadata.zip/vmware.xml","/CP072362_VMw.zip/metadata.zip/vibs/CP072362-3589829479576141667.xml","/CP072362_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072362_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072362.zip","SHA1Sum":"58a578554b5ac2001a4ccbd6380efadfce37cf49","SHA256Sum":"b3544708463c59214b4e00246daa417a97020722d70e9f18c69bf17bf5f8614b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072362","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d98fa56154f5469eb77d87f26f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","SHA1Sum":"640c0e7e027bdc1c0daf4e7ecc77e1c4d443e386","SHA256Sum":"8ef4645dd66200255d41b97ab89a0b3d6e9cd02a618ba7134dafc9cb85237d05","SHA512Sum":"2b05ed68566ab8ac388d7655e218e9fec4fc95f51b325cc5ddb80be75890d1b003da0d24a08a86eaca5ca5a995961b4de99774418bdabb42a4ee4afc02a26bc5"}],"ComponentSizeInKB":5820,"CompsigList":["firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/CP068924.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068924.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068924.scexe"],"Name":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","SHA1Sum":"640c0e7e027bdc1c0daf4e7ecc77e1c4d443e386","SHA256Sum":"8ef4645dd66200255d41b97ab89a0b3d6e9cd02a618ba7134dafc9cb85237d05","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a01b30d9ab32481babdfa599e5","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","SHA1Sum":"330bbaabe9ea4da638b0301a24cc757a34721257","SHA256Sum":"7d3e46811527af7da5b4e1d2ff79b78196b9fe5562ea3119ee25797af0bd25ef","SHA512Sum":"461b68dd818602275cecc459d56baa88c458aa386a94be3b9a9645a1b2c3920655329f7fc8dc47cfdd9d07cff3bbec3492417b2b9dc57a2cd6272268386e5709"}],"ComponentSizeInKB":6063,"CompsigList":["firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/CP068931.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068931.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068931.scexe"],"Name":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","SHA1Sum":"330bbaabe9ea4da638b0301a24cc757a34721257","SHA256Sum":"7d3e46811527af7da5b4e1d2ff79b78196b9fe5562ea3119ee25797af0bd25ef","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27009a68f379417b83776e4d99","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070317.exe","SHA1Sum":"745c11fd0a5ad847bb9828118c5dd2b5a3e7e430","SHA256Sum":"356b6eaf5017f0da75d2df098f746e5e5f778e4065ac34e72f62c85b50201019","SHA512Sum":"54ee43de41de6dd0423e8c5a04a7eeda209a09b93f07e7146af70feba2cb91ecbf852f158f7d70efbbcdd1df9926dfbce501d8e87f280846d43ea223eb3a7684"}],"ComponentSizeInKB":4202,"CompsigList":["cp070317.compsig"],"FileList":["cp070317.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.1-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp070317.exe","SHA1Sum":"745c11fd0a5ad847bb9828118c5dd2b5a3e7e430","SHA256Sum":"356b6eaf5017f0da75d2df098f746e5e5f778e4065ac34e72f62c85b50201019","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.1"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42c244c364564278b0d9a491f3","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"Files":[{"Checksum":[{"Filename":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","SHA512Sum":"6afe5f6af017b457e9b1998f3b3dc2320d64fd717d7bb6547fd513ec1f0c604ff489f24eeb1c6efdaa66076a64c4e045cbd12a614099d943c1890e7ec12850cb"}],"ComponentSizeInKB":37,"CompsigList":[],"FileList":["ISS_NVMe_BP_PIC_flashV1B24.xml","ISS_NVMe_BP_PIC_flashV1B24_signed.hex","payload.json"],"Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"TypeOfChange":"1","Version":"1.24"}],"InstallationDependency":{},"Name":"Firmware Package - Gen10 NVMe Backplane PIC Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"NVMePIC-Gen10","SWKeyExpectedPath":"firmware:nvmebackplane"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd4644ff6898456b8bf5d3a92e","SupportedDevices":["00000000-0000-0000-0000-00004e564d65"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U36","U41","U40","U45","U37","U38","U38","I43","I42","A43"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7f2a26e6d0_0HPG1-2.1_amd64.deb","SHA1Sum":"daf7fdde361351261ed5ea2eb4a79e9b5a088318","SHA256Sum":"8ba0bacdaa75d07812d52eaae66af23d72a7000805727d31615cf46b4d9c3554","SHA512Sum":"1d217d0243063cc9f94ba79775c8dffa4f182f3a5fbf4d94b18132edb4e21825ca48f4b1621b9e250adf59200500fa93b86cc5d4197cc077e9a9255d44d77fef"}],"ComponentSizeInKB":4650,"CompsigList":["firmware-hdd-7f2a26e6d0_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/CP071779.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071779.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071779.scexe"],"Name":"firmware-hdd-7f2a26e6d0_0HPG1-2.1_amd64.deb","SHA1Sum":"daf7fdde361351261ed5ea2eb4a79e9b5a088318","SHA256Sum":"8ba0bacdaa75d07812d52eaae66af23d72a7000805727d31615cf46b4d9c3554","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a6927c3636f4311a34ae300df","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A42_4.04_04_02_2026.fwpkg","SHA1Sum":"2369c9dbad0b2101310797f035db3daef96b39d0","SHA256Sum":"70d7f0a2f6a481c650000cb4c160736712a689f1a05dddfe345b604175a95cce","SHA512Sum":"ea7de6fdb4fa6d05e020e65962784c0000f37a4f08de5cd19d59d133bdb022a9059cb993d28fd46a9d496eaaae08edcaaa1b003f0aa14d0151c21bd40c8fd24e"}],"ComponentSizeInKB":32818,"CompsigList":[],"FileList":["A42_4.04_04_02_2026.signed.flash","A42_4.04_04_02_2026.xml","payload.json"],"Name":"A42_4.04_04_02_2026.fwpkg","SHA1Sum":"2369c9dbad0b2101310797f035db3daef96b39d0","SHA256Sum":"70d7f0a2f6a481c650000cb4c160736712a689f1a05dddfe345b604175a95cce","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58ffaedc5e374be8b114e80a14","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071395.exe","SHA1Sum":"17dcb7e1d04e2537c69d63a81d62af94f4b0ecf7","SHA256Sum":"6c63a293b457ca5ce201be71583ca4578c48536be9cc4c3836df4af9a91c7c57","SHA512Sum":"43abb27f05fa20b50c683b6efc0484338732cbe0e9fb54cb19fd1e48280e8444c314dcc648318456e22f0d93ab8c87dec0fdf62b4ff1284b2692510008f028ff"}],"ComponentSizeInKB":11649,"CompsigList":["cp071395.compsig"],"FileList":["cp071395.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_3.66_04_01_2026.signed.flash"],"Name":"cp071395.exe","SHA1Sum":"17dcb7e1d04e2537c69d63a81d62af94f4b0ecf7","SHA256Sum":"6c63a293b457ca5ce201be71583ca4578c48536be9cc4c3836df4af9a91c7c57","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f70cdce434ba434b95f66dbbd1","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U40_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U40_3.66_04_01_2026.fwpkg","SHA1Sum":"da68e61d1dd6282604fef10162b15bb191f2883c","SHA256Sum":"b346372812931b3474c8fb5811c370f6f623ec99b98a7dd8096d8a19cbbcac60","SHA512Sum":"f3020ec1c31498f2287a31dbe1fedbbfce69e5776a0f15c01702e87b3e43d243e9732cc669a17e6e16a8fc47f9f4fdded220e99a0ccdef84de54f9832856b114"}],"ComponentSizeInKB":32822,"CompsigList":[],"FileList":["payload.json","U40_3.66_04_01_2026.signed.flash","U40_3.66_04_01_2026.xml"],"Name":"U40_3.66_04_01_2026.fwpkg","SHA1Sum":"da68e61d1dd6282604fef10162b15bb191f2883c","SHA256Sum":"b346372812931b3474c8fb5811c370f6f623ec99b98a7dd8096d8a19cbbcac60","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5abb6dbc375d486fb86bee31a4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.rpm","SHA1Sum":"96e69ad710f39b2d9f9453a622a9ede92c5a1e04","SHA256Sum":"a58de6ead5c4a03aaa4f1c04989a6bf38b910fd1492414d56c09250358d1264d","SHA512Sum":"a239d890a2c628a1b26554f464fec5669dee973b0ad83998ee2676460129397d347d9b34bb1b2c918989a43cf188abf613dfbf5a0b65e9ef3c110c374d2d661d"}],"ComponentSizeInKB":9614,"CompsigList":["firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/CP072398.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072398.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072398.scexe"],"Name":"firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.rpm","SHA1Sum":"96e69ad710f39b2d9f9453a622a9ede92c5a1e04","SHA256Sum":"a58de6ead5c4a03aaa4f1c04989a6bf38b910fd1492414d56c09250358d1264d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42a5424fc6714cbeb6b3632056","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","12.0","15.0","16.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0f705d7c02b00387039f0de0a773ede33ff1cc05","SHA256Sum":"0f810a90bc2c9b16202fb6e50e1bd12d91ac2dc8ef58fc7747e7ac11dbeacb66","SHA512Sum":"e2f19bbd5ddb095a00eec62e8b3128b1dddb9eb3c97000f6716b7fefc3e3d5ffbf48658a4f72e592805e4a922424bd3ecb208045a0595ed45dd2a707b806c355"}],"ComponentSizeInKB":783,"CompsigList":["elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0f705d7c02b00387039f0de0a773ede33ff1cc05","SHA256Sum":"0f810a90bc2c9b16202fb6e50e1bd12d91ac2dc8ef58fc7747e7ac11dbeacb66","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.6"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3be72de3c7ed4d1b94905d0eb7","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP072337.zip","SHA1Sum":"d30e8d85d47d2d8e7c4458cd83840c9befa09b64","SHA256Sum":"09d496dd5fd9e0ada16cd834fc53156608be7a6dabe0efcfd77b8870b26a401c","SHA512Sum":"a556f138b06c2305eb907c2aa2b9cd4079dc0a39b1be1ce52c4883d041f84bcbd5820039f9adc79bea67e7bf5c70b39cd7ac1b4acf3791d9956971b1a6cbf358"}],"ComponentSizeInKB":19948,"CompsigList":["CP072337.compsig"],"FileList":["/CP072337_BUILD_3.data","/CP072337.vmexe64","/CP072337.vmfile","/CP072337_VMw.zip","/CP072337.xml","/payload.json","/CP072337_VMw.zip/index.xml","/CP072337_VMw.zip/vendor-index.xml","/CP072337_VMw.zip/metadata.zip","/CP072337_VMw.zip/vib20/CP072337/HPE_bootbank_CP072337_HPD5.3-8.0.0.20613240.vib","/CP072337_VMw.zip/metadata.zip/vendor-index.xml","/CP072337_VMw.zip/metadata.zip/vmware.xml","/CP072337_VMw.zip/metadata.zip/vibs/CP072337-2721442525364836120.xml","/CP072337_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072337_HPD5.3-8.0.0.20613240.xml"],"Name":"CP072337.zip","SHA1Sum":"d30e8d85d47d2d8e7c4458cd83840c9befa09b64","SHA256Sum":"09d496dd5fd9e0ada16cd834fc53156608be7a6dabe0efcfd77b8870b26a401c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"2","Version":"HPD5","VibList":[{"Name":"CP072337","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e06c8024986747a4a23292afc5","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070836.zip","SHA1Sum":"f6a5c835371f83caf4e4032c03d14b2df58d85eb","SHA256Sum":"ab246757832935e805e158c16b072e09b63449d5f9784d787e8b845f0cf819f8","SHA512Sum":"0f38b03aa36d0f4a69b6fbd39c4851710ab6112aa0e28e64e9e0c53edb9e8dedc286c4e805930fe10ecaf97687c8a59ffbb8722cc2a3903c37b791015699f88d"}],"ComponentSizeInKB":16261,"CompsigList":["CP070836.compsig"],"FileList":["/CP070836_BUILD_5.data","/CP070836.vmexe64","/CP070836.vmfile","/CP070836_VMw.zip","/CP070836.xml","/payload.json","/CP070836_VMw.zip/index.xml","/CP070836_VMw.zip/vendor-index.xml","/CP070836_VMw.zip/metadata.zip","/CP070836_VMw.zip/vib20/CP070836/HPE_bootbank_CP070836_HPG5.5-8.0.0.20613240.vib","/CP070836_VMw.zip/metadata.zip/vendor-index.xml","/CP070836_VMw.zip/metadata.zip/vmware.xml","/CP070836_VMw.zip/metadata.zip/vibs/CP070836--6060580474925906781.xml","/CP070836_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070836_HPG5.5-8.0.0.20613240.xml"],"Name":"CP070836.zip","SHA1Sum":"f6a5c835371f83caf4e4032c03d14b2df58d85eb","SHA256Sum":"ab246757832935e805e158c16b072e09b63449d5f9784d787e8b845f0cf819f8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070836","Version":"HPG5.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1b1a70ed4f854fe5b5518a7d13","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3330-3834-3047574a504b","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3234-3047574a5044"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068739.exe","SHA1Sum":"f504b1a99ed489c0d59054d9fef246ee33ba9c13","SHA256Sum":"6518d6c36ee3fcd9bf2eb8e64c03d39dc5258b19854754723bd4f9f9045cb357","SHA512Sum":"cf139036ef406edbbe6cb0746349d2f14011ca0f5ce439c4963707e94f193d719cdfa4239851b212eafa2fdeb798ea75c987d55b48dad78d7a210336df4fa00b"}],"ComponentSizeInKB":4262,"CompsigList":["cp068739.compsig"],"FileList":["cp068739.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKESD3.rel"],"Name":"cp068739.exe","SHA1Sum":"f504b1a99ed489c0d59054d9fef246ee33ba9c13","SHA256Sum":"6518d6c36ee3fcd9bf2eb8e64c03d39dc5258b19854754723bd4f9f9045cb357","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03a98050888847a781c6cde05e","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071901.exe","SHA1Sum":"f82faba6630eaaf2b8be098c0e9f3788d0af2a87","SHA256Sum":"e45c822a0e7d8729b27415a8eaa8f624598386afc03b565fe7006c485ec8733e","SHA512Sum":"ec072616b6d2706c78a8a6772a6a2d81ecb113ab6a24ea14cf3e81febb95292996688253397d72a28b5b062936d05f1708a51b8250efec355cde62a919390ea3"}],"ComponentSizeInKB":790,"CompsigList":["cp071901.compsig"],"FileList":["cp071901.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"Name":"cp071901.exe","SHA1Sum":"f82faba6630eaaf2b8be098c0e9f3788d0af2a87","SHA256Sum":"e45c822a0e7d8729b27415a8eaa8f624598386afc03b565fe7006c485ec8733e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.38.0.1003"}],"InstallationDependency":{},"Name":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2022 and Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa741ed6213f4d85b53532d541","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","U48","U46","U46","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U60","U61","I45","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U58","U59","U63","I44","U57","U65","U65","U62","U71","A66","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm","SHA1Sum":"2785e96d452cfe1b53ce880c92975008e22db2a6","SHA256Sum":"e82c6c8ab60065f632e6dfd74d4a0be32105b465cd35b0c0c6f1ff8487874c8a","SHA512Sum":"4fb2b82b1f87de91f8cfe76ff5c2b7dbe2709044d95ee0d4f651dfa17c184394aac8dacf8c6d476c0e0306442128dfbb3fe7ee95fa5ada138330c2e65c8b3d31"}],"ComponentSizeInKB":9993,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.8.84","./usr/share/doc/packages/libvma-9.8.84/CHANGES","./usr/share/doc/packages/libvma-9.8.84/README","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm","SHA1Sum":"2785e96d452cfe1b53ce880c92975008e22db2a6","SHA256Sum":"e82c6c8ab60065f632e6dfd74d4a0be32105b465cd35b0c0c6f1ff8487874c8a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm","SHA1Sum":"147d380f7e9d9410b04c21aebcff26391bf174c0","SHA256Sum":"78312145a1476bb9ed79ad1c073dd9369c79d483298baccf62b16368950483b9","SHA512Sum":"64f97ad98abac4af587c2a8dabf9d6f5f59ff8c7126145c32d425008fd17551d846cf74626c30941299eb72ef11bd50ddbe3d1d072c09271c1cc692a8b23df82"}],"ComponentSizeInKB":2645,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/compat","./lib/modules/6.4.0-150700.51-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/block","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150700.51-default/updates/net","./lib/modules/6.4.0-150700.51-default/updates/net/9p","./lib/modules/6.4.0-150700.51-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150700.51-default/updates/net/rds","./lib/modules/6.4.0-150700.51-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm","SHA1Sum":"147d380f7e9d9410b04c21aebcff26391bf174c0","SHA256Sum":"78312145a1476bb9ed79ad1c073dd9369c79d483298baccf62b16368950483b9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2762e93953d647638bb9c4b657","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Files":[{"Checksum":[{"Filename":"CP070386.zip","SHA1Sum":"537947b34f6ba6c79b7e0594b64191ee5d594767","SHA256Sum":"4b9ae405e41bcc1e25a9e462bd66aaccfd9a7d817226b6762a7b34ade254a7a0","SHA512Sum":"ce211860cbae47ecbba6cb00a0393a938af44b8b628b26d0fa08d675823bc5d95920bcfd3b49681d59714a4a230f3c3c109a862e4e177ea7d3e906c43a339ab4"}],"ComponentSizeInKB":10534,"CompsigList":["CP070386.compsig"],"FileList":["/CP070386_BUILD_5.data","/CP070386.vmexe64","/CP070386.vmfile","/CP070386_VMw.zip","/CP070386.xml","/payload.json","/CP070386_VMw.zip/index.xml","/CP070386_VMw.zip/vendor-index.xml","/CP070386_VMw.zip/metadata.zip","/CP070386_VMw.zip/vib20/CP070386/HPE_bootbank_CP070386_4.20.0.5-8.0.0.20613240.vib","/CP070386_VMw.zip/metadata.zip/vendor-index.xml","/CP070386_VMw.zip/metadata.zip/vmware.xml","/CP070386_VMw.zip/metadata.zip/vibs/CP070386--6330568369180863444.xml","/CP070386_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070386_4.20.0.5-8.0.0.20613240.xml"],"Name":"CP070386.zip","SHA1Sum":"537947b34f6ba6c79b7e0594b64191ee5d594767","SHA256Sum":"4b9ae405e41bcc1e25a9e462bd66aaccfd9a7d817226b6762a7b34ade254a7a0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"4.20.0","VibList":[{"Name":"CP070386","Version":"4.20.0.5-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_87b6eb9982bc4a72811586d55f","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"CP072400.zip","SHA1Sum":"65c67e6c47774941d42dfc5f07a9beb6ad9f45d2","SHA256Sum":"1e77f17d1245eb1f586b8f2395e6c455474265dc5fbc5ab8f803f3f9bd7ac15d","SHA512Sum":"3a4c9f5acf9fc4545640ee159b87293fa44f988f59aeb039fe4cf94b8fa12fa82349c5f01e92219e784600c160bd33d1264f59dcbff2be420c1d03038100c197"}],"ComponentSizeInKB":24976,"CompsigList":["CP072400.compsig"],"FileList":["/CP072400.xml","/CP072400_VMw.zip","/payload.json","/CP072400.vmexe64","/CP072400.vmfile","/CP072400_VMw.zip/index.xml","/CP072400_VMw.zip/vendor-index.xml","/CP072400_VMw.zip/metadata.zip","/CP072400_VMw.zip/vib20/CP072400/HPE_bootbank_CP072400_1.0.2-1OEM.900.0.24755229.vib","/CP072400_VMw.zip/metadata.zip/vendor-index.xml","/CP072400_VMw.zip/metadata.zip/vmware.xml","/CP072400_VMw.zip/metadata.zip/vibs/CP072400--3093516677357361105.xml","/CP072400_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072400_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072400.zip","SHA1Sum":"65c67e6c47774941d42dfc5f07a9beb6ad9f45d2","SHA256Sum":"1e77f17d1245eb1f586b8f2395e6c455474265dc5fbc5ab8f803f3f9bd7ac15d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072400","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.x","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2484286db1447d6a8c5001d4e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070937.zip","SHA1Sum":"da303b2c21ace83675eb0befe674404003fd1d55","SHA256Sum":"7caa72d7012d22cc83a460754705ae9e1d62afafe6c7d2ff2cf6d4022745539b","SHA512Sum":"63361e2efcc6ccf4020d9f65a0ca3a79ec6c2ccf8c63f69409945bf7ac4a641b98b4b9440bc63f82eeb27f914e884b49bec3436b59f212a7184cbb5875fdd6a2"}],"ComponentSizeInKB":17658,"CompsigList":["CP070937.compsig"],"FileList":["/CP070937_BUILD_4.data","/CP070937.vmexe64","/CP070937.vmfile","/CP070937_VMw.zip","/CP070937.xml","/payload.json","/CP070937_VMw.zip/index.xml","/CP070937_VMw.zip/vendor-index.xml","/CP070937_VMw.zip/metadata.zip","/CP070937_VMw.zip/vib20/CP070937/HPE_bootbank_CP070937_HPD6.4-8.0.0.20613240.vib","/CP070937_VMw.zip/metadata.zip/vendor-index.xml","/CP070937_VMw.zip/metadata.zip/vmware.xml","/CP070937_VMw.zip/metadata.zip/vibs/CP070937--6928732070771402113.xml","/CP070937_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070937_HPD6.4-8.0.0.20613240.xml"],"Name":"CP070937.zip","SHA1Sum":"da303b2c21ace83675eb0befe674404003fd1d55","SHA256Sum":"7caa72d7012d22cc83a460754705ae9e1d62afafe6c7d2ff2cf6d4022745539b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070937","Version":"HPD6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_da389c98853b4e2ca18e5a964c","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900455","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.2.14.1031"},{"DeviceName":"HPE_NS204i_1.2.14.1031","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_NS204i_1.2.14.1031_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.2.14.1031"}]},"Files":[{"Checksum":[{"Filename":"HPE_NS204i_1.2.14.1031_A.fwpkg","SHA1Sum":"543361b61bae13bb06816489e95b052e8507893d","SHA256Sum":"11af5a3b58bba3be7f01351c0cd3856862911395f2f1e873d954bba82f3323e6","SHA512Sum":"d972d5932b898f751d0b23e7949a45fbed4b3357adf35606fc888b6dc273f65022abfc28ea62d324347e8743b80cc536b2ce08ee749d19a564a9aebb2ee58e73"}],"ComponentSizeInKB":7209,"CompsigList":[],"FileList":["HPE_NS204i_1.2.14.1031_A.HPb","HPE_NS204i_1.2.14.1031_A.xml","payload.json"],"Name":"HPE_NS204i_1.2.14.1031_A.fwpkg","SHA1Sum":"543361b61bae13bb06816489e95b052e8507893d","SHA256Sum":"11af5a3b58bba3be7f01351c0cd3856862911395f2f1e873d954bba82f3323e6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900455","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"TypeOfChange":"1","Version":"1.2.14.1031"}],"InstallationDependency":{},"MinimumActiveVersion":"1.2.14.1018","Name":"Firmware Package - HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"03791590","SWKeyExpectedPath":"firmware"},{"Name":"03801590","SWKeyExpectedPath":"firmware"},{"Name":"02F61590","SWKeyExpectedPath":"firmware"},{"Name":"030E1590","SWKeyExpectedPath":"firmware"},{"Name":"04551590","SWKeyExpectedPath":"firmware"},{"Name":"030F1590","SWKeyExpectedPath":"firmware"},{"Name":"03101590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90d3bb7036e94d928e759a85d1","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900455","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-22411590030f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","I45","U58","U58","U54","U58","U54","U54","U63","U59","U63","U34","U34","A42","U46","U30","A42","U46","U32","A43","A43","A43","U41","U33","A47","A48","U47","A46","U47","U48","U40","U50","U39","I44","A42","H10","U61","U60","H10","H10","U46","U65","U65","U69","U69","I46","H11","U72","U68","U68","U68","U70","HPE Cray XD665","U68","A66","A66","U72","U71","A59"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-237.1.137.0-rhel10u1.x86_64.rpm","SHA1Sum":"5f8bd8cc8d71f00d4c0285a29db53fefa9c0f1e0","SHA256Sum":"30a9502c6f0ee9687f395cd71e617302408e53ccb2f8938bec4ac67a64136dc4","SHA512Sum":"2769e53a415620befbc9ef86b177f33969c6cb73b6f77cba0a22a27dd8ad705c904d848c1fbaf16072c28b92da37987aed0860e40f17fa7acc49bcaf7e662f2f"}],"ComponentSizeInKB":58,"CompsigList":["libbnxt_re-237.1.137.0-rhel10u1.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/d8e12b7e530f1900bfaf30ed4b08f52fb074ca","./usr/lib64/libbnxt_re-237.1.137.0.so","./usr/lib64/libbnxt_re-rdmav57.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-237.1.137.0-rhel10u1.x86_64.rpm","SHA1Sum":"5f8bd8cc8d71f00d4c0285a29db53fefa9c0f1e0","SHA256Sum":"30a9502c6f0ee9687f395cd71e617302408e53ccb2f8938bec4ac67a64136dc4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 1.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4917803ade414846a622dcb7be","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"cp071322.exe","SHA1Sum":"94ccdf5231323f34e86d5c766e1cd93783a9e0ad","SHA256Sum":"1e30444871324d166c9d0565d3e9864c8dffea413921996956eb8f2d3d8f9609","SHA512Sum":"44f51e9decd1a370feb1bd741feef25a518d769b1ea5adffc1b7e0cb6a2a0211735b10cb38d648ce411360da600a9aa5f72ca8bfd6111fbf34a39c9c3c11aafc"}],"ComponentSizeInKB":4505,"CompsigList":["cp071322.compsig"],"FileList":["cp071322.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.21-1/firmware/","elxflashStandalone-windows-14.4.731.21-1/firmware/B14473121.grp","elxflashStandalone-windows-14.4.731.21-1/firmware/P14473121.grp","elxflashStandalone-windows-14.4.731.21-1/win/","elxflashStandalone-windows-14.4.731.21-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.21-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.21-1/win/x64/","elxflashStandalone-windows-14.4.731.21-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.21-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.21-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.21-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.21-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.21-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.21-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp071322.exe","SHA1Sum":"94ccdf5231323f34e86d5c766e1cd93783a9e0ad","SHA256Sum":"1e30444871324d166c9d0565d3e9864c8dffea413921996956eb8f2d3d8f9609","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2022 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aea906ca0bf04368b611496846","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071593.exe","SHA1Sum":"3e7df758b8ee11bddaa7b67893dadeef288615cf","SHA256Sum":"9f6e2ab3a744fc156f3032ea75014e9b8c0f925c42c69a3f1239962d139f86bd","SHA512Sum":"03dd836a5dc06ea7d9334d8d80247c755554f8612403027cbaeead2d6f09a642cfc64701618fd693894d87e0c31996fc9fe814e554a38cd70e73b3d0384ca95f"}],"ComponentSizeInKB":948,"CompsigList":["cp071593.compsig"],"FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp071593.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071593.exe","SHA1Sum":"3e7df758b8ee11bddaa7b67893dadeef288615cf","SHA256Sum":"9f6e2ab3a744fc156f3032ea75014e9b8c0f925c42c69a3f1239962d139f86bd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.10.0"}],"InstallationDependency":{},"Name":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_261371c49c154d01a75120cbff","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U54","U54","U56","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","A59","U72","U70","U72","U68","A66","A66","U77","03030202"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.deb","SHA1Sum":"55f7131d60767dcff89f26d313b50f7aeb1cfa8b","SHA256Sum":"0a23fa7a8deb5eb39611ff48c6e9d8533eec5e1d4bfd6b4a6f161ec0ee133f21","SHA512Sum":"de4505e3abf844eee80d8e09621cad9ed0322abf043fb6991bc158e95c353455c79149c86b9bef3db4475c715011968386ed60760b8e3bedfe3a9b46ec13fb60"}],"ComponentSizeInKB":3578,"CompsigList":["firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/CP072236.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/M52002TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072236.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072236.scexe"],"Name":"firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.deb","SHA1Sum":"55f7131d60767dcff89f26d313b50f7aeb1cfa8b","SHA256Sum":"0a23fa7a8deb5eb39611ff48c6e9d8533eec5e1d4bfd6b4a6f161ec0ee133f21","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f1dc40e25bb748459312d9e04e","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U37_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071399.exe","SHA1Sum":"861a4e136cc56b00a5291e4568dcfb4487f9100a","SHA256Sum":"923f76f30c8bbc4215ae78abfd3f5cc292eb64f4d6d33ee10c8281d3dac8340f","SHA512Sum":"c08791c417ef5c8ddd7aef7521f6a8697fae5e06fe7e84910d434ba39f19532f3794b644b9f1a0ecd0d65506c1a74b41fde2786f5822a96ffa379b6ec0c7f9f9"}],"ComponentSizeInKB":11339,"CompsigList":["cp071399.compsig"],"FileList":["cp071399.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_3.66_04_01_2026.signed.flash"],"Name":"cp071399.exe","SHA1Sum":"861a4e136cc56b00a5291e4568dcfb4487f9100a","SHA256Sum":"923f76f30c8bbc4215ae78abfd3f5cc292eb64f4d6d33ee10c8281d3dac8340f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b0e5d6a65ef041808f51aba3e8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.rpm","SHA1Sum":"cdefdfd9dd6b84c7fb27d44bd8e16ec029ac894d","SHA256Sum":"342d50525c1774429799a9bf6e32f1ca7932ce4f2a3f433444f1986a437164f8","SHA512Sum":"b4be3472a04e92bd5af177828f83612be1429d84c7f8065990ea29f0bea1d93d66889598f66b7b5e18360619e6b2bee8c101059bc86aa7b6404317c2d58c774b"}],"ComponentSizeInKB":105,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/26","./usr/lib/.build-id/26/e9067561782d0a333267c894be04e55a12adae","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.rpm","SHA1Sum":"cdefdfd9dd6b84c7fb27d44bd8e16ec029ac894d","SHA256Sum":"342d50525c1774429799a9bf6e32f1ca7932ce4f2a3f433444f1986a437164f8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.rpm","SHA1Sum":"7f222a06553851eda39d9fbae82ba34ee437cf73","SHA256Sum":"ec1e4fe7ceb338243fdb40416ae2d81cb5e04020788766d5aa95d0378906fd9d","SHA512Sum":"ee6de5b6c3e3243a25fa9fd18d02449389c14dbc4c38cf020896cff0b136784b983783d00039d1d1767e65c6cbadb516f7b2246577943fcaf32d8339f3e136f2"}],"ComponentSizeInKB":112,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/smartpqi","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/e0e8e0426e1533fa14b7726280b4f746c2f833","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.rpm","SHA1Sum":"7f222a06553851eda39d9fbae82ba34ee437cf73","SHA256Sum":"ec1e4fe7ceb338243fdb40416ae2d81cb5e04020788766d5aa95d0378906fd9d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 9 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d90f018f760941ecab340cd568","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","HPE Apollo 2000 Gen10 Plus System","A42","U46","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","A43","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles16sp0-1.x86_64.rpm","SHA1Sum":"e80c179c759435be726779c55438b1da28f6f140","SHA256Sum":"c469290e9512595b67303573b29d7cdfa3b3f839f6e674abededbdaad81a9bca","SHA512Sum":"9c5221fabdb320b3c9eb39eeb174038459c4bf07a924bbf68ea320a431ce7afd639836a6bbfe2adea4dbe9030c1d261950737c9a60df6eef356c00ce0ea7c144"}],"ComponentSizeInKB":901,"CompsigList":["lsi-megaraid_sas-kmp-default-07.736.04.00_sles16sp0-1.x86_64.compsig"],"FileList":["./usr/lib/.build-id","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/594a2a1d6f42dac64f5dab53efb3d7600e513e","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles16sp0-1.x86_64.rpm","SHA1Sum":"e80c179c759435be726779c55438b1da28f6f140","SHA256Sum":"c469290e9512595b67303573b29d7cdfa3b3f839f6e674abededbdaad81a9bca","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.736.04.00"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9e68ffb9ef034e4885fccaf4a1","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U58","U54","U58","U63","U54","U54","U61","U60","U46","U30","U32","A42","A43","A43","A42","U59","U63","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_MR416i-a_Gen10P_52.36.3-6584_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.36.3-6584"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR416i-a_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"d82f0b1c0d0ff09604de03c648599810e3e833b2","SHA256Sum":"65343e88e1679b2d6e77123e41d9c841ba4fa098391ef56853e35ff836eee02b","SHA512Sum":"4e4d80e533d0754009d2efaf1afb92c70d949321bb7f71291402f6ea780efb6c7cc47d4443d1821bcb2562780116812c2066a00ea566284fcf6183e29beb2e16"}],"ComponentSizeInKB":7341,"CompsigList":[],"FileList":["HPE_MR416i-a_Gen10P_52.36.3-6584_A.HPb","HPE_MR416i-a_Gen10P_52.36.3-6584_A.xml","payload.json"],"Name":"HPE_MR416i-a_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"d82f0b1c0d0ff09604de03c648599810e3e833b2","SHA256Sum":"65343e88e1679b2d6e77123e41d9c841ba4fa098391ef56853e35ff836eee02b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.36.3-6584"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67690d6d946c40fa82f4658bcf","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068659.exe","SHA1Sum":"af6ea578929b6ee878c66beca85c3a65bba7cca4","SHA256Sum":"dac205138011be8e9ea207df82eee79d86ed2d02409c0c4ecd17016ae470a7a0","SHA512Sum":"cb355d0b58a75244daaf6c37688266f0efa4abe7a18ec009354b32dba3e3bddf020d1b9837ac0c8ff27181c73c13081c61b77779085eb1f3aef3ef1d51a25311"}],"ComponentSizeInKB":4230,"CompsigList":["cp068659.compsig"],"FileList":["cp068659.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"Name":"cp068659.exe","SHA1Sum":"af6ea578929b6ee878c66beca85c3a65bba7cca4","SHA256Sum":"dac205138011be8e9ea207df82eee79d86ed2d02409c0c4ecd17016ae470a7a0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d67acb393844eddb9adb9967c","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070602.exe","SHA1Sum":"d3c7229bc8bf483e35aee681d82cb70348e557d3","SHA256Sum":"4cdf252226f0ee766177bc04a4b5afb0fe88f2db867c48fb8cb39dccec23d262","SHA512Sum":"e70128717ab54bf5cb1518d8277c25628add0991b60c249d770f95871cdd514f04188b45ef1df3d77cb4782e23aeb93fd5575c2fe70c188ed5c0989e17886044"}],"ComponentSizeInKB":1718,"CompsigList":["cp070602.compsig"],"FileList":["cp070602.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp070602.exe","SHA1Sum":"d3c7229bc8bf483e35aee681d82cb70348e557d3","SHA256Sum":"4cdf252226f0ee766177bc04a4b5afb0fe88f2db867c48fb8cb39dccec23d262","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3cb0e260312a4259a3a98374a1","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB3T8HMLA-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDB7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDB7602Q"}]},"Files":[{"Checksum":[{"Filename":"cp070453.exe","SHA1Sum":"8746188910fb9f6c072e78b968ab90ebb2129a67","SHA256Sum":"6a619af1a8daec6baaa2472933927144869178c307f5ed542d444acad328e1d8","SHA512Sum":"218ef96f026b1b5d9a68f465c9a034d84122567b6168ddf1618ac0eaaef839c388d8553841c75b0e4831303eaf8f787ebf8c987a6bad9ea7adfab53c3d5bc464"}],"ComponentSizeInKB":7022,"CompsigList":["cp070453.compsig"],"FileList":["cp070453.xml","cpqsetup.exe","EDB7602Q.bin","ilorest_chif.dll","payload.json"],"Name":"cp070453.exe","SHA1Sum":"8746188910fb9f6c072e78b968ab90ebb2129a67","SHA256Sum":"6a619af1a8daec6baaa2472933927144869178c307f5ed542d444acad328e1d8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDB7602Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB3T8HMLA-00007 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MZ1LB3T8HMLA-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aa09ce6818eb43509673c73cdf","SupportedDevices":["4d2340a5-315a-424c-3354-384894df255d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"cp068658.exe","SHA1Sum":"2874b0150038b077f4e6a38e04b2dc5b5a18e005","SHA256Sum":"cac170f20d7b045e706ed24e1659f1788be4930024d44725449a246d8529ba86","SHA512Sum":"6c5f37784e184003a1e55cee4bf01d9a9fd1931a95b717e61c854f931b74a8c73c1b6fe7f9aca042ab0e410b81bd0506b4a87f9f704a96fc1ee69441f56c1032"}],"ComponentSizeInKB":4179,"CompsigList":["cp068658.compsig"],"FileList":["cp068658.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"Name":"cp068658.exe","SHA1Sum":"2874b0150038b077f4e6a38e04b2dc5b5a18e005","SHA256Sum":"cac170f20d7b045e706ed24e1659f1788be4930024d44725449a246d8529ba86","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0055eb2e6f1a4b82856baa2214","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071378.exe","SHA1Sum":"46261c8d39c6342850b21d66ba269309538bdaae","SHA256Sum":"542a56939cc9e3d15cdc6f38df8da943b7059693e8a432102adc1a9fe2527593","SHA512Sum":"32ebb7c30784de68e092bce0f9feaa3f563dc7c9089515662289d120f10d638bb24c83a8bbb4b5ff5a0613dc7052172e0bb050df6a658e6bbaf1b86b598a6017"}],"ComponentSizeInKB":1101,"CompsigList":["cp071378.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.man","bnxtnd.sys","cp071378.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071378.exe","SHA1Sum":"46261c8d39c6342850b21d66ba269309538bdaae","SHA256Sum":"542a56939cc9e3d15cdc6f38df8da943b7059693e8a432102adc1a9fe2527593","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"237.1.124.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2993c2a9730c4c5db79a42058e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U37","U38","U38","O43","U26","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072163.exe","SHA1Sum":"ccfefca604cc0292aa993cd44d805efea150feec","SHA256Sum":"b82f0d23053850f41bea49b229463dd399add45c173970daa1147d2e1cdb57f5","SHA512Sum":"0c2d22cf804b60b99451ab37e2796728a9567fb18b1106feb83edf0f9807d367b3ec479491ccf27c468a46df6e267eb5dc57e969bca72b43c2b312999006c652"}],"ComponentSizeInKB":3306,"CompsigList":["cp072163.compsig"],"FileList":["cp072163.xml","cpqsetup.exe","M52008TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072163.exe","SHA1Sum":"ccfefca604cc0292aa993cd44d805efea150feec","SHA256Sum":"b82f0d23053850f41bea49b229463dd399add45c173970daa1147d2e1cdb57f5","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_638ff21e174945ac903ef45f09","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"CP070925.zip","SHA1Sum":"7da08468ac0b000e3c73db3b4b29c28325a66a5f","SHA256Sum":"87534bafa2c1063677e4dcc049e6528ea4b1949d156864ccd1c526039ddfe84e","SHA512Sum":"161a60b53131f3d021310afa661f6ce5d67c2d51a622eafe3e54141efe1ed0f77f36666ae09816382225e57fd217ae958d2308fdcf4c5cce57037b0dc3cab655"}],"ComponentSizeInKB":19940,"CompsigList":["CP070925.compsig"],"FileList":["/CP070925_BUILD_5.data","/CP070925.vmexe64","/CP070925.vmfile","/CP070925_VMw.zip","/CP070925.xml","/payload.json","/CP070925_VMw.zip/index.xml","/CP070925_VMw.zip/vendor-index.xml","/CP070925_VMw.zip/metadata.zip","/CP070925_VMw.zip/vib20/CP070925/HPE_bootbank_CP070925_GPK8.5-8.0.0.20613240.vib","/CP070925_VMw.zip/metadata.zip/vendor-index.xml","/CP070925_VMw.zip/metadata.zip/vmware.xml","/CP070925_VMw.zip/metadata.zip/vibs/CP070925-6561887990288194908.xml","/CP070925_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070925_GPK8.5-8.0.0.20613240.xml"],"Name":"CP070925.zip","SHA1Sum":"7da08468ac0b000e3c73db3b4b29c28325a66a5f","SHA256Sum":"87534bafa2c1063677e4dcc049e6528ea4b1949d156864ccd1c526039ddfe84e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP070925","Version":"GPK8.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e34678c4a67f460192b88fd336","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069550.exe","SHA1Sum":"992fe0d542e99ec44af8166c0d379c7c7e39cf93","SHA256Sum":"4acd8f6e53a5866b135665830f22c7e1e9387aef8458a577d7f6d79ce4114643","SHA512Sum":"d23f754d7aed622fa920bc6269bbde2ba0828074a2dc6a96841c91eafd27978d15591d740c8c609a18332f95b62fa4be32455801b97389bc02510a6a1630a593"}],"ComponentSizeInKB":1015,"CompsigList":["cp069550.compsig"],"FileList":["cp069550.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069550.exe","SHA1Sum":"992fe0d542e99ec44af8166c0d379c7c7e39cf93","SHA256Sum":"4acd8f6e53a5866b135665830f22c7e1e9387aef8458a577d7f6d79ce4114643","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_139342fddb704f7abff074902a","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"41122c6a92f7f0200ec1c09b91995bfc5e213a02","SHA256Sum":"5b789986d90cd0dd4bd93d6c12baa940fef3bc4a2d5b1eecab7dd8ed635ba2b8","SHA512Sum":"af9e8002f6216427efc01a7b24e2d0f8a234ac2270ad1d66d146577ec45d9e375e5b8a95b315b015ce0a4445f563d7ce5749b66ccf288651b84213977460dfd2"}],"ComponentSizeInKB":829,"CompsigList":["elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"41122c6a92f7f0200ec1c09b91995bfc5e213a02","SHA256Sum":"5b789986d90cd0dd4bd93d6c12baa940fef3bc4a2d5b1eecab7dd8ed635ba2b8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_30b83a3f141d44b6818dcdc4fc","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for MicroServerv2 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"7fc963a27abbd8eba6bf6cb9eb57acb085964666","SHA256Sum":"a27a28c7a3bd3e5164c36ee0c0d5579fe58568f6344df3501274f34e69c43306","SHA512Sum":"97ae7f24cc433f4cf17c146d7123160863d9e045da93efbb789da47b71a086842c285d41c7c211c2ba598729b9568e39207361f61bc53c8293a4150cb9189f2c"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"7fc963a27abbd8eba6bf6cb9eb57acb085964666","SHA256Sum":"a27a28c7a3bd3e5164c36ee0c0d5579fe58568f6344df3501274f34e69c43306","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6dc28615340a479fa280db1614","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U61_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U61_2.64_04_01_2026.fwpkg","SHA1Sum":"6f38a06a71e0dc16c10a8705fcdd732ca607552b","SHA256Sum":"a938f0dd16a4af2d3b85f85d70e59b1cd3a880e0a9c7f944e9e80bf6d22df3ff","SHA512Sum":"4a6740509a6825510dedc2abcc4cf4f6b7c966cb1026931eec6e9994a1e541cdb5c246ceaba0691871853b21b591d9de5ae64de0a4c50ab6d68152e4d4e7f293"}],"ComponentSizeInKB":16422,"CompsigList":[],"FileList":["payload.json","U61_2.64_04_01_2026.signed.flash","U61_2.64_04_01_2026.xml"],"Name":"U61_2.64_04_01_2026.fwpkg","SHA1Sum":"6f38a06a71e0dc16c10a8705fcdd732ca607552b","SHA256Sum":"a938f0dd16a4af2d3b85f85d70e59b1cd3a880e0a9c7f944e9e80bf6d22df3ff","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_52947ecea68647d0a260823be7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067949.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Files":[{"Checksum":[{"Filename":"firmware-spsgen10-04.01.05.201-1.1.x86_64.rpm","SHA1Sum":"094933687b39304900d9722d5945edbac24bd421","SHA256Sum":"84bff5ff25574ab560e86045e167da0d2136ba891b7d12afcbe08c907884d9d0","SHA512Sum":"eb8a7492406eb25219eeb4f2a690358b58afd646bbf9ab5c18556ad1c65f7943b3a11b2f87d774ac8732a41f90fc78ce67e6359e5e2ad06c56ef52c900f1c6a9"}],"ComponentSizeInKB":3266,"CompsigList":["firmware-spsgen10-04.01.05.201-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/CP067951.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/cp067949.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/cp067949.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.201-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067951.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067951.scexe"],"Name":"firmware-spsgen10-04.01.05.201-1.1.x86_64.rpm","SHA1Sum":"094933687b39304900d9722d5945edbac24bd421","SHA256Sum":"84bff5ff25574ab560e86045e167da0d2136ba891b7d12afcbe08c907884d9d0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b543bb6e4f5c49269fa3893312","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.deb","SHA1Sum":"0680317ae8bd200dcd1b569e6c5285bd040495ee","SHA256Sum":"a3b05c193d9beb36d169677f60831cf3aa36a7c6533fcd4900cdf2d44205e32f","SHA512Sum":"2f508c268741753f7cd13656dd708465f9c401c57f51da1145db6477219e2712c8df988201833b1d79f616327582c50a31b2d999d58a39d3b243d9cb8f0e329f"}],"ComponentSizeInKB":4515,"CompsigList":["firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/CP071784.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071784.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071784.scexe"],"Name":"firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.deb","SHA1Sum":"0680317ae8bd200dcd1b569e6c5285bd040495ee","SHA256Sum":"a3b05c193d9beb36d169677f60831cf3aa36a7c6533fcd4900cdf2d44205e32f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b1777d993b140908654ed4a59","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3231-3030-304a575a4842"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"},{"DelayAfterInstallSec":180,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"CP072202.zip","SHA1Sum":"1e30cfbb7ed29b7a43538bffb51344eb3f323d70","SHA256Sum":"5121e652c263afef92ff303bf3f9550d55230d704787763b7d7f61db43f2c587","SHA512Sum":"17040a1d74ebfc890934e370900629acdf9df0a39c28f71b4106bf7cb5985f06b8ac717283c37fba6a6ef034f1a1f7baffc2a8cb0fc3ee7e62f6a20c16de0e11"}],"ComponentSizeInKB":27844,"CompsigList":["CP072202.compsig"],"FileList":["/CP072202_BUILD_1.data","/CP072202.vmcfg","/CP072202.vmexe64","/CP072202.vmfile","/CP072202_VMw.zip","/CP072202.xml","/payload.json","/CP072202_VMw.zip/index.xml","/CP072202_VMw.zip/vendor-index.xml","/CP072202_VMw.zip/metadata.zip","/CP072202_VMw.zip/vib20/CP072202/HPE_bootbank_CP072202_0130.1-8.0.0.20613240.vib","/CP072202_VMw.zip/metadata.zip/vendor-index.xml","/CP072202_VMw.zip/metadata.zip/vmware.xml","/CP072202_VMw.zip/metadata.zip/vibs/CP072202-3501987899116073482.xml","/CP072202_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072202_0130.1-8.0.0.20613240.xml"],"Name":"CP072202.zip","SHA1Sum":"1e30cfbb7ed29b7a43538bffb51344eb3f323d70","SHA256Sum":"5121e652c263afef92ff303bf3f9550d55230d704787763b7d7f61db43f2c587","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130","VibList":[{"Name":"CP072202","Version":"0130.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c3e4a5f95f245e992ca37eb50","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U37_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u37-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"4bcd351e7a2554a7f61ab3022952484dddbc406d","SHA256Sum":"fbd239cc6d510bd6e783e32c8ca1c5a729938bf81742941e8726c524b15f97d2","SHA512Sum":"7f02f606ff6990a70cbe152f4f7c498dab25b7c167c3a5f8e92d40a55e844a8e611456ab96170f29ec4b47cc1d331484c780d5eacdcaad6fd9e057cc36dc80a1"}],"ComponentSizeInKB":11431,"CompsigList":["firmware-system-u37-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/CP071407.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/U37_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071407.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071407.scexe"],"Name":"firmware-system-u37-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"4bcd351e7a2554a7f61ab3022952484dddbc406d","SHA256Sum":"fbd239cc6d510bd6e783e32c8ca1c5a729938bf81742941e8726c524b15f97d2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_379ff9b4322d4d04b38a9ec38d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"1c4f4c8f2ebac9fa591fd6fc3c5bff7e6f36a211","SHA256Sum":"80fa9600c579f2ea58014aae1b7ff676a2b694bae184c0fb260e34a1505ab17b","SHA512Sum":"51194821d71241e3768688d08825e676b29746f517bad50ea013881806eed475f6d34e7477dace656ae1a3c36833c098b365d4069138474cba29b7dc9d0ebc42"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"1c4f4c8f2ebac9fa591fd6fc3c5bff7e6f36a211","SHA256Sum":"80fa9600c579f2ea58014aae1b7ff676a2b694bae184c0fb260e34a1505ab17b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900347"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3f15f1eccb2e40be946ded02ab","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900347"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068737.exe","SHA1Sum":"ff9b3c91bffeea49c49a11857818809d16c7fa82","SHA256Sum":"bbef212dd316bbbfbec78b4e3050578a11ed5c572df48e9b950684c040875edb","SHA512Sum":"3ae34bf70e7fc2c2b64fba58f53fcaab3c2987289c3db5a592b1f63d6e43251b8213792a97101cb91be83b21e0731b830c652bfd2642aa68225a397934bd0a30"}],"ComponentSizeInKB":3945,"CompsigList":["cp068737.compsig"],"FileList":["cp068737.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPTG3.rel"],"Name":"cp068737.exe","SHA1Sum":"ff9b3c91bffeea49c49a11857818809d16c7fa82","SHA256Sum":"bbef212dd316bbbfbec78b4e3050578a11ed5c572df48e9b950684c040875edb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd123e76da4e4e189a0aa46bfb","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067924.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"firmware-dl20ml30gen10sps-05.01.05.103-2.1.x86_64.rpm","SHA1Sum":"b851b5934bb34e86357ea15659333b5899615bb3","SHA256Sum":"3e95a6073fa23d452511f89ab6b9d1cc9b75f37f7f04d3fe4c27ecfd4a0b5436","SHA512Sum":"f4702b2bda2dd9ac53b6c05d5eb4bcbc9edeeb5eafd18d8db3f6d36719bb5156c13d32e6c71246104e83572a427cec7a1a00d498a3943d3aeec92bbeb1b33e96"}],"ComponentSizeInKB":2135,"CompsigList":["firmware-dl20ml30gen10sps-05.01.05.103-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/CP068492.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/cp067924.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/cp067924.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.103-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068492.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068492.scexe"],"Name":"firmware-dl20ml30gen10sps-05.01.05.103-2.1.x86_64.rpm","SHA1Sum":"b851b5934bb34e86357ea15659333b5899615bb3","SHA256Sum":"3e95a6073fa23d452511f89ab6b9d1cc9b75f37f7f04d3fe4c27ecfd4a0b5436","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4b840130fd674097a45e2ff3ef","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U44","U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U33_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u33-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"b7b539ab9d837f7294802b5e1a73cc8dc092ab3a","SHA256Sum":"6da83f69baeb2e9dcacb87cbbef8b7fa8e401a0d71f07e60926aaa194ecc5668","SHA512Sum":"de227f49d0af512718c4d71662b879651cc9919980c09fedceb011779ffb3c30a490445bb7eae049ce2db3db3054d168781d162ed02de005f806c7910de7744b"}],"ComponentSizeInKB":11320,"CompsigList":["firmware-system-u33-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/CP071392.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/U33_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071392.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071392.scexe"],"Name":"firmware-system-u33-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"b7b539ab9d837f7294802b5e1a73cc8dc092ab3a","SHA256Sum":"6da83f69baeb2e9dcacb87cbbef8b7fa8e401a0d71f07e60926aaa194ecc5668","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d0ac9c7954946cda5b6ead69d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-tg3-3.139y-1.rhel9u7.x86_64.rpm","SHA1Sum":"04708b412f20e4b5590f2f96acdbed718a643219","SHA256Sum":"444818ee0a112cc7c8cd4f970614c4d2c7f26460849e031602f5138271067524","SHA512Sum":"85360e01a80b7cd816e2fc27e9e293d446ad9dc1dbcfc53d36bac3fc9fcd5cab01e153466ea00783782c3e8c8af46ecb62ab2d8996d03987714b7a06f5d0ada2"}],"ComponentSizeInKB":155,"CompsigList":["kmod-tg3-3.139y-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/883d47708b3a5b5445aadb18584d0b962cbc1c","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.139y-1.rhel9u7.x86_64.rpm","SHA1Sum":"04708b412f20e4b5590f2f96acdbed718a643219","SHA256Sum":"444818ee0a112cc7c8cd4f970614c4d2c7f26460849e031602f5138271067524","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139y-1"},{"Checksum":[{"Filename":"kmod-tg3-3.139y-1.rhel9u6.x86_64.rpm","SHA1Sum":"59ba84cb106c684f3d4b4ec63ad85dee1812402c","SHA256Sum":"13c047efa3dc8c8da05dd8db3e407ed5d6e245ca2da10833ec65df5278f5a3d4","SHA512Sum":"e1936e47c89aed5d535ebf73c7422d5ab7bf68d38d4df169992f0f1d6bfb696ae1079c9a8bf4aae15dfb7e7804ea3e7a09b9dc1d9af72b8ac057faa7b6f41864"}],"ComponentSizeInKB":154,"CompsigList":["kmod-tg3-3.139y-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/tg3","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/6e","./usr/lib/.build-id/6e/62398badfa5c9b79822054e5488b9377a5d7fa","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.139y-1.rhel9u6.x86_64.rpm","SHA1Sum":"59ba84cb106c684f3d4b4ec63ad85dee1812402c","SHA256Sum":"13c047efa3dc8c8da05dd8db3e407ed5d6e245ca2da10833ec65df5278f5a3d4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139y-1"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_af4ba00d5cda43d1a02dab444b","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","U68","U72","U70","A66","A66","03030202","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.deb","SHA1Sum":"93232cf52e44be40da77f3f026b33396c33844d7","SHA256Sum":"fc596b930743a87bc6d14747d30cb6b237b804cc0bb54d77dca078f55289ba6b","SHA512Sum":"f3ca777491d9893b6d6c95036ef2ae06e6a5fe9ea8711d87032a8debb66c568cfb1303612f69d2e7b2f8cd772c35573a2c29f462f719042097b70a5f845b1936"}],"ComponentSizeInKB":4378,"CompsigList":["firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/CP071778.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071778.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071778.scexe"],"Name":"firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.deb","SHA1Sum":"93232cf52e44be40da77f3f026b33396c33844d7","SHA256Sum":"fc596b930743a87bc6d14747d30cb6b237b804cc0bb54d77dca078f55289ba6b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20df8a847667467e8c856ba335","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp6-1.x86_64.rpm","SHA1Sum":"e10221d4a344489b145babcea8239bfb690d8f64","SHA256Sum":"6db2b4c782acaafe3a3d5055a88c4c5c68750f2fef5d1bfc1ac051613401c5e7","SHA512Sum":"17910f1cdb9e9564f1146b686c9501db128dfa69805e1493689f35a149955e381618b6a64fb7d454b065932229379a0bd8efdc728bd6af068aaaf6e1cca6dc65"}],"ComponentSizeInKB":934,"CompsigList":["lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp6-1.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/3e","./usr/lib/.build-id/3e/2731b76ac14e53415cfea000d2e1f6abae4b3d","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp6-1.x86_64.rpm","SHA1Sum":"e10221d4a344489b145babcea8239bfb690d8f64","SHA256Sum":"6db2b4c782acaafe3a3d5055a88c4c5c68750f2fef5d1bfc1ac051613401c5e7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.736.04.00"},{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp7-1.x86_64.rpm","SHA1Sum":"d8aa6a570efceeda9bb420b76e5edbff52891499","SHA256Sum":"a0e259f6ce9dc50ad05ea7e4214372b6977866f6d54698c6e26fb31b5539e890","SHA512Sum":"68238a3e61d7eb92712d967012c5332fa752e2bd0eaf1c5dc8ceef3e397c5bcb1e92dc2c3fa56365a427be0eeb98cfb3271fd44b8df275952277327ddfe25be4"}],"ComponentSizeInKB":917,"CompsigList":["lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp7-1.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/51","./usr/lib/.build-id/51/294f19f2bf987517e078283fc04653ca667eae","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.736.04.00_sles15sp7-1.x86_64.rpm","SHA1Sum":"d8aa6a570efceeda9bb420b76e5edbff52891499","SHA256Sum":"a0e259f6ce9dc50ad05ea7e4214372b6977866f6d54698c6e26fb31b5539e890","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.736.04.00"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3ba4eb4cd4b46b0a4a17b1b94","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U58","U54","U58","U63","U54","U54","U61","U60","U46","U30","U32","A42","A43","A43","A42","U59","U63","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp068665.exe","SHA1Sum":"d3be0c01e65dc927094aa1636f10a305bf2955c3","SHA256Sum":"a1f701b315e51a52dc98ac6a12896b580329ed4fc5d6e430b5533ccc9d12e63a","SHA512Sum":"d1f6fb61f86ec998c7a457799defa1ee0d3bae29110ea1d6b5c4a884804e3c4ff37d32d1acd8f425e7a1e85c73b33ffd4f97365fbf1961abab11f983bb2acf96"}],"ComponentSizeInKB":3817,"CompsigList":["cp068665.compsig"],"FileList":["cp068665.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNTG6.rel","setup.dll"],"Name":"cp068665.exe","SHA1Sum":"d3be0c01e65dc927094aa1636f10a305bf2955c3","SHA256Sum":"a1f701b315e51a52dc98ac6a12896b580329ed4fc5d6e430b5533ccc9d12e63a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dd4d0089d26745a78f0c891836","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.rpm","SHA1Sum":"55be3bf6c2f08c20bd6cff25e90bb3a8acbe32cd","SHA256Sum":"e3e758462525856a308ae9df7ea7b503c72939df5b01e1759858155748838731","SHA512Sum":"e23b05cd0da72f92cf74c69332f5f6a8163d116a87b7d9df681094141c88bc49a2bcba64bf463ac31fd99ed1d90433ce1188ca191a64e7a54232b2b489520bc2"}],"ComponentSizeInKB":2345,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.rpm","SHA1Sum":"55be3bf6c2f08c20bd6cff25e90bb3a8acbe32cd","SHA256Sum":"e3e758462525856a308ae9df7ea7b503c72939df5b01e1759858155748838731","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.rpm","SHA1Sum":"ecc2d7bc65e882dac4a59efb0a7b32f129e8f555","SHA256Sum":"750c78428e04f63eeef6ded88059b9a0c6048bcc9b384157fea4c262c56e7cb3","SHA512Sum":"0b10b10c1d4cd67e888df86db631558e3c3963b2fa7ab7c23ac28650249d3a7aeaf18758567bac6c5fc916df369ffdc80e7606eab58d705e0b0ad92373249c62"}],"ComponentSizeInKB":2707,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/compat","./usr/lib/modules/6.12.0-160000.5-default/updates/compat/mlx_compat.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd/rnbd-client.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd/rnbd-server.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/fwctl.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_ucm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_umad.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_uverbs.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/iw_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/rdma_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/rdma_ucm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/cxgb4","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/efa","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/efa/efa.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/hfi1","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/irdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mana","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx4","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mthca","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/ocrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qedr","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qib","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/usnic","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/vmw_pvrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rdmavt","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rxe","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/siw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/siw/siw.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/ipoib","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/iser","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/isert","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/opa_vnic","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srp","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srpt","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxfw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxsw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/host","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/host/nvme-rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/target","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/target/nvmet-rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net","./usr/lib/modules/6.12.0-160000.5-default/updates/net/9p","./usr/lib/modules/6.12.0-160000.5-default/updates/net/9p/9pnet_rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/mlxdevm","./usr/lib/modules/6.12.0-160000.5-default/updates/net/mlxdevm/mlxdevm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/rds","./usr/lib/modules/6.12.0-160000.5-default/updates/net/rds/rds_rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc/smc.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc/smc_diag.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.rpm","SHA1Sum":"ecc2d7bc65e882dac4a59efb0a7b32f129e8f555","SHA256Sum":"750c78428e04f63eeef6ded88059b9a0c6048bcc9b384157fea4c262c56e7cb3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 16 SP0(AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_01d2bfaaf7ff40f0a8341275e8","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070957.zip","SHA1Sum":"fde7e82f1ab91c07778c3e3d49bf37429692f965","SHA256Sum":"394f34f40ed11e75037359ce898a935ec053d5694b60927496959dd2654519b4","SHA512Sum":"0136319a521791e2ee01d41ab6801aa7e2f470cf8c2a700d4bc3923a5b4f3830155574895a3c2caee6278c0d8fa78b9153c785fbeb4cb8ded613ede45621e62d"}],"ComponentSizeInKB":17698,"CompsigList":["CP070957.compsig"],"FileList":["/CP070957_BUILD_7.data","/CP070957.vmexe64","/CP070957.vmfile","/CP070957_VMw.zip","/CP070957.xml","/payload.json","/CP070957_VMw.zip/index.xml","/CP070957_VMw.zip/vendor-index.xml","/CP070957_VMw.zip/metadata.zip","/CP070957_VMw.zip/vib20/CP070957/HPE_bootbank_CP070957_HPG6.7-8.0.0.20613240.vib","/CP070957_VMw.zip/metadata.zip/vendor-index.xml","/CP070957_VMw.zip/metadata.zip/vmware.xml","/CP070957_VMw.zip/metadata.zip/vibs/CP070957--1247269693036596716.xml","/CP070957_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070957_HPG6.7-8.0.0.20613240.xml"],"Name":"CP070957.zip","SHA1Sum":"fde7e82f1ab91c07778c3e3d49bf37429692f965","SHA256Sum":"394f34f40ed11e75037359ce898a935ec053d5694b60927496959dd2654519b4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070957","Version":"HPG6.7-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e6345b224b6f4bc3acfd2be67b","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"3711213d443c4cd98523798db5171436f49dd3fa","SHA256Sum":"263f27cb29984f96456bd720ba6115967cb5fb03d3828e18251b17ed6e9a34f6","SHA512Sum":"edc299a26c3bd061411282479688cb2a2391c25547886134fc3ae19338cf6805fcc4e89e64c8e21ce01f5ec377c8a276d2ace4aa886567a27d20a45fea0836e0"}],"ComponentSizeInKB":17516,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.3.0_k6.12.0_160000.5-2.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./usr/lib/firmware/qed","./usr/lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qed.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qede.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedf.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedi.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.3.0_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"3711213d443c4cd98523798db5171436f49dd3fa","SHA256Sum":"263f27cb29984f96456bd720ba6115967cb5fb03d3828e18251b17ed6e9a34f6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.3.0-2"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03402e8b2ca6476c91b90ad459","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070554.exe","SHA1Sum":"30141ebdbfbcecf7bc32d6fad6300af145aa5118","SHA256Sum":"b3c59aab8900c246acbdd1f0696a0625dca0e34dca7e93255a556e029108ffe8","SHA512Sum":"58e66e9bf135c86da9e189b8fbd853a72a0e227047b780a4165baa339d34a40cfb0f5de19d05311c96cb842a9b4c75b95e71b1f2981db5df5f4d18e3e0f828be"}],"ComponentSizeInKB":1687,"CompsigList":["cp070554.compsig"],"FileList":["cp070554.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"Name":"cp070554.exe","SHA1Sum":"30141ebdbfbcecf7bc32d6fad6300af145aa5118","SHA256Sum":"b3c59aab8900c246acbdd1f0696a0625dca0e34dca7e93255a556e029108ffe8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.20.43.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6aec0619ce4e437692d7574f73","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-befd42bd64_0HPG3-2.1_amd64.deb","SHA1Sum":"c627aae360a53ddf622e38a26585991cc4e826b0","SHA256Sum":"1cc9e37ae9a4d9d931ad167bd169f2a8744aa230ba1c4b233c583d5dd934b197","SHA512Sum":"1bb91b3b236493f7bf667c3d06f7eaad269c60fb5827aafe4579f8f669cd5b0543c796282bb52b2d978c5f729d45e6229d6d6334d6efc10bb04e02e5da99f82e"}],"ComponentSizeInKB":7486,"CompsigList":["firmware-hdd-befd42bd64_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/CP071811.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071811.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071811.scexe"],"Name":"firmware-hdd-befd42bd64_0HPG3-2.1_amd64.deb","SHA1Sum":"c627aae360a53ddf622e38a26585991cc4e826b0","SHA256Sum":"1cc9e37ae9a4d9d931ad167bd169f2a8744aa230ba1c4b233c583d5dd934b197","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_326bafcd936d4f7aaf50e7de12","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","SHA1Sum":"667073d8caeb03a11e92bcfa3902861b96a70bbd","SHA256Sum":"55113065e28e63c620ccf59b18253b23a39944acb7538de114d674b8b8619792","SHA512Sum":"2ff132e32ac2b3cdcbc8924f231744381c97185530137b25741190b798e52087a5a834a42365659e4b55de0bc7b591cc7f0f270bde6951c764052817f8dbefce"}],"ComponentSizeInKB":5478,"CompsigList":["firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/CP068922.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068922.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068922.scexe"],"Name":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","SHA1Sum":"667073d8caeb03a11e92bcfa3902861b96a70bbd","SHA256Sum":"55113065e28e63c620ccf59b18253b23a39944acb7538de114d674b8b8619792","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d983b2865074432aa1669f5c01","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069521.exe","SHA1Sum":"0173147547c8c3cbd37a36d87cb27ca1315f72d7","SHA256Sum":"006c412c6ed4ed7a9bf431c360d2216600183725e376c1734a4213bb2717c108","SHA512Sum":"1161b0af14bd3abd1762bba145ecd770342e5e115fcc07d95678a20be3a72e59122067dadd79ba897103047d04f42daf9e06db09b6825ff8a04ab654b82e5006"}],"ComponentSizeInKB":1054,"CompsigList":["cp069521.compsig"],"FileList":["cp069521.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069521.exe","SHA1Sum":"0173147547c8c3cbd37a36d87cb27ca1315f72d7","SHA256Sum":"006c412c6ed4ed7a9bf431c360d2216600183725e376c1734a4213bb2717c108","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f339b773d97449db8bc0d1ac2b","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","H08","H08","H10","H10","H10","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","SHA1Sum":"90068aa562bf394f76ab6fa8ec346bb0e3a326c0","SHA256Sum":"e384f4928f9eaebe951691a70ef7285fcd9eb472087f3e12b108311f188e5c7e","SHA512Sum":"a0b8b46c8d5d3b4736ba7552e98a103b920c25588b3318851f751bf35e0a00eb80ba9d5d11b18099739a09c02b97e23031619191f83bb6b9a9d2a39918928118"}],"ComponentSizeInKB":3202,"CompsigList":["firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw/hp_mbi_7.19.27.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064333.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064333.scexe"],"Name":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","SHA1Sum":"90068aa562bf394f76ab6fa8ec346bb0e3a326c0","SHA256Sum":"e384f4928f9eaebe951691a70ef7285fcd9eb472087f3e12b108311f188e5c7e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"2.37.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67291762a5054079aef09cf140","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957414N4140HC.fwpkg","SHA1Sum":"b705be94179670cc7679ce8281db003e00635af3","SHA256Sum":"3ebdaab3a570f56df204202cf9d01bb86b16f636f20ba4f8a73116985869a87f","SHA512Sum":"394bb23d5d25ab0b8f503dcc2526fa27282fa5fed25074de480c538c03a560611c4f2654da088ae674baaebf5cd9c6b02f0e5c3340b92c983be6a5c7cdb92a44"}],"ComponentSizeInKB":1364,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957414N4140HC.HPb","BCM237.1.148.0_BCM957414N4140HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957414N4140HC.fwpkg","SHA1Sum":"b705be94179670cc7679ce8281db003e00635af3","SHA256Sum":"3ebdaab3a570f56df204202cf9d01bb86b16f636f20ba4f8a73116985869a87f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57414 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_957414OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c6ce31215884a218ad40f7124","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070950.zip","SHA1Sum":"015e4851fe15993466337dfa592c9927c08030eb","SHA256Sum":"b3354bfedb23ecc1c19d694eba56af14a361d27442bb446d533118b9c505cc41","SHA512Sum":"b8722d9c45124adcabe0c155f657e1c29ec672e5b8f244e682b3139132006be06635901ee57892e68d6fb94b2023327959c96c453df88162e6abdf401c62857c"}],"ComponentSizeInKB":19087,"CompsigList":["CP070950.compsig"],"FileList":["/CP070950_BUILD_3.data","/CP070950.vmexe64","/CP070950.vmfile","/CP070950_VMw.zip","/CP070950.xml","/payload.json","/CP070950_VMw.zip/index.xml","/CP070950_VMw.zip/vendor-index.xml","/CP070950_VMw.zip/metadata.zip","/CP070950_VMw.zip/vib20/CP070950/HPE_bootbank_CP070950_HPG5.3-8.0.0.20613240.vib","/CP070950_VMw.zip/metadata.zip/vendor-index.xml","/CP070950_VMw.zip/metadata.zip/vmware.xml","/CP070950_VMw.zip/metadata.zip/vibs/CP070950-448983189163845683.xml","/CP070950_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070950_HPG5.3-8.0.0.20613240.xml"],"Name":"CP070950.zip","SHA1Sum":"015e4851fe15993466337dfa592c9927c08030eb","SHA256Sum":"b3354bfedb23ecc1c19d694eba56af14a361d27442bb446d533118b9c505cc41","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070950","Version":"HPG5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22b0dd4e54874319b044d14eda","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","SHA1Sum":"9ca0feb21f5b356d0325483f791f4b720651628e","SHA256Sum":"d74415ef6caf672dc69f1f7adab7e81e5d8be56ccf7ceb317f984582b8d1f871","SHA512Sum":"7b8fae301d646a3fcf71c0ad4caa14a76f24a9ca1c91f88498288844991d542148239599676e01a6ce80d0e2bc9935032e19c2386a651b7757e87f9a2973449a"}],"ComponentSizeInKB":6016,"CompsigList":["firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/CP068930.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068930.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068930.scexe"],"Name":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","SHA1Sum":"9ca0feb21f5b356d0325483f791f4b720651628e","SHA256Sum":"d74415ef6caf672dc69f1f7adab7e81e5d8be56ccf7ceb317f984582b8d1f871","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_550deb8b0471468da76947e52e","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070962.zip","SHA1Sum":"4a3c6e9eb8a0ff119b2d8f4e9c1c4947ca345253","SHA256Sum":"cd7eaa974a2310a2e0e686af5982358ebf1c2b5f270f7c864122425804fb5865","SHA512Sum":"bfe69fd88db28aaf198f4a3c31150cf65fac20a2738bdc31ad29ce418fd68159d4118eb1da8893ddf0d83a02084b43e5d17d8ddf508e91366214510e082634ba"}],"ComponentSizeInKB":21736,"CompsigList":["CP070962.compsig"],"FileList":["/CP070962_BUILD_1.data","/CP070962.vmexe64","/CP070962.vmfile","/CP070962_VMw.zip","/CP070962.xml","/payload.json","/CP070962_VMw.zip/index.xml","/CP070962_VMw.zip/vendor-index.xml","/CP070962_VMw.zip/metadata.zip","/CP070962_VMw.zip/vib20/CP070962/HPE_bootbank_CP070962_HPD4.1-8.0.0.20613240.vib","/CP070962_VMw.zip/metadata.zip/vendor-index.xml","/CP070962_VMw.zip/metadata.zip/vmware.xml","/CP070962_VMw.zip/metadata.zip/vibs/CP070962-7134521735386207040.xml","/CP070962_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070962_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070962.zip","SHA1Sum":"4a3c6e9eb8a0ff119b2d8f4e9c1c4947ca345253","SHA256Sum":"cd7eaa974a2310a2e0e686af5982358ebf1c2b5f270f7c864122425804fb5865","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070962","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_218411b58a6c4fb0a9950324bd","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"ACCE_2.1.0s.fwpkg","SHA1Sum":"60f735ffa7abfb8650dd7c3058ca206fadabeafa","SHA256Sum":"09e060c300724c349de464fb6d735f33c5dfe79fbfaabed2db9f20553fc22b36","SHA512Sum":"41006fe5d19628294dbd76126e61a2c778d915500927ac580d301ecd5a613a6faefee243199fbfacc25218caa3e85f614ea1ef8f447f8417342ba309b5ea91d7"}],"ComponentSizeInKB":533,"CompsigList":[],"FileList":["ACCE_2.1.0s.bin","ACCE_2.1.0s.xml","payload.json"],"Name":"ACCE_2.1.0s.fwpkg","SHA1Sum":"60f735ffa7abfb8650dd7c3058ca206fadabeafa","SHA256Sum":"09e060c300724c349de464fb6d735f33c5dfe79fbfaabed2db9f20553fc22b36","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"ROM Flash Universal Firmware Package - HPE Edgeline Chassis Controller Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0f83ba3170b24293893b7b45d0","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","H08","HPE Edgeline EL8000t Converged Edge System","H10","H11","H11"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070562.exe","SHA1Sum":"59f74c4a530a3954af3b2763beef477324ae40f3","SHA256Sum":"7e17f3fafa841e4e6322d53ad5da2fc1a5c7610c6a2b9915dae1ffc2d1403112","SHA512Sum":"07ccfd29e9d56d80225d15917c4e48a238545faa2d213a68cfdce181059cacd26e2b92086fd6e721c1a845010fe58bf1394fe239a560598ec6eea06def2aa64f"}],"ComponentSizeInKB":1388,"CompsigList":["cp070562.compsig"],"FileList":["cp070562.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"Name":"cp070562.exe","SHA1Sum":"59f74c4a530a3954af3b2763beef477324ae40f3","SHA256Sum":"7e17f3fafa841e4e6322d53ad5da2fc1a5c7610c6a2b9915dae1ffc2d1403112","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.18.162.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0dff3ce052a549f2aa7c4d1e12","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072360.exe","SHA1Sum":"15b4772a01ff6d9dfecfa3de400f30dfaf09eaf5","SHA256Sum":"37425bc92e97599670bc2b64c5dd98a948528da9488fa999bef581e016e8b704","SHA512Sum":"f6aa30516945a891ed19f84e5351235c4d42f17bd3a8fa6c0f511aa8d64efbf5890d797ba19b28341ff997de9a537bc1a9f51978d497c1c7dc8ac6f969bf7e26"}],"ComponentSizeInKB":26861,"CompsigList":["cp072360.compsig"],"FileList":["cp072360.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072360.exe","SHA1Sum":"15b4772a01ff6d9dfecfa3de400f30dfaf09eaf5","SHA256Sum":"37425bc92e97599670bc2b64c5dd98a948528da9488fa999bef581e016e8b704","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.0.25"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_479ac3db85f34b889bce665537","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.deb","SHA1Sum":"7540c03777763ae4ebd8708b518ffe3e6be1e3ee","SHA256Sum":"11c3f02eb36daf617da9245579130669c2d6db69707655d04d3968be45bd7ecb","SHA512Sum":"b508dff6f2e0664c4d844a05093a46cd97c01855c4fd83eb31ca3f36add5010ced43a203263346f5cd1a8fe8340f89c38848125e0bfd0d15caacb4f87d48c0e8"}],"ComponentSizeInKB":4221,"CompsigList":["firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/CP071782.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071782.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071782.scexe"],"Name":"firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.deb","SHA1Sum":"7540c03777763ae4ebd8708b518ffe3e6be1e3ee","SHA256Sum":"11c3f02eb36daf617da9245579130669c2d6db69707655d04d3968be45bd7ecb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f64ad823176400d8fac4ddddb","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U39_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u39-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"6e9fde4dc638ed6751a07d0d619d194a3e27cc83","SHA256Sum":"1d6b59755db593b65ae7e80d82ad8752465be68a529679e1f02683b796a865b4","SHA512Sum":"b5b2f41d70909b9e7ebd75e8608acdf9c41f058dfaec32f876033c39aa2924b5e38bb2e5ac103acb2e9ef35fd4132a220752428830a70eed06c95a64d902c3b8"}],"ComponentSizeInKB":11476,"CompsigList":["firmware-system-u39-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/CP071441.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/U39_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071441.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071441.scexe"],"Name":"firmware-system-u39-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"6e9fde4dc638ed6751a07d0d619d194a3e27cc83","SHA256Sum":"1d6b59755db593b65ae7e80d82ad8752465be68a529679e1f02683b796a865b4","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6fabde7808694899a3136ace7d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070916.zip","SHA1Sum":"c528f709ce2d97dd63711a60701ed121fb7543d0","SHA256Sum":"5d57507e4bd335bf2748e02246063ee13b21d0a2c91211e2ca7fcd96a0ee7802","SHA512Sum":"3acabbdad3171884103f1581ee27a9cb5b2b141505ea95bf0fa078da6b9502ac5d16d16d0ef3f3e2fa385cc732bb921b825df0786a36e9ff631a40981da80dbb"}],"ComponentSizeInKB":18029,"CompsigList":["CP070916.compsig"],"FileList":["/CP070916_BUILD_3.data","/CP070916.vmexe64","/CP070916.vmfile","/CP070916_VMw.zip","/CP070916.xml","/payload.json","/CP070916_VMw.zip/index.xml","/CP070916_VMw.zip/vendor-index.xml","/CP070916_VMw.zip/metadata.zip","/CP070916_VMw.zip/vib20/CP070916/HPE_bootbank_CP070916_HPD5.3-8.0.0.20613240.vib","/CP070916_VMw.zip/metadata.zip/vendor-index.xml","/CP070916_VMw.zip/metadata.zip/vmware.xml","/CP070916_VMw.zip/metadata.zip/vibs/CP070916-7105643938265783076.xml","/CP070916_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070916_HPD5.3-8.0.0.20613240.xml"],"Name":"CP070916.zip","SHA1Sum":"c528f709ce2d97dd63711a60701ed121fb7543d0","SHA256Sum":"5d57507e4bd335bf2748e02246063ee13b21d0a2c91211e2ca7fcd96a0ee7802","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070916","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3e19ea5a7209484d8acd365d65","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"22_49_1014-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.49.1014"}]},"Files":[{"Checksum":[{"Filename":"22_49_1014-MCX623105AS-VDA_Ax.pldm.fwpkg","SHA1Sum":"e6ff510b438315442d05e329025e4ce5446fe768","SHA256Sum":"5b29dc816a95ea62b7d1ba611ab171d55ed23d95b5ebd1d51245440ec6fe12f8","SHA512Sum":"e2649e8fa768b1bb0742634c7ab901835da751332623bdda2facf35f3b460745ea77593085abd7a4affd8519752184f37b70706cdc432d8e8c44026435e50e09"}],"ComponentSizeInKB":7717,"CompsigList":[],"FileList":["22_49_1014-MCX623105AS-VDA_Ax.pldm.signed","22_49_1014-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"Name":"22_49_1014-MCX623105AS-VDA_Ax.pldm.fwpkg","SHA1Sum":"e6ff510b438315442d05e329025e4ce5446fe768","SHA256Sum":"5b29dc816a95ea62b7d1ba611ab171d55ed23d95b5ebd1d51245440ec6fe12f8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"TypeOfChange":"1","Version":"22.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ca0d92b413c840778ce6748f61","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","A55","A55","A56","A56","U59","U58","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"cp068635.exe","SHA1Sum":"67c0aa3a220eb6be0a1c8147f0241eb7bd03bd71","SHA256Sum":"63890f44054a00c797e7601b60fb5d74bd72a4e5bdf90408ef3adad7ae14d8b8","SHA512Sum":"7639017b42b61b080fde0a05b5911adc5f5c114c2cd47fff0324a05a49cbac4a5b58e97201ead65484b76f329663f7bcc85eddb7519816684134a76a82d846ba"}],"ComponentSizeInKB":5676,"CompsigList":["cp068635.compsig"],"FileList":["85032G00_mp.bin","cp068635.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068635.exe","SHA1Sum":"67c0aa3a220eb6be0a1c8147f0241eb7bd03bd71","SHA256Sum":"63890f44054a00c797e7601b60fb5d74bd72a4e5bdf90408ef3adad7ae14d8b8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2209d7eaa57a4b1d8bc6228741","SupportedDevices":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","SHA1Sum":"4056985b475febfd2df1eb4cb7fbb571f9f25503","SHA256Sum":"05ade18957696c64389159ec24bcad642b6468fe5fb58c0cc1db68d77c6e69c4","SHA512Sum":"96d3d3a87a43b6ac98be6452f27532ddb8eb2984d6628700844843936bd4b5632f4893ccf1618b42fede98f319a3b364f48104cffb7d4ace94a515c0b7b4b8f8"}],"ComponentSizeInKB":6351,"CompsigList":["firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/CP068849.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068849.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068849.scexe"],"Name":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","SHA1Sum":"4056985b475febfd2df1eb4cb7fbb571f9f25503","SHA256Sum":"05ade18957696c64389159ec24bcad642b6468fe5fb58c0cc1db68d77c6e69c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07622a2605684dfc8bb07322b6","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070967.zip","SHA1Sum":"0329f1b3fef7bde5e2df94bc005647fc76938acd","SHA256Sum":"b6600d5f1631317ee343113a6a72f707ff4002d3989fe75188ebb3c3d5b0d1f6","SHA512Sum":"aa806c503bbfe0bd61956ed24e0f430df4824c69d35ac864bc947e3aa53f2a247496be7b69fa9a723186cf0cd142511fa20c2aab4d02929e5cfd4424176701fa"}],"ComponentSizeInKB":19931,"CompsigList":["CP070967.compsig"],"FileList":["/CP070967_BUILD_1.data","/CP070967.vmexe64","/CP070967.vmfile","/CP070967_VMw.zip","/CP070967.xml","/payload.json","/CP070967_VMw.zip/index.xml","/CP070967_VMw.zip/vendor-index.xml","/CP070967_VMw.zip/metadata.zip","/CP070967_VMw.zip/vib20/CP070967/HPE_bootbank_CP070967_HPD2.1-8.0.0.20613240.vib","/CP070967_VMw.zip/metadata.zip/vendor-index.xml","/CP070967_VMw.zip/metadata.zip/vmware.xml","/CP070967_VMw.zip/metadata.zip/vibs/CP070967-8451312429881359788.xml","/CP070967_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070967_HPD2.1-8.0.0.20613240.xml"],"Name":"CP070967.zip","SHA1Sum":"0329f1b3fef7bde5e2df94bc005647fc76938acd","SHA256Sum":"b6600d5f1631317ee343113a6a72f707ff4002d3989fe75188ebb3c3d5b0d1f6","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070967","Version":"HPD2.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4931dc725df24570be72531ec5","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000-5.04-18.1.x86_64.rpm","SHA1Sum":"1a789003460c57dea29adeb0b6ee1c602dcf1109","SHA256Sum":"6818468e920bd0056937fcb66be519a4802f4825d8d9f77c27daff69a649f18e","SHA512Sum":"fa190815851db15f9132f926420f43508642c850930043afd7f865f44cac8fb8bffa3fdba24b85f7dbd75a48706d2e5917c8533d9c0fc0349159497fe25e2877"}],"ComponentSizeInKB":3605,"CompsigList":["firmware-d3000-5.04-18.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/CP072210.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072210.scexe"],"Name":"firmware-d3000-5.04-18.1.x86_64.rpm","SHA1Sum":"1a789003460c57dea29adeb0b6ee1c602dcf1109","SHA256Sum":"6818468e920bd0056937fcb66be519a4802f4825d8d9f77c27daff69a649f18e","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ce30312f59f4c64a37da66b32","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070244.zip","SHA1Sum":"02810f7d4558e444cfe77ecb9bcddd00e4829eb2","SHA256Sum":"cc7b31b4a80bff290616bacc6c44e290eecad75e14dde296e40b38bf7aea126c","SHA512Sum":"3324802f3d91dc8b7aa426f5b7f0cf7002e21b797867aa8779aa199cecf5a7bee4bfe43cce1b6109edafa8d7cf38f8fc736171b758d3a8d3fbf6af65cf5a9a9b"}],"ComponentSizeInKB":211,"CompsigList":["cp070244.compsig"],"FileList":["/cp070244.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/vib20/ixgben/INT_bootbank_ixgben_1.23.3.0-1OEM.900.0.24755229.vib","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ixgben--8289692326410911223.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.xml"],"Name":"cp070244.zip","SHA1Sum":"02810f7d4558e444cfe77ecb9bcddd00e4829eb2","SHA256Sum":"cc7b31b4a80bff290616bacc6c44e290eecad75e14dde296e40b38bf7aea126c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"ixgben","Version":"1.23.3.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.23.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.23.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa5d6e746ec14924820d25c3c7","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A59","U77","A66","A66","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U32_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u32-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"0fc6ace1d918cdef3016bb4619027ab80fe9eb01","SHA256Sum":"e42c4ecda802a30192703be73e0db22333f4fe346663e46de056de99ec355558","SHA512Sum":"03cb3b25380b1a8b0bd9d7eb1eafcea786a546f81420c4d5d80034f2b9bc1b5f10b56f7742b78588ee32df408919b6e43d53217ec26da10b13b926b73de79aa4"}],"ComponentSizeInKB":11663,"CompsigList":["firmware-system-u32-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/CP071394.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/U32_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071394.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071394.scexe"],"Name":"firmware-system-u32-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"0fc6ace1d918cdef3016bb4619027ab80fe9eb01","SHA256Sum":"e42c4ecda802a30192703be73e0db22333f4fe346663e46de056de99ec355558","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9a5beb809e5c44259638a59f40","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","SHA1Sum":"4d01ce997d738d0108847e21fb1f1cccd6fd4646","SHA256Sum":"5521433ec50d0907e4ea8432111d8d87dc90aace20d3c11ea288a913432fc5e7","SHA512Sum":"3591874ec60eac1e0fcd3610145b7118fd367ec42b6de6072694d0633f2b8960831268df370442afc068c87b3b443331ffd3f777e25e93f804d790bc4520c7fe"}],"ComponentSizeInKB":5861,"CompsigList":["firmware-hdd-492a9952f6-HPG5-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/CP068907.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068907.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068907.scexe"],"Name":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","SHA1Sum":"4d01ce997d738d0108847e21fb1f1cccd6fd4646","SHA256Sum":"5521433ec50d0907e4ea8432111d8d87dc90aace20d3c11ea288a913432fc5e7","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a63b21feb2248f7a2d9ef0791","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","SHA1Sum":"5f2baa8ff9e52995caf21da4c0ed2c12485dffd4","SHA256Sum":"0a2bb6f2f4d83fccda450c12230402e3e4a4f53613c885bd10075a0ac293b970","SHA512Sum":"dc59376aacb7940d6835381d7be4c4e4e4721cc3be7acd8c030699f43b0652ec6a16a74708be460476b2d143fdd463839cb96da1b4fe0b5c9cab128825d35161"}],"ComponentSizeInKB":9299,"CompsigList":["firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/CP068908.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068908.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068908.scexe"],"Name":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","SHA1Sum":"5f2baa8ff9e52995caf21da4c0ed2c12485dffd4","SHA256Sum":"0a2bb6f2f4d83fccda450c12230402e3e4a4f53613c885bd10075a0ac293b970","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_426ba3dc2e0c4272b5336f0e13","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.deb","SHA1Sum":"9b687dca696b0233e3d1681c7ace71a18bf5af2b","SHA256Sum":"a348301f5bc40211e6bc5c3920c238afc05b99810331a373a489ae8f83c5550e","SHA512Sum":"ac90110b5586c19c91f3584ba5687574805e0621890026f04bf0dc83c5f685d8cf5e2dcd96b3461a11f277ec946c564a9852c5e0fe39aa2d14049eef074a8161"}],"ComponentSizeInKB":6751,"CompsigList":["firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/CP071749.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/MPK78H5Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071749.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071749.scexe"],"Name":"firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.deb","SHA1Sum":"9b687dca696b0233e3d1681c7ace71a18bf5af2b","SHA256Sum":"a348301f5bc40211e6bc5c3920c238afc05b99810331a373a489ae8f83c5550e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3 and MZXL57T6HALA-000H3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_38e0906f24c94ab59d7b8c2acf","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3830-3048d90154e8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068650.exe","SHA1Sum":"ba46621b84faaedee4245d5565d825d7b6e6d6f4","SHA256Sum":"f9d5f1710756a94fb07262d2f72699271b7cb6c170b7a34bf763c2f2195c4616","SHA512Sum":"2789275918626bffcc89f9ef150b2265566ac37e3fe244a1e3f260fe8677d0a856b79ec25b6b8357674cdb4c1d3290fb5076ab4214a7eb7f4104c42382c59eb3"}],"ComponentSizeInKB":3924,"CompsigList":["cp068650.compsig"],"FileList":["cp068650.xml","cpqsetup.exe","KAPM6ALSHPD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068650.exe","SHA1Sum":"ba46621b84faaedee4245d5565d825d7b6e6d6f4","SHA256Sum":"f9d5f1710756a94fb07262d2f72699271b7cb6c170b7a34bf763c2f2195c4616","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_24c1872edd3c444aab7090b24f","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070111.zip","SHA1Sum":"0da5e855d317f44d47e6b35a9895df0a27ea264a","SHA256Sum":"dae543bd7a32f8c15730d28f827899b5541208f49a5e574f760307b0484acab8","SHA512Sum":"6f9c3aef903d691e1c40c161f6b09ebb712e72db2e8cb8d21736e77983811002087647bde5ccbae4454a4aad6116ba168caa8b93bca6322da41b8ca0acd55dcd"}],"ComponentSizeInKB":5695,"CompsigList":["cp070111.compsig"],"FileList":["/cp070111.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070111.zip","SHA1Sum":"0da5e855d317f44d47e6b35a9895df0a27ea264a","SHA256Sum":"dae543bd7a32f8c15730d28f827899b5541208f49a5e574f760307b0484acab8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba94294b8f824b7997263118f9","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068653.exe","SHA1Sum":"ec8140c31ab69e09487811a2b32576841b5f3a35","SHA256Sum":"fa56b2951d63bd48e23d3d92b32fe35a74ddb4b6c3c0d69ca662a8306ad9d885","SHA512Sum":"94f814c719229efc9db1bb4e8e6628ad23d82b79912d107a169280ef561c02518fecf3f3515920688fcceb3b1d854ac2c91d46b787ce056b477e987b500898bc"}],"ComponentSizeInKB":4236,"CompsigList":["cp068653.compsig"],"FileList":["cp068653.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512ND9.rel"],"Name":"cp068653.exe","SHA1Sum":"ec8140c31ab69e09487811a2b32576841b5f3a35","SHA256Sum":"fa56b2951d63bd48e23d3d92b32fe35a74ddb4b6c3c0d69ca662a8306ad9d885","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_189d6977f8aa4eb9928f0801d6","SupportedDevices":["452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070840.zip","SHA1Sum":"7d7c302b2237adfd9b7b0f948e6613cd8cdb0659","SHA256Sum":"e79c396932245ff00db75f5e54d3b0109a8b4eaaf7f3c5acfb7263a31b4bb595","SHA512Sum":"3a1348834ed2c08e835af02b1ed90790020c89949402c5cd0188a4aed6b18f7bdc1e9a89b077712e31591b1790b23653e88db9b6eb75069a1e39bc388a9ff579"}],"ComponentSizeInKB":580,"CompsigList":["cp070840.compsig"],"FileList":["/cp070840.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/vib20/icen/INT_bootbank_icen_2.3.3.0-1OEM.900.0.24755229.vib","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/icen-8451177904462284908.xml","/Intel-icen_2.3.3.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-icen_2.3.3.0-1OEM.900.0.24755229.xml"],"Name":"cp070840.zip","SHA1Sum":"7d7c302b2237adfd9b7b0f948e6613cd8cdb0659","SHA256Sum":"e79c396932245ff00db75f5e54d3b0109a8b4eaaf7f3c5acfb7263a31b4bb595","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"icen","Version":"2.3.3.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.3.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.3.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7acf4ed3c2c34b6ca53e4278f6","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070629.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"88d50ac2661fe7f0f151cab4f11c85b169390a95","SHA256Sum":"82e0b42526ad4e422f3d203c87932cdbc332b1164ac480649b09d12d20d3853c","SHA512Sum":"49922bb3b7e3b73a6761871266a8f0ff306b12b7f2382a8281c3c34e8598c38457ccaae08874a2a501a3f1dad34794a0055beb801e7d3bfece7e14f38912d66e"}],"ComponentSizeInKB":2400,"CompsigList":["firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/CP070632.xml","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/cp070629.compsig","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/cp070629.zip","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070632.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070632.scexe"],"Name":"firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"88d50ac2661fe7f0f151cab4f11c85b169390a95","SHA256Sum":"82e0b42526ad4e422f3d203c87932cdbc332b1164ac480649b09d12d20d3853c","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ea1377b0d2b4dada100454a81","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070622.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"a87af09c10680356ebc7c8ea69f6939b4bf5d6e1","SHA256Sum":"15d5bdb9b1877d1f6b111226eb078fe3bcaf07123c96ccb825e7015b4937ecfb","SHA512Sum":"3b7a464953ecd1f15ffd0cb4c712195b0b2450b3848b56a251d3ec47feb137e8c7084b56081847026db8002e8dbd1a4750ec1611f4830e0c05e2f12698b33254"}],"ComponentSizeInKB":2400,"CompsigList":["firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/CP070625.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/cp070622.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/cp070622.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070625.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070625.scexe"],"Name":"firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"a87af09c10680356ebc7c8ea69f6939b4bf5d6e1","SHA256Sum":"15d5bdb9b1877d1f6b111226eb078fe3bcaf07123c96ccb825e7015b4937ecfb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9688f993fe7c4aacb645c85290","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070987.zip","SHA1Sum":"bca5296d0f9541698bfe7db46376533b7b7423d2","SHA256Sum":"79c8f1b0337be9579def423a3ba2b64621e61560b2b37331bd1e7a3d1fe2c9ba","SHA512Sum":"05e908a72fe9332ea50d610f3222c9c360196d6b577ec43b06f832e6058a02556982a7c70c903b90da0f51889f04d65f7792927b6b07535f4fd45c739fa7b2bc"}],"ComponentSizeInKB":32,"CompsigList":["cp070987.compsig"],"FileList":["/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip","/cp070987.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/vib20/nmst/MEL_bootbank_nmst_4.34.1.11-1OEM.900.0.24755229.vib","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vibs/nmst-5319458696017701934.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.xml"],"Name":"cp070987.zip","SHA1Sum":"bca5296d0f9541698bfe7db46376533b7b7423d2","SHA256Sum":"79c8f1b0337be9579def423a3ba2b64621e61560b2b37331bd1e7a3d1fe2c9ba","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2026.02.23","VibList":[{"Name":"nmst","Version":"4.34.1.11-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"net-mst kernel module driver component for VMware ESXi 9uX","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"nmst:4.34.1.11-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.34.1.11-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ebb932514aa840c6ba553450ad","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101315900221"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","I38","I41","I36","U34","U17","U34","P85","P89","U30","P89","U32","P89","U31","U20","U31","U20","U36","P86","U15","U15","U22","U41","P92","P99","U40","U21","U38","U38","I36","HPE Apollo 6500 Gen10 Plus (Chassis)","U19","U56","U61","U45","U25","U37","U24","U13","U12","U13","U14","U14","HPE Apollo sx40 Server","HPE Apollo pc40 Server","HPE Apollo kl20 Server","HPE Apollo am35 Server","I40","I43","I39","I40","I42","I37"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-82894b9e0a-HPG1-14.1.x86_64.rpm","SHA1Sum":"6ea357d1e942e6e735dc5f40925d67b6c3d94b6d","SHA256Sum":"69ea5e9f0ada52722cca3cade40bcf985f71b8fa6ad89c0c8ffe9e8f35c2d916","SHA512Sum":"3a5668ac293e534369a3c72c5735b1ee4536c77ba46ecda53acf280c7048aa657b4d7d4bc81c640896e4566d880a66766ec5728112fc86616bf6ca47288f131d"}],"ComponentSizeInKB":6130,"CompsigList":["firmware-hdd-82894b9e0a-HPG1-14.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/CP068847.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068847.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068847.scexe"],"Name":"firmware-hdd-82894b9e0a-HPG1-14.1.x86_64.rpm","SHA1Sum":"6ea357d1e942e6e735dc5f40925d67b6c3d94b6d","SHA256Sum":"69ea5e9f0ada52722cca3cade40bcf985f71b8fa6ad89c0c8ffe9e8f35c2d916","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f9966fcba4646cfb18939f7e1","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.deb","SHA1Sum":"d2dda7eb38a8ad9825c1a6ddbebd65fd292dd5ab","SHA256Sum":"608897f606848e37bf76918b0db3cbbfd98c5b4ed2e7a5dc4782a504bf32498e","SHA512Sum":"c8a6e86b0c318851b863f4e914196136767b9ef81bcf302f4b0e64490eca19a4fad58b08aed2bfee933ff38f95434145a59f9a1669c69c5382ee20db7fe31e96"}],"ComponentSizeInKB":6733,"CompsigList":["firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/CP071808.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/MPS7825Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071808.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071808.scexe"],"Name":"firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.deb","SHA1Sum":"d2dda7eb38a8ad9825c1a6ddbebd65fd292dd5ab","SHA256Sum":"608897f606848e37bf76918b0db3cbbfd98c5b4ed2e7a5dc4782a504bf32498e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3 and MZXLR7T6HALA-000H3  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_696664c5e09d42098393ad8af5","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-12304c1aca_0HPG6-2.1_amd64.deb","SHA1Sum":"5fdbbc738a916f3a737d7bd517d99d3aadb24bba","SHA256Sum":"5c40609ef1d739062eb79c42422145ecc191900c3b2b14dfaf093bbf16fc99f4","SHA512Sum":"695eb05cf2c4e4f34f0299504fc817036734f7089ca54502686853bf14b3b3f34632d77bc0832d06a9872be42e1e23138066885fadbb5de06d073d089db93ce2"}],"ComponentSizeInKB":4125,"CompsigList":["firmware-hdd-12304c1aca_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/CP071714.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071714.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071714.scexe"],"Name":"firmware-hdd-12304c1aca_0HPG6-2.1_amd64.deb","SHA1Sum":"5fdbbc738a916f3a737d7bd517d99d3aadb24bba","SHA256Sum":"5c40609ef1d739062eb79c42422145ecc191900c3b2b14dfaf093bbf16fc99f4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba0acc28c7684fd7a70ed9c0e3","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-i40e-2.28.16-1.rhel9u7.x86_64.rpm","SHA1Sum":"98e92d5cf81a1fea5b999003a530266f654594fe","SHA256Sum":"1a7d0b4e006c1903cc491855cfc1d4b6b5c1d341b9636f5dc380eb06d9e1d34e","SHA512Sum":"89cac967a789e89ff9a0e1acf6f9685a3cfe711a7c67a8091eaa77b1b354b9b7fe8408af87053fe4fcbd348dda785a6c51181fdd2d624a1b6ece8f60c4f7de6d"}],"ComponentSizeInKB":459,"CompsigList":["kmod-hp-i40e-2.28.16-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-i40e","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/33","./usr/lib/.build-id/33/5958437ed14754a42af9c730bac8dc4a5ec15d","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"Name":"kmod-hp-i40e-2.28.16-1.rhel9u7.x86_64.rpm","SHA1Sum":"98e92d5cf81a1fea5b999003a530266f654594fe","SHA256Sum":"1a7d0b4e006c1903cc491855cfc1d4b6b5c1d341b9636f5dc380eb06d9e1d34e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.28.16-1"},{"Checksum":[{"Filename":"kmod-hp-i40e-2.28.16-1.rhel9u6.x86_64.rpm","SHA1Sum":"93db42cae8eb335d673a301b9e98a43771b2c9de","SHA256Sum":"5f98b314e01ff3cd17a79e8a94495bedfe531fd621d72c4189aa634661a79e1e","SHA512Sum":"d45c4acfc41cafc2cb3b300bf2f5d322db97314f18bd830246ba1a5641c47f34d3f724248c6a5838f838e8ffba1aca1c2244021028b490063ea06d09e05d329d"}],"ComponentSizeInKB":415,"CompsigList":["kmod-hp-i40e-2.28.16-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-i40e","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/7b","./usr/lib/.build-id/7b/7e2a5da3d5dcfcd41860655177e33973382483","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"Name":"kmod-hp-i40e-2.28.16-1.rhel9u6.x86_64.rpm","SHA1Sum":"93db42cae8eb335d673a301b9e98a43771b2c9de","SHA256Sum":"5f98b314e01ff3cd17a79e8a94495bedfe531fd621d72c4189aa634661a79e1e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.28.16-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2a5f3e1df4984166aef333aaec","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072211.exe","SHA1Sum":"b989fb18b400175bd481bc80740b60c51143dafc","SHA256Sum":"b4b797450b7fbc9deb5d90912089d78b1c824b5cee06af7142f02fa957018ae6","SHA512Sum":"666df95e30d30d5bffbffb3bc9ed130eb35b5c1edb46005fb8ec69b52ac881a2899035c16e1696448c8aa36814d6fb927983f252a741b29f3e522ff2e51381ed"}],"ComponentSizeInKB":624,"CompsigList":["cp072211.compsig"],"FileList":["cp072211.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"Name":"cp072211.exe","SHA1Sum":"b989fb18b400175bd481bc80740b60c51143dafc","SHA256Sum":"b4b797450b7fbc9deb5d90912089d78b1c824b5cee06af7142f02fa957018ae6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"TypeOfChange":"0","Version":"1.1.0.0"}],"InstallationDependency":{},"Name":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"nvmeejectfix5.dll","SWKeyExpectedPath":"%ProgramFiles%\\nvmefix"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0f87f198423d4d10939ef6b615","SupportedDevices":["a6b1a447-382a-5a4f-8086-2020159000ea"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U36","U41","U33","U40","U39","U37","U38","U38","I43","I42","U45"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072355.zip","SHA1Sum":"9b7b4e1cffe13f7650b5fdad53820558e87e3581","SHA256Sum":"f486d6f1f329407a58ecc6eba5fba5d42c893fef053ee7dba71273b62b860a43","SHA512Sum":"9f2545bcedef2a8c411760891aa25f8606e05279df1855b3e2ac44617439d55f8032fa96f2f0d68bc66ca75fc8a48b50a792b67b2043cbb8efa88f03ef1b6a01"}],"ComponentSizeInKB":13623,"CompsigList":["cp072355.compsig"],"FileList":["/cp072355.xml","/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip","/ssacli2-component_6.65.11.0-0.zip/index.xml","/ssacli2-component_6.65.11.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip","/ssacli2-component_6.65.11.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vibs/ssacli2--6784777076922694234.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.11.0-0.xml"],"Name":"cp072355.zip","SHA1Sum":"9b7b4e1cffe13f7650b5fdad53820558e87e3581","SHA256Sum":"f486d6f1f329407a58ecc6eba5fba5d42c893fef053ee7dba71273b62b860a43","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.11.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.1 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.11.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a7ff1a6911524f75b9f7126152","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58565948","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58565a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58565a45","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58565946","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58565a41","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58565a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b58565a43","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","SHA1Sum":"a1992396bc7f3ca5335b7c4d42d1b4a539a7d68f","SHA256Sum":"f6e47615b74a8caa93eb06f71dbbcc31855fca777bb2113b3bb95f91ffc03110","SHA512Sum":"bad5e96610ac11070414253f053ae95bc89cff25424ac490307c9c456a07e7c1981b1176b0d2adaa2ccd0c2d33fd7780fa66cb18c11c9b877f32f8b3c93aebf1"}],"ComponentSizeInKB":2331,"CompsigList":[],"FileList":["Kioxia_CM7_KACM7ALSHPK4.HPb","Kioxia_CM7_KACM7ALSHPK4.xml","payload.json"],"Name":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","SHA1Sum":"a1992396bc7f3ca5335b7c4d42d1b4a539a7d68f","SHA256Sum":"f6e47615b74a8caa93eb06f71dbbcc31855fca777bb2113b3bb95f91ffc03110","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KXVYH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXVZD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXVZE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXVYF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXVZA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXVZB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KXVZC","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c536fa4fdef41e08d38b08ff1","SupportedDevices":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068746.exe","SHA1Sum":"5b98f2c5c86f788d1ee86cf7b3d3e7eadab8406b","SHA256Sum":"e65405412cc21b955e9b59950e25c11f464ac9672dd8254d11cbcd639852df39","SHA512Sum":"cf6779b87d26d352d129f5377ce9568d55a7d6af26b476a1aadc6499d777a1d55cb83b4619c14e5e48cabf3a90d23fbab68622f6319e899748b29f1e3c06e2d6"}],"ComponentSizeInKB":4307,"CompsigList":["cp068746.compsig"],"FileList":["cp068746.xml","cpqsetup.exe","HVLPeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068746.exe","SHA1Sum":"5b98f2c5c86f788d1ee86cf7b3d3e7eadab8406b","SHA256Sum":"e65405412cc21b955e9b59950e25c11f464ac9672dd8254d11cbcd639852df39","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_70a95b0733094a948f37a598b2","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","SHA1Sum":"a2d00408c228de1796f0120ddccd8473e7ede6bc","SHA256Sum":"91206b784baba0f3f8c897ca499f5f42d47e5d754e1178e97292b334db620fa2","SHA512Sum":"b94e12f407d6f31bb7e7ba0647ad7d0f3c8bdb78aea4e0e9539e123a8549277511594c586995dfc4ab746c2fc3dc21038edb26810c0354b23b2225fb01ce7bfd"}],"ComponentSizeInKB":5764,"CompsigList":["firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/CP068838.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068838.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068838.scexe"],"Name":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","SHA1Sum":"a2d00408c228de1796f0120ddccd8473e7ede6bc","SHA256Sum":"91206b784baba0f3f8c897ca499f5f42d47e5d754e1178e97292b334db620fa2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6022262f43ce41b4a042d38bde","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072402.zip","SHA1Sum":"27af254da905678e631b402d8cf6871021ec30fe","SHA256Sum":"c4cc99fa8d819df5c6d09c99978e9dafbf9b887b3b9c321b92b21579c505325e","SHA512Sum":"3885fdb64cd6bca25b03709bbc4f7273d0fa02c4cc7c4bf473ac1c2c38ba27fce2de464e77cee59ac7fa2146920e16e2621a1de9c574b0dc7689e89a7e48b94c"}],"ComponentSizeInKB":17944,"CompsigList":["CP072402.compsig"],"FileList":["/CP072402_BUILD_1.data","/CP072402.vmexe64","/CP072402.vmfile","/CP072402_VMw.zip","/CP072402.xml","/payload.json","/CP072402_VMw.zip/index.xml","/CP072402_VMw.zip/vendor-index.xml","/CP072402_VMw.zip/metadata.zip","/CP072402_VMw.zip/vib20/CP072402/HPE_bootbank_CP072402_HPG4.1-8.0.0.20613240.vib","/CP072402_VMw.zip/metadata.zip/vendor-index.xml","/CP072402_VMw.zip/metadata.zip/vmware.xml","/CP072402_VMw.zip/metadata.zip/vibs/CP072402--5173219045973136071.xml","/CP072402_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072402_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072402.zip","SHA1Sum":"27af254da905678e631b402d8cf6871021ec30fe","SHA256Sum":"c4cc99fa8d819df5c6d09c99978e9dafbf9b887b3b9c321b92b21579c505325e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072402","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a38d26f85b2a4a5baae2625e4c","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070904.zip","SHA1Sum":"8fc69fa0c87cc912cd0de3a87d86dc312dea7e15","SHA256Sum":"ca3b3bc0beef8c22a7ae2f316f7d4a73fc85026ffde4135ff349a581842948ad","SHA512Sum":"8331bd878ee38116b5e51aac4e6396f56549dcd0cf29142ea52e1dc01b1c34973e5d7781e9ae4d401ac328b691263b9267c53469d917b97286220de7eb2ecf74"}],"ComponentSizeInKB":19357,"CompsigList":["CP070904.compsig"],"FileList":["/CP070904_BUILD_5.data","/CP070904.vmexe64","/CP070904.vmfile","/CP070904_VMw.zip","/CP070904.xml","/payload.json","/CP070904_VMw.zip/index.xml","/CP070904_VMw.zip/vendor-index.xml","/CP070904_VMw.zip/metadata.zip","/CP070904_VMw.zip/vib20/CP070904/HPE_bootbank_CP070904_HPG5.5-8.0.0.20613240.vib","/CP070904_VMw.zip/metadata.zip/vendor-index.xml","/CP070904_VMw.zip/metadata.zip/vmware.xml","/CP070904_VMw.zip/metadata.zip/vibs/CP070904--8477651724788457943.xml","/CP070904_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070904_HPG5.5-8.0.0.20613240.xml"],"Name":"CP070904.zip","SHA1Sum":"8fc69fa0c87cc912cd0de3a87d86dc312dea7e15","SHA256Sum":"ca3b3bc0beef8c22a7ae2f316f7d4a73fc85026ffde4135ff349a581842948ad","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070904","Version":"HPG5.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f84cd5cb192c468f9ad5996508","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070636.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.rpm","SHA1Sum":"09be99fe750190cbe6a2e94801a84989039c750c","SHA256Sum":"b6013d4de0479f2d2ca14f385038f789deb26a2488c614c2fb33d595c7b2b86f","SHA512Sum":"7bf5a13f2d343e4c1a82adc496678f8a218e96ecab2032b45410afcb670cdad4409de14314ac92b287505e420bfdd4d67e73f0fb21eb299c43e99702c0e7810a"}],"ComponentSizeInKB":2398,"CompsigList":["firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/CP070638.xml","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/cp070636.compsig","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/cp070636.zip","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070638.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070638.scexe"],"Name":"firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.rpm","SHA1Sum":"09be99fe750190cbe6a2e94801a84989039c750c","SHA256Sum":"b6013d4de0479f2d2ca14f385038f789deb26a2488c614c2fb33d595c7b2b86f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3af67b67e9344b4da2f1bbc2d4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.20"}]},"Files":[{"Checksum":[{"Filename":"cp071577.exe","SHA1Sum":"c0bb24b19de9c24785bb23a71e8d2c2a71076b29","SHA256Sum":"9f1eb92e43125678f8b7e6b74b0b89cf5b7c046318bbd1e6fd810cbc42f278be","SHA512Sum":"221a6e93284608f35ed2a45829fc480ab1d7b88b68187e1f2f9cd30fa58191a6e11770170cc4165ff5c1ed4546ab8259ee81a62254abb8b18ab9b446d9ed2550"}],"ComponentSizeInKB":33462,"CompsigList":["cp071577_part1.compsig","cp071577_part2.compsig"],"FileList":["cp071577.xml","cpqsetup.exe","ilo5_320.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"Name":"cp071577.exe","SHA1Sum":"c0bb24b19de9c24785bb23a71e8d2c2a71076b29","SHA256Sum":"9f1eb92e43125678f8b7e6b74b0b89cf5b7c046318bbd1e6fd810cbc42f278be","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a6e1f0c68c146f1938c10197c","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","6.1","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","SHA1Sum":"872ff0bb863964a87047485163fac701d47e0f3f","SHA256Sum":"4c1b76c1cf88cad95a8abe4cb096bcfb99a15c836e040343463ae8abcc3bc41a","SHA512Sum":"db1a2847b26a6fce7cf07b545065b177c942877fd2da09b820847bd1a3a732aaf4983542a414026a40167584f207b89eea6e4497aab2d477302fe20a2068c704"}],"ComponentSizeInKB":4978,"CompsigList":["firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/CP068825.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068825.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068825.scexe"],"Name":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","SHA1Sum":"872ff0bb863964a87047485163fac701d47e0f3f","SHA256Sum":"4c1b76c1cf88cad95a8abe4cb096bcfb99a15c836e040343463ae8abcc3bc41a","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ca06346fe34e428ca900a93a55","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U50","U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"CP071597.zip","SHA1Sum":"8e34dc566aea5f4566a4bfe933121b7b392e6da1","SHA256Sum":"c101c6405318ebc15c2a3cb970615d5c27eb8216ac807d4941cd2cc5bdefbf4a","SHA512Sum":"162bb04ac835961b39e9fe796b45d8a6b449786519fa8a84ddfa6d6b53225e7309c9678430842fce9f7cd583bcbcb525390fc191748e782dbeccf7d31de534c2"}],"ComponentSizeInKB":16382,"CompsigList":["CP071597.compsig"],"FileList":["/CP071597_BUILD_1.data","/CP071597.vmexe64","/CP071597.vmfile","/CP071597_VMw.zip","/CP071597.xml","/payload.json","/CP071597_VMw.zip/index.xml","/CP071597_VMw.zip/vendor-index.xml","/CP071597_VMw.zip/metadata.zip","/CP071597_VMw.zip/vib20/CP071597/HPE_bootbank_CP071597_1.44.0.1-8.0.0.20613240.vib","/CP071597_VMw.zip/metadata.zip/vendor-index.xml","/CP071597_VMw.zip/metadata.zip/vmware.xml","/CP071597_VMw.zip/metadata.zip/vibs/CP071597--4649069573920731809.xml","/CP071597_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071597_1.44.0.1-8.0.0.20613240.xml"],"Name":"CP071597.zip","SHA1Sum":"8e34dc566aea5f4566a4bfe933121b7b392e6da1","SHA256Sum":"c101c6405318ebc15c2a3cb970615d5c27eb8216ac807d4941cd2cc5bdefbf4a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"1.44.0","VibList":[{"Name":"CP071597","Version":"1.44.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4232506c110944588db3380b14","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U47","U46","A42","A42","A43","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U46","U68","U72","U70","A66","A66","U77","U70"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071381.exe","SHA1Sum":"2998984c4031238eae8c6e4d3c6a25068c0bf965","SHA256Sum":"bb757be8e69f08e8899fc40931dfb810d0139da8542dc6f37a0ed0316ff8fd8b","SHA512Sum":"b1fe9b00f7ab17d505c45aacbfc7566b1efee7cc407bbc03e70ea40f22be52b7aef41d7f2fb1081bc71bc0542cd925177f091bda5365bf2f60156b804c898706"}],"ComponentSizeInKB":11344,"CompsigList":["cp071381.compsig"],"FileList":["cp071381.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_3.66_04_01_2026.signed.flash"],"Name":"cp071381.exe","SHA1Sum":"2998984c4031238eae8c6e4d3c6a25068c0bf965","SHA256Sum":"bb757be8e69f08e8899fc40931dfb810d0139da8542dc6f37a0ed0316ff8fd8b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_44a06ed0f55c4799a0d9153822","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070948.zip","SHA1Sum":"e3f23fc0924c6a5d9614dccfea21818498a2cc94","SHA256Sum":"98a2fddb62a5f1d43c2bbd01408be501ae75cd03d5d957e1e390189d4f1ecabf","SHA512Sum":"4f8be1afb317fb8b41d784c389a53dd947cc8809e494aa59a0667677952de780e98f8f1fc235156242242cfb140c33a86b2d227f855e1aa4170c0e57d4c40013"}],"ComponentSizeInKB":17642,"CompsigList":["CP070948.compsig"],"FileList":["/CP070948_BUILD_4.data","/CP070948.vmexe64","/CP070948.vmfile","/CP070948_VMw.zip","/CP070948.xml","/payload.json","/CP070948_VMw.zip/index.xml","/CP070948_VMw.zip/vendor-index.xml","/CP070948_VMw.zip/metadata.zip","/CP070948_VMw.zip/vib20/CP070948/HPE_bootbank_CP070948_HPD9.4-8.0.0.20613240.vib","/CP070948_VMw.zip/metadata.zip/vendor-index.xml","/CP070948_VMw.zip/metadata.zip/vmware.xml","/CP070948_VMw.zip/metadata.zip/vibs/CP070948--3210713049238804245.xml","/CP070948_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070948_HPD9.4-8.0.0.20613240.xml"],"Name":"CP070948.zip","SHA1Sum":"e3f23fc0924c6a5d9614dccfea21818498a2cc94","SHA256Sum":"98a2fddb62a5f1d43c2bbd01408be501ae75cd03d5d957e1e390189d4f1ecabf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070948","Version":"HPD9.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d44ca440cb54e9fb37887a240","SupportedDevices":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070553.exe","SHA1Sum":"dfa788253a859dcfbb41c160b92a887908474b78","SHA256Sum":"ed3f9dc9d20caa90920e5a2864344b6484c108e9bd5e9a3c17d54edd0f7b26e1","SHA512Sum":"368c7ffff30c7a1db703c970d3fd680ebacd3ef279935977d528140f65d80bdb7026e913d6e44c478541fdb8fb5863cdbb78719ec0284f0b2c7f148d9be51d56"}],"ComponentSizeInKB":1688,"CompsigList":["cp070553.compsig"],"FileList":["cp070553.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"Name":"cp070553.exe","SHA1Sum":"dfa788253a859dcfbb41c160b92a887908474b78","SHA256Sum":"ed3f9dc9d20caa90920e5a2864344b6484c108e9bd5e9a3c17d54edd0f7b26e1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.20.39.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bb3447a059d64fbba936fb336c","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U41_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071415.exe","SHA1Sum":"e154366db42ec0ec2d6393e9b063e190f7f5c243","SHA256Sum":"c16237b7056846387ec52c051e646c227c87388428c8abcfc7800287e83df963","SHA512Sum":"2d6621fef27e317ef3a1d33c759ffbf9128161f69edffaccd14e6633a7ce277eb2990f38b03fb0902d04caf7329b5599b797c927a0f292cdfaf63009136f8d94"}],"ComponentSizeInKB":11360,"CompsigList":["cp071415.compsig"],"FileList":["cp071415.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_3.66_04_01_2026.signed.flash"],"Name":"cp071415.exe","SHA1Sum":"e154366db42ec0ec2d6393e9b063e190f7f5c243","SHA256Sum":"c16237b7056846387ec52c051e646c227c87388428c8abcfc7800287e83df963","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_036952d54fc04512bd4f7d4d8d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"cp068623.exe","SHA1Sum":"6963bfbdefad95ee3eea3300a7a644285f15aad5","SHA256Sum":"e6a1df1c99d03f92f07b0fc9bf13fba7dd3d60d351e4201342752f9439f6b9a2","SHA512Sum":"ea0cc23ffb6a2b051f7916914fbf0cc63e9e6c2a45a604051a1ed1d0b49596e25aaa2bf022cdc7c1d8b7a830f4f4a67640c0b017ae8978f193d2dd358c965281"}],"ComponentSizeInKB":3417,"CompsigList":["cp068623.compsig"],"FileList":["4ICRHPK3.rel","cp068623.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068623.exe","SHA1Sum":"6963bfbdefad95ee3eea3300a7a644285f15aad5","SHA256Sum":"e6a1df1c99d03f92f07b0fc9bf13fba7dd3d60d351e4201342752f9439f6b9a2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c3565c0707884cfd8788bdb7d1","SupportedDevices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssaducli-6.65-9.0_amd64.deb","SHA1Sum":"54f071273116265e77f50ee4450cc780e608bcd1","SHA256Sum":"fcdfc8cfb5b56467560f7cf74f4dbf67358fbbfee1241a9f187efdaac9296329","SHA512Sum":"ade150830bed3a780fe7697ba060f2362b1e501e3babba12a336e30b81425b2278318462d29636f82986aa46db43f3dd5518ca5b7bf0a539bfc44266b03a7e9b"}],"ComponentSizeInKB":2816,"CompsigList":["ssaducli-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/sbin/ssaducli","./usr/share/doc/ssaducli/changelog.Debian.gz","./usr/share/doc/ssaducli/copyright","./usr/share/man/man8/ssaducli.8.gz","./usr/share/smartupdate/ssaducli/component.xml"],"Name":"ssaducli-6.65-9.0_amd64.deb","SHA1Sum":"54f071273116265e77f50ee4450cc780e608bcd1","SHA256Sum":"fcdfc8cfb5b56467560f7cf74f4dbf67358fbbfee1241a9f187efdaac9296329","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_394e276358864ea9a2e47f1143","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","I44","U63","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","U19","Carbondale14","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"CP070935.zip","SHA1Sum":"0d1ae151987962a8a0480d651efb03ec793c4803","SHA256Sum":"90b3b2a64ed618562b42164e4b50cf1f2db73eb3ffd4bf9f38ba24bd1a75801a","SHA512Sum":"e794d740806cfedd0db501f5693af9f35c1958da3c7221903e00aa289373e71d5f076612874b5991d827ec5190f0fd846072ae1fa3fd45ff1a11c927308d6380"}],"ComponentSizeInKB":19368,"CompsigList":["CP070935.compsig"],"FileList":["/CP070935_BUILD_5.data","/CP070935.vmexe64","/CP070935.vmfile","/CP070935_VMw.zip","/CP070935.xml","/payload.json","/CP070935_VMw.zip/index.xml","/CP070935_VMw.zip/vendor-index.xml","/CP070935_VMw.zip/metadata.zip","/CP070935_VMw.zip/vib20/CP070935/HPE_bootbank_CP070935_HPDD.5-8.0.0.20613240.vib","/CP070935_VMw.zip/metadata.zip/vendor-index.xml","/CP070935_VMw.zip/metadata.zip/vmware.xml","/CP070935_VMw.zip/metadata.zip/vibs/CP070935-491087659333760844.xml","/CP070935_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070935_HPDD.5-8.0.0.20613240.xml"],"Name":"CP070935.zip","SHA1Sum":"0d1ae151987962a8a0480d651efb03ec793c4803","SHA256Sum":"90b3b2a64ed618562b42164e4b50cf1f2db73eb3ffd4bf9f38ba24bd1a75801a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD","VibList":[{"Name":"CP070935","Version":"HPDD.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c7d2059d753742e59ed30b3ade","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","SHA1Sum":"1743ea6b0661b9e243936f4bab2c016bec404da3","SHA256Sum":"5b6e7f65ec68723ca9bf31054ebc2e54ec01f5d1440f1991a826ad9d6efe92e4","SHA512Sum":"45a6411ae938e45d353bd0408e409c4ae227354be912486442ad3159c6f7090a40fde22d179164fa4192baff4877be53742fe7e20eb031e1103c4edac30d57e7"}],"ComponentSizeInKB":5733,"CompsigList":["firmware-hdd-8a0371a425-HPDC-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/CP068858.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/TAMG08scHPDC.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068858.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068858.scexe"],"Name":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","SHA1Sum":"1743ea6b0661b9e243936f4bab2c016bec404da3","SHA256Sum":"5b6e7f65ec68723ca9bf31054ebc2e54ec01f5d1440f1991a826ad9d6efe92e4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_32c19a99dc72438aa00618642c","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b5a595755","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b5a595842","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b5a595843","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b5a595754","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b5a595756","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b5a595841","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"Solidigm_P5x20_4IAAHPK5.fwpkg","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","SHA512Sum":"7f6ac335147d901db5f8ecdb5300fc8c0211a5ab6044ca515ee8b103388bb46d7c8eaba827f450778ca0f40423c67c10c98e052ea20decd69ae2d905c5562f92"}],"ComponentSizeInKB":1559,"CompsigList":[],"FileList":["payload.json","Solidigm_P5x20_4IAAHPK5.HPb","Solidigm_P5x20_4IAAHPK5.xml"],"Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KZYWU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KZYXB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KZYXC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KZYWT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KZYWV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KZYXA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4412e3e7c98649b3bd32cc53ac","SupportedDevices":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_CQDA2_4p91_PLDMoMCTP_800214AF.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_4p91_PLDMoMCTP_800214AF.fwpkg","SHA1Sum":"3d2b7a1a3e29eba1dd3b30327d071c27535f8feb","SHA256Sum":"470e41cfca02f2c0f0d75c9232b06a094b22f89f573ce4cf0ddde90339486ffd","SHA512Sum":"f1ccc55e0f94fba74ef78c83717a0fa4202812b1f1c64958902c12f157ed86c35aa2855a59618d06549e32d54e3e820441bc79f1bbc8395bed1270244eb12f58"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_CQDA2_4p91_PLDMoMCTP_800214AF.HPb","HPE_E810_CQDA2_4p91_PLDMoMCTP_800214AF.xml","payload.json"],"Name":"HPE_E810_CQDA2_4p91_PLDMoMCTP_800214AF.fwpkg","SHA1Sum":"3d2b7a1a3e29eba1dd3b30327d071c27535f8feb","SHA256Sum":"470e41cfca02f2c0f0d75c9232b06a094b22f89f573ce4cf0ddde90339486ffd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ba069824fd74ad0839f78daf1","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069549.exe","SHA1Sum":"bebf37bcee88bd5bdf3a20b720e7ec020f97626d","SHA256Sum":"a81f4073aef93752777eccaf61efe595c00ac50cc335a13c1485739263db2f41","SHA512Sum":"1962a25d2107584cf94633174681f88eb3ee67fbcb69e759a5217a4edc8713098f303e92e9d985d50158b9263c9fffbb29203c4e04a13086bbc91b7fdcd6f8ca"}],"ComponentSizeInKB":1017,"CompsigList":["cp069549.compsig"],"FileList":["cp069549.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"Name":"cp069549.exe","SHA1Sum":"bebf37bcee88bd5bdf3a20b720e7ec020f97626d","SHA256Sum":"a81f4073aef93752777eccaf61efe595c00ac50cc335a13c1485739263db2f41","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixn Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0c703a78e2174310a9807b7cb6","SupportedDevices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp070086.exe","SHA1Sum":"8cbbdef6c0e95da728495a8815790e260bc69ebf","SHA256Sum":"07de0123992a92d0acb1b889bcbae6b5879829041d5681a122b6dd55b73aba1a","SHA512Sum":"1ba063ce3f13c9fa46aba28216802114f846d229f6340a68deec00c39a6b317841fd667d138caea9fdce9e4604d9fb8bcb48ef864e76f65ebb1bf718bb337f3e"}],"ComponentSizeInKB":4054,"CompsigList":["cp070086.compsig"],"FileList":["cp070086.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09acHPG6.REL"],"Name":"cp070086.exe","SHA1Sum":"8cbbdef6c0e95da728495a8815790e260bc69ebf","SHA256Sum":"07de0123992a92d0acb1b889bcbae6b5879829041d5681a122b6dd55b73aba1a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_481db77156ae459e8d2d236d7b","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"CP070858.zip","SHA1Sum":"3ecbe1a606f1d82e4cc36906fe0eb98d234747f4","SHA256Sum":"421abd6ab9825e7ef5842e000f4eb388df387aaeec35d98e92b2c206b775068d","SHA512Sum":"caa9e52d464c299efa61a9b59d4fd9bca1e0798a51b01b6637afb739bfb8c955e021e57956df5e484b99b211d6bad1f4d3dd94f529bb64795448bf9ba0c30c38"}],"ComponentSizeInKB":17211,"CompsigList":["CP070858.compsig"],"FileList":["/CP070858_BUILD_4.data","/CP070858.vmexe","/CP070858.vmexe64","/CP070858.vmfile","/CP070858_VMw.zip","/CP070858.xml","/payload.json","/CP070858_VMw.zip/index.xml","/CP070858_VMw.zip/vendor-index.xml","/CP070858_VMw.zip/metadata.zip","/CP070858_VMw.zip/vib20/CP070858/HPE_bootbank_CP070858_0.39.4-8.0.0.20613240.vib","/CP070858_VMw.zip/metadata.zip/vendor-index.xml","/CP070858_VMw.zip/metadata.zip/vmware.xml","/CP070858_VMw.zip/metadata.zip/vibs/CP070858--4070673512976042868.xml","/CP070858_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070858_0.39.4-8.0.0.20613240.xml"],"Name":"CP070858.zip","SHA1Sum":"3ecbe1a606f1d82e4cc36906fe0eb98d234747f4","SHA256Sum":"421abd6ab9825e7ef5842e000f4eb388df387aaeec35d98e92b2c206b775068d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39","VibList":[{"Name":"CP070858","Version":"0.39.4-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fba1755d98dd449caaab9c67d6","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","8.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","SHA1Sum":"0fe891cd8ec3ab3541428f295dba8efe4ddcd890","SHA256Sum":"bb1d89ecdb98ff30bbb9d01d827d8ed627ac1434ca33b12f944e1f0586b33211","SHA512Sum":"05320c64adb103dc7bb411d560b0ca857e9d07af0ca95e6f238c0b45b4aa763fef58185d992b5b0833c1a9997159ef20cdf92442cce632d85b50935d3b6d5504"}],"ComponentSizeInKB":6225,"CompsigList":["firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/CP068837.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068837.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068837.scexe"],"Name":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","SHA1Sum":"0fe891cd8ec3ab3541428f295dba8efe4ddcd890","SHA256Sum":"bb1d89ecdb98ff30bbb9d01d827d8ed627ac1434ca33b12f944e1f0586b33211","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c975c71029334580b2c010de25","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072376.zip","SHA1Sum":"2cc7404006156fa696e17c45971f30029451042c","SHA256Sum":"686c9d61876413b090308797d55be44fe774d6b0f83238d98017917df909e9e3","SHA512Sum":"ca588be7a70537f98301671b14e8564b1e85977fb31dd4effcb4f836f2f7fb973b0ce1dec3a68974bc6bd9c21ea780673a35817029ca7d6925ec29d8253fc97e"}],"ComponentSizeInKB":24219,"CompsigList":["CP072376.compsig"],"FileList":["/CP072376.xml","/CP072376_VMw.zip","/payload.json","/CP072376.vmexe64","/CP072376.vmfile","/CP072376_VMw.zip/index.xml","/CP072376_VMw.zip/vendor-index.xml","/CP072376_VMw.zip/metadata.zip","/CP072376_VMw.zip/vib20/CP072376/HPE_bootbank_CP072376_1.0.2-1OEM.900.0.24755229.vib","/CP072376_VMw.zip/metadata.zip/vendor-index.xml","/CP072376_VMw.zip/metadata.zip/vmware.xml","/CP072376_VMw.zip/metadata.zip/vibs/CP072376-5588480391762199828.xml","/CP072376_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072376_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072376.zip","SHA1Sum":"2cc7404006156fa696e17c45971f30029451042c","SHA256Sum":"686c9d61876413b090308797d55be44fe774d6b0f83238d98017917df909e9e3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072376","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aa3a6dd076ab43cea31d53e061","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"firmware-d6020-2.74-25.1.x86_64.rpm","SHA1Sum":"233c2f7172fbdeb07fe28da1ce1368b8e0ba8a1d","SHA256Sum":"ccc8794cc5882f426560d98c018ea145fbeb8f6538413eadec12ec5886377c68","SHA512Sum":"767c2f86f6f4d4332bf7a677fb47994e287bcfc9003d5c6137380e24153cbd3cec0c969a55331af45e3b4340e61899e8cb1918f8febfdc00022d79235c13e5d1"}],"ComponentSizeInKB":3579,"CompsigList":["firmware-d6020-2.74-25.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/CP072206.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072206.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072206.scexe"],"Name":"firmware-d6020-2.74-25.1.x86_64.rpm","SHA1Sum":"233c2f7172fbdeb07fe28da1ce1368b8e0ba8a1d","SHA256Sum":"ccc8794cc5882f426560d98c018ea145fbeb8f6538413eadec12ec5886377c68","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c4c68bcc3ffb4bb3a4c581225b","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068621.exe","SHA1Sum":"38a1c5c19ec14ce1171cc081a078a9d7e37aa4eb","SHA256Sum":"fcfc2072131aeefdfd8b13eac286e360314b445aae1d40444952aa81428f0e0b","SHA512Sum":"2a39cfa67bdbdfab4aebe5383fc68ca32e68c4dc40d3f8decfa923833cf596c22673c18c02667468d8ce6b60c9ea04335774f17998d47a789b744ebf32ea6330"}],"ComponentSizeInKB":3003,"CompsigList":["cp068621.compsig"],"FileList":["4IYVHPG5.rel","cp068621.xml","cpqsetup.exe","payload.json","setup.dll"],"Name":"cp068621.exe","SHA1Sum":"38a1c5c19ec14ce1171cc081a078a9d7e37aa4eb","SHA256Sum":"fcfc2072131aeefdfd8b13eac286e360314b445aae1d40444952aa81428f0e0b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_97f9bd5cfe0948f8812fc1eb5a","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069556.exe","SHA1Sum":"baf16b649044aab51fd3ea31b8a0ddfc936f26b6","SHA256Sum":"192b9b64b9ca65fc4cbe9d09ef858150a81edfa31c0886e3af3ab87789925086","SHA512Sum":"aa9ccbd4582a8a3ef8c82d0a81246ec0b5f18a6ddd0678cb1185c4da5750ca2dbd691c3de4d44877441eb98b3137391b4fcbcbfdefe2ef075f94cce7dc880567"}],"ComponentSizeInKB":834,"CompsigList":["cp069556.compsig"],"FileList":["cp069556.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"Name":"cp069556.exe","SHA1Sum":"baf16b649044aab51fd3ea31b8a0ddfc936f26b6","SHA256Sum":"192b9b64b9ca65fc4cbe9d09ef858150a81edfa31c0886e3af3ab87789925086","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"TypeOfChange":"1","Version":"2.1.252.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0e275b595b61436795ae02fc50","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071896.zip","SHA1Sum":"68dc76f3797564e3de6210555a477cb00d7ad695","SHA256Sum":"fbbe5e7c4e209d184c71df30d576dc30d6a4bc43580e43bbcb9c5595f725a1cc","SHA512Sum":"a2d9f32ba7bacaf7755768b94e189e66b6c200ed62465d4a47e5c35fde871585b60fdd34e5d8077e5341bf63f2a83b07a2c3f172fad9d6acebe5352607bbbb5e"}],"ComponentSizeInKB":343,"CompsigList":["cp071896.compsig"],"FileList":["/cp071896.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip","/MIS_bootbank_smartpqi_90.4902.0.103-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/vendor-index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/vib20/smartpqi/MIS_bootbank_smartpqi_90.4902.0.103-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vibs/smartpqi--6695129977023339273.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.xml"],"Name":"cp071896.zip","SHA1Sum":"68dc76f3797564e3de6210555a477cb00d7ad695","SHA256Sum":"fbbe5e7c4e209d184c71df30d576dc30d6a4bc43580e43bbcb9c5595f725a1cc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"smartpqi","Version":"90.4902.0.103-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 9.0 (Driver Component).","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Microchip-smartpqi:90.4902.0.103-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:90.4902.0.103-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_198e59df9cd946a39158461466","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U32","U46","A43","A43","A43","A41","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","A66","U71","A66","U68","U72","U68","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"CP072201.zip","SHA1Sum":"6e43acf483ff1667d1799d52ca1d95cc25703fec","SHA256Sum":"f741cfee18a3dafe61689a5e5bb1c0844d211e02789abf2f1c854ab73809e1ff","SHA512Sum":"44af0e81df0f494ee9c36fd34c6928864a317927765f34cf6b58cc5b047d8e034d4deb3320a43daf39b3afec4dcbed16366992a2871c805abf7292b0a7daacda"}],"ComponentSizeInKB":8094,"CompsigList":["CP072201.compsig"],"FileList":["/CP072201_BUILD_1.data","/CP072201.vmcfg","/CP072201.vmexe64","/CP072201.vmfile","/CP072201_VMw.zip","/CP072201.xml","/payload.json","/CP072201_VMw.zip/index.xml","/CP072201_VMw.zip/vendor-index.xml","/CP072201_VMw.zip/metadata.zip","/CP072201_VMw.zip/vib20/CP072201/HPE_bootbank_CP072201_2.74.1-8.0.0.20613240.vib","/CP072201_VMw.zip/metadata.zip/vendor-index.xml","/CP072201_VMw.zip/metadata.zip/vmware.xml","/CP072201_VMw.zip/metadata.zip/vibs/CP072201--7509126339200158816.xml","/CP072201_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072201_2.74.1-8.0.0.20613240.xml"],"Name":"CP072201.zip","SHA1Sum":"6e43acf483ff1667d1799d52ca1d95cc25703fec","SHA256Sum":"f741cfee18a3dafe61689a5e5bb1c0844d211e02789abf2f1c854ab73809e1ff","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74","VibList":[{"Name":"CP072201","Version":"2.74.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_402bcd7460114831b54fa922f2","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.fwpkg","SHA1Sum":"c22630112fa8ce536f4682996fa74aadc95a9f8e","SHA256Sum":"46fc159c072d28a503f397490f39ab471109825affcbc30c987a5543578120a2","SHA512Sum":"48526d30e0ccbb8f17bcd6ef3d2524225dea26dd9929f6f819658778e3ed3f59e1642640bbc45a5969ed4e84a61d336895772f2f8355675c9be34e539161ab0b"}],"ComponentSizeInKB":5523,"CompsigList":[],"FileList":["16_35_8008-MCX515A-CCA_HPE_Ax.pldm.signed","16_35_8008-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"Name":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.fwpkg","SHA1Sum":"c22630112fa8ce536f4682996fa74aadc95a9f8e","SHA256Sum":"46fc159c072d28a503f397490f39ab471109825affcbc30c987a5543578120a2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715900346"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX515A-CCAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4dcbfa450d7e4f94a5cb148a3a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900346"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U34","U34","U30","P89","U32","P89","U36","U22","U41","HPE ProLiant SL4500 Chassis","U40","U39","U45","U25","U37","U38","U38","HPE Apollo 6500 Gen10 System","U39","U19"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"storcli-007.3604.0000.0000-1.noarch.rpm","SHA1Sum":"faa300d30c6ba6559a8dd4aadcf95197d1a2fa08","SHA256Sum":"685f5075607ec0297e0d750be0fb976af63df89b9083c6bf77d0aa7a2b97b465","SHA512Sum":"4be6552d0c54d62f2b5af6709f589389795d90325017d5e684d3f491e142c6e0a50fd39b34085e5a04e0f7ad9b058dd98e60ac233df601b62922bbcbfaea1ebf"}],"ComponentSizeInKB":2650,"CompsigList":["storcli-007.3604.0000.0000-1.noarch.compsig"],"FileList":["./opt/MegaRAID/storcli/storcli","./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"Name":"storcli-007.3604.0000.0000-1.noarch.rpm","SHA1Sum":"faa300d30c6ba6559a8dd4aadcf95197d1a2fa08","SHA256Sum":"685f5075607ec0297e0d750be0fb976af63df89b9083c6bf77d0aa7a2b97b465","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3604.0000.0000"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_174fd416142d4649aa647bf3a8","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068885.zip","SHA1Sum":"bbe76d56b14b6e61624e3fefec66533f9a1aa5d3","SHA256Sum":"9c1dab144147547ffbd7206c0efa38be68b36845443b522060561fb6e063022e","SHA512Sum":"af612e4d621eea201a2db15b026ded8510f52ef90691ccb9aa003c66bc5e25adc264bfd6131c5758430a22f238488f8898e837cc728e55854cc320b0fc364bd5"}],"ComponentSizeInKB":201,"CompsigList":["cp068885.compsig"],"FileList":["/BCM_bootbank_lsi-mr3_7.736.02.00-1OEM.900.0.24755229.vib","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip","/cp068885.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.736.02.00-1OEM.900.0.24755229.vib","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/metadata.zip/vibs/lsi-mr3--5507153851849159233.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.736.02.00-1OEM.900.0.24755229.xml"],"Name":"cp068885.zip","SHA1Sum":"bbe76d56b14b6e61624e3fefec66533f9a1aa5d3","SHA256Sum":"9c1dab144147547ffbd7206c0efa38be68b36845443b522060561fb6e063022e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"lsi-mr3","Version":"7.736.02.00-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-lsi-mr3:7.736.02.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.736.02.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7eaf15c47df143f49aab9806e1","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U32","A43","A43","U61","A42","U60","U46","A43","A42","U65","U65","I46","U72","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"192da1f6675ae43b202c36917bae35383bb2ccac","SHA256Sum":"de818b35e4d202af32e1f8df0d0172412a023a5867f2f39d50ba4a42bedd1c3d","SHA512Sum":"7cb986c91a849d48a135255a17573747f234e1432034e1bfd987edc4d6de13abc905559442d9ec3262c6a3368c6f16f436b43c182499654a09c5f1871112432d"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"192da1f6675ae43b202c36917bae35383bb2ccac","SHA256Sum":"de818b35e4d202af32e1f8df0d0172412a023a5867f2f39d50ba4a42bedd1c3d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_78cb53d697014ce796cce57d53","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.rpm","SHA1Sum":"bf1d4027be16ccf32ae485866cdffb2764e7d4ea","SHA256Sum":"e67a5f1464f1387c42c579cb1abbeb34947c10405fe286ad741436a2deea323f","SHA512Sum":"41d912623d3a23a7a2da3759ad314335179d8c5dc4db2cf50a722790baa267534e1ed7faa1cad3347b53fb537c2374367734ea3c7a44853111f5cd54601d5ae6"}],"ComponentSizeInKB":3289,"CompsigList":["firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/CP072378.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072378.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072378.scexe"],"Name":"firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.rpm","SHA1Sum":"bf1d4027be16ccf32ae485866cdffb2764e7d4ea","SHA256Sum":"e67a5f1464f1387c42c579cb1abbeb34947c10405fe286ad741436a2deea323f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.10"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fbf1b708f83c4ea7a20f0bf507","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","7.0","8.0","11.0","12.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","U32","A43","A43","A43","A47","A48","U40","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","U61","U37","A42","U56"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a40-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"d7b2ebc4c96a7ff7f42fa725997e76d6c5826beb","SHA256Sum":"3ec0d4961355f8506e94e37bbc4e0cc9c8ac85c5bac9dd1f7dc0aba062600ba2","SHA512Sum":"3e361f290647d839195a30bc1f9e1802f5bdb3471ea4b3cdbc4e702d825850d4c6285a199efc1b3c52b9f0f3dd02b500c14d6dddbf593b8d0ed5b4d8578defdb"}],"ComponentSizeInKB":17609,"CompsigList":["firmware-system-a40-3.80_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/A40_3.80_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/CP072017.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072017.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072017.scexe"],"Name":"firmware-system-a40-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"d7b2ebc4c96a7ff7f42fa725997e76d6c5826beb","SHA256Sum":"3ec0d4961355f8506e94e37bbc4e0cc9c8ac85c5bac9dd1f7dc0aba062600ba2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c6a1656defb24fbaa92badd433","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069585.exe","SHA1Sum":"45016bfe2fb59461b84aee0821288b120871583f","SHA256Sum":"362a82f7b1b8efbbe0d43dd936b27a0d56a7cc9b4dea71cad9b2c7c5bf8a59e6","SHA512Sum":"e2543668677ac9f5a8bc2b5f780d6419584317d849134777820312084f9540eef0635d247e1212568b137558958437fa4e7152e8d22cfebb35a0c846f033824c"}],"ComponentSizeInKB":868,"CompsigList":["cp069585.compsig"],"FileList":["cp069585.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"Name":"cp069585.exe","SHA1Sum":"45016bfe2fb59461b84aee0821288b120871583f","SHA256Sum":"362a82f7b1b8efbbe0d43dd936b27a0d56a7cc9b4dea71cad9b2c7c5bf8a59e6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers Driver for Microsoft Windows 2019 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_49fe9081c9ee40c6ad89c24ecc","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"cp068657.exe","SHA1Sum":"b6b07de380f82f0c822493a1fab3e60ba2c5a826","SHA256Sum":"5174318587325cc3f333e1fbc5a0275c40cd1ec18b1d26a04a7e1594fd96c943","SHA512Sum":"f36096bd92156aafdb79258c196acc54747ef29adaa0a0a75b51a233c30d9db25bd75669bd33bd84b4ef13b2213fd01214705e41863f4c095f52b63ec83fcf11"}],"ComponentSizeInKB":4025,"CompsigList":["cp068657.compsig"],"FileList":["cp068657.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTEDD.rel"],"Name":"cp068657.exe","SHA1Sum":"b6b07de380f82f0c822493a1fab3e60ba2c5a826","SHA256Sum":"5174318587325cc3f333e1fbc5a0275c40cd1ec18b1d26a04a7e1594fd96c943","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_abfd69e9a7e643a8a89639344b","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.11"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.11"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.11"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.11"}]},"Files":[{"Checksum":[{"Filename":"cp070515.exe","SHA1Sum":"86cd04f673d59d615da234abdf2eea85d5411341","SHA256Sum":"02144797e69877c3441e4394adadc35083b947cc9fb1eb8eba7a49e2d8f59684","SHA512Sum":"aa6e40ea29d1d34f3a7061184b8910fe8622e5d3e9aa8c11447209bf0c0b7e2b726d95a3e919bc6260a6becf59c0bd88740d25bd2390c6fceb2abaec9e8480ef"}],"ComponentSizeInKB":3758,"CompsigList":["cp070515.compsig"],"FileList":["QLAFWUpdate.exe","adapters.properties","bk020501.bin","cp070515.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021111.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"Name":"cp070515.exe","SHA1Sum":"86cd04f673d59d615da234abdf2eea85d5411341","SHA256Sum":"02144797e69877c3441e4394adadc35083b947cc9fb1eb8eba7a49e2d8f59684","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.04.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2025 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":250,"RebootRequired":"yes","SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_214e027232994194ae8fe7a78f","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.rpm","SHA1Sum":"dc6a20049b096955362ad5c2c4f3f6f5949a3f58","SHA256Sum":"4ed6208e8e629204cf3d4811b917dde973afe11fa5911687afe4c9bf09c28121","SHA512Sum":"15e06034963fc72fecbfb67d0696fc94026bfc50defc7c2ecf4cacdf1ff6978ea60c17918ff8990ccf68b5cf98509db5b2d3ae5e58685b8ba91ca69de516a3c4"}],"ComponentSizeInKB":836,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.rpm","SHA1Sum":"dc6a20049b096955362ad5c2c4f3f6f5949a3f58","SHA256Sum":"4ed6208e8e629204cf3d4811b917dde973afe11fa5911687afe4c9bf09c28121","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Server Update 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c78fd5e00924adda4bc86d129","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"cp068664.exe","SHA1Sum":"aca88b0a26fc62634eac587eac2ae310f73622bb","SHA256Sum":"62c04c5d2325ef39b349f4b51f2d77da6d1888819c33b5707ca20796515d8b88","SHA512Sum":"c218a0a64a5590c1510e68842e4f1aca67a9687e85db5dfd4a49798741299d8db99ce3a714227e22d91e96aea31d4b4a53147c99066b0e40e67cb8a58faf1bfb"}],"ComponentSizeInKB":3927,"CompsigList":["cp068664.compsig"],"FileList":["cp068664.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNETG8.rel","setup.dll"],"Name":"cp068664.exe","SHA1Sum":"aca88b0a26fc62634eac587eac2ae310f73622bb","SHA256Sum":"62c04c5d2325ef39b349f4b51f2d77da6d1888819c33b5707ca20796515d8b88","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e9dad618e5094f738b2218775c","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-ixgbe-6.3.4-1.rhel9u6.x86_64.rpm","SHA1Sum":"490f2e132499f73be6013502fcf8d55fe0adfea5","SHA256Sum":"514d30cdb7ab43629cda168a120898052e88be04d9f21558afadf3d1420d3abf","SHA512Sum":"eb5ad518fd5ef391b643b68b98800a166dfa77b8d340739e34cdd5ece15025b3d578b79d5150d39cf7284fed6da4ccc657ed89a537120f90cc970d270f661cd3"}],"ComponentSizeInKB":364,"CompsigList":["kmod-hp-ixgbe-6.3.4-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/c5","./usr/lib/.build-id/c5/6a98e4ec5548e562e65dfa3100a5089d547dab","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"Name":"kmod-hp-ixgbe-6.3.4-1.rhel9u6.x86_64.rpm","SHA1Sum":"490f2e132499f73be6013502fcf8d55fe0adfea5","SHA256Sum":"514d30cdb7ab43629cda168a120898052e88be04d9f21558afadf3d1420d3abf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.3.4-1"},{"Checksum":[{"Filename":"kmod-hp-ixgbe-6.3.4-1.rhel9u7.x86_64.rpm","SHA1Sum":"a928495e365df2023e3c239b4df4e7b9606d7ec4","SHA256Sum":"8c3f84a57fa1d0f4059fdd4957390fa11da7ddea7d5582bef99bc0898687cfd2","SHA512Sum":"2bae1d6019c570a482f5a1f7a54a2abd99eede2cc46f4ab17df874324e58feacc76b750023ab2e77ebb8b1f596121b7312aea1bc8f459191b00c4da5c088fcb9"}],"ComponentSizeInKB":373,"CompsigList":["kmod-hp-ixgbe-6.3.4-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/ea3e00fb11a688d1cb1ce3faf2b9351282545b","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"Name":"kmod-hp-ixgbe-6.3.4-1.rhel9u7.x86_64.rpm","SHA1Sum":"a928495e365df2023e3c239b4df4e7b9606d7ec4","SHA256Sum":"8c3f84a57fa1d0f4059fdd4957390fa11da7ddea7d5582bef99bc0898687cfd2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.3.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ee3b0819b2024a92830837bbe2","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071480.zip","SHA1Sum":"b5c7cd7a26b707dac0298011e42b4ed44daac98e","SHA256Sum":"b9dcdaf8ed050877b8e068f40f27807fdf31538cdc273804449ca303b0be594b","SHA512Sum":"cab58a6c599c5aaab656bb3f973a360dccda5f76be2fbb9431b630aa229c51ae349cdb6dc2a686146a274fcc4c31abd1bff25b8fcebdf75f9255b57f429efeb4"}],"ComponentSizeInKB":378,"CompsigList":["cp071480.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip","/cp071480.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_237.1.132.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_237.1.132.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtroce-568144076460741377.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtnet--578145040878030357.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.xml"],"Name":"cp071480.zip","SHA1Sum":"b5c7cd7a26b707dac0298011e42b4ed44daac98e","SHA256Sum":"b9dcdaf8ed050877b8e068f40f27807fdf31538cdc273804449ca303b0be594b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2026.05.00","VibList":[{"Name":"bnxtroce","Version":"237.1.132.0-1OEM.900.0.24755229"},{"Name":"bnxtnet","Version":"237.1.132.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:237.1.232.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:237.1.132.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:237.1.132.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27e24777798a4127b6f6b27135","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U46","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.76 (05/28/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072034.exe","SHA1Sum":"3c3ae80a9d81fc7b890d91de0a92949f1f1535f3","SHA256Sum":"58865c692bf960fcf3627a635cf2c9d4fec6a30ddf6fb7fe6b40d8f896c365db","SHA512Sum":"400667c419d51f821b47450c8966e1695b4c479987e997d53f59d789ae41ef79d04b8c837db9352c249a9663bc3b0926a949bff572a6fff8190b1dcbb8a1e4f6"}],"ComponentSizeInKB":8767,"CompsigList":["cp072034.compsig"],"FileList":["cp072034.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_3.76_05_28_2026.signed.flash"],"Name":"cp072034.exe","SHA1Sum":"3c3ae80a9d81fc7b890d91de0a92949f1f1535f3","SHA256Sum":"58865c692bf960fcf3627a635cf2c9d4fec6a30ddf6fb7fe6b40d8f896c365db","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e5f6d5aeca9a40f384e5f97d0e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U48"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070975.zip","SHA1Sum":"0f0111a979f76a6c66383666dbaf04e28edbb8aa","SHA256Sum":"3f0e081c81171a61d995e7d38ef5ab00cb93f1151b880089bbfefdcdf17698d9","SHA512Sum":"ad58eaad34793f6bfc0dcb789d927baecf2902328d52587f73c4a7a8467399564510b691c615b815ca78f8bd38ef51c38f9a89076653fbbc809db8e04888dfb0"}],"ComponentSizeInKB":19204,"CompsigList":["CP070975.compsig"],"FileList":["/CP070975_BUILD_1.data","/CP070975.vmexe64","/CP070975.vmfile","/CP070975_VMw.zip","/CP070975.xml","/payload.json","/CP070975_VMw.zip/index.xml","/CP070975_VMw.zip/vendor-index.xml","/CP070975_VMw.zip/metadata.zip","/CP070975_VMw.zip/vib20/CP070975/HPE_bootbank_CP070975_HPG3.1-8.0.0.20613240.vib","/CP070975_VMw.zip/metadata.zip/vendor-index.xml","/CP070975_VMw.zip/metadata.zip/vmware.xml","/CP070975_VMw.zip/metadata.zip/vibs/CP070975--6893248138539057085.xml","/CP070975_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070975_HPG3.1-8.0.0.20613240.xml"],"Name":"CP070975.zip","SHA1Sum":"0f0111a979f76a6c66383666dbaf04e28edbb8aa","SHA256Sum":"3f0e081c81171a61d995e7d38ef5ab00cb93f1151b880089bbfefdcdf17698d9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070975","Version":"HPG3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cdeedd7c8b84433196596bb951","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-iavf-4.13.20-1.rhel9u6.x86_64.rpm","SHA1Sum":"e85616123468552da16e8db8ec3b953a1305dc75","SHA256Sum":"24cd96772bc89b7244ea8e0d7353dd59288615437975afa933fab2c7dc190df3","SHA512Sum":"00487f81ff84748037390bf05edf72040a87c88e7a67605636f90f87dcecbcbba93b876f8fba37c4f09154bfa5ea1f87a301d02fa2aef96933d16190061c3ca2"}],"ComponentSizeInKB":176,"CompsigList":["kmod-hp-iavf-4.13.20-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-iavf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/aa","./usr/lib/.build-id/aa/465165a1c5d2cc4ba2b94b17538896f846cd69","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"Name":"kmod-hp-iavf-4.13.20-1.rhel9u6.x86_64.rpm","SHA1Sum":"e85616123468552da16e8db8ec3b953a1305dc75","SHA256Sum":"24cd96772bc89b7244ea8e0d7353dd59288615437975afa933fab2c7dc190df3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.20-1"},{"Checksum":[{"Filename":"kmod-hp-iavf-4.13.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"c5a85a1fd33e23a72f8f5832100d0bcce3f25ac7","SHA256Sum":"3873890e366942eb6f5a06af29ee4a7d47b470838f51086ea6669bbeaa389966","SHA512Sum":"ce3f95fb2082bc19a92173d1451e661c314397679f038a41efe8c1652d0e39fa24d4976e95bd46352aa9a3f1e9815ba0f12ac3abed06196e11c122fbfa3d6738"}],"ComponentSizeInKB":188,"CompsigList":["kmod-hp-iavf-4.13.20-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-iavf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/a84bbe9dfc4e665651225cc8b5806fbdf06de7","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"Name":"kmod-hp-iavf-4.13.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"c5a85a1fd33e23a72f8f5832100d0bcce3f25ac7","SHA256Sum":"3873890e366942eb6f5a06af29ee4a7d47b470838f51086ea6669bbeaa389966","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.20-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_431bcf46da794f4b882c6a8f1c","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070483.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.925"}]},"Files":[{"Checksum":[{"Filename":"cp070484.exe","SHA1Sum":"1b4891ad60588c73ebd533d1b736e77f8ecb22db","SHA256Sum":"2fd79171f854fb9df0ed1826c97db8a3abd62ab9c5fdeb50c1d870ea866a4325","SHA512Sum":"5bdd96923494d07d79d904b859cc2972bda591e4022db5d4e63155381e89dce33c88d1134cc02dfa5ba25de3aa34a8e75a41380132b950a033d3bc0209fc09b0"}],"ComponentSizeInKB":8842,"CompsigList":["cp070484.compsig"],"FileList":["cp070483.compsig","cp070483.zip","cp070484.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070484.exe","SHA1Sum":"1b4891ad60588c73ebd533d1b736e77f8ecb22db","SHA256Sum":"2fd79171f854fb9df0ed1826c97db8a3abd62ab9c5fdeb50c1d870ea866a4325","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.925"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8dedd1ed8f0542f4a579438da5","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp068755.exe","SHA1Sum":"cc2c8c496b4f8a81b72dff444491b102b404631e","SHA256Sum":"1232aaa1c1f0ad62e08629437e188125e6711e22c7cef9cfc53927ce53d065dd","SHA512Sum":"723573005669a3cf64ea96a45db0c39a92ead6fda9ff68c0b07dde67b73eee52569bcad9095afc9e4841344705cc6312f95767af04178415c85ece3b8796d071"}],"ComponentSizeInKB":3200,"CompsigList":["cp068755.compsig"],"FileList":["cp068755.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06ACHPG6.REL"],"Name":"cp068755.exe","SHA1Sum":"cc2c8c496b4f8a81b72dff444491b102b404631e","SHA256Sum":"1232aaa1c1f0ad62e08629437e188125e6711e22c7cef9cfc53927ce53d065dd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_88b39410f2fd41e3a7c608a388","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070563.exe","SHA1Sum":"7b7d5c7992a207b926393932fc79da69efa831d6","SHA256Sum":"951f24868489c3d9419d597d2ced90d09d65636782c7bcca205c9da83217dc4f","SHA512Sum":"bce0957e51f31ae10f3207f12e45407ccc0e736ed28e7e7ee20d17fb5ff1e02f4a982cef808da7d050b541d76214a5e32e5176bde8533f6364546b4d699fc4d2"}],"ComponentSizeInKB":1386,"CompsigList":["cp070563.compsig"],"FileList":["cp070563.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp070563.exe","SHA1Sum":"7b7d5c7992a207b926393932fc79da69efa831d6","SHA256Sum":"951f24868489c3d9419d597d2ced90d09d65636782c7bcca205c9da83217dc4f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.18.161.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2782e9828ea24cbfb4448825ce","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","SHA1Sum":"b1bb096ab0886b6fe4af19db55bd1a4a71df5e9c","SHA256Sum":"1c5da7435c7e896f1d27219528d9f9ed4f79ec18a72b135baa7026a315ddb3eb","SHA512Sum":"dab1642a00e2f719ae9419291930e780062d1cb691e24254a10dac4c801337dfb65ef81a2bf5a5378b8538aad5c5c4f5bf486c8c11509e0d1d2b21544ba027db"}],"ComponentSizeInKB":5377,"CompsigList":["firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/CP068855.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068855.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068855.scexe"],"Name":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","SHA1Sum":"b1bb096ab0886b6fe4af19db55bd1a4a71df5e9c","SHA256Sum":"1c5da7435c7e896f1d27219528d9f9ed4f79ec18a72b135baa7026a315ddb3eb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7123f9b68d74ac2a66fa30f9b","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072294.exe","SHA1Sum":"b9ec83849c8e42130d52c335c2632ed2d492d0aa","SHA256Sum":"55e4ae14c098b45d03384662a2a80bc8848a9f37541e155f6d8884d4d7a331fe","SHA512Sum":"5c0cf8f91493e5c31c74ac3b12c805ec1e39d298a4944caba25cfc90da14bfdd04b6b2f65001ae2a00c66e4b7e9ad540c068f11f89a54430cdfe6581ebcf05ea"}],"ComponentSizeInKB":602,"CompsigList":["cp072294.compsig"],"FileList":["cp072294.xml","cpqsetup.exe","installer.dll","pnp/","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"Name":"cp072294.exe","SHA1Sum":"b9ec83849c8e42130d52c335c2632ed2d492d0aa","SHA256Sum":"55e4ae14c098b45d03384662a2a80bc8848a9f37541e155f6d8884d4d7a331fe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19006.8299"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_139acb881eb2411c8512277544","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","I43","I42","03020101","02020001","U39","U40","I41","U36","U45","U37","U38","U38","H08","H08","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"iavf-kmp-default-4.13.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"a1944a1767d1649f7857e271e4e35cc2a746d3ff","SHA256Sum":"c2e5c783610bd2fb21d9bd4531aec491cb31d083b1a92bbf5325f0ff78299318","SHA512Sum":"1b95421abe873f99e12e464b92391970751bea9b3d497095bf1dc831cd2a1b0268cf61c8dd7eafd449fe7f2b5cc3734444880a50f36b24f33009ec46a0eb1a65"}],"ComponentSizeInKB":218,"CompsigList":["iavf-kmp-default-4.13.20_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/iavf.ko","./usr/share/doc/packages/iavf-kmp-default","./usr/share/doc/packages/iavf-kmp-default/COPYING","./usr/share/doc/packages/iavf-kmp-default/README","./usr/share/man/man7/iavf.7.gz","./usr/share/pci.ids.d/pci.ids.iavf-kmp-4.13.20","./usr/share/smartupdate/iavf-kmp-default/component.xml"],"Name":"iavf-kmp-default-4.13.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"a1944a1767d1649f7857e271e4e35cc2a746d3ff","SHA256Sum":"c2e5c783610bd2fb21d9bd4531aec491cb31d083b1a92bbf5325f0ff78299318","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec99229626"],"TypeOfChange":"1","Version":"4.13.20-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ffa72cc6dc6f4096b3f3a27e06","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U31_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U31_3.66_04_01_2026.fwpkg","SHA1Sum":"0952561649b4d922fc711c7e49cd05cbf50fbbad","SHA256Sum":"991d4aa14891151f79cde3d130e4a2119034100b6da9b2845478f1578763f45c","SHA512Sum":"1d99a0144732bcb8112cfc6f9abbe3669c0f6d13ff1e82d4d6ae5516d5de808e8f4e8fb1067ed25573d53ce62956141bce7e4da88a605270a8d7bc4f8c852b08"}],"ComponentSizeInKB":32826,"CompsigList":[],"FileList":["payload.json","U31_3.66_04_01_2026.signed.flash","U31_3.66_04_01_2026.xml"],"Name":"U31_3.66_04_01_2026.fwpkg","SHA1Sum":"0952561649b4d922fc711c7e49cd05cbf50fbbad","SHA256Sum":"991d4aa14891151f79cde3d130e4a2119034100b6da9b2845478f1578763f45c","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ab2dc17085dc400b9d000acd54","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072095.exe","SHA1Sum":"135af32a09060d7a899431988304d310aebf38ed","SHA256Sum":"c142bb0d5d47df73c4312dca608b2ad04f31799e42f550220ce3a150573b2cb0","SHA512Sum":"57af915635523f16e1309e8546814d12c66fab17f4f2d718cf453e887577309e41ebc44f8c6a451c34165b8cd3aab811e96348542bd15d90f1bbd8efd0736e00"}],"ComponentSizeInKB":10194,"CompsigList":["cp072095.compsig"],"FileList":["cp072095.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSA66590_X64.msi"],"Name":"cp072095.exe","SHA1Sum":"135af32a09060d7a899431988304d310aebf38ed","SHA256Sum":"c142bb0d5d47df73c4312dca608b2ad04f31799e42f550220ce3a150573b2cb0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssa.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0211f99c09934b039fd5186f8f","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","A46","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","O43","U48","I44","I45","U58","U58","U63","A56","A56","U54","A55","U54","U58","A55","U59","U63","U54","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U65","U65","U57","U62","U68","U68","U72","A66","A66","U68","U71","U71"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.rpm","SHA1Sum":"a285526d4212cb4adc239882b80e674fd0fefcdb","SHA256Sum":"924feb0bd1a9093e736600cccc6450e4e7a1deedc4c999b951d4fa671f3c47cb","SHA512Sum":"e641bf3b3fc24a08beb479b907154de10219a8af3f1505f27940117d0b05a99b07af0dbd96c73393ed98e4616a11d9b604955125145cd20d703113cdc36ba117"}],"ComponentSizeInKB":5605,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.rpm","SHA1Sum":"a285526d4212cb4adc239882b80e674fd0fefcdb","SHA256Sum":"924feb0bd1a9093e736600cccc6450e4e7a1deedc4c999b951d4fa671f3c47cb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Update 2 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_883046cafe6a4dcf85f131dc57","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8173816d98_0HPD6-2.1_amd64.deb","SHA1Sum":"3cc121fb184d5a28e5e34fd587cc0cb41ff510e7","SHA256Sum":"94405ce7e7a5d15d303d91d6875f4d04cf045098a67d0b62f73fcb018c597a05","SHA512Sum":"bbf0be47689a7cc4c6fd1b5a714aceb08b8b1ffff0386adaa0098355ff2a9c7e603f8920ae78de1b2ac10d6559e3dbfefc59f5b986bd298d74bc1cbb709ff067"}],"ComponentSizeInKB":4500,"CompsigList":["firmware-hdd-8173816d98_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/CP071783.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071783.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071783.scexe"],"Name":"firmware-hdd-8173816d98_0HPD6-2.1_amd64.deb","SHA1Sum":"3cc121fb184d5a28e5e34fd587cc0cb41ff510e7","SHA256Sum":"94405ce7e7a5d15d303d91d6875f4d04cf045098a67d0b62f73fcb018c597a05","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b4db6fa551e4400dbd12068749","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a48-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"3eea26b59910ab1f40d486f6c66a633826243efd","SHA256Sum":"bcf70bfadbee2c97adabb13912487dbde64405bd46b40951565f3e27f6a56586","SHA512Sum":"2203eafc4ac865d515f4838dfa3ffe78e5719e427b959c7b92f7f746f798e7b8c69f0f973f0b8f814b1e82c38ab7befcd9fd68cf0322ba47564662fe17adba80"}],"ComponentSizeInKB":33233,"CompsigList":["firmware-system-a48-4.04_2026_04_02-1.1.x86_64_part1.compsig","firmware-system-a48-4.04_2026_04_02-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/A48_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/CP071585.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071585.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071585.scexe"],"Name":"firmware-system-a48-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"3eea26b59910ab1f40d486f6c66a633826243efd","SHA256Sum":"bcf70bfadbee2c97adabb13912487dbde64405bd46b40951565f3e27f6a56586","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_14a6f633fe8647418d63619090","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068764.exe","SHA1Sum":"661882dd7108534a10e81a247ba00c5e8d66a0c3","SHA256Sum":"4f9f1ebbe58cc133ca56a62c3e5cbd2d0269b17d1d27c0610496d27d70d41885","SHA512Sum":"29ea68c01f52de911adc127491fea5885f95d597a211cb90221d98646fb4f0a17215b282d3c184eff754dfea7c12edddb9278fa3a70dfe7dfaa626b27c6a00fd"}],"ComponentSizeInKB":3179,"CompsigList":["cp068764.compsig"],"FileList":["cp068764.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEE0HPD6.rel"],"Name":"cp068764.exe","SHA1Sum":"661882dd7108534a10e81a247ba00c5e8d66a0c3","SHA256Sum":"4f9f1ebbe58cc133ca56a62c3e5cbd2d0269b17d1d27c0610496d27d70d41885","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5388d296fb844a3388089e9558","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30525a575550","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30525a575551","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-30525a575552","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-30525a575556","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30525a575554","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30525a575641","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30525a575555","Version":"HPD1"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","SHA512Sum":"5dfb9b7aac876057e507009462efa93f99a2079dcd7dd7ee33eaeb20b89be75a667d4c5f100237f237e1d6e2a2c50777db757fd7fedfb139c97b4e84fc0e40a8"}],"ComponentSizeInKB":1131,"CompsigList":[],"FileList":["Kioxia_RM6_KARM6ALSHPD1.HPb","Kioxia_RM6_KARM6ALSHPD1.xml","payload.json"],"Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"TypeOfChange":"1","Version":"HPD1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO007680RZWUU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWVA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWUT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUP","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f078413ab6e4fb6aeab7cecca","SupportedDevices":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H08_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071472.exe","SHA1Sum":"fb689d1ee00881a7e885a68ea24654eb615ec46b","SHA256Sum":"9be753c3acb08a576d0df3b1aff592a3fe7153a851a44921e0748efdf459c8c6","SHA512Sum":"bbf19c26b6bdc802a0b5aebc03cd545c42616186c50966715c9ffd317d082eb0cad3bb103d9137ab83084f90185a8fb38ef0d39c7f3d7a22b8499ad182270571"}],"ComponentSizeInKB":11271,"CompsigList":["cp071472.compsig"],"FileList":["cp071472.xml","cpqsetup.exe","H08_3.66_04_01_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071472.exe","SHA1Sum":"fb689d1ee00881a7e885a68ea24654eb615ec46b","SHA256Sum":"9be753c3acb08a576d0df3b1aff592a3fe7153a851a44921e0748efdf459c8c6","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_31a3459f0819481db2e4106cdc","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE NV60100M 100Gb 2p Strg Offload Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101d1590037d","Version":"22.45.1020"}]},"Files":[{"Checksum":[{"Filename":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","SHA512Sum":"3ec2dd907ce7a48ff70649f04f7ffb97df0931da4d8299c2cf90096fac201ad147dbf05d7aecd2999f74716268457135e2ee5935243348d20769a92ea925f5e5"}],"ComponentSizeInKB":7548,"CompsigList":[],"FileList":["22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","22_45_1020-R8M41-63001_Ax_header.pldm.xml","payload.json"],"Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"TypeOfChange":"1","Version":"22.45.1020"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7319fd82a07c4804b3f42bdb8e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.rpm","SHA1Sum":"62464cd2f6c755cde05eb6374f3a0cbc70307974","SHA256Sum":"700b6a45deb3f05b431a2ee4f30bc6cb3be4908ef2f43f09e912aaad5263f83a","SHA512Sum":"e2562eb02ed7a98e46928fc664ee69f7ea64f43e174836d121589396d3d0a0a8a0aa89ad084f4bfc3349e77fbf2a50ee45866ff7eca13f5393751c32e16d2f44"}],"ComponentSizeInKB":5320,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.rpm","SHA1Sum":"62464cd2f6c755cde05eb6374f3a0cbc70307974","SHA256Sum":"700b6a45deb3f05b431a2ee4f30bc6cb3be4908ef2f43f09e912aaad5263f83a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20f29c5efa6444618ec3b6a83c","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.20"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"FileName":"ilo5_320.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.20"}]},"Files":[{"Checksum":[{"Filename":"firmware-ilo5-3.20-1.1.x86_64.rpm","SHA1Sum":"7fba458cb0ef86c0d84b58e7e7add64c92bf1d2d","SHA256Sum":"3a1771a357f9aca92f2bce771ff183a6474925e6a60b49b1027a7b29f1f348b4","SHA512Sum":"4eac7168a06f7411f4c556263b0ea02d01b6d3c2d5f9968d87b6efe305fd75acfdaa3b0af2b8ba757e37afbccc10c5471e5c5eae77abc67e5acee2a855c2d38b"}],"ComponentSizeInKB":33308,"CompsigList":["firmware-ilo5-3.20-1.1.x86_64_part1.compsig","firmware-ilo5-3.20-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/CP071576.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/ilo5_320.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071576.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071576.scexe"],"Name":"firmware-ilo5-3.20-1.1.x86_64.rpm","SHA1Sum":"7fba458cb0ef86c0d84b58e7e7add64c92bf1d2d","SHA256Sum":"3a1771a357f9aca92f2bce771ff183a6474925e6a60b49b1027a7b29f1f348b4","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_656fa1c66f174c26843a18f8cc","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","12.0","15.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.76 (05/28/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U48_3.76_05_28_2026.fwpkg","SHA1Sum":"ce7f5d2c99b363c6ec35c8d99507518022ca43fb","SHA256Sum":"71e12c75f53a99e21a04ace89bb7d06c98536e4a7c0c1ab8c9668894b70d9e0b","SHA512Sum":"345f5c8def4d9fecec9d1e1de53f54bf5593e1d087d0bfc973bcade34f911a9ee67f029dab1d46960036f1320a97471c4629084b922032153244d04714ca2635"}],"ComponentSizeInKB":16424,"CompsigList":[],"FileList":["payload.json","U48_3.76_05_28_2026.signed.flash","U48_3.76_05_28_2026.xml"],"Name":"U48_3.76_05_28_2026.fwpkg","SHA1Sum":"ce7f5d2c99b363c6ec35c8d99507518022ca43fb","SHA256Sum":"71e12c75f53a99e21a04ace89bb7d06c98536e4a7c0c1ab8c9668894b70d9e0b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd4d9e203f8d4cffad82241bc2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U48"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3438-304b59585051","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3936-304b59585141","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3130-3932-304b59585142","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","SHA1Sum":"f461ec6e0f8a64f10da8fd26cddc1fcd1c7913f5","SHA256Sum":"82cadf1c03809a3b5ec339fa89d12b19ac22fa4b968d0c5f64d79834310ca591","SHA512Sum":"4ed2a2c7770dc11b81b09d1024163a9c7b6da03440d36f398f9fb826f27e80fe8f3638ecca8ca331e831614800e5d6250855ad5bb98f18efd48a1e235c30b821"}],"ComponentSizeInKB":5620,"CompsigList":[],"FileList":["payload.json","SKHynix_PE90X0_KPE9010IHPK2.HPb","SKHynix_PE90X0_KPE9010IHPK2.xml"],"Name":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","SHA1Sum":"f461ec6e0f8a64f10da8fd26cddc1fcd1c7913f5","SHA256Sum":"82cadf1c03809a3b5ec339fa89d12b19ac22fa4b968d0c5f64d79834310ca591","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b59585051","562340a5-3052-3030-3936-304b59585141","562340a5-3052-3130-3932-304b59585142"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KYXPQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KYXQA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR001920KYXQB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ef508d000e044335b7e1498570","SupportedDevices":["562340a5-3052-3030-3438-304b59585051","562340a5-3052-3030-3936-304b59585141","562340a5-3052-3130-3932-304b59585142"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070933.zip","SHA1Sum":"c1cbdd428ff50ce7f688de63b9604aa6c5bef4ac","SHA256Sum":"f4beb7b2d3171a61275a7e418007cc5567791ebb37368706f551a92bb75ed658","SHA512Sum":"e9fb0c58e42ff40abef088a1d9a20ee328d92ed80abf1c20c7facc9377af713a224f432fbc507555e5e5baca553599bfe804e3dac28d459c12de7528ef0b7c85"}],"ComponentSizeInKB":20114,"CompsigList":["CP070933.compsig"],"FileList":["/CP070933_BUILD_6.data","/CP070933.vmexe64","/CP070933.vmfile","/CP070933_VMw.zip","/CP070933.xml","/payload.json","/CP070933_VMw.zip/index.xml","/CP070933_VMw.zip/vendor-index.xml","/CP070933_VMw.zip/metadata.zip","/CP070933_VMw.zip/vib20/CP070933/HPE_bootbank_CP070933_HPDB.6-8.0.0.20613240.vib","/CP070933_VMw.zip/metadata.zip/vendor-index.xml","/CP070933_VMw.zip/metadata.zip/vmware.xml","/CP070933_VMw.zip/metadata.zip/vibs/CP070933-1033139981878007841.xml","/CP070933_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070933_HPDB.6-8.0.0.20613240.xml"],"Name":"CP070933.zip","SHA1Sum":"c1cbdd428ff50ce7f688de63b9604aa6c5bef4ac","SHA256Sum":"f4beb7b2d3171a61275a7e418007cc5567791ebb37368706f551a92bb75ed658","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070933","Version":"HPDB.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e43213c0ddde4f4ea1e04d9faa","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50ZNV256G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV512G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV1T","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"}]},"Files":[{"Checksum":[{"Filename":"cp070452.exe","SHA1Sum":"d2e02b32dc5de3caf81a26fb208aa8850adb2fef","SHA256Sum":"21b4ffe7a85a3856be6da9def8b9cc3fed914816b0905844f42433999e538745","SHA512Sum":"da2acb2f66c44845cc3208a138438940ebda53a95b315c099cfa77ca9e612b0e61f305707f3535e4f90012d566accabc19bb717f60d4bc4946626ab992fbcd32"}],"ComponentSizeInKB":7457,"CompsigList":["cp070452.compsig"],"FileList":["AAGA4103.sig","cp070452.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"Name":"cp070452.exe","SHA1Sum":"d2e02b32dc5de3caf81a26fb208aa8850adb2fef","SHA256Sum":"21b4ffe7a85a3856be6da9def8b9cc3fed914816b0905844f42433999e538745","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AAGA4103"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50ZNV256G, KXG50ZNV512G and KXG50ZNV1T Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"KXG50ZNV256G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV512G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV1T","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d92e1c665e8f4e629035cb196f","SupportedDevices":["002340a5-584b-3547-305a-4e5632353647","002340a5-584b-3547-305a-4e5635313247","002340a5-0000-584b-4735-305a4e563154"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U41_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u41-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"7bb74ddf491d6550bbba0c5c230e5b2368c6b9a4","SHA256Sum":"c1ea49b59c137b98daf801cafd26e87b2a583beef1a92f51c9041289d8aa1f01","SHA512Sum":"467bc542f29fa5a246456186f3aac09dfd7bbc4bfaade70d05fd92fc30b7915ae311547a02d34de790e707637b674ae9cb0d5b329bc03c971522f26206b9d760"}],"ComponentSizeInKB":11395,"CompsigList":["firmware-system-u41-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/CP071421.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/U41_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071421.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071421.scexe"],"Name":"firmware-system-u41-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"7bb74ddf491d6550bbba0c5c230e5b2368c6b9a4","SHA256Sum":"c1ea49b59c137b98daf801cafd26e87b2a583beef1a92f51c9041289d8aa1f01","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9fddb9088fb6413e91942b3a1c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U38_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071405.exe","SHA1Sum":"76f8a7671f6787126d749086c40158b5fb5063b5","SHA256Sum":"388898575e02983a9007e6d4457cc6c10259ff382d951cee791678011cd2d8aa","SHA512Sum":"3b5de8f42d36ff85f4f525bbe0455fa5792d02b930c0ada7e74ff3747367f93e53387ace6e5dad34d55600ca806a222b841c5de7b408fc96a00872b1db0c42f3"}],"ComponentSizeInKB":11590,"CompsigList":["cp071405.compsig"],"FileList":["cp071405.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_3.66_04_01_2026.signed.flash"],"Name":"cp071405.exe","SHA1Sum":"76f8a7671f6787126d749086c40158b5fb5063b5","SHA256Sum":"388898575e02983a9007e6d4457cc6c10259ff382d951cee791678011cd2d8aa","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d18b4ccd6b745858864a1a5ee","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_UBM2_1.20_F.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"1.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM2_1.20_F.fwpkg","SHA1Sum":"db8184aeb99d025d5c3746b531b3c07c11dfc53a","SHA256Sum":"dd4a5f892598d44d89c68f4b3332cfbda9cdba8ce01771355529ace5ad9e4c5e","SHA512Sum":"11a0691f7f01a5de6016af2e0ff3da1666137aaa5c488387089a9df666c7785f38186777a5bb1567e941a9fc7a74813c15c2203cd73949c07f8f9e67e19271c2"}],"ComponentSizeInKB":63,"CompsigList":[],"FileList":["HPE_UBM2_1.20_F.HPb","HPE_UBM2_1.20_F.xml","payload.json"],"Name":"HPE_UBM2_1.20_F.fwpkg","SHA1Sum":"db8184aeb99d025d5c3746b531b3c07c11dfc53a","SHA256Sum":"dd4a5f892598d44d89c68f4b3332cfbda9cdba8ce01771355529ace5ad9e4c5e","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901502000000"],"TypeOfChange":"1","Version":"1.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM2PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03cdf815345f4efd94751eaefd","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U63","U58","U46","U46","A43","A43","A43","U50","I44","A42","U61","U60","U46","U68","U68","U71","U71"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"i40e-kmp-default-2.28.16_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"c2eece950968e790e71e94c468ea57dfb3c46884","SHA256Sum":"9663e8d3cd7d5a415eb1e1666ff5ea01f266fcb06cbdfdda033e0cbeb46a636d","SHA512Sum":"8b8b45c3f9a6c1fbbeab37432b3c8669c48e5ba650c838ca71141de42808c5781205b80757923cefef8113555010ef18224907e60e33ec97687fb8e67d74b333"}],"ComponentSizeInKB":520,"CompsigList":["i40e-kmp-default-2.28.16_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/i40e.ko","./usr/share/doc/packages/i40e-kmp-default","./usr/share/doc/packages/i40e-kmp-default/COPYING","./usr/share/doc/packages/i40e-kmp-default/README","./usr/share/man/man7/i40e.7.gz","./usr/share/pci.ids.d/pci.ids.i40e-kmp-2.28.16","./usr/share/smartupdate/i40e-kmp-default/component.xml"],"Name":"i40e-kmp-default-2.28.16_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"c2eece950968e790e71e94c468ea57dfb3c46884","SHA256Sum":"9663e8d3cd7d5a415eb1e1666ff5ea01f266fcb06cbdfdda033e0cbeb46a636d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdb806fec"],"TypeOfChange":"1","Version":"2.28.16-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a0fb6f1d399452f8a80435c62","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd_4.8.0-2167.4-ubuntu26_amd64.deb","SHA1Sum":"bff49c78f004a0e2ea88abe7c547afcaae307f88","SHA256Sum":"cd8bd9603158970d16b1dd57b287c60d1f5649b8fcd18fda70dc11dff2d02f83","SHA512Sum":"f7061b962fd35fcb68cd7f3577aaa94e9637adfa4cfb7a3784d19919defc9f46af25e0e8f157ca1d63ab497eff4a25172174bfba032c3ae0f47725af13b22f23"}],"ComponentSizeInKB":8951,"CompsigList":["amsd_4.8.0-2167.4-ubuntu26_amd64.compsig"],"FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"Name":"amsd_4.8.0-2167.4-ubuntu26_amd64.deb","SHA1Sum":"bff49c78f004a0e2ea88abe7c547afcaae307f88","SHA256Sum":"cd8bd9603158970d16b1dd57b287c60d1f5649b8fcd18fda70dc11dff2d02f83","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service for Ubuntu 26.04 LTS","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_98d698d912b041f08b0ef891d6","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","A40","U30","U32","I42","U38","U38","U34","I43","A42","A43","A41","A42","A43","A42","A43","U46","U46","A55","A56","A55","A56","U54","U54","U54","U63","U63","U59","U58","U58","I45","I44","U69","U69","U68","U68","U68","U62","U77","U71"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.deb","SHA1Sum":"be965a5ed17185cd1a755053defaf8e883e87b34","SHA256Sum":"0f312c64f7787f8f9372066bd0e595b0ac9c294bf41e92f1e6044a64f743dd69","SHA512Sum":"0ca3da9bb857c8c6a7fd5ee8b51d895473fac252881da7353519436ca66e4e48c8960fa8acd10cfcc8de2d78361b040b324bbcb8b4a98a1f51aa9de08c797c04"}],"ComponentSizeInKB":3508,"CompsigList":["firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/CP071751.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071751.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071751.scexe"],"Name":"firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.deb","SHA1Sum":"be965a5ed17185cd1a755053defaf8e883e87b34","SHA256Sum":"0f312c64f7787f8f9372066bd0e595b0ac9c294bf41e92f1e6044a64f743dd69","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_803b22d0f60d4e3c9d1127aab8","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070243.zip","SHA1Sum":"82acfd4220e26cdcf6b44b4b57b33483e398027b","SHA256Sum":"45ac91ed4b876363a43bddf644af67ed5b2bf90dfa24bd0a5c3049772223a471","SHA512Sum":"7d495233380b3d7bbd5780840b533f20608bf753be7278b4558486f6f547995eda6f772af443377c79337989542d25774684ef13f5c23bd8ccf0488c953f0046"}],"ComponentSizeInKB":244,"CompsigList":["cp070243.compsig"],"FileList":["/cp070243.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/vib20/ixgben/INT_bootbank_ixgben_1.23.3.0-1OEM.800.1.0.20613240.vib","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ixgben-2518073272967229593.xml","/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-ixgben_1.23.3.0-1OEM.800.1.0.20613240.xml"],"Name":"cp070243.zip","SHA1Sum":"82acfd4220e26cdcf6b44b4b57b33483e398027b","SHA256Sum":"45ac91ed4b876363a43bddf644af67ed5b2bf90dfa24bd0a5c3049772223a471","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"ixgben","Version":"1.23.3.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.23.3.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.23.3.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7bbe445fa974deea9403874ff","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A66","A66","U77","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072293.exe","SHA1Sum":"63b4f09772a1467aa054e7e5b303c769d630e0a3","SHA256Sum":"d3c0e822aafdac22b161f668f3d3128d49886a5875e5e87ca0e50621ed8f20ab","SHA512Sum":"e34e7c7717d9c2aa8012923e8108be6757fad618822328d3be380cf53be232aa00a7d8a20bab25b5a3060902bd94ce8fe3c9b2ef319348a043ff83da9e99e39c"}],"ComponentSizeInKB":584,"CompsigList":["cp072293.compsig"],"FileList":["cp072293.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp072293.exe","SHA1Sum":"63b4f09772a1467aa054e7e5b303c769d630e0a3","SHA256Sum":"d3c0e822aafdac22b161f668f3d3128d49886a5875e5e87ca0e50621ed8f20ab","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_84e5ca253cd54184b167df1077","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U36","U43","U41","U33","U44","A47","U40","U39","U45","U37","A46","U38","U38","U48","I43","I42","U46","U46","U47","U47","U50","I44","U61","U60","U56","A43","A42","A43","A42","A48","U50","U40","U39","U64","H10","H10","H08","H10","H08"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070944.zip","SHA1Sum":"769247ee17b9fbe3e7758e929ace4f85f61cd280","SHA256Sum":"413d0964f1ad4a301c9c6f5f83de003dfb3c646a27c28d9e51b1aa5fc71e0a46","SHA512Sum":"ff0f7e8cb3f229b3fb1ccee5350fbf118c7058953f88925b80ea4653ae19da8567273befb325e3b47aa15add3f78819e15bb6fbf08b1d2571a55ebd1fe201a94"}],"ComponentSizeInKB":18946,"CompsigList":["CP070944.compsig"],"FileList":["/CP070944_BUILD_4.data","/CP070944.vmexe64","/CP070944.vmfile","/CP070944_VMw.zip","/CP070944.xml","/payload.json","/CP070944_VMw.zip/index.xml","/CP070944_VMw.zip/vendor-index.xml","/CP070944_VMw.zip/metadata.zip","/CP070944_VMw.zip/vib20/CP070944/HPE_bootbank_CP070944_HPG6.4-8.0.0.20613240.vib","/CP070944_VMw.zip/metadata.zip/vendor-index.xml","/CP070944_VMw.zip/metadata.zip/vmware.xml","/CP070944_VMw.zip/metadata.zip/vibs/CP070944--5501498643801557585.xml","/CP070944_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070944_HPG6.4-8.0.0.20613240.xml"],"Name":"CP070944.zip","SHA1Sum":"769247ee17b9fbe3e7758e929ace4f85f61cd280","SHA256Sum":"413d0964f1ad4a301c9c6f5f83de003dfb3c646a27c28d9e51b1aa5fc71e0a46","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070944","Version":"HPG6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47742ac5bd55468d8b87a10d45","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f15900382","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f15900383","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"HPE_SR_Gen10_8.23_A.fwpkg","SHA1Sum":"0bbae64c779f1c3f5a1adbccdf4f23285292ffef","SHA256Sum":"71e9da6a6a8663c26e5a1376fdee476c7664f7a66cc5f27694ba58afba92eaf0","SHA512Sum":"8552a5e518756d5f8b9f7438453f8b842f94522ed4bff78183d9b1d6affab26517e2dc0af0ff9524ece0166834c042c02c7ce798202333dcc42f49c4c0c0effc"}],"ComponentSizeInKB":11835,"CompsigList":[],"FileList":["HPE_SR_Gen10_8.23_A.HPb","HPE_SR_Gen10_8.23_A.xml","payload.json"],"Name":"HPE_SR_Gen10_8.23_A.fwpkg","SHA1Sum":"0bbae64c779f1c3f5a1adbccdf4f23285292ffef","SHA256Sum":"71e9da6a6a8663c26e5a1376fdee476c7664f7a66cc5f27694ba58afba92eaf0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f15900383"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"MinimumActiveVersion":"5.61","Name":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"03831590","SWKeyExpectedPath":"firmware"},{"Name":"03821590","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"1100103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7b32c1640d704503b329228d12","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","10.0"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A56","A56","A55","A55","U58","U54","U54","U54","U63","U58","U58","U59","U63","U34","U34","A42","U46","U30","A42","U46","U32","A43","A43","A43","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","U39","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","U46","U57","U65","U65","U62","U64","U43","U44","U50","U71","U71","U68","U68","A66","A66","U68","U72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068941.zip","SHA1Sum":"88f7256b0628ee83e5f3025b8d92d8fd53240e71","SHA256Sum":"a490c9d5aab817b0173bb384d9ee300988ae61ab26d3300a0f5ad0dfde7d1199","SHA512Sum":"8739d86245e268df100f9700733e474e99ea423953e86c02873c32ee07782728e4c775bed5611021173a3fd0c6dd0ba4f98c6caa4c1f52fdbc63488b812e88ad"}],"ComponentSizeInKB":260,"CompsigList":["cp068941.compsig"],"FileList":["/cp068941.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vib20/i40en/INT_bootbank_i40en_2.11.1.0-1OEM.900.0.24755229.vib","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/i40en-824206042229324044.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.xml"],"Name":"cp068941.zip","SHA1Sum":"88f7256b0628ee83e5f3025b8d92d8fd53240e71","SHA256Sum":"a490c9d5aab817b0173bb384d9ee300988ae61ab26d3300a0f5ad0dfde7d1199","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"i40en","Version":"2.11.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d334abf4b041473783a6d9955d","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24fe569b72_0HPD6-2.1_amd64.deb","SHA1Sum":"b766059b0a7f25837e23cc50615c31e813cdada5","SHA256Sum":"3d511413a2fbad5404ed5a625d139b7b44affe66c6acdb53821f2cb71cffc0c3","SHA512Sum":"94a18550ee26cb05a8b20a8326cf37a42e5cdbce5a7b79b8372c19929d903ac1bd184289f0554fd2416d4da892f50f039ae32ccb1664395863f023f0a12ca67e"}],"ComponentSizeInKB":3474,"CompsigList":["firmware-hdd-24fe569b72_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/CP071704.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071704.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071704.scexe"],"Name":"firmware-hdd-24fe569b72_0HPD6-2.1_amd64.deb","SHA1Sum":"b766059b0a7f25837e23cc50615c31e813cdada5","SHA256Sum":"3d511413a2fbad5404ed5a625d139b7b44affe66c6acdb53821f2cb71cffc0c3","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c770bd228a124fa68b071f4769","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068639.exe","SHA1Sum":"886df1f2d9de7e06392c89fd6a95399413544354","SHA256Sum":"3963f7e2f3c2ea44dce9e2071c5d6d057a92bfc7e222bdf0bc4e61a3e5ddfdb4","SHA512Sum":"e9779bcd90c05727eacb2141c0407757e0622c5cddc8f6cde98c1b2b21c9a33120e64dc59a523cc52050e707aa2f2fd601fc967896a6b758efdd6e44dee7e360"}],"ComponentSizeInKB":3363,"CompsigList":["cp068639.compsig"],"FileList":["cp068639.xml","cpqsetup.exe","GPM1643ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068639.exe","SHA1Sum":"886df1f2d9de7e06392c89fd6a95399413544354","SHA256Sum":"3963f7e2f3c2ea44dce9e2071c5d6d057a92bfc7e222bdf0bc4e61a3e5ddfdb4","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_23d8ca08b6234a54bf8d875213","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_MR216i-p_Gen10P_52.36.3-6584_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.36.3-6584"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR216i-p_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"2918c7ecaa1a95a488493158969650eaabf9fcc5","SHA256Sum":"9793fff2c516148a72b3391316bc49b66252c43703e0c81a1b5abd5553908ea5","SHA512Sum":"235e8309b0abdec34349e978d8d9dd4075a3799f5e11ad8309ab9e99b3808ec720bf0ac3e51c1fe494ac924afdedbc1958a49ab7d179be6b4be91d41911609ac"}],"ComponentSizeInKB":7341,"CompsigList":[],"FileList":["HPE_MR216i-p_Gen10P_52.36.3-6584_A.HPb","HPE_MR216i-p_Gen10P_52.36.3-6584_A.xml","payload.json"],"Name":"HPE_MR216i-p_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"2918c7ecaa1a95a488493158969650eaabf9fcc5","SHA256Sum":"9793fff2c516148a72b3391316bc49b66252c43703e0c81a1b5abd5553908ea5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.36.3-6584"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc897941cfc4490d9a8525ea24","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071895.zip","SHA1Sum":"9e6dc9e9d3d95b884f2477d1736df0d5b8006139","SHA256Sum":"e2e26305d2a6f5bb42883645e79aaa08d49dd3420588b76feff98b54347529fa","SHA512Sum":"d55515cf8a5612eb0ac78fc187de2887668e82ac23e60736f485b0f24226aa0c2040427a3300ffce85580506f0d7c6a06956aeec6432a4b7d9530766ae3ed0f4"}],"ComponentSizeInKB":411,"CompsigList":["cp071895.compsig"],"FileList":["/cp071895.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip","/MIS_bootbank_smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/vib20/smartpqi/MIS_bootbank_smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/smartpqi-2527423866099698718.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.xml"],"Name":"cp071895.zip","SHA1Sum":"9e6dc9e9d3d95b884f2477d1736df0d5b8006139","SHA256Sum":"e2e26305d2a6f5bb42883645e79aaa08d49dd3420588b76feff98b54347529fa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"smartpqi","Version":"80.4902.0.103-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component).","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Microchip-smartpqi:80.4902.0.103-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:80.4902.0.103-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_728c9f02e41c4eda8aa424c034","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U32","U46","A43","A43","A43","A41","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","A66","U71","A66","U68","U72","U68","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068744.exe","SHA1Sum":"86b305503e55980414c2478bf2ba645ce4835a9f","SHA256Sum":"9babc0351bc59f0b988cff6f69350a2274f32c06efd0b759e07e5d6ea3979001","SHA512Sum":"c812314e42f79d5b2a4319af976a53aa6d74149ff82281827dfaa7520468443ef22393a50195be7734cd097c547eeaf86142f707071e191f3ff4e993e46d0c19"}],"ComponentSizeInKB":4434,"CompsigList":["cp068744.compsig"],"FileList":["cp068744.xml","cpqsetup.exe","HVLAeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068744.exe","SHA1Sum":"86b305503e55980414c2478bf2ba645ce4835a9f","SHA256Sum":"9babc0351bc59f0b988cff6f69350a2274f32c06efd0b759e07e5d6ea3979001","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6f7b50d5341b4904868164eb9b","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071001.exe","SHA1Sum":"0752fc25f37a79b27f10664e81df9dc5e8e78c99","SHA256Sum":"4a43d9b90f08a1fa42aed136d92761d9e124bf40166047f51e93be0667a712c2","SHA512Sum":"290887df7bb3a57a29b6d76cea187365e20ff1cf7e75cc2fd2ad4a827a2f345ac153477f7f72bf012d16632cb79a450bb5391e40a642a2a13e1b76a3cd723094"}],"ComponentSizeInKB":19285,"CompsigList":["cp071001.compsig"],"FileList":["ams.cab","ams.msi","cp071001.xml","cpqsetup.exe","install.xml","multisetup.dll","SmaInstall.cab","VC_redist.x64.exe"],"Name":"cp071001.exe","SHA1Sum":"0752fc25f37a79b27f10664e81df9dc5e8e78c99","SHA256Sum":"4a43d9b90f08a1fa42aed136d92761d9e124bf40166047f51e93be0667a712c2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"TypeOfChange":"1","Version":"2.80.0.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Agentless Management Service for Microsoft Windows x64","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"ams.exe","SWKeyExpectedPath":"%ProgramFiles%\\OEM\\AMS\\service"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07d881f6ee8c4d3d8e8ac1c712","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U41","U33","U40","U37","U38","U38","A41","U43","U44","A42","A43","U48","U31","U31","U39","U45","I43","I42","H09","U39","A42","A43","A43","A42","I44","U46","U46","U47","U47","U50","A47","A48","A46","U61","U60","U56","H08","H08","H10","U64","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"storcli_007.3604.0000.0000_all.deb","SHA1Sum":"c612152ba5f7763bb99e5d924d08015dfa4ce80f","SHA256Sum":"30f3e0d625670967ba96a8dd0c189f33c8e7e49472c8f60e60bff12b43b74be3","SHA512Sum":"523c3fd163425afd22404ac68d785be38e58c841cb1b532cfa93a62529b259f367e4363deb378efd1bfb09e1de9222b0a6bf688e18cf9625245b73cb47dee5e2"}],"ComponentSizeInKB":2123,"CompsigList":["storcli_007.3604.0000.0000_all.compsig"],"FileList":["./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"Name":"storcli_007.3604.0000.0000_all.deb","SHA1Sum":"c612152ba5f7763bb99e5d924d08015dfa4ce80f","SHA256Sum":"30f3e0d625670967ba96a8dd0c189f33c8e7e49472c8f60e60bff12b43b74be3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3604.0000.0000"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_51e4703baf5541a39b8cedc42c","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Video","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069739.exe","SHA1Sum":"c0d8e70cc76941d60df8314bdd9f164b6527c259","SHA256Sum":"044990fed406c368ad87b742fa1f26ef4647b1909c97c366922f6f3815d1e95b","SHA512Sum":"f1e1b6ba743822d78a00dcb0774be20dc5644674a7e194910bd20cc3669da66cca8ccc945e5455c2ec0e62bbcffc3f7213f611a30eb68e12beee2a87bb42fda4"}],"ComponentSizeInKB":1600,"CompsigList":["cp069739.compsig"],"FileList":["cp069739.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","mxg200eh.cat","MxG200eH.inf","MxG2hDO64.sys"],"Name":"cp069739.exe","SHA1Sum":"c0d8e70cc76941d60df8314bdd9f164b6527c259","SHA256Sum":"044990fed406c368ad87b742fa1f26ef4647b1909c97c366922f6f3815d1e95b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.268"}],"InstallationDependency":{},"Name":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c4ee434232a45659b386e450c","SupportedDevices":["a6b1a447-382a-5a4f-102b-0538159000e4","a6b1a447-382a-5a4f-102b-05381590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399","10.0.20317.25398","10.0.17600.18999","10.0","10.0"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U61","U60","U56","A42","A43","A42","A43","H10","H08","H08","H10","H10","A48","U50","U39","U40","I41","U36","U43","U45","U37","U38","U38","U64","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U46_2.64_04_01_2026.fwpkg","SHA1Sum":"ea70d409c026b66149b7c69bdbd24321d34dfede","SHA256Sum":"a740a7ecb7cee8ee56dd7a5f5e37bf2d9c0872745add524135285d77ca753c50","SHA512Sum":"27353a44fb95499f00addbdcda81fabb4a001b7fcbc075e55f4281748142ead3b057d49883c57b7e3d4d0386a245cbded2f2cc40200529091830edc677614acc"}],"ComponentSizeInKB":32818,"CompsigList":[],"FileList":["payload.json","U46_2.64_04_01_2026.signed.flash","U46_2.64_04_01_2026.xml"],"Name":"U46_2.64_04_01_2026.fwpkg","SHA1Sum":"ea70d409c026b66149b7c69bdbd24321d34dfede","SHA256Sum":"a740a7ecb7cee8ee56dd7a5f5e37bf2d9c0872745add524135285d77ca753c50","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ca20d6677dcd439886ace50747","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"e42e9ca3a56752b35290c54f5c99d28f2ea8456c","SHA256Sum":"a8c79f0fbd466c17bed0faba8683185c4d06eea3c865abac1dd221a6361443c7","SHA512Sum":"b90e09bf70a90280b7b69576037e6395bc33ed1cc3a57b06847fa7c0a8d550c10906329c4511581ec01139fadc4dec175a6da7f8079f8ba163e3f2065f895a96"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"e42e9ca3a56752b35290c54f5c99d28f2ea8456c","SHA256Sum":"a8c79f0fbd466c17bed0faba8683185c4d06eea3c865abac1dd221a6361443c7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900345"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7dbaac55fac4085ac7ee79631","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900345"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071253.exe","SHA1Sum":"cbd91c537cacbf3c6c5eb2981fe111e4a77d2b18","SHA256Sum":"1986237b3e15a5b9c307dccf07308f00efbb206810d5c0fc11a6f85898d8fa79","SHA512Sum":"2485b52af0297595d685a33abc796de118791c170c4134e1c403edef066073fd4fbaac3e3bbcba7c214a271abfbfbcd5ccd224fb98cdeba769be68b173e95c35"}],"ComponentSizeInKB":1722,"CompsigList":["cp071253.compsig"],"FileList":["cp071253.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp071253.exe","SHA1Sum":"cbd91c537cacbf3c6c5eb2981fe111e4a77d2b18","SHA256Sum":"1986237b3e15a5b9c307dccf07308f00efbb206810d5c0fc11a6f85898d8fa79","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a1001a256ded40b9b7c42a5bb4","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000_6.00-3.1_amd64.deb","SHA1Sum":"9e43c92756a4ce261616d1f24b64d039bc5cdbee","SHA256Sum":"32ad158f9e25babd750b58503f39b36a1b9818bd9775377d7a337f2843174ff5","SHA512Sum":"a8066c3938f41e7c084bee05bf1eff1bb82ce1783bf3dc6060bbdde9ad8a95345ca4df660dc41d949f958885a68591b0f6cf5d8eb02fa6043c5448ebf337c4be"}],"ComponentSizeInKB":2316,"CompsigList":["firmware-d3000_6.00-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/CP072185.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072185.scexe","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072185.scexe"],"Name":"firmware-d3000_6.00-3.1_amd64.deb","SHA1Sum":"9e43c92756a4ce261616d1f24b64d039bc5cdbee","SHA256Sum":"32ad158f9e25babd750b58503f39b36a1b9818bd9775377d7a337f2843174ff5","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1706b7d577f04dafbe67fa8bad","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware"},{"DelayAfterInstallSec":0,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"cp069587.exe","SHA1Sum":"b3167040d37f08dfe6fa35195212d97d19aac8c3","SHA256Sum":"fe8fec7dec1c06db9214fdeededda003ca8427648ea2258bf6bacfa6b8b5d154","SHA512Sum":"38117a8b93bd11fb2f1bf2ffae7dfe6ff671bd47e7151f8df9149003c1300533ee5b83fe5dd969962bc9b7a2044bb93de4bd8484c7b7181bb57da85d280b76e9"}],"ComponentSizeInKB":6757,"CompsigList":["cp069587.compsig"],"FileList":["cp051154.compsig","cp051154.zip","cp051155.compsig","cp051155.zip","cp069587.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069587.exe","SHA1Sum":"b3167040d37f08dfe6fa35195212d97d19aac8c3","SHA256Sum":"fe8fec7dec1c06db9214fdeededda003ca8427648ea2258bf6bacfa6b8b5d154","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_08a87fb5ad0840a6b85d1093a8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U30","U32","U31","U31","U41","U33","U39","I43","I42","U34","U40","U37","U38","U38","U45","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069726.exe","SHA1Sum":"7bea197f62d9237ad3698c56654b63ff50f8f820","SHA256Sum":"02d38376c18d1911600c94d899e1bf0e79e6235b53ad5c906374ca7f1fdcf315","SHA512Sum":"5fd4d0f9b25b60b0dbc302194225feddb27e103d32195d237b023836a27d2bb717e35f19b624096f36abc87c9666855ff9fd10caac60d99afde61ecaa15b14f3"}],"ComponentSizeInKB":589,"CompsigList":["cp069726.compsig"],"FileList":["cp069726.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp069726.exe","SHA1Sum":"7bea197f62d9237ad3698c56654b63ff50f8f820","SHA256Sum":"02d38376c18d1911600c94d899e1bf0e79e6235b53ad5c906374ca7f1fdcf315","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.2.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\nechesasr.inf_amd64_4549a532e2f9c151"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_154a444b0711470cab8f62e39a","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U46","U46","U47","U47","U50","I44","H08","H08","H10","A48","U39","U40","U50","H10","H10","U60","U61","U56","A43","A43","A42","A42","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"},{"DelayAfterInstallSec":180,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"cp072203.exe","SHA1Sum":"8835a6853449f93e42a230f007dda8efd2f2c33b","SHA256Sum":"118d94b30b10478d4425139b0fae4e07077eb217a313d1c5919630f6f8d8ab50","SHA512Sum":"27015cd84e50f1c21d85419f9f21a224754116ed1d6b39fb1eeb090cfb21a4c41b90bee0c0593572d2c7f0bc76c6bcf09278a5627426afc19da0ef047d431c76"}],"ComponentSizeInKB":14876,"CompsigList":["cp072203.compsig"],"FileList":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","Config.xml","cp072203.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"Name":"cp072203.exe","SHA1Sum":"8835a6853449f93e42a230f007dda8efd2f2c33b","SHA256Sum":"118d94b30b10478d4425139b0fae4e07077eb217a313d1c5919630f6f8d8ab50","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a8a00d6438540cbb1ccbdb143","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ice-kmp-default-2.4.5_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"c798922000e38b05e146533f7093440a68f804de","SHA256Sum":"ef9899f6008a878107fa03a86c586f3f1b4a92c42c4bcef5d3741957e518aeb8","SHA512Sum":"3f31b961ac3b84566c7681bb57aa48ccaea0530239b72e241053f77cecf45a0a23004bcc2e6efd37a884939135d26d629b87ab9d0c77db33736d985283953ebc"}],"ComponentSizeInKB":1107,"CompsigList":["ice-kmp-default-2.4.5_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/ice","./lib/modules/6.4.0-150600.21-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.4.5_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"c798922000e38b05e146533f7093440a68f804de","SHA256Sum":"ef9899f6008a878107fa03a86c586f3f1b4a92c42c4bcef5d3741957e518aeb8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.4.5-1"},{"Checksum":[{"Filename":"ice-kmp-default-2.4.5_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"a2088e4772be3331cce43cd054d6b7e15842182e","SHA256Sum":"ea3e557f54c8a2bc77f213562cdaa2484cd5319b3af20d69837935c361e694a6","SHA512Sum":"57e6faf9712703cfac72ff5ec9b0e807365c279fc104040aa74638d452a28e27ff9fa03d026985423891ad4daebfbb0893d9d8de3011be26f055d621f21b63f3"}],"ComponentSizeInKB":1108,"CompsigList":["ice-kmp-default-2.4.5_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/ice","./lib/modules/6.4.0-150700.51-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.4.5_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"a2088e4772be3331cce43cd054d6b7e15842182e","SHA256Sum":"ea3e557f54c8a2bc77f213562cdaa2484cd5319b3af20d69837935c361e694a6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.4.5-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2dfd583f40e541e18380fc93eb","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068733.exe","SHA1Sum":"61b1db87c89a90c0f9feb0a020b7dd0ea0801f05","SHA256Sum":"ee6c61a61e9be69bf9651f9cf8b923af5c3e73f66ca98dc70eba832e0c8b91c4","SHA512Sum":"f89555e03df4e0576386cbc15d56111e29078258af79268eef5fecc8bcc8060a85a93de43252988f1cf87f68d3a7ef0d65c1a8ff6524b29c2d5af20798ba9f87"}],"ComponentSizeInKB":4060,"CompsigList":["cp068733.compsig"],"FileList":["cp068733.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSTG1.rel"],"Name":"cp068733.exe","SHA1Sum":"61b1db87c89a90c0f9feb0a020b7dd0ea0801f05","SHA256Sum":"ee6c61a61e9be69bf9651f9cf8b923af5c3e73f66ca98dc70eba832e0c8b91c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f4ad092bde7c4e34aa17c38fe5","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072015.exe","SHA1Sum":"36f7623b8a3d3a39eaf71d40fe6818450ba9b4be","SHA256Sum":"90f58d5eb030cebc51fb927c78ffad26b7e2e47513141d3ea47a2d223ead21d2","SHA512Sum":"f9fe215c5504ad749ae882de011d49f32989efcee3bf261564901c5a37659d1a32f0f201a1d3461f2fe551453c374e833c60c269cb0d00b264580ee1067b5026"}],"ComponentSizeInKB":17738,"CompsigList":["cp072015.compsig"],"FileList":["A41_3.80_05_28_2026.signed.flash","cp072015.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072015.exe","SHA1Sum":"36f7623b8a3d3a39eaf71d40fe6818450ba9b4be","SHA256Sum":"90f58d5eb030cebc51fb927c78ffad26b7e2e47513141d3ea47a2d223ead21d2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dc36418e9a5c444ea31a54d413","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957414A4142HC.fwpkg","SHA1Sum":"8e606d02ae518178f69a80b617d8a11b10820a57","SHA256Sum":"0618f7f55693d5b2f6bbc926ecf2e5fed82418f6a410086112568b3ddf056ad0","SHA512Sum":"60cc46330a2c01fa99cbcd6ce5f7e0332793c884eba6711d10012ba8b381f6cf4049188a2ea61618461b917903dcd1dfa750e745bdc73e11158aab236474a754"}],"ComponentSizeInKB":1364,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957414A4142HC.HPb","BCM237.1.148.0_BCM957414A4142HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957414A4142HC.fwpkg","SHA1Sum":"8e606d02ae518178f69a80b617d8a11b10820a57","SHA256Sum":"0618f7f55693d5b2f6bbc926ecf2e5fed82418f6a410086112568b3ddf056ad0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57414 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57414_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_32e17b740fe14cc4a7e3692a88","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b58505256","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58505452","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58505454","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58505455","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b58505255","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b5850544e","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58505450","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58505451","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","SHA512Sum":"4034ddbc8681e09a856c8a3c6621485402230c8f8fd86bd48f92fdab70b6a8d2a95eb6166de6bd5e2647c2644fd4bfe610b1f57abb85b2711f82ab26adc761de"}],"ComponentSizeInKB":6114,"CompsigList":[],"FileList":["payload.json","SKHynix_PE81X0_KPE81X0AHPK2.HPb","SKHynix_PE81X0_KPE81X0AHPK2.xml"],"Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800KXPRV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXPTR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPTT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPTU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXPRU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXPTN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXPTP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXPTQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3ac2dd86a7d4e9aa334041028","SupportedDevices":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070843.zip","SHA1Sum":"043932c26c7d96accc31e39b8d17549ca639a9c9","SHA256Sum":"1f7ed0cd4fadad9adef2273e2d0737af00c3774272c505365208cdb3c2f98ec2","SHA512Sum":"0cc65d6cdaaabca2c2f3b5830db9184b08efbadfa8c966f8ddf7dfd8736ab455d81a9131e55e65a3814c476b8553069b7ad32e4ee9e820b38679a27d099b39f2"}],"ComponentSizeInKB":1486,"CompsigList":["cp070843.compsig"],"FileList":["/cp070843.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp070843.zip","SHA1Sum":"043932c26c7d96accc31e39b8d17549ca639a9c9","SHA256Sum":"1f7ed0cd4fadad9adef2273e2d0737af00c3774272c505365208cdb3c2f98ec2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7c18c1bccaff4d8ca61e5a5c02","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e0171a2936-HPG6-1.1.x86_64.rpm","SHA1Sum":"b925437ae57b1bc57647d3c8e16f306fe2dde516","SHA256Sum":"b1fe34857f491dbd3daca844ac3cc8d09838b0fafe6250e7fc9e6f248b63fa71","SHA512Sum":"329585d30bd8535bcba133b6dba6695287af83896ab46b16c2b58660b801429dec98cdaf7621f01ed4521948b9bea5bd2bdf9e17de201f6563456bbed864ed5d"}],"ComponentSizeInKB":5862,"CompsigList":["firmware-hdd-e0171a2936-HPG6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/CP070087.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/TAMG09acHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070087.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070087.scexe"],"Name":"firmware-hdd-e0171a2936-HPG6-1.1.x86_64.rpm","SHA1Sum":"b925437ae57b1bc57647d3c8e16f306fe2dde516","SHA256Sum":"b1fe34857f491dbd3daca844ac3cc8d09838b0fafe6250e7fc9e6f248b63fa71","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ed6630baf8aa499f80b331e47d","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070093.zip","SHA1Sum":"cfb6660b9f02412edab0bec8e72292839f11f8a1","SHA256Sum":"08078a87c65856307062d444c560312663dbbbdfb7c8ee3c94f1ca0a726a8009","SHA512Sum":"8fa36e96b0c032d1be04c15e16bdc98a55cdf20e9e62e72254297baaf0bda8a565ef1145b78bab11d42fd63a680b01514eb90f82b023c2051852b1547dcb0d66"}],"ComponentSizeInKB":19390,"CompsigList":["CP070093.compsig"],"FileList":["/CP070093_BUILD_6.data","/CP070093.vmexe64","/CP070093.vmfile","/CP070093_VMw.zip","/CP070093.xml","/payload.json","/CP070093_VMw.zip/index.xml","/CP070093_VMw.zip/vendor-index.xml","/CP070093_VMw.zip/metadata.zip","/CP070093_VMw.zip/vib20/CP070093/HPE_bootbank_CP070093_HPG6.6-8.0.0.20613240.vib","/CP070093_VMw.zip/metadata.zip/vendor-index.xml","/CP070093_VMw.zip/metadata.zip/vmware.xml","/CP070093_VMw.zip/metadata.zip/vibs/CP070093--8340103372554506873.xml","/CP070093_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070093_HPG6.6-8.0.0.20613240.xml"],"Name":"CP070093.zip","SHA1Sum":"cfb6660b9f02412edab0bec8e72292839f11f8a1","SHA256Sum":"08078a87c65856307062d444c560312663dbbbdfb7c8ee3c94f1ca0a726a8009","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070093","Version":"HPG6.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_56ae8d8bef5349878a95da4b3a","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.rpm","SHA1Sum":"f2216e80c587a72d626faca9b632c02c235ba1ee","SHA256Sum":"05fa5081d735141345f7766c3db85e35be9bad5a7885113dc7fef414a8fd6c23","SHA512Sum":"8b6e48a69ba3b68313dfe7d196664b71e6f8c6c5bf9aba666fd1f19c308a9b53652122afab30bc1d3a4066888032e19b150ebc3c43f9f1b04c68f90842874be5"}],"ComponentSizeInKB":78,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/mst_pci.ko","./lib/modules/6.4.0-150700.51-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.rpm","SHA1Sum":"f2216e80c587a72d626faca9b632c02c235ba1ee","SHA256Sum":"05fa5081d735141345f7766c3db85e35be9bad5a7885113dc7fef414a8fd6c23","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.sles15sp7.x86_64.rpm","SHA1Sum":"d8850582725d58314b8ab0cf9a1f79ca0a54282e","SHA256Sum":"03643b11dfd739c816e75c3c10ea58bb00eced814ba190c1cab04f333efb4314","SHA512Sum":"40be9ad533e809323e0f8e8dd95b8bd1dcd9ac8dc296d05e3f048ae285780b454a93de0539a015ec7f52b1bfb1b649f3b320fae915327386e512bb0336176cf2"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles15sp7.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles15sp7.x86_64.rpm","SHA1Sum":"d8850582725d58314b8ab0cf9a1f79ca0a54282e","SHA256Sum":"03643b11dfd739c816e75c3c10ea58bb00eced814ba190c1cab04f333efb4314","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP7 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_53f9c4daa268415e9a62a28018","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssaducli-6.65-9.0.x86_64.rpm","SHA1Sum":"4156d8be76e28e7cf4713c882bf4595dfd8c8b85","SHA256Sum":"328bcff7be9369cf60f8c6776f468ee8e677a0dfb08681731d4f008ea30c496a","SHA512Sum":"879883eafc01705e143dcd1107298df370b88f5d002dab47edf0d99c8c6f87080137966745f381a2388de837804ea64ee8c48b2658ff6e3c3a98916c214bd016"}],"ComponentSizeInKB":3586,"CompsigList":["ssaducli-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"Name":"ssaducli-6.65-9.0.x86_64.rpm","SHA1Sum":"4156d8be76e28e7cf4713c882bf4595dfd8c8b85","SHA256Sum":"328bcff7be9369cf60f8c6776f468ee8e677a0dfb08681731d4f008ea30c496a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c5049f2c88a84b789bbbbc8650","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","I44","U63","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","U19","Carbondale14","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","SHA1Sum":"6afefcc2508d6b8b6d11f4c4fd8507b2d48a43f5","SHA256Sum":"78c72c76bcd1da4096a415e955e2e2550e96900ccfb86a0c79e847af37bf9d42","SHA512Sum":"5924fb60b706fe97ea9d2b397ff2f9600be06cce8b5967e8ec938784c861c648edc030b8ea8d2b9f5d1d07949c523331a4d49575963ebc2e0051b0f14c9bc091"}],"ComponentSizeInKB":6254,"CompsigList":["firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/CP068927.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068927.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068927.scexe"],"Name":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","SHA1Sum":"6afefcc2508d6b8b6d11f4c4fd8507b2d48a43f5","SHA256Sum":"78c72c76bcd1da4096a415e955e2e2550e96900ccfb86a0c79e847af37bf9d42","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2bbb424bfdf4cb1a0025efc3d","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071351.exe","SHA1Sum":"45c6a8c50043c26501edd826d71920f4d62c997a","SHA256Sum":"1ce11489ad9355786e48800f57f30af0bd61993d952e120255bf70515b772fce","SHA512Sum":"f4a080758a61bbe0506685bf7429c3a38fcaa5a3446893c39a5d689faac0dcea19955fb26c85c0f1d57d189a5ea29dba382aab24f915575809d6e212d613c82f"}],"ComponentSizeInKB":17041,"CompsigList":["cp071351.compsig"],"FileList":["cp071351.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U64_2.64_04_01_2026.signed.flash"],"Name":"cp071351.exe","SHA1Sum":"45c6a8c50043c26501edd826d71920f4d62c997a","SHA256Sum":"1ce11489ad9355786e48800f57f30af0bd61993d952e120255bf70515b772fce","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d677932981e34b0f83f6fc405c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"CP071677.zip","SHA1Sum":"e07b4aa080ea3ba21cf7b97842dc834f99127e26","SHA256Sum":"12e1fb42b8f72bb9f7f2cbe14edcdd158d6df24c60839c0834fe81eacfb47429","SHA512Sum":"e539172aec80c99d79b7c3112e10913f12f1e9c43480e31c6cde6fcd7dcd89816dd36dd78b853a54306d8cec5f1ba22c03965f64da0808a5bcf59cfa12740fd8"}],"ComponentSizeInKB":30171,"CompsigList":["CP071677.compsig"],"FileList":["/CP071677.xml","/CP071677_VMw.zip","/payload.json","/CP071677.vmexe64","/CP071677.vmfile","/CP071677_VMw.zip/index.xml","/CP071677_VMw.zip/vendor-index.xml","/CP071677_VMw.zip/metadata.zip","/CP071677_VMw.zip/vib20/CP071677/HPE_bootbank_CP071677_1.0.0-8.0.0.21495797.vib","/CP071677_VMw.zip/metadata.zip/vendor-index.xml","/CP071677_VMw.zip/metadata.zip/vmware.xml","/CP071677_VMw.zip/metadata.zip/vibs/CP071677-7005355894148604731.xml","/CP071677_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071677_1.0.0-8.0.0.21495797.xml"],"Name":"CP071677.zip","SHA1Sum":"e07b4aa080ea3ba21cf7b97842dc834f99127e26","SHA256Sum":"12e1fb42b8f72bb9f7f2cbe14edcdd158d6df24c60839c0834fe81eacfb47429","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.10","VibList":[{"Name":"CP071677","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_db5ae8dbfb694cc99c9b73d4be","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-020fc874ad_0HPD3-2.1_amd64.deb","SHA1Sum":"3d8669f8bf7eb71a5998c05c4709831027c74ea9","SHA256Sum":"d756556c961dcb2041c9592dd3c46e13c0d83e47aec0f149c90ab5ecba16c5dd","SHA512Sum":"99baee857886f8d1e6ac3d05cb1bd5449e68ac8bc33a68fe16e4787ab78e2cfb0f1652df07ca5f8dc222a5d24189ff2e563b7807242240e7656bb9fcde89ced6"}],"ComponentSizeInKB":4509,"CompsigList":["firmware-hdd-020fc874ad_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/CP071801.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071801.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071801.scexe"],"Name":"firmware-hdd-020fc874ad_0HPD3-2.1_amd64.deb","SHA1Sum":"3d8669f8bf7eb71a5998c05c4709831027c74ea9","SHA256Sum":"d756556c961dcb2041c9592dd3c46e13c0d83e47aec0f149c90ab5ecba16c5dd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7183100acd934e559d8a2b05c5","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U60_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071344.exe","SHA1Sum":"d0a1727b34831871a4a0c08722c32629e6ad7b15","SHA256Sum":"6decf3f6555ec409590524abc93dc2b48327d784a437c62bede9fde418df22b4","SHA512Sum":"5555425631ca8dcf6bda14cd9b1b1222cc6d8691f1d6fd6e0c8d4ca95fd162868120447ab693ee1e02fcd8c9a756e3082d5879d31307c3198ede4b89101fcf5d"}],"ComponentSizeInKB":17044,"CompsigList":["cp071344.compsig"],"FileList":["cp071344.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U60_2.64_04_01_2026.signed.flash"],"Name":"cp071344.exe","SHA1Sum":"d0a1727b34831871a4a0c08722c32629e6ad7b15","SHA256Sum":"6decf3f6555ec409590524abc93dc2b48327d784a437c62bede9fde418df22b4","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54074ae48d8743788dc5726980","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067924.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"cp069634.exe","SHA1Sum":"8b02105d8ca4543b7140bf6000e32cdb5492f45a","SHA256Sum":"e7052da269aa0179e0b14028a97a106aa23cbe9004b998061a8064b0de38f8ef","SHA512Sum":"312acbfaf813328ea9c1f2d1b0a2da1bd6f33bd70b74443eb6e84f31d5fc4a6fe59946b7b74b8d89c6e38076e8095a7581d007c83b7142f409b82f7a3da39bc6"}],"ComponentSizeInKB":2587,"CompsigList":["cp069634.compsig"],"FileList":["cp067924.compsig","cp067924.zip","cp069634.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069634.exe","SHA1Sum":"8b02105d8ca4543b7140bf6000e32cdb5492f45a","SHA256Sum":"e7052da269aa0179e0b14028a97a106aa23cbe9004b998061a8064b0de38f8ef","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa5190582aad429fb4ad708a9c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U44","U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A46_4.04_04_02_2026.fwpkg","SHA1Sum":"f6eed4c076d70b9f0977f437e600fd19656ed8e5","SHA256Sum":"a03866150b5f927f3f11a58c5582d4cfbeea2b9eb977389ce65c445ec39cccb9","SHA512Sum":"7a3d890ac3026b7e17b2926eab3e6bc18f979310d5c4932997df4389da2a59ac7509026ca86f4a99daf2b42de5e82433229e15d09691baedd98947dfcdf6c84c"}],"ComponentSizeInKB":32810,"CompsigList":[],"FileList":["A46_4.04_04_02_2026.signed.flash","A46_4.04_04_02_2026.xml","payload.json"],"Name":"A46_4.04_04_02_2026.fwpkg","SHA1Sum":"f6eed4c076d70b9f0977f437e600fd19656ed8e5","SHA256Sum":"a03866150b5f927f3f11a58c5582d4cfbeea2b9eb977389ce65c445ec39cccb9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d4b6d71390d64a54b23a3a5adc","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070846.zip","SHA1Sum":"744f21b9a12f17deaa2c9f89fe29da860f5c5fcc","SHA256Sum":"3bd9b2167e9f7f414d1adb607d46e0e32eef2714abf241ea633632c25f1dae94","SHA512Sum":"074be49c32867591ea9cdc9cd0a1d221fef422f130e2e51efd218561d311fe75e46db2725b0ea953421885d4c55af75b9776e3df94a698caab46f48d7c825d51"}],"ComponentSizeInKB":119,"CompsigList":["cp070846.compsig"],"FileList":["/cp070846.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vib20/igbn/INT_bootbank_igbn_1.13.2.0-1OEM.900.0.24580437.vib","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vibs/igbn-831206253632276349.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.xml"],"Name":"cp070846.zip","SHA1Sum":"744f21b9a12f17deaa2c9f89fe29da860f5c5fcc","SHA256Sum":"3bd9b2167e9f7f414d1adb607d46e0e32eef2714abf241ea633632c25f1dae94","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"igbn","Version":"1.13.2.0-1OEM.900.0.24580437"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_69e604474754449c9774e704fe","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"cp068641.exe","SHA1Sum":"b0bb64448539df7575860edd075a005ac073f70d","SHA256Sum":"349ffe2cf282ec59c44ce0fcaf4d08087791ba0a51622fefe7b76dd7ed594836","SHA512Sum":"9ad7cd9b8e9cb21a7e735d80e18abcd20662d2f9bce8a9a822507780888ebedc9aebed0dc447cd16bca9cbaa084339aa89f016373488bf4ad1cc4eb629c1a9d1"}],"ComponentSizeInKB":5359,"CompsigList":["cp068641.compsig"],"FileList":["cp068641.xml","cpqsetup.exe","GPM173XAHPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068641.exe","SHA1Sum":"b0bb64448539df7575860edd075a005ac073f70d","SHA256Sum":"349ffe2cf282ec59c44ce0fcaf4d08087791ba0a51622fefe7b76dd7ed594836","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_244a6149e7704ded8c87c64b7b","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070922.zip","SHA1Sum":"f58facdd9a2de598a33895b4c487d513e8cf63e5","SHA256Sum":"4513fefedba1b162edcdebb23968b4deb14039f20fde78b76d8fd80d50ca46b3","SHA512Sum":"5dca17389cfac8099fa4229e64ab642068a0f22e73bc69a5b3b270de11f4317a62255a073ea9bf1a59d93cbd86b1fa4f7c705b4d4f1734b9883b582a2882d021"}],"ComponentSizeInKB":20944,"CompsigList":["CP070922.compsig"],"FileList":["/CP070922_BUILD_7.data","/CP070922.vmexe64","/CP070922.vmfile","/CP070922_VMw.zip","/CP070922.xml","/payload.json","/CP070922_VMw.zip/index.xml","/CP070922_VMw.zip/vendor-index.xml","/CP070922_VMw.zip/metadata.zip","/CP070922_VMw.zip/vib20/CP070922/HPE_bootbank_CP070922_HPG1.7-8.0.0.20613240.vib","/CP070922_VMw.zip/metadata.zip/vendor-index.xml","/CP070922_VMw.zip/metadata.zip/vmware.xml","/CP070922_VMw.zip/metadata.zip/vibs/CP070922-8853817900184222612.xml","/CP070922_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070922_HPG1.7-8.0.0.20613240.xml"],"Name":"CP070922.zip","SHA1Sum":"f58facdd9a2de598a33895b4c487d513e8cf63e5","SHA256Sum":"4513fefedba1b162edcdebb23968b4deb14039f20fde78b76d8fd80d50ca46b3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070922","Version":"HPG1.7-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives.","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8030605e03cb42dfbd8c04f471","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"cp071675.exe","SHA1Sum":"69ed7fb3785c5f69e278fe9a64612686cb0ed184","SHA256Sum":"554315366d12ebbdee951e321f669db0138a546574db5d8669bbf29e5a13c8a5","SHA512Sum":"278549f391643facd84ad54dc7f9512b263004c641b2547b1e6156045f29a6f6375437b714c05e9a5ee6f20e70b149d2c038ad927ce04aa390af9efd30152725"}],"ComponentSizeInKB":28675,"CompsigList":["cp071675.compsig"],"FileList":["cp071675.xml","cpqsetup.exe","fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp071675.exe","SHA1Sum":"69ed7fb3785c5f69e278fe9a64612686cb0ed184","SHA256Sum":"554315366d12ebbdee951e321f669db0138a546574db5d8669bbf29e5a13c8a5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.0.16"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3f05fb25d0d441bd85fe8a4c9a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067923.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"cp069639.exe","SHA1Sum":"f83d771619998cbbffc9b0f1db4c16e71d908d8b","SHA256Sum":"0376f3e0229b4158701c8bfb08bef8efe9e5d7e0e5a83e120327a0ed8a26b413","SHA512Sum":"01a1d322d3f728193d312a6e61a428b6a7916dd8f507ebe09e826fd69c789ae5dd95d891760625fe5002f3ba2bfbc1118cca999358711bac053befad4fe34a78"}],"ComponentSizeInKB":2585,"CompsigList":["cp069639.compsig"],"FileList":["cp067923.compsig","cp067923.zip","cp069639.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069639.exe","SHA1Sum":"f83d771619998cbbffc9b0f1db4c16e71d908d8b","SHA256Sum":"0376f3e0229b4158701c8bfb08bef8efe9e5d7e0e5a83e120327a0ed8a26b413","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_947c2aba9257407c8bad37d9c2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U48"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070929.zip","SHA1Sum":"ca87fedf08ae3adb9cf3401252db8b436ade86b7","SHA256Sum":"9bd3eb9a1f9dfd0c0ea5a5d6612e7c7b9bda6674dcac3c32a5891f3b276ca5c3","SHA512Sum":"aae37fe715c4516b24ac2f6a89ec58f224a8e78501b4d1be4316a6c19099a337775cace507275a1b0cd9995a8c167344c3598851273cf3f056e289dd1b821aad"}],"ComponentSizeInKB":19300,"CompsigList":["CP070929.compsig"],"FileList":["/CP070929_BUILD_10.data","/CP070929.vmexe64","/CP070929.vmfile","/CP070929_VMw.zip","/CP070929.xml","/payload.json","/CP070929_VMw.zip/index.xml","/CP070929_VMw.zip/vendor-index.xml","/CP070929_VMw.zip/metadata.zip","/CP070929_VMw.zip/vib20/CP070929/HPE_bootbank_CP070929_HPD4.10-8.0.0.20613240.vib","/CP070929_VMw.zip/metadata.zip/vendor-index.xml","/CP070929_VMw.zip/metadata.zip/vmware.xml","/CP070929_VMw.zip/metadata.zip/vibs/CP070929--6978806674108385801.xml","/CP070929_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070929_HPD4.10-8.0.0.20613240.xml"],"Name":"CP070929.zip","SHA1Sum":"ca87fedf08ae3adb9cf3401252db8b436ade86b7","SHA256Sum":"9bd3eb9a1f9dfd0c0ea5a5d6612e7c7b9bda6674dcac3c32a5891f3b276ca5c3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070929","Version":"HPD4.10-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b1165c56296c4e42b1e596bdb6","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.rpm","SHA1Sum":"0c7dea8933eab983e86ba83836e8231c7b74c182","SHA256Sum":"6a0e05e4e396433da4f5dba4e019c7713a7782ed6a6274615315b108565c8cab","SHA512Sum":"8709baa620c73ab75843bacf8a62b95778457f06c1fa5419ce9ff94ee672b503122e5ad058e0bfd9a5ba5e1f810d7088a9be4e187f789d25bcd71a18c7d52800"}],"ComponentSizeInKB":2758,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/7548d4b31e2423b17e226b3ac0379bd0bc3639","./usr/lib/.build-id/0d","./usr/lib/.build-id/0d/2900e9fd035d8d91f101d0b7c4e707dd565fc5","./usr/lib/.build-id/13","./usr/lib/.build-id/13/50b3f3488fd6a731d2d99791b1877bbabc8877","./usr/lib/.build-id/24","./usr/lib/.build-id/24/e6792abf338746ad0942f99a3ade351cdacb29","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/a961a970c43e50f9be03f8133a57ecac30ece4","./usr/lib/.build-id/45","./usr/lib/.build-id/45/0dd756691f6d92d075c2bc45f1d7cd5d82195c","./usr/lib/.build-id/48","./usr/lib/.build-id/48/8d294ed312862acf93e6a40e0ac55c6ed37596","./usr/lib/.build-id/4d","./usr/lib/.build-id/4d/83d2d42f3b4915ca93aec9fd3b8baf3dc91cf7","./usr/lib/.build-id/55","./usr/lib/.build-id/55/27db42e0f3f2c8680ee23d1b520cc90f5c68b7","./usr/lib/.build-id/58","./usr/lib/.build-id/58/9ca6a18b97cf17da851ff93b705998cc8834f9","./usr/lib/.build-id/60","./usr/lib/.build-id/60/a66e0d9a24c4ec8f61a5c4c46b740fc121f621","./usr/lib/.build-id/60/ac67b5788a5d56dea213984d1136b2f7811b02","./usr/lib/.build-id/73","./usr/lib/.build-id/73/aca6043e13126e4674c80680ec1e7f239d58d4","./usr/lib/.build-id/76","./usr/lib/.build-id/76/ae8190ca552a75e99b692288e1e30246cc177a","./usr/lib/.build-id/78","./usr/lib/.build-id/78/47726bbe631136f696f4e730da0f17f5173639","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/06eba570171d3283bf0b1de5a584d0589aa9bf","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/568a1439937da66d73f5223a881f9b47b527ff","./usr/lib/.build-id/8c/9e3f7b7189d77b6796b086c82c36e70623a488","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/b514b3c88d446275910cc5165edfbdd6f1b5f7","./usr/lib/.build-id/94","./usr/lib/.build-id/94/2b9960de1e00ecba8fccd172f8d3c8ca0fc364","./usr/lib/.build-id/96","./usr/lib/.build-id/96/aa91cd3e37f3a2b327b1d757ffafe8ad13d684","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/7dabc9c0fd44f1417171b00eb2e95f562891e4","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/6683559f7e9cc3e3cb2d6a9a73db2b0c4f86ed","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/4a37ea09ab94e75a8eaf28762c02094a50bcbd","./usr/lib/.build-id/bd","./usr/lib/.build-id/bd/3f22b80c827c92264ab22b51b5eafaedd565b9","./usr/lib/.build-id/be","./usr/lib/.build-id/be/8ea687d8c33858cfc34697600a90186358b4f0","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/5501b2b9a08eb37602df0f7d944ff69f40a94c","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/d29cbda3708e9fbecc60a68b79b7a8d0d73206","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/185da50db436bef19f5165757345a328021d35","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/7b568ebdb8626178a6ca31649f1eee4e199fbf","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/c7ba5819e9725721b5efaf5d56b854b64ae4be","./usr/lib/.build-id/e4","./usr/lib/.build-id/e4/e41670a17af1b411ed0587c858d85b3306b38b","./usr/lib/.build-id/e5","./usr/lib/.build-id/e5/8c15560c7422ad86a53e34f03cfd3b924f573d","./usr/lib/.build-id/e7","./usr/lib/.build-id/e7/b460ea20448aa65a6cce12c0c8e5969f322e3b","./usr/lib/.build-id/ee","./usr/lib/.build-id/ee/89009c87319a1af4ef176e114a77b9914b6353","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/d3098487911ee8dfc068fa0c98caeb65a5ea33","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/46171a5b24c7ca69accd4e438bdec6d6fc7d50","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/b0ecc1311fc341352125e37d8542f02bfde07c","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/fe1658382c898dc8ec8d82403cdc42038992fb","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/449874232faa11d41ce038efd430d043a22af6","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.rpm","SHA1Sum":"0c7dea8933eab983e86ba83836e8231c7b74c182","SHA256Sum":"6a0e05e4e396433da4f5dba4e019c7713a7782ed6a6274615315b108565c8cab","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.rpm","SHA1Sum":"7ec36f55051084ea6defdc034d9a64ead2088c74","SHA256Sum":"17d7a572cc79b855d004858ab94e81d52bf1692ffe5758ae96026895bc22c0b7","SHA512Sum":"8e226cef53ee34071f8691d929ea23543c6272a8568fb294b921a6c7135a9b24cf395db119f807cc91272406c787961e68db2905401c1dae9738aefba88f6864"}],"ComponentSizeInKB":1992,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/02","./usr/lib/.build-id/02/e44353fa850ffd9aa7bb85810373e293fb4e7f","./usr/lib/.build-id/12","./usr/lib/.build-id/12/06539ee0904cf829de0309f963cca7d87987e2","./usr/lib/.build-id/18","./usr/lib/.build-id/18/69a48c0f71c97ea9549a621a335b65695e853e","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/2e82d2b820a1a913fd5d95ce5761e2fb3e4176","./usr/lib/.build-id/1c","./usr/lib/.build-id/1c/35ea925090feeabe0e2a5d163f9fe655b04bff","./usr/lib/.build-id/2c","./usr/lib/.build-id/2c/440f5567574df7af8855587bc46b58689a074f","./usr/lib/.build-id/2c/966d6358b5acecc83d9890c87d24c2af1b634d","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/385d753f92aef1a637ec7878741b42d0080d58","./usr/lib/.build-id/80","./usr/lib/.build-id/80/da383987f7cc582a9fcb9fe23434464f856d70","./usr/lib/.build-id/9d","./usr/lib/.build-id/9d/4e8f94e5990b582d39daafc25c0db54042cc23","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/5e99478d4c4c043de8f4aeac9dfc819531fd88","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b0c1ae3cfa518477a57da1c88a73f6a4b23e8c","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/22acac57daafbbfcd5b01b060812511e16904c","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/80b11215e601a3e8f1b6db28731435ac013754","./usr/lib/.build-id/bc","./usr/lib/.build-id/bc/b44092db5ea572f5267751014c44525dccdc82","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/6d55c7d5898beb5eab4d6491aeeb3a9b0ff501","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/17c74cf52fadfb67b2eed0c095eeefb92fa17b","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/54705c1e468f44ffef135c4e81e43c795a0b57","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/c7c2b1ba487b6299289ada024edc44132b730b","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/d9abe05bf048dc95e705d1cede5b6e63d0299f","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/ad50a9a16131c71b4751c781ee1b9baf220d83","./usr/lib/.build-id/f6","./usr/lib/.build-id/f6/5def2aa440070a9c216922fce9fcb2da27d652","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.rpm","SHA1Sum":"7ec36f55051084ea6defdc034d9a64ead2088c74","SHA256Sum":"17d7a572cc79b855d004858ab94e81d52bf1692ffe5758ae96026895bc22c0b7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 1 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c87aa8b9d084acfb0a4160890","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U69","U69","U70","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"WDC_ParisD_WparisdASFD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-304a584d5655","Version":"HPD1"}]},"Files":[{"Checksum":[{"Filename":"WDC_ParisD_WparisdASFD1.fwpkg","SHA1Sum":"6d125c64f6010da733f3f0c516e9cbac9d7548f0","SHA256Sum":"1d06562bfb78ad03ea253724415b4cc9d536be3359e87fbf66ed567151f2c4ab","SHA512Sum":"dc8610db05a303fdf6a5f8ec0f4b685ed570b9403302bd55b82cd1cf2c379cc9c34a0d2a0e41b3d93760690024a7d44cdd6fc457dd98524211987c65acdbd227"}],"ComponentSizeInKB":6386,"CompsigList":[],"FileList":["payload.json","WDC_ParisD_WparisdASFD1.HPb","WDC_ParisD_WparisdASFD1.xml"],"Name":"WDC_ParisD_WparisdASFD1.fwpkg","SHA1Sum":"6d125c64f6010da733f3f0c516e9cbac9d7548f0","SHA256Sum":"1d06562bfb78ad03ea253724415b4cc9d536be3359e87fbf66ed567151f2c4ab","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5655"],"TypeOfChange":"1","Version":"HPD1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB020000JXMVU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_12e10145ad2c40a5aeb104112f","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5655"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072096.exe","SHA1Sum":"d38162a403a460f9595044cae05cdd40d504f9c6","SHA256Sum":"ec5de94ef691ea6e804ada02d701dfbd265cca5a29573706e4a7ac19d3c06fa5","SHA512Sum":"7d5cd8b31a6b43c2ef31a82b9ae3829475fd3d16169cb9e4d44eba1f11556204cb43605317d248ffbf30d8cbd59a231969d28fb4538fcff0ca9f1ff7b830c47a"}],"ComponentSizeInKB":8983,"CompsigList":["cp072096.compsig"],"FileList":["cp072096.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSACLI66590_X64.msi"],"Name":"cp072096.exe","SHA1Sum":"d38162a403a460f9595044cae05cdd40d504f9c6","SHA256Sum":"ec5de94ef691ea6e804ada02d701dfbd265cca5a29573706e4a7ac19d3c06fa5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssacli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d9360f5551246ff8132f5231c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A42","A47","A48","U50","U47","A46","U47","U50","A43","A43","A43","HPE Apollo 6500 Gen10 Plus (Chassis)","U48","O43","I44","I45","U63","U58","U59","U54","U54","U54","U63","U58","U58","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U65","U62","U68","U71","U71","U68","U72","A66","A66","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070550.exe","SHA1Sum":"14152a287d62bf9e8de40681cd229f42c29daa18","SHA256Sum":"886cd38086296992c5f30aff5f42c302b3093dc1b101905e5802ef8e367c5a8f","SHA512Sum":"1d44ca575b641c7de283b031a826caa071cbf175199f77aff8596238b33ca47a25c21cbc56a76da5ed3c15750f859441438f87a2357172c4db6c997ba82dbcba"}],"ComponentSizeInKB":1386,"CompsigList":["cp070550.compsig"],"FileList":["cp070550.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp070550.exe","SHA1Sum":"14152a287d62bf9e8de40681cd229f42c29daa18","SHA256Sum":"886cd38086296992c5f30aff5f42c302b3093dc1b101905e5802ef8e367c5a8f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.18.161.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7afd1305385d48b3896fc0dea5","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.fwpkg","SHA1Sum":"c9e0d1561ef4ab3344cbe9b925fbd3a98d41c57a","SHA256Sum":"e91eedca6d8c59c36bd7b0346e60d58cd4007389cd3dddd4df6a22f5162375b6","SHA512Sum":"b72983a6c9014cf3e34b5c4ea6bd0a9204c1fe589a6e0886da64452c33a279bb2e6d35ccf5f8a429e28e7f1c7ffaddd90b9df212e98fb062531383c3df5eaa86"}],"ComponentSizeInKB":5513,"CompsigList":[],"FileList":["16_35_8008-MCX562A-ACA_Ax_Bx.pldm.signed","16_35_8008-MCX562A-ACA_Ax_Bx.pldm.xml","payload.json"],"Name":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.fwpkg","SHA1Sum":"c9e0d1561ef4ab3344cbe9b925fbd3a98d41c57a","SHA256Sum":"e91eedca6d8c59c36bd7b0346e60d58cd4007389cd3dddd4df6a22f5162375b6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30052"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX562A-ACAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6b991dd9868344ce9f5a5a03dc","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U54","U54"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.deb","SHA1Sum":"b6c73d0f1c0f1e3241d3895f69848e5cfbe6629d","SHA256Sum":"e0af644a9d0c578a365819ab7d0aea973c8be7e25f2e5a9d694afc393ceb215b","SHA512Sum":"7f40fd1f39d91a58a738b1fd7c813186c7d79d860cba629d93c59d755980edd82f0e1cc79c88c43c0b78c0f4eb7390e1721e4f0bff79e5ef4a63e193a3a117fa"}],"ComponentSizeInKB":4297,"CompsigList":["firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/CP071705.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071705.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071705.scexe"],"Name":"firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.deb","SHA1Sum":"b6c73d0f1c0f1e3241d3895f69848e5cfbe6629d","SHA256Sum":"e0af644a9d0c578a365819ab7d0aea973c8be7e25f2e5a9d694afc393ceb215b","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e1fcb8ec58a141648617858208","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U41_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U41_3.66_04_01_2026.fwpkg","SHA1Sum":"8a800c83e79367c6c56e3aa0aeffa8b2a16e3044","SHA256Sum":"68ff74debab98854a44ffccf6c0e694084080660b8c2fb24b4378e24264584c0","SHA512Sum":"b1b019beace3ce1fe7135c2a40bfc56bf0d2ccd005bfe8b1396e9ab1f78e03202bf1b8651e79afa3abd6253ff9ce2ec69b8023a3777d6b185e954f83e04a81cf"}],"ComponentSizeInKB":32825,"CompsigList":[],"FileList":["payload.json","U41_3.66_04_01_2026.signed.flash","U41_3.66_04_01_2026.xml"],"Name":"U41_3.66_04_01_2026.fwpkg","SHA1Sum":"8a800c83e79367c6c56e3aa0aeffa8b2a16e3044","SHA256Sum":"68ff74debab98854a44ffccf6c0e694084080660b8c2fb24b4378e24264584c0","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e0daf4460b4b43bf8652a3f888","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-42aff4675b_0HPD5-2.1_amd64.deb","SHA1Sum":"2e2da8c1f7b7217973c3a25c25ae56e8e8e99cc5","SHA256Sum":"9b5b555e64019a10700a61bff1f9a42ae9e077096a068ff098a910217cfca521","SHA512Sum":"6005afded9e1eebb761adc434f83382fb07be8bdc40c979c8fad8a0f445dbf5d96856a17e20264a5a2fbbcefbddd488497db24d82d88216a4dceb3b24cd399b9"}],"ComponentSizeInKB":4364,"CompsigList":["firmware-hdd-42aff4675b_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/CP071771.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071771.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071771.scexe"],"Name":"firmware-hdd-42aff4675b_0HPD5-2.1_amd64.deb","SHA1Sum":"2e2da8c1f7b7217973c3a25c25ae56e8e8e99cc5","SHA256Sum":"9b5b555e64019a10700a61bff1f9a42ae9e077096a068ff098a910217cfca521","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b1fe3d4799f44ddb429596db2","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3531-3330-305058444256","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c993b31232_0HPG6-2.1_amd64.deb","SHA1Sum":"f954f0a9dd6bf8bd055954516616b5455e9c4120","SHA256Sum":"7398842598e348c654e3768fdba680eb1487926a6b6cbce5dabf5fbbe08a6549","SHA512Sum":"2fba5a8f65e783ac461e83acd8ede9374f12c5c44121ea1a730d2943bbc32221f16444bcf0b94bfd1707292ae17e2e9bb3af9531a8e81b56517495053d0de260"}],"ComponentSizeInKB":3546,"CompsigList":["firmware-hdd-c993b31232_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/CP071716.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071716.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071716.scexe"],"Name":"firmware-hdd-c993b31232_0HPG6-2.1_amd64.deb","SHA1Sum":"f954f0a9dd6bf8bd055954516616b5455e9c4120","SHA256Sum":"7398842598e348c654e3768fdba680eb1487926a6b6cbce5dabf5fbbe08a6549","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_11baeec6941e42e1b4374b3c30","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070519.zip","SHA1Sum":"8d1aba01c3ad5582fbd38c3480a2bcec49457805","SHA256Sum":"cafe16b17284c014dee5a36ba1cae4ebe900f870095eccd2c4bad09942ad6439","SHA512Sum":"cebda026ad80a7fa83fe0d95aa03a572a0fbcb8bc65efbe77f7a45bcc9504a99efe75ead6bebbf3ae3fc9ef40a6c95aa4658a8827c902c373bc3621112bedc53"}],"ComponentSizeInKB":701,"CompsigList":["cp070519.compsig"],"FileList":["/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip","/cp070519.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/vendor-index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_91.5.5.86.0-1OEM.900.0.24755229.vib","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/qlnativefc--987473699257504115.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.xml"],"Name":"cp070519.zip","SHA1Sum":"8d1aba01c3ad5582fbd38c3480a2bcec49457805","SHA256Sum":"cafe16b17284c014dee5a36ba1cae4ebe900f870095eccd2c4bad09942ad6439","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"91.5.5.86.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:91.5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:91.5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ce00fbd4b013426f98c16e3080","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-30525852514b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-305258525248","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-30525852524b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30525852514c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-30525852524c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30525852524e","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305259455744","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","SHA512Sum":"4079f4c67efc5491e13b6fe47e415d6d9be5b0fd29bf58ce4295c9b885bd4a07d52c7e387f52d8f53ea4bbd277c817b366c1ba26a214fa3ac5a7b6befe002ef6"}],"ComponentSizeInKB":2091,"CompsigList":[],"FileList":["payload.json","Seagate_Cooper_SCOOPRHPESD4.HPb","Seagate_Cooper_SCOOPRHPESD4.xml"],"Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000960RXRQK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXRRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXRRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXRQL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXRRL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXRRN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680RYEWD","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_351d50a2bba345ebbd72893c5d","SupportedDevices":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071479.zip","SHA1Sum":"01b7f8957c671fef7ceda7c9c26f2a1413667679","SHA256Sum":"5e384c04eeb74ba9d326a847b95f1c461d16d8c8c47f26d742adbb77d77d7ef8","SHA512Sum":"4865b866b8dd528a50e6498cb84590173fe3c28456415002b1e04fc9a1246f9ad282f20da86deece96c7c8b76c50d550dd21f82e0617d35b9d82d78df737c500"}],"ComponentSizeInKB":380,"CompsigList":["cp071479.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip","/cp071479.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_237.1.132.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_237.1.132.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtroce-568144076460741377.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtnet--578145040878030357.xml","/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_237.1.232.0-1OEM.900.0.24755229.xml"],"Name":"cp071479.zip","SHA1Sum":"01b7f8957c671fef7ceda7c9c26f2a1413667679","SHA256Sum":"5e384c04eeb74ba9d326a847b95f1c461d16d8c8c47f26d742adbb77d77d7ef8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2026.05.00","VibList":[{"Name":"bnxtroce","Version":"237.1.132.0-1OEM.900.0.24755229"},{"Name":"bnxtnet","Version":"237.1.132.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:237.1.232.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:237.1.132.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:237.1.132.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3174f9de543e4ff18fe011a0ce","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U46","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","SHA1Sum":"cb33486cafbd20d0f1298d22a21169bd35d9edb8","SHA256Sum":"2e17168c58f84f9e4b4626f9bba5c8c35e138c6ab510427abbed453f4f92b556","SHA512Sum":"c789c15352edac3a9ef32a9c4298d01896173dfe369bea59429c90f9455773fedefbc8c7d3cf8a0dc74c38af318f79046d9c2bf73655683aecb3ff10ad669dd3"}],"ComponentSizeInKB":6379,"CompsigList":["firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/CP068805.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068805.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068805.scexe"],"Name":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","SHA1Sum":"cb33486cafbd20d0f1298d22a21169bd35d9edb8","SHA256Sum":"2e17168c58f84f9e4b4626f9bba5c8c35e138c6ab510427abbed453f4f92b556","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e33cb3609b14b61a246f9ddee","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069507.exe","SHA1Sum":"fbea9ac74c57d772a7462b66e298aae98b140913","SHA256Sum":"1debcfaf8c2d1cf68e163a70a84b31d842c5456175fc6d4f60571b6502858e7f","SHA512Sum":"559ed2eeb1793e313abf60a13c48ec1d8e6a3a09ae58e79c2db1f686ca159f5ad3c8284639c957fb0554bcdbfc218a05c9188b81f167177c4e43b3af7fc0ccf3"}],"ComponentSizeInKB":921,"CompsigList":["cp069507.compsig"],"FileList":["cp069507.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","megasas35.inf","megasas35.pdb","megasas35.RttMeta","megasas35.sys","nodev.inf"],"Name":"cp069507.exe","SHA1Sum":"fbea9ac74c57d772a7462b66e298aae98b140913","SHA256Sum":"1debcfaf8c2d1cf68e163a70a84b31d842c5456175fc6d4f60571b6502858e7f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.736.3.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1bee086dba7449cbb397135184","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.deb","SHA1Sum":"29b59dc129b0321951dc22dee86f078e17d7bc18","SHA256Sum":"8cc2a8758b8a728ff6d996984a13ac8e0cc2804bf0c8f425708d239d156505e3","SHA512Sum":"69bbafe84538d4ca6165c89e0b9e5934f3f3012984bcec9395dfe2ec70f54afca04ff21075d0b8efca8cc307182ddc92993d7282b1a16c674cc6afce6877b105"}],"ComponentSizeInKB":4784,"CompsigList":["firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/CP071780.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071780.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071780.scexe"],"Name":"firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.deb","SHA1Sum":"29b59dc129b0321951dc22dee86f078e17d7bc18","SHA256Sum":"8cc2a8758b8a728ff6d996984a13ac8e0cc2804bf0c8f425708d239d156505e3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f9efda9935f14c56a04a9de437","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U33_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U33_3.66_04_01_2026.fwpkg","SHA1Sum":"36630e0bde260091be02ed4b9a7c705c28fd8ef8","SHA256Sum":"dcc8775def0510e3ded37b71cd9f4d078163a1a3b8bbe262fd700e6e138d7e66","SHA512Sum":"f7888c518cf0a5e0b9475d86e6f9aea5749305f0d29d57009221fed69493139b1d4458cc5ce52db83d929c5456a2460477b4302695601fa90695ba04343d9453"}],"ComponentSizeInKB":32825,"CompsigList":[],"FileList":["payload.json","U33_3.66_04_01_2026.signed.flash","U33_3.66_04_01_2026.xml"],"Name":"U33_3.66_04_01_2026.fwpkg","SHA1Sum":"36630e0bde260091be02ed4b9a7c705c28fd8ef8","SHA256Sum":"dcc8775def0510e3ded37b71cd9f4d078163a1a3b8bbe262fd700e6e138d7e66","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_693d74f531a846a990bd103a63","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U50_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u50-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"7f9a28b6843fe8f98c90b0bf3016c3fe19f1b275","SHA256Sum":"40b4298a4a124be27a5400184d6ab533189ed6ac9c8ae655ddb3550e5bccfc2d","SHA512Sum":"aaa4c367474f66f90492bce2a62cd0bb96d4686f9e65fdec0088232a2cef6a34ee3a409ac427d0bf15f1aa8c4d199d33740625940e3e6c9318e3682788e06fa1"}],"ComponentSizeInKB":33273,"CompsigList":["firmware-system-u50-2.64_2026_04_01-1.1.x86_64_part2.compsig","firmware-system-u50-2.64_2026_04_01-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/CP071462.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/U50_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071462.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071462.scexe"],"Name":"firmware-system-u50-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"7f9a28b6843fe8f98c90b0bf3016c3fe19f1b275","SHA256Sum":"40b4298a4a124be27a5400184d6ab533189ed6ac9c8ae655ddb3550e5bccfc2d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e0f71a1f8c9a42d9aec5b7faa3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.deb","SHA1Sum":"21e186b3739b9a52bae75ce89a241019ce0fe798","SHA256Sum":"edcc04832df7c0be99a8d63cfba58f514134f1ccf9e09db0d27d6772831dd634","SHA512Sum":"e14f605728557415e39de643e982c64e4a92f3989ea26da8ee79b39b4706446e06e217d501270683ceef202a4126e6b998e28c010edc6a8764c2d737200658f5"}],"ComponentSizeInKB":4506,"CompsigList":["firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/CP071767.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071767.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071767.scexe"],"Name":"firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.deb","SHA1Sum":"21e186b3739b9a52bae75ce89a241019ce0fe798","SHA256Sum":"edcc04832df7c0be99a8d63cfba58f514134f1ccf9e09db0d27d6772831dd634","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1f243a97265142368b07595bdd","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000-6.00-12.1.x86_64.rpm","SHA1Sum":"e6e7c86d19b8abc2958c8b6cbc74cce77f187093","SHA256Sum":"29ba6620302490b2f5b4f19404e502b90a530aff98b51973cb42e4cd4a3912bd","SHA512Sum":"45d2b46d4ccdd3dc018640721d35f94cb07275a9d0e0af9d6a37841f3b845a9c3847811c88de533f654d718334b60523b745565c82df6b2b0f18d42479564e81"}],"ComponentSizeInKB":3545,"CompsigList":["firmware-d3000-6.00-12.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/CP072208.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072208.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072208.scexe"],"Name":"firmware-d3000-6.00-12.1.x86_64.rpm","SHA1Sum":"e6e7c86d19b8abc2958c8b6cbc74cce77f187093","SHA256Sum":"29ba6620302490b2f5b4f19404e502b90a530aff98b51973cb42e4cd4a3912bd","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c0128085a662490d80d8a1560b","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070316.exe","SHA1Sum":"2d19d349ce138b4890a64d5a36f391db707c957c","SHA256Sum":"56535fad8b725ccb4b1f2ee7a2c6cb6481d42f3b3bb5115ca7c9a11ef35491df","SHA512Sum":"b0f1ca3f98ded336caf37e75e752ac7a07c2cf2bb732cce5df9cb94cf686362959cf2e0ebb19bf4f06eadfbc4e74a9cf0fcde5281c226f2364aad8cafd0e1888"}],"ComponentSizeInKB":4199,"CompsigList":["cp070316.compsig"],"FileList":["cp070316.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.1-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp070316.exe","SHA1Sum":"2d19d349ce138b4890a64d5a36f391db707c957c","SHA256Sum":"56535fad8b725ccb4b1f2ee7a2c6cb6481d42f3b3bb5115ca7c9a11ef35491df","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.1"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f2905e806184e86b5f2fb646d","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssa-6.65-9.0.x86_64.rpm","SHA1Sum":"32745c5c181925e3108f5d1391a4e6da1a683d36","SHA256Sum":"1b837fc3381ce9f9b070a3305ab9771568dd2ac40a847863b9171dcec8ed6764","SHA512Sum":"52bcad76fe94888d284c2a4c274deec357db1793a1b34a9d9ed499ec78728e1e393a78bddc1d487f08ae1bf8cc1a49056f4000d7f766a48d9d549f7d406d187f"}],"ComponentSizeInKB":9572,"CompsigList":["ssa-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"Name":"ssa-6.65-9.0.x86_64.rpm","SHA1Sum":"32745c5c181925e3108f5d1391a4e6da1a683d36","SHA256Sum":"1b837fc3381ce9f9b070a3305ab9771568dd2ac40a847863b9171dcec8ed6764","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81f4244b8dd0486ba9d71c3ba3","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U63","I45","U58","U58","U58","U59","U54","U54","U63","U54","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U18","U18","U18","U21","U25","U27","U24","U13","U13","U12","U14","U14","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","Carbondale14","U19","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","U71","A66","U71","U68","U68","A66","U68","U72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072380.zip","SHA1Sum":"391dec687b0bffeaf942382a82f99e49686e905e","SHA256Sum":"6107a93d67a09e67f311552b661f0c251a424cabafb0de211c0e98a2a13d621d","SHA512Sum":"0f1194e79b7e97a2f3669111225180cdceca6dd3dfc6ff80584fe26a97b4ddd0f1e38bbf7ef2ad711b66edacecd58d9f5c3d990e2c44747a42928ca11103408e"}],"ComponentSizeInKB":17164,"CompsigList":["CP072380.compsig"],"FileList":["/CP072380.xml","/CP072380_VMw.zip","/payload.json","/CP072380.vmexe64","/CP072380.vmfile","/CP072380_VMw.zip/index.xml","/CP072380_VMw.zip/vendor-index.xml","/CP072380_VMw.zip/metadata.zip","/CP072380_VMw.zip/vib20/CP072380/HPE_bootbank_CP072380_1.0.0-8.0.0.21495797.vib","/CP072380_VMw.zip/metadata.zip/vendor-index.xml","/CP072380_VMw.zip/metadata.zip/vmware.xml","/CP072380_VMw.zip/metadata.zip/vibs/CP072380--3244865110063769315.xml","/CP072380_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072380_1.0.0-8.0.0.21495797.xml"],"Name":"CP072380.zip","SHA1Sum":"391dec687b0bffeaf942382a82f99e49686e905e","SHA256Sum":"6107a93d67a09e67f311552b661f0c251a424cabafb0de211c0e98a2a13d621d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.4","VibList":[{"Name":"CP072380","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_686f4d0a3bd64f50b82020a09f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssa-6.65-9.0_amd64.deb","SHA1Sum":"11025e8cf7d4f1a23e64234fc0d4c3faef66663e","SHA256Sum":"0d62f86c317968940e3dd72f0fa7ec4e6f452692afcff406a99df65e6a2df43c","SHA512Sum":"834179f8d5b8ac562a8bc613d58b8be51d324064ef7d04375208806d8d2ec672ca8a159dbcfc3c176171066660ed0aec0b5ee03f6345df6ca927a26942fb347b"}],"ComponentSizeInKB":7416,"CompsigList":["ssa-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/sbin/ssa","./usr/share/doc/ssa/changelog.Debian.gz","./usr/share/doc/ssa/copyright","./usr/share/man/man8/ssa.8.gz","./usr/share/smartupdate/ssa/component.xml"],"Name":"ssa-6.65-9.0_amd64.deb","SHA1Sum":"11025e8cf7d4f1a23e64234fc0d4c3faef66663e","SHA256Sum":"0d62f86c317968940e3dd72f0fa7ec4e6f452692afcff406a99df65e6a2df43c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f380215792b04537b788d24d31","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U63","I45","U58","U58","U58","U59","U54","U54","U63","U54","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U18","U18","U18","U21","U25","U27","U24","U13","U13","U12","U14","U14","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","Carbondale14","U19","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","U71","A66","U71","U68","U68","A66","U68","U72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U37_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U37_3.66_04_01_2026.fwpkg","SHA1Sum":"f4442f3720119a38ce00f90de814ce366303f99d","SHA256Sum":"24f99bc020f87216ce255b1b30c7ff7b062c3b892c37443de3b080bc146cf073","SHA512Sum":"74868c3c20549003f73a37d7181749b91e1b73b4ae6c3609e730cac08be1568131a1e52112b05ef1890ce20e230767548ce3bdcdc45b89f51ce7d19e21eb84e7"}],"ComponentSizeInKB":32821,"CompsigList":[],"FileList":["payload.json","U37_3.66_04_01_2026.signed.flash","U37_3.66_04_01_2026.xml"],"Name":"U37_3.66_04_01_2026.fwpkg","SHA1Sum":"f4442f3720119a38ce00f90de814ce366303f99d","SHA256Sum":"24f99bc020f87216ce255b1b30c7ff7b062c3b892c37443de3b080bc146cf073","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d191578ed0854637821af5a78c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U45_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U45_3.66_04_01_2026.fwpkg","SHA1Sum":"8995345021c2aefc7ff7f40115624fde634dac74","SHA256Sum":"1772fb43e57d550c2d17c51c8e24871e3e8e9070067887bc6790187cfb8e0a3f","SHA512Sum":"e2048c310d4a55c25cdea04dc2d481fe1db1754e33c047dea25944d73be5fb6a72ac5d89045236d714513b0f79f5d6547dfaf982bf17c7d85f4f5d5702675056"}],"ComponentSizeInKB":32824,"CompsigList":[],"FileList":["payload.json","U45_3.66_04_01_2026.signed.flash","U45_3.66_04_01_2026.xml"],"Name":"U45_3.66_04_01_2026.fwpkg","SHA1Sum":"8995345021c2aefc7ff7f40115624fde634dac74","SHA256Sum":"1772fb43e57d550c2d17c51c8e24871e3e8e9070067887bc6790187cfb8e0a3f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_43956306e38b431384fdd41148","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H08_3.64_02_05_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.64 (02/05/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-h08-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"b62a9cad5b8ef7bb378f6067f9e987829b641c8e","SHA256Sum":"de82e2824b9f5fb7b50ad2b6c2d9a1d845cbedbb6eefc8f1669d3a038c64740b","SHA512Sum":"a5a27933f056f8c5cd10bae11bc3240699695c5b8e19df65c6e72af66e7d107d4be5921dc1ed2cb8d4a27bac631d322245ff51cbdb7b573a56baae7c74f8d071"}],"ComponentSizeInKB":11024,"CompsigList":["firmware-system-h08-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/CP071474.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/H08_3.64_02_05_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071474.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071474.scexe"],"Name":"firmware-system-h08-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"b62a9cad5b8ef7bb378f6067f9e987829b641c8e","SHA256Sum":"de82e2824b9f5fb7b50ad2b6c2d9a1d845cbedbb6eefc8f1669d3a038c64740b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f50097c941dd4116af4c1c373a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.rpm","SHA1Sum":"ee69d688055dd32b0781180538a84d77b5275605","SHA256Sum":"f717708c908e581db9e102f66932c57ff1afc88e875ff32e0d1b23d8631b4da9","SHA512Sum":"1f505cd7846de4a144bbca5bbc9ebaf4b8d2d529b39d81c873130aa947fbca34a2c3e5cac13f07596db3ae73a1480e07294a010ce72f4663e7890ecfd0b552fe"}],"ComponentSizeInKB":78,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/mst_pci.ko","./lib/modules/6.4.0-150600.21-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.rpm","SHA1Sum":"ee69d688055dd32b0781180538a84d77b5275605","SHA256Sum":"f717708c908e581db9e102f66932c57ff1afc88e875ff32e0d1b23d8631b4da9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.sles15sp6.x86_64.rpm","SHA1Sum":"0a0cdda1ff29c4608f69e0eb22da35e27a365c0d","SHA256Sum":"656892c414ea5f8c346af2876c6631376fbefb681069024d13bbcb152aa25133","SHA512Sum":"a87bd750a9881b7463cea4384e8b9e7551d93d7faab0b566aa15a66e450919a8625739ec9a146f506df7cb5211fe5cb27a56db967728c71d6d13f00313759bd5"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles15sp6.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles15sp6.x86_64.rpm","SHA1Sum":"0a0cdda1ff29c4608f69e0eb22da35e27a365c0d","SHA256Sum":"656892c414ea5f8c346af2876c6631376fbefb681069024d13bbcb152aa25133","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_286ec51774394c74a66df96ff7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","SHA1Sum":"4e3b9f5caa71ece323a7e4874769839b6158dc6d","SHA256Sum":"e4e70ee788f00bcedbf62137e058ca311fe3ea58aa47907359a927ca10ae76de","SHA512Sum":"f6b2c27093fa18eceefb1fb89b7e7a9103b0cc7eb587cd3bcde358b6d73aa09c7aa92e28518a2a1c501ae9f85c7cd98799df314b342841e51ea18be24230dad6"}],"ComponentSizeInKB":6147,"CompsigList":["firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/CP068920.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068920.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068920.scexe"],"Name":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","SHA1Sum":"4e3b9f5caa71ece323a7e4874769839b6158dc6d","SHA256Sum":"e4e70ee788f00bcedbf62137e058ca311fe3ea58aa47907359a927ca10ae76de","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b5a913647d7640cd9a84628e9c","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","SHA1Sum":"0cdddbd0447af5b7367cbfc8e447e4a7c096767a","SHA256Sum":"9015b33f9db4806ea4ad0ad594d36aaf326891015f73f23a8668d2d4d4b1d19b","SHA512Sum":"6689a5b9126da7bd87b4087b6b3e472c0f93074d1c6fca45dd766f463b279420bd0132c3fab77f6d4167d4444231a62bd598c27b601a4da3a5329d912c7f5f7e"}],"ComponentSizeInKB":7037,"CompsigList":["firmware-hdd-d550523365-HPD3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/CP068850.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/PCHFA2B3.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068850.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068850.scexe"],"Name":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","SHA1Sum":"0cdddbd0447af5b7367cbfc8e447e4a7c096767a","SHA256Sum":"9015b33f9db4806ea4ad0ad594d36aaf326891015f73f23a8668d2d4d4b1d19b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd1b23f75c144dcbb22cd0a6a6","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"ffdc875d81c1216e626442ce8aee3d7c46312152","SHA256Sum":"fe46a9deb512e16d70fbb006dfb0640925bac9ced1766ec9561d5fb7d2eb8355","SHA512Sum":"818f9063775b8d518a6700442ac0b878dd0f7377f273daea522518246f4b3b05157e64449988284a4f08cde7ceeacb41882cce7c539bb041e68ae80347aa29ba"}],"ComponentSizeInKB":81,"CompsigList":["hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"Name":"hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"ffdc875d81c1216e626442ce8aee3d7c46312152","SHA256Sum":"fe46a9deb512e16d70fbb006dfb0640925bac9ced1766ec9561d5fb7d2eb8355","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.2.2-1"},{"Checksum":[{"Filename":"hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"e2daba07576a0b91207cae540d0647536641bc04","SHA256Sum":"bd8f048bba011de30ad11e074c44e3d888a44fd9b3b904e7dc14bf87898cee1f","SHA512Sum":"1ca8917642a30a56cc484a5c7e15aee9800e50ea33ef82649353917a0cccf870e3a4b5a32fe7cc2b94b91aac858b983382bbaf47f5a67955110934fbc3810751"}],"ComponentSizeInKB":80,"CompsigList":["hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"Name":"hp-ixgbevf-kmp-default-5.2.2_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"e2daba07576a0b91207cae540d0647536641bc04","SHA256Sum":"bd8f048bba011de30ad11e074c44e3d888a44fd9b3b904e7dc14bf87898cee1f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.2.2-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36a348b50cb5497993fd877872","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-35fd24601f_0HPD5-2.1_amd64.deb","SHA1Sum":"068ad755eee3cae619b805e3bd193d130a0a6e8c","SHA256Sum":"1d7ca12ec76c2a4cf42b6ac1097ae2ffe8fef575b037096f3ef9105c44045cfd","SHA512Sum":"733cf5c36e34f72b69a2688d1e5710eb0494941bb43f25e98201073f19ae1c602f0487770d80c8f04d3b01e8a2093fb65818ad19f4a994b5b36a5ce50c881cac"}],"ComponentSizeInKB":3656,"CompsigList":["firmware-hdd-35fd24601f_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/CP071752.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071752.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071752.scexe"],"Name":"firmware-hdd-35fd24601f_0HPD5-2.1_amd64.deb","SHA1Sum":"068ad755eee3cae619b805e3bd193d130a0a6e8c","SHA256Sum":"1d7ca12ec76c2a4cf42b6ac1097ae2ffe8fef575b037096f3ef9105c44045cfd","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ab822b19174f4e0cbbab720147","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.deb","SHA1Sum":"cd91220ebb47cb449bf0c950d120cdce4652e1d3","SHA256Sum":"df89c5dbf765b0696c4c4588515408bb17b8a4008dbd755884a9775fa9d9d734","SHA512Sum":"9f179313a598c16ba4022cc744a34acce635b3014bc5bc2ec40ba00fcd35fcf0515f1d39e811fec2eda14588542813bcb9a3144484f26afe84c946743dc0a1d3"}],"ComponentSizeInKB":3549,"CompsigList":["firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/CP071732.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071732.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071732.scexe"],"Name":"firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.deb","SHA1Sum":"cd91220ebb47cb449bf0c950d120cdce4652e1d3","SHA256Sum":"df89c5dbf765b0696c4c4588515408bb17b8a4008dbd755884a9775fa9d9d734","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd30be672e754b93b9db2577d7","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-4.8.0-2167.4.sles15.x86_64.rpm","SHA1Sum":"1583fe4c6c3f89278c4035cdf0b6c320e3ba9b09","SHA256Sum":"4cb600ed842cedd0393c3bc680ac4015c98a3585a265e367a0efa92a71cb6041","SHA512Sum":"6ce1d67dc689e8ce5284603649db8e4320fbd7f8e6cf866b6e88f52721244cefbfba2eecf430961785156760083cd6dc65bd01f245a8ac00a7b70c63c9078d52"}],"ComponentSizeInKB":11356,"CompsigList":["amsd-4.8.0-2167.4.sles15.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/4cc77ffaa07fcb69f5e6908e0a880b932fce1f","./usr/lib/.build-id/00/4cc77ffaa07fcb69f5e6908e0a880b932fce1f.1","./usr/lib/.build-id/09","./usr/lib/.build-id/09/73f13b1007b5a55b07003e81a44b346c3e9041","./usr/lib/.build-id/09/73f13b1007b5a55b07003e81a44b346c3e9041.1","./usr/lib/.build-id/58","./usr/lib/.build-id/58/f14b53266385904df25dc87c930d69a1387538","./usr/lib/.build-id/73","./usr/lib/.build-id/73/8221452f95af372cc272da0c6f25bd57cc5894","./usr/lib/.build-id/74","./usr/lib/.build-id/74/2d6646847752fab0398d1d1eb6928c8b4b4ded","./usr/lib/.build-id/74/2d6646847752fab0398d1d1eb6928c8b4b4ded.1","./usr/lib/.build-id/77","./usr/lib/.build-id/77/6e7875b7f226b2cb32baa1fd597ee25c7769c3","./usr/lib/.build-id/77/6e7875b7f226b2cb32baa1fd597ee25c7769c3.1","./usr/lib/.build-id/a0","./usr/lib/.build-id/a0/a53dbd66aa75608cbc47b79eb12aff40d7b80d","./usr/lib/.build-id/a0/a53dbd66aa75608cbc47b79eb12aff40d7b80d.1","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/1244be600e6ea1b605494a5e0dafc197ac7524","./usr/lib/.build-id/d4/1244be600e6ea1b605494a5e0dafc197ac7524.1","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/62c047ddc4d144ef8383fda1cc937c8ba26ee6","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-4.8.0-2167.4.sles15.x86_64.rpm","SHA1Sum":"1583fe4c6c3f89278c4035cdf0b6c320e3ba9b09","SHA256Sum":"4cb600ed842cedd0393c3bc680ac4015c98a3585a265e367a0efa92a71cb6041","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.8.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_33cf5affbfdd4877928f13bd46","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U58","U57","U65","U65","U62","A58","U69","U69","H11","I46","U68","U68","U68","U71","U66","U71","U72","U68","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U60_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u60-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"810c16455f140dff3947e81e823c30501793c6ee","SHA256Sum":"46ef9788f426cdd66137610caf858127204441e0cee4f88a94bcada8c0ed2c2c","SHA512Sum":"a4dcbdf59a44d89ee7048b16c443e94d96a854c12102b0efc8f6ebed7e916104f93bdd0378c2321f303cb98f56ca4d025b5e043935807cbc4facd05b1324239f"}],"ComponentSizeInKB":16760,"CompsigList":["firmware-system-u60-2.64_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/CP071346.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/U60_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071346.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071346.scexe"],"Name":"firmware-system-u60-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"810c16455f140dff3947e81e823c30501793c6ee","SHA256Sum":"46ef9788f426cdd66137610caf858127204441e0cee4f88a94bcada8c0ed2c2c","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcf8f1497a76452ea96537eb09","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-3050584d544e","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-3050584d5456","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-3050584d5541","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-3050584d544c","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-3050584d5452","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-3050584d5454","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-3050584d5455","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","SHA1Sum":"8ffe7e5833092e4d4e0b4d96f87b73cabca0792e","SHA256Sum":"f46078c7a23e28323964baeab66839462e839feebb14d388c369f1683232cac5","SHA512Sum":"056b78b98f91e765d43fea575096b2a5d420b9cbbb6d6d3561ee2f8f5a59621c3946d3148790c38bbc1dd5d146ab281773f08f1bc19c2cc6d1a44f726446fd85"}],"ComponentSizeInKB":1539,"CompsigList":[],"FileList":["Kioxia_PM7_KAPM7ALSHPD4.HPb","Kioxia_PM7_KAPM7ALSHPD4.xml","payload.json"],"Name":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","SHA1Sum":"8ffe7e5833092e4d4e0b4d96f87b73cabca0792e","SHA256Sum":"f46078c7a23e28323964baeab66839462e839feebb14d388c369f1683232cac5","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-3050584d544e","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3630-3430-3050584d5541","562340a5-304f-3130-3932-3050584d544c","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3531-3336-3050584d5455"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600PXMTN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PXMTV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PXMUA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PXMTL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXMTR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXMTT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PXMTU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_773c466c982042fea8769d7ddb","SupportedDevices":["562340a5-304f-3531-3336-3050584d5455","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3130-3932-3050584d544c","4d2340a5-304f-3630-3430-3050584d5541","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3130-3630-3050584d544e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","SHA1Sum":"521f5904c2488eb59cec95a9aa2372c677529fef","SHA256Sum":"ab5e8ea1f81b747ff4eefd86994abfdd876e1bda563a71bb3d99ecc04271f5fc","SHA512Sum":"ab02d260494eac641964648bf1d2bea2f55f8636f032d7a2ca6ec515f547b33d04f34de2c7bae7e4b845c5dc5d20119655e54204a23f5a6674099e072eef4f67"}],"ComponentSizeInKB":9810,"CompsigList":["firmware-hdd-befd42bd64-HPG3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/CP068911.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068911.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068911.scexe"],"Name":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","SHA1Sum":"521f5904c2488eb59cec95a9aa2372c677529fef","SHA256Sum":"ab5e8ea1f81b747ff4eefd86994abfdd876e1bda563a71bb3d99ecc04271f5fc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2a06adfbec30486d8f4a28dfef","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070510.zip","SHA1Sum":"dcc7053813bad9832b2dde959026e0c7dbc46609","SHA256Sum":"f257da5edf50f51e0879c2889f723bc445d9608c5bf4bb3f84db81cc8077f72f","SHA512Sum":"b4a8a37459175a73d6c8ba42bef61a9aa054c6ccdd87833419f17bf6c58efe874f714ae1d54cb6bf367adaf38e2cec99db5f655bb5ad87348c265ec657c210b3"}],"ComponentSizeInKB":860,"CompsigList":["cp070510.compsig"],"FileList":["/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip","/cp070510.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.86.0-1OEM.803.0.0.24022510.vib","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vibs/qlnativefc-171623614172578347.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.xml"],"Name":"cp070510.zip","SHA1Sum":"dcc7053813bad9832b2dde959026e0c7dbc46609","SHA256Sum":"f257da5edf50f51e0879c2889f723bc445d9608c5bf4bb3f84db81cc8077f72f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.3"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"5.4.86.0-1OEM.803.0.0.24022510"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:5.4.86.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.86.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c7e37adf75248e4a7551f5be5","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070938.zip","SHA1Sum":"911fc9e15f700361d2fcd3768c321a0d54057a41","SHA256Sum":"3f62e06a69cfc529632a83021c86d0c4571f9f7b1a4f22966ff036652ba87162","SHA512Sum":"ccdd7efa9d89c14097f602a2ebea807e4bfcb5bcbca4960130ff93e2c42df9ba03a2633140ff90401da2479caed431d8faf8d7dae0590ace9050e1ab7f9f0c4d"}],"ComponentSizeInKB":19779,"CompsigList":["CP070938.compsig"],"FileList":["/CP070938_BUILD_4.data","/CP070938.vmexe64","/CP070938.vmfile","/CP070938_VMw.zip","/CP070938.xml","/payload.json","/CP070938_VMw.zip/index.xml","/CP070938_VMw.zip/vendor-index.xml","/CP070938_VMw.zip/metadata.zip","/CP070938_VMw.zip/vib20/CP070938/HPE_bootbank_CP070938_HPD2.4-8.0.0.20613240.vib","/CP070938_VMw.zip/metadata.zip/vendor-index.xml","/CP070938_VMw.zip/metadata.zip/vmware.xml","/CP070938_VMw.zip/metadata.zip/vibs/CP070938-4885375148488135081.xml","/CP070938_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070938_HPD2.4-8.0.0.20613240.xml"],"Name":"CP070938.zip","SHA1Sum":"911fc9e15f700361d2fcd3768c321a0d54057a41","SHA256Sum":"3f62e06a69cfc529632a83021c86d0c4571f9f7b1a4f22966ff036652ba87162","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070938","Version":"HPD2.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4fc4092bc1fb4b8392c7b9be08","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070845.zip","SHA1Sum":"8ae776ada6b428b3ef39308e115a85c418efc61b","SHA256Sum":"0af561d50286d327b7e0c3684e062fd7b2261291d6a0602d8bb781f0212f36c1","SHA512Sum":"a3093edbba6ba51a30a6df57129eacbb74bb530bc9ce3d39c0710d8677eaefe0e516771ddfc2b84ca4096858af1e719e50f6356354a1118f8f085f55d2cc759d"}],"ComponentSizeInKB":259,"CompsigList":["cp070845.compsig"],"FileList":["/cp070845.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/vib20/i40en/INT_bootbank_i40en_2.11.1.0-1OEM.900.0.24755229.vib","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/i40en-824206042229324044.xml","/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-i40en_2.11.1.0-1OEM.900.0.24755229.xml"],"Name":"cp070845.zip","SHA1Sum":"8ae776ada6b428b3ef39308e115a85c418efc61b","SHA256Sum":"0af561d50286d327b7e0c3684e062fd7b2261291d6a0602d8bb781f0212f36c1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"i40en","Version":"2.11.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.11.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_15deefa9b3f2433794d3aa5964","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ixgbe-kmp-default-6.3.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"ff69ab1861e3ce0a3c17bc8560339796c669ac7c","SHA256Sum":"2e5a965ad13cce9e64357b9007b930a19a903b7b74611a350c7d84a24f9f9c79","SHA512Sum":"2c5bb8d3a0d078647805fa43b3c2c86c3118fbb4dd960f9192b234c1655b7664732efdf88e12ec7d2930d4191d51632ab9d58139978bddd7228d9b4cf1113e51"}],"ComponentSizeInKB":434,"CompsigList":["ixgbe-kmp-default-6.3.4_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbe.ko","./usr/share/doc/packages/ixgbe-kmp-default","./usr/share/doc/packages/ixgbe-kmp-default/COPYING","./usr/share/doc/packages/ixgbe-kmp-default/README","./usr/share/man/man7/ixgbe.7.gz","./usr/share/pci.ids.d/pci.ids.ixgbe-kmp-6.3.4","./usr/share/smartupdate/ixgbe-kmp-default/component.xml"],"Name":"ixgbe-kmp-default-6.3.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"ff69ab1861e3ce0a3c17bc8560339796c669ac7c","SHA256Sum":"2e5a965ad13cce9e64357b9007b930a19a903b7b74611a350c7d84a24f9f9c79","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb870faaa"],"TypeOfChange":"1","Version":"6.3.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_72de1746861741ab8b5062cc50","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.37.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.37.41"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-open-2.43.0-1.1.x86_64.rpm","SHA1Sum":"f6a7f5e565a9cb129c500b5290e9076b7cd9807f","SHA256Sum":"5297996d700550df5bbb8a153800da7c1221cab5dabccfb205d6381eb0250de6","SHA512Sum":"a2d45378ef55175039c39173a93f93bff39edbcd2ea16d43f7c5ff3067fd644c93fcdcaad98468c99f8874a9b34cae9e76d2e7ecd4010922d71a04ce4ac39fb3"}],"ComponentSizeInKB":5779,"CompsigList":["firmware-nic-bcm-open-2.43.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/CP071596.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/CP071596.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/nic_fw/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/nic_fw/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/nic_fw/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/nic_fw/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.43.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071596.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071596.scexe"],"Name":"firmware-nic-bcm-open-2.43.0-1.1.x86_64.rpm","SHA1Sum":"f6a7f5e565a9cb129c500b5290e9076b7cd9807f","SHA256Sum":"5297996d700550df5bbb8a153800da7c1221cab5dabccfb205d6381eb0250de6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"2.43.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6f892f5ce7954ee69c11445c6d","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U47","U46","A42","A42","A43","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U68","U72","U70","A66","A66","U77","03030202","03020102","U70"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"},{"DelayAfterInstallSec":180,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"firmware-d8000-0130-13.1.x86_64.rpm","SHA1Sum":"2e118faea754f64e67554dd630c3a437c6ed18e1","SHA256Sum":"afad8cfa3098956f6a185277acb959b3231aaa3470db595329ed760f5c87c5fc","SHA512Sum":"8524d92f21b2e3d80948b660dcfc1656ff957bbd4215e15e13b24ee41d7bd174259e3489a2854e06f524fbfd080a1848346051db42ff8828b52e0ec1d13cb0ec"}],"ComponentSizeInKB":13454,"CompsigList":["firmware-d8000-0130-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/CP072204.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072204.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072204.scexe"],"Name":"firmware-d8000-0130-13.1.x86_64.rpm","SHA1Sum":"2e118faea754f64e67554dd630c3a437c6ed18e1","SHA256Sum":"afad8cfa3098956f6a185277acb959b3231aaa3470db595329ed760f5c87c5fc","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2e7e8bfdf3b645e485e502281d","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070934.zip","SHA1Sum":"8d016657c63a4c5f4b95d71315c3ba9ea7649a38","SHA256Sum":"ee4bdfbb457955a624c5d1b75c52f6fd8f90014c70dd2235fd64aa927688021e","SHA512Sum":"315ba0573e9ed85ed349c14d29e29714814df725d93b4a79773f478347adf6019c5a5097f431ca06350167200417d3958f92d74f851a3ec3d08ef6a527e76047"}],"ComponentSizeInKB":19184,"CompsigList":["CP070934.compsig"],"FileList":["/CP070934_BUILD_2.data","/CP070934.vmexe64","/CP070934.vmfile","/CP070934_VMw.zip","/CP070934.xml","/payload.json","/CP070934_VMw.zip/index.xml","/CP070934_VMw.zip/vendor-index.xml","/CP070934_VMw.zip/metadata.zip","/CP070934_VMw.zip/vib20/CP070934/HPE_bootbank_CP070934_HPDB.2-8.0.0.20613240.vib","/CP070934_VMw.zip/metadata.zip/vendor-index.xml","/CP070934_VMw.zip/metadata.zip/vmware.xml","/CP070934_VMw.zip/metadata.zip/vibs/CP070934--8801092302076112374.xml","/CP070934_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070934_HPDB.2-8.0.0.20613240.xml"],"Name":"CP070934.zip","SHA1Sum":"8d016657c63a4c5f4b95d71315c3ba9ea7649a38","SHA256Sum":"ee4bdfbb457955a624c5d1b75c52f6fd8f90014c70dd2235fd64aa927688021e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070934","Version":"HPDB.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_57188dbcaef94870b9cefff622","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072379.exe","SHA1Sum":"cb40bcc93f55bfe5c33f436034d96954b099aafa","SHA256Sum":"fc28cc53faf8eed74c569c9cbb0858fec3bc8d8c40bcd1670596e1301d19de48","SHA512Sum":"ebd58f3de492e42c618def45f02b0e08242b31f5808a6d9c3250f2a811e2b7ff33bd341e02b501318249f50373c5a27af95d46988e9ac6666fce6628fdbc71de"}],"ComponentSizeInKB":22084,"CompsigList":["cp072379.compsig"],"FileList":["cp072379.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072379.exe","SHA1Sum":"cb40bcc93f55bfe5c33f436034d96954b099aafa","SHA256Sum":"fc28cc53faf8eed74c569c9cbb0858fec3bc8d8c40bcd1670596e1301d19de48","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.0.10"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_800b0edf4bbe46f888be289c6a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070906.zip","SHA1Sum":"895f07a386d908cd9b52be454b65bbfdf02c555b","SHA256Sum":"8db5ab0a0198d619cd4fb4e20ef27f1dbc47ecb5dfdd72d4d012879c5a12589b","SHA512Sum":"04ec9d65dd55834baa688ede36760048422c21128be0f5f5116b94c9aec35da1f746a69ec4f0e7059dd708a167e1031d3711f29bdcb83c8da9f3c77914cdbf6a"}],"ComponentSizeInKB":26252,"CompsigList":["CP070906.compsig"],"FileList":["/CP070906_BUILD_4.data","/CP070906.vmexe64","/CP070906.vmfile","/CP070906_VMw.zip","/CP070906.xml","/payload.json","/CP070906_VMw.zip/index.xml","/CP070906_VMw.zip/vendor-index.xml","/CP070906_VMw.zip/metadata.zip","/CP070906_VMw.zip/vib20/CP070906/HPE_bootbank_CP070906_HPG3.4-8.0.0.20613240.vib","/CP070906_VMw.zip/metadata.zip/vendor-index.xml","/CP070906_VMw.zip/metadata.zip/vmware.xml","/CP070906_VMw.zip/metadata.zip/vibs/CP070906--8050592796358486694.xml","/CP070906_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070906_HPG3.4-8.0.0.20613240.xml"],"Name":"CP070906.zip","SHA1Sum":"895f07a386d908cd9b52be454b65bbfdf02c555b","SHA256Sum":"8db5ab0a0198d619cd4fb4e20ef27f1dbc47ecb5dfdd72d4d012879c5a12589b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070906","Version":"HPG3.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_16bc02ecd29b4d0fba5f0cfb39","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070969.zip","SHA1Sum":"7fb069abbb275c17d1e9135b9a0103d8e4bfec52","SHA256Sum":"f911671c0b239b52509c740e19be1882371738ae0c1e9f7beee00d0d6a7687eb","SHA512Sum":"4c389e8f5e691a70e48b1b793b7bbd0a9c196a975b3c9e1a2355b91dfea763d18e1b555ac717ac8a09f410ce38df0d4c6fd05e849e36c8407d67111ffead473b"}],"ComponentSizeInKB":20121,"CompsigList":["CP070969.compsig"],"FileList":["/CP070969_BUILD_1.data","/CP070969.vmexe64","/CP070969.vmfile","/CP070969_VMw.zip","/CP070969.xml","/payload.json","/CP070969_VMw.zip/index.xml","/CP070969_VMw.zip/vendor-index.xml","/CP070969_VMw.zip/metadata.zip","/CP070969_VMw.zip/vib20/CP070969/HPE_bootbank_CP070969_HPG1.1-8.0.0.20613240.vib","/CP070969_VMw.zip/metadata.zip/vendor-index.xml","/CP070969_VMw.zip/metadata.zip/vmware.xml","/CP070969_VMw.zip/metadata.zip/vibs/CP070969--2651863413044444403.xml","/CP070969_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070969_HPG1.1-8.0.0.20613240.xml"],"Name":"CP070969.zip","SHA1Sum":"7fb069abbb275c17d1e9135b9a0103d8e4bfec52","SHA256Sum":"f911671c0b239b52509c740e19be1882371738ae0c1e9f7beee00d0d6a7687eb","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070969","Version":"HPG1.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_862465ab528a4e0ba0eb360245","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3231-3030-304a5945534e","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3631-3030-304a59455643","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3032-3030-304a59455644","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Summit_SUMMITSUSND3.fwpkg","SHA1Sum":"7f2b1192df02cde396e7efcb7c3674f0fddc652d","SHA256Sum":"1452e5d30ef9fa05e95baf7a678ccc8829560d560eea739188b9812298215723","SHA512Sum":"ef0fbebe30bd3b39dc37fb7deba9d1d26840978ece723b1ce93762ca990009783b261d496e1a695834271d7bfc45ba9b476ba9b2e4ae2c5721d929e1fa713fe4"}],"ComponentSizeInKB":3682,"CompsigList":[],"FileList":["payload.json","Seagate_Summit_SUMMITSUSND3.HPb","Seagate_Summit_SUMMITSUSND3.xml"],"Name":"Seagate_Summit_SUMMITSUSND3.fwpkg","SHA1Sum":"7f2b1192df02cde396e7efcb7c3674f0fddc652d","SHA256Sum":"1452e5d30ef9fa05e95baf7a678ccc8829560d560eea739188b9812298215723","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB12000JYESN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB16000JYEVC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB20000JYEVD","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_83ab6972351c42d3b0ce1fc4cf","SupportedDevices":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u44-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"42b7708c02d146063adf73ade95d4e78d9385d7c","SHA256Sum":"36f93ce5bc9af43fd08b63adf95e7583c179aebaedcc23f2afcd712ed7a726a7","SHA512Sum":"ab4ac200f4facc2dd05e38fad487e2e9fd48bac5961879915e2cb38e61facf65d2a47c3a5c04df52fdeb96b543f4d8bcf8d21990f893510039ce9466b548a097"}],"ComponentSizeInKB":8742,"CompsigList":["firmware-system-u44-3.76_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/CP072039.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/U44_3.76_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072039.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072039.scexe"],"Name":"firmware-system-u44-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"42b7708c02d146063adf73ade95d4e78d9385d7c","SHA256Sum":"36f93ce5bc9af43fd08b63adf95e7583c179aebaedcc23f2afcd712ed7a726a7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fc949a58e3044ed6b20aa4c9b0","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","12.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071991.exe","SHA1Sum":"5012f93a40c4cbad2e5fee16bf1b861297643546","SHA256Sum":"3ee5db72af1e8295aa353cd17cec8ef2853688587f15509edda4a77026f28a82","SHA512Sum":"bd7896e653109ffc3dc6117ca83622c9d7912aa8b058aaf61caa7060a458225d6b646019716e34b6b453de71457347e17ce37086066302bda579a5a043c1af21"}],"ComponentSizeInKB":678,"CompsigList":["cp071991.compsig"],"FileList":["cp071991.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"Name":"cp071991.exe","SHA1Sum":"5012f93a40c4cbad2e5fee16bf1b861297643546","SHA256Sum":"3ee5db72af1e8295aa353cd17cec8ef2853688587f15509edda4a77026f28a82","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.54"}],"InstallationDependency":{},"Name":"AMD PSHED Plug-in service for Microsoft Windows Server 2022 and 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d2b1724c510a4764bb242a2ef6","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A55","A56","A55","A56","A42","A42","A40","A42","A43","A43","A43","A41","A47","A48","A46","A58","HPE Cray XD295v","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-tg3-3.139y-1.rhel10u1.x86_64.rpm","SHA1Sum":"13c359aacde4720fd4d634286933c3dce1a28b86","SHA256Sum":"a5b29f71ff49e43e89bb03fa25cf05487171d31d19561cf706f84a7287cc6d73","SHA512Sum":"c8ab503be214b2361a9c11816dae1487d326eb3e81062b5c997f53a78a6a0905b6b87841f2dd2cd7c749b6460ea01a7d1d76a881ba79095c73fc966153daaba8"}],"ComponentSizeInKB":156,"CompsigList":["kmod-tg3-3.139y-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/9bfa13c4c959d93478b8f54f3d3056cbced9de","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.139y-1.rhel10u1.x86_64.rpm","SHA1Sum":"13c359aacde4720fd4d634286933c3dce1a28b86","SHA256Sum":"a5b29f71ff49e43e89bb03fa25cf05487171d31d19561cf706f84a7287cc6d73","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139y-1"},{"Checksum":[{"Filename":"kmod-tg3-3.139y-1.rhel10u0.x86_64.rpm","SHA1Sum":"64548c9f5c3286466ad576109bab9fd0a2377406","SHA256Sum":"c0f795dfb020cc1c1f51ee202c9337ff630ec575b245d2879ae97ad63a3796c9","SHA512Sum":"8a1fe36c2d698b211bf76788d2b5e957e78ea444e0e8fe20d1a6c22d3605ed24da9a3eccda28ea86d68e290a9104580853ca208c9fa47bb512de1e23ef445fda"}],"ComponentSizeInKB":157,"CompsigList":["kmod-tg3-3.139y-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/tg3","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/96","./usr/lib/.build-id/96/592bd64ca708cae65e3f2d8f04400073e45532","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.139y-1.rhel10u0.x86_64.rpm","SHA1Sum":"64548c9f5c3286466ad576109bab9fd0a2377406","SHA256Sum":"c0f795dfb020cc1c1f51ee202c9337ff630ec575b245d2879ae97ad63a3796c9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139y-1"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4b6a33b4d035415cac4adcce14","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","U68","U72","U70","A66","A66","03030202","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_XXV4T_O_SEC_4p91_PLDMoMCTP_800214B1.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4T_O_SEC_4p91_PLDMoMCTP_800214B1.fwpkg","SHA1Sum":"9600badb60b8b0284ceaa33914e6e06b7077f321","SHA256Sum":"48f52bc8c4be4706e05193836c70d87719d19482dd419b5febcd58ec215297fb","SHA512Sum":"482afdf6550af855454ebb4e845336b9ae4dfa7ce3c7b2d5ffa8a7f7772a9fe51a5202e7fe771d0d9ee70fff9770f54b9d2e55a2a46791fed474dfbfb5a3ff46"}],"ComponentSizeInKB":10278,"CompsigList":[],"FileList":["HPE_E810_XXV4T_O_SEC_4p91_PLDMoMCTP_800214B1.HPb","HPE_E810_XXV4T_O_SEC_4p91_PLDMoMCTP_800214B1.xml","payload.json"],"Name":"HPE_E810_XXV4T_O_SEC_4p91_PLDMoMCTP_800214B1.fwpkg","SHA1Sum":"9600badb60b8b0284ceaa33914e6e06b7077f321","SHA256Sum":"48f52bc8c4be4706e05193836c70d87719d19482dd419b5febcd58ec215297fb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90afaf91d183433597dbb4d307","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068888.exe","SHA1Sum":"827f742c219dfc6a61294860030105cf27e90c96","SHA256Sum":"78110d11e362bb15d619a2ac085176f8a3121dfe249f9a8b80830933e8f01254","SHA512Sum":"35e445e7351533b476f777aa4a72b5a37a3082dd846f95ec5bf91449561398ee898e460528dad07c8555427ce4cd83823ce601ed1f5d0aef51ab3c5fa3def03c"}],"ComponentSizeInKB":3095,"CompsigList":["cp068888.compsig"],"FileList":["cp068888.xml","cpqsetup.exe","cp_data.xml","install.xml","multisetup.dll","StorCLI.msi"],"Name":"cp068888.exe","SHA1Sum":"827f742c219dfc6a61294860030105cf27e90c96","SHA256Sum":"78110d11e362bb15d619a2ac085176f8a3121dfe249f9a8b80830933e8f01254","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"TypeOfChange":"1","Version":"7.3604.0.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"storcli64.exe","SWKeyExpectedPath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_025dcd5ad1234463a055d4da8b","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","SHA1Sum":"595a0eb2302237a16f49dfbd798aeae8368ab6bf","SHA256Sum":"a75f21aca37d7f6a11a7d5b1d6c5086c82667593bf09f8b714ec4ff22f732b91","SHA512Sum":"e353a70c1bc074907f0b5683b9f523d1df323bee1302ec378c22caa2f37fa9d5f18bb39c0b20d4997b4bc49d2eaac4dad8e6302bdc4239f35be6955c9756cab4"}],"ComponentSizeInKB":6385,"CompsigList":["firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/CP068925.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068925.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068925.scexe"],"Name":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","SHA1Sum":"595a0eb2302237a16f49dfbd798aeae8368ab6bf","SHA256Sum":"a75f21aca37d7f6a11a7d5b1d6c5086c82667593bf09f8b714ec4ff22f732b91","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f99825a1487a46a4b05ef9db9b","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068814.zip","SHA1Sum":"c6446fb73de963548d44c667c48215d53d32d400","SHA256Sum":"880abbae87e78e1e7e417024198fd195505b487a17ac77cec3ab1870fb66e8bd","SHA512Sum":"e2f7e422ae0f0056181beef2ac60601a0a588ed17bb53c9ed0aee373ac9f59bae3a2bbeedced7a3d84bc5855e1f181f0ca956533df5eb93d94e7d04bff57f88e"}],"ComponentSizeInKB":901,"CompsigList":["cp068814.compsig"],"FileList":["/cp068814.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/vib20/icen/INT_bootbank_icen_2.3.3.0-1OEM.800.1.0.20613240.vib","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/icen-1592084883171535676.xml","/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-icen_2.3.3.0-1OEM.800.1.0.20613240.xml"],"Name":"cp068814.zip","SHA1Sum":"c6446fb73de963548d44c667c48215d53d32d400","SHA256Sum":"880abbae87e78e1e7e417024198fd195505b487a17ac77cec3ab1870fb66e8bd","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"icen","Version":"2.3.3.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.3.3.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.3.3.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21aa2066d8ea4cb6b8ed6a9cb6","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u43-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"108e46a8d61ac7818cf07ecc1b718847ba816637","SHA256Sum":"7000699fc2b5e792004931da7451a2199614f92701df3df7730d489f2c26371d","SHA512Sum":"37a9fed6899f439985e28653cd623464865a7080bed6bb6d34c51e97f8c9c0d87cbf7f3a51ce8b2d9562b36fbafaf1b82f5b888ee54447e9da782d947bdcd6b1"}],"ComponentSizeInKB":8728,"CompsigList":["firmware-system-u43-3.76_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/CP072030.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/U43_3.76_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072030.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072030.scexe"],"Name":"firmware-system-u43-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"108e46a8d61ac7818cf07ecc1b718847ba816637","SHA256Sum":"7000699fc2b5e792004931da7451a2199614f92701df3df7730d489f2c26371d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a572ec5bb5af4115a450a56483","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","12.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","SHA1Sum":"dba0b59c9a99ba00af0a63b0796a04f0b4707d1b","SHA256Sum":"6f0f7ddbf954db11bfac41e02bda371373371c79711631462591ac9ec6bbe591","SHA512Sum":"796af13fde2ba57587090aec50580653c5ce8a5f1a6c000cbfc04c0a6e837998b063fc119ad4277fc1ad7463f789908bcc5e9acfa4a51dee731f4dc9e4e38361"}],"ComponentSizeInKB":9663,"CompsigList":["firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/CP068912.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/MPK78H5Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068912.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068912.scexe"],"Name":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","SHA1Sum":"dba0b59c9a99ba00af0a63b0796a04f0b4707d1b","SHA256Sum":"6f0f7ddbf954db11bfac41e02bda371373371c79711631462591ac9ec6bbe591","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1070be9bbbed4c4086fa6ad674","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3830-3048d90154e8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068761.exe","SHA1Sum":"0b28732d2c1fdb1eec129fb44593983d1d82837f","SHA256Sum":"615cbe017d733f7b1ef0f76ea738d25cae6aa6c8b67bb57314a56fcd128cf356","SHA512Sum":"9cbaa79ea31ebbb01c31d34ce37fdb3ccdac3bb5066d19e46666b391ded03600dd9cf806695aa7ad18dc64561e2097cd45a697910483adcf5bfce86f9cbb37e5"}],"ComponentSizeInKB":3173,"CompsigList":["cp068761.compsig"],"FileList":["cp068761.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXn0HPD9.REL"],"Name":"cp068761.exe","SHA1Sum":"0b28732d2c1fdb1eec129fb44593983d1d82837f","SHA256Sum":"615cbe017d733f7b1ef0f76ea738d25cae6aa6c8b67bb57314a56fcd128cf356","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_636289ed1ad14379824d9cf5ca","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"cp068758.exe","SHA1Sum":"07290ec52eb31aad45ff534799d97d338017761d","SHA256Sum":"51db9e68ced18af9c6daf2b521a63ec310c8034043ba14a94e7173b85207fb58","SHA512Sum":"a6c960a1bdae82255072b8d3d0a9746c0a27cbb400a6ebdf2aa41c3caa2e0fb515c25afc644705e47837dbbb20cab55e4a210c497afe63bd19ed919714477377"}],"ComponentSizeInKB":3919,"CompsigList":["cp068758.compsig"],"FileList":["cp068758.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08scHPDC.rel"],"Name":"cp068758.exe","SHA1Sum":"07290ec52eb31aad45ff534799d97d338017761d","SHA256Sum":"51db9e68ced18af9c6daf2b521a63ec310c8034043ba14a94e7173b85207fb58","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_82fb0e5310174d9195ce89abea","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068651.exe","SHA1Sum":"00f8df909caf978c384b83369e378268dc55b972","SHA256Sum":"5176dbc041c20cd64475c4a2fbfcd8985b798dc59c6193a67b36d9580c81f5eb","SHA512Sum":"75b584c255f602527a24c376b780652153c688d8ae99c477e50e9b0acf4b65388e6539eb34bcef6338eff477772d3cd877035ced71ccc4a09bf36a2d6f1b7dd5"}],"ComponentSizeInKB":4010,"CompsigList":["cp068651.compsig"],"FileList":["cp068651.xml","cpqsetup.exe","KAPM6ALFHPD4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068651.exe","SHA1Sum":"00f8df909caf978c384b83369e378268dc55b972","SHA256Sum":"5176dbc041c20cd64475c4a2fbfcd8985b798dc59c6193a67b36d9580c81f5eb","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_34f98f1102e24c1dbf193b4820","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","SHA1Sum":"fbb983282fb7826e440b017a2ade3149f0cb330a","SHA256Sum":"a2d0a41d8933e4bfc6c4effa8dd15dac4c49700f837e4caf2da9cfdc2da7f7c8","SHA512Sum":"27dcc5bf13c9f71f3be42216fc4f165e45fcb5cb10b2e043329cac5252acde9290ea4ed1c9b40d382e36e8172c5299a3e3e8bd4e0ab4b3d9420cdd8ccd1b4667"}],"ComponentSizeInKB":7216,"CompsigList":["firmware-hdd-54addf5312-HPK4-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/CP068906.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068906.scexe"],"Name":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","SHA1Sum":"fbb983282fb7826e440b017a2ade3149f0cb330a","SHA256Sum":"a2d0a41d8933e4bfc6c4effa8dd15dac4c49700f837e4caf2da9cfdc2da7f7c8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ebf0ab82df74654bb70a9bc31","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7f2a26e6d0-HPG1-14.1.x86_64.rpm","SHA1Sum":"6603c62464b7b5467e8ec59b8fd0e93d5ef6ad24","SHA256Sum":"2719683b7cbf8aa0df9dcb001985401f909e21bcd5c1b8ef56801ff55b4a2fb4","SHA512Sum":"9a3282b0210e94e17d2a43459dfc63b5bffc0930ca82f66ee08e7c854f91fad63f6748388486ec8761e1587df1336729f9c81234b12f88f2336e740765cb4710"}],"ComponentSizeInKB":6258,"CompsigList":["firmware-hdd-7f2a26e6d0-HPG1-14.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/CP068845.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068845.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068845.scexe"],"Name":"firmware-hdd-7f2a26e6d0-HPG1-14.1.x86_64.rpm","SHA1Sum":"6603c62464b7b5467e8ec59b8fd0e93d5ef6ad24","SHA256Sum":"2719683b7cbf8aa0df9dcb001985401f909e21bcd5c1b8ef56801ff55b4a2fb4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9b7922ea3a25464699d43072eb","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070551.exe","SHA1Sum":"2eb63b6d57eacf745d052cefaf1284685f81f420","SHA256Sum":"13fdea7250c1b17fe3e01f5229f0cbebdd68e05de32ef36d750bd067450b5b45","SHA512Sum":"2f4eb6ffb418ccac2c2641bfea805dde76b709c3678db6b1df5f54f14c0f2b08ae98f5cf2a43e285ffc1f63e4eed604af55670d0802dd1d0d8771c29369c675c"}],"ComponentSizeInKB":1385,"CompsigList":["cp070551.compsig"],"FileList":["cp070551.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp070551.exe","SHA1Sum":"2eb63b6d57eacf745d052cefaf1284685f81f420","SHA256Sum":"13fdea7250c1b17fe3e01f5229f0cbebdd68e05de32ef36d750bd067450b5b45","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.18.158.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc010a063557413cad2721dc60","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","SHA1Sum":"14895babd87a1d3beeb4903dad329d8ba7c64aa7","SHA256Sum":"9568457a6d9c1c2bc2bf74ca65f0ad62bafa269e08a1f5cbaa296c074e2f65cf","SHA512Sum":"1a66a8cd84a00de0cca7eb4d00e06d959b7a28ffe2b764e2d7c9c9c99bb94c444d9e9356e6e3fb103d88308f3132e0d35b8a0e5272556309cc193d4eaf4c500e"}],"ComponentSizeInKB":5039,"CompsigList":["firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/CP068857.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068857.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068857.scexe"],"Name":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","SHA1Sum":"14895babd87a1d3beeb4903dad329d8ba7c64aa7","SHA256Sum":"9568457a6d9c1c2bc2bf74ca65f0ad62bafa269e08a1f5cbaa296c074e2f65cf","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_026217c0626d4029b3c39b733e","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.10"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.10"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.10"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.10"}]},"Files":[{"Checksum":[{"Filename":"cp070314.exe","SHA1Sum":"fe1e4fc07ddf1a2d699bc804d447496cc2d8c9d9","SHA256Sum":"fd049eb53434c87eadbc58bcdbb233123a5ec058e9081d0547e6c4778e09aa10","SHA512Sum":"f120d13953e368bcfb82e6352ce2f64beaae79d820d605a397e2f85938b07d2021f782acd19f6658dd7dae6e2ad52b47eaa5cf1a8670b56ae2531b472eba4dfa"}],"ComponentSizeInKB":4495,"CompsigList":["cp070314.compsig"],"FileList":["cp070314.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.10-1/firmware/","elxflashStandalone-windows-14.4.731.10-1/firmware/B1447315.grp","elxflashStandalone-windows-14.4.731.10-1/firmware/P14473110.grp","elxflashStandalone-windows-14.4.731.10-1/win/","elxflashStandalone-windows-14.4.731.10-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.10-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.10-1/win/x64/","elxflashStandalone-windows-14.4.731.10-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.10-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.10-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.10-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.10-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.10-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.10-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp070314.exe","SHA1Sum":"fe1e4fc07ddf1a2d699bc804d447496cc2d8c9d9","SHA256Sum":"fd049eb53434c87eadbc58bcdbb233123a5ec058e9081d0547e6c4778e09aa10","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.04.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2025 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_972da401be134113a5b3e69266","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U44_3.76_05_28_2026.fwpkg","SHA1Sum":"d45f05e1f405da0c05411147c993f70dc67c3271","SHA256Sum":"ac1a67a39d9c7440cfaf9dc9c36334727d8c6ba90a70677f7579cd4b016c2ef2","SHA512Sum":"e32f071724bfdbfbe5cd4a31c02ca87f0d4e6ce6f8807d7de70868bcf52ff1d43997553217e894600fddc2117b838ee8c14ba3aede8a6e4ed1a042e35f3422cc"}],"ComponentSizeInKB":16430,"CompsigList":[],"FileList":["payload.json","U44_3.76_05_28_2026.signed.flash","U44_3.76_05_28_2026.xml"],"Name":"U44_3.76_05_28_2026.fwpkg","SHA1Sum":"d45f05e1f405da0c05411147c993f70dc67c3271","SHA256Sum":"ac1a67a39d9c7440cfaf9dc9c36334727d8c6ba90a70677f7579cd4b016c2ef2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b67e14c5d79b416eb65938030b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069545.exe","SHA1Sum":"c498c79eb1547160c6711959e62f3f62de7048e9","SHA256Sum":"2b221c1557aa85cabc16e6d1feb002a2b5f526e102ff0d556887575e26d5524c","SHA512Sum":"6f4b0efef83bd447f33cf183498ea8e36519ef10048bd6cb1fdf47255610dfb91d9b7769915aa8c699b052c198e22ebba81ea2a10677a314da000c0601ff8e8e"}],"ComponentSizeInKB":1054,"CompsigList":["cp069545.compsig"],"FileList":["cp069545.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069545.exe","SHA1Sum":"c498c79eb1547160c6711959e62f3f62de7048e9","SHA256Sum":"2b221c1557aa85cabc16e6d1feb002a2b5f526e102ff0d556887575e26d5524c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc3de517782147afa79bbf057e","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069724.exe","SHA1Sum":"41e290186c1c75152ea7bad3c8ab2389e33d098d","SHA256Sum":"6cb66d60b8b19fea7f1dd6b1395482b809e7914a9dd69797436fe2431d9d5a87","SHA512Sum":"f1e8ca3f1876baab9103173b20e0c54ba35828db555bfd382adba303ad09bc3cbb0132a8e5ecc761598cd524fbce6f13bb1ae55120b2a2039222a4175b192d46"}],"ComponentSizeInKB":572,"CompsigList":["cp069724.compsig"],"FileList":["cp069724.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp069724.exe","SHA1Sum":"41e290186c1c75152ea7bad3c8ab2389e33d098d","SHA256Sum":"6cb66d60b8b19fea7f1dd6b1395482b809e7914a9dd69797436fe2431d9d5a87","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.2.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\necheschif.inf_amd64_e49bd7dc444fc00f"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54d504f6c59f4fa29b42a809d8","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","I44","U46","U46","U47","U47","U50","H08","H08","H10","H10","H10","U60","U61","U56","A42","A43","A43","A42","A48","U50","U39","U40","U64","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068770.exe","SHA1Sum":"92f52c9381b9436b2fd927590fc06d003dcbfd06","SHA256Sum":"cfc1cb5428ff669cb4b07da4083dd5f626452f761dc995d7f1300595684fee38","SHA512Sum":"764d1517488c63111d8f3d850790c6ee2ccd9898a2590fc06f5a9b138ca2ca94cc9cd9e48c53ddf4093114532998e56d05d4e85e5dd07b440c98e13ed4be1978"}],"ComponentSizeInKB":3902,"CompsigList":["cp068770.compsig"],"FileList":["cp068770.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08acHPG5.REL"],"Name":"cp068770.exe","SHA1Sum":"92f52c9381b9436b2fd927590fc06d003dcbfd06","SHA256Sum":"cfc1cb5428ff669cb4b07da4083dd5f626452f761dc995d7f1300595684fee38","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1bb16f5a976f41e0bd3d2e4fe9","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068732.exe","SHA1Sum":"14a4746062f03892b84c4878b54e427eafb748f8","SHA256Sum":"bb6a32ec52e008529f825ef04711a2ab21eed48b735fbd7a6ad503c5314c7aef","SHA512Sum":"dee0482413e1ab4f577167950bdb7e6d5b55ca46fb5cf31f44064fd924cb4c95beee342e2a2d64500704a4546acaf279f7e9779607c2d121c9b207db01ee0899"}],"ComponentSizeInKB":4098,"CompsigList":["cp068732.compsig"],"FileList":["cp068732.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNSD8.rel","setup.dll"],"Name":"cp068732.exe","SHA1Sum":"14a4746062f03892b84c4878b54e427eafb748f8","SHA256Sum":"bb6a32ec52e008529f825ef04711a2ab21eed48b735fbd7a6ad503c5314c7aef","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5d391774ceff44a2a6b208614f","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U64_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u64-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"45b0c6dbed1dd2c9bbcb7b53c5a9868d995c51a4","SHA256Sum":"6b12409cee8cd2b48510d5651b932d8c34df549f2582e0f189d9686aa46a8a8b","SHA512Sum":"e1eab4ae737b076e46d99a83e96d21bb58ba6b3163dc4d7308138f0a69ce3c5ad57830645a161e5edae28710d90536a174a9b4d2ffad11f3ef0638446b59f1ea"}],"ComponentSizeInKB":16715,"CompsigList":["firmware-system-u64-2.64_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/CP071354.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/U64_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071354.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071354.scexe"],"Name":"firmware-system-u64-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"45b0c6dbed1dd2c9bbcb7b53c5a9868d995c51a4","SHA256Sum":"6b12409cee8cd2b48510d5651b932d8c34df549f2582e0f189d9686aa46a8a8b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f788a2ca6c5f4f248be3dba942","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304759444e4c","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304759445045","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304759444e4e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","SHA1Sum":"842440cd46a3b456897604f5efb5a636c98ce85d","SHA256Sum":"1380d55773ddcd4828e2d6388a5be330499d38c17c8d9ba9a58c4ef2c4c4df1c","SHA512Sum":"20cbb8d97053d1835429befc0de740aa69f5145d465d6f888a5321e7d74f0d22d70dc480d7ac87aedda1f382e3fe77fa798202ba30e98314a9154644585e0ca8"}],"ComponentSizeInKB":2562,"CompsigList":[],"FileList":["payload.json","Seagate_CimarronBP_SCIMARBPETG4.HPb","Seagate_CimarronBP_SCIMARBPETG4.xml"],"Name":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","SHA1Sum":"842440cd46a3b456897604f5efb5a636c98ce85d","SHA256Sum":"1380d55773ddcd4828e2d6388a5be330499d38c17c8d9ba9a58c4ef2c4c4df1c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GYDNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GYDPE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB010000GYDNN","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0be86abeb599456ea5c1845fc6","SupportedDevices":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068643.exe","SHA1Sum":"27cdd8ba2913c36c149dbd12fe2c97971b68564b","SHA256Sum":"c3b24244cd3265f4a995f24e5543a009d6d7f1b5336b5d7e4f572e9f32e97571","SHA512Sum":"e714053d96d16ced8c7637498dc550d104c630fed8b54882624b94e4025e2ef0d242a97906b0beb34b66e8f6ff918e06c919174a4ffbaf03af4c42b3c944130c"}],"ComponentSizeInKB":4832,"CompsigList":["cp068643.compsig"],"FileList":["cp068643.xml","cpqsetup.exe","HPG1PM893.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068643.exe","SHA1Sum":"27cdd8ba2913c36c149dbd12fe2c97971b68564b","SHA256Sum":"c3b24244cd3265f4a995f24e5543a009d6d7f1b5336b5d7e4f572e9f32e97571","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a8c1c0fb65e04e15a97628a36f","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070932.zip","SHA1Sum":"895f6580a5b1e69fcbae9b58759d7d1a039427f0","SHA256Sum":"34b9b706d4d4c1747b2bda877f5be15e891281353385483a2747b71e647ea06b","SHA512Sum":"f0aa00b3919584ff7fe55d618ddfa02d797e3e300a3b785bd8d33e67081fba297dd29c4e6346eadd6360a2217420a7b34fb7ed7f41469f089e1d03fbb55f82aa"}],"ComponentSizeInKB":19788,"CompsigList":["CP070932.compsig"],"FileList":["/CP070932_BUILD_6.data","/CP070932.vmexe64","/CP070932.vmfile","/CP070932_VMw.zip","/CP070932.xml","/payload.json","/CP070932_VMw.zip/index.xml","/CP070932_VMw.zip/vendor-index.xml","/CP070932_VMw.zip/metadata.zip","/CP070932_VMw.zip/vib20/CP070932/HPE_bootbank_CP070932_HPD9.6-8.0.0.20613240.vib","/CP070932_VMw.zip/metadata.zip/vendor-index.xml","/CP070932_VMw.zip/metadata.zip/vmware.xml","/CP070932_VMw.zip/metadata.zip/vibs/CP070932--6898642298238919011.xml","/CP070932_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070932_HPD9.6-8.0.0.20613240.xml"],"Name":"CP070932.zip","SHA1Sum":"895f6580a5b1e69fcbae9b58759d7d1a039427f0","SHA256Sum":"34b9b706d4d4c1747b2bda877f5be15e891281353385483a2747b71e647ea06b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070932","Version":"HPD9.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e65e99be2f1e46d5ace29d27d4","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-abd133f0de_0HPG1-2.1_amd64.deb","SHA1Sum":"8ad0d130d68affb7fadc15b370960366ecc8e020","SHA256Sum":"c093a99faf5dfc13354d736202eef25a9b3fa5629a015af6ea61abb9f17c6a7e","SHA512Sum":"c12afaac06bc960b9e31d24704965b4a276c642efa60507673de6eab36354ab6bbdee870012f7d6f3ead165a54162d5d1bfaeeb061bdcb73401fa072bf79e035"}],"ComponentSizeInKB":5082,"CompsigList":["firmware-hdd-abd133f0de_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/CP071810.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/HPG1PM893.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071810.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071810.scexe"],"Name":"firmware-hdd-abd133f0de_0HPG1-2.1_amd64.deb","SHA1Sum":"8ad0d130d68affb7fadc15b370960366ecc8e020","SHA256Sum":"c093a99faf5dfc13354d736202eef25a9b3fa5629a015af6ea61abb9f17c6a7e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1f67021e4f1d49838ef1fc29ea","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-805abb7e9c_85032G00-2.1_amd64.deb","SHA1Sum":"e851c54c4a156d727bc1b4b08a473578bebab14d","SHA256Sum":"134c35b1c8178070c073adce920491d21222f6a1069b7c45a55172f1ea086d61","SHA512Sum":"aa39b6bc6f7973cd1ce5f830233c458b75729b01ce86433e276d1d76eaa02bde514f245728942333845a86c8b53b9ef453f543795f1c4e00ecfe95032e8b8d28"}],"ComponentSizeInKB":3933,"CompsigList":["firmware-hdd-805abb7e9c_85032G00-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/CP071757.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071757.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071757.scexe"],"Name":"firmware-hdd-805abb7e9c_85032G00-2.1_amd64.deb","SHA1Sum":"e851c54c4a156d727bc1b4b08a473578bebab14d","SHA256Sum":"134c35b1c8178070c073adce920491d21222f6a1069b7c45a55172f1ea086d61","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4003352b072144f088efb2cf49","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Files":[{"Checksum":[{"Filename":"CP070394.zip","SHA1Sum":"21b137a38840ebfcb4527e24b4b2247f090dfd66","SHA256Sum":"6af1ca5f6df5c2af3d4802ef51f7ca85d193c1d2628bb98703ec9fcefecd47a1","SHA512Sum":"3b9a208a70acda4b84d22390a4b7d83254496ff91262bf56c2cf8b1bad2819ebbbae62686c49f3fe1acd7b35704fb0de7901c6a3ea04525626d4b1c59356373d"}],"ComponentSizeInKB":12444,"CompsigList":["CP070394.compsig"],"FileList":["/CP070394_BUILD_4.data","/CP070394.vmexe64","/CP070394.vmfile","/CP070394_VMw.zip","/CP070394.xml","/payload.json","/CP070394_VMw.zip/index.xml","/CP070394_VMw.zip/vendor-index.xml","/CP070394_VMw.zip/metadata.zip","/CP070394_VMw.zip/vib20/CP070394/HPE_bootbank_CP070394_1.37.0.4-8.0.0.20613240.vib","/CP070394_VMw.zip/metadata.zip/vendor-index.xml","/CP070394_VMw.zip/metadata.zip/vmware.xml","/CP070394_VMw.zip/metadata.zip/vibs/CP070394-8154619211798709556.xml","/CP070394_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070394_1.37.0.4-8.0.0.20613240.xml"],"Name":"CP070394.zip","SHA1Sum":"21b137a38840ebfcb4527e24b4b2247f090dfd66","SHA256Sum":"6af1ca5f6df5c2af3d4802ef51f7ca85d193c1d2628bb98703ec9fcefecd47a1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"1.37.0","VibList":[{"Name":"CP070394","Version":"1.37.0.4-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5fc62ff1e7c24488af146495f2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"237.1.148000"}]},"Files":[{"Checksum":[{"Filename":"CP071468.zip","SHA1Sum":"2aff97f2fc004e2105a26edca348db890849b74d","SHA256Sum":"fba1c739afdd3f960fe92a466d6ac56340e4aa63e8e1c1be58ab067e987e2cfa","SHA512Sum":"dcfb07241f09883866a5d793c56f938bee4dc30a8014111c992a8e187b64ed4365f9bcac44c96fe2b1fdf1d9b4f4368738d8407c59a80e107e5840aa13b7cff2"}],"ComponentSizeInKB":16249,"CompsigList":["CP071468.compsig"],"FileList":["/CP071468_BUILD_1.data","/CP071468.vmexe64","/CP071468.vmfile","/CP071468_VMw.zip","/CP071468.xml","/payload.json","/CP071468_VMw.zip/index.xml","/CP071468_VMw.zip/vendor-index.xml","/CP071468_VMw.zip/metadata.zip","/CP071468_VMw.zip/vib20/CP071468/HPE_bootbank_CP071468_5.28.0.1-8.0.0.20613240.vib","/CP071468_VMw.zip/metadata.zip/vendor-index.xml","/CP071468_VMw.zip/metadata.zip/vmware.xml","/CP071468_VMw.zip/metadata.zip/vibs/CP071468--8403381684488150275.xml","/CP071468_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071468_5.28.0.1-8.0.0.20613240.xml"],"Name":"CP071468.zip","SHA1Sum":"2aff97f2fc004e2105a26edca348db890849b74d","SHA256Sum":"fba1c739afdd3f960fe92a466d6ac56340e4aa63e8e1c1be58ab067e987e2cfa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.28.0","VibList":[{"Name":"CP071468","Version":"5.28.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6c5ec745e56842968deb5db9bc","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U47_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U47_2.64_04_01_2026.fwpkg","SHA1Sum":"223ee45076404722db65b6fd3742a6a746c52843","SHA256Sum":"d27490205b48044840e11d9556d2352c6fe1b0c2b1870fbce014b567e1c6aef1","SHA512Sum":"f81cb72d8858aef9e36b39acdc0c15e705aed8ee83376a029f78efe8a0b351dc2d6c777902cd6f0b934db508d98a748ffebf99d7507b04fd418fdd69fa847380"}],"ComponentSizeInKB":32815,"CompsigList":[],"FileList":["payload.json","U47_2.64_04_01_2026.signed.flash","U47_2.64_04_01_2026.xml"],"Name":"U47_2.64_04_01_2026.fwpkg","SHA1Sum":"223ee45076404722db65b6fd3742a6a746c52843","SHA256Sum":"d27490205b48044840e11d9556d2352c6fe1b0c2b1870fbce014b567e1c6aef1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_01fcaf3c98954cd9bc6c58f642","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U47","U47"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U47_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071371.exe","SHA1Sum":"5b308fe466ff8b8b01edb724fb3eb32af9eb9d92","SHA256Sum":"3d7e4d307d86081b5455c3e12a97c0990e87f924b9072e63cc1b7d1f3c69da4d","SHA512Sum":"8b9aa69b1ea599489d7585e97995eb355a242dd6b0d42293b40dd1fdf4d4f977df701d4bfbe36d655b6304290895f99fe1d6a4ec066a75372de7871d747a0df7"}],"ComponentSizeInKB":33438,"CompsigList":["cp071371_part1.compsig","cp071371_part2.compsig"],"FileList":["cp071371.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U47_2.64_04_01_2026.signed.flash"],"Name":"cp071371.exe","SHA1Sum":"5b308fe466ff8b8b01edb724fb3eb32af9eb9d92","SHA256Sum":"3d7e4d307d86081b5455c3e12a97c0990e87f924b9072e63cc1b7d1f3c69da4d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_217887731c994c0185ea778f2e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U47","U47","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-30505a57534c","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-30505a57534e","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-30505a575350","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-30505a584642","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-30505a584555","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM165X_GPM1653SAMD4.fwpkg","SHA1Sum":"3e486a890f623ff9eb2aa10cb1c42554675bd7a9","SHA256Sum":"35feb07648f869b17ebe0c4406d5c1d0aec7cf665a48250be9663162ddb20aeb","SHA512Sum":"6847ff9e59d2bf533a5b81090d2fd41790e79be1f5209a19ccc8c68730845552e9816df0e5bd0ad9ba4326645b508ed7f091877ef49e8c8954600f5f3fc4cea9"}],"ComponentSizeInKB":1948,"CompsigList":[],"FileList":["payload.json","Samsung_PM165X_GPM1653SAMD4.HPb","Samsung_PM165X_GPM1653SAMD4.xml"],"Name":"Samsung_PM165X_GPM1653SAMD4.fwpkg","SHA1Sum":"3e486a890f623ff9eb2aa10cb1c42554675bd7a9","SHA256Sum":"35feb07648f869b17ebe0c4406d5c1d0aec7cf665a48250be9663162ddb20aeb","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960PZWSL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PZWSN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PZWSP","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PZXFB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PZXEU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ddbc160c7a4b4f22b8db349e39","SupportedDevices":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070968.zip","SHA1Sum":"88e7403e3dcdba2a79b9bb61f660d50b05779502","SHA256Sum":"caf9d8a94f31a818edbd024ceaf4d441ce78eda4897eb711e6cb2ccc82ed659d","SHA512Sum":"c94756867b218d1bc9b7ce8a4df738eb242420a8af42864013064d57e2ae3c8739541b71b5cbad731bf566b2aa595e595e60174125f0499192603c1c11379535"}],"ComponentSizeInKB":20163,"CompsigList":["CP070968.compsig"],"FileList":["/CP070968_BUILD_2.data","/CP070968.vmexe64","/CP070968.vmfile","/CP070968_VMw.zip","/CP070968.xml","/payload.json","/CP070968_VMw.zip/index.xml","/CP070968_VMw.zip/vendor-index.xml","/CP070968_VMw.zip/metadata.zip","/CP070968_VMw.zip/vib20/CP070968/HPE_bootbank_CP070968_HPG1.2-8.0.0.20613240.vib","/CP070968_VMw.zip/metadata.zip/vendor-index.xml","/CP070968_VMw.zip/metadata.zip/vmware.xml","/CP070968_VMw.zip/metadata.zip/vibs/CP070968--8048726149447307406.xml","/CP070968_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070968_HPG1.2-8.0.0.20613240.xml"],"Name":"CP070968.zip","SHA1Sum":"88e7403e3dcdba2a79b9bb61f660d50b05779502","SHA256Sum":"caf9d8a94f31a818edbd024ceaf4d441ce78eda4897eb711e6cb2ccc82ed659d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070968","Version":"HPG1.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6ccf09463de448cbbb5bf9446f","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","SHA1Sum":"03e418dd9e18a64ca36a73dbe171e7f3025b27fb","SHA256Sum":"229c510bc0484c83a07d7565c164a30553463f4144cc94f6f51e23d39a39671c","SHA512Sum":"a71952a34d8f3227fcc874cf1a262cd2559637c1c3e7f045c229f93000755bf4e63b4d6fd0c5d1713713f387a4c5946e5c22f4edb1daadaa4986bb68d37a2f87"}],"ComponentSizeInKB":5794,"CompsigList":["firmware-hdd-3d97759111-HPDB-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/CP068928.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068928.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068928.scexe"],"Name":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","SHA1Sum":"03e418dd9e18a64ca36a73dbe171e7f3025b27fb","SHA256Sum":"229c510bc0484c83a07d7565c164a30553463f4144cc94f6f51e23d39a39671c","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_de21450efdd548ebb29ded49e6","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-iavf-kmp-default-4.13.20_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"f6de43c6fadbe9987102001ce58f585494d03863","SHA256Sum":"72857e3c4f18b25b566cfbd615deee386a49e352096c18d07fa22308f4ee1dee","SHA512Sum":"e8849ae696e9b8f611da7eb23bec8af6287cab960845d461832f9d9ecbd6def6aff0302dca32d1f41e672852922e2151274e4426106a37ef0f8a6bd2b87d8fbb"}],"ComponentSizeInKB":183,"CompsigList":["hp-iavf-kmp-default-4.13.20_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"Name":"hp-iavf-kmp-default-4.13.20_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"f6de43c6fadbe9987102001ce58f585494d03863","SHA256Sum":"72857e3c4f18b25b566cfbd615deee386a49e352096c18d07fa22308f4ee1dee","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.20-1"},{"Checksum":[{"Filename":"hp-iavf-kmp-default-4.13.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"0ed9bafc329ef921d9e9f88b4f576d0854482d90","SHA256Sum":"a4ce21f8a2175a8915cf4cffaf4962d96747a403891ca90e612d3efb452d1f0c","SHA512Sum":"cb2ffa74250859910698f3eabb0b3cf129d330d43454bfa56d1a6926364c1feafe8ed4ed772325e2a2fcb0ae8e1942d207b6a9276401837a491495fe3292625f"}],"ComponentSizeInKB":183,"CompsigList":["hp-iavf-kmp-default-4.13.20_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"Name":"hp-iavf-kmp-default-4.13.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"0ed9bafc329ef921d9e9f88b4f576d0854482d90","SHA256Sum":"a4ce21f8a2175a8915cf4cffaf4962d96747a403891ca90e612d3efb452d1f0c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.20-1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"Name":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4822206d12a6446a94667a7ef0","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072404.zip","SHA1Sum":"dc3fa96c9d762aa6daa385aa6c79435df2bb97a0","SHA256Sum":"e754efa2d7f3485f654140cf2e8805c032b8a519bc3d25c3ba2486b8ab8cfe11","SHA512Sum":"0cd34e7d383f64ac664eaf114e4680ec0a72fc216e1a9327e83d7d07b7653549d084e3f8a9f8c21d10238fd67832ebd5557441e513d1fb6ffa8dff7aaa5da309"}],"ComponentSizeInKB":17947,"CompsigList":["CP072404.compsig"],"FileList":["/CP072404_BUILD_1.data","/CP072404.vmexe64","/CP072404.vmfile","/CP072404_VMw.zip","/CP072404.xml","/payload.json","/CP072404_VMw.zip/index.xml","/CP072404_VMw.zip/vendor-index.xml","/CP072404_VMw.zip/metadata.zip","/CP072404_VMw.zip/vib20/CP072404/HPE_bootbank_CP072404_HPG4.1-8.0.0.20613240.vib","/CP072404_VMw.zip/metadata.zip/vendor-index.xml","/CP072404_VMw.zip/metadata.zip/vmware.xml","/CP072404_VMw.zip/metadata.zip/vibs/CP072404-2651325455436991480.xml","/CP072404_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072404_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072404.zip","SHA1Sum":"dc3fa96c9d762aa6daa385aa6c79435df2bb97a0","SHA256Sum":"e754efa2d7f3485f654140cf2e8805c032b8a519bc3d25c3ba2486b8ab8cfe11","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072404","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36e2676305f04e409c8604c948","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.1","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.rpm","SHA1Sum":"38de33bbfa9e3531fa5b9c11c2df8d5cc6c1ebb4","SHA256Sum":"03b9ff5c69105fb44bd4ab696559ace0b1168bcac9cc12b5853959d9d3e26daa","SHA512Sum":"435e10725938d0294e7372d29f890975e6cc892aca46467373ee69fb930d5df0571d1a058561ca807351125221bdea2ab25902353c7a6142f3c9a83ad0f11b6d"}],"ComponentSizeInKB":79,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/56d9087076c17dba1b6619d764bb304de7b43e","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/bf648a8419210c90603ea1bd80200bd9170677","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.rpm","SHA1Sum":"38de33bbfa9e3531fa5b9c11c2df8d5cc6c1ebb4","SHA256Sum":"03b9ff5c69105fb44bd4ab696559ace0b1168bcac9cc12b5853959d9d3e26daa","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.rhel10u1.x86_64.rpm","SHA1Sum":"a62902960f2e92500f24b481e40c46c6537806cf","SHA256Sum":"139d525659bca95268dc2045a8812b9a1ef33d820127911b4dd2a449dbbc0fde","SHA512Sum":"44728181dd4c72d93d236ce86cf2f14f28ff8903d41e8891bf455ef53e472d2e0132ce543fa63acdf1e25b943683b9c3b8a95c30b0c51aef08e3998d9f6a7cb6"}],"ComponentSizeInKB":29822,"CompsigList":["mft-4.36.0-147.rhel10u1.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel10u1.x86_64.rpm","SHA1Sum":"a62902960f2e92500f24b481e40c46c6537806cf","SHA256Sum":"139d525659bca95268dc2045a8812b9a1ef33d820127911b4dd2a449dbbc0fde","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 10 Update 1 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f82b73bec6445349f439556e4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"cp068625.exe","SHA1Sum":"0bcbcd48753624ff53a395a5d159853e30363e3e","SHA256Sum":"4695f7465eec97b497cd6c7b1f01749178ac5829a5b6faeffb87c7590b3dc111","SHA512Sum":"95dd710bffc24b25aea6b3324a706580f973d82215c584ff3f122b950795816dd5868f9502e0a4afd551b08a024243cdb5ecefda9c5ac7f5f817ca10e458c49a"}],"ComponentSizeInKB":5335,"CompsigList":["cp068625.compsig"],"FileList":["cp068625.xml","cpqsetup.exe","KPE60X1GHPK4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068625.exe","SHA1Sum":"0bcbcd48753624ff53a395a5d159853e30363e3e","SHA256Sum":"4695f7465eec97b497cd6c7b1f01749178ac5829a5b6faeffb87c7590b3dc111","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_292d8b1e06bf4f8796fc78a8ed","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070842.zip","SHA1Sum":"c467b1051e81dc1d0d4a4f4dedee29f9b4b1a640","SHA256Sum":"96c5d6550de70a35c2cae59a4fc2f1e0aaab3c009b1b6b9ebb296bd72566156f","SHA512Sum":"02d48ac4bc31f23c1592e90e443499e81a574b9990d53618523921543294289bef784b8bb39251f7acffce71b0767446e20845e5da64748dee69109f391eb19d"}],"ComponentSizeInKB":5694,"CompsigList":["cp070842.compsig"],"FileList":["/cp070842.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070842.zip","SHA1Sum":"c467b1051e81dc1d0d4a4f4dedee29f9b4b1a640","SHA256Sum":"96c5d6550de70a35c2cae59a4fc2f1e0aaab3c009b1b6b9ebb296bd72566156f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d2f4f52013f54954a4084d8963","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"cp068645.exe","SHA1Sum":"9a3a29fd48c789bb108eeabe590b28c5db3d2691","SHA256Sum":"80b2098234f5ffbb9dbd3d2899b59fcbca686a97a037ad4d22cd3cccbca9b87d","SHA512Sum":"e903ceed6523ddba67ff5789f9db5bac172569b0d2f7e453583afbaa71a354358dabd85bfad41f77ede94b53f20176ae6b986ad9e6e09baac8a67bfcdf96bbdb"}],"ComponentSizeInKB":4326,"CompsigList":["cp068645.compsig"],"FileList":["cp068645.xml","cpqsetup.exe","KACD6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068645.exe","SHA1Sum":"9a3a29fd48c789bb108eeabe590b28c5db3d2691","SHA256Sum":"80b2098234f5ffbb9dbd3d2899b59fcbca686a97a037ad4d22cd3cccbca9b87d","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_11806acbfb014d739d8e94a6b5","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","SHA1Sum":"caed8742ed3070f3d8d75c5d401b41d2ffb7aa32","SHA256Sum":"395804142dcfc9ca7c0101a7d61f307ab725d632ac6417a3eb655e1ed873963a","SHA512Sum":"3eb943f9a5a448ec09904546b88bb7ae0bdb66e0d104c7704c49fe912474ab6076c855e28c675f9bc399625b50fbf09e4ca35a9382a864d7637126a661cb4e45"}],"ComponentSizeInKB":5738,"CompsigList":["firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/CP068852.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068852.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068852.scexe"],"Name":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","SHA1Sum":"caed8742ed3070f3d8d75c5d401b41d2ffb7aa32","SHA256Sum":"395804142dcfc9ca7c0101a7d61f307ab725d632ac6417a3eb655e1ed873963a","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d25ddccca094465af5c279763","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U30_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U30_3.66_04_01_2026.fwpkg","SHA1Sum":"2dfb7b004bdd591d079f45700bb09f57ee862a82","SHA256Sum":"aa899081c47d3fd8a67a840529969aee90afc68fc484a499f7c956b4119a00b5","SHA512Sum":"68c17afaca6bbc19857a773d1b2e5d94d8fa9f2479afc3b93262bf5aeb3228938674a2298e93ae0259304bbf839919c3aa3ea94e5735f99c4dc4fc2d0a477c98"}],"ComponentSizeInKB":32827,"CompsigList":[],"FileList":["payload.json","U30_3.66_04_01_2026.signed.flash","U30_3.66_04_01_2026.xml"],"Name":"U30_3.66_04_01_2026.fwpkg","SHA1Sum":"2dfb7b004bdd591d079f45700bb09f57ee862a82","SHA256Sum":"aa899081c47d3fd8a67a840529969aee90afc68fc484a499f7c956b4119a00b5","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7147abebc6b34ca3b1ddab6616","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.deb","SHA1Sum":"d68129c06981dbff7702e7006aa9ab89ffb2cb3e","SHA256Sum":"431ae7bb268bbd928c2d85763ae30f336aed84a0e2b1b8574441baed2b2eab7e","SHA512Sum":"b6cbcd713859a092ff9ed32d77d72dce8bf19fe96a278aad6cbe8826f9023e4f8fc4723149cd4125bf51b0a2ef74c9d5f872e39e9f04395eaf0949d0b75cca46"}],"ComponentSizeInKB":4727,"CompsigList":["firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/CP071739.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071739.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071739.scexe"],"Name":"firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.deb","SHA1Sum":"d68129c06981dbff7702e7006aa9ab89ffb2cb3e","SHA256Sum":"431ae7bb268bbd928c2d85763ae30f336aed84a0e2b1b8574441baed2b2eab7e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3686c100291e41f18ff4305bed","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-i40e-2.28.16-1.rhel10u1.x86_64.rpm","SHA1Sum":"a74f751d36fd67356f78292c6e906d1384666d77","SHA256Sum":"0a176f81b72eee5173449b790148616a93f70ca8710afbd58758841740d2ca72","SHA512Sum":"b90904db2bb4c2c7089172185d27eb0db47a79128336de834410d58680b845a75ff8cdf1fca0df0a59e9a93e63f2f9bdb31cf81ada195e1fca13b430c35fd5d9"}],"ComponentSizeInKB":539,"CompsigList":["kmod-i40e-2.28.16-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-i40e.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/i40e/i40e.ko","./usr/share/doc/kmod-i40e","./usr/share/doc/kmod-i40e/COPYING","./usr/share/doc/kmod-i40e/README","./usr/share/doc/kmod-i40e/pci.updates","./usr/share/man/man7/i40e.7.gz","./usr/share/smartupdate/kmod-i40e/component.xml"],"Name":"kmod-i40e-2.28.16-1.rhel10u1.x86_64.rpm","SHA1Sum":"a74f751d36fd67356f78292c6e906d1384666d77","SHA256Sum":"0a176f81b72eee5173449b790148616a93f70ca8710afbd58758841740d2ca72","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec805649d9"],"TypeOfChange":"1","Version":"2.28.16-1"},{"Checksum":[{"Filename":"kmod-i40e-2.28.16-1.rhel10u0.x86_64.rpm","SHA1Sum":"abb148ad31af728f6c8733693b8f8be8db792dc1","SHA256Sum":"293b44e0b16841b0e83054cec1aa7208bf79479f436d96f0d0b3e9c5ab5f6477","SHA512Sum":"7b810c34d9a8976fbc452ea6fb33f300307c45823fa086734a976007d6595e02e352ec177f57a72a5539e1fc7ed70c50872c5ad8293af67a95a88e24628d59e8"}],"ComponentSizeInKB":539,"CompsigList":["kmod-i40e-2.28.16-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-i40e.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/i40e/i40e.ko","./usr/share/doc/kmod-i40e","./usr/share/doc/kmod-i40e/COPYING","./usr/share/doc/kmod-i40e/README","./usr/share/doc/kmod-i40e/pci.updates","./usr/share/man/man7/i40e.7.gz","./usr/share/smartupdate/kmod-i40e/component.xml"],"Name":"kmod-i40e-2.28.16-1.rhel10u0.x86_64.rpm","SHA1Sum":"abb148ad31af728f6c8733693b8f8be8db792dc1","SHA256Sum":"293b44e0b16841b0e83054cec1aa7208bf79479f436d96f0d0b3e9c5ab5f6477","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec805649d9"],"TypeOfChange":"1","Version":"2.28.16-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90c89d8fb9d5456790e83dc73d","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069566.exe","SHA1Sum":"cdac6f896d70ceff4ebf7a247351a78c2bbbb644","SHA256Sum":"08e077a81acaef192ffd75e7b9a6d7d4f9aa39ac77c4103e0d0a54f6ad188e71","SHA512Sum":"aee99f6f73710f199c132198804bca6eb3879cf0cae93ca7b680978a630f991abb1f3a5b2b83bcca12a6429981383866adc0a4e5e9258fd10e7f5c8ac36a0ffe"}],"ComponentSizeInKB":3492,"CompsigList":["cp069566.compsig"],"FileList":["cp069566.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"Name":"cp069566.exe","SHA1Sum":"cdac6f896d70ceff4ebf7a247351a78c2bbbb644","SHA256Sum":"08e077a81acaef192ffd75e7b9a6d7d4f9aa39ac77c4103e0d0a54f6ad188e71","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9a4d9987d9a0415894252fe50a","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-8090159002bf","a6b1a447-382a-5a4f-1077-8090159002be","a6b1a447-382a-5a4f-1077-8090159002c0","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80901590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072361.zip","SHA1Sum":"946ca6afb19a6ee94101163ef4a59e58fa3a690e","SHA256Sum":"516123b27c25890f9da4095ef7c57b4eee05542c2c47d98ece8227b58e099ad2","SHA512Sum":"c70feab8ab4b49981eb9d13b6260081050e867edddf01a5a17e919482d1d8d0f989dc861673661023fb89b2f8288507e1d7f2c94c33978c2f1bec07eadc39170"}],"ComponentSizeInKB":26571,"CompsigList":["CP072361.compsig"],"FileList":["/CP072361.xml","/CP072361_VMw.zip","/payload.json","/CP072361.vmexe64","/CP072361.vmfile","/CP072361_VMw.zip/index.xml","/CP072361_VMw.zip/vendor-index.xml","/CP072361_VMw.zip/metadata.zip","/CP072361_VMw.zip/vib20/CP072361/HPE_bootbank_CP072361_1.0.0-8.0.0.21495797.vib","/CP072361_VMw.zip/metadata.zip/vendor-index.xml","/CP072361_VMw.zip/metadata.zip/vmware.xml","/CP072361_VMw.zip/metadata.zip/vibs/CP072361-2976989503376219690.xml","/CP072361_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072361_1.0.0-8.0.0.21495797.xml"],"Name":"CP072361.zip","SHA1Sum":"946ca6afb19a6ee94101163ef4a59e58fa3a690e","SHA256Sum":"516123b27c25890f9da4095ef7c57b4eee05542c2c47d98ece8227b58e099ad2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.8","VibList":[{"Name":"CP072361","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e9046babf2a48f69093440fd0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070971.zip","SHA1Sum":"5a1e1e8cd35e07ad2b53f7b49d604d1d7d136016","SHA256Sum":"b4ced99c90fd25350261c8e74470ec66f45b97e147e1469f6435e4c45c79646b","SHA512Sum":"70f83583dc59671697e150665d0b333fc7cafd80c1688860b73dba0454a473cc5cd35c0eb82ef62607b39b23565bee6c2682b244a96791424e0b4e88807981db"}],"ComponentSizeInKB":20192,"CompsigList":["CP070971.compsig"],"FileList":["/CP070971_BUILD_1.data","/CP070971.vmexe64","/CP070971.vmfile","/CP070971_VMw.zip","/CP070971.xml","/payload.json","/CP070971_VMw.zip/index.xml","/CP070971_VMw.zip/vendor-index.xml","/CP070971_VMw.zip/metadata.zip","/CP070971_VMw.zip/vib20/CP070971/HPE_bootbank_CP070971_HPD2.1-8.0.0.20613240.vib","/CP070971_VMw.zip/metadata.zip/vendor-index.xml","/CP070971_VMw.zip/metadata.zip/vmware.xml","/CP070971_VMw.zip/metadata.zip/vibs/CP070971-1673927667591334724.xml","/CP070971_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070971_HPD2.1-8.0.0.20613240.xml"],"Name":"CP070971.zip","SHA1Sum":"5a1e1e8cd35e07ad2b53f7b49d604d1d7d136016","SHA256Sum":"b4ced99c90fd25350261c8e74470ec66f45b97e147e1469f6435e4c45c79646b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070971","Version":"HPD2.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c32d0835396497484f16a5771","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-ixgbe-kmp-default-6.3.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"88c808fe3d2badf78ba613020b53ba5755ffe24f","SHA256Sum":"e1bc05477846dfc31c207f5e95413aecfa93a6711c16a0230d788c43d0334ca1","SHA512Sum":"4071d786be298b4f4c19dbd409168115ad4cfb8c149828ff31f785a21fc1f0e06878885877b624e730a21c6036421464c90c423db6a2d3077fe1eb195e69b738"}],"ComponentSizeInKB":375,"CompsigList":["hp-ixgbe-kmp-default-6.3.4_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"Name":"hp-ixgbe-kmp-default-6.3.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"88c808fe3d2badf78ba613020b53ba5755ffe24f","SHA256Sum":"e1bc05477846dfc31c207f5e95413aecfa93a6711c16a0230d788c43d0334ca1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.3.4-1"},{"Checksum":[{"Filename":"hp-ixgbe-kmp-default-6.3.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0b3e86e860d7bb8c84fb0b1903863f6132d93c3c","SHA256Sum":"9f2b2f9c16b75b3a7ab1163274c13e1794f8fe918fa59cebc9338772411622d0","SHA512Sum":"03d91017165b8fb350bff56fb363bad68aa3e3f9e6db81a95d7de4f0a0506d7c6eb0b518cfc57b2cbbad538294a27c93790954653faa0cb71360d7e327d7cb53"}],"ComponentSizeInKB":375,"CompsigList":["hp-ixgbe-kmp-default-6.3.4_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"Name":"hp-ixgbe-kmp-default-6.3.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0b3e86e860d7bb8c84fb0b1903863f6132d93c3c","SHA256Sum":"9f2b2f9c16b75b3a7ab1163274c13e1794f8fe918fa59cebc9338772411622d0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.3.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_55170dbd6ff54dc09aa6e53979","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_MR216i-a_Gen10P_52.36.3-6584_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.36.3-6584"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR216i-a_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"a56f085e9a43b172b11315e98ab7a6fcf4c43471","SHA256Sum":"2e3149634390ee3475d2fe3370cf181e0c99643a13d21f057fcd2bdb18d4d53f","SHA512Sum":"168755908ba4428240d28de61af6a15e260a059ad21b81ca1b35718be10fe8da568cac4262c32bef33cd35cbc5a751d6fe6e10554b76c9018b14eff587a8c190"}],"ComponentSizeInKB":7341,"CompsigList":[],"FileList":["HPE_MR216i-a_Gen10P_52.36.3-6584_A.HPb","HPE_MR216i-a_Gen10P_52.36.3-6584_A.xml","payload.json"],"Name":"HPE_MR216i-a_Gen10P_52.36.3-6584_A.fwpkg","SHA1Sum":"a56f085e9a43b172b11315e98ab7a6fcf4c43471","SHA256Sum":"2e3149634390ee3475d2fe3370cf181e0c99643a13d21f057fcd2bdb18d4d53f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.36.3-6584"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7b3ded01d6884e00885ead5742","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A47_4.04_04_02_2026.fwpkg","SHA1Sum":"a64a1b1a8d8ced5c606df19b4f7c02148bf8d39b","SHA256Sum":"39594a94d7311489639f02c68bb765003ac0862d12854f7450471bb5df295e90","SHA512Sum":"e60901fd46803e2c412e7a972fbe6f797b6c929c78eabd40901a2bfa4d42fa46ca6310de1f4f7dacdfaa45e8cc4444ed0cf5e1dea3ca8fd64a2a17325d41d4cf"}],"ComponentSizeInKB":32808,"CompsigList":[],"FileList":["A47_4.04_04_02_2026.signed.flash","A47_4.04_04_02_2026.xml","payload.json"],"Name":"A47_4.04_04_02_2026.fwpkg","SHA1Sum":"a64a1b1a8d8ced5c606df19b4f7c02148bf8d39b","SHA256Sum":"39594a94d7311489639f02c68bb765003ac0862d12854f7450471bb5df295e90","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9b0cf04bcc24d55b2f6124f56","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068666.exe","SHA1Sum":"d5add7de0b103d6b9f09017eb55b228239259c5f","SHA256Sum":"c48cad8ebb9094ae595c5a4a9139daa1923e2413bc9e73f4bfeb25c2679e2368","SHA512Sum":"ce0ad2b667ffacced251939c370dc2bfab3a30986827498b6dbdb1275ef886283c1b4a4cb3a7d20fe0d2e6e3d5a49060c5301480d129d1da34d90fb6b33690b5"}],"ComponentSizeInKB":4017,"CompsigList":["cp068666.compsig"],"FileList":["cp068666.xml","cpqsetup.exe","K401HPG5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068666.exe","SHA1Sum":"d5add7de0b103d6b9f09017eb55b228239259c5f","SHA256Sum":"c48cad8ebb9094ae595c5a4a9139daa1923e2413bc9e73f4bfeb25c2679e2368","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4949af45d6614c159f064c1c94","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068735.exe","SHA1Sum":"4e72ebdee545c54609248f4195c30bc5cc93ef1d","SHA256Sum":"6e05dbc080161ac07ca9ab5d5346f520be2bde3a47b8da9a2a9bbd516c93f92a","SHA512Sum":"0228ca1fbf3fc1dc1b877e3ddbef1d95044b6e458559ccf8257eb410e307bf680f8e955f3af8e81270d9be67412053b2badfa7a9fd4b6a8c86261a625e1c8e4f"}],"ComponentSizeInKB":4547,"CompsigList":["cp068735.compsig"],"FileList":["cp068735.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPESD5.rel","setup.dll"],"Name":"cp068735.exe","SHA1Sum":"4e72ebdee545c54609248f4195c30bc5cc93ef1d","SHA256Sum":"6e05dbc080161ac07ca9ab5d5346f520be2bde3a47b8da9a2a9bbd516c93f92a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3fd1113df84b4bf58e44e3280c","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Files":[{"Checksum":[{"Filename":"cp069565.exe","SHA1Sum":"697669b3a73bd04ca9eae8b5ca685be36cb9b126","SHA256Sum":"494bc5708fc74d78f2fac5a4c013b71d9005b5d856e3f3d1fe16fde9cda99db5","SHA512Sum":"ccd2fd1d56f44d49504e389d2fdef30ba270d967f232f40374ae30fa98861efccd5719d0a1d097c05be0f85f2f214064cb8e1db3ca13e522fa93010620a3f78c"}],"ComponentSizeInKB":4019,"CompsigList":["cp069565.compsig"],"FileList":["cp069565.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.19.27.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069565.exe","SHA1Sum":"697669b3a73bd04ca9eae8b5ca685be36cb9b126","SHA256Sum":"494bc5708fc74d78f2fac5a4c013b71d9005b5d856e3f3d1fe16fde9cda99db5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"5.3.9.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","SWKey":"evbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.13.165.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QlNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f97be98cdd384e279b5474536e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068642.exe","SHA1Sum":"f78287b419ce13242f6c7c1d3ffbdb3175f02d44","SHA256Sum":"399ddf887dba98f65b4cc790699fb38eed35be60bd01f34dab1064adb7a9684b","SHA512Sum":"b65133dc9c83c9de7892afca6d3b076c1e58f1b12252f42f18911d46cc41ad45de5508ecc442ae91c9eff465331f1d7ede6fc84bd90d353c88598f04776bc55e"}],"ComponentSizeInKB":4825,"CompsigList":["cp068642.compsig"],"FileList":["cp068642.xml","cpqsetup.exe","HPG1PM897.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068642.exe","SHA1Sum":"f78287b419ce13242f6c7c1d3ffbdb3175f02d44","SHA256Sum":"399ddf887dba98f65b4cc790699fb38eed35be60bd01f34dab1064adb7a9684b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8a0eab159b4b4e1bba5cf76f43","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"CP070835.zip","SHA1Sum":"98e5bf69e1b08d7c4cda82b4b3e19a17bd64f5b2","SHA256Sum":"5e74b31d66b7378b5eac0ca8d9d7993562c298b3685ca97ea0850586f068c038","SHA512Sum":"aa2c20b0bbc4e5a9d35b5dde803044795ce818d8801f95ba3ca65472c5c4ffbb4ca376d8de16f8913a18ade7ee2c1e170732f810244415e627c4225ad3b520ff"}],"ComponentSizeInKB":17975,"CompsigList":["CP070835.compsig"],"FileList":["/CP070835_BUILD_2.data","/CP070835.vmexe64","/CP070835.vmfile","/CP070835_VMw.zip","/CP070835.xml","/payload.json","/CP070835_VMw.zip/index.xml","/CP070835_VMw.zip/vendor-index.xml","/CP070835_VMw.zip/metadata.zip","/CP070835_VMw.zip/vib20/CP070835/HPE_bootbank_CP070835_HPG7.2-8.0.0.20613240.vib","/CP070835_VMw.zip/metadata.zip/vendor-index.xml","/CP070835_VMw.zip/metadata.zip/vmware.xml","/CP070835_VMw.zip/metadata.zip/vibs/CP070835-7004686765859091396.xml","/CP070835_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070835_HPG7.2-8.0.0.20613240.xml"],"Name":"CP070835.zip","SHA1Sum":"98e5bf69e1b08d7c4cda82b4b3e19a17bd64f5b2","SHA256Sum":"5e74b31d66b7378b5eac0ca8d9d7993562c298b3685ca97ea0850586f068c038","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7","VibList":[{"Name":"CP070835","Version":"HPG7.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e39f1ca7652a4f25ac5993e9b3","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.deb","SHA1Sum":"b0ad241639c29f337810e02d5df8d5dc5f9f5739","SHA256Sum":"162eeef3c39842823788bff7872c4ad89710ba39b6fbd8dc047604cb1f8efd0a","SHA512Sum":"6a4ca3cd3b7bb0f1e4babd06bf8b9d0fe19d4581ba5b7f5f8ed2b7ac85bb6faa9fd182bdae61d8f0a9b1214d6a58c2983d28b03f0074127d4d9d80895a7f533d"}],"ComponentSizeInKB":4665,"CompsigList":["firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/CP071776.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071776.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071776.scexe"],"Name":"firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.deb","SHA1Sum":"b0ad241639c29f337810e02d5df8d5dc5f9f5739","SHA256Sum":"162eeef3c39842823788bff7872c4ad89710ba39b6fbd8dc047604cb1f8efd0a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4ec7fc8ba9a6401d8dd66db3d7","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u1.x86_64.rpm","SHA1Sum":"873b25ef2a160566ed0da194282abd8fffb69974","SHA256Sum":"0680270a57e817c2832f6ef7433828232a0a90e73675d13c132d37c0a2aee1b5","SHA512Sum":"5e3c8d3b32b4b0b02686b8d895490e8914d6df7a93739e39a868b762ca4cdc624affe246e3cb91ccd7d9762dabecc38c14d35b69443643a15fa4a23b44e5aa9d"}],"ComponentSizeInKB":1390,"CompsigList":["kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u1.x86_64.rpm","SHA1Sum":"873b25ef2a160566ed0da194282abd8fffb69974","SHA256Sum":"0680270a57e817c2832f6ef7433828232a0a90e73675d13c132d37c0a2aee1b5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"},{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u0.x86_64.rpm","SHA1Sum":"3b2405672f96392bd673ed185e9ab4ce4924ff35","SHA256Sum":"7f06a826950dcc312fe4ccee34a8f861223fb8b591b4431423d614a1af3c0db4","SHA512Sum":"ab2831de294558d7d099412c4fee0b774c2700d685a7923570d51c3f40ddb0e7a4e675fdf7fa382a339477f3d8ace9bfa6ec2449acfd37ce416164b5d23bae77"}],"ComponentSizeInKB":1400,"CompsigList":["kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/drivers","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel10u0.x86_64.rpm","SHA1Sum":"3b2405672f96392bd673ed185e9ab4ce4924ff35","SHA256Sum":"7f06a826950dcc312fe4ccee34a8f861223fb8b591b4431423d614a1af3c0db4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_367aa667a8c3492798ca348579","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U47","U40","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U72","U70","U30","U26","U47","U50","HPE Apollo 2000 Gen10 Plus System","U64","03030201","U68","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp052054.zip","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","SHA512Sum":"ee3f0c24e44f2ac16e97846b0eec32503921fc4f0b9bbd7e604a01b821959d463063da490dfaa194899a33cca8898c73adc373716ea6f79e26b892f5000d4ee1"}],"ComponentSizeInKB":32,"CompsigList":["cp052054.compsig"],"FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp052054.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"Name":"cp052054.zip","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"InstallationDependency":{},"Name":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_710b214b710b478db82f6f2cc0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101315900221"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","I38","I41","I36","U34","U17","U34","P85","P89","U30","P89","U32","P89","U31","U20","U31","U20","U36","P86","U15","U15","U22","U41","P92","P99","U40","U21","U38","U38","I36","HPE Apollo 6500 Gen10 Plus (Chassis)","U19","U56","U61","U45","U25","U37","U24","U13","U12","U13","U14","U14","HPE Apollo sx40 Server","HPE Apollo pc40 Server","HPE Apollo kl20 Server","HPE Apollo am35 Server","I40","I43","I39","I40","I42","I37"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-82894b9e0a_0HPG1-2.1_amd64.deb","SHA1Sum":"a446b888b4cf944a43e93a8719e730f67a0603b2","SHA256Sum":"ef1990e4d37df2d7786aaabc0f7c39cf0c059250c5bca50e39006f81cdef234d","SHA512Sum":"51d276529154e6de83bab7be374c7e04211572c9a306eb44cbd1a82274e838a3846c37d78230ca8ae87874f4392baec24081772d47c6ff37c93eea85fbae807e"}],"ComponentSizeInKB":4534,"CompsigList":["firmware-hdd-82894b9e0a_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/CP071718.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071718.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071718.scexe"],"Name":"firmware-hdd-82894b9e0a_0HPG1-2.1_amd64.deb","SHA1Sum":"a446b888b4cf944a43e93a8719e730f67a0603b2","SHA256Sum":"ef1990e4d37df2d7786aaabc0f7c39cf0c059250c5bca50e39006f81cdef234d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_636f699fe81a47e3b6d02d945f","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069552.exe","SHA1Sum":"fafbd4ffb6ca9a8fa45b272464ff14deccae10ed","SHA256Sum":"6cadac092a76e7c6682cab3433a98577aa493690f2208143d93eb1884be7b837","SHA512Sum":"90066452fd6c3cc1f87c3a65253856e37a1edef940d6f628e2792fbf88cc6e750fbb78d22145235499a1a05afd2dbc5ab13536858bdcfdc8efb5608ba375003f"}],"ComponentSizeInKB":1016,"CompsigList":["cp069552.compsig"],"FileList":["cp069552.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069552.exe","SHA1Sum":"fafbd4ffb6ca9a8fa45b272464ff14deccae10ed","SHA256Sum":"6cadac092a76e7c6682cab3433a98577aa493690f2208143d93eb1884be7b837","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.2.7.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3116ddb609f54ed5ab42139bfa","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a42-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"8ba236f2998b55a8aa6d9b91e8dfab2e5057ce52","SHA256Sum":"016ba4e6dfff7ada5cfc1bd122b1e93b4faf6bac387d78b13d6e404a080d89a2","SHA512Sum":"8c81b0214015d56e9175588a29c7854d07ee7f3d0faf42131be6273dc28ec9ae6b0f2c2656e227ac44bd09a5e3607cc80f504c114391ddbbf8064abf3056c60b"}],"ComponentSizeInKB":33310,"CompsigList":["firmware-system-a42-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a42-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/A42_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/CP071520.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071520.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071520.scexe"],"Name":"firmware-system-a42-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"8ba236f2998b55a8aa6d9b91e8dfab2e5057ce52","SHA256Sum":"016ba4e6dfff7ada5cfc1bd122b1e93b4faf6bac387d78b13d6e404a080d89a2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a1272a0f2a74c92bc7882904f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070974.zip","SHA1Sum":"355f0fdcd64b48fd684cf5c0d2a1a8590669e71c","SHA256Sum":"39c7f30ffe64a656a2575341d9c6c3d5c98b21c0203c87170c30a218e64b1199","SHA512Sum":"e244a4cdcaa9701467a09b447780e316f4e063088342d7b90f725bd22543ef231f18fae74d58420c174cb09227f09dacd83498375beb209aa16469e025ae7e5f"}],"ComponentSizeInKB":19826,"CompsigList":["CP070974.compsig"],"FileList":["/CP070974_BUILD_1.data","/CP070974.vmexe64","/CP070974.vmfile","/CP070974_VMw.zip","/CP070974.xml","/payload.json","/CP070974_VMw.zip/index.xml","/CP070974_VMw.zip/vendor-index.xml","/CP070974_VMw.zip/metadata.zip","/CP070974_VMw.zip/vib20/CP070974/HPE_bootbank_CP070974_HPD6.1-8.0.0.20613240.vib","/CP070974_VMw.zip/metadata.zip/vendor-index.xml","/CP070974_VMw.zip/metadata.zip/vmware.xml","/CP070974_VMw.zip/metadata.zip/vibs/CP070974--1594029885113675755.xml","/CP070974_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070974_HPD6.1-8.0.0.20613240.xml"],"Name":"CP070974.zip","SHA1Sum":"355f0fdcd64b48fd684cf5c0d2a1a8590669e71c","SHA256Sum":"39c7f30ffe64a656a2575341d9c6c3d5c98b21c0203c87170c30a218e64b1199","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070974","Version":"HPD6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_409411b90dd3417d9971976ae9","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068940.zip","SHA1Sum":"65ced9a62f7fbb1b5c5535b0d448d8b5f9e884a7","SHA256Sum":"dac8fbb3846f7add1f74eefd8b823a625598bb4862e37a032b554f840d3f7a05","SHA512Sum":"64e6d2704c350ab96f7d916d53330ac6a6323d238ff63b43726053077503a16bdeec60b67e9f860d420919b88be1175c808774b88be14829512e47ae0211a14b"}],"ComponentSizeInKB":304,"CompsigList":["cp068940.compsig"],"FileList":["/cp068940.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/vib20/i40en/INT_bootbank_i40en_2.11.1.0-1OEM.800.1.0.20613240.vib","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/i40en--1194971387421857736.xml","/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-i40en_2.11.1.0-1OEM.800.1.0.20613240.xml"],"Name":"cp068940.zip","SHA1Sum":"65ced9a62f7fbb1b5c5535b0d448d8b5f9e884a7","SHA256Sum":"dac8fbb3846f7add1f74eefd8b823a625598bb4862e37a032b554f840d3f7a05","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"i40en","Version":"2.11.1.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.11.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.11.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e7138154c03743fcb5a6b72d23","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24384980ec_0HPD2-2.1_amd64.deb","SHA1Sum":"03bfc4e5dbe4020c7b4a0d3186368080a17ae95e","SHA256Sum":"4ef3e060943e7fa210310aa9ef699ec513dce83eed298f42fd4e9dcffb637b3f","SHA512Sum":"63308ca7f918f33712df42dcf0d4a8b3afa5a6da7cab3294f9dc6ec751ba1fce5c2ba5f462c9218ca733003f8eb1fe529584cf1835dea18c2bd9ae477809da10"}],"ComponentSizeInKB":3849,"CompsigList":["firmware-hdd-24384980ec_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/CP071747.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071747.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071747.scexe"],"Name":"firmware-hdd-24384980ec_0HPD2-2.1_amd64.deb","SHA1Sum":"03bfc4e5dbe4020c7b4a0d3186368080a17ae95e","SHA256Sum":"4ef3e060943e7fa210310aa9ef699ec513dce83eed298f42fd4e9dcffb637b3f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_368054cc44284a828b58c9a9cc","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_XXVDA2_SD_4p91_PLDMoMCTP_800214AB.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_4p91_PLDMoMCTP_800214AB.fwpkg","SHA1Sum":"4a5b90ae9a8c154797179844146fff193e11b85e","SHA256Sum":"d367a0304e6afacc1dc6dc41b4a65995f964cdb40049b8ab43a43369483f9b4b","SHA512Sum":"fc11b708ced78d3a87be28f8a3b6457c4cf69a5d590bd7c3053b5835b366577c6ead01f05e9247ea3399555fc41b03c39f18757bd80d4044ce203e48a7fbc42a"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_4p91_PLDMoMCTP_800214AB.HPb","HPE_E810_XXVDA2_SD_4p91_PLDMoMCTP_800214AB.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_4p91_PLDMoMCTP_800214AB.fwpkg","SHA1Sum":"4a5b90ae9a8c154797179844146fff193e11b85e","SHA256Sum":"d367a0304e6afacc1dc6dc41b4a65995f964cdb40049b8ab43a43369483f9b4b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47516fe2805f4e9ab3bc3e01fb","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860003"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","SHA1Sum":"4a3ccd3b466572bc8b5004fac711e56f22567fd5","SHA256Sum":"1ae2ea17b7661bb2d2409f06a4e2f2508f3c5dcd351a7ac0230aad2502d9efcc","SHA512Sum":"7a54d8e5dd70b82458ceb2b715011f527c6bacbb480ae866cef71ee60259037a0ad39c1b928ce7242c6a04260aadec6757dc6f8cabe4f7d6c8e631cd070491af"}],"ComponentSizeInKB":5261,"CompsigList":["firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/CP068776.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068776.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068776.scexe"],"Name":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","SHA1Sum":"4a3ccd3b466572bc8b5004fac711e56f22567fd5","SHA256Sum":"1ae2ea17b7661bb2d2409f06a4e2f2508f3c5dcd351a7ac0230aad2502d9efcc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c40a36ef0eb14c6ca2d92be35d","SupportedDevices":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-54addf5312_0HPK4-2.1_amd64.deb","SHA1Sum":"1e0357f5050fa633037224bfd16e540261acb717","SHA256Sum":"ea937c0a9565763661d8ac078577bf7d8f8d0cd21403ac98c80e275366ceda63","SHA512Sum":"55385d64f8eee1e0a0c318d85afdab3a6d191add198271f47ff6a4021ca630a94a6e92e7bd35dc683fff2e94a5097792a037978d64c2596071a35d71992e4cc5"}],"ComponentSizeInKB":3885,"CompsigList":["firmware-hdd-54addf5312_0HPK4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/CP071741.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071741.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071741.scexe"],"Name":"firmware-hdd-54addf5312_0HPK4-2.1_amd64.deb","SHA1Sum":"1e0357f5050fa633037224bfd16e540261acb717","SHA256Sum":"ea937c0a9565763661d8ac078577bf7d8f8d0cd21403ac98c80e275366ceda63","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c493c29c3814b949a0d96a017","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_Summit_SUMMITSUSSD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3432-3030-304a59455645","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Summit_SUMMITSUSSD3.fwpkg","SHA1Sum":"78ccea21d0e3d89d7de5138d3e62155cf39cb078","SHA256Sum":"b757e443c9fd1481c37b651d9e4a08ebfcd60ae7cf9f5de03ebdafa9c0863913","SHA512Sum":"3e37c790469677483d8344f7b1a7c95d4cd0d586975276b7637e114b492ba046314b2ab2e8a2bbdaa539918514b31ff26bd42db94b5a5671c0a50d68bbfcc58e"}],"ComponentSizeInKB":3679,"CompsigList":[],"FileList":["payload.json","Seagate_Summit_SUMMITSUSSD3.HPb","Seagate_Summit_SUMMITSUSSD3.xml"],"Name":"Seagate_Summit_SUMMITSUSSD3.fwpkg","SHA1Sum":"78ccea21d0e3d89d7de5138d3e62155cf39cb078","SHA256Sum":"b757e443c9fd1481c37b651d9e4a08ebfcd60ae7cf9f5de03ebdafa9c0863913","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3432-3030-304a59455645"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB24000JYEVE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB24000JYEVE","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54c9602889d54d00bfe7cae757","SupportedDevices":["002340a5-424d-3432-3030-304a59455645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-237.1.137.0-rhel9u7.x86_64.rpm","SHA1Sum":"ace46fb17f40c27b98e1acfc0ce26aa818d60408","SHA256Sum":"b7c730397293d40348e8e59b922e3b897985e28aff521e5572c19febecfe18cf","SHA512Sum":"e190dcbfcadabd664ab578f885d423678dfcd5b7ded16c51c33415706269bc776fb910d48a70f8ba3d2129eff13f37989d0dd176a5df402b1efee9456ab005ae"}],"ComponentSizeInKB":56,"CompsigList":["libbnxt_re-237.1.137.0-rhel9u7.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/ad5db936f1d2c6faa3227de617e7ef61d8917a","./usr/lib64/libbnxt_re-237.1.137.0.so","./usr/lib64/libbnxt_re-rdmav57.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-237.1.137.0-rhel9u7.x86_64.rpm","SHA1Sum":"ace46fb17f40c27b98e1acfc0ce26aa818d60408","SHA256Sum":"b7c730397293d40348e8e59b922e3b897985e28aff521e5572c19febecfe18cf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 7.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd5a74abe7b244288bebc1cba2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957412N4120HC.fwpkg","SHA1Sum":"b79c3bcf8a868759dfd98afb57719539f85ae75f","SHA256Sum":"a9d6e570f9e5da8e2e855f6d8417a88eccd24d5b0687b6201c736e270eee3501","SHA512Sum":"85cd999945596dac65114bd34ea83028884deba147320a123a17abfeb80572e3403beba6f7610885bdd93ba7350cf7a85d3ade597a56361a7970a7c8ec4f9215"}],"ComponentSizeInKB":1364,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957412N4120HC.HPb","BCM237.1.148.0_BCM957412N4120HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957412N4120HC.fwpkg","SHA1Sum":"b79c3bcf8a868759dfd98afb57719539f85ae75f","SHA256Sum":"a9d6e570f9e5da8e2e855f6d8417a88eccd24d5b0687b6201c736e270eee3501","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57412 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57412OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_91563f48b3ac44aba792ea8854","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069723.exe","SHA1Sum":"d31b6e8c5a5e394c51f9ea8c801fa31ffa426595","SHA256Sum":"2c18f6089adac226fd70ebb4b364fe9bd1a459b6b27f1719dd4cb4f623e27117","SHA512Sum":"854e44acad93cf838c25c0d664f1749e4d658af3c5adf4a1e3f1fee6bd262b04352b71c22bf67bcfdc0a2418989496a7acecb94ace6d86a0f9919e13d88c2dc8"}],"ComponentSizeInKB":583,"CompsigList":["cp069723.compsig"],"FileList":["cp069723.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp069723.exe","SHA1Sum":"d31b6e8c5a5e394c51f9ea8c801fa31ffa426595","SHA256Sum":"2c18f6089adac226fd70ebb4b364fe9bd1a459b6b27f1719dd4cb4f623e27117","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_62b2f5fb3af64069a682ab0c56","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U46","U46","U47","U47","U50","I44","H08","H08","H10","A48","U39","U40","U50","H10","H10","U60","U61","U56","A43","A43","A42","A42","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068749.exe","SHA1Sum":"fe5b3d34a007324d9151244e199202819467028f","SHA256Sum":"926d7a57e8af5a53ff1a3bcba9c2bcecf4bb1b57f787f77e715bb9d5de7a15cf","SHA512Sum":"6d9c4697968c5bd3406f68c6c83267cc6ee767ee8dd5839e992c7acf6eae564806bf77c689a017150e1839d56da6ff6cfbcc930011184d7cacce40e7d0f691d1"}],"ComponentSizeInKB":5212,"CompsigList":["cp068749.compsig"],"FileList":["cp068749.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2B3.rel","setup.dll"],"Name":"cp068749.exe","SHA1Sum":"fe5b3d34a007324d9151244e199202819467028f","SHA256Sum":"926d7a57e8af5a53ff1a3bcba9c2bcecf4bb1b57f787f77e715bb9d5de7a15cf","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c31b9cb8342244b7aab937df42","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"cp068646.exe","SHA1Sum":"c2d5c0dff623eca4cbc4b2692e2c856362d96661","SHA256Sum":"0de0c680e1af08b3a0a0e01165b231eec2f8302a54a0e24ba379c076ca1071d1","SHA512Sum":"579567c9177fb6685fa36d463c5222f2b22f1fcddaea7536f62fce1dfb63d06cdea50cab53cd8cb25c26c943f9a45a35311451c44b073b9a1adeff267745052b"}],"ComponentSizeInKB":4326,"CompsigList":["cp068646.compsig"],"FileList":["cp068646.xml","cpqsetup.exe","KACM6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068646.exe","SHA1Sum":"c2d5c0dff623eca4cbc4b2692e2c856362d96661","SHA256Sum":"0de0c680e1af08b3a0a0e01165b231eec2f8302a54a0e24ba379c076ca1071d1","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40522dcb139844feadb9548f07","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3231-3030-304759455350","Version":"HPG3"},{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3631-3030-304759455646","Version":"HPG3"},{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3032-3030-304759455648","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_SummitAN_SUMMITSUANG3.fwpkg","SHA1Sum":"0230c9da70b5ff84e8a16c69942fe770a21397d9","SHA256Sum":"f067a2e5d043c645c1a5f5c75e3253223a0b134f73700b8793b9cd349ea05a77","SHA512Sum":"81f948f4c806fce62bf05c03a8b4497dd3e177bbe00e01ceb599059177e1b7427c0baebd0e74f47a7b7e1f3ee55f3cdff3f01c57e376b1407c0c0cf9e43245b6"}],"ComponentSizeInKB":3681,"CompsigList":[],"FileList":["payload.json","Seagate_SummitAN_SUMMITSUANG3.HPb","Seagate_SummitAN_SUMMITSUANG3.xml"],"Name":"Seagate_SummitAN_SUMMITSUANG3.fwpkg","SHA1Sum":"0230c9da70b5ff84e8a16c69942fe770a21397d9","SHA256Sum":"f067a2e5d043c645c1a5f5c75e3253223a0b134f73700b8793b9cd349ea05a77","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB12000GYESP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB16000GYEVF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB20000GYEVH","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5f513eeaa56341f499c99db39a","SupportedDevices":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957416N4160HC.fwpkg","SHA1Sum":"82130445f7e945be54bed7618933fe49056e1fb8","SHA256Sum":"08ac7625a1258643c421031147194784e3f596051c604a7d53272ee746cb5c95","SHA512Sum":"693cc426c2bab413a6b8f4fec5c2e4ff81d430d5572ef3020da807659aa6de50ee593ee4701d245be7e7d7c154fcc645718c6fffed12cb019242bc9e19e5af19"}],"ComponentSizeInKB":1577,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957416N4160HC.HPb","BCM237.1.148.0_BCM957416N4160HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957416N4160HC.fwpkg","SHA1Sum":"82130445f7e945be54bed7618933fe49056e1fb8","SHA256Sum":"08ac7625a1258643c421031147194784e3f596051c604a7d53272ee746cb5c95","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57416 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57416OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_30a261e7ce0243fd860f55f93b","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp067949.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Files":[{"Checksum":[{"Filename":"cp069580.exe","SHA1Sum":"a86c698d10c506d7af5835b1b2d9f90e36aa605d","SHA256Sum":"ee0a13e771050c3209a72b24337e2a8d4710f55565c3a83c5848fdecf53f78fd","SHA512Sum":"006adf0a9bf36b26d4599f329d679690ea9bc0258bad28f659b2b97715ef156fd1e4c8e51622d514a1cf2bf9ca90e27a416a54246f020e80e7cddebf3261ebed"}],"ComponentSizeInKB":3704,"CompsigList":["cp069580.compsig"],"FileList":["cp067949.compsig","cp067949.zip","cp069580.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069580.exe","SHA1Sum":"a86c698d10c506d7af5835b1b2d9f90e36aa605d","SHA256Sum":"ee0a13e771050c3209a72b24337e2a8d4710f55565c3a83c5848fdecf53f78fd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c974efff3c5945fb8a83488562","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.65.21"}]},"Files":[{"Checksum":[{"Filename":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","SHA1Sum":"d0f2e1d909719bdd9e0e2cfc2530b400e1e986d5","SHA256Sum":"66892892a56f06f19cb227cf7d4711c1cf314f4803c738c7d1f2ca7e8b965546","SHA512Sum":"05250a53280fa557b2dfd8b4088cf9c38e7a31f5cc4cd34facf86c12622f3559e55f088f67d37d560c62bcca9a07233c915ca849d50438647755edf21f11b95b"}],"ComponentSizeInKB":1907,"CompsigList":[],"FileList":["payload.json","ql_ah_mbi_open_8.65.21_pldm.HPb","ql_ah_mbi_open_8.65.21_pldm.xml"],"Name":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","SHA1Sum":"d0f2e1d909719bdd9e0e2cfc2530b400e1e986d5","SHA256Sum":"66892892a56f06f19cb227cf7d4711c1cf314f4803c738c7d1f2ca7e8b965546","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-80f010770078"],"TypeOfChange":"1","Version":"8.65.21"}],"InstallationDependency":{},"MinimumActiveVersion":"8.55.12","Name":"Marvell FastLinQ Firmware Package for Arrowhead adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MARVELL_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b6ac273f485c467ca917614bc7","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","A47","A48","U46"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069543.exe","SHA1Sum":"e3e7158f66b761de3030515bda1e395d2eec726a","SHA256Sum":"aa058d4640fa160118c21c3decef95630c268cbc3195faddbbdbd91b78e38a49","SHA512Sum":"196070481eef7d115676dc2ed26a4eeb8ea10c73f8bbe19a70872a3bd8cce4ffb4d509a20af94e8371230ecd08ee985f10495ca490871eaef8082dc254c75d56"}],"ComponentSizeInKB":1057,"CompsigList":["cp069543.compsig"],"FileList":["cp069543.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069543.exe","SHA1Sum":"e3e7158f66b761de3030515bda1e395d2eec726a","SHA256Sum":"aa058d4640fa160118c21c3decef95630c268cbc3195faddbbdbd91b78e38a49","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a14deaf10d5470da0e2b4e08f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A43_4.04_04_02_2026.fwpkg","SHA1Sum":"304da07141e981ad5c1a5bd1f07eebe926225291","SHA256Sum":"27e85046a8daf7a3850153afc40045e5fb31e3f01cace1e78a6fc3beaa119f2a","SHA512Sum":"d215cf7e07e3b9dd54fc1e3eb1b61e50edd6f1e373d90077c3195c5c71dd52c3e2a66ec84c1403b1c9c4a9f4685222b0456317aafa28e53b66e2b2883df70d3f"}],"ComponentSizeInKB":32819,"CompsigList":[],"FileList":["A43_4.04_04_02_2026.signed.flash","A43_4.04_04_02_2026.xml","payload.json"],"Name":"A43_4.04_04_02_2026.fwpkg","SHA1Sum":"304da07141e981ad5c1a5bd1f07eebe926225291","SHA256Sum":"27e85046a8daf7a3850153afc40045e5fb31e3f01cace1e78a6fc3beaa119f2a","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f733631a13284947aacf491e0a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.rpm","SHA1Sum":"3b7024224ffa5bcb703da8701d22f536c34e6e10","SHA256Sum":"092d42c293d736651a196dbdb426cb622dec106c548ca72207b2bb75059274ce","SHA512Sum":"ad505c7dbc79d8edee24677dbaa9996095617bccc56e82c8ba0517ee88ee461a45ee34100d313b211dbc7574cfa950f62da55cffd2afca82697e6a7ce458ee6e"}],"ComponentSizeInKB":9534,"CompsigList":["firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/CP071762.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/HPE_luxor_8.23.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071762.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071762.scexe"],"Name":"firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.rpm","SHA1Sum":"3b7024224ffa5bcb703da8701d22f536c34e6e10","SHA256Sum":"092d42c293d736651a196dbdb426cb622dec106c548ca72207b2bb75059274ce","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7601bcbf4bb4614abc5029d86","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068757.exe","SHA1Sum":"c5556e20e4d511de3fed10f8293d1becb63e6d68","SHA256Sum":"db528426cdce592b369e2bc13677c63c7d9191c827eb28148babdc156b938f1f","SHA512Sum":"8f4c6a2685a9c4eebc2feebec6dbdc58621a83e2aac038fd0d69df8eaf2cf8d1061e4bfbad5b8424c83e4fe2d266ee1f7b021b474b58529a6b502f8e8f865bd5"}],"ComponentSizeInKB":3203,"CompsigList":["cp068757.compsig"],"FileList":["cp068757.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"Name":"cp068757.exe","SHA1Sum":"c5556e20e4d511de3fed10f8293d1becb63e6d68","SHA256Sum":"db528426cdce592b369e2bc13677c63c7d9191c827eb28148babdc156b938f1f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_76ebd18092bc4839b75f22e866","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","SHA1Sum":"e461016954ad2eb9545afbaa7c8add4da6303776","SHA256Sum":"5c7c8916c5e01acc8d310197b0246382b6ed8699755247d01f2fbf79b65c6f9a","SHA512Sum":"17a2c0da8c83835bf6ddf5635e5cdf445143cdad61149e92dfc521e5f65317c71c888617759341b34802ba824044eabc65677aa0aa27091f018d84226e8bc06e"}],"ComponentSizeInKB":847,"CompsigList":["HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.compsig"],"FileList":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-aarch64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","SHA1Sum":"e461016954ad2eb9545afbaa7c8add4da6303776","SHA256Sum":"5c7c8916c5e01acc8d310197b0246382b6ed8699755247d01f2fbf79b65c6f9a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"TypeOfChange":"1","Version":"6.0.0.1-4"}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_10f65b3327384eed803da4c0f1","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"firmware-fc-emulex-2026.06.01-1.4.x86_64.rpm","SHA1Sum":"f0e8ddf28119f2897c9eea2f987d14c1c542061c","SHA256Sum":"82c34f2b65d2512c266323a1c9accd4eec87951e4c4e39c07bc4d3c987784385","SHA512Sum":"0a908188de4a9ba8bf4fda79c5e593c383045425a2e2d2dabbbe9fb019de54c5c39f6677d81824269f6fe92c87ce900e3feff8ea5bfa2387318caa7dbfa8a28a"}],"ComponentSizeInKB":13947,"CompsigList":["firmware-fc-emulex-2026.06.01-1.4.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/CP071319.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/elxflashStandalone-linux-14.4.731.21-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware/B14473121.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware/P14473121.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071319.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071319.scexe"],"Name":"firmware-fc-emulex-2026.06.01-1.4.x86_64.rpm","SHA1Sum":"f0e8ddf28119f2897c9eea2f987d14c1c542061c","SHA256Sum":"82c34f2b65d2512c266323a1c9accd4eec87951e4c4e39c07bc4d3c987784385","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac5358a08e71413698d2d477d2","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071327.exe","SHA1Sum":"88a790844e265561a3fb65fa015037c6a08550cc","SHA256Sum":"7a2410796254246b0bbf2be6acf881c41dfe7912594fef940158176ccb607e15","SHA512Sum":"9896e34fee9ee431f5985bd0b6690fae71c84f315b0f884d5d8a72991203524016137583a7940dfc5a7feb26fdc645323326ef29d601ab1135a4ecf663c9a4b4"}],"ComponentSizeInKB":1100,"CompsigList":["cp071327.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp071327.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071327.exe","SHA1Sum":"88a790844e265561a3fb65fa015037c6a08550cc","SHA256Sum":"7a2410796254246b0bbf2be6acf881c41dfe7912594fef940158176ccb607e15","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"237.1.124.0"}],"InstallationDependency":{},"Name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7bd8903c7144b80aa5360fe76","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-181914e41760","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14E4-180800000000","a6b1a447-382a-5a4f-14E4-181B00000000","a6b1a447-382a-5a4f-14E4-180900000000","a6b1a447-382a-5a4f-14E4-181B00000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","H10","H10","H10","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","SHA1Sum":"89067d369f8d26e3ed35b0fcae06c335633e21d1","SHA256Sum":"961034c61d8c6ac996e37e634db202b240665ee625e6e390360a6364ef923a81","SHA512Sum":"1654eed99f66dcfe3a01ef808a70fab3fb6bfce5811b669392df70302e295dd69cf29f75a7384f0fc51df22068b11413001e766e4815a9888adc95353089b8c6"}],"ComponentSizeInKB":6142,"CompsigList":["firmware-hdd-3815d4b024-GPK8-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/CP068921.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068921.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068921.scexe"],"Name":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","SHA1Sum":"89067d369f8d26e3ed35b0fcae06c335633e21d1","SHA256Sum":"961034c61d8c6ac996e37e634db202b240665ee625e6e390360a6364ef923a81","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e10cdbf81fd44dc998fb58d4e8","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-237.1.137.0.sles16sp0.x86_64.rpm","SHA1Sum":"1830e0a265087fe9618911aac3252a22c4f8db2d","SHA256Sum":"350b0c835b518b8bd6e61e7a8f533a275e9cf99968e624a9b28b91c619bdd9c1","SHA512Sum":"629968cefd7a32e12d12b6247208a2709fabea93757628e00c4371d48e332c80eb787e453300caf5ec795018077b3bef952f40dccdc4cc614a70f685cc80dab3"}],"ComponentSizeInKB":1351,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-237.1.137.0.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/bnxt_en.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-237.1.137.0.sles16sp0.x86_64.rpm","SHA1Sum":"1830e0a265087fe9618911aac3252a22c4f8db2d","SHA256Sum":"350b0c835b518b8bd6e61e7a8f533a275e9cf99968e624a9b28b91c619bdd9c1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46efa27a1f1b4e079c9f64261c","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-3047584e5842","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3047584e5a4b","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3053584e5843","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3047584e5a4c","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3053584e5a50","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-3047584e5a4e","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-3047584e5755","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3047584e5a41","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3053584e5756","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-3047584e5a42","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3047584e5a43","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3053584e5a46","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-3047584e5a44","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-3047584e5a45","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3234-3047584e5841","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3438-3047584e5a48","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"Micron_5400_M5400ALLHPG1.fwpkg","SHA1Sum":"27aee03c83eca71eef5cec16d5fa21b6125d949c","SHA256Sum":"8983bfd85cf5d061b13ae383f81c8907a90f1a737b7910ff88e0f255ba4cbb4c","SHA512Sum":"0894d1d5cea5a027b2ef3571b34831842b261eb9f288f28e314aff4760df709ba7528d074df4016a22817a7ae71551cbaf86454fdf0534d97c476431bf528ed1"}],"ComponentSizeInKB":4812,"CompsigList":[],"FileList":["Micron_5400_M5400ALLHPG1.HPb","Micron_5400_M5400ALLHPG1.xml","payload.json"],"Name":"Micron_5400_M5400ALLHPG1.fwpkg","SHA1Sum":"27aee03c83eca71eef5cec16d5fa21b6125d949c","SHA256Sum":"8983bfd85cf5d061b13ae383f81c8907a90f1a737b7910ff88e0f255ba4cbb4c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-3047584e5842","4d2340a5-304b-3030-3936-3047584e5a4b","4d2340a5-304b-3030-3936-3053584e5843","4d2340a5-304b-3130-3932-3047584e5a4c","4d2340a5-304b-3130-3932-3053584e5a50","4d2340a5-304b-3330-3834-3047584e5a4e","562340a5-304b-3030-3234-3047584e5755","562340a5-304b-3030-3438-3047584e5a41","562340a5-304b-3030-3438-3053584e5756","562340a5-304b-3030-3936-3047584e5a42","562340a5-304b-3130-3932-3047584e5a43","562340a5-304b-3130-3932-3053584e5a46","562340a5-304b-3330-3834-3047584e5a44","562340a5-304b-3730-3638-3047584e5a45","562340a5-3052-3030-3234-3047584e5841","562340a5-3052-3030-3438-3047584e5a48"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Universal Firmware Package for Drives - MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC and MK001920SXNZP","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GXNXB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GXNZK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GXNZL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GXNZN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GXNWU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GXNZA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GXNZB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GXNZC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GXNZD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GXNZE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480SXNWV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920SXNZF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960SXNXC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920SXNZP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000240GXNXA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000480GXNZH","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_02859ac29430461593ee92cdbd","SupportedDevices":["4d2340a5-304b-3030-3438-3047584e5842","4d2340a5-304b-3030-3936-3047584e5a4b","4d2340a5-304b-3130-3932-3047584e5a4c","4d2340a5-304b-3330-3834-3047584e5a4e","562340a5-304b-3030-3234-3047584e5755","562340a5-304b-3030-3438-3047584e5a41","562340a5-304b-3030-3936-3047584e5a42","562340a5-304b-3130-3932-3047584e5a43","562340a5-304b-3330-3834-3047584e5a44","4d2340a5-304b-3030-3936-3053584e5843","4d2340a5-304b-3130-3932-3053584e5a50","562340a5-304b-3130-3932-3053584e5a46","562340a5-304b-3030-3438-3053584e5756","562340a5-304b-3730-3638-3047584e5a45","562340a5-3052-3030-3234-3047584e5841","562340a5-3052-3030-3438-3047584e5a48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b460823f70-HPG4-1.1.x86_64.rpm","SHA1Sum":"cc7dfe4a1d255a10967f6872c307fc8451bece6d","SHA256Sum":"83cefbc197cc712352f311db7850d4a8c1aa60493ffaa05fba6bfc12163d3468","SHA512Sum":"675d4c570ee17ad1aac7cdb63b36f368bc41358327e14a4ad577dbf087c1427c0c2ceedd39950d95afef062f500a2ad1a952111921c57af6b51647b8618ae4f5"}],"ComponentSizeInKB":5152,"CompsigList":["firmware-hdd-b460823f70-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/CP072162.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/M52008TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072162.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072162.scexe"],"Name":"firmware-hdd-b460823f70-HPG4-1.1.x86_64.rpm","SHA1Sum":"cc7dfe4a1d255a10967f6872c307fc8451bece6d","SHA256Sum":"83cefbc197cc712352f311db7850d4a8c1aa60493ffaa05fba6bfc12163d3468","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f5f5e93d0ec4625934183860d","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"cp072094.exe","SHA1Sum":"003de43c383523a813cca136277699e78fb430b0","SHA256Sum":"3103210bae68e2efa1febb1341d7cbde8b4a4f5c8c4cd4622127a3e18a19ecc3","SHA512Sum":"bd90798e377b3549b6ced2aaa75bedd164d65d59b74a36a2d556429584ec6f50509614fc7510f14807b790127d6d2776c4c2b85b51ec5498489b6da77226e618"}],"ComponentSizeInKB":905,"CompsigList":["cp072094.compsig"],"FileList":["ACCE_2.1.0s.bin","cp072094.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072094.exe","SHA1Sum":"003de43c383523a813cca136277699e78fb430b0","SHA256Sum":"3103210bae68e2efa1febb1341d7cbde8b4a4f5c8c4cd4622127a3e18a19ecc3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 -  HPE Edgeline Chassis Controller Firmware","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b4e3a5d725374940aea4439eb7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","FTP","H11","H08","H10","H11"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U50_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071456.exe","SHA1Sum":"f0dec5dd2a320224afb8810fe0d7bf7d60a460d0","SHA256Sum":"d72d3a2be3810e1a3e46165f1e04202f62931ef34fd5aeebfea4479fb44d67bc","SHA512Sum":"82af97a6abd11245ce4c9e9d9f2f0e1131177d6fcc144a56c6270a351313ae4655b251f61bc43c8c7d048c34380cfc595e16936b3788fec6ff4624af2561d237"}],"ComponentSizeInKB":33439,"CompsigList":["cp071456_part1.compsig","cp071456_part2.compsig"],"FileList":["cp071456.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U50_2.64_04_01_2026.signed.flash"],"Name":"cp071456.exe","SHA1Sum":"f0dec5dd2a320224afb8810fe0d7bf7d60a460d0","SHA256Sum":"d72d3a2be3810e1a3e46165f1e04202f62931ef34fd5aeebfea4479fb44d67bc","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c9c2bdebe61488bb219233fe4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.deb","SHA1Sum":"d1cab569ca6d68dc6e6fc8b69c25550417b05a26","SHA256Sum":"503c3adee4b322819a8501912c43575677fb5608e453cf6e2b67e63c16777ab6","SHA512Sum":"0b5d6d226cffed111fe2d3ce03a5267b909efc09f5bea65835224bc5c600d8a0c0d051c722bbac4d2ec4415ad966510579471d18c41f6a759391126db37ac2d4"}],"ComponentSizeInKB":3255,"CompsigList":["firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/CP071700.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071700.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071700.scexe"],"Name":"firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.deb","SHA1Sum":"d1cab569ca6d68dc6e6fc8b69c25550417b05a26","SHA256Sum":"503c3adee4b322819a8501912c43575677fb5608e453cf6e2b67e63c16777ab6","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu – HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_85e49e85ca434469899db308f7","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"cp068640.exe","SHA1Sum":"7a41ae94dcbc0083ecfdedd576b5b8c3e7129685","SHA256Sum":"b71425c25e9587f3cd160c3bc13b98972359749dd0884599232d726f9d2710c0","SHA512Sum":"f8d2c65eb5b568b9701e354ed9fbad30feae20ade5d3b5e3e03619ef628ccc22f0aad24c199c58cdee061a3bd28fc0ebb6926b2e3dc681e6caeab0aff9c17c03"}],"ComponentSizeInKB":7820,"CompsigList":["cp068640.compsig"],"FileList":["cp068640.xml","cpqsetup.exe","mnv_cli.exe","MPK7825Q.rel","payload.json","setup.dll"],"Name":"cp068640.exe","SHA1Sum":"7a41ae94dcbc0083ecfdedd576b5b8c3e7129685","SHA256Sum":"b71425c25e9587f3cd160c3bc13b98972359749dd0884599232d726f9d2710c0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-0 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_058d8510e4c84af39df1c07ce8","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ice-kmp-default-2.4.5_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"e083079601743a7dbd451f5e2c76db3d935cbf99","SHA256Sum":"7bd28437eb7a98d40a48db2288bc8737aa6d394f989b63f29b5ba05231d8b7b7","SHA512Sum":"703a46fa4898b3bdfd435345bf74e4245ea207835dc8ad3b08359e86cb2026a9364fe82a3058a5cbc5e5cecf577bda01bec7654c5dbd4e796fdb54d8cda5f119"}],"ComponentSizeInKB":1031,"CompsigList":["ice-kmp-default-2.4.5_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/ice.ko","./usr/share/doc/packages/ice-kmp-default","./usr/share/doc/packages/ice-kmp-default/COPYING","./usr/share/doc/packages/ice-kmp-default/README","./usr/share/man/man7/ice.7.gz","./usr/share/pci.ids.d/pci.ids.ice-kmp-2.4.5","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.4.5_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"e083079601743a7dbd451f5e2c76db3d935cbf99","SHA256Sum":"7bd28437eb7a98d40a48db2288bc8737aa6d394f989b63f29b5ba05231d8b7b7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.4.5-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd68b07ce04946a7b2a566680d","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070963.zip","SHA1Sum":"c6c04a55208609bfb337a7fa4efc895ca4371821","SHA256Sum":"b2a458d0a3d871c816658ca00d3c960bc43feccadcb0c245acf9366f79c33115","SHA512Sum":"8a3f737edf38f7b82c65459dc6d43dd9a36daa9de2b17b4a5cadbaabd16e2297ce69f815b151654a4525fd62749bda4196d6d5df5fb3c4e695aabae13665ca52"}],"ComponentSizeInKB":21737,"CompsigList":["CP070963.compsig"],"FileList":["/CP070963_BUILD_1.data","/CP070963.vmexe64","/CP070963.vmfile","/CP070963_VMw.zip","/CP070963.xml","/payload.json","/CP070963_VMw.zip/index.xml","/CP070963_VMw.zip/vendor-index.xml","/CP070963_VMw.zip/metadata.zip","/CP070963_VMw.zip/vib20/CP070963/HPE_bootbank_CP070963_HPD3.1-8.0.0.20613240.vib","/CP070963_VMw.zip/metadata.zip/vendor-index.xml","/CP070963_VMw.zip/metadata.zip/vmware.xml","/CP070963_VMw.zip/metadata.zip/vibs/CP070963-4749097202626109637.xml","/CP070963_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070963_HPD3.1-8.0.0.20613240.xml"],"Name":"CP070963.zip","SHA1Sum":"c6c04a55208609bfb337a7fa4efc895ca4371821","SHA256Sum":"b2a458d0a3d871c816658ca00d3c960bc43feccadcb0c245acf9366f79c33115","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070963","Version":"HPD3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f64e39d61624d1ab3a445de00","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3496cc4743_0HPG3-2.1_amd64.deb","SHA1Sum":"cb4e3f98dcdf4665e2e196303144caa44710b599","SHA256Sum":"33fe1c148d78cfdffee1d2bdc4de4736ad4c3cfdbde0c56bdbfc68404b0e3a3e","SHA512Sum":"3b57325be2356e467ab6cba9791d26cfcf83ceccb583d476ad39973ae017759c4680465c75f9fd58adccb44ce9509539f762c08dcd3045fc7e002fc10ea2d806"}],"ComponentSizeInKB":4230,"CompsigList":["firmware-hdd-3496cc4743_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/CP071770.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071770.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071770.scexe"],"Name":"firmware-hdd-3496cc4743_0HPG3-2.1_amd64.deb","SHA1Sum":"cb4e3f98dcdf4665e2e196303144caa44710b599","SHA256Sum":"33fe1c148d78cfdffee1d2bdc4de4736ad4c3cfdbde0c56bdbfc68404b0e3a3e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc927d993d3e41a2ae84949c49","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U40_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071410.exe","SHA1Sum":"e574b7179d29d51abfd0733c11be1b95b097abe4","SHA256Sum":"f426f3d33b50cac4f20ac60da299b5f92cbdf9d47104a3f0fa490830bca9a2d4","SHA512Sum":"620a12cbabd05101c8e3c23b1ac7afd9cd8b86fab7cd8cbea10c86daaba7eb880fd1bd6ac67ec27651031f3e31f6fe73a36880e1a45bb84ba6790dff600812df"}],"ComponentSizeInKB":11550,"CompsigList":["cp071410.compsig"],"FileList":["cp071410.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_3.66_04_01_2026.signed.flash"],"Name":"cp071410.exe","SHA1Sum":"e574b7179d29d51abfd0733c11be1b95b097abe4","SHA256Sum":"f426f3d33b50cac4f20ac60da299b5f92cbdf9d47104a3f0fa490830bca9a2d4","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fcd55d98111243c698ecddcafe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070548.exe","SHA1Sum":"5534efa19186ce76e5050063d615b5f4b0e90128","SHA256Sum":"349825bb28717a0d15a9c119a2d46798860314b95c12b3485056366919adf428","SHA512Sum":"a128eac9adc604cb3eb7a3b1b5f43c6ceebdd45e08a9c52bceedb412b14d34d9522883cfd21c407692f2e85d53469f4bef02c36d151608c9ace0a9ffb646bc64"}],"ComponentSizeInKB":1511,"CompsigList":["cp070548.compsig"],"FileList":["cp070548.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070548.exe","SHA1Sum":"5534efa19186ce76e5050063d615b5f4b0e90128","SHA256Sum":"349825bb28717a0d15a9c119a2d46798860314b95c12b3485056366919adf428","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.24.41.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a901811c6f974af88394485a10","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","SHA1Sum":"36c9a3829f935c8161f3e1c0652d6dd08489765b","SHA256Sum":"c6bbc1f54ca33e16d38495cfacd8f9fcbb7ae4305aaa1298f8e83bb8e6373034","SHA512Sum":"3d5e0f91051b8022a1b4c73c344a3e236244dbfcbbeeccde24f55639da3f913b4b5b14be08f381aefd4ed12d2ab976c771be9b6f65814f7f678d8b34c5f4b3e1"}],"ComponentSizeInKB":6620,"CompsigList":["firmware-hdd-9475583fb5-HPG1-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/CP068917.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/HPG1_PM897.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068917.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068917.scexe"],"Name":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","SHA1Sum":"36c9a3829f935c8161f3e1c0652d6dd08489765b","SHA256Sum":"c6bbc1f54ca33e16d38495cfacd8f9fcbb7ae4305aaa1298f8e83bb8e6373034","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_09fad2ae6ae840ae99f4ef3701","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"cp070007.exe","SHA1Sum":"a882130d529949f6a07a90aecdde811cdc9aa1a8","SHA256Sum":"2a4c9fbb7203423a6e082f4380dc0e19ca1688347fdfcb06f58d9ae618795068","SHA512Sum":"f75fdf418ec5fe6be8b45c54c1d06950c2d26824425cac063fb7b6b9c96c28858346e597cce43db0d1e8365e5f0d74b430fd1ecad545eaa143837477b6ff2b10"}],"ComponentSizeInKB":5027,"CompsigList":["cp070007.compsig"],"FileList":["Config.xml","cp070007.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"Name":"cp070007.exe","SHA1Sum":"a882130d529949f6a07a90aecdde811cdc9aa1a8","SHA256Sum":"2a4c9fbb7203423a6e082f4380dc0e19ca1688347fdfcb06f58d9ae618795068","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c2e096616fa40d5a40729ac02","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u6.x86_64.rpm","SHA1Sum":"334fc8843f8965b74c0c9133ce09cc3f79d9e261","SHA256Sum":"e9515ca052a98cf56fc9a481562a0d0688d837f6078b960851b693670925a75a","SHA512Sum":"968232e55c51bfd2c86feac6f5abda62654c66249f0b448a9a2342cf001c81f37c5e0319d5a90fa4b80a0ba442ce1b189f6bad35d7453b0f9e5041f29f408d48"}],"ComponentSizeInKB":1350,"CompsigList":["kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u6.x86_64.rpm","SHA1Sum":"334fc8843f8965b74c0c9133ce09cc3f79d9e261","SHA256Sum":"e9515ca052a98cf56fc9a481562a0d0688d837f6078b960851b693670925a75a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"},{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u7.x86_64.rpm","SHA1Sum":"e59952f42718df36eb8fbc887af488828cd630ff","SHA256Sum":"aa0da636cdc573bbb22ff4b934e95feb9a26cf893f9fa662bfcff8e30ec20c8b","SHA512Sum":"5ab10b99c5a5a372947ca15f6ab914ba8e87828e6c8b0bafd6df135d8f4942a792dbda104e3d5b9c042e22ea0da06abcfd52a05e26d1983db83e4e5b314f946e"}],"ComponentSizeInKB":1375,"CompsigList":["kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-237.1.137.0.rhel9u7.x86_64.rpm","SHA1Sum":"e59952f42718df36eb8fbc887af488828cd630ff","SHA256Sum":"aa0da636cdc573bbb22ff4b934e95feb9a26cf893f9fa662bfcff8e30ec20c8b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42302a9b7f4a4594ba73755200","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U47","U40","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","A59","U72","U70","U30","U26","U47","U50","HPE Apollo 2000 Gen10 Plus System","U64","03030201","U68","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-igb-kmp-default-6.19.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"039886d188928662b0db5690d155c3590ccab975","SHA256Sum":"2a02c9d738e31e506693f835781dbaf7c8487fc87a9a81fb5bbb3b1cdaa76f6c","SHA512Sum":"5eb98e783b2ccc5d66913cf724805f80148fcae8007c1170ed62f8cfed8b934349e58484717286387ad0e61c247d1c26d78aa1cd126d3b98d6f12d2948ccb357"}],"ComponentSizeInKB":176,"CompsigList":["hp-igb-kmp-default-6.19.10_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-igb","./lib/modules/6.4.0-150600.21-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"Name":"hp-igb-kmp-default-6.19.10_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"039886d188928662b0db5690d155c3590ccab975","SHA256Sum":"2a02c9d738e31e506693f835781dbaf7c8487fc87a9a81fb5bbb3b1cdaa76f6c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.19.10-1"},{"Checksum":[{"Filename":"hp-igb-kmp-default-6.19.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"e017f8e59d662732246395fa9193cc1f24321860","SHA256Sum":"dfb5d74086049a614725dd5a32e2cb7a943855f1ccb70e69affe118f7d4c916f","SHA512Sum":"85be84a3238f3463b253ce7e3a0a03c7acaf229d72846aee78a7b67682fbe0edea5f523b2d04eeb15e8ec464a13246a6312a0d87df28f7f694c3807e28b8d46a"}],"ComponentSizeInKB":175,"CompsigList":["hp-igb-kmp-default-6.19.10_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-igb","./lib/modules/6.4.0-150700.51-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"Name":"hp-igb-kmp-default-6.19.10_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"e017f8e59d662732246395fa9193cc1f24321860","SHA256Sum":"dfb5d74086049a614725dd5a32e2cb7a943855f1ccb70e69affe118f7d4c916f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.19.10-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_991082d63ec04d0bac0e9ca762","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ca21e169e2_0HPG1-2.1_amd64.deb","SHA1Sum":"f68467ec36f6759a346aab5d6af1e71d9ed3d2e7","SHA256Sum":"9d2551fd81f5e79496f524eafc04c3261ffd75ea3290779ce78602a51341f0a0","SHA512Sum":"e0332579c0b658a9c98f0862d6721598d29f1fe8f77a6bb384815ffedfa77e9ee033c923e0ab9de167580020b857731e85d6402d8af31965803e77a08d44c673"}],"ComponentSizeInKB":4629,"CompsigList":["firmware-hdd-ca21e169e2_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/CP071777.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071777.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071777.scexe"],"Name":"firmware-hdd-ca21e169e2_0HPG1-2.1_amd64.deb","SHA1Sum":"f68467ec36f6759a346aab5d6af1e71d9ed3d2e7","SHA256Sum":"9d2551fd81f5e79496f524eafc04c3261ffd75ea3290779ce78602a51341f0a0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_943fad23039845608a74678ddb","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U56_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U56_2.64_04_01_2026.fwpkg","SHA1Sum":"faa1169885c1323d3b57fcecfb5dc9b20cd8e16b","SHA256Sum":"43576c80915f4526c6a5e2e437a7870333d4868b25c7e8b6c5a5a40835c57041","SHA512Sum":"955a4cdd230bbed71a5288af699f78fdb49c33b89d9587783d7025c9a0829feb844a27fee13050b6878c958d47a6f24f20d675768236c5e962c04ae746fb9775"}],"ComponentSizeInKB":32815,"CompsigList":[],"FileList":["payload.json","U56_2.64_04_01_2026.signed.flash","U56_2.64_04_01_2026.xml"],"Name":"U56_2.64_04_01_2026.fwpkg","SHA1Sum":"faa1169885c1323d3b57fcecfb5dc9b20cd8e16b","SHA256Sum":"43576c80915f4526c6a5e2e437a7870333d4868b25c7e8b6c5a5a40835c57041","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_623775af4b814dd5b8d98f2609","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U56","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mft-4.36.0-147.sles16sp0.x86_64.rpm","SHA1Sum":"0a220ef5bd7ab474d9f6f9ccbd2d9a28eb30e077","SHA256Sum":"eaaf676cd5cf61e1535fa43818c620283af500a8b097cd56334379f40bf3b93e","SHA512Sum":"bbb5a78e59cfee58303c044f64eea193933ed85cdb814e86b2b45a3673fb88d75c71ebe391dde7cba8212e24a60287f843c0e1e97c2828ae9003d5768f95e287"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles16sp0.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles16sp0.x86_64.rpm","SHA1Sum":"0a220ef5bd7ab474d9f6f9ccbd2d9a28eb30e077","SHA256Sum":"eaaf676cd5cf61e1535fa43818c620283af500a8b097cd56334379f40bf3b93e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.rpm","SHA1Sum":"a301c6f78bbe8a4e7859b1498cf2b84aef527131","SHA256Sum":"0a8954be6aced62605ad64e1e542a69310208a2a63fe6cf57e3f060d787c299c","SHA512Sum":"1e962f8f90c63098987efa55d31f5ddf5c85808218cf32938b7229bac454fb057e402190744a6210b8de7d830847551c075d63fea30ae19d596750708af6cc79"}],"ComponentSizeInKB":83,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/mst_pci.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.rpm","SHA1Sum":"a301c6f78bbe8a4e7859b1498cf2b84aef527131","SHA256Sum":"0a8954be6aced62605ad64e1e542a69310208a2a63fe6cf57e3f060d787c299c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 16 SP0 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f399b0cc48634f37902d482c36","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"CP071318.zip","SHA1Sum":"ac3a4b10b8b5f2480c72108bc04e8ffa0d69a95a","SHA256Sum":"98d7ec40e3dbb929dcdf3ab002a4a67d27453c1fb16ac8f65cd0fccad8c97479","SHA512Sum":"40f020683658836254215922d65b2ce5250130630619dad6cc8533e84a6f90cc2be87c4b6a2ca4bdde1ad58206701e54222eff72633f705e25556f49b101fde1"}],"ComponentSizeInKB":4727,"CompsigList":["CP071318.compsig"],"FileList":["/CP071318_BUILD_4.data","/CP071318.vmexe","/CP071318.vmexe64","/CP071318.vmfile","/CP071318_VMw.zip","/CP071318.xml","/payload.json","/CP071318_VMw.zip/index.xml","/CP071318_VMw.zip/vendor-index.xml","/CP071318_VMw.zip/metadata.zip","/CP071318_VMw.zip/vib20/CP071318/HPE_bootbank_CP071318_CP071318.4-1OEM.900.0.24755229.vib","/CP071318_VMw.zip/metadata.zip/vendor-index.xml","/CP071318_VMw.zip/metadata.zip/vmware.xml","/CP071318_VMw.zip/metadata.zip/vibs/CP071318--6414400687397042827.xml","/CP071318_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071318_CP071318.4-1OEM.900.0.24755229.xml"],"Name":"CP071318.zip","SHA1Sum":"ac3a4b10b8b5f2480c72108bc04e8ffa0d69a95a","SHA256Sum":"98d7ec40e3dbb929dcdf3ab002a4a67d27453c1fb16ac8f65cd0fccad8c97479","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01","VibList":[{"Name":"CP071318","Version":"CP071318.4-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f18aaf340f6d4f549dfdc8b844","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.rpm","SHA1Sum":"82923536eeae167fff31cd772f84f315d3d26205","SHA256Sum":"5468cacd3c067de390ad2cc20c1ed37cbcd4e8298e793a8159a56a6fed573523","SHA512Sum":"daa74f9124ffffed42457bb10fc325e5d7fd66e852b039f668ca20e694bd76c9177ec1aac95ffe3dcf383a44a391be50279ca3af76522dec59f45e4b9b382484"}],"ComponentSizeInKB":78,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/72","./usr/lib/.build-id/72/a03a9ff597f1dea9a25195d6f5b808cbc1abc4","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/5557941ae1690cf046829593e05361a19f3ab5","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.rpm","SHA1Sum":"82923536eeae167fff31cd772f84f315d3d26205","SHA256Sum":"5468cacd3c067de390ad2cc20c1ed37cbcd4e8298e793a8159a56a6fed573523","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.rhel9u7.x86_64.rpm","SHA1Sum":"0b1881d829bd19d0ed9505644be7ebda8de7045d","SHA256Sum":"1589a5097173b4a7351377ffcf24a43a666dc54d4fc05485081ef89d31f78009","SHA512Sum":"566163602e6dd40b709ef0ec2cbd44fb2fb91d6244d508d8db3f38427fbd53ec782e4945863f42537a67f4a10bba7d246311b5d1245610d9066f5b450993570c"}],"ComponentSizeInKB":29832,"CompsigList":["mft-4.36.0-147.rhel9u7.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel9u7.x86_64.rpm","SHA1Sum":"0b1881d829bd19d0ed9505644be7ebda8de7045d","SHA256Sum":"1589a5097173b4a7351377ffcf24a43a666dc54d4fc05485081ef89d31f78009","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 7 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c67bdbe86684bc18826a10734","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"CP070924.zip","SHA1Sum":"d94a05f402e6b1c0ca0c733da595780dc11a36d4","SHA256Sum":"031ed4a301b48f6df33ccd4fbe2218595e78593b906a8b614131df2b69c33424","SHA512Sum":"75e24bd36826cbf32774385d7656cf1eb3c516ba890b4b74d0b86f44b2713d1a8781b7d1e5cf74b430803927cfc8a4e1a8b938420c552066a966d285e7c21704"}],"ComponentSizeInKB":19940,"CompsigList":["CP070924.compsig"],"FileList":["/CP070924_BUILD_4.data","/CP070924.vmexe64","/CP070924.vmfile","/CP070924_VMw.zip","/CP070924.xml","/payload.json","/CP070924_VMw.zip/index.xml","/CP070924_VMw.zip/vendor-index.xml","/CP070924_VMw.zip/metadata.zip","/CP070924_VMw.zip/vib20/CP070924/HPE_bootbank_CP070924_GPK8.4-8.0.0.20613240.vib","/CP070924_VMw.zip/metadata.zip/vendor-index.xml","/CP070924_VMw.zip/metadata.zip/vmware.xml","/CP070924_VMw.zip/metadata.zip/vibs/CP070924-1277334331218524609.xml","/CP070924_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070924_GPK8.4-8.0.0.20613240.xml"],"Name":"CP070924.zip","SHA1Sum":"d94a05f402e6b1c0ca0c733da595780dc11a36d4","SHA256Sum":"031ed4a301b48f6df33ccd4fbe2218595e78593b906a8b614131df2b69c33424","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP070924","Version":"GPK8.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a85bf349ded846479cba888747","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957412A4121HC.fwpkg","SHA1Sum":"2f129ef3d404c868fcf1c709217c81caa5e49c91","SHA256Sum":"e50e20bbc901f0f762196db4fee88c388f555c9d9420ad5f18b4a900e3a94e80","SHA512Sum":"ed8715d2ca24ba4ef0fa34a8e439bf40b8a6fabc7119e389f672bc90ee0db9350337568a93b088c8fb9357cb93ebd80242e8e7eb3e27e3171479c75944215fc7"}],"ComponentSizeInKB":1364,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957412A4121HC.HPb","BCM237.1.148.0_BCM957412A4121HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957412A4121HC.fwpkg","SHA1Sum":"2f129ef3d404c868fcf1c709217c81caa5e49c91","SHA256Sum":"e50e20bbc901f0f762196db4fee88c388f555c9d9420ad5f18b4a900e3a94e80","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57412 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57412_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_93cf50e4dca44a1e82c1eb2912","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08SDAnD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a575a5655","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","SHA512Sum":"44080d9266cd1d595e8996376f90a61e1d35aa6305c8210ac25cbb18b2ec570a5cc71ff630c778463b302b1e160d5b268badfeb282445b15936980078c561f07"}],"ComponentSizeInKB":1260,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAnD3.HPb","Toshiba_MG08Air_TAMG08SDAnD3.xml"],"Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a575a5655"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB004000JWZVU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWZVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb947df2b7494b02a1ae11bb03","SupportedDevices":["4d2340a5-3042-3430-3030-304a575a5655"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"237.1.148000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe-1.26.0-1.1.x86_64.rpm","SHA1Sum":"1d23539a1aa526c14214e91d91542203dae199ae","SHA256Sum":"6ba95e75ebce269955a3e7019b097d4d58dd12e7daabdf1e7d481c625d4c1836","SHA512Sum":"972c2e7ca72c386c6949030912e4f81523c3312b9aca57e65f9248fc22812eaf919168cf8e06251d4208da6a037ecbc898f86304c2613904c85ba06b5718cedb"}],"ComponentSizeInKB":7927,"CompsigList":["firmware-nic-bcm-nxe-1.26.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/CP071467.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/CP071467.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071467.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071467.scexe"],"Name":"firmware-nic-bcm-nxe-1.26.0-1.1.x86_64.rpm","SHA1Sum":"1d23539a1aa526c14214e91d91542203dae199ae","SHA256Sum":"6ba95e75ebce269955a3e7019b097d4d58dd12e7daabdf1e7d481c625d4c1836","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.26.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0da18d34ed414b029d7d154f03","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072099.zip","SHA1Sum":"60f0ce76ef48a4cc5f82508d5e2baae67d2693ba","SHA256Sum":"091b5c4428c0eb3444448da8e396e0be332bcc93f33a948c1635dc122d0196e6","SHA512Sum":"2264f5964cb4a04fe6d00e926b2415e24b147b9ff1d20bc5fdf20ccb66f669904a966934a797ad71aed769081f96508acccc4f7decfb299289649ed724044a41"}],"ComponentSizeInKB":13625,"CompsigList":["cp072099.compsig"],"FileList":["/cp072099.xml","/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip","/ssacli2-component_6.65.11.0-0.zip/index.xml","/ssacli2-component_6.65.11.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip","/ssacli2-component_6.65.11.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vibs/ssacli2--6784777076922694234.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.11.0-0.xml"],"Name":"cp072099.zip","SHA1Sum":"60f0ce76ef48a4cc5f82508d5e2baae67d2693ba","SHA256Sum":"091b5c4428c0eb3444448da8e396e0be332bcc93f33a948c1635dc122d0196e6","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.11.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.11.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec21b21fb0ac426b98b388e6a0","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069722.exe","SHA1Sum":"7721cc32a14c1b549e319c103e1b429d066fe5ae","SHA256Sum":"97a1759cfc9ae1322f870c31450e8e32333feedd2d53947745f12c2ead3f4241","SHA512Sum":"23783d34ada6f3c24a19105f151d43570b35740af5b8ab09696563e2d24346a51e2466d6ae7c811edda8c3599e04aeac1ea16b852f9ec5bde8af77d58f4412a6"}],"ComponentSizeInKB":566,"CompsigList":["cp069722.compsig"],"FileList":["cp069722.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp069722.exe","SHA1Sum":"7721cc32a14c1b549e319c103e1b429d066fe5ae","SHA256Sum":"97a1759cfc9ae1322f870c31450e8e32333feedd2d53947745f12c2ead3f4241","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_60c84d67122f4120814e871a3b","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","I44","U46","U46","U47","U47","U50","H08","H08","H10","H10","H10","U60","U61","U56","A42","A43","A43","A42","A48","U50","U39","U40","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070956.zip","SHA1Sum":"21c0afc183d123936ff5b2df66b692da2cb47361","SHA256Sum":"c15c52167860613925307bc387c4d81ac02a9ae187d58bfd0236da648fc2afbf","SHA512Sum":"faccbba8606b8a804e6aeb3e7dcd3c538113413f51d1a57bdae924464db657f0a1356d0b5afb09cf0bfb231144492dd2143a33037307a73b5baa5431880f429b"}],"ComponentSizeInKB":17704,"CompsigList":["CP070956.compsig"],"FileList":["/CP070956_BUILD_6.data","/CP070956.vmexe64","/CP070956.vmfile","/CP070956_VMw.zip","/CP070956.xml","/payload.json","/CP070956_VMw.zip/index.xml","/CP070956_VMw.zip/vendor-index.xml","/CP070956_VMw.zip/metadata.zip","/CP070956_VMw.zip/vib20/CP070956/HPE_bootbank_CP070956_HPD9.6-8.0.0.20613240.vib","/CP070956_VMw.zip/metadata.zip/vendor-index.xml","/CP070956_VMw.zip/metadata.zip/vmware.xml","/CP070956_VMw.zip/metadata.zip/vibs/CP070956-7036912924534481294.xml","/CP070956_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070956_HPD9.6-8.0.0.20613240.xml"],"Name":"CP070956.zip","SHA1Sum":"21c0afc183d123936ff5b2df66b692da2cb47361","SHA256Sum":"c15c52167860613925307bc387c4d81ac02a9ae187d58bfd0236da648fc2afbf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070956","Version":"HPD9.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb75fa0c275f484ab481512353","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"A41_3.80_05_28_2026.fwpkg","SHA1Sum":"ead527e8a7f8a8028e0369f10dd071d62bd69e20","SHA256Sum":"1cd9e9f0980e99fa86530736673043847bb1f777625c414c1f4cb7290869209b","SHA512Sum":"668b276c2c6e4329d297fe27acf07cb61ccbb6cd00a458dd3015dbef61b857388dbc40659a6b19bda356d4e76f6870b71af5ebc546b3709784b2f07db2e66075"}],"ComponentSizeInKB":32812,"CompsigList":[],"FileList":["A41_3.80_05_28_2026.signed.flash","A41_3.80_05_28_2026.xml","payload.json"],"Name":"A41_3.80_05_28_2026.fwpkg","SHA1Sum":"ead527e8a7f8a8028e0369f10dd071d62bd69e20","SHA256Sum":"1cd9e9f0980e99fa86530736673043847bb1f777625c414c1f4cb7290869209b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b870fdf47b434cfbaacd2d20df","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp064706.zip","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","SHA512Sum":"a46dadc4f72ea61052210d56d31900cedb3c167720ce272c3badd9f7edd852fcb4f702d0fa9e6ea751ab3049b30e450f5bf1b5faaf8f162cd727f083227adeb0"}],"ComponentSizeInKB":1486,"CompsigList":["cp064706.compsig"],"FileList":["/cp064706.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp064706.zip","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5b72663a36ec4ac2a8e3084a2a","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U38_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U38_3.66_04_01_2026.fwpkg","SHA1Sum":"9c148363c3e7ea32d0eb7f6a807790ea86d5c062","SHA256Sum":"d10727eaa62e630dc667f21c36314bf6bfd0b11d7f7ff5783568b89fe119753d","SHA512Sum":"fd22b0649f5550831d40032ed30e907b0f4384a4154bfc495a0c208dedb2cd76b1e01b98391f85e254024cf4bb0b9e5587b0beebb425c2952a283c86f5674572"}],"ComponentSizeInKB":32822,"CompsigList":[],"FileList":["payload.json","U38_3.66_04_01_2026.signed.flash","U38_3.66_04_01_2026.xml"],"Name":"U38_3.66_04_01_2026.fwpkg","SHA1Sum":"9c148363c3e7ea32d0eb7f6a807790ea86d5c062","SHA256Sum":"d10727eaa62e630dc667f21c36314bf6bfd0b11d7f7ff5783568b89fe119753d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c69015cdaa1244d18ed971f8d3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047575a564c","Version":"HPG3"},{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-3047575a564e","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","SHA512Sum":"d73c1366eba27fab03a6f3631e2afaf9f70034f1f7c387ccd881efc5c049da84e3d78743ed1d275a9f8dc8b618f3ca6ff4fe077f974bc8de16fd9bf739831256"}],"ComponentSizeInKB":1252,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAeG3.HPb","Toshiba_MG08Air_TAMG08ADAeG3.xml"],"Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"TypeOfChange":"2","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWZVL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GWZVN","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22b25cb7056247fca6f226ad38","SupportedDevices":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-acce-2.1.0-1.1.x86_64.rpm","SHA1Sum":"944226d81c89175d2c31d3f8abe512e1555c435e","SHA256Sum":"1a94721a37f812da60e5086be7587911b72ffe90591c84b71f4e9bce41073f26","SHA512Sum":"428f0cab9d6c962c0f9fd371c9cdd42eb7a32adc7499ed9e036de1c2433349bbc8ab28117abfb0a088604379eec2fef57be5d2567bfe34ebc641f704a16354cd"}],"ComponentSizeInKB":425,"CompsigList":["firmware-acce-2.1.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/ACCE_2.1.0s.bin","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/CP072093.xml","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072093.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072093.scexe"],"Name":"firmware-acce-2.1.0-1.1.x86_64.rpm","SHA1Sum":"944226d81c89175d2c31d3f8abe512e1555c435e","SHA256Sum":"1a94721a37f812da60e5086be7587911b72ffe90591c84b71f4e9bce41073f26","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Edgeline Chassis Controller Firmware","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bf0ec337c7584124b52b426e0a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","HPE Edgeline EL8000t Converged Edge System","FTP","H10","H11","H11"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070983.zip","SHA1Sum":"dbdf5b2b0aa1922e33b00ce32f4e12c0eb02cc40","SHA256Sum":"c7cff4643fe45fc1d87475bd32e358bbe45b15a866f9b3ff53da4bece870c313","SHA512Sum":"aae0430fa0ba2ccbfdf95924449fa8b22cdc7999a1ca88315a174007dd437705a25e5f6f208a4932580693c19b8c7f188ada10769b35b552cf10362f525883a1"}],"ComponentSizeInKB":18464,"CompsigList":["CP070983.compsig"],"FileList":["/CP070983_BUILD_2.data","/CP070983.vmexe64","/CP070983.vmfile","/CP070983_VMw.zip","/CP070983.xml","/payload.json","/CP070983_VMw.zip/index.xml","/CP070983_VMw.zip/vendor-index.xml","/CP070983_VMw.zip/metadata.zip","/CP070983_VMw.zip/vib20/CP070983/HPE_bootbank_CP070983_HPD2.2-8.0.0.20613240.vib","/CP070983_VMw.zip/metadata.zip/vendor-index.xml","/CP070983_VMw.zip/metadata.zip/vmware.xml","/CP070983_VMw.zip/metadata.zip/vibs/CP070983--2246090989153402999.xml","/CP070983_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070983_HPD2.2-8.0.0.20613240.xml"],"Name":"CP070983.zip","SHA1Sum":"dbdf5b2b0aa1922e33b00ce32f4e12c0eb02cc40","SHA256Sum":"c7cff4643fe45fc1d87475bd32e358bbe45b15a866f9b3ff53da4bece870c313","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070983","Version":"HPD2.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3b8ba904ca745178e3f0fb5c3","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.3.0-1.rhel9u6.x86_64.rpm","SHA1Sum":"a7552549c54f186417e0e56902a75954c207a072","SHA256Sum":"91542c34487b45479928e72926918f5ed6d942646137f0273c02d86f86d947f5","SHA512Sum":"14bdb411155d497faaeb98cd5b37220a62186b64f93bd70af036b5678ca9ba19caf83c5e3e50b20b0b66986cecc5ffdd7fdbcfae8144e191ec52798daddb14d3"}],"ComponentSizeInKB":17319,"CompsigList":["kmod-qlgc-fastlinq-8.76.3.0-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.3.0-1.rhel9u6.x86_64.rpm","SHA1Sum":"a7552549c54f186417e0e56902a75954c207a072","SHA256Sum":"91542c34487b45479928e72926918f5ed6d942646137f0273c02d86f86d947f5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.3.0-5"},{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.3.0-5.rhel9u7.x86_64.rpm","SHA1Sum":"7eac92b79bf6cf6763df68072f93a8ec8aece1c2","SHA256Sum":"7740bbc87295c31a0bebf09c9980940a97273909b547b423fedf0b7a2f99d9f4","SHA512Sum":"4c4bb52778950550b05d7192f4630a83e8d261eb3f73a65e9e796f990a9a5c803c3c0e17eee2a8a1774810e46e408a871066b02dd10529072049e2bfadc7b94a"}],"ComponentSizeInKB":17346,"CompsigList":["kmod-qlgc-fastlinq-8.76.3.0-5.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.3.0-5.rhel9u7.x86_64.rpm","SHA1Sum":"7eac92b79bf6cf6763df68072f93a8ec8aece1c2","SHA256Sum":"7740bbc87295c31a0bebf09c9980940a97273909b547b423fedf0b7a2f99d9f4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.3.0-5"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_25e533cd884842babd4aad15d0","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"cp067914.exe","SHA1Sum":"77ab5498ec7d3ab143561e871d5d1f51cbaaeafb","SHA256Sum":"53c2faf21729c4da78199d8771a62fb9e794a9590231cf3f7a99e98533233260","SHA512Sum":"f1be145743e997726cfa3584373f4c946e40b3af1e619d7d045bcfb0f4f50340713f47ba7634203de9b93ebed16ec00919d5cc401b9b1b94923ad3804ccd2a82"}],"ComponentSizeInKB":3661,"CompsigList":["cp067914.compsig"],"FileList":["Capitola-Release-1.27.bin.fw","cp067914.xml","cpqsetup.exe","payload.json","setup.dll"],"Name":"cp067914.exe","SHA1Sum":"77ab5498ec7d3ab143561e871d5d1f51cbaaeafb","SHA256Sum":"53c2faf21729c4da78199d8771a62fb9e794a9590231cf3f7a99e98533233260","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5bd325460cd446faaf9c162a70","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068745.exe","SHA1Sum":"4300ba45137ca9d5ca2f23d343fe5b6de983305d","SHA256Sum":"e494903936f32cfdaf01a3849a9feba1b0c1d68686338fef8b1d750d489d32f5","SHA512Sum":"fe501777c73fa63af18b44df411ff4659fa4306be2686111351dbd32cb44f1e7925c8217a9473d236cbb929fa96799b27d59ad57b631f72f013f945c637cb586"}],"ComponentSizeInKB":4316,"CompsigList":["cp068745.compsig"],"FileList":["cp068745.xml","cpqsetup.exe","HVLPeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068745.exe","SHA1Sum":"4300ba45137ca9d5ca2f23d343fe5b6de983305d","SHA256Sum":"e494903936f32cfdaf01a3849a9feba1b0c1d68686338fef8b1d750d489d32f5","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcfbab82abed4237b56f417784","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM6 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_UBM6_1.06_B.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9675b54e-1c96-44c3-a7a1-901506000000","Version":"1.06"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM6_1.06_B.fwpkg","SHA1Sum":"37498e5d53d0413ec0dddaacfcc030a9e13d5f1c","SHA256Sum":"8b74227dbf99303c057f896a5ee43adeee42a70dbe8ec83fa0168f8c5de3acc0","SHA512Sum":"ce907e977a58659763914d688cef016966d62ecb46c27e90f859eab38755ef6bd7962eba6cf3bcf1b5785364791584b325ba4f4e84949577b92e67ea07ba42df"}],"ComponentSizeInKB":128,"CompsigList":[],"FileList":["HPE_UBM6_1.06_B.HPb","HPE_UBM6_1.06_B.xml","payload.json"],"Name":"HPE_UBM6_1.06_B.fwpkg","SHA1Sum":"37498e5d53d0413ec0dddaacfcc030a9e13d5f1c","SHA256Sum":"8b74227dbf99303c057f896a5ee43adeee42a70dbe8ec83fa0168f8c5de3acc0","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901506000000"],"TypeOfChange":"1","Version":"1.06"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM6PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a8fa943c5e2c47098e12c28864","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A56","A56","A55","A55","U54","U54","U54","U63","U58","U63","U59","I45","U46","U30","A42","U46","U32","A43","A43","A42","U46","U69","R11","U71","U71","U68","U68","U72","U68","I46"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"CP070907.zip","SHA1Sum":"88abb62eb7a0dacea43ddf88264fbaad68478beb","SHA256Sum":"3e328df1020bdcd16c62f11f074f4ce26710dc75b589df1847e13002517853fa","SHA512Sum":"1846b33f7bcb7b50e28dbe31771d7dbdae0cbdd16ed6430f4307af3c6ef0e1e44631b1bab1187183d3b1117186668a8bae18ed0b337ec44bd337867c87505e0e"}],"ComponentSizeInKB":22034,"CompsigList":["CP070907.compsig"],"FileList":["/CP070907_BUILD_2.data","/CP070907.vmexe64","/CP070907.vmfile","/CP070907_VMw.zip","/CP070907.xml","/payload.json","/CP070907_VMw.zip/index.xml","/CP070907_VMw.zip/vendor-index.xml","/CP070907_VMw.zip/metadata.zip","/CP070907_VMw.zip/vib20/CP070907/HPE_bootbank_CP070907_HPK5.2-8.0.0.20613240.vib","/CP070907_VMw.zip/metadata.zip/vendor-index.xml","/CP070907_VMw.zip/metadata.zip/vmware.xml","/CP070907_VMw.zip/metadata.zip/vibs/CP070907--7255520009019874989.xml","/CP070907_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070907_HPK5.2-8.0.0.20613240.xml"],"Name":"CP070907.zip","SHA1Sum":"88abb62eb7a0dacea43ddf88264fbaad68478beb","SHA256Sum":"3e328df1020bdcd16c62f11f074f4ce26710dc75b589df1847e13002517853fa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5","VibList":[{"Name":"CP070907","Version":"HPK5.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2c4dff857fb48b7a0f421efe2","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8b26d1ef02_0HPD2-2.1_amd64.deb","SHA1Sum":"fed72f55ea3b72baf688e22b7c287b87b2dd786c","SHA256Sum":"1d4a5f251497b1ee2ee3c17e903bafb4677c9b1e13454b4cefac5631f9b156c4","SHA512Sum":"80ee4145095ef0f36540453eb0001515b8e4153c6693b962b32b63a4328e6e8ab0de29a83d8cce158a9da92c4086d96d89e8459c25ba8a34f9e99ab8ccc61c6c"}],"ComponentSizeInKB":4545,"CompsigList":["firmware-hdd-8b26d1ef02_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/CP071733.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071733.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071733.scexe"],"Name":"firmware-hdd-8b26d1ef02_0HPD2-2.1_amd64.deb","SHA1Sum":"fed72f55ea3b72baf688e22b7c287b87b2dd786c","SHA256Sum":"1d4a5f251497b1ee2ee3c17e903bafb4677c9b1e13454b4cefac5631f9b156c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9fb45235d0ac4a3fb1067b2f1f","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.deb","SHA1Sum":"8af87e104b47843e11399b876e4dee746e29bb73","SHA256Sum":"eb899e2c76f4eac16aafb6f76e66fc4fb35ba5879491ab29984303b20e9c69a6","SHA512Sum":"f3276f165e176b5e56ae162154c747e4cd47160d72d797ba1f4b542d24b10a381e4e92b124911fc925347704c3b4f7cc7f190f1a70b9fe716efeddb0b010324d"}],"ComponentSizeInKB":3020,"CompsigList":["firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/CP071740.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071740.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071740.scexe"],"Name":"firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.deb","SHA1Sum":"8af87e104b47843e11399b876e4dee746e29bb73","SHA256Sum":"eb899e2c76f4eac16aafb6f76e66fc4fb35ba5879491ab29984303b20e9c69a6","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_236dc077387a4562b1c1d010c8","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957504-P425H.fwpkg","SHA1Sum":"5394c9ac0d5d205203fc318086b6213af1bc5e4d","SHA256Sum":"0d64470382ba6187a4d248003378132f1562c0543f31de2d57ab1c552d64ea76","SHA512Sum":"e2c0f8acb3b5ed8758e3f5c1da9684a51f25f6368ca72e93920507c84bb60cd1b353f58346253372369c6e42a0e8232f454dd32d45543b8b8b04d21abfdb3176"}],"ComponentSizeInKB":2870,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957504-P425H.HPb","BCM237.1.148.0_BCM957504-P425H.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957504-P425H.fwpkg","SHA1Sum":"5394c9ac0d5d205203fc318086b6213af1bc5e4d","SHA256Sum":"0d64470382ba6187a4d248003378132f1562c0543f31de2d57ab1c552d64ea76","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57504_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd24de447b3b45588daf0d34bb","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-175114e41599"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","SHA1Sum":"1ebfb22617bc4dfa29bc9d8fe385660f78e62222","SHA256Sum":"f919ff081a5d4dccf19206007cfe57312401a73fbf89ff041b186cbac33aa20f","SHA512Sum":"4acf16d2b6b94ce6bbf8cccbb20df08c3e7345024aeee191e43c9f557a3e96dc7ae7412e1060a3bd6fa373bc9868f60167393ca1eab50a3e10c45649124bb435"}],"ComponentSizeInKB":5002,"CompsigList":["firmware-hdd-852266afdf-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/CP068866.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068866.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068866.scexe"],"Name":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","SHA1Sum":"1ebfb22617bc4dfa29bc9d8fe385660f78e62222","SHA256Sum":"f919ff081a5d4dccf19206007cfe57312401a73fbf89ff041b186cbac33aa20f","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_56f020a0165144c8989c5eba4a","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_OCP3_9p56_CFGID7p2_K97342_800100D3.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3909.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_9p56_CFGID7p2_K97470_800100DE.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"}]},"Files":[{"Checksum":[{"Filename":"cp070392.exe","SHA1Sum":"248086b065cd46d5bae42611a84e2b5fd6b33b12","SHA256Sum":"c879d076575ac8b8fe3ba11dd858e7eab0856e0d7630faf277005f5fdae2204c","SHA512Sum":"6d60f1f9843bc88bf7cccfbcd692b86595c252578b97bab2e0566fd7ad17bfdbcb4c16edb2a467e2942e7ed8f620fc6a4bec6fc2f2d9daf55922657385ceab53"}],"ComponentSizeInKB":7027,"CompsigList":["cp070392.compsig"],"FileList":["cp070392.xml","cpqsetup.exe","FW/","FW/BootIMG_ISA.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP_ISA.txt","FW/HPE_i350T4_K68277_8000123F.txt","FW/HPE_i350T4_OCP_K53978_80001234.txt","FW/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","FW/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","FW/HPE_X710DA2_9p56_CFGID7p2_K97470_800100DE.bin","FW/HPE_X710DA2_OCP3_9p56_CFGID7p2_K97342_800100D3.bin","FW/HPE_X710_DA_OCP3_EEPROM_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp070392.exe","SHA1Sum":"248086b065cd46d5bae42611a84e2b5fd6b33b12","SHA256Sum":"c879d076575ac8b8fe3ba11dd858e7eab0856e0d7630faf277005f5fdae2204c","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"5.4.7.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_af1dca40ea14406c99ff8d8fa1","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f36d4ef431_0.39-2.1_amd64.deb","SHA1Sum":"afc5fbd46fc73decc95db8e0bbfa2289655dcb76","SHA256Sum":"7aba29e686eb580a785ff3207ce2b9118b582eec106a6fb3d1dfa23fe1f634d4","SHA512Sum":"739ba0fc9840e7011faa50c511e02afa227aac310c7a63db8aea2e79e7d6874389ac473fa42ad2f10bdde476aef91efab4a15ee792569feac70a720ecfb74e1e"}],"ComponentSizeInKB":3265,"CompsigList":["firmware-smartarray-f36d4ef431_0.39-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/CP071701.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071701.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071701.scexe"],"Name":"firmware-smartarray-f36d4ef431_0.39-2.1_amd64.deb","SHA1Sum":"afc5fbd46fc73decc95db8e0bbfa2289655dcb76","SHA256Sum":"7aba29e686eb580a785ff3207ce2b9118b582eec106a6fb3d1dfa23fe1f634d4","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66f0df2fb5c049d894d56c7cfb","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U50","U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-237.1.137.0.sles15sp6.x86_64.rpm","SHA1Sum":"957d86ecba5db496fffcf1ce00b9cdae82e6bbfd","SHA256Sum":"94494f28b36a8e3d61669c209c647dd3c0c5f943cff494ab7f015034c660600a","SHA512Sum":"d0e6b03225b8689df9b9b1e94dbdd7ba77156e9d5fe76d42f1e130aab01c86274883f745fc21035b3476c6b5b20c792f7fc37d9bb93002c1652c8f7e1970bd6c"}],"ComponentSizeInKB":1225,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-237.1.137.0.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-237.1.137.0.sles15sp6.x86_64.rpm","SHA1Sum":"957d86ecba5db496fffcf1ce00b9cdae82e6bbfd","SHA256Sum":"94494f28b36a8e3d61669c209c647dd3c0c5f943cff494ab7f015034c660600a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"},{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-237.1.137.0.sles15sp7.x86_64.rpm","SHA1Sum":"f60122135ac332f76962521a15769ee6638a9dbd","SHA256Sum":"a9c3805a589631281dc9df8a88ce134773878f002562569d6ab84d45631e16da","SHA512Sum":"7953534ea2dbf926ec793f930b262b62a2d9cd3a3f622699680739cccf2301594b3737c1f871367d651ad3ba2a54ac4e946992037de0ab54b03f4df79f450a05"}],"ComponentSizeInKB":1234,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-237.1.137.0.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-237.1.137.0.sles15sp7.x86_64.rpm","SHA1Sum":"f60122135ac332f76962521a15769ee6638a9dbd","SHA256Sum":"a9c3805a589631281dc9df8a88ce134773878f002562569d6ab84d45631e16da","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7bb902e5251340c48df175a572","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068736.exe","SHA1Sum":"d2555ff54cbe38ca56f7ae1fcdc9698cc9708ae2","SHA256Sum":"1d8695c16716ee1f7ac34baccdeaa9f78e3bd81d8ba3e1cd872c0b7e993c4db2","SHA512Sum":"2270d275486e440dc0e39ebc1cf29d7b23665e4cf457cb65cd254b04efc4ecafcb4840119e50627cef6cbbdb19ad522ca46e92bfa657a9bbf9cd65dcae67c519"}],"ComponentSizeInKB":4404,"CompsigList":["cp068736.compsig"],"FileList":["cp068736.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPNSD6.rel","setup.dll"],"Name":"cp068736.exe","SHA1Sum":"d2555ff54cbe38ca56f7ae1fcdc9698cc9708ae2","SHA256Sum":"1d8695c16716ee1f7ac34baccdeaa9f78e3bd81d8ba3e1cd872c0b7e993c4db2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_98f0ab5aa0074cff977bf2a348","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp070058.exe","SHA1Sum":"66d0faf63ec3031c65dd7fe366947041cccd4a2a","SHA256Sum":"7ebfa3197ebc7db127870af975b864c84d8ba1356a5d748708a925d710f73d4f","SHA512Sum":"5a52d50b7d0060275abaf8d255bf9f62b1d9b1c016a9584ee9e6fa474ad357410ce9bc4ea834d2370fb2420f74d7852fbfffe33e3be8d5e53fa749e9eedb775a"}],"ComponentSizeInKB":4082,"CompsigList":["cp070058.compsig"],"FileList":["cp070058.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09scHPD6.REL"],"Name":"cp070058.exe","SHA1Sum":"66d0faf63ec3031c65dd7fe366947041cccd4a2a","SHA256Sum":"7ebfa3197ebc7db127870af975b864c84d8ba1356a5d748708a925d710f73d4f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f811131bece14cf8bf32f4ab99","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-852266afdf_0HPD6-2.1_amd64.deb","SHA1Sum":"0e7a0df2284e331c6ff6520a9ca5a97b98769415","SHA256Sum":"bb65e144aed79b86d9f60f6679357f402c044e22f821105e264c838d1eb684f5","SHA512Sum":"334863ad46db3fbf52e23bb8a7a4b6e29d7f7f5aba88a417344b6e1bbd4aa10152a83fb3022b04cff6dab9122db047d4e8b287fbdae325ff3581ba2bc6a428e4"}],"ComponentSizeInKB":3472,"CompsigList":["firmware-hdd-852266afdf_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/CP071765.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071765.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071765.scexe"],"Name":"firmware-hdd-852266afdf_0HPD6-2.1_amd64.deb","SHA1Sum":"0e7a0df2284e331c6ff6520a9ca5a97b98769415","SHA256Sum":"bb65e144aed79b86d9f60f6679357f402c044e22f821105e264c838d1eb684f5","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b6f4fc0cfd7b45808926f3cdb3","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_2CQDA2_O_SEC_4p91_PLDMoMCTP_800214AE.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_2CQDA2_O_SEC_4p91_PLDMoMCTP_800214AE.fwpkg","SHA1Sum":"f5657e85e2f1f073eb12ace185b6fd0892347798","SHA256Sum":"275d2d808cf768afcb2654db14ce2766e7e55a9c40518cbb1d67bc54f4f2f626","SHA512Sum":"57fc538b7b154e5e31f823d05ead73d41e067202dff3bbbddc4f4ce98dd6a7cfb397af17436571ac2e47ec50043114a3bd0f521a7899c56e91c2d716ad82763d"}],"ComponentSizeInKB":10279,"CompsigList":[],"FileList":["HPE_E810_2CQDA2_O_SEC_4p91_PLDMoMCTP_800214AE.HPb","HPE_E810_2CQDA2_O_SEC_4p91_PLDMoMCTP_800214AE.xml","payload.json"],"Name":"HPE_E810_2CQDA2_O_SEC_4p91_PLDMoMCTP_800214AE.fwpkg","SHA1Sum":"f5657e85e2f1f073eb12ace185b6fd0892347798","SHA256Sum":"275d2d808cf768afcb2654db14ce2766e7e55a9c40518cbb1d67bc54f4f2f626","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_526837a94da34ff39f8183978e","SupportedDevices":["a6b1a447-382a-5a4f-8086-15928086000e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","15.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070923.zip","SHA1Sum":"2c900cf6a82272494a55712ffd7ad7dc3b07aab2","SHA256Sum":"ce5530ce8fc220ffe243cfe71eb58c0ec0cf100ea8661c4c60ccd7580437a600","SHA512Sum":"5acdaf2db78f163541b4f86b9302f35e15c52ac1d681c032600c49d48398aa34dea26537d46ec3dedaf285c63d19b52522818a43c4e473462095a0cc199f7dce"}],"ComponentSizeInKB":20932,"CompsigList":["CP070923.compsig"],"FileList":["/CP070923_BUILD_2.data","/CP070923.vmexe64","/CP070923.vmfile","/CP070923_VMw.zip","/CP070923.xml","/payload.json","/CP070923_VMw.zip/index.xml","/CP070923_VMw.zip/vendor-index.xml","/CP070923_VMw.zip/metadata.zip","/CP070923_VMw.zip/vib20/CP070923/HPE_bootbank_CP070923_HPG1.2-8.0.0.20613240.vib","/CP070923_VMw.zip/metadata.zip/vendor-index.xml","/CP070923_VMw.zip/metadata.zip/vmware.xml","/CP070923_VMw.zip/metadata.zip/vibs/CP070923-9035409907771952477.xml","/CP070923_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070923_HPG1.2-8.0.0.20613240.xml"],"Name":"CP070923.zip","SHA1Sum":"2c900cf6a82272494a55712ffd7ad7dc3b07aab2","SHA256Sum":"ce5530ce8fc220ffe243cfe71eb58c0ec0cf100ea8661c4c60ccd7580437a600","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070923","Version":"HPG1.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives.","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba8fd5a6656246d3a58f5f6849","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b59445a4b","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59445a52","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59445a54","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59445a55","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b59445a48","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3533-364b59445a51","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59445a4c","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59445a4e","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59445a50","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Micron_7500_M7500ALLHPK6.fwpkg","SHA1Sum":"18ba68fc65ddb89dea4a3d13bd3fb4eb9f5b2b62","SHA256Sum":"72971fa3e44ffaae8a7d590fd3226c4f1a2532e2f815b6ceb32199bfcebab5d1","SHA512Sum":"a4073cd4499900e720746ee01280b488ea36cafe782d3f0d60373943f0356a4154f986a24bee250419419e2ae5f324190673e15f0c643c54905b6159062c6ab6"}],"ComponentSizeInKB":2206,"CompsigList":[],"FileList":["Micron_7500_M7500ALLHPK6.HPb","Micron_7500_M7500ALLHPK6.xml","payload.json"],"Name":"Micron_7500_M7500ALLHPK6.fwpkg","SHA1Sum":"18ba68fc65ddb89dea4a3d13bd3fb4eb9f5b2b62","SHA256Sum":"72971fa3e44ffaae8a7d590fd3226c4f1a2532e2f815b6ceb32199bfcebab5d1","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b59445a4b","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3630-3430-304b59445a55","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3730-3638-304b59445a50"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800KYDZK","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KYDZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYDZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYDZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KYDZH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYDZL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYDZN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYDZP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001536KYDZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fc0c2a18b79a47bdbb56ae5857","SupportedDevices":["4d2340a5-304f-3630-3430-304b59445a55","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3030-3830-304b59445a4b","562340a5-304f-3730-3638-304b59445a50","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"237.1.148000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe_1.26.0-1.1_amd64.deb","SHA1Sum":"f5057892a32fe411807379ebc5caecc90be10e0b","SHA256Sum":"dcf1116088a34bf3f6ff8ea69bf85160021d3432848b6f61e2f89a6cba840292","SHA512Sum":"e24a9be6f6fb4e291c865cfe6e294e6624ce2dee8f58ad4f53f40c7fad24552fdb3b79ca6ffc51efd8fb98bfaae210e46c46db2f4e7120724deed340997d640c"}],"ComponentSizeInKB":1382,"CompsigList":["firmware-nic-bcm-nxe_1.26.0-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/CP071466.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/CP071466.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071466.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.26.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071466.scexe"],"Name":"firmware-nic-bcm-nxe_1.26.0-1.1_amd64.deb","SHA1Sum":"f5057892a32fe411807379ebc5caecc90be10e0b","SHA256Sum":"dcf1116088a34bf3f6ff8ea69bf85160021d3432848b6f61e2f89a6cba840292","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.26.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for deb Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a84e141687464f1a85baa9afb2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp062283.exe","SHA1Sum":"03cb53f778f555f25c0e1ff6e170779708406c66","SHA256Sum":"ba00e35789e7eb8272ff04131763e9c8b7f798aa3c322ba9a2ea09a9c74c6a3a","SHA512Sum":"456a0b4372d480e533f16c84e0cd9ab7e47d50b254242ba7fd042fd33bf4556d61ec5cc2f477a12b55249008fc5bab90a11fd8d9e6af8ef40c5435c3ad767870"}],"ComponentSizeInKB":562,"CompsigList":["cp062283.compsig"],"FileList":["cp062283.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"Name":"cp062283.exe","SHA1Sum":"03cb53f778f555f25c0e1ff6e170779708406c66","SHA256Sum":"ba00e35789e7eb8272ff04131763e9c8b7f798aa3c322ba9a2ea09a9c74c6a3a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"InstallationDependency":{},"Name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07a6f72217b54f3fa879777aa7","SupportedDevices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I44","A47","A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"CP070868.zip","SHA1Sum":"30ff74b44b224c08505f24534f56f4afb2c73194","SHA256Sum":"d0d511df2501b1c205de724fb8121ee82b1b77767197ab29d94373ba3869d7a2","SHA512Sum":"5b8e6607d9d7a30c063bde67e28a3527f975bc63657c025d483a9632636f9a70e29b203b405d1ce182c2ea2e3db9b9d40626546a08d7561702bae0bb834ccfe3"}],"ComponentSizeInKB":17111,"CompsigList":["CP070868.compsig"],"FileList":["/CP070868_BUILD_3.data","/CP070868.vmexe","/CP070868.vmexe64","/CP070868.vmfile","/CP070868_VMw.zip","/CP070868.xml","/payload.json","/CP070868_VMw.zip/index.xml","/CP070868_VMw.zip/vendor-index.xml","/CP070868_VMw.zip/metadata.zip","/CP070868_VMw.zip/vib20/CP070868/HPE_bootbank_CP070868_5.15.3-8.0.0.20613240.vib","/CP070868_VMw.zip/metadata.zip/vendor-index.xml","/CP070868_VMw.zip/metadata.zip/vmware.xml","/CP070868_VMw.zip/metadata.zip/vibs/CP070868-7075707163769057284.xml","/CP070868_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070868_5.15.3-8.0.0.20613240.xml"],"Name":"CP070868.zip","SHA1Sum":"30ff74b44b224c08505f24534f56f4afb2c73194","SHA256Sum":"d0d511df2501b1c205de724fb8121ee82b1b77767197ab29d94373ba3869d7a2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15","VibList":[{"Name":"CP070868","Version":"5.15.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7db5b7e04388458db3d1228278","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssacli-6.65-9.0.x86_64.rpm","SHA1Sum":"a2db3332734d81af7eb6f7c1bd41822b69d34570","SHA256Sum":"a3b9f01aea3532da9e9539d15d888814e006faf1086b7022c10d7c788657b26d","SHA512Sum":"5ae1bd8a3c509a2b6ccc59023ea598923f77f71233e5961d54acca2c89d7dee9dee2c8cf3dee0f34fa2e667b1421bf3cb080cbc1f0c1a4a332e8c473bd7dcb53"}],"ComponentSizeInKB":12953,"CompsigList":["ssacli-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.65-9.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"Name":"ssacli-6.65-9.0.x86_64.rpm","SHA1Sum":"a2db3332734d81af7eb6f7c1bd41822b69d34570","SHA256Sum":"a3b9f01aea3532da9e9539d15d888814e006faf1086b7022c10d7c788657b26d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f20df565e4f4f60a5b5d0887b","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U63","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.deb","SHA1Sum":"ce35ff97b5281b74988e4f7fece31a08c2bafd73","SHA256Sum":"8231942422d5cd383457895f658bdfd8d969e45c81786d79abd3cab15ddd7ff5","SHA512Sum":"6cd1ae627c50e3357a9f8a3d90a376987b1cff061f037bc15eec6ad1375b0d380622d8e3f88a024069657b31503aee455e783a1d7fb23890c323f696a8ffd2f5"}],"ComponentSizeInKB":3383,"CompsigList":["firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/CP071713.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071713.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071713.scexe"],"Name":"firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.deb","SHA1Sum":"ce35ff97b5281b74988e4f7fece31a08c2bafd73","SHA256Sum":"8231942422d5cd383457895f658bdfd8d969e45c81786d79abd3cab15ddd7ff5","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Supplemental Update / Online ROM Flash Component for Ubuntu – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7131ee6d05744824b0805744c4","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070555.exe","SHA1Sum":"78b0b2d0736d26c2aa68e9bfeca9f06a4ae2085d","SHA256Sum":"215203314afb9899adc67e1fb5347c69bec2fad46c4712dc3c6e08bae2167521","SHA512Sum":"c9dcebd661639b0bd6e377a37b8ec752b564d362e19177f51288e977f68dc32c2fff780d6ee0dc2e19e53be5331b6cf7042420fe021351d0207a7ff5d5e4b27a"}],"ComponentSizeInKB":1220,"CompsigList":["cp070555.compsig"],"FileList":["cp070555.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070555.exe","SHA1Sum":"78b0b2d0736d26c2aa68e9bfeca9f06a4ae2085d","SHA256Sum":"215203314afb9899adc67e1fb5347c69bec2fad46c4712dc3c6e08bae2167521","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.24.42.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d2fd896f68c4ac6aee31f377b","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U32_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071383.exe","SHA1Sum":"a72898b8734dec3d42fe83e998d26998d69bb690","SHA256Sum":"9c17a1f5d85f12aff12da32e78463a2d7f857788418ba54f3ae0813d58d74a45","SHA512Sum":"7528ad0e195345f2a4c435dbd6b31ed421fcfdf48ccec3097864f25a3807b8ed00c17e250d9d29eb5b0915990d7e2104d03ccca3291c77abddf0014dfbb8335b"}],"ComponentSizeInKB":11561,"CompsigList":["cp071383.compsig"],"FileList":["cp071383.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_3.66_04_01_2026.signed.flash"],"Name":"cp071383.exe","SHA1Sum":"a72898b8734dec3d42fe83e998d26998d69bb690","SHA256Sum":"9c17a1f5d85f12aff12da32e78463a2d7f857788418ba54f3ae0813d58d74a45","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1ccbe759a426464b8f451d658c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070973.zip","SHA1Sum":"430a4cafaf15db210e1ec798b78944b959f94d08","SHA256Sum":"9a61c74e3a2731eeb35158351c982178da6170b4608e98a6d5ff313f9d9dd2cf","SHA512Sum":"98cb6947051fedf9a945e8dcfdf64b7a540aa03f814b4693c5212eab379b75e5ae9241d0b3f30dd0965f892d12719685e357263740903ec52d0dbac8594f5ce2"}],"ComponentSizeInKB":19839,"CompsigList":["CP070973.compsig"],"FileList":["/CP070973_BUILD_1.data","/CP070973.vmexe64","/CP070973.vmfile","/CP070973_VMw.zip","/CP070973.xml","/payload.json","/CP070973_VMw.zip/index.xml","/CP070973_VMw.zip/vendor-index.xml","/CP070973_VMw.zip/metadata.zip","/CP070973_VMw.zip/vib20/CP070973/HPE_bootbank_CP070973_HPD3.1-8.0.0.20613240.vib","/CP070973_VMw.zip/metadata.zip/vendor-index.xml","/CP070973_VMw.zip/metadata.zip/vmware.xml","/CP070973_VMw.zip/metadata.zip/vibs/CP070973-8686616375770771222.xml","/CP070973_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070973_HPD3.1-8.0.0.20613240.xml"],"Name":"CP070973.zip","SHA1Sum":"430a4cafaf15db210e1ec798b78944b959f94d08","SHA256Sum":"9a61c74e3a2731eeb35158351c982178da6170b4608e98a6d5ff313f9d9dd2cf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070973","Version":"HPD3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b23aee1aa6a4d6b9845af9a57","SupportedDevices":["4d2340a5-3042-3831-3030-304a584d5448","4d2340a5-3042-3032-3030-304a584d5450"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070965.zip","SHA1Sum":"fb35fca5349fa508fba7abf4d29fe8c9a9275b28","SHA256Sum":"cf9e99f5f3d5e36f16636374f4f88e0212fa306b7cfba5057585c5b8470a6141","SHA512Sum":"d0a324230014c4f451c161b259a50fef38e95bff67c7277e0e28ed083c7df1913559d5f401cfb5be60d2cd349f9e50187bf6962a0d7dfa1a3c12531a00ce05f8"}],"ComponentSizeInKB":20416,"CompsigList":["CP070965.compsig"],"FileList":["/CP070965_BUILD_3.data","/CP070965.vmexe64","/CP070965.vmfile","/CP070965_VMw.zip","/CP070965.xml","/payload.json","/CP070965_VMw.zip/index.xml","/CP070965_VMw.zip/vendor-index.xml","/CP070965_VMw.zip/metadata.zip","/CP070965_VMw.zip/vib20/CP070965/HPE_bootbank_CP070965_HPG3.3-8.0.0.20613240.vib","/CP070965_VMw.zip/metadata.zip/vendor-index.xml","/CP070965_VMw.zip/metadata.zip/vmware.xml","/CP070965_VMw.zip/metadata.zip/vibs/CP070965--9132676996004971802.xml","/CP070965_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070965_HPG3.3-8.0.0.20613240.xml"],"Name":"CP070965.zip","SHA1Sum":"fb35fca5349fa508fba7abf4d29fe8c9a9275b28","SHA256Sum":"cf9e99f5f3d5e36f16636374f4f88e0212fa306b7cfba5057585c5b8470a6141","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070965","Version":"HPG3.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c142554cd76f48fba9ff8f98b1","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.deb","SHA1Sum":"b442b0fd46686a36101aea7693758f008478d25f","SHA256Sum":"3e58b1a58062ecc55b8e25d3618135f28c67615b1b2f8f0c041fe376fba8aaf2","SHA512Sum":"b4ee5a7b3ed468b6e81a4551a1c46612707531ad4ed85e2ba9b2f1e2c0fd35db18e22f9827f5f087772a0a357941bc30850b59b35b9f5461e73a7ebee2db2ae8"}],"ComponentSizeInKB":3574,"CompsigList":["firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/CP072237.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/M52004TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072237.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072237.scexe"],"Name":"firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.deb","SHA1Sum":"b442b0fd46686a36101aea7693758f008478d25f","SHA256Sum":"3e58b1a58062ecc55b8e25d3618135f28c67615b1b2f8f0c041fe376fba8aaf2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0eaa9b97953a460da7fbe706dc","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068634.exe","SHA1Sum":"9518cba68a31f21b2a866d9f26f50625e4f992ad","SHA256Sum":"185b50ee0d312409eeca9994b2412f5f669f7bed8032ecc2a937d9b54c60b51a","SHA512Sum":"680b67937db3b315881426697c4eb4ff8b5f78486d011afb07e9b18622dc17dd0dcfa456defe68a14c8a2b09b93e706df832d2ceead839b0bd03a8e7525dbd18"}],"ComponentSizeInKB":8000,"CompsigList":["cp068634.compsig"],"FileList":["cp068634.xml","cpqsetup.exe","K511HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068634.exe","SHA1Sum":"9518cba68a31f21b2a866d9f26f50625e4f992ad","SHA256Sum":"185b50ee0d312409eeca9994b2412f5f669f7bed8032ecc2a937d9b54c60b51a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3695033488784f1a95f15765ce","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3911.0"}]},"Files":[{"Checksum":[{"Filename":"CP070388.zip","SHA1Sum":"87fab577688884506c5bdb23a6144ec657713eae","SHA256Sum":"72e691861b2607a3e81772d8d61ef5dce5b6b4cfbd755085ab1712c4ea955a57","SHA512Sum":"65ac7c04b0bbf86b7db766a6a8ceebfc9826b9339f5c5c42ebbfbb52d813d4f90d50d2ab684d8403a15bb487f1e1f4a732ba2b7ad4cbce283422d86fae98525f"}],"ComponentSizeInKB":23837,"CompsigList":["CP070388.compsig"],"FileList":["/CP070388_BUILD_4.data","/CP070388.vmexe64","/CP070388.vmfile","/CP070388_VMw.zip","/CP070388.xml","/payload.json","/CP070388_VMw.zip/index.xml","/CP070388_VMw.zip/vendor-index.xml","/CP070388_VMw.zip/metadata.zip","/CP070388_VMw.zip/vib20/CP070388/HPE_bootbank_CP070388_3.30.0.4-8.0.0.20613240.vib","/CP070388_VMw.zip/metadata.zip/vendor-index.xml","/CP070388_VMw.zip/metadata.zip/vmware.xml","/CP070388_VMw.zip/metadata.zip/vibs/CP070388-6263365004378718032.xml","/CP070388_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070388_3.30.0.4-8.0.0.20613240.xml"],"Name":"CP070388.zip","SHA1Sum":"87fab577688884506c5bdb23a6144ec657713eae","SHA256Sum":"72e691861b2607a3e81772d8d61ef5dce5b6b4cfbd755085ab1712c4ea955a57","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"3.30.0","VibList":[{"Name":"CP070388","Version":"3.30.0.4-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d3d9ead363a48a0af804c2d2b","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a575a5651","Version":"HPD3"},{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a575a5652","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","SHA512Sum":"fe3494fa430531ab7f031fe6f71676762dc86f3e98cad49c4e007344a4fd3ce1524eab2f5c230098929efae7e1ae5d5f47f9f54c80cff9f68ae63ceb6b0b4ab7"}],"ComponentSizeInKB":1281,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAeD3.HPb","Toshiba_MG08Air_TAMG08SDAeD3.xml"],"Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWZVQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB008000JWZVR","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6927e5439b7746e3bda2359045","SupportedDevices":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068644.exe","SHA1Sum":"6a3f8647269e8a34502ee7ac5da6d48540934420","SHA256Sum":"ffb18b70bb68d5007cf1774f6b0b6f23d31a2b24903a3b6974f215150b51655f","SHA512Sum":"0ace767d509d77c678674aaf1f534df74089aafb16a062cb6cf67704ecb70463812349d4e422cbdab799d2a853a78f4d6e45d257d50d572fc1ebf02b559a35b2"}],"ComponentSizeInKB":3163,"CompsigList":["cp068644.compsig"],"FileList":["cp068644.xml","cpqsetup.exe","KAPM5ALSHPDB.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068644.exe","SHA1Sum":"6a3f8647269e8a34502ee7ac5da6d48540934420","SHA256Sum":"ffb18b70bb68d5007cf1774f6b0b6f23d31a2b24903a3b6974f215150b51655f","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2ba38c58637a46b988c479eb00","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"MicroserverGen10PlusSPS_05.01.05.103.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.103"}]},"Files":[{"Checksum":[{"Filename":"MicroserverGen10PlusSPS_05.01.05.103.fwpkg","SHA1Sum":"f08918030863b2a715d6cc80440a8f20751c4c7c","SHA256Sum":"2d074d75d531781f5c924a52b85b56f802b197ec3fe30656fce0fbbf2b7a640d","SHA512Sum":"f9d4b277d180971cdfb88c5cab95bb494f211ceb6097ae02e795ac858f1fcabada9e5fd3f87a92143280a62376d088ee23030c26592cfb7deaaeb4b092786820"}],"ComponentSizeInKB":8212,"CompsigList":[],"FileList":["MicroserverGen10PlusSPS_05.01.05.103.signed.bin","MicroserverGen10PlusSPS_05.01.05.103.xml","payload.json"],"Name":"MicroserverGen10PlusSPS_05.01.05.103.fwpkg","SHA1Sum":"f08918030863b2a715d6cc80440a8f20751c4c7c","SHA256Sum":"2d074d75d531781f5c924a52b85b56f802b197ec3fe30656fce0fbbf2b7a640d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.103"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d5cc2651bb61477f84c5a08abe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U48"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8d68452816_0HPD9-2.1_amd64.deb","SHA1Sum":"ea44c071dba54b2d41fff760442e074d45f5f7bb","SHA256Sum":"4286a3a9edcbd4ac21cde76759f2cf3b5384333576231b3ee369eb88b1f7ea89","SHA512Sum":"5fc306db57dcd2c5a1e3b9509a724efaaca1014dfd8dbb7fc223714c3b8381841b384ad63be6e1b3f9f90b2a360470e0f54a140a72696d21408bf2c6aa9c48b4"}],"ComponentSizeInKB":3462,"CompsigList":["firmware-hdd-8d68452816_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/CP071707.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071707.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071707.scexe"],"Name":"firmware-hdd-8d68452816_0HPD9-2.1_amd64.deb","SHA1Sum":"ea44c071dba54b2d41fff760442e074d45f5f7bb","SHA256Sum":"4286a3a9edcbd4ac21cde76759f2cf3b5384333576231b3ee369eb88b1f7ea89","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_29591197caa7452cb1780e6e1f","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f1590032e","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f15900381","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"03.01.47.052"}]},"Files":[{"Checksum":[{"Filename":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.fwpkg","SHA1Sum":"61f9e902e64927e076e41efa09c01550021f370e","SHA256Sum":"6d0d657b5ed2ee88879790fcac7038f99b7b8ec6db709ce8d5782c4042e3cd2b","SHA512Sum":"356a9658dacc87b5fd661a967fac9ab8a567b5db286196194e4b8d391369549f295db0d1e434d9d6f4c829634f46b3a9f9dff1744ba778182ba5c94d82e52f69"}],"ComponentSizeInKB":12186,"CompsigList":[],"FileList":["HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.xml","payload.json"],"Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.fwpkg","SHA1Sum":"61f9e902e64927e076e41efa09c01550021f370e","SHA256Sum":"6d0d657b5ed2ee88879790fcac7038f99b7b8ec6db709ce8d5782c4042e3cd2b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"TypeOfChange":"1","Version":"03.01.47.052"}],"InstallationDependency":{},"Name":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"02DB1590","SWKeyExpectedPath":"firmware"},{"Name":"032E1590","SWKeyExpectedPath":"firmware"},{"Name":"03811590","SWKeyExpectedPath":"firmware"},{"Name":"02941590","SWKeyExpectedPath":"firmware"},{"Name":"02DC1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2ae30555f9543a989b77716df","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U63","U54","U54","U54","U58","A56","A56","A55","A55","I45","U58","U63","U59","U46","U46","A43","A42","A43","U50","A42","U60","U57","U65","U65","U62","A59"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4d094000549756a6b985ee19f5c6e6fcfe19d08a","SHA256Sum":"4532d7a2775a00aa9b195511767983e877663bd4d98ed40997c9f511ba85c3f1","SHA512Sum":"549bd6ea8e72c3c5b9a4097e9204220c44ff84f20de01086579a29eed4defea55713573c358599436198ad37b58acd6d2aaf01ec51bbe76ea3711fe1e5462ce2"}],"ComponentSizeInKB":778,"CompsigList":["elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4d094000549756a6b985ee19f5c6e6fcfe19d08a","SHA256Sum":"4532d7a2775a00aa9b195511767983e877663bd4d98ed40997c9f511ba85c3f1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ff034011bcb44e9bcc183e2e0","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-237.1.137.0-sles15sp6.x86_64.rpm","SHA1Sum":"8db2ed24973937dec5a09a700b565e05e36f26f1","SHA256Sum":"dd35d061ff141b783560f58307a27c30713ad6d9bae99194ab2c56512515549f","SHA512Sum":"b6e6e2a76973835345380eeecc43c843aba551836300b005f0e6ba3d54e5f5b8e87718b1d323d186515db75735d2e97f3b80d8e3f63a09df3d9211ab819c359b"}],"ComponentSizeInKB":54,"CompsigList":["libbnxt_re-237.1.137.0-sles15sp6.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-237.1.137.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-237.1.137.0-sles15sp6.x86_64.rpm","SHA1Sum":"8db2ed24973937dec5a09a700b565e05e36f26f1","SHA256Sum":"dd35d061ff141b783560f58307a27c30713ad6d9bae99194ab2c56512515549f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8a1fc1d5c8d1451b99b47248e1","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U39_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U39_3.66_04_01_2026.fwpkg","SHA1Sum":"854f3ab257d5479a5900b57b400d1e81f2864aef","SHA256Sum":"9c9be99f8758ecae6ced3fdc762032b5e7fc5cb26b3e4f5fbdc066a1b402f61d","SHA512Sum":"8a333fb9c6f4f75bfd2d6460750599f15e6315cf8b35be79d067217b99ac73bf2d10c8dda1ff9a8d3b82f71234b4cba0900b3187ebdd37bd8c5e348024348992"}],"ComponentSizeInKB":32822,"CompsigList":[],"FileList":["payload.json","U39_3.66_04_01_2026.signed.flash","U39_3.66_04_01_2026.xml"],"Name":"U39_3.66_04_01_2026.fwpkg","SHA1Sum":"854f3ab257d5479a5900b57b400d1e81f2864aef","SHA256Sum":"9c9be99f8758ecae6ced3fdc762032b5e7fc5cb26b3e4f5fbdc066a1b402f61d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47c92f4142b44b14b94c614adb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068742.exe","SHA1Sum":"95f34f8d1e44c9ec6ca7410de5b9014020b4a688","SHA256Sum":"21ade002ab63f6d15254406fc07caac6b06cdfac805569a79239b04bd7b454e8","SHA512Sum":"3fac17607321c42f54e6ee4a08564c15154d62f6ebd292ba000951cc6940ee20915e2c3888121fe778ae1a6153a6bc76c6029310293b2f1aa8946bbd226ce080"}],"ComponentSizeInKB":4433,"CompsigList":["cp068742.compsig"],"FileList":["cp068742.xml","cpqsetup.exe","HVLAnAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068742.exe","SHA1Sum":"95f34f8d1e44c9ec6ca7410de5b9014020b4a688","SHA256Sum":"21ade002ab63f6d15254406fc07caac6b06cdfac805569a79239b04bd7b454e8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4df2d8b6de9b405dab609becc2","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8b26d1ef02-HPD2-11.1.x86_64.rpm","SHA1Sum":"a863f245cc83156c5f290a12833bd29bf069c597","SHA256Sum":"5148e77422f8b104d73815c96c0a7c76930ded77cac2774914fc246b64bcb752","SHA512Sum":"afa60cdc9ad3513b73b2caef9a84d5bb48a46b13c070df175dadf81730f15036d45e8667e10fc5f752a3583e4c1d1bc8741cdf73aa438131a0a0c1d1f2bc765b"}],"ComponentSizeInKB":6141,"CompsigList":["firmware-hdd-8b26d1ef02-HPD2-11.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/CP068846.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068846.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068846.scexe"],"Name":"firmware-hdd-8b26d1ef02-HPD2-11.1.x86_64.rpm","SHA1Sum":"a863f245cc83156c5f290a12833bd29bf069c597","SHA256Sum":"5148e77422f8b104d73815c96c0a7c76930ded77cac2774914fc246b64bcb752","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1b5d3a6032d24d3183a0c45f7a","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070546.exe","SHA1Sum":"60064632b37015e220ff46e19d16615223f5f1ba","SHA256Sum":"41a680011ff81fceab30ca572f8d7b335671af364a96dc1b3438c272f625e027","SHA512Sum":"ac0f91b48755b4cab9ad82079565b49534b1f99135e3456d10b542322b440f3bb991fe894463800578ec800ec30d20858ec7f9884eed11eee853316bd93bb6e6"}],"ComponentSizeInKB":1515,"CompsigList":["cp070546.compsig"],"FileList":["cp070546.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070546.exe","SHA1Sum":"60064632b37015e220ff46e19d16615223f5f1ba","SHA256Sum":"41a680011ff81fceab30ca572f8d7b335671af364a96dc1b3438c272f625e027","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"TypeOfChange":"1","Version":"1.24.41.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2afc7a1d9c34cf2aa5139c5f6","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069562.exe","SHA1Sum":"cfe422f523e8126666565d08b4eec0bf12fca554","SHA256Sum":"77d97e35082bd43a7f06e38b6f57b0f0a2b343f58a6f7e09577425d332584895","SHA512Sum":"c889ed512af65793c982f1bd760fad6492744c0db798e182b3ecb5ecbbc5a2bde3fc8b5f9a983d22b69578026a071321fcd4139798fc67ca46e33f5a9a8598e3"}],"ComponentSizeInKB":3381,"CompsigList":["cp069562.compsig"],"FileList":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp069562.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"Name":"cp069562.exe","SHA1Sum":"cfe422f523e8126666565d08b4eec0bf12fca554","SHA256Sum":"77d97e35082bd43a7f06e38b6f57b0f0a2b343f58a6f7e09577425d332584895","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"TypeOfChange":"1","Version":"7.13.221.0"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"evbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4cf57e3d1f7b41a89f2a4e1fbd","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ad103c2231"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U39","J10","U40"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070622.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070626.exe","SHA1Sum":"d6aab718a03ae58500dcd6d55866585b1b6df6b1","SHA256Sum":"5c50ab89830954251a24f2e810cb6804a50b5bb0f1b4ef2316b81509d4931c86","SHA512Sum":"e8f2f296dd1e5b4d28da07155d3410f30029b8b6ebfec589ebf8901f1a3b9ac25cbe9186edbdbe6f1adf1501c46d8d3b43d78304186c0a4865767f434f8a4af3"}],"ComponentSizeInKB":2863,"CompsigList":["cp070626.compsig"],"FileList":["cp070622.compsig","cp070622.zip","cp070626.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070626.exe","SHA1Sum":"d6aab718a03ae58500dcd6d55866585b1b6df6b1","SHA256Sum":"5c50ab89830954251a24f2e810cb6804a50b5bb0f1b4ef2316b81509d4931c86","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a745adf440542eab82166c07b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.deb","SHA1Sum":"7f37fae1bde5db0ab759380e97854e0f52b746fb","SHA256Sum":"06a26327322d19c744fa62bea99f47d52c2573088272934e95cc43115b26155f","SHA512Sum":"c8fcb74693ea3e2f3c3ff4da47800d92a36dfcc53e07cac4fcc287094b30648097f17a18411d8eb5f22db7f4efb61738f578d296ea5c495e8a8a69a12ca432f0"}],"ComponentSizeInKB":4746,"CompsigList":["firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/CP071736.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071736.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071736.scexe"],"Name":"firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.deb","SHA1Sum":"7f37fae1bde5db0ab759380e97854e0f52b746fb","SHA256Sum":"06a26327322d19c744fa62bea99f47d52c2573088272934e95cc43115b26155f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9559ba9ab684ea891b0313d5e","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"netxtreme2-kmp-default-7.15.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"c8c93c32d32a74b31cfb02070a802f97e67574e7","SHA256Sum":"bd193f0ebd1f8b82ab9853c43b8339a0325fd0d03e38a48b4a38c788222195f8","SHA512Sum":"6ad76cd3f612e55a0cbfb37ea6f9840122847c59a4bc1f4280cde4597b907d6eb0d85bba8b5fb09d4585e824fa59bcdea87f2f1e0433dbb09821ef3f77a13fe5"}],"ComponentSizeInKB":8359,"CompsigList":["netxtreme2-kmp-default-7.15.25_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnx2.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2i.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2x.ko","./lib/modules/6.4.0-150600.21-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"c8c93c32d32a74b31cfb02070a802f97e67574e7","SHA256Sum":"bd193f0ebd1f8b82ab9853c43b8339a0325fd0d03e38a48b4a38c788222195f8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.25-10"},{"Checksum":[{"Filename":"netxtreme2-kmp-default-7.15.25_k6.4.0_150700.51-10.sles15sp7.x86_64.rpm","SHA1Sum":"0510156659e493aa7d19f653afda4f6b6c5e5cca","SHA256Sum":"ff1ec5064a7a56bc9dd44df793a3d587aee6248933224ff4d9450afaeb4721fd","SHA512Sum":"d759780fe90f5001f1ee5b23df0af2afe49a9976c08ae7a7a54a3a8d6ef36f6499d4c1be2831a1591f0e4ba5c3943f7af68b058d023f35796e42f9bc96017c13"}],"ComponentSizeInKB":8405,"CompsigList":["netxtreme2-kmp-default-7.15.25_k6.4.0_150700.51-10.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnx2.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2i.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2x.ko","./lib/modules/6.4.0-150700.51-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"Name":"netxtreme2-kmp-default-7.15.25_k6.4.0_150700.51-10.sles15sp7.x86_64.rpm","SHA1Sum":"0510156659e493aa7d19f653afda4f6b6c5e5cca","SHA256Sum":"ff1ec5064a7a56bc9dd44df793a3d587aee6248933224ff4d9450afaeb4721fd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.25-10"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f16a344479db4e1e843bbe26ae","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-305958554a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-305958554a43","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-305958554a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-305958554855","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-305958554856","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-305958554a41","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","SHA1Sum":"9214dd9e0e54a062fd7748d07e1d71b056e47554","SHA256Sum":"5a40fd4dc0a7c09d71013355d6c5ead183b9a9a0d22710e9c8c15f13401d0701","SHA512Sum":"4ded682fe74ec3f52a7130b2f37060d61c36957391a85b35106e37eb7e84fbfbeaf45aaf13f8f772bdc1345117d24d541c8fe5274a3d776fce660daae59a7c77"}],"ComponentSizeInKB":2458,"CompsigList":[],"FileList":["Kioxia_CM7_KACM7ALFHPK4.HPb","Kioxia_CM7_KACM7ALFHPK4.xml","payload.json"],"Name":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","SHA1Sum":"9214dd9e0e54a062fd7748d07e1d71b056e47554","SHA256Sum":"5a40fd4dc0a7c09d71013355d6c5ead183b9a9a0d22710e9c8c15f13401d0701","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600YXUJB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200YXUJC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400YXUJD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920YXUHU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840YXUHV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680YXUJA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_518ac76b543d46469d9245292e","SupportedDevices":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072100.zip","SHA1Sum":"1e87cffce10f0fd6487890d0d401a27136218ce2","SHA256Sum":"01b79e46d6fdd1b7672a049905cbbf6ad80a0c7c2def7fa1c983ecf5777816c5","SHA512Sum":"bd221b0311d5527844a4494a75d27f4c301ac8880d19f855d23582db3f61f3c14765c1cd9b5aea16ee2c337c3df06db126b757582317801c366bee8ba5ba42e1"}],"ComponentSizeInKB":17089,"CompsigList":["cp072100.compsig"],"FileList":["/cp072100.xml","/MIS_bootbank_ssacli2_6.65.9.0-1OEM.800.1.0.20613240.vib","/ssacli2-component_6.65.9.0-0.zip","/ssacli2-component_6.65.9.0-0.zip/index.xml","/ssacli2-component_6.65.9.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip","/ssacli2-component_6.65.9.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.9.0-1OEM.800.1.0.20613240.vib","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vibs/ssacli2-5213612587468599283.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.9.0-0.xml"],"Name":"cp072100.zip","SHA1Sum":"1e87cffce10f0fd6487890d0d401a27136218ce2","SHA256Sum":"01b79e46d6fdd1b7672a049905cbbf6ad80a0c7c2def7fa1c983ecf5777816c5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.9.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.9.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.9.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bbbcfe855d6a4fdaaa14c83925","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"CP072200.zip","SHA1Sum":"77562c6f3854e68f19f6bb3b863edefa883d1f0c","SHA256Sum":"34a05eb7e912901014329086b51810e163875e282e763c8815040de039488c1e","SHA512Sum":"3d29b51b56b5cdc37acd573ec6200d50737350611a227a88d556f1c8e08f6e6764c6994c8b5a41c405878ee42df3c43a6d74d25166bca9dd13a72dd2e9d86830"}],"ComponentSizeInKB":8143,"CompsigList":["CP072200.compsig"],"FileList":["/CP072200_BUILD_1.data","/CP072200.vmcfg","/CP072200.vmexe64","/CP072200.vmfile","/CP072200_VMw.zip","/CP072200.xml","/payload.json","/CP072200_VMw.zip/index.xml","/CP072200_VMw.zip/vendor-index.xml","/CP072200_VMw.zip/metadata.zip","/CP072200_VMw.zip/vib20/CP072200/HPE_bootbank_CP072200_6.00.1-8.0.0.20613240.vib","/CP072200_VMw.zip/metadata.zip/vendor-index.xml","/CP072200_VMw.zip/metadata.zip/vmware.xml","/CP072200_VMw.zip/metadata.zip/vibs/CP072200--195979244729356799.xml","/CP072200_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072200_6.00.1-8.0.0.20613240.xml"],"Name":"CP072200.zip","SHA1Sum":"77562c6f3854e68f19f6bb3b863edefa883d1f0c","SHA256Sum":"34a05eb7e912901014329086b51810e163875e282e763c8815040de039488c1e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00","VibList":[{"Name":"CP072200","Version":"6.00.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0a93984f97a24bb9be208e1bdf","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b58554a54","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58554a55","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58554a56","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58554b41","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b58554a4e","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58554a50","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58554a51","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58554a52","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59475a51","Version":"HPK3"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CD8_KACD8ALSHPK3.fwpkg","SHA1Sum":"2dbfae94556f62477d6cf57a4f50c4697a0f2e36","SHA256Sum":"879e1af39616e1d8a4360d3b776f772800515c3aa89850aa267116baab85475d","SHA512Sum":"c602394bc6732d6b18596884608f429b86673da520b2b68b37f93f9ddc626237622ecd2dc532d397c3155bfba88631f2641a3cb49c220fa588f3bbaeabebccf4"}],"ComponentSizeInKB":2077,"CompsigList":[],"FileList":["Kioxia_CD8_KACD8ALSHPK3.HPb","Kioxia_CD8_KACD8ALSHPK3.xml","payload.json"],"Name":"Kioxia_CD8_KACD8ALSHPK3.fwpkg","SHA1Sum":"2dbfae94556f62477d6cf57a4f50c4697a0f2e36","SHA256Sum":"879e1af39616e1d8a4360d3b776f772800515c3aa89850aa267116baab85475d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"TypeOfChange":"1","Version":"HPK3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MO000800KXUJT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXUJU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXUJV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXUKA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXUJN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXUJP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXUJQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXUJR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYGZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8e76fb6200624a4db4f41115e1","SupportedDevices":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","SHA1Sum":"632a6f9f75c5931ff2c08c4b95d8499f00294996","SHA256Sum":"d55055e32976b6c3eb8b69dd7be1ef612b87771ff92bc58feff5ecd2e11f1e9a","SHA512Sum":"63bc80a83db727ac74fd14ed14befe101aee9462e1296567b483e75c9972f479f32260d9c0cada0d75c487be66c77aac34df281f8c3c8c84966efcf5d793f19a"}],"ComponentSizeInKB":7186,"CompsigList":["firmware-hdd-a27c95663d-HPK6-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/CP068916.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068916.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068916.scexe"],"Name":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","SHA1Sum":"632a6f9f75c5931ff2c08c4b95d8499f00294996","SHA256Sum":"d55055e32976b6c3eb8b69dd7be1ef612b87771ff92bc58feff5ecd2e11f1e9a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_378e98a7adff433fa1102dd3d4","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"CP070908.zip","SHA1Sum":"6f03975dcb89e22f7b9e509db76174e082c58bc8","SHA256Sum":"824af853f15bd1608d3250df708644588dd73de2efb1268ab68b8c5e519ae22d","SHA512Sum":"1732b48d5aa34b2e4318433fe19e59c7b57a65d9c4baf811f846644f96b7800bbb89e4df8d78c5aa2c0e0b30be7a40362c554bb185f33dd1167b3426bb6b9845"}],"ComponentSizeInKB":22717,"CompsigList":["CP070908.compsig"],"FileList":["/CP070908_BUILD_4.data","/CP070908.vmexe64","/CP070908.vmfile","/CP070908_VMw.zip","/CP070908.xml","/payload.json","/CP070908_VMw.zip/index.xml","/CP070908_VMw.zip/vendor-index.xml","/CP070908_VMw.zip/metadata.zip","/CP070908_VMw.zip/vib20/CP070908/HPE_bootbank_CP070908_85032G00.4-8.0.0.20613240.vib","/CP070908_VMw.zip/metadata.zip/vendor-index.xml","/CP070908_VMw.zip/metadata.zip/vmware.xml","/CP070908_VMw.zip/metadata.zip/vibs/CP070908--8879540849907203519.xml","/CP070908_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070908_85032G00.4-8.0.0.20613240.xml"],"Name":"CP070908.zip","SHA1Sum":"6f03975dcb89e22f7b9e509db76174e082c58bc8","SHA256Sum":"824af853f15bd1608d3250df708644588dd73de2efb1268ab68b8c5e519ae22d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00","VibList":[{"Name":"CP070908","Version":"85032G00.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_120d6a8b3ce745a199c5db2d35","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070556.exe","SHA1Sum":"e0b312ee50d3f96bdcd54271ab3536bbbd42c600","SHA256Sum":"28a6491abb3cb0c7d540732d5a56543b849d5f29007daf06fdcb0c3146acde99","SHA512Sum":"78716c27a4b1f0d8c01b05b0b615331d878536163379466174b0a7dea23fd0e2e36adcb9209b0962331a79e6facbf0a9f1e42bc96ea946d67732c4cc13b1a863"}],"ComponentSizeInKB":1218,"CompsigList":["cp070556.compsig"],"FileList":["cp070556.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070556.exe","SHA1Sum":"e0b312ee50d3f96bdcd54271ab3536bbbd42c600","SHA256Sum":"28a6491abb3cb0c7d540732d5a56543b849d5f29007daf06fdcb0c3146acde99","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.24.41.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_92613b1cdf28403094eeb23e93","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_CQDA2_OCP_4p91_NCSIwPLDMoMCTP_800214AD.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_OCP_4p91_NCSIwPLDMoMCTP_800214AD.fwpkg","SHA1Sum":"2a5374c8b341f34f4ea94ee787b41310c7531b74","SHA256Sum":"4a3fce6610ba9170160202fa976cd3a599e78f3914d053eb241f5ea4f7bccb94","SHA512Sum":"b07881606d785755d2d40043462374e4dfbe5522da51ef3389e1cdb052819a3dbef3b8b07095a9a5a1eeaea207a58be28fb6a64a0e2ead0b1fce03d5e2b09703"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_CQDA2_OCP_4p91_NCSIwPLDMoMCTP_800214AD.HPb","HPE_E810_CQDA2_OCP_4p91_NCSIwPLDMoMCTP_800214AD.xml","payload.json"],"Name":"HPE_E810_CQDA2_OCP_4p91_NCSIwPLDMoMCTP_800214AD.fwpkg","SHA1Sum":"2a5374c8b341f34f4ea94ee787b41310c7531b74","SHA256Sum":"4a3fce6610ba9170160202fa976cd3a599e78f3914d053eb241f5ea4f7bccb94","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3dac84cbe13f448aa40cc30f68","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860006"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068751.exe","SHA1Sum":"a65fb6986f02b1e011b5913383dc14d4d0756cea","SHA256Sum":"53ba1ab716f10ca27ae636bb2241d1b2ca7b543eef93f44d54354b96add09501","SHA512Sum":"5641bd3c58669081d3af2e668b54abdc105d62a3cb23beac91a053657b7a3b1922df692a4d5b68efb9a0fcedae16594e9923d4af25610bdcc33d492226735242"}],"ComponentSizeInKB":3905,"CompsigList":["cp068751.compsig"],"FileList":["BCHPC17M.bin","cp068751.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068751.exe","SHA1Sum":"a65fb6986f02b1e011b5913383dc14d4d0756cea","SHA256Sum":"53ba1ab716f10ca27ae636bb2241d1b2ca7b543eef93f44d54354b96add09501","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e5d44479dcd241aa80b77c5e9a","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069520.exe","SHA1Sum":"4d93dd4fe118fa8df2dd309c6a6b575e92d6a797","SHA256Sum":"3bfec1080203d7bb7c5f266e65e32ae60589b541f179289698dfe6ed1ac35724","SHA512Sum":"4e75cca08f0b78a7d96d91112eb312b2c5642f325ab8d64fe1c8cd7561e3c296094715c41298e126989a8170a1c9bde5c9ceae7f74c594fa480880942e89381d"}],"ComponentSizeInKB":1054,"CompsigList":["cp069520.compsig"],"FileList":["cp069520.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069520.exe","SHA1Sum":"4d93dd4fe118fa8df2dd309c6a6b575e92d6a797","SHA256Sum":"3bfec1080203d7bb7c5f266e65e32ae60589b541f179289698dfe6ed1ac35724","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c61d8d675f54d34beb3a14863","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","SHA1Sum":"b0861590d648bbc28cd178db74a87c639a8e661a","SHA256Sum":"6bd5e6a503912a573d4fc2d1aaf337f72a587164765cbdd09f03af8b89a9efba","SHA512Sum":"6720c6c8d1f2ab9505927e9c33a0b44b74492b69a6f23d69e17537c13f7be6263aff17187ce4c17cfac1655da6c239439a55cd469f4a5cd4e55b6afbf9743c0d"}],"ComponentSizeInKB":5751,"CompsigList":["firmware-hdd-18e328f036-HPG8-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/CP068936.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068936.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068936.scexe"],"Name":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","SHA1Sum":"b0861590d648bbc28cd178db74a87c639a8e661a","SHA256Sum":"6bd5e6a503912a573d4fc2d1aaf337f72a587164765cbdd09f03af8b89a9efba","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a2cf298e2444835a79f0b2da8","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-30505a575346","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-30505a575348","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-30505a57534b","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-30505a584641","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM165X_GPM1655SAMD4.fwpkg","SHA1Sum":"c29ac81ebe8e58e92c15654a2ad07d3de9c3690a","SHA256Sum":"583892a4172e615263221d2e5289328774780173b10f3da89b193a8718a71f08","SHA512Sum":"7519551fdf21cd670266d9d7aeaca4b87ab7ad60677aaa735ebf077b7abf4f3abef0661f039b051492257f6414b9de8583528a3f92d8a4bc13ac33d54651ccc1"}],"ComponentSizeInKB":1947,"CompsigList":[],"FileList":["payload.json","Samsung_PM165X_GPM1655SAMD4.HPb","Samsung_PM165X_GPM1655SAMD4.xml"],"Name":"Samsung_PM165X_GPM1655SAMD4.fwpkg","SHA1Sum":"c29ac81ebe8e58e92c15654a2ad07d3de9c3690a","SHA256Sum":"583892a4172e615263221d2e5289328774780173b10f3da89b193a8718a71f08","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3630-3430-30505a584641"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800PZWSF","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001600PZWSH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PZWSK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PZXFA","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c3a30d0c9094371b5e3415413","SupportedDevices":["4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3630-3430-30505a584641"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-492a9952f6_0HPG5-2.1_amd64.deb","SHA1Sum":"8cda1e6655406b77be6b9b0b6a90fbf8b7306e76","SHA256Sum":"a038657a41d17441c8d469999aadfe56460bcc02cd4523b0904ee562797f4480","SHA512Sum":"c43887d6d33e9dbdc218158087cca64fad51106bd729ae350b31cdb8dc4cc49b3f4398479ea5b99256fdb65c5d80e9294507698f82f986638eedebc5f433f785"}],"ComponentSizeInKB":3505,"CompsigList":["firmware-hdd-492a9952f6_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/CP071748.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071748.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071748.scexe"],"Name":"firmware-hdd-492a9952f6_0HPG5-2.1_amd64.deb","SHA1Sum":"8cda1e6655406b77be6b9b0b6a90fbf8b7306e76","SHA256Sum":"a038657a41d17441c8d469999aadfe56460bcc02cd4523b0904ee562797f4480","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_105aea76e7234a4898a01ef7c5","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"cc2ec86a530e0e3fe98669be75ebdfe5f6f58eae","SHA256Sum":"57c41dc5b94a0fae02f5b12ab83006f169e4b73e92421dd4030fe970bf020fb9","SHA512Sum":"79d346e6edbca6b7ebd24a03601621819af662f6aba5cab89f84c72c98c057382977da16eebf0d090334a51c4dacb99f8a16e22537ae59fe86bbc87eeb67003b"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","SC_ML30GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"cc2ec86a530e0e3fe98669be75ebdfe5f6f58eae","SHA256Sum":"57c41dc5b94a0fae02f5b12ab83006f169e4b73e92421dd4030fe970bf020fb9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d819f0ca7314dc0937fdef529","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"cp068633.exe","SHA1Sum":"9db736246b59c83f06d19cf3299613b7f2c9a9df","SHA256Sum":"81d606c783a1d6f4c2438b144fed52cd7f930f4785982d83fedb517cea26cfc7","SHA512Sum":"901e1801e4629a93b264c4c74a9240903b7c9b18b5dee34691d717e3feea2841cd4ccb1317e51840bc048d0522c02d37b939c809827551fef387aedc63b9e8c4"}],"ComponentSizeInKB":7821,"CompsigList":["cp068633.compsig"],"FileList":["cp068633.xml","cpqsetup.exe","mnv_cli.exe","MPK78H5Q.rel","payload.json","setup.dll"],"Name":"cp068633.exe","SHA1Sum":"9db736246b59c83f06d19cf3299613b7f2c9a9df","SHA256Sum":"81d606c783a1d6f4c2438b144fed52cd7f930f4785982d83fedb517cea26cfc7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e41a30bd00ab4b4ba56cdbac8a","SupportedDevices":["4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.3.0-1.rhel10u0.x86_64.rpm","SHA1Sum":"637a76264d5b55dc6761c0d2c785b993c347dddb","SHA256Sum":"f2063f40127f5f26b25ab522c7a7af4ad97f171fe9a5c27f8fd59594d9cfaa1d","SHA512Sum":"c28dfb0d256bb2dcbd2fc8a54446f1e127775b8c0311b94a5e54e370c8a196a67d93f28dc9094e99e6edf4530e5ab8e6742b9d19e42a3b5150bef0541827189c"}],"ComponentSizeInKB":17449,"CompsigList":["kmod-qlgc-fastlinq-8.76.3.0-1.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.3.0-1.rhel10u0.x86_64.rpm","SHA1Sum":"637a76264d5b55dc6761c0d2c785b993c347dddb","SHA256Sum":"f2063f40127f5f26b25ab522c7a7af4ad97f171fe9a5c27f8fd59594d9cfaa1d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.3.0-5"},{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.3.0-5.rhel10u1.x86_64.rpm","SHA1Sum":"ccfe49a716c5c6eb2e91b85428f1a4b3aa544a02","SHA256Sum":"773d1e470b838659fe25fb17c256028a414a87a833675f239aa8db97f19565b6","SHA512Sum":"0700f1c3d20a1d0c584ff86fa02b78dfb0d2990a61c6cdc8e68199e51c46e4e21d053484cff02eb14e23fe2e721107fc998ae9a899e5d395621e3047a5ca8fb2"}],"ComponentSizeInKB":17548,"CompsigList":["kmod-qlgc-fastlinq-8.76.3.0-5.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.3.0-5.rhel10u1.x86_64.rpm","SHA1Sum":"ccfe49a716c5c6eb2e91b85428f1a4b3aa544a02","SHA256Sum":"773d1e470b838659fe25fb17c256028a414a87a833675f239aa8db97f19565b6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.3.0-5"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6e254820553e46efa4743b9010","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.deb","SHA1Sum":"ba1b3f32ac274db5cb443488ed0e3c8d7d7446bf","SHA256Sum":"c54c9f631ec1939414f8fdf3f04628b71c2826dfb35407723bd045f689bdf843","SHA512Sum":"7da6d8cc99b0ed49e273826a90e9ff830de82ab8bf1c9e914d9169755a9cc19d04d458135206897e4df129f15157206f05f7d6cb90b731b8785cec867c154ae0"}],"ComponentSizeInKB":4771,"CompsigList":["firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/CP071772.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071772.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071772.scexe"],"Name":"firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.deb","SHA1Sum":"ba1b3f32ac274db5cb443488ed0e3c8d7d7446bf","SHA256Sum":"c54c9f631ec1939414f8fdf3f04628b71c2826dfb35407723bd045f689bdf843","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_327f159d1a0f46f9a28161a357","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-237.1.137.0-sles16sp0.x86_64.rpm","SHA1Sum":"c07f8fb2a8ba37f6930c7b1313079b8a2a3bea26","SHA256Sum":"cfca07d8b74e45f9312dcb1be73e01ee1733680c36dbd705027df69d7efe7217","SHA512Sum":"63eb6e0bb7fbe7683e87727ccb0eae286d3dcc4b1c3c44a30045967dd38a6dd99b637f696a0a91c7378935085005776cd5bac35afab65e818a09e0ffc19649af"}],"ComponentSizeInKB":265,"CompsigList":["libbnxt_re-237.1.137.0-sles16sp0.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-237.1.137.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-237.1.137.0-sles16sp0.x86_64.rpm","SHA1Sum":"c07f8fb2a8ba37f6930c7b1313079b8a2a3bea26","SHA256Sum":"cfca07d8b74e45f9312dcb1be73e01ee1733680c36dbd705027df69d7efe7217","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 16 SP0","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c48dd4479a54b4e80e5daa99b","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"cp072399.exe","SHA1Sum":"0c5c7945d2ca5eefb6f1808ba07cc0e9723003be","SHA256Sum":"e31a7e7ffb513d4a8c48cff373f0b7446f50db2e7cdc9224456eba73f040011a","SHA512Sum":"d456e192f0530c3e41b65bfa36ceddffc2718376bf76d0636194e60d3bf8526b95f77e9d78a9f5dd38377d84a3ef5d55b57146a90bcc45aeaa9918a75f6a8b95"}],"ComponentSizeInKB":29063,"CompsigList":["cp072399.compsig"],"FileList":["cp072399.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072399.exe","SHA1Sum":"0c5c7945d2ca5eefb6f1808ba07cc0e9723003be","SHA256Sum":"e31a7e7ffb513d4a8c48cff373f0b7446f50db2e7cdc9224456eba73f040011a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.0.19"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2b43009362174268b7b46d88e9","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Files":[{"Checksum":[{"Filename":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","SHA1Sum":"e1ac47651ca19b1bd3094a56f0c368cceba7ad27","SHA256Sum":"32affc2266eac4735a156ca97f3fd3324fd7f42687ca5f43e40035136f406aa0","SHA512Sum":"a9c6cede2d61e0e866ba3d59b002a22e6f9b7cd8aa801c62bc6f770ce678e306e0da62a8e36c24ae00d039ffe46f464445f5c958b44a2590b0f2af4b263237cf"}],"ComponentSizeInKB":9685,"CompsigList":["firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/661SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/CP071036.xml","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/FVL_25G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/XXV710DA2_9p20_CFGID12p0_OEMGEN.bin","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/nvmupdatew64e","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071036.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071036.scexe"],"Name":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","SHA1Sum":"e1ac47651ca19b1bd3094a56f0c368cceba7ad27","SHA256Sum":"32affc2266eac4735a156ca97f3fd3324fd7f42687ca5f43e40035136f406aa0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"InstallationDependency":{},"Name":"HPE Edgeline 661SFP28 NIC Firmware Pack for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a48ea6f356ad447b82d413492a","SupportedDevices":["a6b1a447-382a-5a4f-8086-158b15900253"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","20.4","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068753.exe","SHA1Sum":"c6c1f62b8b5d694d6bdb316c02ae8a370552eabd","SHA256Sum":"a218f3c924a286b8f3aff9bdc3ae0e3c5fd60023d934fb224f10ffc18fe46c68","SHA512Sum":"5045883ca9edcc0ab61d55b5df9a3db122de1f2e432429cb7788b61d339521ec9fae8a28c80c81abf77c54cd4d82018d7a36de95df23a53cc33e8825f29f56f0"}],"ComponentSizeInKB":3552,"CompsigList":["cp068753.compsig"],"FileList":["cp068753.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCPssssASFD4.rel"],"Name":"cp068753.exe","SHA1Sum":"c6c1f62b8b5d694d6bdb316c02ae8a370552eabd","SHA256Sum":"a218f3c924a286b8f3aff9bdc3ae0e3c5fd60023d934fb224f10ffc18fe46c68","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb7c7a062d0d46609b85b13dbd","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072375.zip","SHA1Sum":"e62ca7e096c066edc007b92abc44f7f7a473f677","SHA256Sum":"395dd6eaff19ae079b00d9d43e16231884e41113d6e08e598d3d97151255bca8","SHA512Sum":"5767fe2d545c79e8767508f0e68925288f5664d8a2fc3c11abd037be24e93fd8dd8541264b5c865e5cc6e9d697b86d3818714d673267229617f0f83bf97f8cff"}],"ComponentSizeInKB":28273,"CompsigList":["CP072375.compsig"],"FileList":["/CP072375.xml","/CP072375_VMw.zip","/payload.json","/CP072375.vmexe64","/CP072375.vmfile","/CP072375_VMw.zip/index.xml","/CP072375_VMw.zip/vendor-index.xml","/CP072375_VMw.zip/metadata.zip","/CP072375_VMw.zip/vib20/CP072375/HPE_bootbank_CP072375_1.0.0-8.0.0.21495797.vib","/CP072375_VMw.zip/metadata.zip/vendor-index.xml","/CP072375_VMw.zip/metadata.zip/vmware.xml","/CP072375_VMw.zip/metadata.zip/vibs/CP072375-8912976216253258533.xml","/CP072375_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072375_1.0.0-8.0.0.21495797.xml"],"Name":"CP072375.zip","SHA1Sum":"e62ca7e096c066edc007b92abc44f7f7a473f677","SHA256Sum":"395dd6eaff19ae079b00d9d43e16231884e41113d6e08e598d3d97151255bca8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.8","VibList":[{"Name":"CP072375","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36b15fed590740dc90977b735c","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072403.zip","SHA1Sum":"48aa1e244acc75d02a593e6c53fb0c9d801e2268","SHA256Sum":"34b2e3b4a7d38049a68f0bc0ab72a6b4d6cf26984387adc71c9af5861c26e3b5","SHA512Sum":"c140140917510d1859f3aa56689c81c8d9dc7a0794ba879e32f4eeae9397b1ee8507f54b4bf7377af895a40e0f104a5720f838673fc961e58aa614e4214cb268"}],"ComponentSizeInKB":17947,"CompsigList":["CP072403.compsig"],"FileList":["/CP072403_BUILD_1.data","/CP072403.vmexe64","/CP072403.vmfile","/CP072403_VMw.zip","/CP072403.xml","/payload.json","/CP072403_VMw.zip/index.xml","/CP072403_VMw.zip/vendor-index.xml","/CP072403_VMw.zip/metadata.zip","/CP072403_VMw.zip/vib20/CP072403/HPE_bootbank_CP072403_HPG4.1-8.0.0.20613240.vib","/CP072403_VMw.zip/metadata.zip/vendor-index.xml","/CP072403_VMw.zip/metadata.zip/vmware.xml","/CP072403_VMw.zip/metadata.zip/vibs/CP072403-7040956352853403868.xml","/CP072403_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072403_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072403.zip","SHA1Sum":"48aa1e244acc75d02a593e6c53fb0c9d801e2268","SHA256Sum":"34b2e3b4a7d38049a68f0bc0ab72a6b4d6cf26984387adc71c9af5861c26e3b5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072403","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a87a7480a0714dadb390b9ddab","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","SHA1Sum":"97904324297ff32a46c3311911ef5f51adf557bf","SHA256Sum":"91b70be08d4dac255c32e08898eeba6d33258cbabeda56b92ab2f624d139478d","SHA512Sum":"ab0bdb305af86a8ae6b3e928c57c685f34515767cd398541b976018074e4f1b9d6747ff456b0c61727d9575364b40c9c2ca71ec5a51eb5607298cd9017990aa7"}],"ComponentSizeInKB":5935,"CompsigList":["firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/CP068802.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068802.scexe"],"Name":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","SHA1Sum":"97904324297ff32a46c3311911ef5f51adf557bf","SHA256Sum":"91b70be08d4dac255c32e08898eeba6d33258cbabeda56b92ab2f624d139478d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e3c7f7487e78456cbb96dab819","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071379.exe","SHA1Sum":"1b63099dbf9962d7af2712fd36d0671547b114a0","SHA256Sum":"e60a37e164fa87a74fc4578d1d0137ea8448db74f8a2d9ed5bd7a8811964ed85","SHA512Sum":"01d1fb557c5354b5e61f36427f6c7cbe62ea21fe0ba1e9c52ed0493f3b0d9a87e067ed16cbebe3d0668c5ecf8b700dccff12a711fd178d8f892b4b86cb61e5f3"}],"ComponentSizeInKB":1096,"CompsigList":["cp071379.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.man","bnxtnd.sys","cp071379.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071379.exe","SHA1Sum":"1b63099dbf9962d7af2712fd36d0671547b114a0","SHA256Sum":"e60a37e164fa87a74fc4578d1d0137ea8448db74f8a2d9ed5bd7a8811964ed85","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"237.1.124.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_70f3d4a71764499fa867ac07ee","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U37","U38","U38","O43","U26","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","SHA1Sum":"f042b7b3fd37a879b025b1e286e020ef0e676742","SHA256Sum":"e7fdcc658931d881dbbdd51c23b3d06ec5797d0326377555cc3e5d7416084c99","SHA512Sum":"75fc4e390b30b060943f7055102bbdc4f9b3dc40b7f18a02e9bbd5e036b583ffbf7ceb16983a66f601206eac7414267a842c1e192001376d33f1c683388df839"}],"ComponentSizeInKB":5017,"CompsigList":["firmware-hdd-c993b31232-HPG6-7.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/CP068856.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068856.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068856.scexe"],"Name":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","SHA1Sum":"f042b7b3fd37a879b025b1e286e020ef0e676742","SHA256Sum":"e7fdcc658931d881dbbdd51c23b3d06ec5797d0326377555cc3e5d7416084c99","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b55a0487e34c45578e26e301d0","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070549.exe","SHA1Sum":"9c470fed687c5ae26b6bb0498b216b21b620a7e7","SHA256Sum":"f6141aa034ff597bbfde2aa54c8f6b8066601359900d47ee739ee96e6dd43fb2","SHA512Sum":"3e27d33909493f2774d2c07772bfea987f6abd0816ff76c413309162df66fa33e36e856af5b5363ef9dd4dae8967ae2c75088f34b2539f3179d007d63d9fe888"}],"ComponentSizeInKB":1387,"CompsigList":["cp070549.compsig"],"FileList":["cp070549.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"Name":"cp070549.exe","SHA1Sum":"9c470fed687c5ae26b6bb0498b216b21b620a7e7","SHA256Sum":"f6141aa034ff597bbfde2aa54c8f6b8066601359900d47ee739ee96e6dd43fb2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.18.162.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_78706c05de514f9da46be03235","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","SHA1Sum":"ec8a3f519afbb0cb2d7c0aef6e8ffdce2f89d8d7","SHA256Sum":"ef707a05ac142870ea9e50ba4ec8acb4c6114eb8d1a1b92f84e418178d3df084","SHA512Sum":"f22d1483ede456e787c17535b663924a57673e028886f79d58a86e24836bc30b81c5ab1a565687fe5a2ae8ea4014bc916d7baba65e7ee9faf5674f617972acbe"}],"ComponentSizeInKB":215,"CompsigList":["firmware-powerpic-gen10-1.1.4-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/CP069832.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/PICGen10_v1.1.4_hdr.signed.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069832.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069832.scexe"],"Name":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","SHA1Sum":"ec8a3f519afbb0cb2d7c0aef6e8ffdce2f89d8d7","SHA256Sum":"ef707a05ac142870ea9e50ba4ec8acb4c6114eb8d1a1b92f84e418178d3df084","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_305cf0a5e6cf4fedb2bbda7737","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","12.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A42","A42","A43","A43","A43","A41","A40","U34","U34","U46","U30","U46","U32","U31","U60","U43","U32","U41","U33","U61","U44","U50","U39","U50","U39","U56","U65"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U56_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u56-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"c46b6df1c8c896c7503b8301303f452635cc9bb3","SHA256Sum":"9440ca753a480a1219e9074acebb1afc57e3ac1a345b398eb09f5b9297a03c4e","SHA512Sum":"7004f5ea72fb8797bd6050e2e5cfc1839680ba8397b5fd60bbc6f1a2b0b72c4b1b81b76bfac7aec76d32427837d1c3810cf4727701babf0eb9c6ca2cef945bfa"}],"ComponentSizeInKB":33296,"CompsigList":["firmware-system-u56-2.64_2026_04_01-1.1.x86_64_part1.compsig","firmware-system-u56-2.64_2026_04_01-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/CP071457.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/U56_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071457.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071457.scexe"],"Name":"firmware-system-u56-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"c46b6df1c8c896c7503b8301303f452635cc9bb3","SHA256Sum":"9440ca753a480a1219e9074acebb1afc57e3ac1a345b398eb09f5b9297a03c4e","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_084594eb23c14a488e12882e17","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U56","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE e920 10GbE 2p Network Mezzanine Kit","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101f1590012c","Version":"26.43.1014"}]},"Files":[{"Checksum":[{"Filename":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","SHA1Sum":"d8581abec6fc550febdab1bf76155b31fc682b72","SHA256Sum":"8414e0000cab2de2793f4eb21f363d1466c5967fbd40b95a1695bd7a4b0eda7f","SHA512Sum":"3d244e6ebd06a83a7e1f8ff6440a2ad71b70aa54359dc720c7ad14c61195a932123e996d352f07c259dd164b2557ca2da074db63dd3447613c1249e59ed1fdee"}],"ComponentSizeInKB":6550,"CompsigList":[],"FileList":["26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.xml","payload.json"],"Name":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","SHA1Sum":"d8581abec6fc550febdab1bf76155b31fc682b72","SHA256Sum":"8414e0000cab2de2793f4eb21f363d1466c5967fbd40b95a1695bd7a4b0eda7f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f1590012c"],"TypeOfChange":"1","Version":"26.43.1014"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package (FWPKG) for  HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter :  HPE part number P40899-B21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_E920CX6LX_MEZZ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3ddc1bf7dbbb4a3f823e4a876f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f1590012c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["H10","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070947.zip","SHA1Sum":"63e30c3dfbbdc88574e3122f01877847136f7a79","SHA256Sum":"58c948cc2f712dcc2ea75a7886bd1c780409d1d6828025f7686ffa28a8344ecc","SHA512Sum":"88ce71fe021f245b9cdd9e2f4b3e81a242e63f73b2c9b5c96fe16c16b1f433d978bcfb752df388e2315ea31d5e2ecf98f58eb0ecfaab4db7fa1e64f9a55ba92f"}],"ComponentSizeInKB":17652,"CompsigList":["CP070947.compsig"],"FileList":["/CP070947_BUILD_4.data","/CP070947.vmexe64","/CP070947.vmfile","/CP070947_VMw.zip","/CP070947.xml","/payload.json","/CP070947_VMw.zip/index.xml","/CP070947_VMw.zip/vendor-index.xml","/CP070947_VMw.zip/metadata.zip","/CP070947_VMw.zip/vib20/CP070947/HPE_bootbank_CP070947_HPD6.4-8.0.0.20613240.vib","/CP070947_VMw.zip/metadata.zip/vendor-index.xml","/CP070947_VMw.zip/metadata.zip/vmware.xml","/CP070947_VMw.zip/metadata.zip/vibs/CP070947--6523856759400546116.xml","/CP070947_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070947_HPD6.4-8.0.0.20613240.xml"],"Name":"CP070947.zip","SHA1Sum":"63e30c3dfbbdc88574e3122f01877847136f7a79","SHA256Sum":"58c948cc2f712dcc2ea75a7886bd1c780409d1d6828025f7686ffa28a8344ecc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070947","Version":"HPD6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3afed40b76a47d8ad43c473bf","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H10_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071455.exe","SHA1Sum":"a7746ebcc18a6418d5bc1d24a77fcd31703b2c1f","SHA256Sum":"2329eb4c65c2209b8fddf16b2e559051660349ae8a25d294fff86fd7163324f5","SHA512Sum":"16f1ef06e1ede71c2a5b3b1a5295be17675317c3875d44dbeb136502a9db4b5bfa9211b4c8f624f0c936291ee5cc9c8214676c396c6e89efc37a4499fe5e94b9"}],"ComponentSizeInKB":33435,"CompsigList":["cp071455_part1.compsig","cp071455_part2.compsig"],"FileList":["cp071455.xml","cpqsetup.exe","H10_2.64_04_01_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071455.exe","SHA1Sum":"a7746ebcc18a6418d5bc1d24a77fcd31703b2c1f","SHA256Sum":"2329eb4c65c2209b8fddf16b2e559051660349ae8a25d294fff86fd7163324f5","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7119cae484364543b7790b54bf","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","H10","FTP","H10","H10"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A48_4.04_04_02_2026.fwpkg","SHA1Sum":"36395ed47a36afd8a7efb7f655d1d6ed5596a1c7","SHA256Sum":"0aad28545bbe7dadf732bf045095116b15b23de38428f863ac7e4f34fc08b4da","SHA512Sum":"90cbeb45f32d6871d919b16b8c04ec81459a458d37150c91cc093623f188634e2a71ba34de05f01fca61de8844236a2588687d996252c6609e461b24f60a17db"}],"ComponentSizeInKB":32808,"CompsigList":[],"FileList":["A48_4.04_04_02_2026.signed.flash","A48_4.04_04_02_2026.xml","payload.json"],"Name":"A48_4.04_04_02_2026.fwpkg","SHA1Sum":"36395ed47a36afd8a7efb7f655d1d6ed5596a1c7","SHA256Sum":"0aad28545bbe7dadf732bf045095116b15b23de38428f863ac7e4f34fc08b4da","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_31ecb92b742e40af8dee4d261b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"igb-kmp-default-5.19.10_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"8d077e78b9974a342623bd24be3378a3686173bd","SHA256Sum":"56b830be18397a71fab00079c25c21860ff2a77208b73ba12ead01e941da16ad","SHA512Sum":"74a300eb282b1ca93e59c5b9ddb52c985dfd9b2fb9ecba6c6965efd409f5a6fa07903289f94b762ba1e24c1f9d6265b9ac92cea479e480b2e17565283b55a41b"}],"ComponentSizeInKB":216,"CompsigList":["igb-kmp-default-5.19.10_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/igb.ko","./usr/share/doc/packages/igb-kmp-default","./usr/share/doc/packages/igb-kmp-default/COPYING","./usr/share/doc/packages/igb-kmp-default/README","./usr/share/man/man7/igb.7.gz","./usr/share/pci.ids.d/pci.ids.igb-kmp-5.19.10","./usr/share/smartupdate/igb-kmp-default/component.xml"],"Name":"igb-kmp-default-5.19.10_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"8d077e78b9974a342623bd24be3378a3686173bd","SHA256Sum":"56b830be18397a71fab00079c25c21860ff2a77208b73ba12ead01e941da16ad","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1df98b3d"],"TypeOfChange":"1","Version":"5.19.10-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcecd792d2ab47978094bf035e","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","SHA1Sum":"741ed5eccaa8a8a04b8b81bc05affbc222d63029","SHA256Sum":"eff9d7569abed1473c11bb8b0a5ee80afa685f2228b11178920a18d9e8a7048c","SHA512Sum":"ae0bedf857e87a6bb34c3eb78670687509a42dd6f599177b5bdc23152ab5859835b8c6feaacafa656f7b2f16ebac42804ca4e96704b6053327d171dd7725adab"}],"ComponentSizeInKB":5297,"CompsigList":["firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/CP068826.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068826.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068826.scexe"],"Name":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","SHA1Sum":"741ed5eccaa8a8a04b8b81bc05affbc222d63029","SHA256Sum":"eff9d7569abed1473c11bb8b0a5ee80afa685f2228b11178920a18d9e8a7048c","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00fabe6608db428a9aa80c4965","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Version":"1.2877"},{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-153700000000","Version":"1.2877"}]},"Files":[{"Checksum":[{"Filename":"cp070449.exe","SHA1Sum":"dd9cd0a89f9bcc6df24cd96d8e2fa9236c2823f8","SHA256Sum":"a4448111eb0b78d1efdc2ab6a42c427d02ab396966502ec4b95cd3855fdfe3bb","SHA512Sum":"d2f0283c1212a56c57bf4b3f259b93aba928fd69a4f6d4f8733b6d53a9ee69ebce0bf0a7b09c37502b12eea375f0bd69d5827df2edd4560e8273d27e0ef76fd9"}],"ComponentSizeInKB":9638,"CompsigList":["cp070449.compsig"],"FileList":["BootIMG.FLB","BOOTUTILW64E.EXE","cp070449.xml","cpqsetup.exe","ilorest_chif.dll","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","payload.json"],"Name":"cp070449.exe","SHA1Sum":"dd9cd0a89f9bcc6df24cd96d8e2fa9236c2823f8","SHA256Sum":"a4448111eb0b78d1efdc2ab6a42c427d02ab396966502ec4b95cd3855fdfe3bb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1537FFFF0000","a6b1a447-382a-5a4f-8086-153700000000"],"TypeOfChange":"1","Version":"1.2877"}],"InstallationDependency":{},"Name":"HPE Edgeline i210 NIC Firmware Component for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"i210_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1208eb584aec4cea897af4d3a3","SupportedDevices":["a6b1a447-382a-5a4f-8086-153700000000","a6b1a447-382a-5a4f-8086-1537FFFF0000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","SHA1Sum":"514afdb399cd08ccfc22d428a171ec7f8c61da12","SHA256Sum":"68d0546178be4c47c10bb2c01daf7b4c1b7bf3e190129afc7ebc111a0e3775d0","SHA512Sum":"132ee4a1b9347eb8e8a61f4085e0760fdf93b9ea4f6b68e8b12a46ae6e80ef9a87dc71833649dd2d5a11ec6cd0f174441b4198b466287e64da267d987dc71467"}],"ComponentSizeInKB":8368,"CompsigList":["firmware-iegen10plus-1.0.0.22-9.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/CP069821.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069821.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069821.scexe"],"Name":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","SHA1Sum":"514afdb399cd08ccfc22d428a171ec7f8c61da12","SHA256Sum":"68d0546178be4c47c10bb2c01daf7b4c1b7bf3e190129afc7ebc111a0e3775d0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b751449de7e3448b90a977acbc","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"CP070951.zip","SHA1Sum":"fdc7c6436cc01ff6e22386a739f38f5df17c1197","SHA256Sum":"9cd69dff272fd77cbfaaf4e2f814b1c3cfc7b6d44e255f3803d476e5684e36d4","SHA512Sum":"ac5bf8b06d5ee5627d0686fa89154d2aeec00e6b52c959216acbde895788964038a43809c9115fd2f1792fec8bbf670626aed2c8c700dc1d2db842388f5c5c60"}],"ComponentSizeInKB":19116,"CompsigList":["CP070951.compsig"],"FileList":["/CP070951_BUILD_2.data","/CP070951.vmexe64","/CP070951.vmfile","/CP070951_VMw.zip","/CP070951.xml","/payload.json","/CP070951_VMw.zip/index.xml","/CP070951_VMw.zip/vendor-index.xml","/CP070951_VMw.zip/metadata.zip","/CP070951_VMw.zip/vib20/CP070951/HPE_bootbank_CP070951_HPDC.2-8.0.0.20613240.vib","/CP070951_VMw.zip/metadata.zip/vendor-index.xml","/CP070951_VMw.zip/metadata.zip/vmware.xml","/CP070951_VMw.zip/metadata.zip/vibs/CP070951--7149723854572770878.xml","/CP070951_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070951_HPDC.2-8.0.0.20613240.xml"],"Name":"CP070951.zip","SHA1Sum":"fdc7c6436cc01ff6e22386a739f38f5df17c1197","SHA256Sum":"9cd69dff272fd77cbfaaf4e2f814b1c3cfc7b6d44e255f3803d476e5684e36d4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC","VibList":[{"Name":"CP070951","Version":"HPDC.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_399805b170d2473b88e5eaba95","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-SummitAS-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_SummitAS_SUMMITSUASG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"002340a5-424d-3432-3030-30475945564b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_SummitAS_SUMMITSUASG3.fwpkg","SHA1Sum":"9e50a13bb4f3588e642c951b1fc94ac2574bb28f","SHA256Sum":"736327814937e6586bb8ca1efc10a0f4976fb53cd1d869e3c1217cbbecd0ba12","SHA512Sum":"4b0672a4a5ab6bc011189ed2ea91affe98613b62bec1b8bed1c1f5f451bc51cfc504a79a0831217ea3a918da2fe5e6b8b7a9265e05addec7c12272b95d92bb24"}],"ComponentSizeInKB":3679,"CompsigList":[],"FileList":["payload.json","Seagate_SummitAS_SUMMITSUASG3.HPb","Seagate_SummitAS_SUMMITSUASG3.xml"],"Name":"Seagate_SummitAS_SUMMITSUASG3.fwpkg","SHA1Sum":"9e50a13bb4f3588e642c951b1fc94ac2574bb28f","SHA256Sum":"736327814937e6586bb8ca1efc10a0f4976fb53cd1d869e3c1217cbbecd0ba12","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3432-3030-30475945564b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB24000GYEVK","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB24000GYEVK","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dcecd48f644944afa9df234dfe","SupportedDevices":["002340a5-424d-3432-3030-30475945564b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","SHA1Sum":"8f1571bfeda95b7a465d39e22ca1b98047b22d50","SHA256Sum":"706d9b4aa33867604d31011fc21bacccdec0223524925883b7fd3a56be01fe38","SHA512Sum":"3aa9704ca240cca34dab8513c4db1ebd244c33ffe380caaec7dbea3cb08dff361b7c195bd65a6aadaf11baab12386d09f64e0cb7ff8a4059ad8c56a74d9d3e42"}],"ComponentSizeInKB":7527,"CompsigList":["firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/CP068910.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068910.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068910.scexe"],"Name":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","SHA1Sum":"8f1571bfeda95b7a465d39e22ca1b98047b22d50","SHA256Sum":"706d9b4aa33867604d31011fc21bacccdec0223524925883b7fd3a56be01fe38","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_25502ba383f94660b9ac0d565f","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070544.exe","SHA1Sum":"2746d4cc55c070d1848cb7e9be45d77125efbbe3","SHA256Sum":"a7865426500b097e691e08d923fd3f3f98b7bd410ca01bfbe03a3271bce05a93","SHA512Sum":"4f3ba87c5734bfed369ff3e0e92809bda7e50afdb668404576247509695c4704f67956ec315a707c27136a6a243edd313413ddc17b9ada0bf84fa894d496d965"}],"ComponentSizeInKB":1220,"CompsigList":["cp070544.compsig"],"FileList":["cp070544.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070544.exe","SHA1Sum":"2746d4cc55c070d1848cb7e9be45d77125efbbe3","SHA256Sum":"a7865426500b097e691e08d923fd3f3f98b7bd410ca01bfbe03a3271bce05a93","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.24.42.0"}],"InstallationDependency":{},"Name":"HPE Intel i40ea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9088eede17cc41f0b1b08d6e67","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068655.exe","SHA1Sum":"414eaee2cf6ad92f24df9e62e00e9049c2bdb5ff","SHA256Sum":"3402f61eb05bdfdc21606c18a2d82388f956d0aec7913d45fc35a9da2c9fbf13","SHA512Sum":"f5fd173a5ca3eaf9d35694646b4e921d07c2766dde83c894ff25903c67b08fba454b172e1e3869046f8b6a02f1ee0056a953c1b264edc0ebc83f6d081b537c5b"}],"ComponentSizeInKB":4397,"CompsigList":["cp068655.compsig"],"FileList":["cp068655.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512EDB.rel"],"Name":"cp068655.exe","SHA1Sum":"414eaee2cf6ad92f24df9e62e00e9049c2bdb5ff","SHA256Sum":"3402f61eb05bdfdc21606c18a2d82388f956d0aec7913d45fc35a9da2c9fbf13","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb460e6ce42541ccaa5dad6a16","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ice-2.4.5-1.rhel9u6.x86_64.rpm","SHA1Sum":"ed17639d5c9b66b897e801b6ef71dd1c258f338c","SHA256Sum":"3544d3e6e4f033c77068f5810398e63c3c14a8a5b899eebaeffad6e20f4b06c6","SHA512Sum":"a8094ac02e653d3feb8393ae41c378758d2e48ea65b86dd5731697a7db75a99eb7b08f6da89fb2298238974e26819bc855c835a969759bbf616e3b0992b09ac1"}],"ComponentSizeInKB":1087,"CompsigList":["kmod-ice-2.4.5-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/ice","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/35a56edf0ad33e780b3827a9a52f7596f5b4b6","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.4.5-1.rhel9u6.x86_64.rpm","SHA1Sum":"ed17639d5c9b66b897e801b6ef71dd1c258f338c","SHA256Sum":"3544d3e6e4f033c77068f5810398e63c3c14a8a5b899eebaeffad6e20f4b06c6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.4.5-1"},{"Checksum":[{"Filename":"kmod-ice-2.4.5-1.rhel9u7.x86_64.rpm","SHA1Sum":"2cd48ac06d2e0bb412e9f56f734ac1f33fd2a04a","SHA256Sum":"750c408a7104a2b1f2bf561d95311a3924e569d72be78f935040cd2065e6fb39","SHA512Sum":"d7135bf58c8c25f5d79b098b9950337abd302768083e86a2577e2ef3154fbfa42d110080896a9daacb6374ea844143b0b2c5ba5ed6b9e17c069834fb2d5089a3"}],"ComponentSizeInKB":1142,"CompsigList":["kmod-ice-2.4.5-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.53.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/bf69655c029c6bf5e7f2d322f860efb7900398","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.4.5-1.rhel9u7.x86_64.rpm","SHA1Sum":"2cd48ac06d2e0bb412e9f56f734ac1f33fd2a04a","SHA256Sum":"750c408a7104a2b1f2bf561d95311a3924e569d72be78f935040cd2065e6fb39","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.4.5-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a5c6ab663256481aa8441fa505","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068760.exe","SHA1Sum":"5a4ee195be282872096af18bbed29f8d53eea0a2","SHA256Sum":"d4d7060a9f483f2a3f5950e781ff0ae29d0ee6d01e9175d2ee166b369c3988c5","SHA512Sum":"e5e9f10955d4310ae52f45d3bb1b7d691c41c5aa1641c3d3d61a9a2acf3b1474fe0cf0597c16d089cd05812e52a78ec01c6236ac887291163f474fbda8c719e4"}],"ComponentSizeInKB":3173,"CompsigList":["cp068760.compsig"],"FileList":["cp068760.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXe0HPD9.REL"],"Name":"cp068760.exe","SHA1Sum":"5a4ee195be282872096af18bbed29f8d53eea0a2","SHA256Sum":"d4d7060a9f483f2a3f5950e781ff0ae29d0ee6d01e9175d2ee166b369c3988c5","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6747a7568d794cf59f59ca86ec","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"MRStorageAdministrator-008.016.013.000-00.x86_64.rpm","SHA1Sum":"dfa59d35e5070ef213f740cb871f705c6b2ecc81","SHA256Sum":"758e4c53f8301b95575f45a4ac6a57b244d77a429074076a49f6c8ab0ebc24e1","SHA512Sum":"5462dbc25bd3b28ec6479a85e0aabf279728b211edbc07a4beb88ce3b15bddbbc3bbf9fdca522628f0c46722ef786873bee7c038b807a38d4185119e7348f305"}],"ComponentSizeInKB":31777,"CompsigList":["MRStorageAdministrator-008.016.013.000-00.x86_64.compsig"],"FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/DEF5E163D5F38421F3427280D95CC902.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/72029A9ACB235D6E3F69CAC22955941C.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/D17A5F0B23CB7A6411206417C55D5D20.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/283E1CC6A894D11D96829F24BE4C7845.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F9857EE83F9958DB338B0350DF8758F6.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/F534C8E9E7B61B64EA56530234DDF155.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/0b5e61240eb50f3655a88474f66340b5b6f9df","./usr/lib/.build-id/13","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6.1","./usr/lib/.build-id/16","./usr/lib/.build-id/16/7f3d4cc43253643183b10a90ace2d757c8be44","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/749d5edb6d842cf6ea89cc46d8d5176edadbf1","./usr/lib/.build-id/49","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623.1","./usr/lib/.build-id/66","./usr/lib/.build-id/66/2ab8e9ff03cd2657a7d1f8d16c10350e0fd688","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/0c05383a62bb1e32d30cbe43c9f6bb65bedc5d","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f.1","./usr/lib/.build-id/84","./usr/lib/.build-id/84/bc4a60fa08e959f9cdf5e9d0e14207e79d3dcd","./usr/lib/.build-id/85","./usr/lib/.build-id/85/76426c7c0351fae0fc08447dd86d8d0c9bf71b","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/0bf8294642fe2e0f042e2052f5f72d7f35db53","./usr/lib/.build-id/96","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd.1","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/cb52e946cc50bda2fea6da359438c60f836b6c","./usr/lib/.build-id/a9","./usr/lib/.build-id/a9/178fac2d37acf3ed9077385f1300134deabc2c","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/528fef14473b933716bd893a27602ada8c932c","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/1964206467cfdbf7fa06cf089237bb2f7b78d1","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a.1","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/0dfa30df8f236b986a3dc0036b3576e9a90763","./usr/lib/.build-id/db","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157.1","./usr/lib/.build-id/df","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986.1","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce.1","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3","./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3.1","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"Name":"MRStorageAdministrator-008.016.013.000-00.x86_64.rpm","SHA1Sum":"dfa59d35e5070ef213f740cb871f705c6b2ecc81","SHA256Sum":"758e4c53f8301b95575f45a4ac6a57b244d77a429074076a49f6c8ab0ebc24e1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.16.13.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_68a9e788fdc743ce88bfce8506","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U54","U54","U58","U63","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071368.exe","SHA1Sum":"ec1ae465e69cff296ea3b85a50bde2f6f7ebb116","SHA256Sum":"b3f625c3de82191ec0ac4efc84089663b8263a57899d706151af5e5fe707402a","SHA512Sum":"dc2b68d3ad9b26a7ec95f4718b29b739b1de53e4d71730dbc8e91a0db4c831c7b72d7728a55a297b7651fa0ae2ebde38f942befbde484f6008633a9bf49ebdf5"}],"ComponentSizeInKB":33442,"CompsigList":["cp071368_part1.compsig","cp071368_part2.compsig"],"FileList":["cp071368.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U46_2.64_04_01_2026.signed.flash"],"Name":"cp071368.exe","SHA1Sum":"ec1ae465e69cff296ea3b85a50bde2f6f7ebb116","SHA256Sum":"b3f625c3de82191ec0ac4efc84089663b8263a57899d706151af5e5fe707402a","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc96bc1a1b234ac3a440bc9983","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50PNV2T04","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AFGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AFGA4103"}]},"Files":[{"Checksum":[{"Filename":"cp070412.exe","SHA1Sum":"9bfe38acc9f10b109968e48dc066227b3ae59624","SHA256Sum":"ba48d54cad492cd5ccfa2e95216da56b0d6e74ad7f07e326351919cb4c82c2f2","SHA512Sum":"5739fe46dd42bb651f252fe43ddbbd4b72ed160b5a2af8f318b8a1331fcaeae8ec576aecbe5517b1eed203e5ed45dfa68b3872bf64acc423ea335090d4aff940"}],"ComponentSizeInKB":7468,"CompsigList":["cp070412.compsig"],"FileList":["AFGA4103.sig","cp070412.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"Name":"cp070412.exe","SHA1Sum":"9bfe38acc9f10b109968e48dc066227b3ae59624","SHA256Sum":"ba48d54cad492cd5ccfa2e95216da56b0d6e74ad7f07e326351919cb4c82c2f2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AFGA4103"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50PNV2T04 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"KXG50PNV2T04","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac220d665e8c416882baad1fef","SupportedDevices":["002340a5-584b-3547-3050-4e5632543034"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3d97759111_0HPDB-2.1_amd64.deb","SHA1Sum":"b646f8cdd676047c61f58a07cc2a53830cabd899","SHA256Sum":"77313d55037addd1879aab23f00af053122d999dc3777f5df5000e9e6c4afe00","SHA512Sum":"9caaa537ce76077d2c6ba117ac5ad8748e46e08ceee27e7299622840920b60410642895684c51b006f779ce0788cf495e7d47e42cfc49f5a3dbd64ae9c2e73cf"}],"ComponentSizeInKB":4217,"CompsigList":["firmware-hdd-3d97759111_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/CP071768.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071768.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071768.scexe"],"Name":"firmware-hdd-3d97759111_0HPDB-2.1_amd64.deb","SHA1Sum":"b646f8cdd676047c61f58a07cc2a53830cabd899","SHA256Sum":"77313d55037addd1879aab23f00af053122d999dc3777f5df5000e9e6c4afe00","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8551199339ce49a099213497fc","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.rpm","SHA1Sum":"757323de371566b4c093a2734247c854d0dee949","SHA256Sum":"c5bb29255ec1059664f44d8d14e4756633564bc58708bd701227e26eb8064d2c","SHA512Sum":"234e56b7bb46817da9602092277bf4175f70f7d51a47a3c78fa9d649209431601ef4d2db8e78b47f88fd3acdb8d4da21c49715ffc489e503e8be8c571a606929"}],"ComponentSizeInKB":6170,"CompsigList":["firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/CP072249.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/WLHCCBA0HPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072249.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072249.scexe"],"Name":"firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.rpm","SHA1Sum":"757323de371566b4c093a2734247c854d0dee949","SHA256Sum":"c5bb29255ec1059664f44d8d14e4756633564bc58708bd701227e26eb8064d2c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d6aa1a7ebe547dcbf57ecee73","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","SHA1Sum":"9eb0fae9635cd26524bd9306f3984ee5126580d7","SHA256Sum":"2cd03f3386457becf4703bee44256b4bc67ec6f6c78978ea485729d1c5cfa3bd","SHA512Sum":"5c2ec6da98749c340f3924e6687b9a85630c68657d3bd17bbb93ba691c7882dec28e0d8220fe5970bfd66772c82d16fae620a71b502508ccf019e40380b06138"}],"ComponentSizeInKB":5012,"CompsigList":["firmware-hdd-8d68452816-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/CP068860.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068860.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068860.scexe"],"Name":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","SHA1Sum":"9eb0fae9635cd26524bd9306f3984ee5126580d7","SHA256Sum":"2cd03f3386457becf4703bee44256b4bc67ec6f6c78978ea485729d1c5cfa3bd","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8973e5e1313f4302babcdb7c39","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070926.zip","SHA1Sum":"e5ca82dc1ea061ff5360df32122e8316d54fc2c2","SHA256Sum":"ef51f38d976605891d2612df2b6c3154f22fd428705deabd2d0e48546cb5d5ec","SHA512Sum":"4a56992042c8fdc60ebd2bcc215f5ec0527d98b35499a7f1a370ad65648100f0e37f76b04ec56ba2846abc5c2a325b915944a659290ab860436b8835755192b2"}],"ComponentSizeInKB":17627,"CompsigList":["CP070926.compsig"],"FileList":["/CP070926_BUILD_2.data","/CP070926.vmexe64","/CP070926.vmfile","/CP070926_VMw.zip","/CP070926.xml","/payload.json","/CP070926_VMw.zip/index.xml","/CP070926_VMw.zip/vendor-index.xml","/CP070926_VMw.zip/metadata.zip","/CP070926_VMw.zip/vib20/CP070926/HPE_bootbank_CP070926_HPDB.2-8.0.0.20613240.vib","/CP070926_VMw.zip/metadata.zip/vendor-index.xml","/CP070926_VMw.zip/metadata.zip/vmware.xml","/CP070926_VMw.zip/metadata.zip/vibs/CP070926-5751307503826378903.xml","/CP070926_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070926_HPDB.2-8.0.0.20613240.xml"],"Name":"CP070926.zip","SHA1Sum":"e5ca82dc1ea061ff5360df32122e8316d54fc2c2","SHA256Sum":"ef51f38d976605891d2612df2b6c3154f22fd428705deabd2d0e48546cb5d5ec","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070926","Version":"HPDB.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20ee252f4a0f422bb799cfa92b","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Version":"1.2877"},{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-153700000000","Version":"1.2877"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-i210-nic-1.2877-3.1.x86_64.rpm","SHA1Sum":"611578e2658d6be712cc0eb70af0937c664cae01","SHA256Sum":"0279b6721832ab168edfc917ca4ada7bf99140cc84930dc3a682ca2f2a0c817b","SHA512Sum":"291b8b55a6152ab6084561e611a6af2acceaa51b0dc0b3bcf78a6281d820ca8bc034b8577c0497499bf7b3d458aaf03642ec6e492705ed6646cadfe00b778ddc"}],"ComponentSizeInKB":9127,"CompsigList":["firmware-nic-i210-nic-1.2877-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/CP071035.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/bootutil64e","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071035.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071035.scexe"],"Name":"firmware-nic-i210-nic-1.2877-3.1.x86_64.rpm","SHA1Sum":"611578e2658d6be712cc0eb70af0937c664cae01","SHA256Sum":"0279b6721832ab168edfc917ca4ada7bf99140cc84930dc3a682ca2f2a0c817b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1537FFFF0000","a6b1a447-382a-5a4f-8086-153700000000"],"TypeOfChange":"1","Version":"1.2877"}],"InstallationDependency":{},"Name":"HPE Edgeline i210 NIC Firmware Component for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"i210_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ca69affcbbb4a85a87a5fd02e","SupportedDevices":["a6b1a447-382a-5a4f-8086-153700000000","a6b1a447-382a-5a4f-8086-1537FFFF0000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD665"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SPSGen10_04.01.05.201.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.201"}]},"Files":[{"Checksum":[{"Filename":"SPSGen10_04.01.05.201.fwpkg","SHA1Sum":"9bacff75d60bb49a10f4458ee4ebaf906a4f400a","SHA256Sum":"eda79113a7263eb221897c8b6eaac1ff59d6e776fa9d0cedd0a8d637bcba63c3","SHA512Sum":"11d001d5c2906903813d376c0956b8ba95be03dfcea81a8fd314ae252b9c85bc1b4cf724d729e3ad2d51dc517e8bbfff79bfc946b928655bd9a8595f36fabb2a"}],"ComponentSizeInKB":8217,"CompsigList":[],"FileList":["payload.json","SPSGen10_04.01.05.201.signed.bin","SPSGen10_04.01.05.201.xml"],"Name":"SPSGen10_04.01.05.201.fwpkg","SHA1Sum":"9bacff75d60bb49a10f4458ee4ebaf906a4f400a","SHA256Sum":"eda79113a7263eb221897c8b6eaac1ff59d6e776fa9d0cedd0a8d637bcba63c3","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.201"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_55b6b49088e34c1484eb0eba7e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.deb","SHA1Sum":"3a551b4b6342b0cc2801592b90bf5d3c00f78357","SHA256Sum":"72a4fba14cf7efb9144ec7e90b4ef417166359bbcb3dd0f012b02d6c6595fbfc","SHA512Sum":"163beb91584d29926b8e2ac0a9e518f0f9e2855a8d16fe8d53671938af6a29858282992f58fa7c0f54ea84726f6f67999f739de5abc7e16c508c3fc355d831e2"}],"ComponentSizeInKB":4438,"CompsigList":["firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/CP071735.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071735.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071735.scexe"],"Name":"firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.deb","SHA1Sum":"3a551b4b6342b0cc2801592b90bf5d3c00f78357","SHA256Sum":"72a4fba14cf7efb9144ec7e90b4ef417166359bbcb3dd0f012b02d6c6595fbfc","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c58ad9f5f0084b4ebf812c3995","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069555.exe","SHA1Sum":"24c02f01035020d7f566addc560bcbc1e3d905aa","SHA256Sum":"cf9f66125d626cb6777d05e4779d150fd30d923ce400f590dc084ce4ef833139","SHA512Sum":"e61e022720ad98f8a3b8d488a344fa81c3fce687ded51b36e7b02219e72242ae68b1cfe5f6911b99c27f5033bbaec2e6fbb07029485ce43e57a9450b0b470212"}],"ComponentSizeInKB":833,"CompsigList":["cp069555.compsig"],"FileList":["cp069555.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"Name":"cp069555.exe","SHA1Sum":"24c02f01035020d7f566addc560bcbc1e3d905aa","SHA256Sum":"cf9f66125d626cb6777d05e4779d150fd30d923ce400f590dc084ce4ef833139","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"TypeOfChange":"1","Version":"2.1.252.0"}],"InstallationDependency":{},"Name":"HPE Intel vxn Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"vxn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6d1aec5f11a746129491eab02c","SupportedDevices":["a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-10ed103c211b","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U41","U33","U40","U37","U38","A41","O43","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"MRStorageAdministrator-008.016.013.000-00.rhel10.x86_64.rpm","SHA1Sum":"cca8393d391c41e018782e9f68214ceef366c54a","SHA256Sum":"e98b23903ed1dda4557c382af6c358de1ab1d829a947dccac5d2597f251a59f9","SHA512Sum":"43eba2b462dbf5503a736453a66a0a0acac438c3783b1da922d6467556bf8953ab022642e9fc2af189e6314c2fdcdb05136c09e518dfd6bf66308985dce396d2"}],"ComponentSizeInKB":29036,"CompsigList":["MRStorageAdministrator-008.016.013.000-00.rhel10.x86_64.compsig"],"FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/DEF5E163D5F38421F3427280D95CC902.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/72029A9ACB235D6E3F69CAC22955941C.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/D17A5F0B23CB7A6411206417C55D5D20.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/283E1CC6A894D11D96829F24BE4C7845.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F9857EE83F9958DB338B0350DF8758F6.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/F534C8E9E7B61B64EA56530234DDF155.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671.1","./usr/lib/.build-id/03","./usr/lib/.build-id/03/0a86259236a471e6f766b6e50cc41e27cc0498","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651.1","./usr/lib/.build-id/29","./usr/lib/.build-id/29/888305de5b7482580a0229b344a2384c81ba29","./usr/lib/.build-id/33","./usr/lib/.build-id/33/458cfa214cc81fc145bd5f6907efd7e0aafd1b","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/cc7566a10d2279391763d4de1fe475a37708b9","./usr/lib/.build-id/3e","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379.1","./usr/lib/.build-id/4b","./usr/lib/.build-id/4b/4d9de60cf7d07823954963ea8ff4cf9b91c3e5","./usr/lib/.build-id/69","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9.1","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378.1","./usr/lib/.build-id/78","./usr/lib/.build-id/78/da5729f10b1ae549dcd2f982e13b29c3d113ad","./usr/lib/.build-id/7d","./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60","./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60.1","./usr/lib/.build-id/85","./usr/lib/.build-id/85/76426c7c0351fae0fc08447dd86d8d0c9bf71b","./usr/lib/.build-id/89","./usr/lib/.build-id/89/3e00dea8c28f3251efd84bb7ff04ab33c96425","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42.1","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4.1","./usr/lib/.build-id/cb","./usr/lib/.build-id/cb/e767b04461e1f15de4dcadb9af7a6ff43aab34","./usr/lib/.build-id/cf","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425.1","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/eafadce7028bf03420c1569caeaaf2f36725dc","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/07683d47f51f6563b34d95c705db2e5ac9683d","./usr/lib/.build-id/ff","./usr/lib/.build-id/ff/b9598e564eb735cb5c8e2e603cc86bd533973b","./usr/lib/.build-id/ff/e4ad598a13e45ffccad924a2924c1a47f3fc57","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"Name":"MRStorageAdministrator-008.016.013.000-00.rhel10.x86_64.rpm","SHA1Sum":"cca8393d391c41e018782e9f68214ceef366c54a","SHA256Sum":"e98b23903ed1dda4557c382af6c358de1ab1d829a947dccac5d2597f251a59f9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.16.13.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d9082dc816c54769bf2fbe1cc3","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U54","U54","U58","U63","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"CP070911.zip","SHA1Sum":"295a9eec732210809dcb6eb52ff5cb67ac508234","SHA256Sum":"513c54f89796fc25c597cceb8e36af79e7edeacd36c3175a01313fd314f4b5d9","SHA512Sum":"afbd229641061f9bdb9f2c49f3dfe95864a728d9799724dbc8a9b4386acacf7a290ea1e636a9d6f659d0412a8d19fec24fe7207f2d20fc00675be18f96c0dcb4"}],"ComponentSizeInKB":26910,"CompsigList":["CP070911.compsig"],"FileList":["/CP070911_BUILD_4.data","/CP070911.vmexe64","/CP070911.vmfile","/CP070911_VMw.zip","/CP070911.xml","/payload.json","/CP070911_VMw.zip/index.xml","/CP070911_VMw.zip/vendor-index.xml","/CP070911_VMw.zip/metadata.zip","/CP070911_VMw.zip/vib20/CP070911/HPE_bootbank_CP070911_MPK78H5Q.4-8.0.0.20613240.vib","/CP070911_VMw.zip/metadata.zip/vendor-index.xml","/CP070911_VMw.zip/metadata.zip/vmware.xml","/CP070911_VMw.zip/metadata.zip/vibs/CP070911--141142834386941589.xml","/CP070911_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070911_MPK78H5Q.4-8.0.0.20613240.xml"],"Name":"CP070911.zip","SHA1Sum":"295a9eec732210809dcb6eb52ff5cb67ac508234","SHA256Sum":"513c54f89796fc25c597cceb8e36af79e7edeacd36c3175a01313fd314f4b5d9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"TypeOfChange":"1","Version":"MPK78H5Q","VibList":[{"Name":"CP070911","Version":"MPK78H5Q.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_99e61b9a2e584586a3104d791d","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3936-304894dc03d2"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071214.exe","SHA1Sum":"3085b3ffc2de5e03ab2fd8d0f68ce5395505310f","SHA256Sum":"d03f91276b40cb2d8566f3709869f7d31069e028afa1448846009ce144cf6ed2","SHA512Sum":"201f5a272fd7cb44b966868ba9787fe21d235d6da5373506f9732f15933e8639c9f19a886a4ac0ad03d7ce71301c27cd111f41c9e44dadcdabe561ed9c213b48"}],"ComponentSizeInKB":4210,"CompsigList":["cp071214.compsig"],"FileList":["cp071214.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp071214.exe","SHA1Sum":"3085b3ffc2de5e03ab2fd8d0f68ce5395505310f","SHA256Sum":"d03f91276b40cb2d8566f3709869f7d31069e028afa1448846009ce144cf6ed2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.0"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ade8aa407a294fdfa0a7aa3e05","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.rpm","SHA1Sum":"e5217617de418af3c81e11a6b5e1a4d6545bb449","SHA256Sum":"dc98068ea22feb240e4e71ceaa110411bbe76fce5483b38ba4390fcf9f9af2a7","SHA512Sum":"b6d820687b9e68f8b4f708a1b4410fe81b602f1df00a1aed7dbd7810a508b7e88bf71a129d86180721f8ee159c764882ae9a40c9bf7d0e0ab2f9e8e8f920f4f8"}],"ComponentSizeInKB":805,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.rpm","SHA1Sum":"e5217617de418af3c81e11a6b5e1a4d6545bb449","SHA256Sum":"dc98068ea22feb240e4e71ceaa110411bbe76fce5483b38ba4390fcf9f9af2a7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Server Update 8 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0f94a53064be4a13acc85b7401","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"CP072108.zip","SHA1Sum":"c725823b2fd4dfee784bad6f7005e32ab86574cc","SHA256Sum":"8eabb4e5e7af2f01e197fabe413469e81a07bb05c1badd173827619f73fac0aa","SHA512Sum":"fbb8570d0dbdd4859391b9a59961a669e077ae089af6e1eeb4bd5dafafb31473595bf15f2618710a5c6183d1be65316ff8e655b9142cda598f423d7332ea5e24"}],"ComponentSizeInKB":6735,"CompsigList":["CP072108.compsig"],"FileList":["/CP072108_BUILD_1.data","/CP072108.vmexe","/CP072108.vmexe64","/CP072108.vmfile","/CP072108_VMw.zip","/CP072108.xml","/payload.json","/CP072108_VMw.zip/index.xml","/CP072108_VMw.zip/vendor-index.xml","/CP072108_VMw.zip/metadata.zip","/CP072108_VMw.zip/vib20/CP072108/HPE_bootbank_CP072108_CP072108.1-1OEM.900.0.24755229.vib","/CP072108_VMw.zip/metadata.zip/vendor-index.xml","/CP072108_VMw.zip/metadata.zip/vmware.xml","/CP072108_VMw.zip/metadata.zip/vibs/CP072108-7189677174352235414.xml","/CP072108_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072108_CP072108.1-1OEM.900.0.24755229.xml"],"Name":"CP072108.zip","SHA1Sum":"c725823b2fd4dfee784bad6f7005e32ab86574cc","SHA256Sum":"8eabb4e5e7af2f01e197fabe413469e81a07bb05c1badd173827619f73fac0aa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02","VibList":[{"Name":"CP072108","Version":"CP072108.1-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 9.0 and vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0d29858b67b842d2be05d144c5","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.rpm","SHA1Sum":"3e2aa09c4314f9ce7635fe9ecd4c43ca098233bd","SHA256Sum":"89a14560da4c211c0a8e41477edfca72d3771f958952ed651dbc8053911bd293","SHA512Sum":"c54dfe6a30d2a6a8efffd5b8f115ddee95dec84d6f01c87886cb3e7d47a085f5c6a019d2f64d2bad96973227a8c2bcdd5edd580187ce098d944a944f3aafa20c"}],"ComponentSizeInKB":5716,"CompsigList":["firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/CP068771.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/TAMG08acHPG5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068771.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068771.scexe"],"Name":"firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.rpm","SHA1Sum":"3e2aa09c4314f9ce7635fe9ecd4c43ca098233bd","SHA256Sum":"89a14560da4c211c0a8e41477edfca72d3771f958952ed651dbc8053911bd293","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6e6d29bd80284557a538b51f01","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.64 (04/01/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U46_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u46-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"fa519cb0ab0c747a9c3ff8794e2d3b90b9c8b149","SHA256Sum":"bbf4dbd3d7726ac908d9584366dd0c5163a93b4d0e250b9bfe74d9eee603e1f0","SHA512Sum":"11b4de28a527b3d20fd66e8048f3b6c38f7ec4232546cfe113160a6e257d2c8b2131317fd515913123640d62c8ce22df408a65004c02e584570cd70feac5df3e"}],"ComponentSizeInKB":33287,"CompsigList":["firmware-system-u46-2.64_2026_04_01-1.1.x86_64_part1.compsig","firmware-system-u46-2.64_2026_04_01-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/CP071370.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/U46_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071370.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071370.scexe"],"Name":"firmware-system-u46-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"fa519cb0ab0c747a9c3ff8794e2d3b90b9c8b149","SHA256Sum":"bbf4dbd3d7726ac908d9584366dd0c5163a93b4d0e250b9bfe74d9eee603e1f0","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2d0eabf944149599dab55598b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070019.zip","SHA1Sum":"83a39a47c7c3467bd16cf53addf0860ea05d772b","SHA256Sum":"d426d861c24500204e130f618f3ad4b67f9ecd8ba8442e2ae64a690907053bf8","SHA512Sum":"1f74f9f7e4c7b1bc80133d3e2983f230c73c76e06c17fa206f6f1ef07ee5030ff6aef8b9dc737cfc480a07179f58036e97704326be54dce61b1396f50f8b249f"}],"ComponentSizeInKB":21,"CompsigList":["cp070019.compsig"],"FileList":["/cp070019.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vib20/ilo/HPE_bootbank_ilo_800.10.9.1.4-1OEM.800.1.0.20613240.vib","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ilo--1061765975396018296.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.xml"],"Name":"cp070019.zip","SHA1Sum":"83a39a47c7c3467bd16cf53addf0860ea05d772b","SHA256Sum":"d426d861c24500204e130f618f3ad4b67f9ecd8ba8442e2ae64a690907053bf8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"ilo","Version":"800.10.9.1.4-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ilo-driver:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ilo:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_be8b2b439bf74624967d809ec0","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U41","U33","U37","U38","U38","U40","A41","U43","U44","A42","A43","U31","U31","A46","U48","U39","U46","A42","U46","A43","A43","A42","U47","U47","I44","I43","I42","U61","U60","A48","A47","U45","U50","U54","U54","U54","U58","U58","U59","U46","A56","A56","A55","A55","U56","U64","U65","U62","U63","U58","U63","I45","U57","U65","U65","A58","H11"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","SHA1Sum":"2d9ed8425fecf3dbedf1830b11bd5c90d8e3dafa","SHA256Sum":"fab19de9378e1abc091abef651330298e984a6f6684a8c36167fd680ebdacf97","SHA512Sum":"467e70a9d37db0c1fb0b8ef0f578d0558b4cdd84141435db7208255e09a3b42ff20bca03b93efc5fb937fecf6f1d6b619092571859c0e273e2f27c96b3cbfa29"}],"ComponentSizeInKB":5878,"CompsigList":["firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/CP068929.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068929.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068929.scexe"],"Name":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","SHA1Sum":"2d9ed8425fecf3dbedf1830b11bd5c90d8e3dafa","SHA256Sum":"fab19de9378e1abc091abef651330298e984a6f6684a8c36167fd680ebdacf97","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d0081a2928643a98e1eabd433","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304b59445054","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304b59445055","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304b59445056","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304b59445141","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","SHA1Sum":"f7b2a4cdf23cca06910d78b2ebfc23a2ac5a8605","SHA256Sum":"08e9d14dd7cae0b3670db0bc83ba12f3fd2f40a407f363283e58e28ec672518a","SHA512Sum":"69af49cee07d4c393e44f47cc135db5f25c25688a2737b9011836e2cdd791b47a1bcc0a07b829abd74e2cf5eda7699d8bc4db1f5d8f2e43aced6f6a5392dcc0d"}],"ComponentSizeInKB":3095,"CompsigList":[],"FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK6.HPb","Samsung_PM9A3_GPM9A3SAHPK6.xml"],"Name":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","SHA1Sum":"f7b2a4cdf23cca06910d78b2ebfc23a2ac5a8605","SHA256Sum":"08e9d14dd7cae0b3670db0bc83ba12f3fd2f40a407f363283e58e28ec672518a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000960KYDPT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK001920KYDPU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK003840KYDPV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK007680KYDQA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46c24384109040aea7a6064e47","SupportedDevices":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","SHA1Sum":"0780dd7bd4216ae12774d98d540f9e63e2c868d2","SHA256Sum":"5e601cfa863906f9685ef674999da38fda075053284c6743534631d9efb7af4d","SHA512Sum":"be0475987d7a38f6ab4abb732217f8ca04307d3f20ef252ae86898a12012363bc44711c30e13b7e9e77498f5ef37a858c5574696cb25e299195bf97db3ddfc5d"}],"ComponentSizeInKB":6634,"CompsigList":["firmware-hdd-abd133f0de-HPG1-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/CP068918.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/HPG1_PM893.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068918.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068918.scexe"],"Name":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","SHA1Sum":"0780dd7bd4216ae12774d98d540f9e63e2c868d2","SHA256Sum":"5e601cfa863906f9685ef674999da38fda075053284c6743534631d9efb7af4d","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bdb052e5bc314474ac40768eeb","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"firmware-disk-enclosure_5.04-3.1_amd64.deb","SHA1Sum":"c2ac01024606e093198a2106410af9f8d856bfa2","SHA256Sum":"85f168b1f0223157765c8fb61a7e6999a580f7016bc32d71ac90c273d74324cf","SHA512Sum":"1cb794ca736e56381592cc70063c524d1189cab5252fefc4585a2ffcf89e9eabd9516fccc19a981cd067a7fb2b10dcad362f61e1503d20af84f88b1eb6b0a6ac"}],"ComponentSizeInKB":2316,"CompsigList":["firmware-disk-enclosure_5.04-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/CP072184.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072184.scexe","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072184.scexe"],"Name":"firmware-disk-enclosure_5.04-3.1_amd64.deb","SHA1Sum":"c2ac01024606e093198a2106410af9f8d856bfa2","SHA256Sum":"85f168b1f0223157765c8fb61a7e6999a580f7016bc32d71ac90c273d74324cf","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c46a5509aa964cf08d9a9fe3e3","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-ixgbevf-5.2.2-1.rhel9u6.x86_64.rpm","SHA1Sum":"a83843faf83c63e0c4e0b2f57f184af700fd3ddf","SHA256Sum":"6cb6f20d0ea4cd483b4dbf29c74a56fea8024ac9515cdcae0a472a10e11e6b75","SHA512Sum":"e8c08d90d7108cbe4cdd18712192d1513a52bc93091eb1f549904ced05be0fb3d4b95396e82b4ee58302151aa939e1642c54e3de045c5fd8ca4c5fdae7e07f60"}],"ComponentSizeInKB":79,"CompsigList":["kmod-hp-ixgbevf-5.2.2-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/07bc2ab14df1fdf7c0cb7bfec9d5f2ef3bf0ce","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"Name":"kmod-hp-ixgbevf-5.2.2-1.rhel9u6.x86_64.rpm","SHA1Sum":"a83843faf83c63e0c4e0b2f57f184af700fd3ddf","SHA256Sum":"6cb6f20d0ea4cd483b4dbf29c74a56fea8024ac9515cdcae0a472a10e11e6b75","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.2.2-1"},{"Checksum":[{"Filename":"kmod-hp-ixgbevf-5.2.2-1.rhel9u7.x86_64.rpm","SHA1Sum":"4046e9a35a222afddfd8b7b4cdcbdafbb73e3a31","SHA256Sum":"3d6dfb9e1762a685d0932df2406994eb5aeb231ce0aa88c3ce1d4229dfaaf155","SHA512Sum":"d1ed5129a28ca07cafe766188cb85e61bcf6c323edcfb63c57bdb9f96f82155fe02a6d46d1793379c18144e31d5c9a2dd85bcb3c8569437e66ed250889c76ac3"}],"ComponentSizeInKB":80,"CompsigList":["kmod-hp-ixgbevf-5.2.2-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/98","./usr/lib/.build-id/98/fbb6ed465e9ada3c03d6d1f7a3e0649bc65a4b","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"Name":"kmod-hp-ixgbevf-5.2.2-1.rhel9u7.x86_64.rpm","SHA1Sum":"4046e9a35a222afddfd8b7b4cdcbdafbb73e3a31","SHA256Sum":"3d6dfb9e1762a685d0932df2406994eb5aeb231ce0aa88c3ce1d4229dfaaf155","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.2.2-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_82ef6e94843345229b78d9dd41","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957504-N425H.fwpkg","SHA1Sum":"a80b5d5e63864f3c65d3999d04808a1d92e9054d","SHA256Sum":"9f01b9498831827b0a799753b2ade0ef9a79ec57764df2e0927e3e03e1bb4122","SHA512Sum":"edccd5186448fbb83c5b4f8f559f12236dcad4c6841615e6fa5d08143907b494a5f02f92be2c588a2437fdc0fe52e25de4431d19930021f30e5b3e1bfd05752e"}],"ComponentSizeInKB":2870,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957504-N425H.HPb","BCM237.1.148.0_BCM957504-N425H.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957504-N425H.fwpkg","SHA1Sum":"a80b5d5e63864f3c65d3999d04808a1d92e9054d","SHA256Sum":"9f01b9498831827b0a799753b2ade0ef9a79ec57764df2e0927e3e03e1bb4122","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57504OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a4c027bee9b247e8bc2f8af425","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"26_49_1014-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.49.1014"}]},"Files":[{"Checksum":[{"Filename":"26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"e3515f64abf034937be1b603ff075f4685a523a1","SHA256Sum":"eaf8509c09f69b109a36d3a8640fa0bdaef877ffaaead77649ae7459129c5996","SHA512Sum":"e10183fc07e82cbf820756e1b9c18872788ae4fb0839abddf6b27b1f86a7bed6d3a2cbc2a2013a88ab5fa5c9f6183f41f595d6b850d46aa7b5f00f7622e549c2"}],"ComponentSizeInKB":7171,"CompsigList":[],"FileList":["26_49_1014-MCX631432AS-ADA_Ax.pldm.signed","26_49_1014-MCX631432AS-ADA_Ax.pldm.xml","payload.json"],"Name":"26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"e3515f64abf034937be1b603ff075f4685a523a1","SHA256Sum":"eaf8509c09f69b109a36d3a8640fa0bdaef877ffaaead77649ae7459129c5996","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"TypeOfChange":"1","Version":"26.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631432AS-ADAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b58cb3fe2ca48a78f61d076d4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U63","U65","U68","U68","U68","U66","A66","A66","U72","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070565.exe","SHA1Sum":"936a366abeeb954a748caec075c4786581b11907","SHA256Sum":"c6a57d0640561c8df1aa58fa3487183fa46c84848552e9269cd13ff4acffa1d0","SHA512Sum":"452e949c5764918db5cb376c67774dbf1f3654b36c82dd4f04abd87ee48d9d2dfcb5735e91403fa60f8161509a7f265026352cc35658728002f64b9d8ab330f0"}],"ComponentSizeInKB":835,"CompsigList":["cp070565.compsig"],"FileList":["cp070565.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"Name":"cp070565.exe","SHA1Sum":"936a366abeeb954a748caec075c4786581b11907","SHA256Sum":"c6a57d0640561c8df1aa58fa3487183fa46c84848552e9269cd13ff4acffa1d0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.7.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_78f8d72267e84dd0a155067114","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"cp068652.exe","SHA1Sum":"0b25b6cf45cc22f587cb896d91381525e9c5ed7b","SHA256Sum":"3c26def9c3523a9eb1d796282173658dc5d1347022a56603e0690ef56e272277","SHA512Sum":"f0d70a32c50e41e20f02218874b43375601bac991b5f3c005c59e23b43612517f8635c14809a6e43b4cde39ea259f54738282e00c94c9b82161a0e5a9a95e0d3"}],"ComponentSizeInKB":4581,"CompsigList":["cp068652.compsig"],"FileList":["cp068652.xml","cpqsetup.exe","KACM6ALFGPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068652.exe","SHA1Sum":"0b25b6cf45cc22f587cb896d91381525e9c5ed7b","SHA256Sum":"3c26def9c3523a9eb1d796282173658dc5d1347022a56603e0690ef56e272277","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_830635266472425cad538063c1","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SPSGen10Plus_04.04.04.925.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.925"}]},"Files":[{"Checksum":[{"Filename":"SPSGen10Plus_04.04.04.925.fwpkg","SHA1Sum":"0eb82abce22bd065d795b88d9573646851ac2662","SHA256Sum":"3bf5bf79de030fd4537188fc39af252f0f19448bf001dae4d3c3edf6dfaa759b","SHA512Sum":"e7dc67d432eb65cd1a22705dcd5b83a28496dc7a036f81c5663c52ef283ccbf4b94135cdce99cefc38c18f50d54a4f669a1bcdf124c92676a9cd4564440a43fb"}],"ComponentSizeInKB":8214,"CompsigList":[],"FileList":["payload.json","SPSGen10Plus_04.04.04.925.signed.bin","SPSGen10Plus_04.04.04.925.xml"],"Name":"SPSGen10Plus_04.04.04.925.fwpkg","SHA1Sum":"0eb82abce22bd065d795b88d9573646851ac2662","SHA256Sum":"3bf5bf79de030fd4537188fc39af252f0f19448bf001dae4d3c3edf6dfaa759b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.925"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f918a09809e948138d50a11ebd","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10","U36","U46"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"22_49_1014-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.49.1014"}]},"Files":[{"Checksum":[{"Filename":"22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg","SHA1Sum":"97fac18b6ab97ffe37ecfd00f50ce34c585f9602","SHA256Sum":"9d9f0b87bad0622bf12b0d7c984625750a271df09f0c9ee18e7a7b12bdd70f48","SHA512Sum":"6ab4bafb182c5bf2770ac022a31f20c59133435a993afaebeec43c8eb865909b49916a0da60b26808e4d822c68ad42dd8066b83e3e9d080569091bdc855c8354"}],"ComponentSizeInKB":7729,"CompsigList":[],"FileList":["22_49_1014-MCX623106AS-CDA_Ax.pldm.signed","22_49_1014-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"Name":"22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg","SHA1Sum":"97fac18b6ab97ffe37ecfd00f50ce34c585f9602","SHA256Sum":"9d9f0b87bad0622bf12b0d7c984625750a271df09f0c9ee18e7a7b12bdd70f48","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"TypeOfChange":"1","Version":"22.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3a70a6a1c8341b9a5502aa349","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U58","U58","H10","H10","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U68","U68","U66","A59","A66","A66","U72","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072134.exe","SHA1Sum":"e96c2317c1c11cfd344140eac3bad04937ebbe6e","SHA256Sum":"86acc823cc3cca15dbc1eb2f1835e508989a819e43cea8fdeb2611ebf9d7238c","SHA512Sum":"1aa0ecfb409782995b0f598f3ea96ab172d8c94a278914611106645b1ea89504f72e1ab40721b2f7d5a7d9f8b0d42420ac2587948c487b311ef6471fb0917a58"}],"ComponentSizeInKB":3307,"CompsigList":["cp072134.compsig"],"FileList":["cp072134.xml","cpqsetup.exe","M52004TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072134.exe","SHA1Sum":"e96c2317c1c11cfd344140eac3bad04937ebbe6e","SHA256Sum":"86acc823cc3cca15dbc1eb2f1835e508989a819e43cea8fdeb2611ebf9d7238c","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f573ab37db44c01ba67b0c544","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.deb","SHA1Sum":"987dc84773633e6a8198993e90efbb239ad98440","SHA256Sum":"321a8842b1f285a5463840787f5fbc0d4da973628d1aae659cb61d70de6540f6","SHA512Sum":"a7dafc34a5c540c4d2e3300cfe2b6a483f0b6165c06abdcd168719b8cf96cd585fb6153bd55da3cb24f28497315d890d7329d6842189b749d117b92eba05bb71"}],"ComponentSizeInKB":4657,"CompsigList":["firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/CP071766.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071766.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071766.scexe"],"Name":"firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.deb","SHA1Sum":"987dc84773633e6a8198993e90efbb239ad98440","SHA256Sum":"321a8842b1f285a5463840787f5fbc0d4da973628d1aae659cb61d70de6540f6","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9cb13839f7f44dbf9998bbb2eb","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"237.1.148000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"237.1.148000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"237.1.148000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"237.1.148000"}]},"Files":[{"Checksum":[{"Filename":"cp071469.exe","SHA1Sum":"843d3551127781c20da2938a5c9ec2e210112c9f","SHA256Sum":"43462b46a2cd1e6b2d6c1bbdcdcc8a725f5cd31bd7bcc2cf389769955f326394","SHA512Sum":"6d3de31617e0180dce1a99c1afc2a882733b3d7bd88eb10a2d49efdd0a6fcd6df63261e5b9d89f9195e154b341c7c0a1f7febdb52c906aee2172eb6cd2664d1b"}],"ComponentSizeInKB":10195,"CompsigList":["cp071469.compsig"],"FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp071469.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp071469.exe","SHA1Sum":"843d3551127781c20da2938a5c9ec2e210112c9f","SHA256Sum":"43462b46a2cd1e6b2d6c1bbdcdcc8a725f5cd31bd7bcc2cf389769955f326394","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.4.7.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1ddb272f8f224633ae8fea18ff","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068752.exe","SHA1Sum":"1f73738859667975bc361cfdb46e0aac4153153a","SHA256Sum":"f0fce030a655ee17f8d2365ad447e6394b0e746a1738d39e3afba5577d3dc2c3","SHA512Sum":"b62cb1f98076016571c958e4448a37a8a77a8f4d8c8dfeb4e20e303a812906f402471b266b562ddeb02b0441c6f0c31e2062ed4dee8f41a0b82f05bc95a4c445"}],"ComponentSizeInKB":3578,"CompsigList":["cp068752.compsig"],"FileList":["cp068752.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCQssssASFD2.rel"],"Name":"cp068752.exe","SHA1Sum":"1f73738859667975bc361cfdb46e0aac4153153a","SHA256Sum":"f0fce030a655ee17f8d2365ad447e6394b0e746a1738d39e3afba5577d3dc2c3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_658a48b6cc0742208d5882f3f0","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e","4d2340a5-304f-3531-3336-304a58424656","4d2340a5-304f-3730-3638-304a58424741"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3911.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-intel-1.37.0-1.1.x86_64.rpm","SHA1Sum":"c3a0e40f661468e4ea61ba1423c53b5199669435","SHA256Sum":"82c9aebfbd933341c54111e9ee7ee87ef8c3080c2c723ff2b0166305860c0cc9","SHA512Sum":"e53cc02e3a59de51ba9ec1e27d3262ae2dd123b8a0c18d62f723434fd0188837c0f397fc530665aabd5d4db7fbd7ecb599718038d12d0d1424c1b675cbe74929"}],"ComponentSizeInKB":10167,"CompsigList":["firmware-nic-intel-1.37.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/CP070387.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/CP070387.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.37.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070387.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070387.scexe"],"Name":"firmware-nic-intel-1.37.0-1.1.x86_64.rpm","SHA1Sum":"c3a0e40f661468e4ea61ba1423c53b5199669435","SHA256Sum":"82c9aebfbd933341c54111e9ee7ee87ef8c3080c2c723ff2b0166305860c0cc9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"1.37.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1df98b3d","SWKey":"igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecdb806fec","SWKey":"i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36","SWKey":"hp-ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb870faaa","SWKey":"ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccba99d79","SWKey":"kmod-hp-ixgbe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:intel_nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_97f7727075ec4543a36414468c","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp072239.exe","SHA1Sum":"2ab6fc9ca9652ad6a1b9328bc4d86629e61518d6","SHA256Sum":"7669c6465ab253de78752bee6987050ed4227812adf4c3cd456df8c5ad9508c4","SHA512Sum":"6c7468ce2264c7d29efe47bff3befec2bc7b498c8e37c275c791f5647efd508496f1ea36e5e78655d873c6a6a018f736c9b4b1dccaf149d6063f52efa984201b"}],"ComponentSizeInKB":4345,"CompsigList":["cp072239.compsig"],"FileList":["cp072239.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLHCWBA0HPG6.rel"],"Name":"cp072239.exe","SHA1Sum":"2ab6fc9ca9652ad6a1b9328bc4d86629e61518d6","SHA256Sum":"7669c6465ab253de78752bee6987050ed4227812adf4c3cd456df8c5ad9508c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_398e119217b248ff9b16429639","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068740.exe","SHA1Sum":"ccd011f0dd5486cf962427728d45682ccbc8654c","SHA256Sum":"0f9828da4575730c65185ef212845802818e87a98b31768ded464df8ac7b544a","SHA512Sum":"0b83bcd9df24c7b040e0a60994a490486636e33db2cf0c53bd8d17d0c1fa12eff273425ebbbf32d9ad9d6e7a7ddbdd3c37f364f24554f3177595c9215f8eac21"}],"ComponentSizeInKB":3960,"CompsigList":["cp068740.compsig"],"FileList":["cp068740.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKETG3.rel"],"Name":"cp068740.exe","SHA1Sum":"ccd011f0dd5486cf962427728d45682ccbc8654c","SHA256Sum":"0f9828da4575730c65185ef212845802818e87a98b31768ded464df8ac7b544a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_129ea91123b74a9c988498381b","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","SHA1Sum":"e104b26a880d4d30af200bc6fdd0912905b2c932","SHA256Sum":"38a96575f91b2ebf28e56cc1ef947119f00cf3eb99842324c1c351cc1c7c0361","SHA512Sum":"09d645265e80f413b4f0a90e1eaf58b76248ff578a168b69707a1e219025982c3dd566e54675ddbab56e045551185339108c9ed870121d2aeafbe3125bc4568c"}],"ComponentSizeInKB":9631,"CompsigList":["firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/CP068915.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/MPK7825Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068915.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068915.scexe"],"Name":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","SHA1Sum":"e104b26a880d4d30af200bc6fdd0912905b2c932","SHA256Sum":"38a96575f91b2ebf28e56cc1ef947119f00cf3eb99842324c1c351cc1c7c0361","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c7883e497ac44e0bd4a809faf","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070946.zip","SHA1Sum":"9e47b9195758aa2c8a0eaeb4ce4f9b8eb1eb2e34","SHA256Sum":"d86676117d4e00609e7cc9c14077d016dd541417ba9d9f47318d99f49afc6d75","SHA512Sum":"1a4e9022f5b00d64a724d6ccba654c97a36229a4db0e6a943dc3f2e945605f109c9fd06884e62d80b76b3caf5676b583acef37117529e0b232fec5d82ed1aab5"}],"ComponentSizeInKB":19508,"CompsigList":["CP070946.compsig"],"FileList":["/CP070946_BUILD_4.data","/CP070946.vmexe64","/CP070946.vmfile","/CP070946_VMw.zip","/CP070946.xml","/payload.json","/CP070946_VMw.zip/index.xml","/CP070946_VMw.zip/vendor-index.xml","/CP070946_VMw.zip/metadata.zip","/CP070946_VMw.zip/vib20/CP070946/HPE_bootbank_CP070946_HPD8.4-8.0.0.20613240.vib","/CP070946_VMw.zip/metadata.zip/vendor-index.xml","/CP070946_VMw.zip/metadata.zip/vmware.xml","/CP070946_VMw.zip/metadata.zip/vibs/CP070946--2975616020979096983.xml","/CP070946_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070946_HPD8.4-8.0.0.20613240.xml"],"Name":"CP070946.zip","SHA1Sum":"9e47b9195758aa2c8a0eaeb4ce4f9b8eb1eb2e34","SHA256Sum":"d86676117d4e00609e7cc9c14077d016dd541417ba9d9f47318d99f49afc6d75","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070946","Version":"HPD8.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcf5358eccd846f48b83981d44","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"CP070921.zip","SHA1Sum":"3fb3510fc3a28d5348ca1e8c23d57fce97d57336","SHA256Sum":"ca55649dda327a405b88c9b2b8f28d4dc824a12c71a59ea568da21946d9981dc","SHA512Sum":"affb53f6fc2aa33ad131a2f449847040c95b2eaaaae94575f5ddc16bab22b3aed92563ac22657c2582534e04743998480f1d931f1e860f610592c5efd9df3be9"}],"ComponentSizeInKB":22015,"CompsigList":["CP070921.compsig"],"FileList":["/CP070921_BUILD_2.data","/CP070921.vmexe64","/CP070921.vmfile","/CP070921_VMw.zip","/CP070921.xml","/payload.json","/CP070921_VMw.zip/index.xml","/CP070921_VMw.zip/vendor-index.xml","/CP070921_VMw.zip/metadata.zip","/CP070921_VMw.zip/vib20/CP070921/HPE_bootbank_CP070921_HPK6.2-8.0.0.20613240.vib","/CP070921_VMw.zip/metadata.zip/vendor-index.xml","/CP070921_VMw.zip/metadata.zip/vmware.xml","/CP070921_VMw.zip/metadata.zip/vibs/CP070921-7651242142968994756.xml","/CP070921_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070921_HPK6.2-8.0.0.20613240.xml"],"Name":"CP070921.zip","SHA1Sum":"3fb3510fc3a28d5348ca1e8c23d57fce97d57336","SHA256Sum":"ca55649dda327a405b88c9b2b8f28d4dc824a12c71a59ea568da21946d9981dc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6","VibList":[{"Name":"CP070921","Version":"HPK6.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi  -  VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6ea014dda134467984cb0d935d","SupportedDevices":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070981.zip","SHA1Sum":"73c07e56d48c34f581a379af16add1ae7ab8ece3","SHA256Sum":"a5253d078991e41e9101735fd4703915dbb64283a608eecae2ca8a61a06a6653","SHA512Sum":"575ccd05cd8f67139ed2d715cb5b41d5ca73d981de6d940af092822eb9e181934af857702c28be29c8f241dc6d2138f7ba6c7065c113b8c97bd223ac44de04d3"}],"ComponentSizeInKB":19840,"CompsigList":["CP070981.compsig"],"FileList":["/CP070981_BUILD_1.data","/CP070981.vmexe64","/CP070981.vmfile","/CP070981_VMw.zip","/CP070981.xml","/payload.json","/CP070981_VMw.zip/index.xml","/CP070981_VMw.zip/vendor-index.xml","/CP070981_VMw.zip/metadata.zip","/CP070981_VMw.zip/vib20/CP070981/HPE_bootbank_CP070981_HPD4.1-8.0.0.20613240.vib","/CP070981_VMw.zip/metadata.zip/vendor-index.xml","/CP070981_VMw.zip/metadata.zip/vmware.xml","/CP070981_VMw.zip/metadata.zip/vibs/CP070981--7102409209499076412.xml","/CP070981_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070981_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070981.zip","SHA1Sum":"73c07e56d48c34f581a379af16add1ae7ab8ece3","SHA256Sum":"a5253d078991e41e9101735fd4703915dbb64283a608eecae2ca8a61a06a6653","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070981","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c832462f234d48aa80ae236838","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-6.8.0-7_amd64.deb","SHA1Sum":"fd958e96aebc7a0cb49a5cf84da4e20f51e96ae5","SHA256Sum":"c63f8229ebee5bef3804425b43186d81ff3a114d563b1672143b4a01fd854ada","SHA512Sum":"d9a7b0a14486d605161a8269f5a4a755e054e0544c80a49bb9539090b505b55a638e2ac3046267d84a1587300f674e3185a8fd5ec70caa3ae4622cafc292015a"}],"ComponentSizeInKB":19111,"CompsigList":["sut-6.8.0-7_amd64.compsig"],"FileList":["./README.txt","./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/lib/x86_64-linux-gnu/libQt5Core.so.5","./opt/sut/lib/x86_64-linux-gnu/libdouble-conversion.so.3","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libpcre2-16.so.0","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/doc/sut/changelog.gz","./usr/share/doc/sut/copyright","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70"],"Name":"sut-6.8.0-7_amd64.deb","SHA1Sum":"fd958e96aebc7a0cb49a5cf84da4e20f51e96ae5","SHA256Sum":"c63f8229ebee5bef3804425b43186d81ff3a114d563b1672143b4a01fd854ada","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.8.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Ubuntu Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fce09ae5801e4c42b353735616","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U72","I46","U71","R14","A66","A66","U68","HPE ProLiant DL380m Gen12","U72","U68","U69","U69","H10","U54","U54","U57","U65","H11","A58","A59","U66","U68","U74","U71","U77"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071581.exe","SHA1Sum":"1c6ab55ae82c217f649f562cd27112c51147fcb5","SHA256Sum":"ecfd2a269d4b57b39cf2c0c2bd02108755d4c5eac2be3ac8bd88ecbf2a015abf","SHA512Sum":"02b3e5f6daae1e011a5a54bf31d2646407e49fdbe1736cd663fb881b6a3e6f742d6c01656aa12135bbceef1efc0dcaffcd0a5755a646079787b1d2a6c528a173"}],"ComponentSizeInKB":33434,"CompsigList":["cp071581_part1.compsig","cp071581_part2.compsig"],"FileList":["A48_4.04_04_02_2026.signed.flash","cp071581.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071581.exe","SHA1Sum":"1c6ab55ae82c217f649f562cd27112c51147fcb5","SHA256Sum":"ecfd2a269d4b57b39cf2c0c2bd02108755d4c5eac2be3ac8bd88ecbf2a015abf","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6230481f66494d54afb86d2b24","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a41-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"863476cbf2d3daa8925f205d0013ebd3dc2691f1","SHA256Sum":"537bdba65dd5ca25230edc9e4be2c1c3f3edf8705e129c4ba72d5e1794548a7a","SHA512Sum":"b47296156dd17511ee079e86626c56c798dd7c012b3a2a2859792a02a41f6c5573e22e2d0980d965211c299a195169219e23c13cda5ee0ad8b980cad3142f3ea"}],"ComponentSizeInKB":17520,"CompsigList":["firmware-system-a41-3.80_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/A41_3.80_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/CP072020.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072020.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072020.scexe"],"Name":"firmware-system-a41-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"863476cbf2d3daa8925f205d0013ebd3dc2691f1","SHA256Sum":"537bdba65dd5ca25230edc9e4be2c1c3f3edf8705e129c4ba72d5e1794548a7a","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_baf932484c904f228a81c0690d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.rpm","SHA1Sum":"706e583477a7e996f71e9b1044822e0d48ca013e","SHA256Sum":"3482450d5607fe67b35a712ad0b30121877c1261d46cb4bca171f9f28af9999d","SHA512Sum":"0f65ae381db703dcb22ace23464191e301ff7bea60e1cdef5e03111dd13841eed19a5ee904db711123ab2ad8ec9c9cb57c3bbcd650fdcc590573b97b9e040d7d"}],"ComponentSizeInKB":2639,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/06","./usr/lib/.build-id/06/c91c827e1c797a4ecb27d3e6a56d84b74d22df","./usr/lib/.build-id/10","./usr/lib/.build-id/10/d947fac5ec503d927e58fdfa821a634829738e","./usr/lib/.build-id/16","./usr/lib/.build-id/16/bfa88252e0d166cd5142998f8e863fe0c8fff8","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/f05f986f49aa67602464f7e33bf768f1614fae","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/48767f2130a07febc84c74cb5fa7a9620e64de","./usr/lib/.build-id/40","./usr/lib/.build-id/40/a3981455e5891a562f0fd698351a0f02bba6ae","./usr/lib/.build-id/4a","./usr/lib/.build-id/4a/0e36cb854a52462d7e096baf4fd6efaa3af81f","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/528ea5eb8f7481b97d12c44e480dd4d3e36026","./usr/lib/.build-id/60","./usr/lib/.build-id/60/26c9c6dafc8ae663e32176881a01f7b2c950ee","./usr/lib/.build-id/64","./usr/lib/.build-id/64/22de79525b447ddb1448745f5d8635f9e32fcb","./usr/lib/.build-id/69","./usr/lib/.build-id/69/e6b7a70d8da5c1666fce5e0fc1e1e1a8659184","./usr/lib/.build-id/87","./usr/lib/.build-id/87/f7169e8759f0e55131800404777eff6aa87655","./usr/lib/.build-id/88","./usr/lib/.build-id/88/7f1fd08f5cf3bc68002b8e4d98041e537bd2d9","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/4d69ff3b5f35a79957a59da55975a9fb1f7eab","./usr/lib/.build-id/91","./usr/lib/.build-id/91/03097315ab544a74dd3027ff83d1ddf7d12640","./usr/lib/.build-id/94","./usr/lib/.build-id/94/8aad76812eeaf5cf8dfea3b66aaeec21c00b3c","./usr/lib/.build-id/a3","./usr/lib/.build-id/a3/aac8cc43a7b1ae248e693e47d5b17298f52127","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b1abfeaa9011b0db9af18f2b3be92b6eecdc2f","./usr/lib/.build-id/ad","./usr/lib/.build-id/ad/c70fdf8790b5999a7b560aac69680db7ed2fe7","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/ff1f3f8335059454c4aabac82dc7040fa04881","./usr/lib/.build-id/cd","./usr/lib/.build-id/cd/0c01094285274e728b2160a1cce6afb805bc12","./usr/lib/.build-id/df","./usr/lib/.build-id/df/8140d774c81739357a45be24834702d609e668","./usr/lib/.build-id/e2","./usr/lib/.build-id/e2/4e91897066b8f592a295c0a7fba68dfec65156","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/92e5dfc914e9e6ba53a93380a805d39f77e168","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.rpm","SHA1Sum":"706e583477a7e996f71e9b1044822e0d48ca013e","SHA256Sum":"3482450d5607fe67b35a712ad0b30121877c1261d46cb4bca171f9f28af9999d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.rpm","SHA1Sum":"b8aa9f57a4f706d4143aa8f5690c6ee2fd7e9e05","SHA256Sum":"078a3186b7835a03421a76383bbae57a29617cf4e549835b4a6984394c115782","SHA512Sum":"f22ea14f77a10b773ce66ee2aaaea61bc34b4e00a6afe0f6308e4d4eb9774324dc82516e2cbefd95463f8aa8ee9b0f242256155a6c754f4794e81ac0a5228105"}],"ComponentSizeInKB":2751,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/03","./usr/lib/.build-id/03/ca921d2fe77722e760b930268fb2670170af32","./usr/lib/.build-id/08","./usr/lib/.build-id/08/baad327f9d93c712e9a2f70872401f83bb2610","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/d83fb3a1a9ce47ed1981e64f9168d33cf007ab","./usr/lib/.build-id/11","./usr/lib/.build-id/11/06e45f9c6dd63b0f749e014e6b4821eb528b85","./usr/lib/.build-id/11/6ed93595afb4ff5cdcee3c83ed9cacfb6643dc","./usr/lib/.build-id/12","./usr/lib/.build-id/12/e8a74bb3ef71c820a2f9a798f380c85f046e04","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/f81423a6ed6bbbcf4d6500e25e4ae95a101f78","./usr/lib/.build-id/1f","./usr/lib/.build-id/1f/5afa2155c8bf34ad4cbfbf07c092301b6d425e","./usr/lib/.build-id/21","./usr/lib/.build-id/21/a3e72c8cc6ffcbdb5a2fe1aa0a1698c884f121","./usr/lib/.build-id/24","./usr/lib/.build-id/24/3c71a5ce053703c57ae72bff7ff3edaa8b70ef","./usr/lib/.build-id/29","./usr/lib/.build-id/29/bc9ac72374bf1ead7d7fbb3a68586525f8d122","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/3597a25617829251fe6575e48303e5d779f635","./usr/lib/.build-id/2f","./usr/lib/.build-id/2f/50e6da4622e9c37dcbcda8a03bbc16f0e3003e","./usr/lib/.build-id/35","./usr/lib/.build-id/35/474bed860e0c9464ee2ffeb7c27ed242b9cd71","./usr/lib/.build-id/39","./usr/lib/.build-id/39/d5b8f283de89dcbec0a80d65f715c9dddb32be","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/e840f9b65b5094da00b10c4e7882a20afc8e87","./usr/lib/.build-id/46","./usr/lib/.build-id/46/40ee3a443f92e3798c917d3da419d51231f59d","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/c55c12c1a7d2d0b1812c40111ba4af0a9104da","./usr/lib/.build-id/60","./usr/lib/.build-id/60/41505d735f13a982046a232aadec3d8c25a697","./usr/lib/.build-id/66","./usr/lib/.build-id/66/2367f423960b6da7701bdea49460f12224c51c","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/58de3cbc4ed51441d7eed34781b1d679f8edd2","./usr/lib/.build-id/71","./usr/lib/.build-id/71/7bda78ce72488fce8a128d5d85fcb1f6953536","./usr/lib/.build-id/74","./usr/lib/.build-id/74/d6e21fb55d9070408b241aaff1b5a7e5552bc6","./usr/lib/.build-id/75","./usr/lib/.build-id/75/f992ae2b6fcc108f2d4a6cd47aeb3d7fcb9ff0","./usr/lib/.build-id/81","./usr/lib/.build-id/81/e5bccf1d755ea4b810497b0e86b837be8c498b","./usr/lib/.build-id/ab","./usr/lib/.build-id/ab/4ce8a002c51911c919c0d0d1ea36bec960e585","./usr/lib/.build-id/ba","./usr/lib/.build-id/ba/64fa1e1ee642e6bc52da2c3d1f59b17c09d228","./usr/lib/.build-id/be","./usr/lib/.build-id/be/7f853647e0584031e9002c3c33875cef4229c1","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/4f18e7bbf2dc66414d18abe38d2a1a5448efcd","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/51f1fbd417dc91655307268c5bae1dd7f72fc4","./usr/lib/.build-id/d0/7245b776b35d1241b8a63455719ac554428bd8","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/7364aa3b349f13140e4c810505526efb67bd02","./usr/lib/.build-id/da","./usr/lib/.build-id/da/759ed4c2819545b30c116944cd70a9a6d9ba7c","./usr/lib/.build-id/da/a6ac4851ddaa965a909dea5bb446fe02a8c5cc","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/59fbb1b9f5de83ecfd0f0519013a21d90babc5","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/821c08e13b6c839c67a9cf6deec92e22bbdd18","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/95eb07d5f89a040769eb65a627ec377a7f4674","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/1d242776d2ebc978fa45b360b2bab6e52746d9","./usr/lib/.build-id/ee","./usr/lib/.build-id/ee/001a94655a76cb7d2f5ece0b2a2da20ebc0e34","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/a04857415e7ae02b2474119c93ea38293aa4eb","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/5cc6c4bc5520aa7f6f9cce5d641e8108af5ef6","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/2014543b4c6ddce1deb4359d19b90a578d0df0","./usr/lib/.build-id/fd","./usr/lib/.build-id/fd/6c6f116d2eaf63fef96b9268c47e36a4595e45","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.rpm","SHA1Sum":"b8aa9f57a4f706d4143aa8f5690c6ee2fd7e9e05","SHA256Sum":"078a3186b7835a03421a76383bbae57a29617cf4e549835b4a6984394c115782","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 7 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4c6e93ae47304847bd2c986692","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p56_CFGID7p2_K97342_800100D3.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3909.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p56_CFGID7p2_K97470_800100DE.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3909.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3909.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-intel-1.36.0-1.1.x86_64.rpm","SHA1Sum":"d0a4dcfcebf46871cbb617b5e3e632c10f55f851","SHA256Sum":"5a15b675600e6473dacc90f312ccd549fce874b8e87ecbc0584433d5a4c14e9a","SHA512Sum":"ff0ea65168ba4de98fc21751638497ba1ce9d93071bfc77f15da344622ceee8ed035dede4053a5185d1bb003f2e3236d246d68d241afa54808472e254c673b97"}],"ComponentSizeInKB":5883,"CompsigList":["firmware-nic-is-intel-1.36.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/CP070390.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/CP070390.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_X710DA2_9p55_CFGID7p2_K97470_8000FE06.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_X710DA2_9p56_CFGID7p2_K97470_800100DE.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_X710DA2_OCP3_9p55_CFGID7p2_K97342_8000FDFD.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_X710DA2_OCP3_9p56_CFGID7p2_K97342_800100D3.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.36.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070390.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070390.scexe"],"Name":"firmware-nic-is-intel-1.36.0-1.1.x86_64.rpm","SHA1Sum":"d0a4dcfcebf46871cbb617b5e3e632c10f55f851","SHA256Sum":"5a15b675600e6473dacc90f312ccd549fce874b8e87ecbc0584433d5a4c14e9a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"1.36.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bfe9bee2e6884849874b0f4ec7","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070566.exe","SHA1Sum":"92355eab30f42ffb9ac51aaaef09bc9bf1f5718f","SHA256Sum":"cd627b4e8c4fdd69357d68ec323f4fe2229429f7ae08b0aa30b2d291db14cc69","SHA512Sum":"78965fb6056bcaad72253502110b8a440b1934b12f8b7dfdd20ccfb79ddcf88af2afef9d0e978f94a5d579c3538a78bd99c6b3e6e0f59741fd656b9d1e09fb25"}],"ComponentSizeInKB":834,"CompsigList":["cp070566.compsig"],"FileList":["cp070566.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"Name":"cp070566.exe","SHA1Sum":"92355eab30f42ffb9ac51aaaef09bc9bf1f5718f","SHA256Sum":"cd627b4e8c4fdd69357d68ec323f4fe2229429f7ae08b0aa30b2d291db14cc69","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.7.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2fe26351e0574dc19e3b9b2986","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"cp068636.exe","SHA1Sum":"461944992100242d97babe2abc7fbe320ee1a718","SHA256Sum":"3ff362b26afe88ce3714c2b38fad6888b4bb70f19c4f630d729e6e86803710c1","SHA512Sum":"258b90c3908a1e6211198e7eb78a6ac35d14aec066fc216caca13681b06e4116976b1bd181fb35f7dbc3f53c2b7f33372cd867425feb30dbf286a41bc0b5acd3"}],"ComponentSizeInKB":5844,"CompsigList":["cp068636.compsig"],"FileList":["cp068636.xml","cpqsetup.exe","KPE80X0AHPK5.rel","payload.json","setup.dll"],"Name":"cp068636.exe","SHA1Sum":"461944992100242d97babe2abc7fbe320ee1a718","SHA256Sum":"3ff362b26afe88ce3714c2b38fad6888b4bb70f19c4f630d729e6e86803710c1","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bf4346a35984e31809f5fa031","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068731.exe","SHA1Sum":"b5d626da7d6e17b54a903a95414f2f985d831aed","SHA256Sum":"d407186cef9820b83cc17ef223acb56e90fb3d94f3d2870e24665d0b9a01354f","SHA512Sum":"f4473bd4f50f5681018b71469b2f632edb7b6400dc4e8bc1f619bad36db31d674dee4caf545cef5e52054bd75dc74f0cb9dc8e1bd442e506e4ebe974b8737079"}],"ComponentSizeInKB":4212,"CompsigList":["cp068731.compsig"],"FileList":["cp068731.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNESD8.rel","setup.dll"],"Name":"cp068731.exe","SHA1Sum":"b5d626da7d6e17b54a903a95414f2f985d831aed","SHA256Sum":"d407186cef9820b83cc17ef223acb56e90fb3d94f3d2870e24665d0b9a01354f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8aa7071f46d84a058e94d59287","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072011.exe","SHA1Sum":"2cc7b10811477e631fe13ccdbb5dadb2af27b67b","SHA256Sum":"53a3ce0f2ba12676c542ae1ff7ae39ca9130390fc16296c1f336f7598d5d4a20","SHA512Sum":"0deec191877b899c25d54319f6a694f4a48b0684801c50a1fe381fa5a59e88f14a67b675508ebd847b3da0c3b9103c1c59db2911d678eef44c1e717cfa87ee6b"}],"ComponentSizeInKB":24146,"CompsigList":["cp072011.compsig"],"FileList":["CHIF/","CHIF/X64/","cp069672.exe","cp069674.exe","cp069676.exe","cp069698.exe","cp069722.exe","cp069724.exe","cp072011.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"Name":"cp072011.exe","SHA1Sum":"2cc7b10811477e631fe13ccdbb5dadb2af27b67b","SHA256Sum":"53a3ce0f2ba12676c542ae1ff7ae39ca9130390fc16296c1f336f7598d5d4a20","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"TypeOfChange":"1","Version":"6.8.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Windows x64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"sut.exe","SWKeyExpectedPath":"%ProgramFiles%\\SUT\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c93e89b67f74393a23b4f024a","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A56","A56","A55","A55","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","A42","U56","U61","U60","U64","U46","I43","I45","I44","I42","U59","U63","U65","U65","U58","U63","U71","U69","U69","U68","U68","U68","U72","U70","U66","U71","U72","I46","U68","HPE ProLiant DL380m Gen12","U77","H08","H08","H10","U54","U54","U57","U65","H11","A58","A66","U74","A66","U71","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U43_3.76_05_28_2026.fwpkg","SHA1Sum":"8e4413954f8e94412c862409deca041153062ca0","SHA256Sum":"754c7c5cfe20d6c9ce3594b4cf7c22f96e02c2c5884df82c4d523cfd6d1889bb","SHA512Sum":"168c7dc795aa14cd41ebc7f9ecf4edfc51e04aebc23e5db69ae89eb4603c35a24bdadd88752e2e99144d2c0276d4f9eef6e9bdfa8f96bbb40c3d75a8c92b1b46"}],"ComponentSizeInKB":16429,"CompsigList":[],"FileList":["payload.json","U43_3.76_05_28_2026.signed.flash","U43_3.76_05_28_2026.xml"],"Name":"U43_3.76_05_28_2026.fwpkg","SHA1Sum":"8e4413954f8e94412c862409deca041153062ca0","SHA256Sum":"754c7c5cfe20d6c9ce3594b4cf7c22f96e02c2c5884df82c4d523cfd6d1889bb","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa387ee286ad4f2bbf80de0f9f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070511.zip","SHA1Sum":"4061b9f9f6c304ed2b8e7a22e31ac12f2534bdc2","SHA256Sum":"3f5bbbd969e34c7b8d95a0a4fc759beb344921cdc9559f95c42214fae5ae08ae","SHA512Sum":"aa059e21be4d3fdeaea9ddea95fe42d55999fbe7e537aff4f913b5d0b2daf90b9ca85a0f2553a7cfc0f1889e4faa016583f73836761283707dd6e2cf030ade3f"}],"ComponentSizeInKB":702,"CompsigList":["cp070511.compsig"],"FileList":["/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip","/cp070511.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.5.86.0-1OEM.900.0.24755229.vib","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/qlnativefc--6136840453486731005.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.xml"],"Name":"cp070511.zip","SHA1Sum":"4061b9f9f6c304ed2b8e7a22e31ac12f2534bdc2","SHA256Sum":"3f5bbbd969e34c7b8d95a0a4fc759beb344921cdc9559f95c42214fae5ae08ae","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"5.5.86.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c77b3aa54094ea49e74eddd39","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","SHA1Sum":"260cf2a3959d61cec6498d499d1382d889522436","SHA256Sum":"3db0946d793f8aa938f3a7d7a88b95b4f5f5ea92a9944e5efd0fe3566e58d84a","SHA512Sum":"461db09ccb156859373b626d4848c8423c64fa33ca054b03e10804f740a338cf8c7e77df4d08e1aa51f4e4808162ea774fd738a743f5684bd9b61685010ebaa0"}],"ComponentSizeInKB":6085,"CompsigList":["firmware-hdd-8173816d98-HPD6-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/CP068839.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068839.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068839.scexe"],"Name":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","SHA1Sum":"260cf2a3959d61cec6498d499d1382d889522436","SHA256Sum":"3db0946d793f8aa938f3a7d7a88b95b4f5f5ea92a9944e5efd0fe3566e58d84a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f94eb54b3b1c4a1da2fcfa19d0","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0","10.0","9.0","8.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp067917.exe","SHA1Sum":"8e236b7c21bf411031e0a6bc878b1f598742fa17","SHA256Sum":"d24504e9f532e4921eb3bf54c9755aa2c30831e447c070eadf5482fe84a1d58d","SHA512Sum":"55815791fac06dcc6d10c907eed4cf6d7fbc25069507f2b83f374f1de197fb3a0b7eddd2111677e3fd4d8235a1d21c920215b6dce9c7eb5672b0edd60a26fccf"}],"ComponentSizeInKB":726,"CompsigList":["cp067917.compsig"],"FileList":["cp067917.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"Name":"cp067917.exe","SHA1Sum":"8e236b7c21bf411031e0a6bc878b1f598742fa17","SHA256Sum":"d24504e9f532e4921eb3bf54c9755aa2c30831e447c070eadf5482fe84a1d58d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"TypeOfChange":"1","Version":"1.2.1.69"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","SWKey":"SmartDQa.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"62.0.28.64"}]}]}]},"Name":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"hpepqiesrv.exe","SWKeyExpectedPath":"%programfiles%\\hpe\\hpepqiesrv"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ebffb2cdb5344b9b7b9694171","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0655","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-103c-193f159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U30","U32","U37","I43","I42","U34","A40","U31","U31","U36","HPE ProLiant ML150 Gen10 Server","U33","U40","U38","U38","A43","U46","U46","U50","I44","U61","U60","U47","U47","A42","A43","A42","A48","A47","A46","HPE Apollo 6500 Gen10 Plus (Chassis)","U48","A42","A43","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":8,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071877.exe","SHA1Sum":"759677e3840571bd9ebf3fbe6ac652409f9f151a","SHA256Sum":"12d2cd64c423ee32699b2686487a292f7b1e22b504dc4795ba6fa43cfd77958c","SHA512Sum":"6d3ec9125276a54edda677a7c039f509aa1e0ac29570ca7eb18a3f257edd2a1a29916602df5a4dab908f88b8934d78445c14a8fdf94b299e3dceeb545033e26e"}],"ComponentSizeInKB":231058,"CompsigList":["cp071877_part1.compsig","cp071877_part2.compsig","cp071877_part3.compsig","cp071877_part4.compsig","cp071877_part5.compsig","cp071877_part6.compsig","cp071877_part7.compsig","cp071877_part8.compsig"],"FileList":["cp071877.xml","cpqsetup.exe","MlnxDriverInstaller.dll","MLNX_WinOF2-25_4_50020_All_x64.exe"],"Name":"cp071877.exe","SHA1Sum":"759677e3840571bd9ebf3fbe6ac652409f9f151a","SHA256Sum":"12d2cd64c423ee32699b2686487a292f7b1e22b504dc4795ba6fa43cfd77958c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.4.50020.0"}],"InstallationDependency":{},"Name":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_602639d355fd43f18b42a7d4d7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d1590037d","a6b1a447-382a-5a4f-15b3-101f159003fe"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72","A42","A43","A43","A47","A48","U50","U47","A46","U47","A42","U54"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069551.exe","SHA1Sum":"0f6a563758edbd7548fc32917e79375c18fcddaf","SHA256Sum":"2bafd7d88d662165a8e744dc76355866aa66805ca28e367e8c97e419f0887fdb","SHA512Sum":"a855b6484ff605e570fd60dc41020eb4cb4aca4f2b2aba1fdc0ee013025e7dab55bd08b7eed9a847d167f5aab0333074cf0260b46397000da111bcac9061a5bd"}],"ComponentSizeInKB":1013,"CompsigList":["cp069551.compsig"],"FileList":["cp069551.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069551.exe","SHA1Sum":"0f6a563758edbd7548fc32917e79375c18fcddaf","SHA256Sum":"2bafd7d88d662165a8e744dc76355866aa66805ca28e367e8c97e419f0887fdb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b70a0115b54549caa0ab62a22d","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070958.zip","SHA1Sum":"075ef07e003ee69d4a16509f83a826b389107784","SHA256Sum":"796e933eb1c001bf17a2cd34b137037289fffbf76c8b0aa20263db42933029b5","SHA512Sum":"b137a06a7425e6f1727008d07754c32fb006f5c8e9e278fd3c43a2193984e6a81717cc2946703a9d34ead9afae9596ba0eb4cd75f14268b29f9b116685ac86d9"}],"ComponentSizeInKB":18402,"CompsigList":["CP070958.compsig"],"FileList":["/CP070958_BUILD_3.data","/CP070958.vmexe64","/CP070958.vmfile","/CP070958_VMw.zip","/CP070958.xml","/payload.json","/CP070958_VMw.zip/index.xml","/CP070958_VMw.zip/vendor-index.xml","/CP070958_VMw.zip/metadata.zip","/CP070958_VMw.zip/vib20/CP070958/HPE_bootbank_CP070958_HPG1.3-8.0.0.20613240.vib","/CP070958_VMw.zip/metadata.zip/vendor-index.xml","/CP070958_VMw.zip/metadata.zip/vmware.xml","/CP070958_VMw.zip/metadata.zip/vibs/CP070958--6853494265629143548.xml","/CP070958_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070958_HPG1.3-8.0.0.20613240.xml"],"Name":"CP070958.zip","SHA1Sum":"075ef07e003ee69d4a16509f83a826b389107784","SHA256Sum":"796e933eb1c001bf17a2cd34b137037289fffbf76c8b0aa20263db42933029b5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070958","Version":"HPG1.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7bcf258c03cd4168a6f023bf56","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068882.exe","SHA1Sum":"031384c5ece921ed56232f8a8a516607c0dc5069","SHA256Sum":"008de08cd748ceca2ad8ee3a9bf06ed2203987e0a6e20c01668de7c5a3fc8984","SHA512Sum":"88bd0d28e6f21a5abb3947fac7844d3d04a08d8a320b8c8b94f856c551fc3f0e34d002987285478905920693152e9123a8dfabc65883475451cb63ee389edbd1"}],"ComponentSizeInKB":895,"CompsigList":["cp068882.compsig"],"FileList":["cp068882.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"Name":"cp068882.exe","SHA1Sum":"031384c5ece921ed56232f8a8a516607c0dc5069","SHA256Sum":"008de08cd748ceca2ad8ee3a9bf06ed2203987e0a6e20c01668de7c5a3fc8984","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.736.3.0"}],"InstallationDependency":{},"Name":"MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2022 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d532712810154a58b955eafff4","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3438-304b584e5845","Version":"HPK6"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3052-3030-3936-304b584e5a55","Version":"HPK6"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-3053-3130-3932-304b584e5846","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Micron_7450_M7450ALLHPK6.fwpkg","SHA1Sum":"48e62474c0a88b83452f480b3da1b55025c07154","SHA256Sum":"aa9331908842d084644d563bb3c855d373ff9fbd5ea29eac650902ac2138dbd8","SHA512Sum":"5769e975c119541d90f8919467fb4a147de67bc19250154b5f01ce552344b1b86172a2ec521d00af612fd0ce25a494069176733851b9c7fed358b775553fa205"}],"ComponentSizeInKB":2330,"CompsigList":[],"FileList":["Micron_7450_M7450ALLHPK6.HPb","Micron_7450_M7450ALLHPK6.xml","payload.json"],"Name":"Micron_7450_M7450ALLHPK6.fwpkg","SHA1Sum":"48e62474c0a88b83452f480b3da1b55025c07154","SHA256Sum":"aa9331908842d084644d563bb3c855d373ff9fbd5ea29eac650902ac2138dbd8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KXNXE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KXNZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VS001920KXNXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f6c84bee6ee48b58e6726b4f1","SupportedDevices":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072028.exe","SHA1Sum":"11a7f4fca9ace6730abcf2e78dbf873732e3a386","SHA256Sum":"d08f2db27f1401063d1b6d78e75ea4da7f778bedfcba9397d83297cef07899e7","SHA512Sum":"ac7747a34c49a8ea1a2c44cd3508326c61a8c0fadf251fa4d1bc6651feb02851abd38f16963c74e51b016341b0f848b6e99fad8685d0fda201221d4a4a98134d"}],"ComponentSizeInKB":8918,"CompsigList":["cp072028.compsig"],"FileList":["cp072028.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_3.76_05_28_2026.signed.flash"],"Name":"cp072028.exe","SHA1Sum":"11a7f4fca9ace6730abcf2e78dbf873732e3a386","SHA256Sum":"d08f2db27f1401063d1b6d78e75ea4da7f778bedfcba9397d83297cef07899e7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bd88dbf49ea846a38b5c4e7173","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.rpm","SHA1Sum":"f6c7b581b604132e62172580baefe536875b7312","SHA256Sum":"9f4034ffa2a7ed4d2dbe9bcfbecbd10356efa30f9f1b2513ffea04f9b10cfbc2","SHA512Sum":"f373f8315e309f8aae0cedcf882075f4d8fcbdf731fbe34bba997c14a0c2c94f681d270fea82ddf8c3638243a4e1dbeeefa61fdf2fd14a1abad0abedfd433295"}],"ComponentSizeInKB":5151,"CompsigList":["firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/CP072133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/M52004TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072133.scexe"],"Name":"firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.rpm","SHA1Sum":"f6c7b581b604132e62172580baefe536875b7312","SHA256Sum":"9f4034ffa2a7ed4d2dbe9bcfbecbd10356efa30f9f1b2513ffea04f9b10cfbc2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c10a36f93d7a4edd8c0659437e","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072035.exe","SHA1Sum":"7f7605e94ca39113ac0f6d74b52d2de581ae04cc","SHA256Sum":"0ac5c89b7b387ab2765e950992089fc5195c77a70e6fde76a5f220b7fd66fb36","SHA512Sum":"7f5cb205ddc90985a554fe9916c6ff0dc2b6a18a5409c5f778cb0ea43e3aa8d14096c2de7356e439cb1b46af3275ac8bc31b1276ad2267d2c47d3dd9f414753a"}],"ComponentSizeInKB":8923,"CompsigList":["cp072035.compsig"],"FileList":["cp072035.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_3.76_05_28_2026.signed.flash"],"Name":"cp072035.exe","SHA1Sum":"7f7605e94ca39113ac0f6d74b52d2de581ae04cc","SHA256Sum":"0ac5c89b7b387ab2765e950992089fc5195c77a70e6fde76a5f220b7fd66fb36","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b764aeb04cc741458bcfaa7a03","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Toshiba_MG08Air_TAMG08ADAnG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-3047575a5654","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","SHA512Sum":"c2a0008f42757f359b3fc7337809d2da708d86102fcaa3eca3f349a873341dd533d93c96802da34b79bccd8c1dae5da72464cb7ba0f6e0862602f3d17cf03316"}],"ComponentSizeInKB":1242,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAnG3.HPb","Toshiba_MG08Air_TAMG08ADAnG3.xml"],"Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047575a5654"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB004000GWZVT","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWZVT","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9077ed7856b1465a8395a8ce4b","SupportedDevices":["4d2340a5-3042-3430-3030-3047575a5654"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4706"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.rpm","SHA1Sum":"10429e62caec45e566bbe7b1cdbb6b93493b46ce","SHA256Sum":"f03a2e26a947031d4224376f1f315801c1489e25de531925d1faccf612f775cf","SHA512Sum":"d16335d02f5b254fada22fb835bc3ef1044f3a04e72ba227b7cbbea37468a4e89d0a96a1d42a7c707d7d6faac11a61065ae12da4f8a0f4b13acc02430d199cf2"}],"ComponentSizeInKB":7714,"CompsigList":["firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/CP072408.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072408.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072408.scexe"],"Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.rpm","SHA1Sum":"10429e62caec45e566bbe7b1cdbb6b93493b46ce","SHA256Sum":"f03a2e26a947031d4224376f1f315801c1489e25de531925d1faccf612f775cf","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.18"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b073bab29f3c444793dc894ba0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","16.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A47","A48","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U37","A42","U56","U27","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","SHA1Sum":"80425a54b8fdc1dbce3eb24679ae762887f48dfd","SHA256Sum":"6a87432ff1cb3991599af9c9179cd9186b5f0e32b087f50fbe3d4eb1325790ee","SHA512Sum":"0aa6755e763bd9f8e576a4a4db0f10bf3e629ea03d72b30262949d33a0affcccfa155c23ee0e9d5fd673c04cac6eae7c8c28d54276f7c3e705287d5e22aacc65"}],"ComponentSizeInKB":5191,"CompsigList":["firmware-hdd-35fd24601f-HPD5-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/CP068914.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068914.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068914.scexe"],"Name":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","SHA1Sum":"80425a54b8fdc1dbce3eb24679ae762887f48dfd","SHA256Sum":"6a87432ff1cb3991599af9c9179cd9186b5f0e32b087f50fbe3d4eb1325790ee","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_431afbfd2b4549a49c85282054","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"IEGen10_0.2.3.0.fwpkg","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","SHA512Sum":"849b4d0539646d5ce13430bd99519c35013fd871221b8269d52f5cbabc87b9190c532a30b6c86736f602943e9f8c7ae4ba6aba27f4d0901c076a3138d4a5c30b"}],"ComponentSizeInKB":16409,"CompsigList":[],"FileList":["IEGen10_0.2.3.0.signed.bin","IEGen10_0.2.3.0.xml","IEGen10_0.2.3.0_B.signed.bin","payload.json"],"Name":"IEGen10_0.2.3.0.fwpkg","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40c0e7a8438342b484e5d401d2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U30","U32","U31","U31","U41","U33","U39","I43","I42","U34","U40","U37","U38","U38","U45","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070841.zip","SHA1Sum":"0f469d3d2a6b5076b32471ec69682344f16cde82","SHA256Sum":"1cc3df8cd92ce80700b398fdfcea262d72846c5d2cfdc942ec7102b7a482744d","SHA512Sum":"6a42453025b37d467f183ffd7d99dcad12785d7e68f626064a825a03d1100484d0d9cedc24ac43e9812aa49f85389eba3e151450f74c877228bd8d9ac119d14f"}],"ComponentSizeInKB":210,"CompsigList":["cp070841.compsig"],"FileList":["/cp070841.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/vib20/ixgben/INT_bootbank_ixgben_1.23.3.0-1OEM.900.0.24755229.vib","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ixgben--8289692326410911223.xml","/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-ixgben_1.23.3.0-1OEM.900.0.24755229.xml"],"Name":"cp070841.zip","SHA1Sum":"0f469d3d2a6b5076b32471ec69682344f16cde82","SHA256Sum":"1cc3df8cd92ce80700b398fdfcea262d72846c5d2cfdc942ec7102b7a482744d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"ixgben","Version":"1.23.3.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.23.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.23.3.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a51312f359a14beca16a92b191","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A59","U77","A66","A66","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","SHA1Sum":"c9b67f99ef66a6d0194dbefc1a648dc4d989d938","SHA256Sum":"482737fb747160512f4141175bfaabb9a9b5983492ce8580bc8251b8ab38dec8","SHA512Sum":"2802c4b0f0dd88b69a28af4b0c409a4cb1343a2dfc7d1bc3510d9e5d42fa48c66fa7818309d6b2eb4abf1bff5d6a8f0390a3f741cebb8befd76b18ced54f2e16"}],"ComponentSizeInKB":4998,"CompsigList":["firmware-hdd-24fe569b72-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/CP068865.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068865.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068865.scexe"],"Name":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","SHA1Sum":"c9b67f99ef66a6d0194dbefc1a648dc4d989d938","SHA256Sum":"482737fb747160512f4141175bfaabb9a9b5983492ce8580bc8251b8ab38dec8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8743e3c43b1a4290be02278153","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ca21e169e2-HPG1-14.1.x86_64.rpm","SHA1Sum":"9002b37e58ce5b91e87a6352ae81ee708e9de659","SHA256Sum":"01fde7034f962600272c1a449a433db225539453b6dafe05879ae28bfdc723a3","SHA512Sum":"7168c24b662ed046ddd0042b2a834073e71d040f03722df81f2c333e12c0489139d78ba3efa1beccb2b9c7a2d1b9b635faa4dffbedd6f697c437507944287e0c"}],"ComponentSizeInKB":6236,"CompsigList":["firmware-hdd-ca21e169e2-HPG1-14.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/CP068844.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068844.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068844.scexe"],"Name":"firmware-hdd-ca21e169e2-HPG1-14.1.x86_64.rpm","SHA1Sum":"9002b37e58ce5b91e87a6352ae81ee708e9de659","SHA256Sum":"01fde7034f962600272c1a449a433db225539453b6dafe05879ae28bfdc723a3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7b3cf9c7563743daa6b562147e","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"CP070943.zip","SHA1Sum":"535ab5414ac218884cbf9873978ef54f1efd655a","SHA256Sum":"bbbf608125dbd56d41308e8ff8b233ace6968fc8600ab0738b7f9682428a4a27","SHA512Sum":"456fee72b9cc0d305ab69b9ac68aad21dfd5ef9313ecaaede4586625089ed69ea076026f9f816eab7dfb3f1c455b7ec469dc4569bf577c05805524ccbb968bf0"}],"ComponentSizeInKB":19165,"CompsigList":["CP070943.compsig"],"FileList":["/CP070943_BUILD_6.data","/CP070943.vmexe64","/CP070943.vmfile","/CP070943_VMw.zip","/CP070943.xml","/payload.json","/CP070943_VMw.zip/index.xml","/CP070943_VMw.zip/vendor-index.xml","/CP070943_VMw.zip/metadata.zip","/CP070943_VMw.zip/vib20/CP070943/HPE_bootbank_CP070943_HPG8.6-8.0.0.20613240.vib","/CP070943_VMw.zip/metadata.zip/vendor-index.xml","/CP070943_VMw.zip/metadata.zip/vmware.xml","/CP070943_VMw.zip/metadata.zip/vibs/CP070943--985892147586158893.xml","/CP070943_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070943_HPG8.6-8.0.0.20613240.xml"],"Name":"CP070943.zip","SHA1Sum":"535ab5414ac218884cbf9873978ef54f1efd655a","SHA256Sum":"bbbf608125dbd56d41308e8ff8b233ace6968fc8600ab0738b7f9682428a4a27","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8","VibList":[{"Name":"CP070943","Version":"HPG8.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_44cf669ea6404c639e893adc61","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","SHA1Sum":"14041dc9441d51b991ae6df6f72ebc0a1c49f39f","SHA256Sum":"af3b72a13526c8d4f1efb6a3cc348f20cd4cd8f4044e559501322b932703775e","SHA512Sum":"cf56a9a1e1bfd5a28f8247765b1e90f59af058a2bb991b13b4243d0a36dc2511d48bd19d38076f08a7fe6fc5755da5084c2ef2dcf0db823098829744cbd53b3f"}],"ComponentSizeInKB":5017,"CompsigList":["firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/CP068919.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068919.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068919.scexe"],"Name":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","SHA1Sum":"14041dc9441d51b991ae6df6f72ebc0a1c49f39f","SHA256Sum":"af3b72a13526c8d4f1efb6a3cc348f20cd4cd8f4044e559501322b932703775e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d11dc139e4384368a01dad3045","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e0171a2936_0HPG6-2.1_amd64.deb","SHA1Sum":"fb2cc90644ea59db85f7c012b4053bf4a9e02e87","SHA256Sum":"a2f8ee7c30090d2319b01ad79416acc6aa852e505b09da4775fd64a79f9ce491","SHA512Sum":"ee38aeb64b85a9c5e964d9d1bd39d0594eb8a9cc7933a0d7d8a858a256e9bdfbd6cecca0a3b839a8c501ed0bc5720f20aa5d59ab0d9f18004c6cf588fa880e14"}],"ComponentSizeInKB":4491,"CompsigList":["firmware-hdd-e0171a2936_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/CP071790.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/TAMG09acHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071790.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071790.scexe"],"Name":"firmware-hdd-e0171a2936_0HPG6-2.1_amd64.deb","SHA1Sum":"fb2cc90644ea59db85f7c012b4053bf4a9e02e87","SHA256Sum":"a2f8ee7c30090d2319b01ad79416acc6aa852e505b09da4775fd64a79f9ce491","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_736373fe26494dd29398bb40cc","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"},{"DelayAfterInstallSec":180,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"firmware-d8000_0130-3.1_amd64.deb","SHA1Sum":"97d6f3ebe308326199818bdcea2405245e29bc89","SHA256Sum":"c869381e842ee45183ad0cdb0d836b6f4393da6c7e7c91b3b9577720ffc88a50","SHA512Sum":"440a3c93ec1b91b1322a8663b11f38843e1c317597523e12aa573d676682dc0cdc0f24ee189a82e1f68bbb8d7f7cb55e27a6cdcc84fb279a7d40c507efd5b854"}],"ComponentSizeInKB":2743,"CompsigList":["firmware-d8000_0130-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/CP072188.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072188.scexe","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072188.scexe"],"Name":"firmware-d8000_0130-3.1_amd64.deb","SHA1Sum":"97d6f3ebe308326199818bdcea2405245e29bc89","SHA256Sum":"c869381e842ee45183ad0cdb0d836b6f4393da6c7e7c91b3b9577720ffc88a50","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2f1f7cbc92924ddfb1e1f05b01","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"12dda8adb3ce8996e5c68af5660a4b792a6d10d0","SHA256Sum":"6071be4257c3f9a77b0ee523bdfde0e97a54bcfc368d30454ba4bf6ff3e24ad7","SHA512Sum":"e01b3af4edfbe504c5a8955b2c2ddd007507e2ac8132a3b145db4d33d4e0be96a82e37eb562cd20e9b41da5b32529e2cd72ec1a8615b1d6f5c5c3a71c099d35a"}],"ComponentSizeInKB":4811,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"12dda8adb3ce8996e5c68af5660a4b792a6d10d0","SHA256Sum":"6071be4257c3f9a77b0ee523bdfde0e97a54bcfc368d30454ba4bf6ff3e24ad7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3829a63eceed47e4a618463a0a","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"CP071317.zip","SHA1Sum":"faecc96d0bc2548fbe6f0554675d652f8adfb916","SHA256Sum":"ca5fa5049033b027104c66f47806de942e0f1ac50af52424d096ec08ba9c2fd4","SHA512Sum":"4441881f2e077e246de9daf4c732bd9e1f79515b61d3533d8d16c37f40d34cf0d39597812e918fb9dba90cb51eea1485ec9b1d6e4267fc104aa9c04f2c6172ff"}],"ComponentSizeInKB":5624,"CompsigList":["CP071317.compsig"],"FileList":["/CP071317_BUILD_3.data","/CP071317.vmexe","/CP071317.vmexe64","/CP071317.vmfile","/CP071317_VMw.zip","/CP071317.xml","/payload.json","/CP071317_VMw.zip/index.xml","/CP071317_VMw.zip/vendor-index.xml","/CP071317_VMw.zip/metadata.zip","/CP071317_VMw.zip/vib20/CP071317/HPE_bootbank_CP071317_2026.06.01.3-8.0.0.20613240.vib","/CP071317_VMw.zip/metadata.zip/vendor-index.xml","/CP071317_VMw.zip/metadata.zip/vmware.xml","/CP071317_VMw.zip/metadata.zip/vibs/CP071317-1236188951939555293.xml","/CP071317_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071317_2026.06.01.3-8.0.0.20613240.xml"],"Name":"CP071317.zip","SHA1Sum":"faecc96d0bc2548fbe6f0554675d652f8adfb916","SHA256Sum":"ca5fa5049033b027104c66f47806de942e0f1ac50af52424d096ec08ba9c2fd4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01","VibList":[{"Name":"CP071317","Version":"2026.06.01.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2995636f8942413eac7ae898cb","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068747.exe","SHA1Sum":"cce44c2241988e373511e6996b4850ffebc641bd","SHA256Sum":"88c03aed91155b0f886a5e1ff73a73101b213591ae5d5ed0c0f1968489fbf4e4","SHA512Sum":"657e215ac79880fb1345069cc32f6ddeec4897d913a4c4412990b2e5f286582ccb7aa92415ba5d33cea3845e72c01385bfb3ce448cd006f523071520b4cf67c2"}],"ComponentSizeInKB":4557,"CompsigList":["cp068747.compsig"],"FileList":["cp068747.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssATFG3.rel"],"Name":"cp068747.exe","SHA1Sum":"cce44c2241988e373511e6996b4850ffebc641bd","SHA256Sum":"88c03aed91155b0f886a5e1ff73a73101b213591ae5d5ed0c0f1968489fbf4e4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2dbde1482fdc4b03bbfab4b3b3","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ef93133161_0HPD4-2.1_amd64.deb","SHA1Sum":"86ad753d327a978060428b246d426e0094a61b00","SHA256Sum":"ed183371daa2069723886222b54416c76864b41b0b5ea1512f790334e0df86f7","SHA512Sum":"86b088b9d0c525e554bb5f0098a1290ae169bc11490bf3856d9a925481c6ba1da1b18a62e754bdb72352b58e23010163e121093882573a6a70f5896990275bb9"}],"ComponentSizeInKB":3822,"CompsigList":["firmware-hdd-ef93133161_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/CP071746.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071746.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071746.scexe"],"Name":"firmware-hdd-ef93133161_0HPD4-2.1_amd64.deb","SHA1Sum":"86ad753d327a978060428b246d426e0094a61b00","SHA256Sum":"ed183371daa2069723886222b54416c76864b41b0b5ea1512f790334e0df86f7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2606a03735e547cea7846aba23","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp070629.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070633.exe","SHA1Sum":"790e933d6314b81f3e418b876622f3dd97610025","SHA256Sum":"25d65db0cc6894805b27650ea7c47f57727088125afc3cfdf14c8a8ae04219ca","SHA512Sum":"4da3450f2cd918c2a31510fca40b98991eb43c465bca1c055d427aabfe39bdbc8d436752233b075d0cb5b95c73a51f08fc5d5a0781522aa567ef5b26cf4b9e8a"}],"ComponentSizeInKB":2863,"CompsigList":["cp070633.compsig"],"FileList":["cp070629.compsig","cp070629.zip","cp070633.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070633.exe","SHA1Sum":"790e933d6314b81f3e418b876622f3dd97610025","SHA256Sum":"25d65db0cc6894805b27650ea7c47f57727088125afc3cfdf14c8a8ae04219ca","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ded7c7d2a2864118895c7e0c7a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072010.zip","SHA1Sum":"6fd9262a3be12cabcc0890161b43da07ce2f2dc6","SHA256Sum":"c91cba92e6e2d84e2fa9ec71a646ecccd4ea797d6353346d28a4dfc08856ef8c","SHA512Sum":"85c0b9d09943c3962ed4d60b50d140d9f0734701cded2bc9caf456439e0c95d7c30edefeeeb1dfa7597aa26469f2b653e92a23bb5a99d9ebb9788a76775c4f89"}],"ComponentSizeInKB":6371,"CompsigList":["cp072010.compsig"],"FileList":["/cp072010.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip","/sutComponent_800.6.8.0.14-0-signed_component.zip/index.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/vendor-index.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip","/sutComponent_800.6.8.0.14-0-signed_component.zip/vib20/sut/HPE_bootbank_sut_800.6.8.0.14-1OEM.802.0.0.22380479.vib","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip/vendor-index.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip/vmware.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip/vibs/sut-1795902474278544631.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip/bulletins/sutComponent_800.6.8.0.14-0.xml","/sutComponent_800.6.8.0.14-0-signed_component.zip/metadata.zip/configSchemas/sut-800.6.8.0.14-1OEM.802.0.0.22380479-schema.json"],"Name":"cp072010.zip","SHA1Sum":"6fd9262a3be12cabcc0890161b43da07ce2f2dc6","SHA256Sum":"c91cba92e6e2d84e2fa9ec71a646ecccd4ea797d6353346d28a4dfc08856ef8c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"TypeOfChange":"1","Version":"2026.07.00","VibList":[{"Name":"sut","Version":"800.6.8.0.14-1OEM.802.0.0.22380479"}]}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools 6.8.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":150,"RebootRequired":"yes","SWKeys":[{"Name":"sutComponent:800.6.8.0.14-0","SWKeyExpectedPath":"software.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1a618a71e88c40449553ef43f5","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","A42","U56","U61","U60","U64","U46","I43","I45","I44","I42","U65","U65","U58","U59","U57","U63","U62","U63","U58","U58","U54","U54","U54","U71","U69","U69","U71","U68","U72","U68","U68","HPE ProLiant DL380m Gen12","R13","U70","I46","U72","U77","H10","U65","H11","A58","U66","U68","A66","A66","U71","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware"},{"DelayAfterInstallSec":0,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","SHA1Sum":"12580bac8941a23f70f709b3471a42f1fbb6953d","SHA256Sum":"84554e850710f76c18ba689b4bbafc67cc1d0c20a5b45a3b731095a1f5c9a84e","SHA512Sum":"c57978a3a8b07a701375e1269e7f0a031e09a17f564aac57e35b6f8517865ac4b405f2ced27c00017c7c513f763be8d62b73e51dfb1a2ac3a9d379f7192a2b7a"}],"ComponentSizeInKB":6327,"CompsigList":["firmware-iegen10-0.2.3.0-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/CP068486.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068486.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068486.scexe"],"Name":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","SHA1Sum":"12580bac8941a23f70f709b3471a42f1fbb6953d","SHA256Sum":"84554e850710f76c18ba689b4bbafc67cc1d0c20a5b45a3b731095a1f5c9a84e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e91049f03c4649bd991453920d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U37","U38","U38","I43","I42","U45","U39","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070557.exe","SHA1Sum":"6b60d6b7863fe522587c662060dd9d2e5bf65abf","SHA256Sum":"4310ec32d9e863bffd82a6bf31a74f7dec16c9663e9edb2f5d5478459a7738ae","SHA512Sum":"2a407dbad7f1ba820559813c58d3e778eb9b3faddcad1847ce5a90ad7e6eddd635799baa305827fe7b86f6fc9850002fcb4cfa8fd77f5b3161f989a9d5ebe14a"}],"ComponentSizeInKB":1217,"CompsigList":["cp070557.compsig"],"FileList":["cp070557.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp070557.exe","SHA1Sum":"6b60d6b7863fe522587c662060dd9d2e5bf65abf","SHA256Sum":"4310ec32d9e863bffd82a6bf31a74f7dec16c9663e9edb2f5d5478459a7738ae","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.24.44.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d1cde8f10c9d4967b5cf6b5b44","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.rpm","SHA1Sum":"4d7cf2775b0a2bd4bacf111f7ffa18cedb145ee8","SHA256Sum":"955989f6aa1831ff275ff4f05236c2ab54e9d52b3c7415b4b07660c43b73c37b","SHA512Sum":"cf6222fe2ea3ac970ebba57d1e2d4068a7b311462a1688d9c961b62dc1a8bd431a9bf0160a631c598d6d274d77bfb772829233ef06c44b8927700b0369177fef"}],"ComponentSizeInKB":5309,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.rpm","SHA1Sum":"4d7cf2775b0a2bd4bacf111f7ffa18cedb145ee8","SHA256Sum":"955989f6aa1831ff275ff4f05236c2ab54e9d52b3c7415b4b07660c43b73c37b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 update 7 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22bda95782ad41e5a1e212825e","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U60_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U60_2.64_04_01_2026.fwpkg","SHA1Sum":"32e85b2513b1d16e17516414b41f408719fcb6c3","SHA256Sum":"d207139a034869dea2307cc8c24df1d1cc44c4b4d7143e68f57ed831eb5a85a1","SHA512Sum":"e2c2315e79309c9bfd34dca70cdb9ac1c0100d62e645de4bd897e9d04ddfb4d8ab8109350d9b9b3b8555d737e4ac549ac0ba34391b0cac9a756b1ac7c2a750c8"}],"ComponentSizeInKB":16422,"CompsigList":[],"FileList":["payload.json","U60_2.64_04_01_2026.signed.flash","U60_2.64_04_01_2026.xml"],"Name":"U60_2.64_04_01_2026.fwpkg","SHA1Sum":"32e85b2513b1d16e17516414b41f408719fcb6c3","SHA256Sum":"d207139a034869dea2307cc8c24df1d1cc44c4b4d7143e68f57ed831eb5a85a1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47a4d20c42f94a1b91b8ec0a69","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp068884.zip","SHA1Sum":"df8f7a216fdddf2310828b985e7e04a666a0e5df","SHA256Sum":"1a50c056539eea16ffb78dc3e37d40f75bf26f0f635ce9f0f531168b64b91cd3","SHA512Sum":"729c7934e9afa0f8f0166c22f8da1e9a1079469801464f924d4a3682de18cbcb0a11c85111c6eda373d0afcc9fae18e6584d6aa9aec3445694d16e0de0b03c18"}],"ComponentSizeInKB":238,"CompsigList":["cp068884.compsig"],"FileList":["/BCM_bootbank_lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip","/cp068884.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/metadata.zip","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/lsi-mr3-2214901657387861708.xml","/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.736.02.00-1OEM.800.1.0.20613240.xml"],"Name":"cp068884.zip","SHA1Sum":"df8f7a216fdddf2310828b985e7e04a666a0e5df","SHA256Sum":"1a50c056539eea16ffb78dc3e37d40f75bf26f0f635ce9f0f531168b64b91cd3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"lsi-mr3","Version":"7.736.02.00-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-lsi-mr3:7.736.02.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.736.02.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d76931c26af4d43986103fc1c","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U32","A43","A43","U61","A42","U60","U46","A43","A42","U65","U65","I46","U72","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070945.zip","SHA1Sum":"f3e3b0b1dc3aad00dcadb3c351f6fae01788b39a","SHA256Sum":"ee0a148f7082560093a469ab38b7a095b60f43b2e7f3498fc33635415add06f9","SHA512Sum":"55a6c5bf74474587712bd2011433fb45a97bb804142a1af1ea8f3269309887793ec14a21d6b99e83a596b74b6bbb8321e345887dc004aad4f2f1759aaf883aa5"}],"ComponentSizeInKB":19743,"CompsigList":["CP070945.compsig"],"FileList":["/CP070945_BUILD_5.data","/CP070945.vmexe64","/CP070945.vmfile","/CP070945_VMw.zip","/CP070945.xml","/payload.json","/CP070945_VMw.zip/index.xml","/CP070945_VMw.zip/vendor-index.xml","/CP070945_VMw.zip/metadata.zip","/CP070945_VMw.zip/vib20/CP070945/HPE_bootbank_CP070945_HPD8.5-8.0.0.20613240.vib","/CP070945_VMw.zip/metadata.zip/vendor-index.xml","/CP070945_VMw.zip/metadata.zip/vmware.xml","/CP070945_VMw.zip/metadata.zip/vibs/CP070945-3651765990428512566.xml","/CP070945_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070945_HPD8.5-8.0.0.20613240.xml"],"Name":"CP070945.zip","SHA1Sum":"f3e3b0b1dc3aad00dcadb3c351f6fae01788b39a","SHA256Sum":"ee0a148f7082560093a469ab38b7a095b60f43b2e7f3498fc33635415add06f9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070945","Version":"HPD8.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bce0494fcaa04ee8b04c057948","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","SHA1Sum":"37516b67c70e4d7b7b2a7de23a8b1d431da3cac2","SHA256Sum":"0f289e6023ec56dc97fdf3b086eb1ef5e2bebd0b3fd03c46c3a7a7996ac75502","SHA512Sum":"9f42c38c1912d171f1015124e2868dfb922518ba97b130a1e0ae8b16e1c0e00c799c5da849aeb1c62871e0cd526756385bd9b570f826037df1d687b3f79b27c9"}],"ComponentSizeInKB":5643,"CompsigList":["firmware-hdd-12304c1aca-HPG6-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/CP068937.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068937.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068937.scexe"],"Name":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","SHA1Sum":"37516b67c70e4d7b7b2a7de23a8b1d431da3cac2","SHA256Sum":"0f289e6023ec56dc97fdf3b086eb1ef5e2bebd0b3fd03c46c3a7a7996ac75502","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aeeaaa3ea8b3407f9705db0c96","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-2c27a7a9a4-HPD2-10.1.x86_64.rpm","SHA1Sum":"863a7b0ed617aa7239fbdf25e9a56823f9736085","SHA256Sum":"c4f293c342178bb600047e509a4758c53bd42d7c60795ea699bc4d9ec551d5e8","SHA512Sum":"3ca92ceb2e606e0a8fb5df10ca8c14ad2eeac329c40b284e3553bf5e84c65a7b52102b82ecfbeff5ab2469a996d3ea7c715ea86d7cc8e7d5883872fd03350223"}],"ComponentSizeInKB":6256,"CompsigList":["firmware-hdd-2c27a7a9a4-HPD2-10.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/CP068843.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068843.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068843.scexe"],"Name":"firmware-hdd-2c27a7a9a4-HPD2-10.1.x86_64.rpm","SHA1Sum":"863a7b0ed617aa7239fbdf25e9a56823f9736085","SHA256Sum":"c4f293c342178bb600047e509a4758c53bd42d7c60795ea699bc4d9ec551d5e8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_018279bc0bb148e6a910474b45","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U45_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u45-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"59b220b2fab3e3f5e2bb816b2b365a54b83f774d","SHA256Sum":"0f5ae0c14e127ac17f6f896724d7a81d724d7afe55df7e9a70cabe93303b1493","SHA512Sum":"36d285145fb2f306654ec519283ed5c2feaee9d1923d9c1608196a3e4ceac01be7ce334967376938bc5daf872f442f5318eff2c748d8b12d9151b93f67d531be"}],"ComponentSizeInKB":11334,"CompsigList":["firmware-system-u45-3.66_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/CP071454.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/U45_3.66_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.66_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071454.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071454.scexe"],"Name":"firmware-system-u45-3.66_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"59b220b2fab3e3f5e2bb816b2b365a54b83f774d","SHA256Sum":"0f5ae0c14e127ac17f6f896724d7a81d724d7afe55df7e9a70cabe93303b1493","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_33cf49ef52ff45b2a6203d8ffe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"a35f5bf969002e094272bc3133e66a33af4a2423","SHA256Sum":"c49aac23478d053ec768b4ed4dfbb4958ba88ddbd8a12670c0cbfbfc153b4d61","SHA512Sum":"3242a67bfb4cf844d696b4c3b602718a3a1630c0fcbd3bb4652270ba0b5f31b4e79cd1e18c29f965b4cc7d3778ec72c2adca5d6dec98eea966a1ca630d7ce049"}],"ComponentSizeInKB":839,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"a35f5bf969002e094272bc3133e66a33af4a2423","SHA256Sum":"c49aac23478d053ec768b4ed4dfbb4958ba88ddbd8a12670c0cbfbfc153b4d61","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Server Update 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f598604f92cb4cc68abc0f6807","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"237.1.148.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"BCM237.1.148.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"237.1.148.0"}]},"Files":[{"Checksum":[{"Filename":"BCM237.1.148.0_BCM957416A4162HC.fwpkg","SHA1Sum":"1a2b1a07436d4e5901c5a8835d867ac7b4159c2c","SHA256Sum":"0b609b3a171cb4ee32808c33e2b9210667eb57e7835f1a7cf8abba759be4b046","SHA512Sum":"5693250390195ae7ed0e4b3e468d66651a6c09095a1c7db83fef9b470dd070465e7f697a29d7cc95018a3405a4d0f06d442134d33d1b376549d72bcafbdf9dd5"}],"ComponentSizeInKB":1576,"CompsigList":[],"FileList":["BCM237.1.148.0_BCM957416A4162HC.HPb","BCM237.1.148.0_BCM957416A4162HC.xml","payload.json"],"Name":"BCM237.1.148.0_BCM957416A4162HC.fwpkg","SHA1Sum":"1a2b1a07436d4e5901c5a8835d867ac7b4159c2c","SHA256Sum":"0b609b3a171cb4ee32808c33e2b9210667eb57e7835f1a7cf8abba759be4b046","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593"],"TypeOfChange":"1","Version":"237.1.148.0"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107.0","Name":"Broadcom Firmware Package for BCM57416 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57416_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_257cf9350ff84feeac6deccbaa","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070985.zip","SHA1Sum":"51c1431e0aa81b8e75e923ac142d5925b007b39f","SHA256Sum":"f480a5fcc807bdd0fb47a28cf72b85b85634e4bc7ba52e640d849279d8c63872","SHA512Sum":"04e83c185fa096ffd3faee979b85e4c73547c3981eb1c095656dd8cdf0562d355c054557c8520fa2fa4cd3fa85d8afec541114ee6d217974170d5c5d67650e44"}],"ComponentSizeInKB":18408,"CompsigList":["CP070985.compsig"],"FileList":["/CP070985_BUILD_2.data","/CP070985.vmexe64","/CP070985.vmfile","/CP070985_VMw.zip","/CP070985.xml","/payload.json","/CP070985_VMw.zip/index.xml","/CP070985_VMw.zip/vendor-index.xml","/CP070985_VMw.zip/metadata.zip","/CP070985_VMw.zip/vib20/CP070985/HPE_bootbank_CP070985_HPD4.2-8.0.0.20613240.vib","/CP070985_VMw.zip/metadata.zip/vendor-index.xml","/CP070985_VMw.zip/metadata.zip/vmware.xml","/CP070985_VMw.zip/metadata.zip/vibs/CP070985--4096589684061340777.xml","/CP070985_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070985_HPD4.2-8.0.0.20613240.xml"],"Name":"CP070985.zip","SHA1Sum":"51c1431e0aa81b8e75e923ac142d5925b007b39f","SHA256Sum":"f480a5fcc807bdd0fb47a28cf72b85b85634e4bc7ba52e640d849279d8c63872","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070985","Version":"HPD4.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c2c06eb8c3ad475c83a108987b","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssacli-6.65-9.0_amd64.deb","SHA1Sum":"1ad12cb8f7fdfdd0495c7d34b6b6f2b5d4b57800","SHA256Sum":"20398bd1cb4c6b4852fcb9e1a5984b84c1550c5d5d50434a30069bc5c743470c","SHA512Sum":"f41cf281f5459d5413ff6388394d442aa345342d0da0f12f521f3d69a158eefc42d25eb066bb3a655351913908b30ec8187a15e6df3b29ddbb61c7ee37c393dc"}],"ComponentSizeInKB":10160,"CompsigList":["ssacli-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.65-9.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/doc/ssacli/changelog.Debian.gz","./usr/share/doc/ssacli/copyright","./usr/share/man/man8/ssacli.8.gz","./usr/share/smartupdate/ssacli/component.xml"],"Name":"ssacli-6.65-9.0_amd64.deb","SHA1Sum":"1ad12cb8f7fdfdd0495c7d34b6b6f2b5d4b57800","SHA256Sum":"20398bd1cb4c6b4852fcb9e1a5984b84c1550c5d5d50434a30069bc5c743470c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fe2051e194754709b11cd98e2f","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U63","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070980.zip","SHA1Sum":"cff9e1d4aafe4a1f7abd42db7e86a6377be48d48","SHA256Sum":"49e46b102ce09ef37867725f02d89940097a68a49f75cb0ea8a9c09d8985544c","SHA512Sum":"042d1af5ab606ff2a94c776681f9150eeccdc049ad54436ad4cfb7b518124394110f304a0e42a5ffafcdc226a2a2e13d6a7d4de913388b25e1039231ad6a37d9"}],"ComponentSizeInKB":19432,"CompsigList":["CP070980.compsig"],"FileList":["/CP070980_BUILD_1.data","/CP070980.vmexe64","/CP070980.vmfile","/CP070980_VMw.zip","/CP070980.xml","/payload.json","/CP070980_VMw.zip/index.xml","/CP070980_VMw.zip/vendor-index.xml","/CP070980_VMw.zip/metadata.zip","/CP070980_VMw.zip/vib20/CP070980/HPE_bootbank_CP070980_HPG1.1-8.0.0.20613240.vib","/CP070980_VMw.zip/metadata.zip/vendor-index.xml","/CP070980_VMw.zip/metadata.zip/vmware.xml","/CP070980_VMw.zip/metadata.zip/vibs/CP070980-8031440250491075634.xml","/CP070980_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070980_HPG1.1-8.0.0.20613240.xml"],"Name":"CP070980.zip","SHA1Sum":"cff9e1d4aafe4a1f7abd42db7e86a6377be48d48","SHA256Sum":"49e46b102ce09ef37867725f02d89940097a68a49f75cb0ea8a9c09d8985544c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070980","Version":"HPG1.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0bb9e1358c3844569b41cf17a7","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_UBM3_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"1.24"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM3_1.24_G.fwpkg","SHA1Sum":"050a05cd30e23620f120d6a3924f44b93cc84514","SHA256Sum":"55b03510c024198f628ac042d3a19bbcb847377ff5e6be951bd6b1e516eb36f7","SHA512Sum":"d55c8acfc9bc421504822115c02ca5f2b24ae1f1222e16065552ddeef2b586db1f5d1e59dcab0caf9b60f65ad7572abbcfaba0786a9e0b7ae742afa306f30a4d"}],"ComponentSizeInKB":62,"CompsigList":[],"FileList":["HPE_UBM3_1.24_G.HPb","HPE_UBM3_1.24_G.xml","payload.json"],"Name":"HPE_UBM3_1.24_G.fwpkg","SHA1Sum":"050a05cd30e23620f120d6a3924f44b93cc84514","SHA256Sum":"55b03510c024198f628ac042d3a19bbcb847377ff5e6be951bd6b1e516eb36f7","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901503000000"],"TypeOfChange":"1","Version":"1.24"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus and Gen11 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM3PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc8e3b1eb8804b47acb76ad46b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I45","A55","A55","A56","A56","U54","U54","U63","U58","U54","U63","U59","A42","U46","A42","U46","A43","A43","A43","U48","U50","A42","U61","U60","U46","U39","U71","U71","U68","U68","HPE ProLiant DL580 Gen12","U68"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_UBM1_1.50_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"1.50"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM1_1.50_A.fwpkg","SHA1Sum":"25235e69f55013ecca99054e57e8ec12719c5629","SHA256Sum":"69810eaea1b1355d050daeab076b444a93fe0a629039818a31a47b31186bbfbb","SHA512Sum":"84aa223276f360ee6150c8a48af26a4e672181c5d69df951c25dbab82c3bc7fce3b1161077a7d0a78e86a00c3ed0b518ad90dc124bdc07bc2896a0f454f3225b"}],"ComponentSizeInKB":59,"CompsigList":[],"FileList":["HPE_UBM1_1.50_A.HPb","HPE_UBM1_1.50_A.xml","payload.json"],"Name":"HPE_UBM1_1.50_A.fwpkg","SHA1Sum":"25235e69f55013ecca99054e57e8ec12719c5629","SHA256Sum":"69810eaea1b1355d050daeab076b444a93fe0a629039818a31a47b31186bbfbb","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901501000000"],"TypeOfChange":"1","Version":"1.50"}],"InstallationDependency":{},"Name":"Firmware Package - UBM1 Backplane PIC PLDM Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM1PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3e1ab84fc2974d1e836855d8d4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","12.0","7.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A43","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","HPE Apollo 2000 Gen10 Plus System","I44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","SHA1Sum":"23a48311e02dd55e4e81e78baeda38cef4aacbc7","SHA256Sum":"06c0a19d1abcc106cc8ef5a8301f16a0c89a70b569db53d309e1d158293c449d","SHA512Sum":"4333f33fe66a9d028b3f278e5766919a2c5abbdf05f651e91d9a265ff4d241d841b391a784380f76a21e32bc29e14ff3493bcd7414da84c1ae096cd4c46ff8e0"}],"ComponentSizeInKB":4414,"CompsigList":["firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/CP068905.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068905.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068905.scexe"],"Name":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","SHA1Sum":"23a48311e02dd55e4e81e78baeda38cef4aacbc7","SHA256Sum":"06c0a19d1abcc106cc8ef5a8301f16a0c89a70b569db53d309e1d158293c449d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_89e45fac4c3a461283ecd1b976","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"CP070903.zip","SHA1Sum":"5ca9a82fac8c080b82933a6b81aec789db31a342","SHA256Sum":"2801f534d4c00238958861bc0e0be21888de589b8426a0f708d8d73aef8e4529","SHA512Sum":"85852ed17c596b9c708f4ce2c5fdb22cdad0dace8aa1883439d21377cba9c12d80bf60d4cb4be4c2ab7285c330d1f836e070fb306158bf6a217dfb5140d63fed"}],"ComponentSizeInKB":22053,"CompsigList":["CP070903.compsig"],"FileList":["/CP070903_BUILD_3.data","/CP070903.vmexe64","/CP070903.vmfile","/CP070903_VMw.zip","/CP070903.xml","/payload.json","/CP070903_VMw.zip/index.xml","/CP070903_VMw.zip/vendor-index.xml","/CP070903_VMw.zip/metadata.zip","/CP070903_VMw.zip/vib20/CP070903/HPE_bootbank_CP070903_HPK4.3-8.0.0.20613240.vib","/CP070903_VMw.zip/metadata.zip/vendor-index.xml","/CP070903_VMw.zip/metadata.zip/vmware.xml","/CP070903_VMw.zip/metadata.zip/vibs/CP070903-560840138915920864.xml","/CP070903_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070903_HPK4.3-8.0.0.20613240.xml"],"Name":"CP070903.zip","SHA1Sum":"5ca9a82fac8c080b82933a6b81aec789db31a342","SHA256Sum":"2801f534d4c00238958861bc0e0be21888de589b8426a0f708d8d73aef8e4529","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4","VibList":[{"Name":"CP070903","Version":"HPK4.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_affe92f0e28d408f95167ca9fa","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","SHA1Sum":"8a1e2dcabe269dc301216be9324894bbe27f4279","SHA256Sum":"ec0826bea4e3419cb64cbd652f0985a5ef997549e0ffc8210c5b12a007011182","SHA512Sum":"3c972c69e9bd50e22532dc7dd0ddb6ad49e5c6ae129aae861bb8962a071909ab37779243362a6c41008862f13eb92a2cfd765d1db47ea5e3cd64fef0d9364e6e"}],"ComponentSizeInKB":6383,"CompsigList":["firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/CP068848.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068848.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068848.scexe"],"Name":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","SHA1Sum":"8a1e2dcabe269dc301216be9324894bbe27f4279","SHA256Sum":"ec0826bea4e3419cb64cbd652f0985a5ef997549e0ffc8210c5b12a007011182","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26783d282a644af9b665b99090","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Files":[{"Checksum":[{"Filename":"cp069564.exe","SHA1Sum":"4ca6b16424201e083799e99ff472dab17685621b","SHA256Sum":"79d1ff0171005901d4547aaa06b78758829d9f6448cc8a49537b819c403621e5","SHA512Sum":"4b3031622e4c4670a549d62605eeff4f92da39f7f7c16a39bbe5cd45965f113e94d9999fff3dbf516a91f5a3acf54b178bef183f33281df32d7b30370979b588"}],"ComponentSizeInKB":3062,"CompsigList":["cp069564.compsig"],"FileList":["cp069564.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.65.23.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069564.exe","SHA1Sum":"4ca6b16424201e083799e99ff472dab17685621b","SHA256Sum":"79d1ff0171005901d4547aaa06b78758829d9f6448cc8a49537b819c403621e5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"5.3.7.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_100ccd3730bb453988f65d8a8d","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.deb","SHA1Sum":"f8ef8d0437dab03c97900eba03bf3d3a4a0c1b82","SHA256Sum":"26daca030e03ef9d96ae473d66679cc3984011539d5e128a97c24f9b12ed07b5","SHA512Sum":"b4b54fed361e3055c4fdf0881a37cd951e07c1efb5fe89fad519acafbe700a8a123c1a837a14f06139d68abdb125c780811acba9f4db2f69cffa1e835d61d971"}],"ComponentSizeInKB":3703,"CompsigList":["firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/CP071756.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071756.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071756.scexe"],"Name":"firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.deb","SHA1Sum":"f8ef8d0437dab03c97900eba03bf3d3a4a0c1b82","SHA256Sum":"26daca030e03ef9d96ae473d66679cc3984011539d5e128a97c24f9b12ed07b5","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_034911c8b13c45c3bf533add81","SupportedDevices":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.66 (04/01/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U34_3.66_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.66 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"U34_3.66_04_01_2026.fwpkg","SHA1Sum":"6017c65a49b6fe407e7cc40e5fc096bf849fb502","SHA256Sum":"3b317e43482f3bd530b350bde615e709fc65d680c69e6da34baf6a0d708b5be3","SHA512Sum":"868abeca4e5775b9bdb08913007ac08c254c32b7f8a02b5a8b4798aa6631616d69f7f4d999397e215ab160ef5eada972cab9bf9d7d56d1202543964ab9c672a7"}],"ComponentSizeInKB":32826,"CompsigList":[],"FileList":["payload.json","U34_3.66_04_01_2026.signed.flash","U34_3.66_04_01_2026.xml"],"Name":"U34_3.66_04_01_2026.fwpkg","SHA1Sum":"6017c65a49b6fe407e7cc40e5fc096bf849fb502","SHA256Sum":"3b317e43482f3bd530b350bde615e709fc65d680c69e6da34baf6a0d708b5be3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.66_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a689bdc152a74bc29443bd8885","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.rpm","SHA1Sum":"322c3162f95b8f23e5cc5f517fd8c1d715d90a38","SHA256Sum":"9cfefe6ec509602a3db61125d3d49360ef59d2e3d6db4385b7a5e661e12a841a","SHA512Sum":"aa3de9e0a0fdfa6dcde8c540922623007a83b02bf0cdbd723dbb6a2c844ed6c73477a2b5104b34ba2cdad33569ae9cc636725fb74d3c9773a0137e70b4ef3bee"}],"ComponentSizeInKB":114,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/224b178390684ba55b948b52b191f226e31983","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.rpm","SHA1Sum":"322c3162f95b8f23e5cc5f517fd8c1d715d90a38","SHA256Sum":"9cfefe6ec509602a3db61125d3d49360ef59d2e3d6db4385b7a5e661e12a841a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.rpm","SHA1Sum":"bf45cd1885afa9aca388e5166428926af40c4dd2","SHA256Sum":"f33eaba79a855417d483f5e271cca76f1ffb26ade01f1e8fba4799992a9cb42b","SHA512Sum":"3b8109297fdc68f610e975fe1cb4d10d3b9cb6145dd6b38f1888434b3418192affc06a875279d1bce56c0e2bcc3911f3fbfe1267f23bf5d848ae51b909a1f79a"}],"ComponentSizeInKB":113,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/smartpqi","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/72","./usr/lib/.build-id/72/35b83af3187dfd926218b08de0de4926a4bb8a","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.rpm","SHA1Sum":"bf45cd1885afa9aca388e5166428926af40c4dd2","SHA256Sum":"f33eaba79a855417d483f5e271cca76f1ffb26ade01f1e8fba4799992a9cb42b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 10 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3806afac3ba849ffa40bccc9bf","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","HPE Apollo 2000 Gen10 Plus System","A42","U46","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","A43","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200 1p OSFP MCX75310AAS Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","InstallDurationSec":900,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30074","Version":"28.49.1014"}]},"Files":[{"Checksum":[{"Filename":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","SHA1Sum":"f181907f5cc590d807edeff2d516a1bb08b15ea4","SHA256Sum":"290b0dc84801ab9b092c2e51756a0795046128344d57c1220daa67a0a11ccedd","SHA512Sum":"2441a1f469338ef4894f7b68c7409e4c503872ab81d32277c10b5eaaf506d8945501799db3c4d7ae241f4e72c9729be04f0995f0fb255e8237d2c8356189dace"}],"ComponentSizeInKB":9412,"CompsigList":[],"FileList":["28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.xml","payload.json"],"Name":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","SHA1Sum":"f181907f5cc590d807edeff2d516a1bb08b15ea4","SHA256Sum":"290b0dc84801ab9b092c2e51756a0795046128344d57c1220daa67a0a11ccedd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30074"],"TypeOfChange":"1","Version":"28.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":900,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d81d839f3a64f16a96d99e796","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30074"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3830-304b584e5848","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3630-304b584e5a56","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3230-304b58504141","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3630-3430-304b58504142","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-304b584e5844","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-304b584e5a51","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-304b584e5a52","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3730-3638-304b584e5a54","Version":"HPS7"}]},"Files":[{"Checksum":[{"Filename":"Micron_7450U3_M7450ALLHPS7.fwpkg","SHA1Sum":"4115c487768ac445063716b2c07d2dee18e7866b","SHA256Sum":"a872871f8f522469a1dcb30a0dc2c905bcbc1450ce2d7691a43a0d965ff58849","SHA512Sum":"f401ac836e8542559ffb704df0753a90d08bce5cd04ee6cfe42a191f83c8a2ca79d427cae6a2e3f0312d8aadc6f73d285fa2d3af6193e4c8e1c56aed9f82a6a6"}],"ComponentSizeInKB":2337,"CompsigList":[],"FileList":["Micron_7450U3_M7450ALLHPS7.HPb","Micron_7450U3_M7450ALLHPS7.xml","payload.json"],"Name":"Micron_7450U3_M7450ALLHPS7.fwpkg","SHA1Sum":"4115c487768ac445063716b2c07d2dee18e7866b","SHA256Sum":"a872871f8f522469a1dcb30a0dc2c905bcbc1450ce2d7691a43a0d965ff58849","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844","562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54"],"TypeOfChange":"1","Version":"HPS7"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXNXD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXNZQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXNZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXNZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO000800KXNXH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXNZV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPAA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPAB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21dbae1890804e0a855212de38","SupportedDevices":["562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54","4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0","7.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"4cdb0affacd98bee3fd9493d5e1b0e9eefbfb8d1","SHA256Sum":"175e26930057a7345bf3b14f5a25070045e2c8170565d8140324b82c9983dffb","SHA512Sum":"31006bb31e0b12b10364dbef069e1e79b0a6ccdc890726b99013c18924df950cbe247645a7524854d4c60f0cb193cf616a23dc3055345aa6ebceb8f959f1968a"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","SC_DL20GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"4cdb0affacd98bee3fd9493d5e1b0e9eefbfb8d1","SHA256Sum":"175e26930057a7345bf3b14f5a25070045e2c8170565d8140324b82c9983dffb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b80ea0c364894c39803e12217a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071328.exe","SHA1Sum":"2ee21311f2d190b4169d9daa1d7e13f575eccf41","SHA256Sum":"70656f64e759ccfaa76f55ba9b8a5a79c51b4b5dfbfb596b754507d103a11c24","SHA512Sum":"fc8902939c25bce8ca8e04798c47047110706b1140a65a38382664c18098849dd0dc472e6fc92b5ea18e995f6e3c4dd5643466ba652d101685e3a2c67fa1c4c5"}],"ComponentSizeInKB":1095,"CompsigList":["cp071328.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp071328.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071328.exe","SHA1Sum":"2ee21311f2d190b4169d9daa1d7e13f575eccf41","SHA256Sum":"70656f64e759ccfaa76f55ba9b8a5a79c51b4b5dfbfb596b754507d103a11c24","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"237.1.124.0"}],"InstallationDependency":{},"Name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e02971f440944b8296e274f254","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-181914e41760","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14E4-180800000000","a6b1a447-382a-5a4f-14E4-181B00000000","a6b1a447-382a-5a4f-14E4-180900000000","a6b1a447-382a-5a4f-14E4-181B00000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","H10","H10","H10","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3230-3030-304759444e4b","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-304759445044","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","SHA1Sum":"92e09fe04033bc134c66afaad9fb56d6ec9d690a","SHA256Sum":"fb3716a3647cab1b6e97139a51176141599ca2a43a06efdabed395bc19313127","SHA512Sum":"bb6a5a7fba35c2879c1a257577dc4a7f557d6cafe23937ec615d36c8d4516aafdca3c6ceb9de33d0f3830003c77091cd725a7a4601b133ab4fb62f048a994409"}],"ComponentSizeInKB":2560,"CompsigList":[],"FileList":["payload.json","Seagate_CimarronBP_SCIMARBPNTG4.HPb","Seagate_CimarronBP_SCIMARBPNTG4.xml"],"Name":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","SHA1Sum":"92e09fe04033bc134c66afaad9fb56d6ec9d690a","SHA256Sum":"fb3716a3647cab1b6e97139a51176141599ca2a43a06efdabed395bc19313127","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000GYDNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB004000GYDPD","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_598a471de19b4292a91b0bdd45","SupportedDevices":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068656.exe","SHA1Sum":"b8b3bd831761906cd1ebb330c47d4948f56331d2","SHA256Sum":"0e778a085ea22546d937519806556fa9b9ecefae2eaa48d8c924e428aada2021","SHA512Sum":"b2c276a44228fbe0a6e90799dab313ef0580ec566da670b2d09e67661ce58dfb615454fc4346f36b521ada4875dd1844b51381885a24780553f8abd8d5f9e936"}],"ComponentSizeInKB":3935,"CompsigList":["cp068656.compsig"],"FileList":["cp068656.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTNDB.rel"],"Name":"cp068656.exe","SHA1Sum":"b8b3bd831761906cd1ebb330c47d4948f56331d2","SHA256Sum":"0e778a085ea22546d937519806556fa9b9ecefae2eaa48d8c924e428aada2021","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_06611b50fde44566a65773be61","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-igb-5.19.10-1.rhel9u7.x86_64.rpm","SHA1Sum":"a2c984ab741f99621c03853e2f70148fdd0d65ab","SHA256Sum":"fded8fea5b521ab7b72e5b1b4df13ec8a71821d3bd5e67f5769c254384179ad0","SHA512Sum":"93ec7a93844072f3feccf2d3570eea2b43e682e06cfdf25576d137ac0e0c2f17022d99a9bb04f8755bc07d933e9aab94a7c1e90635e22664b134987c5c341859"}],"ComponentSizeInKB":184,"CompsigList":["kmod-hp-igb-5.19.10-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-igb","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/59","./usr/lib/.build-id/59/544c233ae07fe7cad27b19421384b6c06c3104","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"Name":"kmod-hp-igb-5.19.10-1.rhel9u7.x86_64.rpm","SHA1Sum":"a2c984ab741f99621c03853e2f70148fdd0d65ab","SHA256Sum":"fded8fea5b521ab7b72e5b1b4df13ec8a71821d3bd5e67f5769c254384179ad0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.19.10-1"},{"Checksum":[{"Filename":"kmod-hp-igb-5.19.10-1.rhel9u6.x86_64.rpm","SHA1Sum":"1361cca0ea696ad0407417fba73f1119bfb2e4d0","SHA256Sum":"ad33ada2aa77f73630dce7685d504aa07743df7085a5c97a9ed31df2413e5d52","SHA512Sum":"8753a1e64d3270578953a9c42fa6785d67cd425ff4baf2a098633bf7a742cf4a119966d01da568495db33afb01a37127ea4f83ad7417583aaec472ad69264765"}],"ComponentSizeInKB":179,"CompsigList":["kmod-hp-igb-5.19.10-1.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-igb","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/28","./usr/lib/.build-id/28/515e4db6d7a1c2ef4561550438a5840dab28a0","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"Name":"kmod-hp-igb-5.19.10-1.rhel9u6.x86_64.rpm","SHA1Sum":"1361cca0ea696ad0407417fba73f1119bfb2e4d0","SHA256Sum":"ad33ada2aa77f73630dce7685d504aa07743df7085a5c97a9ed31df2413e5d52","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.19.10-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b262cfae6ec543a2aceb25b000","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071589.exe","SHA1Sum":"3769074f2537137af88ef70529e66336ee348d6d","SHA256Sum":"ba831c4fd9c2c6d0bb840b521718f4a6d8525151ef40e099eb50796fff788d00","SHA512Sum":"b6879a7f362d7d9823e3169883e0ee7bf1ca08f7aff6e10853f7bda098515d6f4a2b756f3aa738a8d9f2c099013cf729c6f0ecd37fcaaf86ed99eee200e9e657"}],"ComponentSizeInKB":958,"CompsigList":["cp071589.compsig"],"FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp071589.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071589.exe","SHA1Sum":"3769074f2537137af88ef70529e66336ee348d6d","SHA256Sum":"ba831c4fd9c2c6d0bb840b521718f4a6d8525151ef40e099eb50796fff788d00","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.10.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a7d1b02525a54541b5c62e7367","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U37","U38","U38","O43","U40","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","U66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"U61_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u61-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"a993482fc38cb4b8a7d53aa5367bce0b079532af","SHA256Sum":"7bc43d4e3fd7832e29a42f33fb66b97593d501a30f5b356acaca8c6e385d0245","SHA512Sum":"e7d01a1aa922692117204c40ab472add2c01457ffbdb8bbee733b10d0b04fd193d5f7676b8c14a6acc8bc31d504bf20301aebfcd2d1b9c8ae5e0be18244c5d14"}],"ComponentSizeInKB":16760,"CompsigList":["firmware-system-u61-2.64_2026_04_01-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/CP071340.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/U61_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071340.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071340.scexe"],"Name":"firmware-system-u61-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"a993482fc38cb4b8a7d53aa5367bce0b079532af","SHA256Sum":"7bc43d4e3fd7832e29a42f33fb66b97593d501a30f5b356acaca8c6e385d0245","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c8751ce621234e80adfa93ede5","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"H10_2.64_04_01_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.64 (04/01/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-h10-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"32c3e3f167da0839db1c1e646ec1f8ffa4a5ae60","SHA256Sum":"70a16f9a98a32fe60fe684274583e9f9f7f8726357b0f64d73f6617ce541471f","SHA512Sum":"7f60e6038b8b4cc0b1dbb04c171001c6e2e97440da5a0cfc7b4990064fcf17fe728048a1481abbbcab60a386c78ff19836e7be7fb55895b6d3d092d31e67e052"}],"ComponentSizeInKB":33206,"CompsigList":["firmware-system-h10-2.64_2026_04_01-1.1.x86_64_part1.compsig","firmware-system-h10-2.64_2026_04_01-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/CP071459.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/H10_2.64_04_01_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.64_2026_04_01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071459.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071459.scexe"],"Name":"firmware-system-h10-2.64_2026_04_01-1.1.x86_64.rpm","SHA1Sum":"32c3e3f167da0839db1c1e646ec1f8ffa4a5ae60","SHA256Sum":"70a16f9a98a32fe60fe684274583e9f9f7f8726357b0f64d73f6617ce541471f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"1","Version":"2.64_04-01-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_50817eec0bf441a4b060aed22c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","8.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","H10","FTP","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3030-3936-3052584b5243","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3130-3932-3052584b5248","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"4d2340a5-304f-3330-3834-3052584b524b","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3030-3936-3052584b5242","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3130-3932-3052584b5244","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"562340a5-304f-3330-3834-3052584b5245","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","SHA512Sum":"db0e960bdae7cc10b6ea8e0eb29886f098e4728aba77e1f130441a8dfc4b66347a686cb728d4bfc8b729c7b39f05338bb4fe6e009301e91d28c2f0f3646ececd"}],"ComponentSizeInKB":2120,"CompsigList":[],"FileList":["payload.json","Seagate_LangeBP_SLNGBPHPESD5.HPb","Seagate_LangeBP_SLNGBPHPESD5.xml"],"Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000960RXKRC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXKRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXKRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXKRB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXKRD","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXKRE","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_698b806535e54899a0d8cfa4fa","SupportedDevices":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3911.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3911.0"}]},"Files":[{"Checksum":[{"Filename":"cp070389.exe","SHA1Sum":"f2f6b50b4eaee249e644f0bbe94c1dace2e8a4ed","SHA256Sum":"2b17e870a3d358258f0b47d7988b4b6021c81ef49f0aad5adeafd6a50fcef9ca","SHA512Sum":"ab1781a4828d0642d5cbc69d929e66631f19b75767d097b569e1286dacf34d4bcb8be7e3c236acd0021c675b0f789d910592480520ab1f998008cf95a9fef2a2"}],"ComponentSizeInKB":12421,"CompsigList":["cp070389.compsig"],"FileList":["cp070389.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_366FLR_G41713-00x_800011A1.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_800011F1.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","FW/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","FW/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","FW/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp070389.exe","SHA1Sum":"f2f6b50b4eaee249e644f0bbe94c1dace2e8a4ed","SHA256Sum":"2b17e870a3d358258f0b47d7988b4b6021c81ef49f0aad5adeafd6a50fcef9ca","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"5.4.8.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2ad5c8103a0241779549820409","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware"}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068743.exe","SHA1Sum":"5706431b5ba5e66c325d8446d19096f3f84be2c6","SHA256Sum":"5e9e6a8954600e81584dfb560f604b9170921977cb8d1b039151c2ab21f34cfb","SHA512Sum":"bfbf54404dc193424d6f11b6e6cc2a76be3f04cb4566767d44439ba5d173f765e727ae36f7e12c285ac8369b43d06f0b08b595d2b8dd817338ed213a168f71c5"}],"ComponentSizeInKB":4411,"CompsigList":["cp068743.compsig"],"FileList":["cp068743.xml","cpqsetup.exe","HVLAnAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068743.exe","SHA1Sum":"5706431b5ba5e66c325d8446d19096f3f84be2c6","SHA256Sum":"5e9e6a8954600e81584dfb560f604b9170921977cb8d1b039151c2ab21f34cfb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_98e732bf3fe24672901b485ba2","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware"}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"CP072199.zip","SHA1Sum":"c57f6a5f27a1bd2094681cf7caa1d963d32012dd","SHA256Sum":"2499dad9aac868cfc1d7a830e7c95cdedbcaf10796ccffdaf1037eadcfae6917","SHA512Sum":"7e3ef9c0dd715eecdf8d915e6b466a080efb21044c38437b6f2576a3b54237bb1a91d815365b537cdd2d057bbd6b64744652519ff76bb265f3976c6d18a0e8d6"}],"ComponentSizeInKB":8151,"CompsigList":["CP072199.compsig"],"FileList":["/CP072199_BUILD_1.data","/CP072199.vmcfg","/CP072199.vmexe64","/CP072199.vmfile","/CP072199_VMw.zip","/CP072199.xml","/payload.json","/CP072199_VMw.zip/index.xml","/CP072199_VMw.zip/vendor-index.xml","/CP072199_VMw.zip/metadata.zip","/CP072199_VMw.zip/vib20/CP072199/HPE_bootbank_CP072199_5.04.1-8.0.0.20613240.vib","/CP072199_VMw.zip/metadata.zip/vendor-index.xml","/CP072199_VMw.zip/metadata.zip/vmware.xml","/CP072199_VMw.zip/metadata.zip/vibs/CP072199-8439978499155422694.xml","/CP072199_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072199_5.04.1-8.0.0.20613240.xml"],"Name":"CP072199.zip","SHA1Sum":"c57f6a5f27a1bd2094681cf7caa1d963d32012dd","SHA256Sum":"2499dad9aac868cfc1d7a830e7c95cdedbcaf10796ccffdaf1037eadcfae6917","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04","VibList":[{"Name":"CP072199","Version":"5.04.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58fe379fbd0f4e37a3ac67cb3e","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"FileName":"HPE_E810_XXVDA4_FH_4p91_PLDMoMCTP_800214B3.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"Type":"Firmware"}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.91"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA4_FH_4p91_PLDMoMCTP_800214B3.fwpkg","SHA1Sum":"fa0d419202702d8911ea89cd633f986b6a4563d2","SHA256Sum":"9c1549dbc8d6041c1836eeeea8e91eef9e742353af8a80cccc8588db17ab9f67","SHA512Sum":"6d0b903821818a06fff52b0b5031c68270aba4617227fb67f28bb8be59747cee1bb2459ab23036c8c7d1e3b845a32ab0c4cf9fb967692fccc292ca94b418e38c"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA4_FH_4p91_PLDMoMCTP_800214B3.HPb","HPE_E810_XXVDA4_FH_4p91_PLDMoMCTP_800214B3.xml","payload.json"],"Name":"HPE_E810_XXVDA4_FH_4p91_PLDMoMCTP_800214B3.fwpkg","SHA1Sum":"fa0d419202702d8911ea89cd633f986b6a4563d2","SHA256Sum":"9c1549dbc8d6041c1836eeeea8e91eef9e742353af8a80cccc8588db17ab9f67","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.91"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_081aedd3c74d4f6ba6a7d66111","SupportedDevices":["a6b1a447-382a-5a4f-8086-159380860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm","SHA1Sum":"1cfd581994855b658202ca407af13e4bc2a4d74b","SHA256Sum":"aebe53ecd2781f4e5b142b5dde500a2543babaa1488058d7bbf14f3735af97ce","SHA512Sum":"404284079de4d2b25d0a313d8e76268da0607bee59c35f3e5df84a02150bb2b5495880e84ab6ec9798599b51f80484d70756333b66d8d2d7159221b146fee918"}],"ComponentSizeInKB":54,"CompsigList":["libbnxt_re-237.1.137.0-sles15sp7.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-237.1.137.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm","SHA1Sum":"1cfd581994855b658202ca407af13e4bc2a4d74b","SHA256Sum":"aebe53ecd2781f4e5b142b5dde500a2543babaa1488058d7bbf14f3735af97ce","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"237.1.137.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_91039c6051484f4fac7a0051e3","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]}],"Prerequisites":[{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-98373e8f27_5.61-2.1_amd64.deb","SHA1Sum":"fcfec0e7b9d79128ff8801acf6635af144757f10","SHA256Sum":"01ca58b6515c7ba1e4441fda0b621d0626a73fff371407f362bb8f73c98a18de","SHA512Sum":"4f433a6ab0b5c2d1cbba51805f26a95e836d470af1bb2c9940262507b9f5bdb1ee2c254efaacb4a404585be5dad670042e300e201537efe6aa2dcb939913f3bc"}],"ComponentSizeInKB":7128,"CompsigList":["firmware-smartarray-98373e8f27_5.61-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/CP071922.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071922.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071922.scexe"],"Name":"firmware-smartarray-98373e8f27_5.61-2.1_amd64.deb","SHA1Sum":"fcfec0e7b9d79128ff8801acf6635af144757f10","SHA256Sum":"01ca58b6515c7ba1e4441fda0b621d0626a73fff371407f362bb8f73c98a18de","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_87846028abe441eea8ec94c423","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","U46","U30","U46","U32","A43","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","U39","I43","I45","I44","I42","U54","U54","U54","U61","U60","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"CP070640.zip","SHA1Sum":"8fa176fceee4d489ee16e5f4fcdccccaa7a92097","SHA256Sum":"e7ca1e0217d174df2148da8642cb62015fac674f0b023bb39f08bc47af411057","SHA512Sum":"2fa712613181e3909872e08922774227671df04c8c3a12482d62af8ca5b1cfc744a0f3faf3eeabb6161406293cc70159d456b5f93daf6983a71ebfa8a70c3016"}],"ComponentSizeInKB":15290,"CompsigList":["CP070640.compsig"],"FileList":["/CP070640_BUILD_3.data","/CP070640.vmexe64","/CP070640.vmfile","/CP070640_VMw.zip","/CP070640.xml","/payload.json","/CP070640_VMw.zip/index.xml","/CP070640_VMw.zip/vendor-index.xml","/CP070640_VMw.zip/metadata.zip","/CP070640_VMw.zip/vib20/CP070640/HPE_bootbank_CP070640_226.1.107000.3-8.0.0.20613240.vib","/CP070640_VMw.zip/metadata.zip/vendor-index.xml","/CP070640_VMw.zip/metadata.zip/vmware.xml","/CP070640_VMw.zip/metadata.zip/vibs/CP070640--4426234129328520795.xml","/CP070640_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070640_226.1.107000.3-8.0.0.20613240.xml"],"Name":"CP070640.zip","SHA1Sum":"8fa176fceee4d489ee16e5f4fcdccccaa7a92097","SHA256Sum":"e7ca1e0217d174df2148da8642cb62015fac674f0b023bb39f08bc47af411057","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000","VibList":[{"Name":"CP070640","Version":"226.1.107000.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3267d053777342b39e46243b6e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U39","U64","A40","A41","O43"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM957504 100G 1P QSFP56 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E45100","Version":"226.1.107.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-bcm-nxe-226.1.107.0-2.1.x86_64.rpm","SHA1Sum":"d747df79fc9050fa5f002334b73a4d21cdcd4358","SHA256Sum":"5d0c0f9a58e5f558b7c8ee141d29d306f8396352c5fae26b9f4f74ffc6c40f62","SHA512Sum":"e6e88e9358ab5fcece03143ffceaac43ff3584ae7c1f27ca6d179b1508a6e28f7ec1e52e4b6325e44598a7de9d2b99d546a45fd2a9755aa1d7d0253903da1178"}],"ComponentSizeInKB":9220,"CompsigList":["firmware-nic-is-bcm-nxe-226.1.107.0-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412A4121HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412N4120HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414A4142HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414N4140HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416A4162HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416N4160HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504A504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504N504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063802.scexe"],"Name":"firmware-nic-is-bcm-nxe-226.1.107.0-2.1.x86_64.rpm","SHA1Sum":"d747df79fc9050fa5f002334b73a4d21cdcd4358","SHA256Sum":"5d0c0f9a58e5f558b7c8ee141d29d306f8396352c5fae26b9f4f74ffc6c40f62","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599","a6b1a447-382a-5a4f-14E4-175114E45100"],"TypeOfChange":"1","Version":"226.1.107.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0fe8c4c618054fe0bf5f8d2fd3","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-175114e45100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U30","U32","U43","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U46","U65","U65","U65","U70","U71","U69","U71","U69","U58"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"firmware-9041739931_1.2.14.1018-1.1_amd64.deb","SHA1Sum":"6f6698485f32f31fb46d6f77a5d55ec32c42ec81","SHA256Sum":"cfdba5e3cdf3d44a140382100141d4ed7b7818665d223897465e7d38357788b4","SHA512Sum":"3266da7a1476053135037b3037a999fbee3e59d281d7c2f6f640ce7a3bc6e0b85081a46fa902138635d07e178cb95b95423f085816fb79febd696a44dbc2eaf8"}],"ComponentSizeInKB":764,"CompsigList":["firmware-9041739931_1.2.14.1018-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/CP067804.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067804.scexe","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067804.scexe"],"Name":"firmware-9041739931_1.2.14.1018-1.1_amd64.deb","SHA1Sum":"6f6698485f32f31fb46d6f77a5d55ec32c42ec81","SHA256Sum":"cfdba5e3cdf3d44a140382100141d4ed7b7818665d223897465e7d38357788b4","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Ubuntu - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7745ced637364082a3707b93a7","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I44","U46","A42","U34","U34","A42","U46","U30","U32","A43","A43","A43","U43","U41","U33","U44","A47","A48","U47","A46","U47","U48","U40","U50","U39","A42","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_148.bin","InstallDurationSec":150,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"firmware-ilo5-1.48-3.1.x86_64.rpm","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","SHA512Sum":"a8176ccbb28b4b45c781a1cb568e772ffb35e71b4a1fbe3b728afe8d311ea478a52ec21f6b83fbb300d835925ed794c6ab77234090050de41e700b6386c970bd"}],"ComponentSizeInKB":17058,"CompsigList":["firmware-ilo5-1.48-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/CP064211.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/ilo5_148.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064211.scexe"],"Name":"firmware-ilo5-1.48-3.1.x86_64.rpm","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":150,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_705315077b1e4ba986471688e7","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","6.0","6.0","6.0","7.0","11.0","11.0","12.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","A42","U46","U46","A43","A45","U51","U47","A46","U47","U47","U47","U50","I44"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.fwpkg","SHA1Sum":"6b7e92433f5befb184c38a3242a3952589f829f7","SHA256Sum":"7f10e350c6a49e2c35438568d9c725019f956d0fc9bc90061900a23e4ee43e12","SHA512Sum":"d820ef1dec96b9522d83da9208d0b5cd6af1cd363649db34e839db3a29d22bd9c4abcb256cce7cbec65951082afdaae4fb1950a9ec081f0b45b738d5ce673a96"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.fwpkg","SHA1Sum":"6b7e92433f5befb184c38a3242a3952589f829f7","SHA256Sum":"7f10e350c6a49e2c35438568d9c725019f956d0fc9bc90061900a23e4ee43e12","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8dec9b5d239f4e5ca376e1076e","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860003"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"CP070871.zip","SHA1Sum":"5cfdd0fe420cb5d367cec7836269095162439008","SHA256Sum":"9ecd22a5b03d8c5cc9c7f23d63ed1250a3aed12fd9dc7c4d9bb37931fb491993","SHA512Sum":"fa70b52be472f2a700b3bc9f9c4c3d3fe6c823b911c997b5ee6dde0a7f65081d2164607aad2ccbad490f51297830c257d178fa7773fbcc9b67283323b9432e23"}],"ComponentSizeInKB":23937,"CompsigList":["CP070871.compsig"],"FileList":["/CP070871_BUILD_8.data","/CP070871.vmexe64","/CP070871.vmfile","/CP070871_VMw.zip","/CP070871.xml","/payload.json","/CP070871_VMw.zip/index.xml","/CP070871_VMw.zip/vendor-index.xml","/CP070871_VMw.zip/metadata.zip","/CP070871_VMw.zip/vib20/CP070871/HPE_bootbank_CP070871_5.61.8-8.0.0.20613240.vib","/CP070871_VMw.zip/metadata.zip/vendor-index.xml","/CP070871_VMw.zip/metadata.zip/vmware.xml","/CP070871_VMw.zip/metadata.zip/vibs/CP070871--790202062578980553.xml","/CP070871_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070871_5.61.8-8.0.0.20613240.xml"],"Name":"CP070871.zip","SHA1Sum":"5cfdd0fe420cb5d367cec7836269095162439008","SHA256Sum":"9ecd22a5b03d8c5cc9c7f23d63ed1250a3aed12fd9dc7c4d9bb37931fb491993","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654"],"TypeOfChange":"1","Version":"5.61","VibList":[{"Name":"CP070871","Version":"5.61.8-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_477691debf2c4b71a008c01eed","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","A42","A43","A43","A42","HPE Apollo 2000 Gen10 Plus System","U61","U60","U46","U54","I45","U54","U54","U63","U63","A56","A55","A55","A56","U58","U59","U57","U65","U65","U62","U58","U58"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.fwpkg","SHA1Sum":"b4692fa59852868b966be1f76a565d1e75d9d137","SHA256Sum":"221449becbc98c0f50e46c46e01eaf80b091db8aab446310b581c410a58859bd","SHA512Sum":"0aaa97d5452c7c06477953aa687b2df938b3243c1603c41091c09ba8b7a9221a856f52d34ba13cfa66621a54baa4bb5170452c773def9089057ea478719cc9ff"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.xml","payload.json"],"Name":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.fwpkg","SHA1Sum":"b4692fa59852868b966be1f76a565d1e75d9d137","SHA256Sum":"221449becbc98c0f50e46c46e01eaf80b091db8aab446310b581c410a58859bd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f03491120a8a4309a21bea9e57","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","SHA512Sum":"e886f027b61bdbf23cda5f835e0bb8a179101152ec9dcf6c5c138e2e1a27cc7ac23a7e732fd7729b97690a46e4ea8dd1b2643a223497bfec59d2a180a711f88c"}],"ComponentSizeInKB":7328,"CompsigList":["firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063801.scexe"],"Name":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8526d39348f74098b531f4e304","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U50","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR216i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070859.zip","SHA1Sum":"e5b6b273e95c006682a526f7010eeca4b174a026","SHA256Sum":"92f05e066cdbca10c5bc2b6356c5a8c8fa7adb693da1c629b532131589447e9a","SHA512Sum":"8c13247ce36d1d2f707a1959a9d8f972d998b3d8cd5b03f8c85b3dc305f0d4d9c3a55120f8cc8f966a2347b30822ce3f84b7f588de590e4ebf6fb0e36d75f0b2"}],"ComponentSizeInKB":12765,"CompsigList":["CP070859.compsig"],"FileList":["/CP070859_BUILD_3.data","/CP070859.vmexe64","/CP070859.vmfile","/CP070859_VMw.zip","/CP070859.xml","/payload.json","/CP070859_VMw.zip/index.xml","/CP070859_VMw.zip/vendor-index.xml","/CP070859_VMw.zip/metadata.zip","/CP070859_VMw.zip/vib20/CP070859/HPE_bootbank_CP070859_52.26.3.5487.3-8.0.0.20613240.vib","/CP070859_VMw.zip/metadata.zip/vendor-index.xml","/CP070859_VMw.zip/metadata.zip/vmware.xml","/CP070859_VMw.zip/metadata.zip/vibs/CP070859--8866966811280889856.xml","/CP070859_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070859_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070859.zip","SHA1Sum":"e5b6b273e95c006682a526f7010eeca4b174a026","SHA256Sum":"92f05e066cdbca10c5bc2b6356c5a8c8fa7adb693da1c629b532131589447e9a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070859","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1cbb1c26de6f4bb7bb3b176396","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.fwpkg","SHA1Sum":"54cd7f3128875f7856d8443d44c50bc94ffb32a0","SHA256Sum":"3c1207be8dc30c201ec165e7508b8b9382dd960c3e447590051eb9fad52a0ff1","SHA512Sum":"f0edd17d1a5014341e2f4d6ec08d630ab5d308d574d9dcf797a0de1a2ca0e1bf5ff17c0ca483212ac29d2eb310090af100d8796a1ea156fb1968ee95eac5fb9c"}],"ComponentSizeInKB":10272,"CompsigList":[],"FileList":["HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.xml","payload.json"],"Name":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.fwpkg","SHA1Sum":"54cd7f3128875f7856d8443d44c50bc94ffb32a0","SHA256Sum":"3c1207be8dc30c201ec165e7508b8b9382dd960c3e447590051eb9fad52a0ff1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0ffd3d93f4e64e7d824fb7e99c","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-5.3.0-10.linux.x86_64.rpm","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","SHA512Sum":"2806683f99737f7293ac775fea15b30e54d281b7bf4fdfd4bb4ae5ca33bdd08e10919418a1e3d4ff66be1ca4bbc7ec8ca1d79d7bcc2a32c35de3f242231a70ab"}],"ComponentSizeInKB":7635,"CompsigList":["sut-5.3.0-10.linux.x86_64.compsig"],"FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/d01fe263104c65c66707eca3d31d173f66dc7e","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"Name":"sut-5.3.0-10.linux.x86_64.rpm","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"5.3.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_151e85c53b0b4ca0b072e7b487","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","15.0","8.0","9.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U69","U71","U69"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"cp069579.exe","SHA1Sum":"e7cb59b4f22da4c146aada4422c107f7a8b2b797","SHA256Sum":"aefb8493fd2f449db2758db28f2c13c76ffe8f7901a4c4ae13acbefbe4b6b137","SHA512Sum":"54d919f78904476ead7a45fd65c9e8e53293da9603b3db3d3e1dd0975b4825a6749c3e583576b527a5c64e456dd0eca4c64ac0ec4141d12a7b1fd192a44a7742"}],"ComponentSizeInKB":1733,"CompsigList":["cp069579.compsig"],"FileList":["cp069579.xml","cpqsetup.exe","HPE_NS204i_1.2.14.1018.bin","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp069579.exe","SHA1Sum":"e7cb59b4f22da4c146aada4422c107f7a8b2b797","SHA256Sum":"aefb8493fd2f449db2758db28f2c13c76ffe8f7901a4c4ae13acbefbe4b6b137","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Windows - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc87722faee84be4a9d5069381","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","U30","U32","A43","U41","U33","U46","U47","A46","U47","U50","I44","U46","U40","U39","A47","A48","A42","A43","A43","U43","A42","U44","U48","I45","U54","U54","U54","U63","U63","A55","A56","A56","A55","U59","U58","U58","U58","H10","H10","H10","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.rpm","SHA1Sum":"e46deec6f2d783539a47ce9259e9b0a93d0de335","SHA256Sum":"499fa2cf9da481fc5584320e0997620674ffacf2decb0a2332b31d33ccbe42b9","SHA512Sum":"3444eb4225711ec57885d59e65e833653fe0c0f3feb475f0ffe1784978d6dc6b90ed45a2e93016a5b41f895283d07bf082b7afce9f1dbf6c8c0ecea63a2d6810"}],"ComponentSizeInKB":8790,"CompsigList":["firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/CP068828.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068828.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068828.scexe"],"Name":"firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.rpm","SHA1Sum":"e46deec6f2d783539a47ce9259e9b0a93d0de335","SHA256Sum":"499fa2cf9da481fc5584320e0997620674ffacf2decb0a2332b31d33ccbe42b9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c4d82931ebd84881883ae3cc11","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U47","U60","U61","U65","U65","U57","U58","U58","I45","A56","U59","U63","U58","U54","U54","U54","U63","A55","A56","A55","U62"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.fwpkg","SHA1Sum":"93879152515d558b14687a6a16f59a5c0893ec0d","SHA256Sum":"8b4a3f8959ffea3feb8881faf445daf349f93179dcd65fa78c98ad5abd1566b5","SHA512Sum":"ab368c2f33e10993a1f20d54566e17d1d1362866c735026351d1102327804b9fd95040a52af64c747a56e4371c223e23d418b19bdc851d4ac8f87a2233c7fa97"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.xml","payload.json"],"Name":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.fwpkg","SHA1Sum":"93879152515d558b14687a6a16f59a5c0893ec0d","SHA256Sum":"8b4a3f8959ffea3feb8881faf445daf349f93179dcd65fa78c98ad5abd1566b5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c59babb0feb45a28cbb8082d3","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860006"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.fwpkg","SHA1Sum":"ba012c49e28671973d14f4281e4a13fde04ec409","SHA256Sum":"378c3a939e17060e5d877ff5e9a90999d08ea1fc45be853efac52c44500b7958","SHA512Sum":"81e27ca1e9dc24cc355fd6d5976574911a7874e7dc0bc9d8e1128e2824a009de6f7fb2cd6cee3a646aa08b2dce7e0e5003e33358e0d600a50d21e97c648cd522"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.xml","payload.json"],"Name":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.fwpkg","SHA1Sum":"ba012c49e28671973d14f4281e4a13fde04ec409","SHA256Sum":"378c3a939e17060e5d877ff5e9a90999d08ea1fc45be853efac52c44500b7958","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6b034d64eeaf4e40847dab79d8","SupportedDevices":["a6b1a447-382a-5a4f-8086-15928086000e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Files":[{"Checksum":[{"Filename":"CP070641.zip","SHA1Sum":"3ded184429e012f94f458d933584fdb6ef3829e4","SHA256Sum":"11de7d29ec51bc29bf23e09df39a89cec479e6a6ebea2645346e95fd884b095c","SHA512Sum":"73f7b07a4e88d8a3a35ab1183bb33fdc4137150d9cc04a3fd712e04799b36de6641b0e6fbea4a1cb67201f41c98309acc9d53e20ad9dddf6eb285d0ba5766647"}],"ComponentSizeInKB":19004,"CompsigList":["CP070641.compsig"],"FileList":["/CP070641_BUILD_9.data","/CP070641.vmexe64","/CP070641.vmfile","/CP070641_VMw.zip","/CP070641.xml","/payload.json","/CP070641_VMw.zip/index.xml","/CP070641_VMw.zip/vendor-index.xml","/CP070641_VMw.zip/metadata.zip","/CP070641_VMw.zip/vib20/CP070641/HPE_bootbank_CP070641_226.1.107.0.9-8.0.0.20613240.vib","/CP070641_VMw.zip/metadata.zip/vendor-index.xml","/CP070641_VMw.zip/metadata.zip/vmware.xml","/CP070641_VMw.zip/metadata.zip/vibs/CP070641--2039479615732845808.xml","/CP070641_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070641_226.1.107.0.9-8.0.0.20613240.xml"],"Name":"CP070641.zip","SHA1Sum":"3ded184429e012f94f458d933584fdb6ef3829e4","SHA256Sum":"11de7d29ec51bc29bf23e09df39a89cec479e6a6ebea2645346e95fd884b095c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0","VibList":[{"Name":"CP070641","Version":"226.1.107.0.9-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ffa6d2091834a238547a7df8d","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180114e41599"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U64","U65","U65","U65","U46","U58","U59","A56","A56","A55","A55","U63","U62","U63","H10","H10","U58","U58","U60","U61","U54","H10","U56","U54","U54","A42","HPE Apollo 2000 Gen10 Plus System","U50","U47","U48","U47","A46","U47","U50","A43","A43","A43","U46","A42","U46","A42","U70","U71","U69","U70"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"firmware-9041739931-1.2.14.1018-4.1.x86_64.rpm","SHA1Sum":"bf17326d34d078afc7a9909f754188fa715e4a7b","SHA256Sum":"87613aec9bada5568a3ece569e924f75ffd71a585f3e1223ba328f2b1b86ef62","SHA512Sum":"21d4561efb795794991586efeaeb6bb495f03ac0668721ca19383b703809ac7e094fc0826b87eb2b273a4f7b867e195ab83d27a1bd8ada82ed8a46e5835722ef"}],"ComponentSizeInKB":1449,"CompsigList":["firmware-9041739931-1.2.14.1018-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/CP068829.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068829.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068829.scexe"],"Name":"firmware-9041739931-1.2.14.1018-4.1.x86_64.rpm","SHA1Sum":"bf17326d34d078afc7a9909f754188fa715e4a7b","SHA256Sum":"87613aec9bada5568a3ece569e924f75ffd71a585f3e1223ba328f2b1b86ef62","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Linux(x64) - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_802cc53b3799481086fb450dc3","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I44","U46","A42","U34","U34","A42","U46","U30","U32","A43","A43","A43","U43","U41","U33","U44","A47","A48","U47","A46","U47","U48","U40","U50","U39","A42","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"CP070870.zip","SHA1Sum":"650f5a095f9854b6955dde4d09ff0cc40febc92b","SHA256Sum":"9fb6f0f9cbcd2ba606a9df3972ef4fedb7792fe44942112b5b69b57ffbeac4b0","SHA512Sum":"33f02bfc6f67f1fd355a77e026a4a6cb13ce2c52f2b5ce7a179824b93ececd33c7378e9aec3b331b458876a9d1f3afb3cdfe8e55d50f948ccc6d512b32749db7"}],"ComponentSizeInKB":2464,"CompsigList":["CP070870.compsig"],"FileList":["/CP070870_BUILD_4.data","/CP070870.vmexe","/CP070870.vmexe64","/CP070870.vmfile","/CP070870_VMw.zip","/CP070870.xml","/payload.json","/CP070870_VMw.zip/index.xml","/CP070870_VMw.zip/vendor-index.xml","/CP070870_VMw.zip/metadata.zip","/CP070870_VMw.zip/vib20/CP070870/HPE_bootbank_CP070870_1.2.14.1018.4-8.0.0.20613240.vib","/CP070870_VMw.zip/metadata.zip/vendor-index.xml","/CP070870_VMw.zip/metadata.zip/vmware.xml","/CP070870_VMw.zip/metadata.zip/vibs/CP070870-6632410356789207801.xml","/CP070870_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070870_1.2.14.1018.4-8.0.0.20613240.xml"],"Name":"CP070870.zip","SHA1Sum":"650f5a095f9854b6955dde4d09ff0cc40febc92b","SHA256Sum":"9fb6f0f9cbcd2ba606a9df3972ef4fedb7792fe44942112b5b69b57ffbeac4b0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018","VibList":[{"Name":"CP070870","Version":"1.2.14.1018.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online Firmware Flash for ESXi - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2965a33e83ba4d60875eeeb4cd","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","U30","U32","A43","U41","U33","U47","A46","U47","U50","I44","U46","U46","U39","U40","A47","A48","A42","A43","A43","U43","A42","U44","U48","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10","U46","H11","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"CP070643.zip","SHA1Sum":"e001a275c52c3c8f9a5e5087fb58f24b1d57936f","SHA256Sum":"cadda3d28c4dc4764b28760b4e447bb7c56e88f74e9b1df30dc7e774d1797ec5","SHA512Sum":"eecc42648156a0c388bbbe78b6e3d744da291b87caff967f9e6eb505533bc579f98497d6620be5ad323b21e02159015cfa90e1881806fcccda5fd167740de73d"}],"ComponentSizeInKB":27572,"CompsigList":["CP070643.compsig"],"FileList":["/CP070643_BUILD_9.data","/CP070643.vmexe64","/CP070643.vmfile","/CP070643_VMw.zip","/CP070643.xml","/payload.json","/CP070643_VMw.zip/index.xml","/CP070643_VMw.zip/vendor-index.xml","/CP070643_VMw.zip/metadata.zip","/CP070643_VMw.zip/vib20/CP070643/HPE_bootbank_CP070643_8.55.12.9-8.0.0.20613240.vib","/CP070643_VMw.zip/metadata.zip/vendor-index.xml","/CP070643_VMw.zip/metadata.zip/vmware.xml","/CP070643_VMw.zip/metadata.zip/vibs/CP070643--2511290925962530306.xml","/CP070643_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070643_8.55.12.9-8.0.0.20613240.xml"],"Name":"CP070643.zip","SHA1Sum":"e001a275c52c3c8f9a5e5087fb58f24b1d57936f","SHA256Sum":"cadda3d28c4dc4764b28760b4e447bb7c56e88f74e9b1df30dc7e774d1797ec5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP070643","Version":"8.55.12.9-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_beac71715d1b4ab284ce0cf4b4","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"cp070139.exe","SHA1Sum":"eb1bc70dac2542fad3208d595b311f7d59d60505","SHA256Sum":"e2a1cdebe8aeeae1439eb454f74d8123e23de5581bc617ed0f51045aa289894e","SHA512Sum":"ec1b063d3b9a798d094778a7b977e2c7b6911333bf4666ed1b00819f32c5c3b48fc1c34ed83991b0441e0e58d946219ec71e5481e7036811c03ac84ba374a0b9"}],"ComponentSizeInKB":17462,"CompsigList":["cp070139.compsig"],"FileList":["cp070139.xml","cpqsetup.exe","ilo5_148.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"Name":"cp070139.exe","SHA1Sum":"eb1bc70dac2542fad3208d595b311f7d59d60505","SHA256Sum":"e2a1cdebe8aeeae1439eb454f74d8123e23de5581bc617ed0f51045aa289894e","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47c837c7bc774252a1748f8034","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.1","6.3","6.2","6.2","6.3","10.0","10.0.17600.18999","6.0","6.0","5.1","5.2","10.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","U46","U46","U47","A46","U47","U47","U50","I44","A42","U51","A45"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"cp067918.exe","SHA1Sum":"ebbbdc2856035c4c18e359bc04a94ec55c42a209","SHA256Sum":"cb79175d4be1ede24cc6d2d728c6ebba68e6dfd4bb45c2a64095c4ae77ed56f7","SHA512Sum":"163c5c709a116c2b6c928a02c51b15587cb450bdf9031df5461034b5c5c3c803efb5a6678d5c678f7db80c04bd796bb575faf0381c910e1b6c5979b14be9facd"}],"ComponentSizeInKB":7081,"CompsigList":["cp067918.compsig"],"FileList":["cp067918.xml","cpqsetup.exe","HPE_luxor_5.61.bin.fw","payload.json","setup.dll"],"Name":"cp067918.exe","SHA1Sum":"ebbbdc2856035c4c18e359bc04a94ec55c42a209","SHA256Sum":"cb79175d4be1ede24cc6d2d728c6ebba68e6dfd4bb45c2a64095c4ae77ed56f7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c1becc9ec194435c8ad7529bca","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","A42","A43","A43","A42","HPE Apollo 2000 Gen10 Plus System","U60","U61","U65","U65","U57","U58","U58","I45","A56","U58","U54","U54","U54","U63","U63","U59","U62"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.fwpkg","SHA1Sum":"77bcc81598acc820859e00b84ec36faf529522a3","SHA256Sum":"b2beae73117355f6488f71a02518a5c2bb333ebaf7122a0dd41ecfbf814d2b58","SHA512Sum":"c838ab2aa3f4dabb6daccb3ade34bb47de32f63e3633e245d9b7e0e04bf4188f6e3ab81da96cd34475a0a6b7bf8a33290ab02e09d06c046c6bb057f315368f34"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.xml","payload.json"],"Name":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.fwpkg","SHA1Sum":"77bcc81598acc820859e00b84ec36faf529522a3","SHA256Sum":"b2beae73117355f6488f71a02518a5c2bb333ebaf7122a0dd41ecfbf814d2b58","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fe74ccfcd503410b98d0aedd67","SupportedDevices":["a6b1a447-382a-5a4f-8086-159380860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"ilo5_148.fwpkg","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","SHA512Sum":"663e9acb6419408de6c6eb8f4c5ecf22631b264440d9a38b9d13e692e45c31bfec792ed78d3bc2a44587bf257ee1b126ff1f7a701a35da592e595200bfe04ff3"}],"ComponentSizeInKB":32802,"CompsigList":[],"FileList":["ilo5_148.bin","ilo5_148.xml","payload.json","readme.txt"],"Name":"ilo5_148.fwpkg","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"0","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f0bb94c6dff64cb39c8fb14c2d","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","A42","U46","U46","A43","U51","U47","A46","A45","U47","U47","U50","I44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR216i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070860.zip","SHA1Sum":"90270c4ba411aa61668b24e36eacde7a2a2f9327","SHA256Sum":"45f77bb97891e1e7318824ba8295dc9fe173e4a35346821a7e1554a70c595562","SHA512Sum":"0d5c9ab4b9807df9105e8423eadf7ca7142843da1494ec7cb80119ec85d626ead50b706725ee7afc545ecd652272d74f281455286b0181a29efbe1b05f92844c"}],"ComponentSizeInKB":12765,"CompsigList":["CP070860.compsig"],"FileList":["/CP070860_BUILD_3.data","/CP070860.vmexe64","/CP070860.vmfile","/CP070860_VMw.zip","/CP070860.xml","/payload.json","/CP070860_VMw.zip/index.xml","/CP070860_VMw.zip/vendor-index.xml","/CP070860_VMw.zip/metadata.zip","/CP070860_VMw.zip/vib20/CP070860/HPE_bootbank_CP070860_52.26.3.5487.3-8.0.0.20613240.vib","/CP070860_VMw.zip/metadata.zip/vendor-index.xml","/CP070860_VMw.zip/metadata.zip/vmware.xml","/CP070860_VMw.zip/metadata.zip/vibs/CP070860-775760543429782998.xml","/CP070860_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070860_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070860.zip","SHA1Sum":"90270c4ba411aa61668b24e36eacde7a2a2f9327","SHA256Sum":"45f77bb97891e1e7318824ba8295dc9fe173e4a35346821a7e1554a70c595562","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070860","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ff259d4bb8914bcdaa802549ad","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","SHA512Sum":"343b267badd7f3e5291be35e4ece717751a2c900ef7bb50e04aaf25ada949a69ba9c4f23fa336a7151ae3ae4e0c0da4106ffea38d7309cdf3b0036dc50c312a6"}],"ComponentSizeInKB":2124,"CompsigList":["firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw/ql_hp_ah_mbi_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061237.scexe"],"Name":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f7626fc8ae84aa7aa653c82a1","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM957504 100G 1P QSFP56 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E45100","Version":"226.1.107.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-bcm-nxe_226.1.107.0-1.1_amd64.deb","SHA1Sum":"38daa0d42ae3596351d284794b8152ac965dc06d","SHA256Sum":"007a09041172265d728185bfcda150fdce63ec3dda2d36b84f4a8073ccdacf7d","SHA512Sum":"adc156e969e520badc8e6a398d672574ad27cfee9c3799b306b6713c029cfd93635ca617c0d3f2c9a881bdd632218fd91b7caf5c1db70b5fb4f30d2d7fc557f0"}],"ComponentSizeInKB":2230,"CompsigList":["firmware-nic-is-bcm-nxe_226.1.107.0-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/CP068817.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/CP068817.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957412A4121HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957412N4120HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957414A4142HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957414N4140HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957416A4162HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957416N4160HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957504A504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/nic_fw/BCM957504N504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068817.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068817.scexe"],"Name":"firmware-nic-is-bcm-nxe_226.1.107.0-1.1_amd64.deb","SHA1Sum":"38daa0d42ae3596351d284794b8152ac965dc06d","SHA256Sum":"007a09041172265d728185bfcda150fdce63ec3dda2d36b84f4a8073ccdacf7d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599","a6b1a447-382a-5a4f-14E4-175114E45100"],"TypeOfChange":"1","Version":"226.1.107.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5d7180125efc4487bd07cf626a","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-175114e45100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U30","U32","U43","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U46","U65","U65","U65","U70","U71","U69","U71","U69","U58","U70"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.fwpkg","SHA1Sum":"035edc90e72969b4a023d4620531de0006bad125","SHA256Sum":"25858cd4cb92a97b30435fa1f770ffe9c418a132f16bc1c09be8bc8077e23c40","SHA512Sum":"9a18bde884015785a54eaf976ae264c7c63a70b8dae520e23661c1bf4eb7d7037d867a00110374a2daf8a370eeb40f3f1c1d3ebe87e67df587361e4f89fefaf2"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.xml","payload.json"],"Name":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.fwpkg","SHA1Sum":"035edc90e72969b4a023d4620531de0006bad125","SHA256Sum":"25858cd4cb92a97b30435fa1f770ffe9c418a132f16bc1c09be8bc8077e23c40","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9bf17c21318f468fad349e91c4","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.deb","SHA1Sum":"a337929c31c9a16771833fba8c4a03d6b0ee7d8d","SHA256Sum":"ab98326d2081e30c5fe3f59a458394f7fd629569784041fd72b5214ed4d1adf8","SHA512Sum":"bb3e82e983cd6e473101f573272deb38f52aef6024ff712a9b2ed0778bb8b22488aaf20d1aa7b750027d758461c2fb9b77805eec246a92c0ec09fbc9df837737"}],"ComponentSizeInKB":1311,"CompsigList":["firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068813.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068813.scexe"],"Name":"firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.deb","SHA1Sum":"a337929c31c9a16771833fba8c4a03d6b0ee7d8d","SHA256Sum":"ab98326d2081e30c5fe3f59a458394f7fd629569784041fd72b5214ed4d1adf8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb1b62b98ea044789fa1f3c146","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U50","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"cp069751.exe","SHA1Sum":"de44dd46826c0149e22f30684eb9dd42a32f0b64","SHA256Sum":"ba9f333a627b6efb0ad6dc0128dfbf4380f38040314ff1e3e68f2ee3b032e447","SHA512Sum":"36d7e1c6ef09eb8f95664e3deddcb3fd616844d1801ae4a2135136be91c841cd449cd622cb824a0303ff8538b36b3d271c99947b25c4be8175cf2e75f0488c45"}],"ComponentSizeInKB":9678,"CompsigList":["cp069751.compsig"],"FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp069751.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069751.exe","SHA1Sum":"de44dd46826c0149e22f30684eb9dd42a32f0b64","SHA256Sum":"ba9f333a627b6efb0ad6dc0128dfbf4380f38040314ff1e3e68f2ee3b032e447","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EE15900212"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21283c052dce4f2493e243981f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ee15900212"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","U26","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.fwpkg","SHA1Sum":"8340791f033723a38702b6ab59c68f3522181df9","SHA256Sum":"76a117c2c99fdda0d22fc2d2fddda6058579039eab6c4a2a7e78ecbcdd1b028b","SHA512Sum":"3420fab3d0c4d08de96f53d4dfdd4e83d9b34ead37f738fc3ff52ac03f1df0339e5f8326912c45f72fa332e3f79a2f6985b1b6b82f6fa7a7929460632ddb26ec"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.fwpkg","SHA1Sum":"8340791f033723a38702b6ab59c68f3522181df9","SHA256Sum":"76a117c2c99fdda0d22fc2d2fddda6058579039eab6c4a2a7e78ecbcdd1b028b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_51458cdc933e445a85a609c281","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Files":[{"Checksum":[{"Filename":"cp069752.exe","SHA1Sum":"b6edb534cf50283c454153e55f25e513e19a2268","SHA256Sum":"63d8a1cfaaf90b26ce68f2d25613b1c707311367885c85fc44f4e4d6400129c9","SHA512Sum":"1dd2c849641608e7bfa2d2327629bdc497b9b973c8a39cc67b515deb8afe3eabc6ca49b305f1bcbe1abd9251004cf6a2aa9076b713c85de76f71679f4665c762"}],"ComponentSizeInKB":11545,"CompsigList":["cp069752.compsig"],"FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp069752.xml","cpqsetup.exe","FW/","FW/BCM957412A4121HC.pkg","FW/BCM957412N4120HC.pkg","FW/BCM957414A4142HC.pkg","FW/BCM957414N4140HC.pkg","FW/BCM957416A4162HC.pkg","FW/BCM957416N4160HC.pkg","FW/BCM957504A504H.pkg","FW/BCM957504N504H.pkg","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069752.exe","SHA1Sum":"b6edb534cf50283c454153e55f25e513e19a2268","SHA256Sum":"63d8a1cfaaf90b26ce68f2d25613b1c707311367885c85fc44f4e4d6400129c9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6a3469b568764167a98158c4c0","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180114e41599"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U60","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","U70","U71","U69","U70"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"CP070642.zip","SHA1Sum":"55b7207da30751741fb70fcabb2cff38e0b0b446","SHA256Sum":"71b1fe1e1083564a3be027f309b7253da376684ef86257bccf8015c2fa17b4e0","SHA512Sum":"4870eb749b741c8e3e305e1339d8ead4db30d68ed3214cde101dfe68f2904ed23c348694508f42d8533dd2c54fccfb10118fd4a5a00a829e76c343dfc56356a8"}],"ComponentSizeInKB":30683,"CompsigList":["CP070642.compsig"],"FileList":["/CP070642_BUILD_7.data","/CP070642.vmexe64","/CP070642.vmfile","/CP070642_VMw.zip","/CP070642.xml","/payload.json","/CP070642_VMw.zip/index.xml","/CP070642_VMw.zip/vendor-index.xml","/CP070642_VMw.zip/metadata.zip","/CP070642_VMw.zip/vib20/CP070642/HPE_bootbank_CP070642_8.55.12.7-8.0.0.20613240.vib","/CP070642_VMw.zip/metadata.zip/vendor-index.xml","/CP070642_VMw.zip/metadata.zip/vmware.xml","/CP070642_VMw.zip/metadata.zip/vibs/CP070642-6122126821504098736.xml","/CP070642_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070642_8.55.12.7-8.0.0.20613240.xml"],"Name":"CP070642.zip","SHA1Sum":"55b7207da30751741fb70fcabb2cff38e0b0b446","SHA256Sum":"71b1fe1e1083564a3be027f309b7253da376684ef86257bccf8015c2fa17b4e0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP070642","Version":"8.55.12.7-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd12209b390a4e6d8a9345d202","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","9.0","8.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","SHA512Sum":"e709b769e482c2d817458719553be5a68e983731de45357d61958226c9cc7d4fbf2866656d2818a36d65d334a522a900b872509ffaaa9285b133dd6fd42e5c0a"}],"ComponentSizeInKB":2168,"CompsigList":["firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw/ql_ah_mbi_open_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061236.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061236.scexe"],"Name":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df0d2e84414545c18a181d95d2","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR416i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070861.zip","SHA1Sum":"109edd1792a3a876e0e70cdd8f2be89daad2f91d","SHA256Sum":"da063f438994c18533d2466a36ded1f10ad6bf260668c12a16ea02df7dacd8f3","SHA512Sum":"87dbda50fd5fb600bfe86e5430129bc748e3463ad97d1b3aea5856fe377576ee7e70f0eade47a52df7ad7753e7da3425aa1c0df0f563f1f4553c4203e3e957eb"}],"ComponentSizeInKB":12765,"CompsigList":["CP070861.compsig"],"FileList":["/CP070861_BUILD_3.data","/CP070861.vmexe64","/CP070861.vmfile","/CP070861_VMw.zip","/CP070861.xml","/payload.json","/CP070861_VMw.zip/index.xml","/CP070861_VMw.zip/vendor-index.xml","/CP070861_VMw.zip/metadata.zip","/CP070861_VMw.zip/vib20/CP070861/HPE_bootbank_CP070861_52.26.3.5487.3-8.0.0.20613240.vib","/CP070861_VMw.zip/metadata.zip/vendor-index.xml","/CP070861_VMw.zip/metadata.zip/vmware.xml","/CP070861_VMw.zip/metadata.zip/vibs/CP070861--5824522441084647177.xml","/CP070861_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070861_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070861.zip","SHA1Sum":"109edd1792a3a876e0e70cdd8f2be89daad2f91d","SHA256Sum":"da063f438994c18533d2466a36ded1f10ad6bf260668c12a16ea02df7dacd8f3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070861","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2bfd49954b34412891e51a2b26","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"cp069753.exe","SHA1Sum":"f4de67e356ae382d872f093571a758232e720cbf","SHA256Sum":"f1821ebb7e0d4ff2d557fdbd5fd739752d49109a61b05d939969014370d23154","SHA512Sum":"306b7ad25777fbc2637daed18163be276d233eeee083d1ae041db2819e53f5a32eb77e87bd789019a1f37a4eb4a2f758a965fa4d94e7a8d0f9bdf583d3b679f4"}],"ComponentSizeInKB":3039,"CompsigList":["cp069753.compsig"],"FileList":["cp069753.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069753.exe","SHA1Sum":"f4de67e356ae382d872f093571a758232e720cbf","SHA256Sum":"f1821ebb7e0d4ff2d557fdbd5fd739752d49109a61b05d939969014370d23154","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc98c2801e0d41d9863df18abc","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR416i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070862.zip","SHA1Sum":"e10965c4edb70843908488fd733cdd24fd11a332","SHA256Sum":"8a10bac4680cb27eb1a6dc9888fd5dd1d7df2ede7bc496622e1b92d39ebf097e","SHA512Sum":"de22e2eeb59e7aac83fcd5351fc2f1b30dcb0f240a487d6a24e5091f242268c2c0e9cea54bde90d172cdef1a04533ce8f1aa262800982f869b8eae57f8f7976d"}],"ComponentSizeInKB":12765,"CompsigList":["CP070862.compsig"],"FileList":["/CP070862_BUILD_6.data","/CP070862.vmexe64","/CP070862.vmfile","/CP070862_VMw.zip","/CP070862.xml","/payload.json","/CP070862_VMw.zip/index.xml","/CP070862_VMw.zip/vendor-index.xml","/CP070862_VMw.zip/metadata.zip","/CP070862_VMw.zip/vib20/CP070862/HPE_bootbank_CP070862_52.26.3.5487.6-8.0.0.20613240.vib","/CP070862_VMw.zip/metadata.zip/vendor-index.xml","/CP070862_VMw.zip/metadata.zip/vmware.xml","/CP070862_VMw.zip/metadata.zip/vibs/CP070862-1494320092552196309.xml","/CP070862_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070862_52.26.3.5487.6-8.0.0.20613240.xml"],"Name":"CP070862.zip","SHA1Sum":"e10965c4edb70843908488fd733cdd24fd11a332","SHA256Sum":"8a10bac4680cb27eb1a6dc9888fd5dd1d7df2ede7bc496622e1b92d39ebf097e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070862","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4706752d8ba24ef0852ae16695","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"cp069754.exe","SHA1Sum":"3c19f6f6a393d21c224c378f7da3d8e2665f1fec","SHA256Sum":"e86be90d623a7b913d77af5ac79ae6d5be70c848086592cb06e31c8d9b00d20f","SHA512Sum":"92794a063702ef82b179d15487e5c1364bfe18437ca9d811b6d6aae0f9578622aad2a208324c66c0574951d7f79d5c700d91ba3062fd24e2a45927e0328e6c9d"}],"ComponentSizeInKB":3083,"CompsigList":["cp069754.compsig"],"FileList":["cp069754.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_ah_mbi_open_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069754.exe","SHA1Sum":"3c19f6f6a393d21c224c378f7da3d8e2665f1fec","SHA256Sum":"e86be90d623a7b913d77af5ac79ae6d5be70c848086592cb06e31c8d9b00d20f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5d468adc62504bb6a685fd6edf","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]}],"SupplementBundleLocation":[],"VMwareAddonInfo":[{"ComponentLocation":"","FileName":"HPE-803.0.0.10.25.0.11-Jul2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-07-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"d74a376a3bf558e518fa4bda271fb49d676b0f9a","SHA256Sum":"da1513e7940b9f87ee1861bdb7c3834d438b14be3c682b73056b5ba0e7dc22ba","SizeInKB":40619,"SupportedBaseImageVersions":["8.0.3"],"VersionSpec":{"UIString":"803.0.0.10.25.0-11","Version":"803.0.0.10.25.0-11"}},{"ComponentLocation":"","FileName":"HPE-900.0.0.10.9.0.12-Jul2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-07-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"7e1c4473ba2b823956ff6f8dc764e075fce09ba9","SHA256Sum":"7153029930debe304227afe0f9d0adcec9a6b35e6288ef50f153c0351f7ddd9c","SizeInKB":38761,"SupportedBaseImageVersions":["9.0"],"VersionSpec":{"UIString":"900.0.0.10.9.0-12","Version":"900.0.0.10.9.0-12"}},{"ComponentLocation":"","FileName":"HPE-910.0.0.10.3.0.12-Jul2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-07-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"617548a6eb0d4d004268e60537d8de127194e084","SHA256Sum":"33c9fb491b0f472f71fabf54afa5312aa8777e007457c49d543560baa79bc4e2","SizeInKB":38491,"SupportedBaseImageVersions":["9.1"],"VersionSpec":{"UIString":"910.0.0.10.3.0-12","Version":"910.0.0.10.3.0-12"}}]}],"SchemaVersion":"2.0"}