<?xml version="1.0" encoding="UTF-8"?>
<manifest schema_version="2.0.0.0">
  <meta lang="ja">
    <product id="2e4ac8b988164dc087668639a95037d3">
      <product_version>
        <id product="2e4ac8b988164dc087668639a95037d3" version="9c49ee19d58543b99d302ba61aa1dcf3" lucid_version="tg3.rhel10@3.140b-1__pubsw-linux_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="3.140b-1" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、Red Hat Enterprise Linux 10下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 10.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>インストールのノートについてREADMEをダウンロードします。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download README for installation notes.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1665</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22E8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">1786</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">169D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">3383</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159C</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-tg3" guid="20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-tg3" guid="20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-tg3-3.140b-1.rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="162KB" bytes="166607" date_modified="2026-09-03T03:18:07" md5sum="7b23bc59cc9cd391f33fb395e04b91cf" sha1sum="449d546cab5adb598c5d9391fca3bbe4c056d2b7" sha256sum="eafe7d1a28bfcff40302c4e5a75294db5bb70823194a7f388dbd2325cf1d927a" sha512sum="1fd7764d9d70efe6e0097c6ee01d63b33b19ecf09a70b524845ea9c95ae0ad476a87b05aee1f2e7f1a0e1fb038f00dcc5a5626e2e8582e58c2d6de273d5cccb2" version="3.140b" release="1.rhel10u1">
            <name>kmod-tg3-3.140b-1.rhel10u1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-tg3-3.140b-1.rhel10u1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/tg3.conf</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3/tg3.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/65</file>
              <file>./usr/lib/.build-id/65/ae9dc44655a730ea8c824e69b7c7bb32c1df60</file>
              <file>./usr/share/smartupdate/kmod-tg3/component.xml</file>
            </file_list>
          </file>
          <file size="162KB" bytes="166657" date_modified="2026-09-03T03:22:21" md5sum="37009ce8e8246221deddaf3acc1fd3af" sha1sum="1e609b422e8579fb4c87be9b25ad98e0792c3477" sha256sum="f10e8c2b3af5151d550c7dea67d2ae2e84b611b0eee93b9f1f6cbb65346362f3" sha512sum="2bd4e67bac099533c839ed263926da5bd083ab3425aeafd4743a63e43fadacec9287a18ae97b6dafd544d17a676089e326c3b807902257545d75ff4b67855381" version="3.140b" release="1.rhel10u2">
            <name>kmod-tg3-3.140b-1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-tg3-3.140b-1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/tg3.conf</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/tg3</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/tg3/tg3.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/07</file>
              <file>./usr/lib/.build-id/07/1366838bbe2ec41d25297a1aa18ff1ee523338</file>
              <file>./usr/share/smartupdate/kmod-tg3/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="28d64870513f44508fc5c9982e6527cc">
      <product_version>
        <id product="28d64870513f44508fc5c9982e6527cc" version="b95ceca075be4754bffd9b2c9be5cc95" lucid_version="venice.win2025.x64@7.9.29.304__sc-windows_en,ja"/>
        <different>new</different>
        <build number="4"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Identifier for AMD EPYC Processors (Sixth Generation) for Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">Identifier for AMD EPYC Processors (Sixth Generation) for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Identifier for AMD EPYC Venice Processors</alt_name_xlate>
          <alt_name_xlate lang="en">Identifier for AMD EPYC Venice Processors</alt_name_xlate>
        </alt_name>
        <version value="7.9.29.304" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300094">
          <category_xlate lang="ja">ドライバ - チップセット</category_xlate>
          <category_xlate lang="en">Driver - Chipset</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This component installs INFs to identify devices in the processor.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This component installs INFs to identify devices in the processor.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>

<p>From that drive and directory, execute the downloaded file.</p>

<p>Click the &quot;Install&quot; button to proceed with the installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>

<p>From that drive and directory, execute the downloaded file.</p>

<p>Click the &quot;Install&quot; button to proceed with the installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices/>
          <supported_platforms>
            <supported_platform rom="A72"/>
          </supported_platforms>
          <required_diskspace size_kb="1000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="installer.dll" guid="20a6e8e4-bf33-4c71-a6bf-d9ec6a179209">
              <sw_key_expectedpath>%ProgramFiles%\Hewlett Packard Enterprise\chipset</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071646.exe</filename>
        <component_config/>
        <files>
          <file size="686KB" bytes="703288" date_modified="2026-09-14T03:24:14" md5sum="aa6d3aae23272805e28b5bd57c362cda" sha1sum="72ae12fb52acb5818ae2af4afb71ea903909c60e" sha256sum="a524d58ea218bbb9bacd350930380bcb1f90d46cb01d34a956c9940870eda8b8" sha512sum="bd5831c91cbc313d3a1245737dacee24c970224ca5a2facf77713c62ae4c0c655c65bee4eb2363825d9046199fa04a0903b5a833d56a541b02a1afe37809d996">
            <name>cp071646.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071646.exe</url>
            <file_list>
              <file>cp071646.xml</file>
              <file>cpqsetup.exe</file>
              <file>installer.dll</file>
              <file>pnp/</file>
              <file>pnp/amddrtm.cat</file>
              <file>pnp/amddrtm.dll</file>
              <file>pnp/amddrtm.inf</file>
              <file>pnp/amdhsmpdriver.cat</file>
              <file>pnp/AmdHSMPDriver.inf</file>
              <file>pnp/AMDInterface.cat</file>
              <file>pnp/AMDInterface.inf</file>
              <file>pnp/amdpsp.cat</file>
              <file>pnp/amdpsp.inf</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="c013d920d5db4350b0283f4634a4df97">
      <product_version>
        <id product="c013d920d5db4350b0283f4634a4df97" version="cecbbb957c2d4c39821cbc21aa3535c8" lucid_version="nicfwpkg_bcme_57608_2p100ocp@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57608 100GbE 2p OCP3 Adapter</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57608 100GbE 2p OCP3 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57608 100GbE 2p OCP3 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57608 100GbE 2p OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57608 100GbE 2p OCP3 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57608 100GbE 2p OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 OCP3 Adapter for HPE</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 OCP3 Adapter for HPE</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57608_2P100OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957608-N2100HQI00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="3MB" bytes="3683989" date_modified="2026-08-18T05:46:21" md5sum="4be4a4425015b08efda6288315696428" sha1sum="6b1236c2fb370655a88116d8213445b90a88a698" sha256sum="e8645bdf8a837a129e7b83687d75bef624ef6704fc9f367e370d905623a4072d" sha512sum="024dcabfac9241ea305661c992afe105bf51b0790939080ffa6ecf4492a747146f2f908dd437c7c0d706211667fcba3ff43586cf45ea318d0731b4de8ce777cb">
            <name>BCM238.1.169.0_BCM957608-N2100HQI00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957608-N2100HQI00.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957608-N2100HQI00.HPb</file>
              <file>BCM238.1.169.0_BCM957608-N2100HQI00.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57608 100GbE QSFP112 OCP3 Adptr</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957608-N2100HQI00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-176014e4e324</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="463a2c9efd1a42e6b03a6e78f84f217e">
      <product_version>
        <id product="463a2c9efd1a42e6b03a6e78f84f217e" version="36ad3244adbd4703ba78505e65953b47" lucid_version="nicfwpkg_bcme_57414_2p25ocp_dr@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="26"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57414 SFP28 OCP3 Dual Rate Adapter</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57414 SFP28 OCP3 Dual Rate Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57414 SFP28 OCP3 Dual Rate Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57414 SFP28 OCP3 Dual Rate Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 SFP28 OCP3 Dual Rate Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 SFP28 OCP3 Dual Rate Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 OCP3 Dual Rate Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 OCP3 Dual Rate Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57414OCP_DUALRATE_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957414N4140HDR.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1398894" date_modified="2026-08-18T06:40:16" md5sum="fbef985bf43e26654dbacbb69236e440" sha1sum="5e779529697d8e39f6eaa4952e5da73c2c556838" sha256sum="c7ead000b2a0373dd46eff91792b68842fda78b04362d1f2176b2c44eaedd920" sha512sum="8065f2bc1b8b10c82d6736aeebbfd41237ba1396c75c8195eb8d94dbf3ecc4cb3e911e4e27ba37012fe60d1c111b3c2d44bdf8d2fd876b0e6ec36e00626ab601">
            <name>BCM238.1.169.0_BCM957414N4140HDR.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957414N4140HDR.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957414N4140HDR.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d714e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ec14e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ed14e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16dc14e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c114e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c514e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 OCP3 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16bd14e4e322</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="2432f89456d4439e8b4887185dba490d">
      <product_version>
        <id product="2432f89456d4439e8b4887185dba490d" version="ade6326a99a944eb90a31c8fd7902f21" lucid_version="intel_lkv_vf.w2k25@2.3.7.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="4"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Intel vxsドライバーfor Windows Server 2025</name_xlate>
          <name_xlate lang="en">Intel vxs Driver for Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel vxsドライバーfor Windows Server 2025</alt_name_xlate>
          <alt_name_xlate lang="en">Intel vxs Driver for Windows Server 2025</alt_name_xlate>
        </alt_name>
        <version value="2.3.7.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en"/>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="37"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているIntel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the vxs driver for Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>このドライバーではホストドライバーバージョン1.4.73.0以降が必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This driver requires host driver version 1.4.73.0 or later.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="400"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="vxs.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727">
              <sw_key_expectedpath>%systemroot%\System32\DriverStore\FileRepository\vxs.inf_amd64_d6120d6ae1cc028c</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073018.exe</filename>
        <component_config/>
        <files>
          <file size="834KB" bytes="854568" date_modified="2026-09-02T03:51:16" md5sum="a18e960d0646b8e5c243621741a71402" sha1sum="c1d6729f645838262619e97809d83e621d9f3997" sha256sum="4508c69230dcaaf8f7a0db35d2d3fb4180bfcdf242d149f227536904d9a59482" sha512sum="2fb89cbd2df72979110ccf7d88563336a435ba9644353dcde75ef2f977b3267b0326b3d13fd0c9d95250f2ffe0c46cd6fbd2f210493e426a822502f51d5694a7">
            <name>cp073018.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073018.exe</url>
            <file_list>
              <file>cp073018.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>nicdrvr.dll</file>
              <file>vxs.cat</file>
              <file>vxs.inf</file>
              <file>vxs.sys</file>
              <file>vxsmsg.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="8fe22752c5324386870794853904b4ba">
      <product_version>
        <id product="8fe22752c5324386870794853904b4ba" version="ef17a1d5308f446b885feeefb11179c9" lucid_version="isut.windows_64@6.9.0.0__sc-windows_en"/>
        <different>changed</different>
        <build number="20"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Integrated Smart Update Tools for Windows x64</name_xlate>
          <name_xlate lang="en">Integrated Smart Update Tools for Windows x64</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Integrated Smart Update Tools for Windows</alt_name_xlate>
          <alt_name_xlate lang="en">Integrated Smart Update Tools for Windows</alt_name_xlate>
        </alt_name>
        <version value="6.9.0.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11400032">
          <category_xlate lang="ja">アプリケーション - システム マネジメント</category_xlate>
          <category_xlate lang="en">Application - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="08" day="31" hour="11" minute="29" second="31"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>前提条件の詳細については、『<a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25">iSUTリリースノート</a>』をご覧ください。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>For prerequisite information, please see the <a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25">iSUT Release Notes</a>.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<ol>
	<li>Smartコンポーネント (cpxxxxxx.exe)ファイルをサーバー上のソフトウェアをインストールしたいローカルディレクトリにダウンロードします。</li>
	<li>ディレクトリに移動します。</li>
	<li>.exeファイルをダブルクリックすることで実行します。ダイアログボックスが表示されます。</li>
	<li>インストールボタンをクリックしてSmart Update Toolsをインストールします。</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<ol>
	<li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>
	<li>Change to the directory.</li>
	<li>Run the .exe file by double-clicking it. A dialog box will display.</li>
	<li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">027F</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">027F</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">102B</supported_device_data>
                <supported_device_data name="dev">053A</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04bd</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="5000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="sut.exe" guid="20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b">
              <sw_key_expectedpath>%ProgramFiles%\SUT\bin</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072870.exe</filename>
        <component_config>
          <configuration short_name="sut.win" lang="ja">
            <parameter name="PollingIntervalInMinutes">
              <depends>
                <dependent name="" value=""/>
              </depends>
              <user_prompt>
	Enter Polling interval in minutes. Minimum 5 minutes Maximum 1440 minutes.  
  </user_prompt>
              <default value="5"/>
              <output type="file_variable" filename="sut_cfg.dat" value="5" encrypt="0"/>
              <requirements>
                <required_for_installation value="NO"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>12</maximum_length>
                  <acceptable_characters>
		0-9
	  </acceptable_characters>
                  <required_format>
		*
	  </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
            </parameter>
            <parameter name="Mode">
              <user_prompt>
        Mode in which SUT runs. 
      </user_prompt>
              <default value="AutoDeploy;AutoStage;AutoDeployReboot;OnDemand"/>
              <output type="file_variable" filename="sut_cfg.dat" value="OnDemand" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>24</maximum_length>
                  <acceptable_characters>
            * 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
            <parameter name="StagingDirectory">
              <user_prompt>
        Enter the directory where the staging has to be done. The default path for staging directory in Windows is %localappdata%/sut/stagingdirectory.  The default path for staging directory in Linux is /var/tmp/sut/stagingdirectory.
      </user_prompt>
              <default value=""/>
              <output type="file_variable" filename="sut_cfg.dat" value="" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>255</maximum_length>
                  <acceptable_characters>
            0..9A..Z;a..z;-/ 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
          </configuration>
          <configuration short_name="sut.win" lang="en">
            <parameter name="PollingIntervalInMinutes">
              <depends>
                <dependent name="" value=""/>
              </depends>
              <user_prompt>
	Enter Polling interval in minutes. Minimum 5 minutes Maximum 1440 minutes. 
  </user_prompt>
              <default value="5"/>
              <output type="file_variable" filename="sut_cfg.dat" value="5" encrypt="0"/>
              <requirements>
                <required_for_installation value="NO"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>12</maximum_length>
                  <acceptable_characters>
		0-9
	  </acceptable_characters>
                  <required_format>
		*
	  </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
            </parameter>
            <parameter name="Mode">
              <user_prompt>
        Mode in which SUT runs. 
      </user_prompt>
              <default value="AutoDeploy;AutoStage;AutoDeployReboot;OnDemand"/>
              <output type="file_variable" filename="sut_cfg.dat" value="OnDemand" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>24</maximum_length>
                  <acceptable_characters>
            * 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
            <parameter name="StagingDirectory">
              <user_prompt>
        Enter the directory where the staging has to be done. The default path for staging directory in Windows is %localappdata%/sut/stagingdirectory.  The default path for staging directory in Linux is /var/tmp/sut/stagingdirectory.
      </user_prompt>
              <default value=""/>
              <output type="file_variable" filename="sut_cfg.dat" value="" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>255</maximum_length>
                  <acceptable_characters>
            0..9A..Z;a..z;-/ 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
          </configuration>
        </component_config>
        <files>
          <file size="26MB" bytes="27619664" date_modified="2026-09-10T14:19:43" md5sum="6f655a505d717dfd9583e75d49d679b4" sha1sum="4a5190e8b3f7eb6edbb5c8462c25fa9674b5be2f" sha256sum="5a115428a6087e484b2125f2e2cc928e46d26cc1986cd76bf57d2d94d4e12ccc" sha512sum="79c084622ad5ec7d3f17493ee356c4e9c41cb2a5384759416757b1d0671543b78084b6b8732b967a57836f040d0ae27fff6dc0bed84dc66692c0b5c984c0132a">
            <name>cp072870.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072870.exe</url>
            <file_list>
              <file>CHIF/</file>
              <file>CHIF/X64/</file>
              <file>cp069672.exe</file>
              <file>cp069674.exe</file>
              <file>cp069676.exe</file>
              <file>cp069698.exe</file>
              <file>cp069722.exe</file>
              <file>cp069724.exe</file>
              <file>cp072870.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>HPSUT/</file>
              <file>HPSUT/X64/</file>
              <file>install.xml</file>
              <file>multisetup.dll</file>
              <file>sut.msi</file>
              <file>sutinstaller.exe</file>
              <file>sut_cfg_default.dat</file>
              <file>sut_config_en.xml</file>
              <file>sut_config_ja.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="12fde8c399d84c32a67ace450c8220cd">
      <product_version>
        <id product="12fde8c399d84c32a67ace450c8220cd" version="5d4d7a5ef47a4ee293c5059f768b4c14" lucid_version="A72.fwpkg@1.10_09-24-2026__fwpkg-sys_en"/>
        <different>new</different>
        <build number="894"/>
        <type id="universal-fw-sys"/>
        <name>
          <name_xlate lang="ja">ROM Flash Universal Firmware Package - HPE ProLiant DL525 Gen13 Servers (A72)</name_xlate>
          <name_xlate lang="en">ROM Flash Universal Firmware Package - HPE ProLiant DL525 Gen13 Servers (A72)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE ProLiant DL525 Gen13</alt_name_xlate>
          <alt_name_xlate lang="en">HPE ProLiant DL525 Gen13</alt_name_xlate>
        </alt_name>
        <version value="1.10_09-24-2026" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems/>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="1200212">
          <category_xlate lang="ja">BIOS - System ROM</category_xlate>
          <category_xlate lang="en">BIOS - System ROM</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2025" month="10" day="17" hour="05" minute="07" second="57"/>
        <description>
          <description_xlate lang="ja"><![CDATA[	
This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[	
This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO8_IP_Address&gt; -u &lt;iLO8_username&gt; -p &lt;iLO8_password&gt;</em></strong></p>

<p>Place the json file in the same folder as the fwpkg file.<br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO8_IP_Address&gt; -u &lt;iLO8_username&gt; -p &lt;iLO8_password&gt;</em></strong></p>

<p>Place the json file in the same folder as the fwpkg file.<br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices/>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>300</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="A72" guid="">
              <sw_key_expectedpath>firmware:system</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>A72_1.10_09_24_2026.fwpkg</filename>
        <component_config/>
        <files>
          <file size="64MB" bytes="67135002" date_modified="2026-09-24T05:50:50" md5sum="79bc7d50f0f0907504eeed13f0980f68" sha1sum="f04323dd17f3d5703d62868f470430bc32619163" sha256sum="13830ca3adff0fe1df2e1bb635b9daadf9cf58a7bea8ce8d15991cf203c7fb87" sha512sum="4bf83df1a98e30a8775256a6e08f1699b1408088a849204fd900e0b7be76d3ff7c75a7e8bd60fd974053a4607f7fd17adfc54ad95c2975a3dd5dbfc08bbcc208">
            <name>A72_1.10_09_24_2026.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/A72_1.10_09_24_2026.fwpkg</url>
            <file_list>
              <file>A72_1.10_09_24_2026.signed.flash</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>aa148d2e-6e09-453e-bc6f-63baa5f5ccc4</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>System BIOS - A72</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>A72_1.10_09_24_2026.signed.flash</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>00000000-0000-0000-0000-000000000290</Target>
              <Version>v1.10 (09/24/2026)</Version>
            </Device>
            <Device>
              <DeviceName>System BIOS - A72</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>A72_1.10_09_24_2026.signed.flash</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>00000000-0000-0000-0000-0000000002a8</Target>
              <Version>v1.10 (09/24/2026)</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="dcff0c4699e341cf85f18eb94d85147c">
      <product_version>
        <id product="dcff0c4699e341cf85f18eb94d85147c" version="feb9a0fa256449f3974850859b8de2ee" lucid_version="tg3.rhel9@3.140b-1__pubsw-linux_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9</alt_name_xlate>
        </alt_name>
        <version value="3.140b-1" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 9.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>インストールのノートについてREADMEをダウンロードします。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download README for installation notes.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1665</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22E8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">1786</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">169D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">3383</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159C</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-tg3" guid="20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-tg3" guid="20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-tg3-3.140b-1.rhel9u7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="160KB" bytes="164026" date_modified="2026-09-03T03:41:21" md5sum="f1d8cda6808c6b06be95f99e97c05f4c" sha1sum="9ea9509a2e6594a961cc73a64f34329ae2e2aad9" sha256sum="1bdf1860dca011080cc76a2911c5a926b76955a3db469ddf8e5ff9e69fdc2c13" sha512sum="ce5e70b3ea78c08f556034a4ef9a589aa5af54a252e82e8f8e0efd3b3e054d79f653ca35cb6cbee65bcc0959cb9afbbff4bf5caeaa6c70ec411c411c1cd2b132" version="3.140b" release="1.rhel9u8">
            <name>kmod-tg3-3.140b-1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-tg3-3.140b-1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/tg3.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/tg3</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/tg3/tg3.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/f4</file>
              <file>./usr/lib/.build-id/f4/2ce2504eb948ce3f7f81db28d36dd059e8f653</file>
              <file>./usr/share/smartupdate/kmod-tg3/component.xml</file>
            </file_list>
          </file>
          <file size="161KB" bytes="165210" date_modified="2026-09-03T03:37:07" md5sum="f0975ba735721e6c1fd7b49c2a0a01ca" sha1sum="45c0510ea6f3977f6e9b8ca8c5b7189272a7d196" sha256sum="b6395da4186a9ba366debe3b85d1b075ec8ece892774ad60045d850bb1c3e2bf" sha512sum="1e3281085c286757732e7e926ea305eed75bff35451008a7d0bfaa74fbad7f07652f800c7de1e6f4a96bbc857b1c001791badafbf3afb3a52855e2f26c0a28a9" version="3.140b" release="1.rhel9u7">
            <name>kmod-tg3-3.140b-1.rhel9u7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-tg3-3.140b-1.rhel9u7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/tg3.conf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3/tg3.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/d3</file>
              <file>./usr/lib/.build-id/d3/f876496795b4aa1cdb05e5d14cfeb0bb1fbc75</file>
              <file>./usr/share/smartupdate/kmod-tg3/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="be42e2211b11406e90471c520058561b">
      <product_version>
        <id product="be42e2211b11406e90471c520058561b" version="6e1460f5409f42418f4057f9a9a6977a" lucid_version="FWPKG_MV003200LYJKH_MV006400LYJKK_VV007680LYJKF@HPK4(B)__fwpkg-generic_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ユニバーサルファームウェアパッケージforドライブ - MV003200LYJKH、MV006400LYJKK、VV007680LYJKF、VV015360LYXMT</name_xlate>
          <name_xlate lang="en">Universal Firmware Package for Drives - MV003200LYJKH, MV006400LYJKK, VV007680LYJKF and VV015360LYXMT</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">ユニバーサルファームウェアパッケージforドライブ - MV003200LYJKH、MV006400LYJKK、VV007680LYJKF、VV015360LYXMT</alt_name_xlate>
          <alt_name_xlate lang="en">Universal Firmware Package for Drives - MV003200LYJKH, MV006400LYJKK, VV007680LYJKF, VV015360LYXMT</alt_name_xlate>
        </alt_name>
        <version value="HPK4" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems/>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900357">
          <category_xlate lang="ja">Firmware - PCIe NVMe Storage Disk</category_xlate>
          <category_xlate lang="en">Firmware - PCIe NVMe Storage Disk</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="30" hour="03" minute="11" second="37"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージは、次のドライブモデルのファームウェアを提供します：MV003200LYJKH、MV006400LYJKK、VV007680LYJKFおよびVV015360LYXMT]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package provides firmware for the following drive models: MV003200LYJKH, MV006400LYJKK, VV007680LYJKF and VV015360LYXMT]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p>ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p>リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li>
	<p><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3. iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p><strong>Release Version and/or Date:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />
<strong>Last Recommended or Critical Version:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />
<strong>Previous Version of Firmware:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />
<strong>Enhancements/New Features:</strong></p>

<ul>
	<li>Add dual-signing support.</li>
</ul>

<p><strong>Problems Fixed:</strong></p>

<ul>
	<li>Regular FW maintenance release for sanitize, DRAM,DMA transfer and log page fix.</li>
</ul>

<p><strong>Known Issues:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p><strong>Release Version and/or Date:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />
<strong>Last Recommended or Critical Version:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />
<strong>Previous Version of Firmware:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />
<strong>Enhancements/New Features:</strong></p>

<ul>
	<li>Add dual-signing support.</li>
</ul>

<p><strong>Problems Fixed:</strong></p>

<ul>
	<li>Regular FW maintenance release for sanitize, DRAM,DMA transfer and log page fix.</li>
</ul>

<p><strong>Known Issues:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="nvme">
                <supported_device_data name="id">MV003200LYJKH</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="nvme">
                <supported_device_data name="id">MV006400LYJKK</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="nvme">
                <supported_device_data name="id">VV007680LYJKF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="nvme">
                <supported_device_data name="id">VV015360LYXMT</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="5000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Environment Dependent">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot may be required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>300</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="MV003200LYJKH" guid="">
              <sw_key_expectedpath>firmware:sd:nvme</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="MV006400LYJKK" guid="">
              <sw_key_expectedpath>firmware:sd:nvme</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="VV007680LYJKF" guid="">
              <sw_key_expectedpath>firmware:sd:nvme</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="VV015360LYXMT" guid="">
              <sw_key_expectedpath>firmware:sd:nvme</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>Kioxia_CM7AEF_KACM7AEFHPK4.fwpkg</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2524391" date_modified="2026-09-15T06:55:17" md5sum="4cf52f6419f9bbc7c27d293f8692adf6" sha1sum="369c8971d9e2d7a574f64a2fab790061aeb5cc92" sha256sum="3e462969df6db12023d6778cf7ea91e977cb1a456e7363bb0676cc23d58ea37c" sha512sum="4e313f97d0648236194fdf542308e5f1bfbb6adc673270721cfb3a7a7435b45e67f039fd23deda0f25b7054315da0eabd9975eba6f71fb16c7b45ae4cccd43f0">
            <name>Kioxia_CM7AEF_KACM7AEFHPK4.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/Kioxia_CM7AEF_KACM7AEFHPK4.fwpkg</url>
            <file_list>
              <file>Kioxia_CM7AEF_KACM7AEFHPK4.HPb</file>
              <file>Kioxia_CM7AEF_KACM7AEFHPK4.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>f6de0320-2e0f-489a-b238-6dd8ae7c3811</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Kioxia-CM7AEF-NVMe</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>Kioxia_CM7AEF_KACM7AEFHPK4.HPb</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>4d2340a5-3056-3330-3230-304c594a4b48</Target>
              <Version>HPK4</Version>
            </Device>
            <Device>
              <DeviceName>Kioxia-CM7AEF-NVMe</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>Kioxia_CM7AEF_KACM7AEFHPK4.HPb</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>4d2340a5-3056-3630-3430-304c594a4b4b</Target>
              <Version>HPK4</Version>
            </Device>
            <Device>
              <DeviceName>Kioxia-CM7AEF-NVMe</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>Kioxia_CM7AEF_KACM7AEFHPK4.HPb</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>562340a5-3056-3730-3638-304c594a4b46</Target>
              <Version>HPK4</Version>
            </Device>
            <Device>
              <DeviceName>Kioxia-CM7AEF-NVMe</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>Kioxia_CM7AEF_KACM7AEFHPK4.HPb</FileName>
                <InstallDurationSec>300</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>562340a5-3056-3531-3336-304c59584d54</Target>
              <Version>HPK4</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="1174220fe8354722a040071980d1eb37">
      <product_version>
        <id product="1174220fe8354722a040071980d1eb37" version="a087dcb6303a470398fff6a5fc1c5cb5" lucid_version="mellanox_winof2.w2k25@26.4.27095.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="5"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Mellanox WinOF2ドライバーfor Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">Mellanox WinOF2 Driver for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Mellanox WinOF2ドライバーfor Microsoft Windows Server 2025</alt_name_xlate>
          <alt_name_xlate lang="en">Mellanox WinOF2 Driver for Microsoft Windows Server 2025</alt_name_xlate>
        </alt_name>
        <version value="26.4.27095.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="01" hour="08" minute="15" second="38"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントパッケージは、Mellanox Ethernet NIC for Microsoft Windows Server 2025のドライバーを含みます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the driver for Mellanox Ethernet NICs for Microsoft Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0052</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0117</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0102</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0047</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0040</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1018</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0117</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101e</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0040</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101e</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1016</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0102</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1016</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0047</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1018</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1018</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0052</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101E</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101E</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="1000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="mlx5.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073436.exe</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2491096" date_modified="2026-09-02T05:12:21" md5sum="f750f8d45e5ca6c7b0e2f42241650c03" sha1sum="04c47aaa9456a23722ea5fa0faf0a16972c9dfc6" sha256sum="decf6f4326d552563bd843c4319e4df3537e14bc54b19bb77299ba7fa3927361" sha512sum="bd364e5ecf85e64fff9e5c57e7e03783186f6337697160d7b0e9d96e40a3a45cc7ae4978d8fc051497682719454fab57ccae5079a6bee2f9052bb166d06a122d">
            <name>cp073436.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073436.exe</url>
            <file_list>
              <file>cp073436.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>mlx5.cat</file>
              <file>mlx5.inf</file>
              <file>mlx5.sys</file>
              <file>mlx5ui.dll</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="854591aa471148a8b13f9c435ab181af">
      <product_version>
        <id product="854591aa471148a8b13f9c435ab181af" version="93922329b20f4bc5879e77cd0e039620" lucid_version="tg3.sles16@3.140b-2__pubsw-linux_en"/>
        <different>new</different>
        <build number="2"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="3.140b-2" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 16で動作するHPE Broadcom NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 16.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>インストール手順についてのREADMEをダウンロードします。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download README for installation instructions.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1665</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22E8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">1786</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">169D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">3383</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159C</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="tg3-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="159KB" bytes="163184" date_modified="2026-09-03T02:25:20" md5sum="132732536503aef9b2b6a971e4595014" sha1sum="45360ff8a6c4c00e5bf63068b64318600d54a291" sha256sum="b00471dc6dc78d6761c172a2de9c148ecb1bb16be52cb42d82b1279bd11a1301" sha512sum="9be6292ae36ca76aef0c136b5e8d40741fb35d17177096731beb36192a6057687b9ad38f0af12c166a3f659370bcc956817d81fa9ad867143d6a99e4b1e1d0a3" version="3.140b_k6.12.0_160000.5" release="2.sles16sp0">
            <name>tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./usr/lib/modules/6.12.0-160000.5-default</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/tg3.ko</file>
              <file>./usr/share/smartupdate/tg3-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="6e47868a4c52411285405d34ddf4456a">
      <product_version>
        <id product="6e47868a4c52411285405d34ddf4456a" version="1e6a74e236a048cebc630bd8f5c4db3c" lucid_version="Gen10P_Gen11_MR_Controller.sles16.x86_64.rpm@07.738.06.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16</name_xlate>
          <name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="07.738.06.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">LSI Logic Corporation</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">LSI Logic Corporation</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300214">
          <category_xlate lang="ja">ドライバ - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Driver - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="14"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for SUSE LINUX Enterprise Server 16 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for SUSE LINUX Enterprise Server 16 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles16spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
To upgrade the driver, type the following command:<br />
# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles16spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles16spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
To upgrade the driver, type the following command:<br />
# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles16spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="lsi-megaraid_sas-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="911KB" bytes="933646" date_modified="2026-09-03T11:21:21" md5sum="cc94ec880ff026691b936d2de5686809" sha1sum="177bf8dbb2fa38afda048a82c53914d71fa2db10" sha256sum="709efa855e8430161d82731465bf0a9539d1dd14dde6ddd4b6442eeea0f29bdf" sha512sum="f1c50e14df1405ee8691b0d9d57d5486cca493470814c935f27e2b98c487133d8a5f3c70ad8b3945150ed304e42cd8dbc5173d31f497aeadd2c3ffc90d03ea57" version="07.738.06.0_sles16sp0" release="1">
            <name>lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.rpm</url>
            <file_list>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/b7</file>
              <file>./usr/lib/.build-id/b7/5c1aa60393774c36a324a16221828184c363d9</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/megaraid_sas.ko</file>
              <file>./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="8796bf21e8204a0da4179cfbcd105e85">
      <product_version>
        <id product="8796bf21e8204a0da4179cfbcd105e85" version="1c34eb23d4374bd59fe1dc78ee67144c" lucid_version="Gen10P_Gen11_MR_Controller.rhel9.x86_64.rpm@07.738.06.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MR416i-p、 MR216i-p、 MR416i-a、 MR216i-a Gen10 plusコントローラーおよびMR416i-p、 MR416i-o、 MR216i-o、 MR408i-o、 MR216i-p、 MR408i-p Gen11コントローラードライバーfor 64ビットRed Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p、 MR216i-p、 MR416i-a、 MR216i-a Gen10 plusコントローラーおよびMR416i-p、 MR416i-o、 MR216i-o、 MR408i-o、 MR216i-p、 MR408i-p Gen11コントローラードライバーfor 64ビットRed Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controlers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9</alt_name_xlate>
        </alt_name>
        <version value="07.738.06.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300214">
          <category_xlate lang="ja">ドライバ - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Driver - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="19"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このRPMを使用して、HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusコントローラーおよびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラーを有効にする、64ビットRed Hat Enterprise Linux 9用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 9 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>ドライバーをインストールするには、次のコマンドを入力します。<br />
# rpm --Uvh --oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel9uX.x86_64.rpm (X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します)</p>

<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel9uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>

<p>A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-megaraid_sas" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-megaraid_sas" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="140KB" bytes="144122" date_modified="2026-09-03T11:55:15" md5sum="a7015a342f7b646db2d2d532912a0eb6" sha1sum="05af77e1bbcce1ff3434c6401b592a6422f08843" sha256sum="dc4be56fffd3fc3da8ebc75e99d9750e39b329de74864aea36788453ebcb2bea" sha512sum="e4c98cb621cb4fcf098ba6fc3b95570d77185cbd9436cee8f396415e625b07b57e1a7f1b1ee46fd34f4dd2788aee41f0a9f1330ebe4473fbfdc79336fbf92c54" version="07.738.06.0_rhel9u8" release="1">
            <name>kmod-megaraid_sas-07.738.06.0_rhel9u8-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-megaraid_sas-07.738.06.0_rhel9u8-1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/megaraid_sas.conf</file>
              <file>./etc/dracut.conf.d/megaraid_sas.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/megaraid_sas</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/megaraid_sas/megaraid_sas.ko</file>
              <file>./usr/share/smartupdate/kmod-megaraid_sas/component.xml</file>
            </file_list>
          </file>
          <file size="144KB" bytes="147560" date_modified="2026-09-03T11:47:39" md5sum="182abffd19347228794eaa40c36c1d53" sha1sum="fd5853c0a278b9785de538085264cdba1005c302" sha256sum="5283b7771683b058ddb82a816476d55154bdfc3db8a509be00f16d2a33d3b69b" sha512sum="0d49a2f4bb6d00149ac5a4b7d73700069e6514f9d73cce900789f3b9cfa0a6328c5fb00e4a88c0f880bc4b0b3805c355060e93342c3fa31f04fa2388c4106e3d" version="07.738.06.0_rhel9u7" release="1">
            <name>kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/megaraid_sas.conf</file>
              <file>./etc/dracut.conf.d/megaraid_sas.conf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas/megaraid_sas.ko</file>
              <file>./usr/share/smartupdate/kmod-megaraid_sas/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="049ca173304042ae9feccac41164d4f3">
      <product_version>
        <id product="049ca173304042ae9feccac41164d4f3" version="0a6e2d8d68a4478e9d6b10e9a56bfa59" lucid_version="matrox.G200eH5.win2025.x64@9.15.1.271(F)__sc-windows_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Matrox G200eH3ビデオコントローラードライバーfor Microsoft Windows Server 2022および2025</name_xlate>
          <name_xlate lang="en">Matrox G200eH5 Video Controller Driver for Microsoft Windows Server 2022 and 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Matrox G200eH5ビデオコントローラードライバーfor Microsoft Windows</alt_name_xlate>
          <alt_name_xlate lang="en">Matrox G200eH5 Video Controller Driver for Microsoft Windows</alt_name_xlate>
        </alt_name>
        <version value="9.15.1.271" revision="F" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300060">
          <category_xlate lang="ja">ドライバ - ビデオ</category_xlate>
          <category_xlate lang="en">Driver - Video</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="08" day="30" hour="08" minute="19" second="02"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントは、Matrox G200eH5ビデオコントローラー対応の高度なビデオ機能を提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This component provides advanced video support for the Matrox G200eH5 video controller.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>
<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>
<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>
<P>Select "Install" to start extracting to a temporary location on the hard drive.</P>
<P>Click the "Install" button to perform the driver installation.</P>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows 10 (64bit, version 1803 &amp; older)"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" name="Microsoft Windows 10 (64bit, version 1809 &amp; later)"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">102B</supported_device_data>
                <supported_device_data name="dev">053A</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">102B</supported_device_data>
                <supported_device_data name="dev">053A</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04bd</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <supported_platforms>
            <supported_platform rom="U74"/>
            <supported_platform rom="U84"/>
            <supported_platform rom="U68"/>
            <supported_platform rom="U71"/>
            <supported_platform rom="I46"/>
            <supported_platform rom="A66"/>
            <supported_platform rom="U72"/>
            <supported_platform rom="A72"/>
            <supported_platform rom="U83"/>
          </supported_platforms>
          <required_diskspace size_kb="10000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>60</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="MxG2hDO64.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072860.exe</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1639112" date_modified="2026-09-14T03:27:13" md5sum="2d7f5c0ed5a27b176dbbd6131cfc57b0" sha1sum="9b7ead6566c8ef4dc0b96b29adf25d77aaea6175" sha256sum="ec26910b29b4eae1c59d843beede4d06e37186973875608242377d88d6c40dd3" sha512sum="bb7ca1207a889d72a505d8a0c7d838c41dbf3bec1ac28ddbceae3825882aa97a358324e43b1c945a252e678a1283b7a578e28557027f37d419cc676401237cd3">
            <name>cp072860.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072860.exe</url>
            <file_list>
              <file>cp072860.xml</file>
              <file>cpqsetup.exe</file>
              <file>generic.dll</file>
              <file>install.xml</file>
              <file>Matrox.WddmUninstaller.exe</file>
              <file>mxg200eh.cat</file>
              <file>MxG200eH.inf</file>
              <file>MxG2hDO64.sys</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="2c6711088bca48d8a5963e48aa925230">
      <product_version>
        <id product="2c6711088bca48d8a5963e48aa925230" version="1e32b2d5853b43fb9f840cd6f5ab7fde" lucid_version="nicfwpkg_bcm_bcm5719ocp@20.38.51__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom NX1ファームウェアパッケージfor BCM5719 OCP3アダプター</name_xlate>
          <name_xlate lang="en">Broadcom NX1 Firmware Package for BCM5719 OCP3 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom NX1ファームウェアパッケージfor BCM5719 OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom NX1 Firmware Package for BCM5719 OCP3 adapter</alt_name_xlate>
        </alt_name>
        <version value="20.38.51" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NX1 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NX1 Gigabit Ethernet NICs firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してFWPKGをフラッシュします</p>

<ol>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li><a href="https://support.hpe.com/">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</li>
	<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</li>
</ul>

<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p> </p>

<p>2. iLO GUIからのフラッシュ</p>

<ol>
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>サポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIで、[ファームウェア] に移動し、[iLOレポジトリにアップロード] を選択します。ファームウェアファイルを参照して、iLOレポジトリにアップロードします。</li>
	<li>iLOレポジトリで、メニューボタンをクリックして「インストール」を選択します。これにより、ファームウェアコンポーネントがインストールキューに追加されます。</li>
	<li>コンポーネントはインストールキューに追加されました。</li>
	<li>ファームウェアコンポーネントがインストールキューに存在する場合は、そのステータスを確認します。ステータスは「保留中」と表示されます。</li>
	<li>サーバーを再起動し、POSTページでファームウェアがフラッシュされているかどうかを確認します。</li>
	<li>ファームウェアのフラッシュと再起動後、インストールキューに戻り、ファームウェアコンポーネントのステータスが「完了」と表示されていることを確認します。</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the FWPKG using any below methods</p>

<ol>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO&nbsp;GUI</li>
</ol>

<p>1. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately.</p>

<p>&nbsp;</p>

<p>2.&nbsp;Flash from iLO&nbsp;GUI</p>

<ol>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the&nbsp;supported adapter is present in the server</li>
	<li>In the iLO GUI, navigate to Firmware, then select Upload to iLO Repository. Browse for the firmware file and upload it to the iLO repository.</li>
	<li>In the iLO Repository, click the menu button and select Install. This will add the firmware component to the installation queue.</li>
	<li>Go to the installation queue and verify that the firmware component has been added.</li>
	<li>If the firmware component is present in the installation queue, check its status, which should show as &quot;Pending&quot;.</li>
	<li>Reboot the server and verify on the POST page whether the firmware is being flashed.</li>
	<li>After the firmware flash and reboot, return to the installation queue and confirm that the firmware component status shows as &quot;Complete&quot;.</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains combo image v20.38.51&nbsp;with the following firmware versions:</p>

<table border="1" cellpadding="2">
	<tbody>
		<tr>
			<td><strong>NIC</strong></td>
			<td><strong>Boot Code Version</strong></td>
			<td><strong>PXE Version</strong></td>
			<td><strong>NCSI Version</strong></td>
			<td><strong>UEFI Version</strong></td>
		</tr>
		<tr>
			<td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td>
			<td>1.68</td>
			<td>21.6.4</td>
			<td>1.5.77</td>
			<td>21.6.113</td>
		</tr>
	</tbody>
</table>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains combo image v20.38.51&nbsp;with the following firmware versions:</p>

<table border="1" cellpadding="2">
	<tbody>
		<tr>
			<td><strong>NIC</strong></td>
			<td><strong>Boot Code Version</strong></td>
			<td><strong>PXE Version</strong></td>
			<td><strong>NCSI Version</strong></td>
			<td><strong>UEFI Version</strong></td>
		</tr>
		<tr>
			<td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td>
			<td>1.68</td>
			<td>21.6.4</td>
			<td>1.5.77</td>
			<td>21.6.113</td>
		</tr>
	</tbody>
</table>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="NIC_NX1_5719OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM5719N1905HC-4x1G-20.38.51.fwpkg</filename>
        <component_config/>
        <files>
          <file size="548KB" bytes="561203" date_modified="2026-08-20T05:04:20" md5sum="7e09dff67977be0e56f65e6cf03c2e10" sha1sum="f0ade2f42598bee92bc96cbb5226d688e9f36ebd" sha256sum="778590ebe94c1e5542467f0a899917048e8d920fec251587309515dad147e046" sha512sum="b2549ebd2764de313199a0b11146bf0eb81e6c7a5fdc4251d4bfb8e4025fd514709e5f1ee69486e2132117c9c8945fefd2a9461e273ba94779d28bf02ec8f9a0">
            <name>BCM5719N1905HC-4x1G-20.38.51.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM5719N1905HC-4x1G-20.38.51.fwpkg</url>
            <file_list>
              <file>BCM5719N1905HC-4x1G-20.38.51.HPb</file>
              <file>BCM5719N1905HC-4x1G-20.38.51.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom BCM5719 OCP3 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM5719N1905HC-4x1G-20.38.51.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-165714e41590</Target>
              <Version>20.38.51</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="68526791858d42b69b174ffed2a35fa0">
      <product_version>
        <id product="68526791858d42b69b174ffed2a35fa0" version="378881ba42164b2c8f120d413c0ec2dc" lucid_version="amsd_sles16@5.1.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="17"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">ams_sles16</alt_name_xlate>
          <alt_name_xlate lang="en">ams_sles16</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out (iLO 5 and above) Embedded Health and Alerting.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out (iLO 5 and above) Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above,&nbsp;service providing SNMP support.</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above,&nbsp;service providing SNMP support.</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd-5.1.0-2197.8.sles16.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="11MB" bytes="11671332" date_modified="2026-09-30T09:12:43" md5sum="6e3988941498986eaa0849377f503f62" sha1sum="0e44742ee35d5fe589c845793b62c37555d2821b" sha256sum="4aed597a11a315e8738ad9138ba2bf05844cddb084fa789afa7379b4871f593d" sha512sum="660e931fdd2d7984d32103b20a4ffc6c1d501344c46cdb185a10cd23adee74d9351c356fbae30b340e043ffe28072a42cfcb055fe20f98c79439aa1807fdcc76" version="5.1.0" release="2197.8.sles16">
            <name>amsd-5.1.0-2197.8.sles16.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd-5.1.0-2197.8.sles16.x86_64.rpm</url>
            <file_list>
              <file>./etc/sysconfig/ahslog</file>
              <file>./etc/sysconfig/amsd</file>
              <file>./etc/sysconfig/amsd_rev</file>
              <file>./etc/sysconfig/cpqFca</file>
              <file>./etc/sysconfig/cpqFca_rev</file>
              <file>./etc/sysconfig/cpqIde</file>
              <file>./etc/sysconfig/cpqIde_rev</file>
              <file>./etc/sysconfig/cpqScsi</file>
              <file>./etc/sysconfig/cpqScsi_rev</file>
              <file>./etc/sysconfig/cpqiScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi_rev</file>
              <file>./etc/sysconfig/smad</file>
              <file>./etc/sysconfig/smad_rev</file>
              <file>./opt/amsd</file>
              <file>./opt/amsd/amsd.license</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/cpqiScsi</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/2c</file>
              <file>./usr/lib/.build-id/2c/4201ab35520fc89bb00bf09114c38294520b7d</file>
              <file>./usr/lib/.build-id/3b</file>
              <file>./usr/lib/.build-id/3b/49f3bf8a6619e58d59c7d5f625b091f07a74bf</file>
              <file>./usr/lib/.build-id/44</file>
              <file>./usr/lib/.build-id/44/c20d40d630b11afd35ffd29cd650fbd9f931e6</file>
              <file>./usr/lib/.build-id/44/c20d40d630b11afd35ffd29cd650fbd9f931e6.1</file>
              <file>./usr/lib/.build-id/61</file>
              <file>./usr/lib/.build-id/61/b6e78204bdbb7f0088de92860a15ac5f3e6aba</file>
              <file>./usr/lib/.build-id/88</file>
              <file>./usr/lib/.build-id/88/17ede0c583b84c6d3df8b28f16427197fc3cd0</file>
              <file>./usr/lib/.build-id/88/17ede0c583b84c6d3df8b28f16427197fc3cd0.1</file>
              <file>./usr/lib/.build-id/9a</file>
              <file>./usr/lib/.build-id/9a/e137946aa8bacbd8d9c182abc5646b0b14be73</file>
              <file>./usr/lib/.build-id/9a/e137946aa8bacbd8d9c182abc5646b0b14be73.1</file>
              <file>./usr/lib/.build-id/c0</file>
              <file>./usr/lib/.build-id/c0/880948b88e815dbacb58c65624b292136e3f03</file>
              <file>./usr/lib/.build-id/c0/880948b88e815dbacb58c65624b292136e3f03.1</file>
              <file>./usr/lib/.build-id/e0</file>
              <file>./usr/lib/.build-id/e0/b442cd5cc606699128816e516954d3519739aa</file>
              <file>./usr/lib/.build-id/e0/b442cd5cc606699128816e516954d3519739aa.1</file>
              <file>./usr/lib/.build-id/fa</file>
              <file>./usr/lib/.build-id/fa/9a2272d0e157a735f577a4cc7b78a0bca7c1bd</file>
              <file>./usr/lib/.build-id/fa/9a2272d0e157a735f577a4cc7b78a0bca7c1bd.1</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqFca_rev.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqIde_rev.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./usr/lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./usr/share/man/man8/ahslog.8.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqIde.8.gz</file>
              <file>./usr/share/man/man8/cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/smad.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqFca_rev</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqIde_rev</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqScsi_rev</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/mr_cpqScsi_rev</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="e4d8aaf26a80450db4749aeac2c8ee06">
      <product_version>
        <id product="e4d8aaf26a80450db4749aeac2c8ee06" version="3bc93f14d9ef402887cc726e6c748658" lucid_version="bnxt.sles16@1.10.3-238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="5"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="1.10.3-238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 16で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 16.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="bnxt_en-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ece34fd967">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1434532" date_modified="2026-09-03T03:25:20" md5sum="98774a1cc49e6bc75dd53a1a72d86d80" sha1sum="cb8aaf464a4dbbfe111499e9007ea33f20fdcccc" sha256sum="76aa422b3a8f62aa1c5833700b4d74597f7f277a07d9d6ae79b3537158ac36e8" sha512sum="2ac05f06728c34ea5beba220216763b75585edd902004b036e5fb3e74f572cfa9ae2d1f1498843539994da898fdf3709feac68d409bd0c7de9b02a8694b7a0c3" version="1.10.3_k6.12.0_160000.5" release="238.1.165.0.sles16sp0">
            <name>bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./usr/lib/modules/6.12.0-160000.5-default</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/bnxt_en.ko</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/drivers</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/bnxt_en-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="1ba6abb4e9ff40ab8c8d2a6c0f1a1860">
      <product_version>
        <id product="1ba6abb4e9ff40ab8c8d2a6c0f1a1860" version="f295695a8fa546af80d2d5c908ccd67e" lucid_version="Gen10P_Gen11_StorCLI.ubuntu@007.3811.0300__pubsw-linux_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="12"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10PおよびGen11コントローラー)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10PおよびGen11コントローラー)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)</alt_name_xlate>
        </alt_name>
        <version value="007.3811.0300" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11447">
            <operating_system_xlate>Ubuntu 24.04 LTS</operating_system_xlate>
          </operating_system>
          <operating_system key="11701">
            <operating_system_xlate>Ubuntu 26.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,ja,de,fr,it,es">
          <languages_xlate lang="ja">英語（US）,日本語,ドイツ語,フランス語,イタリア語,スペイン語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese,German,French,Italian,Spanish</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="23"/>
        <description>
          <description_xlate lang="ja"><![CDATA[コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Description:<br />
===========<br />
This is a StorCLI readme file mentioning instructions to use:<br />
&nbsp;&nbsp; &nbsp;1. StorCLI on all the supported operating systems.<br />
&nbsp;&nbsp; &nbsp;2. StorCLI&#39;s JSON Schema files.<br />
&nbsp;&nbsp; &nbsp;3. StorCLI&#39;s logging feature.</p>

<p>Please read before you start using StorCLI executable.</p>

<p>&nbsp;</p>

<p>Privileges:<br />
=========<br />
&nbsp;&nbsp; &nbsp;1. StorCLI should be installed / executed with administrative / root / super user privileges.<br />
&nbsp;&nbsp; &nbsp;2. Installed/Execution location should have Read/Write/Execute permissions.</p>

<p>&nbsp;</p>

<p>Ubuntu:<br />
=======<br />
Installation:&nbsp;&nbsp; &nbsp;&nbsp;<br />
&nbsp;&nbsp; &nbsp;1. Debian package can be installed using following command syntax : sudo dpkg -i &lt;.deb package&gt;<br />
&nbsp;&nbsp; &nbsp;2. Installed debian package can be verified using following command syntax : dpkg -l | grep -i storcli</p>

<p>&nbsp;</p>

<p>Logging:<br />
========&nbsp;<br />
&nbsp;&nbsp; &nbsp;1. While executing StorCLI, Logging is enabled by default.<br />
&nbsp;&nbsp; &nbsp;2. To Turn-off the logging, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to 0.<br />
&nbsp;&nbsp; &nbsp;3. To change the log level, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to any desired log level.<br />
&nbsp;&nbsp; &nbsp;4. In case of application crash, Place the storcliconf.ini in the current directory to capture logs.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Description:<br />
===========<br />
This is a StorCLI readme file mentioning instructions to use:<br />
&nbsp;&nbsp; &nbsp;1. StorCLI on all the supported operating systems.<br />
&nbsp;&nbsp; &nbsp;2. StorCLI&#39;s JSON Schema files.<br />
&nbsp;&nbsp; &nbsp;3. StorCLI&#39;s logging feature.</p>

<p>Please read before you start using StorCLI executable.</p>

<p>&nbsp;</p>

<p>Privileges:<br />
=========<br />
&nbsp;&nbsp; &nbsp;1. StorCLI should be installed / executed with administrative / root / super user privileges.<br />
&nbsp;&nbsp; &nbsp;2. Installed/Execution location should have Read/Write/Execute permissions.</p>

<p>&nbsp;</p>

<p>Ubuntu:<br />
=======<br />
Installation:&nbsp;&nbsp; &nbsp;&nbsp;<br />
&nbsp;&nbsp; &nbsp;1. Debian package can be installed using following command syntax : sudo dpkg -i &lt;.deb package&gt;<br />
&nbsp;&nbsp; &nbsp;2. Installed debian package can be verified using following command syntax : dpkg -l | grep -i storcli</p>

<p>&nbsp;</p>

<p>Logging:<br />
========&nbsp;<br />
&nbsp;&nbsp; &nbsp;1. While executing StorCLI, Logging is enabled by default.<br />
&nbsp;&nbsp; &nbsp;2. To Turn-off the logging, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to 0.<br />
&nbsp;&nbsp; &nbsp;3. To change the log level, Place the storcliconf.ini in the current directory and change the DEBUGLEVEL to any desired log level.<br />
&nbsp;&nbsp; &nbsp;4. In case of application crash, Place the storcliconf.ini in the current directory to capture logs.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="ubuntu2404" major="24" minor="04" sr="OEM" name="Ubuntu 24.04 LTS"/>
            <supported_operating_system platform="ubuntu2204" major="22" minor="04" sr="OEM" name="Ubuntu 22.04 LTS"/>
            <supported_operating_system platform="ubuntu2604" major="26" minor="04" sr="OEM" name="Ubuntu 26.04 LTS"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="storcli" guid="20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be">
              <sw_key_expectedpath>software:deb</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>storcli_007.3811.0300_all.deb</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2329512" date_modified="2026-09-07T06:52:42" md5sum="46e65ece13a9896446d6f2104ba7bfc7" sha1sum="2e14aaea12a1e1cc94d520d224e919316856d6b7" sha256sum="ae5f3d9f6e64e399f71ae0693831b339c00a6c6c0160729d5faf90efcbf49d56" sha512sum="188da0d9fb567e7e76ea1bdf8d59b2b07f0ddc8e0449ff5394f13d8f76c1168b2dafd71ab5ff9210561d5469fe72b66c9fb5233317ac5c21db964f4077146fa0" version="007.3811.0300">
            <name>storcli_007.3811.0300_all.deb</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/storcli_007.3811.0300_all.deb</url>
            <file_list>
              <file>./opt/MegaRAID/storcli/storcli64</file>
              <file>./usr/share/smartupdate/storcli/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="80ea6cb0c7d14159a1a37d37866e5b0c">
      <product_version>
        <id product="80ea6cb0c7d14159a1a37d37866e5b0c" version="80dcff8b31174dceafcb6e57e1c75a60" lucid_version="nicfwpkg_bcme_57412_2p10ocp@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="7"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57412 OCP3アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57412 OCP3 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57412 OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57412 OCP3 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57412 OCP3 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57412OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957412N4120HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1464483" date_modified="2026-09-03T06:44:15" md5sum="24686f816196f48c0e7dded0c1ab5e15" sha1sum="5ede87bf73e63b8f120bdc4df78f5109890c8d04" sha256sum="b8732203dbe8597161d53fe046df9212dfad69f899d26de523b207a89761faa3" sha512sum="c003eb50f036002531584c9ec358b3324d840c1107218afc0ed2bd0a5eb83168020482204fecf9b9aa1a968c61c547922fbbfafafd715336861a619370297bd6">
            <name>BCM238.1.169.0_BCM957412N4120HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957412N4120HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957412N4120HC.HPb</file>
              <file>BCM238.1.169.0_BCM957412N4120HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N4120HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d614e41594</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N4120HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16de14e41594</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N4120HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16eb14e41594</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="9eeb0ff245dd43c78ad42320aad05c3a">
      <product_version>
        <id product="9eeb0ff245dd43c78ad42320aad05c3a" version="fcff21ff9a944665b0611f24325f4749" lucid_version="ixgbe.sles16@6.4.4-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="6.4.4-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="45"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 16で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 16.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ixgbe-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb870faaa">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="441KB" bytes="452438" date_modified="2026-09-02T08:53:21" md5sum="4b7e3f02c558bec9b71ea2753190d36a" sha1sum="e84d11d7a8dff73d0cca57cb27bcfd36c780b3e7" sha256sum="65b9363887ad89f6493054e4081ebaf4141e56e3f422107490cb4aecc0c05691" sha512sum="f6ee464d7c301aa826ebee0b5eb0ca7305613958e05776eec87d0c36a203aa556e9add9e6a54e977d6ca5b23b4d3be82b3583fb3f09ce6b270576bc5c0822a2a" version="6.4.4_k6.12.0_160000.5" release="1.sles16sp0">
            <name>ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbe.ko</file>
              <file>./usr/share/doc/packages/ixgbe-kmp-default</file>
              <file>./usr/share/doc/packages/ixgbe-kmp-default/COPYING</file>
              <file>./usr/share/doc/packages/ixgbe-kmp-default/README</file>
              <file>./usr/share/man/man7/ixgbe.7.gz</file>
              <file>./usr/share/pci.ids.d/pci.ids.ixgbe-kmp-6.4.4</file>
              <file>./usr/share/smartupdate/ixgbe-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="a529a1b0d8b0405f80457239f0d32b29">
      <product_version>
        <id product="a529a1b0d8b0405f80457239f0d32b29" version="d8e855fe894f4c66b04c9f0054ea9ff4" lucid_version="bnxt.rhel10@1.10.3-238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="1.10.3-238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、Red Hat Enterprise Linux 10下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 10.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-bnxt_en" guid="20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-bnxt_en" guid="20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1473855" date_modified="2026-09-03T02:32:35" md5sum="0730cd0fbd456f53cf7bc67ee9642d52" sha1sum="fdbdf7934187530dfa39965103b7f430b4affd87" sha256sum="5d2576906306ea933575c6765957000e488707de8babec34e2f19168379ad6c5" sha512sum="d9fd879fceee31d2185a856968b5e5dad40de5aaa7900565ee1a740b8189abb4462e5b58ae0b7ed8ddef40808092b6742dce0418ba1200990b55b83aec326f31" version="1.10.3" release="238.1.165.0.rhel10u2">
            <name>kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/bnxt_en.conf</file>
              <file>./etc/depmod.d/bnxt_re.conf</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/bnxt_en.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/kmod-bnxt_en/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1475794" date_modified="2026-09-03T02:28:18" md5sum="0b0f3dc477b804ab880c3268a681b30c" sha1sum="2866409631dea3c5eb0c4b66960ce22931d1d56e" sha256sum="552138ced77cfcfb58713cbf7962df2b8714454bc583d037c5e2f5d6c083cd45" sha512sum="d20b9f50b6b78fefe3c8ff0c73fe70117afc848253cc9fb7167fc43470fecc8e6b580cd124e168dbab141b9f6ab845ecbf7984d076e484349f9a4dd4b4598bba" version="1.10.3" release="238.1.165.0.rhel10u1">
            <name>kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/bnxt_en.conf</file>
              <file>./etc/depmod.d/bnxt_re.conf</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/bnxt_en.ko</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/kmod-bnxt_en/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="f753d0d85d5c40278c0a50daf001c162">
      <product_version>
        <id product="f753d0d85d5c40278c0a50daf001c162" version="11a92330c599479883cd800b1baae307" lucid_version="HPE_MR408i-p_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="11"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR408i-p Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR408i-p Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR408i-p Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR408i-p Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="SPP"/>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="41"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR408i-p Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR408i-p Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="04481590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR408i-p_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521143" date_modified="2026-09-21T05:26:17" md5sum="61ef8e1a9470cffa6c870e61b3a5071e" sha1sum="2595d05b4eb435dddaa0796f359936a460241ef9" sha256sum="20fd47a364eedd0363ffcad66da4015f8ed4559560e652fca457e3f984ef34fa" sha512sum="5c016d333bf87e9da352435864a2a869817cd1dd944052f78e96098a27c59b5add50386c1de2501780e9fb1dac15382194156ff236b3b6888c62fe9e8011e4cc">
            <name>HPE_MR408i-p_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR408i-p_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR408i-p_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR408i-p_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR408i-p_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR408i-p_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e215900448</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="8927cfd49bdd4662a4005f15b8eb6847">
      <product_version>
        <id product="8927cfd49bdd4662a4005f15b8eb6847" version="26c168ee6d3341d1a2a1605c63bb5e6e" lucid_version="ubuntu2604amsd@5.1.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="12"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service for Ubuntu 26.04 LTS</name_xlate>
          <name_xlate lang="en">Agentless Management Service for Ubuntu 26.04 LTS</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Agentless Management Service for Ubuntu 26.04 LTS</alt_name_xlate>
          <alt_name_xlate lang="en">Agentless Management Service for Ubuntu 26.04 LTS</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11701">
            <operating_system_xlate>Ubuntu 26.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation method:</strong><br />
&nbsp;<br />
Using dpkg command<br />
To install the package, type:</p>

<ul>
	<li>dpkg -i amsd-&lt;version&gt;.deb</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul>
		<li>dpkg -i amsd-&lt;version&gt;.deb</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul>
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul>
		<li>man amsd</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation method:</strong><br />
&nbsp;<br />
Using dpkg command<br />
To install the package, type:</p>

<ul>
	<li>dpkg -i amsd-&lt;version&gt;.deb</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul>
		<li>dpkg -i amsd-&lt;version&gt;.deb</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul>
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul>
		<li>man amsd</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="ubuntu2604" major="26" minor="04" sr="OEM" name="Ubuntu 26.04 LTS"/>
          </supported_operating_systems>
          <supported_devices/>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:deb</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd_5.1.0-2197.8-ubuntu26_amd64.deb</filename>
        <component_config/>
        <files>
          <file size="8MB" bytes="9166842" date_modified="2026-09-30T14:04:40" md5sum="b5b205c21776ae0d28aa2d6cace263d9" sha1sum="4f845ac7207917477cd196741777286534ec5e76" sha256sum="b7ee90d1af7db1a2eb9f3265af3f66a57e11143ca22fd89323646619b95e4575" sha512sum="bfb9e9b5bbfcf819f69682d9535a7664df6868da84dd4b8d6c7b24cd0275992ce0a8f4b86ff29448c984ecc5af3e14a1a04164244851173ca269730a8acd7614" version="5.1.0" release="2197.8">
            <name>amsd_5.1.0-2197.8-ubuntu26_amd64.deb</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd_5.1.0-2197.8-ubuntu26_amd64.deb</url>
            <file_list>
              <file>./etc/default/ahslog</file>
              <file>./etc/default/amsd</file>
              <file>./etc/default/amsd_rev</file>
              <file>./etc/default/cpqIde</file>
              <file>./etc/default/cpqScsi</file>
              <file>./etc/default/cpqiScsi</file>
              <file>./etc/default/mr_cpqScsi</file>
              <file>./etc/default/smad</file>
              <file>./etc/default/smad_rev</file>
              <file>./lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqiScsi</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/share/amsd/amsd.license</file>
              <file>./usr/share/doc/amsd/README.Debian</file>
              <file>./usr/share/doc/amsd/changelog.Debian.gz</file>
              <file>./usr/share/doc/amsd/copyright</file>
              <file>./usr/share/man/man1/ahslog.1m.gz</file>
              <file>./usr/share/man/man1/smad.1m.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="15698eb1529646ec8ffe029388a40fea">
      <product_version>
        <id product="15698eb1529646ec8ffe029388a40fea" version="d65b82bad0b54ab6883005c835c70c3f" lucid_version="ice.sles16@2.6.6-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Intel iceドライバーfor SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">Intel ice Drivers for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel iceドライバーfor SUSE Linux Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ice Drivers for SUSE Linux Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="2.6.6-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="14"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 16で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 16.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ice-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1177405" date_modified="2026-09-02T08:36:20" md5sum="941c5044973e03ff633ff6355f702a5a" sha1sum="aa989eec35868c8fb5731ad8b95c0ae06f6f8a8e" sha256sum="dccf929098a79ea4612887b50a733506040ce855402e991b36ddcc4733617052" sha512sum="399802f90f06381c4d01e09a049cc1ae5c3dff0ab18f9c7f82022eb84ec962fe1ae1c5b6e3bbd4c332435babe0e3b7e98cc28e47a9e611fcfa9825437a7e2913" version="2.6.6_k6.12.0_160000.5" release="1.sles16sp0">
            <name>ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/ice.ko</file>
              <file>./usr/share/doc/packages/ice-kmp-default</file>
              <file>./usr/share/doc/packages/ice-kmp-default/COPYING</file>
              <file>./usr/share/doc/packages/ice-kmp-default/README</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/pci.ids.d/pci.ids.ice-kmp-2.6.6</file>
              <file>./usr/share/smartupdate/ice-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="23c569ea92fb47f091a7a0c891acff72">
      <product_version>
        <id product="23c569ea92fb47f091a7a0c891acff72" version="6d1c79437e2b47fc8dde5ee7a65c50ce" lucid_version="FWPKG-P25960-B21@22.49.1014(A)__fwpkg-generic_en"/>
        <different>new</different>
        <build number="4"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">NVIDIAファームウェアパッケージ (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE</name_xlate>
          <name_xlate lang="en">NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">NVIDIAファームウェアパッケージ (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE</alt_name_xlate>
          <alt_name_xlate lang="en">NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE</alt_name_xlate>
        </alt_name>
        <version value="22.49.1014" revision="A" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="24" hour="06" minute="17" second="41"/>
        <description>
          <description_xlate lang="ja"><![CDATA[NVIDIA HPE署名済みPLDMファームウェアパッケージfor Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE]]></description_xlate>
          <description_xlate lang="en"><![CDATA[NVIDIA HPE signed PLDM Firmware Package for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKGは、アダプターにフラッシュされたファームウェアバージョンが22.27.1016以降の場合にのみ機能し、iLO5ファームウェアバージョンは2.30以降である必要があります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKG will work only if the firmware version flashed on the adapter is 22.27.1016 or later and iLO5 firmware version must be 2.30 or higher.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px">ローカルホストOSの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px">リモートの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li style="margin-left: 80px;">
	<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li style="margin-left: 80px;">
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3. iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li style="margin-left: 80px;">
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li style="margin-left: 80px;">
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px">Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td>
			<td>22.49.1014</td>
			<td>MT_0000000437</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td>
			<td>22.49.1014</td>
			<td>MT_0000000437</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="6" minor="3" sr="OEM" name="Microsoft Windows Server 2012 R2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="6" minor="0" sr="OEM" name="Red Hat Enterprise Linux 6 Server (x86-64)"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="7" minor="0" sr="OEM" name="Red Hat Enterprise Linux 7 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="11" minor="0" sr="OEM" name="SUSE LINUX Enterprise Server 11 (AMD64/EM64T)"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="5" sr="OEM" name="VMware vSphere 6.5"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="7" sr="OEM" name="VMware vSphere 6.7"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="32000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="Mellanox_NIC_PLDM_MCX623106AS-CDAT" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7927114" date_modified="2026-08-27T12:05:20" md5sum="38705ca630db5ce80a0564c5a7efc2ee" sha1sum="8bb486d6897fe0310e159b78557738da5b13befa" sha256sum="6d003bd488b943a7ddda145f8067dca3bd7cd56575a1dad1e989343bc6110cb4" sha512sum="5fce88b57c19c2c3dc69e5ddd02baed7e2441666847063c93b4f306284b63afbc68e5e765d8cf51e664ff3b87898a5a055e3fee025de318da7a77f9b103f4e0c">
            <name>22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg</url>
            <file_list>
              <file>22_49_1014-MCX623106AS-CDA_Ax.pldm.signed</file>
              <file>22_49_1014-MCX623106AS-CDA_Ax.pldm.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>22_49_1014-MCX623106AS-CDA_Ax.pldm.signed</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-15b3-101d15b30042</Target>
              <Version>22.49.1014</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="07f4f7fab144440d98173f5d8b539813">
      <product_version>
        <id product="07f4f7fab144440d98173f5d8b539813" version="572a1594841e4b56a6c8d70ac55eaf68" lucid_version="nicfwpkg_intel_e835_cq2@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="5"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="07" day="01" hour="06" minute="29" second="59"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-CQDA2 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-CQDA2 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-CQDA2&nbsp;Ethernet 100Gb 2-port QSFP28 Adapter</td>
			<td>80018D04</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-CQDA2&nbsp;Ethernet 100Gb 2-port QSFP28 Adapter</td>
			<td>80018D04</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_CQ2_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_CQDA2_2p10_MCTP_80018D04.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794279" date_modified="2026-08-18T07:02:56" md5sum="24ebdd6d00d09effdbc0cf6bd2d81b5f" sha1sum="ab77c55b6e845ba8764aa39f1d9976c9501ae78c" sha256sum="542b03909fd5e4ebc26e2791c8e979c1fa76b96db8f12fa2f5da9c2ada1ad535" sha512sum="00b94cf5ab8fc58ac2dc324f53f56bdfd9379109b7512c2e754f5fa4a41ee48dea0d451aa446abf0aafbf7e22b803a8702d6cf9863d86303c648336eb8864e8d">
            <name>HPE_E835_CQDA2_2p10_MCTP_80018D04.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_CQDA2_2p10_MCTP_80018D04.fwpkg</url>
            <file_list>
              <file>HPE_E835_CQDA2_2p10_MCTP_80018D04.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-CQDA2 adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_CQDA2_2p10_MCTP_80018D04.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124980860005</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="fbe3ee360df245b18e582f4894c4ab1e">
      <product_version>
        <id product="fbe3ee360df245b18e582f4894c4ab1e" version="763c62076fe64fec9f3e5d02bd5d5339" lucid_version="mlnx_en_roce_mlx5.rhel9u8x86_64.rpm@26.04__pubsw-linux_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 8 (x86_64)</name_xlate>
          <name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 8 (x86_64)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 8 (x86_64)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 8 (x86_64)</alt_name_xlate>
        </alt_name>
        <version value="26.04" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="24" hour="07" minute="17" second="50"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 Lx and above adapters.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 Lx and above adapters.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>Install&nbsp;<strong>chkconfig&nbsp;</strong>from respective OS repository prior to install the RoCE pakage.</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>Install&nbsp;<strong>chkconfig&nbsp;</strong>from respective OS repository prior to install the RoCE pakage.</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26.04&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />
<br />
To install or upgrade the driver:<br />
If using kernel version 5.14.0-687.5.3.el9_8.x86_64&nbsp;or any future errata:<br />
<br />
<strong># rpm -Uvh mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26.04&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />
<br />
To install or upgrade the driver:<br />
If using kernel version 5.14.0-687.5.3.el9_8.x86_64&nbsp;or any future errata:<br />
<br />
<strong># rpm -Uvh mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p><strong>This driver package supports the following adapters:</strong><br />
&nbsp;</p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li>
		<li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li>
		<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li>
		<li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p><strong>This driver package supports the following adapters:</strong><br />
&nbsp;</p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li>
		<li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li>
		<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li>
		<li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0237</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0073</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0086</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0085</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0053</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C9</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0052</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0246</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0346</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0117</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0102</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0047</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0256</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0282</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AB</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0068</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0347</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0345</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0348</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0069</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0040</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="mlnx-ofa_kernel" guid="20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-mlnx-ofa_kernel" guid="20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2706106" date_modified="2026-09-02T17:45:10" md5sum="58e4a3f28db71ad60d8a6e65643646cb" sha1sum="e8ca88559175a57c3b89dc84357e58d5f349bc01" sha256sum="a1015142fd81ba2106cb0375004e172b87a40a585912c2c7d43193d63ebcdc51" sha512sum="6fd19e27f3ea0de57108589be7fe6c8d30ea9d593f56f4f7263444a568be86088b388c9b67e41d9d613cd753c77f20adedaa95924f95f176e7897ce3b7b8b48b" version="26.04" release="OFED.26.04.0.8.6.1.rhel9u8">
            <name>mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./bin/mlnx_conf_mgr.sh</file>
              <file>./bin/mlnx_interface_mgr.sh</file>
              <file>./etc/infiniband</file>
              <file>./etc/infiniband/info</file>
              <file>./etc/infiniband/mlx5.conf</file>
              <file>./etc/infiniband/openib.conf</file>
              <file>./etc/init.d/openibd</file>
              <file>./etc/libibverbs.d</file>
              <file>./etc/libibverbs.d/mlx5.driver</file>
              <file>./etc/libvma.conf</file>
              <file>./etc/mellanox/hugepages.d</file>
              <file>./etc/modprobe.d/ib_ipoib.conf</file>
              <file>./etc/modprobe.d/mlnx-bf.conf</file>
              <file>./etc/modprobe.d/mlnx.conf</file>
              <file>./etc/rdma</file>
              <file>./etc/rdma/mlx4.conf</file>
              <file>./etc/rdma/modules</file>
              <file>./etc/rdma/modules/rdma.conf</file>
              <file>./etc/systemd/system/mlnx_interface_mgr@.service</file>
              <file>./lib/udev/auxdev-sf-netdev-rename</file>
              <file>./lib/udev/mlnx_bf_udev</file>
              <file>./lib/udev/rules.d/83-mlnx-sf-name.rules</file>
              <file>./lib/udev/rules.d/90-ib.rules</file>
              <file>./lib/udev/sf-rep-netdev-rename</file>
              <file>./sbin/doca-hugepages</file>
              <file>./sbin/mlnx-sf</file>
              <file>./sbin/mlnx_bf_configure</file>
              <file>./sbin/sysctl_perf_tuning</file>
              <file>./usr/bin/ib_atomic_bw</file>
              <file>./usr/bin/ib_atomic_lat</file>
              <file>./usr/bin/ib_read_bw</file>
              <file>./usr/bin/ib_read_lat</file>
              <file>./usr/bin/ib_send_bw</file>
              <file>./usr/bin/ib_send_lat</file>
              <file>./usr/bin/ib_write_bw</file>
              <file>./usr/bin/ib_write_lat</file>
              <file>./usr/bin/mlnx_dump_parser</file>
              <file>./usr/bin/mlnx_perf</file>
              <file>./usr/bin/mlnx_qos</file>
              <file>./usr/bin/mlx_fs_dump</file>
              <file>./usr/bin/ofed_info</file>
              <file>./usr/bin/ofed_rpm_info</file>
              <file>./usr/bin/raw_ethernet_burst_lat</file>
              <file>./usr/bin/raw_ethernet_bw</file>
              <file>./usr/bin/raw_ethernet_fs_rate</file>
              <file>./usr/bin/raw_ethernet_lat</file>
              <file>./usr/bin/run_perftest_loopback</file>
              <file>./usr/bin/run_perftest_multi_devices</file>
              <file>./usr/bin/tc_wrap.py</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/06</file>
              <file>./usr/lib/.build-id/06/c91c827e1c797a4ecb27d3e6a56d84b74d22df</file>
              <file>./usr/lib/.build-id/10</file>
              <file>./usr/lib/.build-id/10/d947fac5ec503d927e58fdfa821a634829738e</file>
              <file>./usr/lib/.build-id/16</file>
              <file>./usr/lib/.build-id/16/bfa88252e0d166cd5142998f8e863fe0c8fff8</file>
              <file>./usr/lib/.build-id/1e</file>
              <file>./usr/lib/.build-id/1e/f05f986f49aa67602464f7e33bf768f1614fae</file>
              <file>./usr/lib/.build-id/3f</file>
              <file>./usr/lib/.build-id/3f/48767f2130a07febc84c74cb5fa7a9620e64de</file>
              <file>./usr/lib/.build-id/40</file>
              <file>./usr/lib/.build-id/40/a3981455e5891a562f0fd698351a0f02bba6ae</file>
              <file>./usr/lib/.build-id/4a</file>
              <file>./usr/lib/.build-id/4a/0e36cb854a52462d7e096baf4fd6efaa3af81f</file>
              <file>./usr/lib/.build-id/4f</file>
              <file>./usr/lib/.build-id/4f/528ea5eb8f7481b97d12c44e480dd4d3e36026</file>
              <file>./usr/lib/.build-id/60</file>
              <file>./usr/lib/.build-id/60/26c9c6dafc8ae663e32176881a01f7b2c950ee</file>
              <file>./usr/lib/.build-id/64</file>
              <file>./usr/lib/.build-id/64/22de79525b447ddb1448745f5d8635f9e32fcb</file>
              <file>./usr/lib/.build-id/69</file>
              <file>./usr/lib/.build-id/69/e6b7a70d8da5c1666fce5e0fc1e1e1a8659184</file>
              <file>./usr/lib/.build-id/87</file>
              <file>./usr/lib/.build-id/87/f7169e8759f0e55131800404777eff6aa87655</file>
              <file>./usr/lib/.build-id/88</file>
              <file>./usr/lib/.build-id/88/7f1fd08f5cf3bc68002b8e4d98041e537bd2d9</file>
              <file>./usr/lib/.build-id/8c</file>
              <file>./usr/lib/.build-id/8c/4d69ff3b5f35a79957a59da55975a9fb1f7eab</file>
              <file>./usr/lib/.build-id/91</file>
              <file>./usr/lib/.build-id/91/03097315ab544a74dd3027ff83d1ddf7d12640</file>
              <file>./usr/lib/.build-id/94</file>
              <file>./usr/lib/.build-id/94/8aad76812eeaf5cf8dfea3b66aaeec21c00b3c</file>
              <file>./usr/lib/.build-id/a3</file>
              <file>./usr/lib/.build-id/a3/aac8cc43a7b1ae248e693e47d5b17298f52127</file>
              <file>./usr/lib/.build-id/a7</file>
              <file>./usr/lib/.build-id/a7/b1abfeaa9011b0db9af18f2b3be92b6eecdc2f</file>
              <file>./usr/lib/.build-id/ad</file>
              <file>./usr/lib/.build-id/ad/c70fdf8790b5999a7b560aac69680db7ed2fe7</file>
              <file>./usr/lib/.build-id/c0</file>
              <file>./usr/lib/.build-id/c0/ff1f3f8335059454c4aabac82dc7040fa04881</file>
              <file>./usr/lib/.build-id/cd</file>
              <file>./usr/lib/.build-id/cd/0c01094285274e728b2160a1cce6afb805bc12</file>
              <file>./usr/lib/.build-id/df</file>
              <file>./usr/lib/.build-id/df/8140d774c81739357a45be24834702d609e668</file>
              <file>./usr/lib/.build-id/e2</file>
              <file>./usr/lib/.build-id/e2/4e91897066b8f592a295c0a7fba68dfec65156</file>
              <file>./usr/lib/.build-id/f5</file>
              <file>./usr/lib/.build-id/f5/92e5dfc914e9e6ba53a93380a805d39f77e168</file>
              <file>./usr/lib/dracut</file>
              <file>./usr/lib/dracut/modules.d</file>
              <file>./usr/lib/dracut/modules.d/50rdma</file>
              <file>./usr/lib/modprobe.d</file>
              <file>./usr/lib/modprobe.d/libmlx4.conf</file>
              <file>./usr/lib/systemd/system/openibd.service</file>
              <file>./usr/lib/systemd/system/rdma-ndd.service</file>
              <file>./usr/lib/systemd/system/vma.service</file>
              <file>./usr/lib/udev/rdma_rename</file>
              <file>./usr/lib/udev/rules.d</file>
              <file>./usr/lib/udev/rules.d/60-rdma-ndd.rules</file>
              <file>./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules</file>
              <file>./usr/lib/udev/rules.d/75-rdma-description.rules</file>
              <file>./usr/lib/udev/rules.d/90-rdma-umad.rules</file>
              <file>./usr/lib64/libefa.so.1</file>
              <file>./usr/lib64/libefa.so.1.4.63.0</file>
              <file>./usr/lib64/libibumad.so.3</file>
              <file>./usr/lib64/libibumad.so.3.4.63.0</file>
              <file>./usr/lib64/libibverbs</file>
              <file>./usr/lib64/libibverbs.so.1</file>
              <file>./usr/lib64/libibverbs.so.1.16.63.0</file>
              <file>./usr/lib64/libibverbs/libmlx5-rdmav59.so</file>
              <file>./usr/lib64/libmlx4.so.1</file>
              <file>./usr/lib64/libmlx4.so.1.0.63.0</file>
              <file>./usr/lib64/libmlx5.so.1</file>
              <file>./usr/lib64/libmlx5.so.1.27.63.0</file>
              <file>./usr/lib64/libperftest_kernels.so</file>
              <file>./usr/lib64/librdmacm.so.1</file>
              <file>./usr/lib64/librdmacm.so.1.4.63.0</file>
              <file>./usr/lib64/libvma.so</file>
              <file>./usr/lib64/libvma.so.9</file>
              <file>./usr/lib64/libvma.so.9.8.84</file>
              <file>./usr/lib64/rsocket</file>
              <file>./usr/lib64/rsocket/librspreload.so</file>
              <file>./usr/lib64/rsocket/librspreload.so.1</file>
              <file>./usr/lib64/rsocket/librspreload.so.1.0.0</file>
              <file>./usr/libexec/mlx4-setup.sh</file>
              <file>./usr/sbin/cma_roce_mode</file>
              <file>./usr/sbin/cma_roce_tos</file>
              <file>./usr/sbin/common_irq_affinity.sh</file>
              <file>./usr/sbin/compat_gid_gen</file>
              <file>./usr/sbin/ib2ib_setup</file>
              <file>./usr/sbin/ibdev2netdev</file>
              <file>./usr/sbin/mlnx_affinity</file>
              <file>./usr/sbin/mlnx_tune</file>
              <file>./usr/sbin/mlnxofedctl</file>
              <file>./usr/sbin/ofed_uninstall.sh</file>
              <file>./usr/sbin/rdma-ndd</file>
              <file>./usr/sbin/rdma_topo</file>
              <file>./usr/sbin/set_irq_affinity.sh</file>
              <file>./usr/sbin/set_irq_affinity_bynode.sh</file>
              <file>./usr/sbin/set_irq_affinity_cpulist.sh</file>
              <file>./usr/sbin/setup_mr_cache.sh</file>
              <file>./usr/sbin/show_counters</file>
              <file>./usr/sbin/show_gids</file>
              <file>./usr/sbin/show_irq_affinity.sh</file>
              <file>./usr/sbin/show_irq_affinity_hints.sh</file>
              <file>./usr/sbin/sysinfo-snapshot.py</file>
              <file>./usr/sbin/vendor_post_uninstall.sh</file>
              <file>./usr/sbin/vendor_pre_uninstall.sh</file>
              <file>./usr/sbin/vmad</file>
              <file>./usr/share/doc/libibverbs</file>
              <file>./usr/share/doc/libibverbs/libibverbs.md</file>
              <file>./usr/share/doc/librdmacm</file>
              <file>./usr/share/doc/librdmacm/librdmacm.md</file>
              <file>./usr/share/doc/libvma</file>
              <file>./usr/share/doc/libvma/CHANGES</file>
              <file>./usr/share/doc/libvma/README</file>
              <file>./usr/share/doc/mlnx-ofa_kernel</file>
              <file>./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules</file>
              <file>./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh</file>
              <file>./usr/share/doc/mlnx-tools</file>
              <file>./usr/share/doc/mlnx-tools/ib2ib_setup.txt</file>
              <file>./usr/share/doc/perftest</file>
              <file>./usr/share/doc/perftest/COPYING</file>
              <file>./usr/share/doc/perftest/README</file>
              <file>./usr/share/doc/perftest/runme</file>
              <file>./usr/share/doc/rdma-core</file>
              <file>./usr/share/doc/rdma-core/70-persistent-ipoib.rules</file>
              <file>./usr/share/doc/rdma-core/README.md</file>
              <file>./usr/share/doc/rdma-core/tag_matching.md</file>
              <file>./usr/share/doc/rdma-core/udev.md</file>
              <file>./usr/share/licenses/libvma</file>
              <file>./usr/share/licenses/libvma/LICENSE</file>
              <file>./usr/share/licenses/mlnx-tools</file>
              <file>./usr/share/licenses/mlnx-tools/LICENSE</file>
              <file>./usr/share/licenses/rdma-core</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_FB</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_MIT</file>
              <file>./usr/share/licenses/rdma-core/COPYING.GPL2</file>
              <file>./usr/share/licenses/rdma-core/COPYING.md</file>
              <file>./usr/share/man/man1/ib_atomic_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_atomic_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_read_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_read_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_send_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_send_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_write_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_write_lat.1.gz</file>
              <file>./usr/share/man/man1/perftest.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_burst_lat.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_bw.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_fs_rate.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_lat.1.gz</file>
              <file>./usr/share/man/man7/rsocket.7.gz</file>
              <file>./usr/share/man/man7/vma.7.gz</file>
              <file>./usr/share/man/man8/ib2ib_setup.8.gz</file>
              <file>./usr/share/man/man8/mlnxofedctl.8.gz</file>
              <file>./usr/share/man/man8/rdma-ndd.8.gz</file>
              <file>./usr/share/man/man8/vmad.8.gz</file>
              <file>./usr/share/mlnx-tools/python/dcbnetlink.py</file>
              <file>./usr/share/mlnx-tools/python/netlink.py</file>
              <file>./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh</file>
              <file>./usr/share/mlnx_ofed/mlnx_drv_ctl</file>
              <file>./usr/share/mlnx_ofed/mod_load_funcs</file>
              <file>./usr/share/smartupdate/mlnx-ofa_kernel/component.xml</file>
            </file_list>
          </file>
          <file size="2MB" bytes="2780066" date_modified="2026-09-02T17:40:54" md5sum="83dd4ca7c1846569dcc8104a36cf88dc" sha1sum="1cbb681c14dfad107362c2638e195ecd906259a5" sha256sum="f4866970c64ec0fb63952adbe851982b93db9d9e83ac723bbe4d9b777f8655f8" sha512sum="f71c71a7135b14dbc32e30d71082bfaf38138570ca0b8783be2d06bd6f439e0b2b8e541622ad74e8629a26758dc572ce888dc5898402cd2cd899a985f45f162f" version="26.04" release="OFED.26.04.0.8.6.1.1.rhel9u8">
            <name>kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/compat</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs/cifs</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/08</file>
              <file>./usr/lib/.build-id/08/704e7abc42177e2128d40dc318b88925f98a5b</file>
              <file>./usr/lib/.build-id/08/dd9a21622b0d24503f8e5d58b35229ed243ac5</file>
              <file>./usr/lib/.build-id/11</file>
              <file>./usr/lib/.build-id/11/2ed8a9e4ea240ea679404b86dfb04f9a015c56</file>
              <file>./usr/lib/.build-id/11/fd74195d6842dd2df66899133cc608a34847a3</file>
              <file>./usr/lib/.build-id/18</file>
              <file>./usr/lib/.build-id/18/0f8330d95e3b996c48aa56aee926936cd8600c</file>
              <file>./usr/lib/.build-id/1b</file>
              <file>./usr/lib/.build-id/1b/7467b922167fd19742666d2ea73e27cac32b50</file>
              <file>./usr/lib/.build-id/24</file>
              <file>./usr/lib/.build-id/24/ebc0db87f796dbae31c7d2b4331d6419cd98fc</file>
              <file>./usr/lib/.build-id/27</file>
              <file>./usr/lib/.build-id/27/d9bad8ce91cdfa2f95bc61b69bcba4200cbfae</file>
              <file>./usr/lib/.build-id/2a</file>
              <file>./usr/lib/.build-id/2a/b1f426e239840c6547dc5f79526cbf4f2ebaec</file>
              <file>./usr/lib/.build-id/2b</file>
              <file>./usr/lib/.build-id/2b/58e4aa7b640e1ae26753eb13d59a8781c80dcf</file>
              <file>./usr/lib/.build-id/2c</file>
              <file>./usr/lib/.build-id/2c/d6961b34ffdedfd2a82fa09473fa653930d282</file>
              <file>./usr/lib/.build-id/31</file>
              <file>./usr/lib/.build-id/31/0d36f4c9f88fdaacdb5358480974075e6e0006</file>
              <file>./usr/lib/.build-id/35</file>
              <file>./usr/lib/.build-id/35/657bd534ca0482a8565ec411c7b77af01d9a31</file>
              <file>./usr/lib/.build-id/3f</file>
              <file>./usr/lib/.build-id/3f/c71248c8147c91d07362df9fdb6efe6e8448c7</file>
              <file>./usr/lib/.build-id/40</file>
              <file>./usr/lib/.build-id/40/79a2f16e5a4112c87168f2c50860dea894fef6</file>
              <file>./usr/lib/.build-id/4e</file>
              <file>./usr/lib/.build-id/4e/0061b424d0bddd091b89b586fb7de125434263</file>
              <file>./usr/lib/.build-id/54</file>
              <file>./usr/lib/.build-id/54/dd5db0fb4052a3e14b0335c66e1ddb7ed11bf3</file>
              <file>./usr/lib/.build-id/55</file>
              <file>./usr/lib/.build-id/55/33b3011d9213b54e2809111b19a05b52a45988</file>
              <file>./usr/lib/.build-id/59</file>
              <file>./usr/lib/.build-id/59/bbef9ef8ca2184f1bec652844feb33f55d57cd</file>
              <file>./usr/lib/.build-id/5c</file>
              <file>./usr/lib/.build-id/5c/04edf9e06aa03794a53d91a24b8e434f4f06c9</file>
              <file>./usr/lib/.build-id/5f</file>
              <file>./usr/lib/.build-id/5f/ef79c08865897850f9f47f1f0503920c46b790</file>
              <file>./usr/lib/.build-id/60</file>
              <file>./usr/lib/.build-id/60/9a5534a3cf0abe9e29d4d8f7a4acc6546918ad</file>
              <file>./usr/lib/.build-id/64</file>
              <file>./usr/lib/.build-id/64/2fdda65b4cee529fb9c6e1b2b60548b69205aa</file>
              <file>./usr/lib/.build-id/67</file>
              <file>./usr/lib/.build-id/67/5906bbf1f17ab4e67102956cfbc531fd07ad98</file>
              <file>./usr/lib/.build-id/69</file>
              <file>./usr/lib/.build-id/69/4df5828387e42ffe71477fbd9f28fc5f4faa1b</file>
              <file>./usr/lib/.build-id/6e</file>
              <file>./usr/lib/.build-id/6e/134c5ec72437de490b8415db3a9c24d1c172cc</file>
              <file>./usr/lib/.build-id/88</file>
              <file>./usr/lib/.build-id/88/fb6c119c9034313c984ab88116493149b68a18</file>
              <file>./usr/lib/.build-id/8e</file>
              <file>./usr/lib/.build-id/8e/83d3263da0b6445fd3d31e7826fd729778d04b</file>
              <file>./usr/lib/.build-id/9c</file>
              <file>./usr/lib/.build-id/9c/f23d4d4ddd07d475bed11352eda3251433de84</file>
              <file>./usr/lib/.build-id/a1</file>
              <file>./usr/lib/.build-id/a1/a1a140e5b0b6c5b71862490069943e2776cdd2</file>
              <file>./usr/lib/.build-id/a4</file>
              <file>./usr/lib/.build-id/a4/e95ccd26a792b1a7565af25a71655fad3ec8fd</file>
              <file>./usr/lib/.build-id/a8</file>
              <file>./usr/lib/.build-id/a8/4b7a1a0c50dd4c0580a11c12902d1234fbbd3c</file>
              <file>./usr/lib/.build-id/a8/6df975ea6a35a50eb32e4597c41c2b92fb297c</file>
              <file>./usr/lib/.build-id/aa</file>
              <file>./usr/lib/.build-id/aa/04812e399cbf42aea028ca47dc829159ec0282</file>
              <file>./usr/lib/.build-id/b4</file>
              <file>./usr/lib/.build-id/b4/ab62442cf7e5a354464caf9a5d103fc5ec80e6</file>
              <file>./usr/lib/.build-id/bc</file>
              <file>./usr/lib/.build-id/bc/a460e026689be91cf56baa1032d0f0710d429b</file>
              <file>./usr/lib/.build-id/ce</file>
              <file>./usr/lib/.build-id/ce/e7cb3e5d8856b462f587d6b30b92478233640c</file>
              <file>./usr/lib/.build-id/d7</file>
              <file>./usr/lib/.build-id/d7/a8999f885763bdf22eb83250e2b8914f69a0ff</file>
              <file>./usr/lib/.build-id/df</file>
              <file>./usr/lib/.build-id/df/0eba2667ad94e10eae316fde83e13dd080c466</file>
              <file>./usr/lib/.build-id/f1</file>
              <file>./usr/lib/.build-id/f1/414cef0eff85233c68c01fbe94315a191ea9c2</file>
              <file>./usr/lib/.build-id/f3</file>
              <file>./usr/lib/.build-id/f3/429b39317410fa16b9d6807774c1443677eee5</file>
              <file>./usr/lib/.build-id/fa</file>
              <file>./usr/lib/.build-id/fa/52f18148e62297e981f1f128ae33c0c6e09ee3</file>
              <file>./usr/lib/.build-id/fb</file>
              <file>./usr/lib/.build-id/fb/44246158db13feeec8773362228955f1d8b02a</file>
              <file>./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="a401f075d5674043a59187ed0394a10a">
      <product_version>
        <id product="a401f075d5674043a59187ed0394a10a" version="47ff3079759a4e5484e34e24aeb39553" lucid_version="ilo8.sanjac.asr.win2025.x64@4.8.1.0__sc-windows_en"/>
        <different>new</different>
        <build number="4"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">iLO 8 Automatic Server Recovery Driver for Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">iLO 8 Automatic Server Recovery Driver for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">iLO 8 Automatic Server Recovery Driver</alt_name_xlate>
          <alt_name_xlate lang="en">iLO 8 Automatic Server Recovery Driver</alt_name_xlate>
        </alt_name>
        <version value="4.8.1.0" revision="" type_of_change="0"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300032">
          <category_xlate lang="ja">ドライバ - システム マネジメント</category_xlate>
          <category_xlate lang="en">Driver - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[The iLO 8 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[The iLO 8 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>

<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>

<p>Click the &quot;Install&quot; button to perform the driver installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>

<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>

<p>Click the &quot;Install&quot; button to perform the driver installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Optional"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <supported_platforms>
            <supported_platform rom="A72"/>
          </supported_platforms>
          <required_diskspace size_kb="2000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Environment Dependent">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot may be required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="sanjacasr.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecc4248571">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="sanjacasr.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecc4248571">
              <sw_key_expectedpath>%systemroot%\system32\DriverStore\FileRepository\sanjacasr.inf_amd64_e44b63bb818e0dbe</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071678.exe</filename>
        <component_config/>
        <files>
          <file size="576KB" bytes="590024" date_modified="2026-09-14T03:13:13" md5sum="82be2587268d5e4c4ae5f4a9419ff624" sha1sum="8b9062ab8ecae74af3381e48b5babee16cea18bd" sha256sum="d0a682d2762cd5e21fdabacaad28d9da3ef1b38cb3d6a337a879f079b3f3f63c" sha512sum="4e21b0efaac5b14f16fb16f2be1c13c72beb8b7b7de60972cdfc39b0e4acc196689c1c8eda91c03ddc96d670a542e3eb26752acca3f552cdaaa80116ac735792">
            <name>cp071678.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071678.exe</url>
            <file_list>
              <file>cp071678.xml</file>
              <file>cpqsetup.exe</file>
              <file>generic.dll</file>
              <file>install.xml</file>
              <file>sanjacasr.cat</file>
              <file>sanjacasr.inf</file>
              <file>sanjacasr.sys</file>
              <file>scripts/</file>
              <file>scripts/Get-AsrSettings.ps1</file>
              <file>scripts/Set-AsrPreTimeoutNMI.ps1</file>
              <file>scripts/Set-AsrTimeout.ps1</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="c549eb5726da4e0ab54cbcdd6abecebd">
      <product_version>
        <id product="c549eb5726da4e0ab54cbcdd6abecebd" version="3bbecc404a204fa0b0a460d366e43e4e" lucid_version="bnxt.rhel9@1.10.3-238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="4"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9</alt_name_xlate>
        </alt_name>
        <version value="1.10.3-238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 9.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-bnxt_en" guid="20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-bnxt_en" guid="20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1437506" date_modified="2026-09-03T02:52:30" md5sum="183d61bd31317343d017cc20fbc0c80c" sha1sum="e477525f87f850f9d7408f5d65b83ed0c8ea63b8" sha256sum="29aa84069e354cf138498c1e84ef0c7d94d4e0f542538f4a14c9515c17163a2c" sha512sum="e64a2b56ad02cd3d016c90eb290c744f1c801f175ca37cdede44334f85d2cac958773897ab3e3939499ebf5ba87584a5b3dc764b8bb5a6a74119e3e096a4bc0a" version="1.10.3" release="238.1.165.0.rhel9u8">
            <name>kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/bnxt_en.conf</file>
              <file>./etc/depmod.d/bnxt_re.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/bnxt_en.ko</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/kmod-bnxt_en/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1460769" date_modified="2026-09-03T02:48:12" md5sum="f0ba20e242c5903d3935686d81641820" sha1sum="5cc0d07ce596e33eaaa00dea270face441dfff91" sha256sum="59939cb0c8d912b9c7cf0b9fadfd99e2eca35c89986a76d15a0ba90590705287" sha512sum="cc85a2aca65b3b04ad4d57912badbc8d7f98dbad149a77f13498e819e220f78a2c49ef43106470c300711516cfdca83a5c31e03f0c7a30fd777b2edb808ee2ea" version="1.10.3" release="238.1.165.0.rhel9u7">
            <name>kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/bnxt_en.conf</file>
              <file>./etc/depmod.d/bnxt_re.conf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/bnxt_en.ko</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/kmod-bnxt_en/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="fefae5f129c9429dbe5f506829e99ac7">
      <product_version>
        <id product="fefae5f129c9429dbe5f506829e99ac7" version="3026c56f695140fb80f8650cf8af6abb" lucid_version="ixgbevf.sles16@5.3.36-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 16</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 16</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 16</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 16</alt_name_xlate>
        </alt_name>
        <version value="5.3.36-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products/>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="55"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 16で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 16.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ixgbevf-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec0183d0f4">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="106KB" bytes="108648" date_modified="2026-09-02T10:03:22" md5sum="ec3ed2d54daed788133b096470b320cd" sha1sum="dd6d90e60552b3e68fece71b998f8158645e370e" sha256sum="f58d0354b947ba767160ea680f0670d6a46eadd52f563531c84179f8138556b8" sha512sum="c7ad8b3b42d995b993d63753b8745587389f69e5e9bd97034fca2e459abc32abc279cfd5d552821cc4f2e6f39ff189cf84131a0e3469537d648988878d9751fa" version="5.3.36_k6.12.0_160000.5" release="1.sles16sp0">
            <name>ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbevf.ko</file>
              <file>./usr/share/doc/packages/ixgbevf-kmp-default</file>
              <file>./usr/share/doc/packages/ixgbevf-kmp-default/COPYING</file>
              <file>./usr/share/doc/packages/ixgbevf-kmp-default/README</file>
              <file>./usr/share/man/man7/ixgbevf.7.gz</file>
              <file>./usr/share/pci.ids.d/pci.ids.ixgbevf-kmp-5.3.36</file>
              <file>./usr/share/smartupdate/ixgbevf-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="37b6e65ded4e403daf3c081820ceaac6">
      <product_version>
        <id product="37b6e65ded4e403daf3c081820ceaac6" version="289744ce37864d7caeb2850fcac59502" lucid_version="nicfwpkg_intel_e610_it4ocp@1.60(B)__fwpkg-generic_en"/>
        <different>new</different>
        <build number="8"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intelファームウェアパッケージfor E610-IT4 Ethernet 1Gb 4ポートBASE-T OCP3アダプター</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E610-IT4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intelファームウェアパッケージfor E610-IT4 Ethernet 1Gb 4ポートBASE-T OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E610-IT4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="1.60" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="56"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Intel E610-IT4 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E610-IT4 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href="https://support.hpe.com/">https://support.hpe.com</a>を参照してください。</p>

<p>ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p>リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li>
	<p><a href="https://support.hpe.com/">USB Key Creator Utility</a> (https://support.hpe.comで検索してダウンロード) を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p>
	</li>
	<li>
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3. iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
	<li>
	<p>HPE Intel E610ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E610-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E610-IT4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE</td>
			<td>8000F176</td>
			<td>1.3998.0</td>
			<td>1.60</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 1.60</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>

<p>This product doesn&#39;t support changing Link Speed in NIC HII menu.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E610-IT4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE</td>
			<td>8000F176</td>
			<td>1.3998.0</td>
			<td>1.60</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 1.60</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>

<p>This product doesn&#39;t support changing Link Speed in NIC HII menu.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E610_IT4OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E610_IT4_OCP_1p60_8000F176.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794273" date_modified="2026-08-18T06:23:15" md5sum="b3513bee42b990dfa01c9749acb8e066" sha1sum="3e69135ec7094757edcda7d8bbfddbf0b3b3fdba" sha256sum="2753fd71fac1dd25a572d5d2945331b5a318d66b773c2eeac8ca6f1e7871357c" sha512sum="6bc58aabff67ee6578940346d88547bc1c229a51c31ee6c1c726a880e0e9d1484c84d023b08d3dcf66111a2329634dcae08da5118690963ada045a21fb5e25e7">
            <name>HPE_E610_IT4_OCP_1p60_8000F176.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E610_IT4_OCP_1p60_8000F176.fwpkg</url>
            <file_list>
              <file>HPE_E610_IT4_OCP_1p60_8000F176.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E610-IT4 OCP3 adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E610_IT4_OCP_1p60_8000F176.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-57b180860003</Target>
              <Version>1.60</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="710acbec2a70445381651a2e1f3c55ab">
      <product_version>
        <id product="710acbec2a70445381651a2e1f3c55ab" version="afe47bd448d349a6b34cfba8f1385793" lucid_version="mlnx_en_roce_mlx5.sles15sp7.x86_64.rpm@26.04(A)__pubsw-linux_en"/>
        <different>new</different>
        <build number="2"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Mellanox RoCEドライバー[ConnectX-4 Lxおよびそれ以降] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)</name_xlate>
          <name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Mellanox RoCEドライバー[ConnectX-4 Lxおよびそれ以降] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)</alt_name_xlate>
        </alt_name>
        <version value="26.04" revision="A" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="06" minute="26" second="45"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このRPMには、HPEによるテストと承認済みのLinuxベースMellanox RoCE ConnectX-4 Lxおよびそれ以降のアダプターが含まれます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 Lx and above adapters.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ドライバーコンポーネントをインストールする前に、以下のパッケージをそれぞれのOSのディストリビューションからインストールする必要があります。</p>

<ul>
	<li>Pythonバージョン2.7</li>
	<li>pciutilsとlibpci3</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>Following packages must be installed from the respective OS distributions prior to installing the driver component:</p>

<ul>
	<li>Python version 2.7</li>
	<li>pciutils along with libpci3</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26.04&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br />
<br />
To install or upgrade the driver:<br />
If using 6.4.0-150700.51-default kernel or any future errata:<br />
<br />
<strong># rpm -Uvh mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26.04&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br />
<br />
To install or upgrade the driver:<br />
If using 6.4.0-150700.51-default kernel or any future errata:<br />
<br />
<strong># rpm -Uvh mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p><strong>このドライバーパッケージは、以下のアダプターをサポートします：</strong></p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2ポート640SFP28アダプター(817753-B21)</li>
		<li>HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター(817749-B21) </li>
		<li>HPE Ethernet 10Gb 2ポート548SFP+アダプター(P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCHTアダプター(P21930-B21) </li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3アダプター(P11341-B21) <br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター(P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター(P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1ポート842QSFP28アダプター (874253-B21) </li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2ポート841QSFP28アダプター(872726-B21 / 872726-H21)<br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1ポート940QSFP56 x16アダプター(P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポート940QSFP56 x16アダプター(P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポート940QSFP56 x16アダプター(P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-ECATアダプター(P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 MCX653105A-HDATアダプター(P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-ECATアダプター(P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 OCP3 MCX653436A-HDAIアダプター(P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 OCP3 MCX653435A-HDAIアダプター(P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 PCIe4 x16 MCX653106A-HDATアダプター(P31324-B21 / P31324-H21)<br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1ポートQSFP56アダプターfor HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE (P25960-B21)<br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE (P42041-B21)<br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2ポートQSFP112 PCIe5 x16 MCX755106AC-HEATアダプター (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-NEATアダプター(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1ポートQSFP112 PCIe5 x16 MCX715105AS-WEATアダプター (S5R60A)</li>
		<li>HPE InfiniBand NDR 1ポートOSFP PCIe5 x16 MCX75310AAS-NEATアダプター (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター (P45642-B21)<br />
		 </li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2ポート QSFP112 PCIe6 x16 HHHL CX8 暗号化アダプター (P79114-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1ポート OSFP PCIe6 x16 HHHL CX8 暗号化アダプター (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p><strong>This driver package supports the following adapters:</strong></p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li>
		<li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li>
		<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li>
		<li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0237</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0073</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0086</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0085</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0053</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C9</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0052</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0246</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0346</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0117</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0102</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0047</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0256</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0282</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AB</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0068</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0347</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0345</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0348</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0069</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0040</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="mlnx-ofa_kernel-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="mlnx-ofa_kernel" guid="20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2712395" date_modified="2026-09-03T10:43:34" md5sum="13932b1892ae87144a9339863d2ac0a8" sha1sum="4cb77d06a6e19daf624910341cea6204200ac0ae" sha256sum="dbbc39f3c72d8ef082ce4720896aeeb1cb3064bf6048a27f6edd8ea8395ef2f7" sha512sum="adbbdbd5b633189f2e0a617df68c394da29195cf18ac35dda9dab0e77d05dd68ecc79cc502ce6b57cf793b6b641a663d3a85b806db09f2696ab9b79761466d2e" version="26.04_k6.4.0_150700.51" release="OFED.26.04.0.8.6.1.1.sles15sp7">
            <name>mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/compat</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/compat/mlx_compat.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/block</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-client.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-server.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/fwctl.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_cm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_core.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_ucm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_umad.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_uverbs.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/iw_cm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_cm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_ucm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa/efa.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma/erdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma/irdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana/mana_ib.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr/qedr.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib/ib_qib.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw/siw.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host/nvme-rdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target/nvmet-rdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/9p</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/9p/9pnet_rdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm/mlxdevm.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/rds</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/rds/rds_rdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/smc</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc_diag.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/svcrdma.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko</file>
              <file>./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="9MB" bytes="10236531" date_modified="2026-09-03T10:38:24" md5sum="a7420b7ac114fe37c0c92b99083c0d91" sha1sum="cba73ba1dec86b41984dd97bc3b4a9dac015aac7" sha256sum="74430350cd0ba2f0a1b6311267268a04e7598b6cf061b0fb8f40f65498e6c187" sha512sum="d7bb9eaa6582e01046d31ea9ec9bd2c8c2990d85414df655b7294f98f6809f9ce6b4188e1aec08ea818db89d09bd4c43a6e0baeb08708ebe878c76d3ffc78063" version="26.04" release="OFED.26.04.0.8.6.1.sles15sp7">
            <name>mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./bin/mlnx_conf_mgr.sh</file>
              <file>./bin/mlnx_interface_mgr.sh</file>
              <file>./etc/infiniband</file>
              <file>./etc/infiniband/info</file>
              <file>./etc/infiniband/mlx5.conf</file>
              <file>./etc/infiniband/openib.conf</file>
              <file>./etc/init.d/openibd</file>
              <file>./etc/libibverbs.d</file>
              <file>./etc/libibverbs.d/mlx5.driver</file>
              <file>./etc/libvma.conf</file>
              <file>./etc/mellanox/hugepages.d</file>
              <file>./etc/modprobe.d/ib_ipoib.conf</file>
              <file>./etc/modprobe.d/mlnx-bf.conf</file>
              <file>./etc/modprobe.d/mlnx.conf</file>
              <file>./etc/rdma</file>
              <file>./etc/rdma/mlx4.conf</file>
              <file>./etc/rdma/modules</file>
              <file>./etc/rdma/modules/rdma.conf</file>
              <file>./etc/systemd/system/mlnx_interface_mgr@.service</file>
              <file>./lib/udev/auxdev-sf-netdev-rename</file>
              <file>./lib/udev/mlnx_bf_udev</file>
              <file>./lib/udev/rules.d/83-mlnx-sf-name.rules</file>
              <file>./lib/udev/rules.d/90-ib.rules</file>
              <file>./lib/udev/sf-rep-netdev-rename</file>
              <file>./sbin/doca-hugepages</file>
              <file>./sbin/mlnx-sf</file>
              <file>./sbin/mlnx_bf_configure</file>
              <file>./sbin/sysctl_perf_tuning</file>
              <file>./usr/bin/ib_atomic_bw</file>
              <file>./usr/bin/ib_atomic_lat</file>
              <file>./usr/bin/ib_read_bw</file>
              <file>./usr/bin/ib_read_lat</file>
              <file>./usr/bin/ib_send_bw</file>
              <file>./usr/bin/ib_send_lat</file>
              <file>./usr/bin/ib_write_bw</file>
              <file>./usr/bin/ib_write_lat</file>
              <file>./usr/bin/mlnx_dump_parser</file>
              <file>./usr/bin/mlnx_perf</file>
              <file>./usr/bin/mlnx_qos</file>
              <file>./usr/bin/mlx_fs_dump</file>
              <file>./usr/bin/ofed_info</file>
              <file>./usr/bin/ofed_rpm_info</file>
              <file>./usr/bin/raw_ethernet_burst_lat</file>
              <file>./usr/bin/raw_ethernet_bw</file>
              <file>./usr/bin/raw_ethernet_fs_rate</file>
              <file>./usr/bin/raw_ethernet_lat</file>
              <file>./usr/bin/run_perftest_loopback</file>
              <file>./usr/bin/run_perftest_multi_devices</file>
              <file>./usr/bin/tc_wrap.py</file>
              <file>./usr/lib/dracut</file>
              <file>./usr/lib/dracut/modules.d</file>
              <file>./usr/lib/dracut/modules.d/50rdma</file>
              <file>./usr/lib/mlx4-setup.sh</file>
              <file>./usr/lib/modprobe.d</file>
              <file>./usr/lib/modprobe.d/libmlx4.conf</file>
              <file>./usr/lib/systemd/system/openibd.service</file>
              <file>./usr/lib/systemd/system/rdma-ndd.service</file>
              <file>./usr/lib/systemd/system/vma.service</file>
              <file>./usr/lib/udev/rdma_rename</file>
              <file>./usr/lib/udev/rules.d</file>
              <file>./usr/lib/udev/rules.d/60-rdma-ndd.rules</file>
              <file>./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules</file>
              <file>./usr/lib/udev/rules.d/75-rdma-description.rules</file>
              <file>./usr/lib/udev/rules.d/90-rdma-umad.rules</file>
              <file>./usr/lib64/libefa.so.1</file>
              <file>./usr/lib64/libefa.so.1.4.63.0</file>
              <file>./usr/lib64/libibumad.so.3</file>
              <file>./usr/lib64/libibumad.so.3.4.63.0</file>
              <file>./usr/lib64/libibverbs</file>
              <file>./usr/lib64/libibverbs.so.1</file>
              <file>./usr/lib64/libibverbs.so.1.16.63.0</file>
              <file>./usr/lib64/libibverbs/libmlx5-rdmav59.so</file>
              <file>./usr/lib64/libmlx4.so.1</file>
              <file>./usr/lib64/libmlx4.so.1.0.63.0</file>
              <file>./usr/lib64/libmlx5.so.1</file>
              <file>./usr/lib64/libmlx5.so.1.27.63.0</file>
              <file>./usr/lib64/libperftest_kernels.so</file>
              <file>./usr/lib64/librdmacm.so.1</file>
              <file>./usr/lib64/librdmacm.so.1.4.63.0</file>
              <file>./usr/lib64/libvma.so</file>
              <file>./usr/lib64/libvma.so.9</file>
              <file>./usr/lib64/libvma.so.9.8.84</file>
              <file>./usr/lib64/rsocket</file>
              <file>./usr/lib64/rsocket/librspreload.so</file>
              <file>./usr/lib64/rsocket/librspreload.so.1</file>
              <file>./usr/lib64/rsocket/librspreload.so.1.0.0</file>
              <file>./usr/sbin/cma_roce_mode</file>
              <file>./usr/sbin/cma_roce_tos</file>
              <file>./usr/sbin/common_irq_affinity.sh</file>
              <file>./usr/sbin/compat_gid_gen</file>
              <file>./usr/sbin/ib2ib_setup</file>
              <file>./usr/sbin/ibdev2netdev</file>
              <file>./usr/sbin/mlnx_affinity</file>
              <file>./usr/sbin/mlnx_tune</file>
              <file>./usr/sbin/mlnxofedctl</file>
              <file>./usr/sbin/ofed_uninstall.sh</file>
              <file>./usr/sbin/rdma-ndd</file>
              <file>./usr/sbin/rdma_topo</file>
              <file>./usr/sbin/set_irq_affinity.sh</file>
              <file>./usr/sbin/set_irq_affinity_bynode.sh</file>
              <file>./usr/sbin/set_irq_affinity_cpulist.sh</file>
              <file>./usr/sbin/setup_mr_cache.sh</file>
              <file>./usr/sbin/show_counters</file>
              <file>./usr/sbin/show_gids</file>
              <file>./usr/sbin/show_irq_affinity.sh</file>
              <file>./usr/sbin/show_irq_affinity_hints.sh</file>
              <file>./usr/sbin/sysinfo-snapshot.py</file>
              <file>./usr/sbin/vendor_post_uninstall.sh</file>
              <file>./usr/sbin/vendor_pre_uninstall.sh</file>
              <file>./usr/sbin/vmad</file>
              <file>./usr/share/doc/packages/libibverbs</file>
              <file>./usr/share/doc/packages/libibverbs/libibverbs.md</file>
              <file>./usr/share/doc/packages/librdmacm</file>
              <file>./usr/share/doc/packages/librdmacm/librdmacm.md</file>
              <file>./usr/share/doc/packages/libvma-9.8.84</file>
              <file>./usr/share/doc/packages/libvma-9.8.84/CHANGES</file>
              <file>./usr/share/doc/packages/libvma-9.8.84/README</file>
              <file>./usr/share/doc/packages/mlnx-ofa_kernel</file>
              <file>./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules</file>
              <file>./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh</file>
              <file>./usr/share/doc/packages/mlnx-tools</file>
              <file>./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt</file>
              <file>./usr/share/doc/packages/perftest</file>
              <file>./usr/share/doc/packages/perftest/COPYING</file>
              <file>./usr/share/doc/packages/perftest/README</file>
              <file>./usr/share/doc/packages/perftest/runme</file>
              <file>./usr/share/doc/packages/rdma-core</file>
              <file>./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules</file>
              <file>./usr/share/doc/packages/rdma-core/README.md</file>
              <file>./usr/share/doc/packages/rdma-core/tag_matching.md</file>
              <file>./usr/share/doc/packages/rdma-core/udev.md</file>
              <file>./usr/share/licenses/libvma</file>
              <file>./usr/share/licenses/libvma/LICENSE</file>
              <file>./usr/share/licenses/mlnx-tools</file>
              <file>./usr/share/licenses/mlnx-tools/LICENSE</file>
              <file>./usr/share/licenses/rdma-core</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_FB</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_MIT</file>
              <file>./usr/share/licenses/rdma-core/COPYING.GPL2</file>
              <file>./usr/share/licenses/rdma-core/COPYING.md</file>
              <file>./usr/share/man/man1/ib_atomic_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_atomic_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_read_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_read_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_send_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_send_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_write_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_write_lat.1.gz</file>
              <file>./usr/share/man/man1/perftest.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_burst_lat.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_bw.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_fs_rate.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_lat.1.gz</file>
              <file>./usr/share/man/man7/rsocket.7.gz</file>
              <file>./usr/share/man/man7/vma.7.gz</file>
              <file>./usr/share/man/man8/ib2ib_setup.8.gz</file>
              <file>./usr/share/man/man8/mlnxofedctl.8.gz</file>
              <file>./usr/share/man/man8/rdma-ndd.8.gz</file>
              <file>./usr/share/man/man8/vmad.8.gz</file>
              <file>./usr/share/mlnx-tools/python/dcbnetlink.py</file>
              <file>./usr/share/mlnx-tools/python/netlink.py</file>
              <file>./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh</file>
              <file>./usr/share/mlnx_ofed/mlnx_drv_ctl</file>
              <file>./usr/share/mlnx_ofed/mod_load_funcs</file>
              <file>./usr/share/smartupdate/mlnx-ofa_kernel/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="8f24173ef2e740d2b110bb710e861366">
      <product_version>
        <id product="8f24173ef2e740d2b110bb710e861366" version="a03b3fe1be3845b8ada544044b206056" lucid_version="Gen10P_Gen11_Gen12_hpemrsa.rhel9.sles15.sles16@8.18.11.0__pubsw-linux_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="11"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)</alt_name_xlate>
        </alt_name>
        <version value="8.18.11.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,fr,it,de,es,ja">
          <languages_xlate lang="ja">英語（US）,フランス語,イタリア語,ドイツ語,スペイン語,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),French,Italian,German,Spanish,Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="02" hour="01" minute="50" second="24"/>
        <description>
          <description_xlate lang="ja"><![CDATA[HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. ]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>
	<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>
	<li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li>
	<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>
	<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>
	<li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>
	<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>
	<li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li>
	<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>
	<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>
	<li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">00B3</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0453</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="MRStorageAdministrator" guid="20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>MRStorageAdministrator-008.018.011.000-00.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="31MB" bytes="32772899" date_modified="2026-09-04T13:03:57" md5sum="783d428383f4c9ae6723f9b1003a62a4" sha1sum="0d2ca8638b220e896f9725cde802ab9b0fb29ef4" sha256sum="b2918f2f532dfaf0454bf55a1010f557577bd8d2d6954fed50aea9cbe6b1e799" sha512sum="870b65165ad5f87a21f2e672bb50ee4cfdfe2da4703103911416fc5d74dfd2426ea9fd2e9def4fabc70536da13afa266a53090af5b4dbf854e726d77155d7d2d" version="008.018.011.000" release="00">
            <name>MRStorageAdministrator-008.018.011.000-00.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/MRStorageAdministrator-008.018.011.000-00.x86_64.rpm</url>
            <file_list>
              <file>./etc/init.d/LsiSASH</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/LSA</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/report</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/README</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/97AB61D67CC8D4791C6CB34B01AEDD99.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/53EF515E4B68F4375CDAB62B8BF5DF72.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/59AE9E2C0EDDF3AAB8FA2CAAE04CA10B.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/2EE840FAFCB91D1EAD07D1F6BA3F09A2.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/B607368818C162A84762061F2C356C99.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/5F36DB58B87376D92AE07C107220CAFC.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/nginx</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/start.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/13</file>
              <file>./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6</file>
              <file>./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6.1</file>
              <file>./usr/lib/.build-id/25</file>
              <file>./usr/lib/.build-id/25/3a216f8a29433104fef3f5835f0f84b6acd10c</file>
              <file>./usr/lib/.build-id/27</file>
              <file>./usr/lib/.build-id/27/d4c42718119005429054dafd6f28c527daed04</file>
              <file>./usr/lib/.build-id/28</file>
              <file>./usr/lib/.build-id/28/86229857c741873f745a6f19d6bb88e78e9c23</file>
              <file>./usr/lib/.build-id/45</file>
              <file>./usr/lib/.build-id/45/c89dd0ed41481f5aaf71b6d0dfb5fe7e86b263</file>
              <file>./usr/lib/.build-id/49</file>
              <file>./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623</file>
              <file>./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623.1</file>
              <file>./usr/lib/.build-id/5e</file>
              <file>./usr/lib/.build-id/5e/d4b97581cb36c65a2a3ef7dd9793c9e434b982</file>
              <file>./usr/lib/.build-id/69</file>
              <file>./usr/lib/.build-id/69/67b5a6b52135a69585c5d4de37f594b81a8a23</file>
              <file>./usr/lib/.build-id/6c</file>
              <file>./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f</file>
              <file>./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f.1</file>
              <file>./usr/lib/.build-id/6f</file>
              <file>./usr/lib/.build-id/6f/25d39fe93fbce3ec7b9856fe40fba91b4088b3</file>
              <file>./usr/lib/.build-id/7a</file>
              <file>./usr/lib/.build-id/7a/06b1924c8e057bb3ab50b07e25eed5994d7961</file>
              <file>./usr/lib/.build-id/7f</file>
              <file>./usr/lib/.build-id/7f/48add33807fd524598438751c6e8824e076c3e</file>
              <file>./usr/lib/.build-id/84</file>
              <file>./usr/lib/.build-id/84/bc4a60fa08e959f9cdf5e9d0e14207e79d3dcd</file>
              <file>./usr/lib/.build-id/96</file>
              <file>./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd</file>
              <file>./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd.1</file>
              <file>./usr/lib/.build-id/a5</file>
              <file>./usr/lib/.build-id/a5/cab41eab92548c83894b5ab65b1099e676db7f</file>
              <file>./usr/lib/.build-id/c4</file>
              <file>./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a</file>
              <file>./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a.1</file>
              <file>./usr/lib/.build-id/d6</file>
              <file>./usr/lib/.build-id/d6/8f1a74a48ef91989b2522a2059876facfdf263</file>
              <file>./usr/lib/.build-id/db</file>
              <file>./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157</file>
              <file>./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157.1</file>
              <file>./usr/lib/.build-id/df</file>
              <file>./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986</file>
              <file>./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986.1</file>
              <file>./usr/lib/.build-id/e9</file>
              <file>./usr/lib/.build-id/e9/1af91e89e3823df3862e83bc337a10e311fb57</file>
              <file>./usr/lib/.build-id/eb</file>
              <file>./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce</file>
              <file>./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce.1</file>
              <file>./usr/lib/.build-id/f2</file>
              <file>./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3</file>
              <file>./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3.1</file>
              <file>./usr/lib/.build-id/f7</file>
              <file>./usr/lib/.build-id/f7/f1a06a9fd6ef397a21902d59cc0428a672f386</file>
              <file>./usr/share/smartupdate/MRStorageAdministrator/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="27053985f2354572a6633cc6a63bb7ef">
      <product_version>
        <id product="27053985f2354572a6633cc6a63bb7ef" version="26ed76e01e9a47fea5fd1b580a91601d" lucid_version="FWPKG-P42041-B21@26.49.1014(A)__fwpkg-generic_en"/>
        <different>new</different>
        <build number="2"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE</name_xlate>
          <name_xlate lang="en">NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE</alt_name_xlate>
          <alt_name_xlate lang="en">NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE</alt_name_xlate>
        </alt_name>
        <version value="26.49.1014" revision="A" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="24" hour="06" minute="52" second="41"/>
        <description>
          <description_xlate lang="ja"><![CDATA[NVIDIA HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE]]></description_xlate>
          <description_xlate lang="en"><![CDATA[NVIDIA HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKGは、アダプターにフラッシュされたファームウェアバージョンが20.27.1016以降の場合にのみ機能し、iLO5ファームウェアバージョンは2.30以降である必要があります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKG will work only if the firmware version flashed on the adapter is 20.27.1016 or later and iLO5 firmware version must be 2.30 or higher.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px">ローカルホストOSの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px">リモートの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li style="margin-left: 80px;">
	<p><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li style="margin-left: 80px;">
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3.  iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li style="margin-left: 80px;">
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li style="margin-left: 80px;">
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px">Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td>
			<td>26.49.1014</td>
			<td>MT_0000000551</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td>
			<td>26.49.1014</td>
			<td>MT_0000000551</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="6" minor="3" sr="OEM" name="Microsoft Windows Server 2012 R2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="6" minor="0" sr="OEM" name="Red Hat Enterprise Linux 6 Server (x86-64)"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="7" minor="0" sr="OEM" name="Red Hat Enterprise Linux 7 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="11" minor="0" sr="OEM" name="SUSE LINUX Enterprise Server 11 (AMD64/EM64T)"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="5" sr="OEM" name="VMware vSphere 6.5"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="7" sr="OEM" name="VMware vSphere 6.7"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="32000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="Mellanox_NIC_PLDM_MCX631432AS-ADAI" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7356602" date_modified="2026-08-27T12:13:18" md5sum="72f35ea4847e4201d09bcb690447d1d4" sha1sum="313745cff3a80c63db206cbb3be8bbc126629478" sha256sum="ac350ec06a178ba9a4498a67a1cf39d2c9a04004bae355ddbe788d4287bc32e8" sha512sum="adfefe221f94d7b4ce7714e1fbcc5762aca6bed02b44ea9fc86cfec75de4a295acd95590fa7c6c13a3c86b0e4eb122483916179927d8c1baab768d1e507fd4cc">
            <name>26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg</url>
            <file_list>
              <file>26_49_1014-MCX631432AS-ADA_Ax.pldm.signed</file>
              <file>26_49_1014-MCX631432AS-ADA_Ax.pldm.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>26_49_1014-MCX631432AS-ADA_Ax.pldm.signed</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-15b3-101f15b30007</Target>
              <Version>26.49.1014</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="1065be4a2b444fe1b0060c3a91fcbde2">
      <product_version>
        <id product="1065be4a2b444fe1b0060c3a91fcbde2" version="18b9052e60cc49108d9908996ae850c4" lucid_version="ixgbevf.rhel9@5.3.36-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9.</alt_name_xlate>
        </alt_name>
        <version value="5.3.36-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="53"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>    このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li>
</ul>

<p style="margin-left:40px">* 以前のWebリリースkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmは公開されていません<br />
    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf）から（ixgbevf）に変更されました。この変更を（ixgbevf）から（<strong>hp</strong>-ixgbevf）に戻しました。<br />
    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />
* kmod-<strong>hp</strong>-ixgbevfとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />
  混乱を避けるため、すでにkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbevfによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>&nbsp; &nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li>
</ul>

<p style="margin-left:40px">* The previous web release kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm is unpublished<br />
&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf) to (ixgbevf). Now we revert this change from (ixgbevf) to (<strong>hp</strong>-ixgbevf).<br />
&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />
* kmod-<strong>hp</strong>-ixgbevf and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />
&nbsp; To avoid confusion, if you already download and install kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbevf and then install the updated RPM.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-hp-ixgbevf" guid="20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-hp-ixgbevf" guid="20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="87KB" bytes="89312" date_modified="2026-09-02T13:57:57" md5sum="ed98f70b49bd93e59db4ed7ff36a0a7e" sha1sum="e7167d812d7e45b79cf80c0ca4e994231b61b791" sha256sum="a2f54e0d5c11271bd6382d5743e0fb19711feafda89fca8841da84bb69eceeb4" sha512sum="ed7fb91bfed2ccaf97a9f1b9f6fecbc37d5b1b91c4f432cfb42ee1b246b73ee4134a9da83d547e4525496c19da3812a7766e1a69236caa4d6d43eed8f92ca07f" version="5.3.36" release="1.rhel9u7">
            <name>kmod-hp-ixgbevf-5.3.36-1.rhel9u7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-hp-ixgbevf-5.3.36-1.rhel9u7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbevf.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbevf-oob.conf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf/ixgbevf.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/63</file>
              <file>./usr/lib/.build-id/63/43579768eb5a278445f4d87a9094944b44ff5d</file>
              <file>./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml</file>
            </file_list>
          </file>
          <file size="86KB" bytes="88409" date_modified="2026-09-02T14:02:11" md5sum="982c88a49b62198823ea05367fcbbbf2" sha1sum="7accf66f8ee80e4291c6c4a63a5a37b084bdf6a3" sha256sum="9891b70f2b1d475954554beadf3321cff849653de8ed04125534eb982d2af87e" sha512sum="1c121810c7f618e0806f2b386685cd825d1f86b6249f2850db1b3d21fb5408274f534b418a07b0f63b3a83e2d6cc3065c46e865c860747255af0d587b20629bd" version="5.3.36" release="1.rhel9u8">
            <name>kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbevf.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbevf-oob.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbevf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbevf/ixgbevf.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/f8</file>
              <file>./usr/lib/.build-id/f8/f8306776d9153c34a90189f0b372b7cc29ce7e</file>
              <file>./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="0883e4abd7344c9b834b5e5585107933">
      <product_version>
        <id product="0883e4abd7344c9b834b5e5585107933" version="a39a8a9e3aa149f89cefbd87d565aa7b" lucid_version="Gen10P_Gen11_StorCLI.linux@007.3811.0300__pubsw-linux_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator StorCLI for Linux 64ビット (for Gen10 PlusおよびGen11コントローラー)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">MegaRAID Storage Administrator StorCLI for Linux 64ビット </alt_name_xlate>
          <alt_name_xlate lang="en">MegaRAID Storage Administrator StorCLI for Linux 64-bit </alt_name_xlate>
        </alt_name>
        <version value="007.3811.0300" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,ja,de,fr,it,es">
          <languages_xlate lang="ja">英語（US）,日本語,ドイツ語,フランス語,イタリア語,スペイン語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese,German,French,Italian,Spanish</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="22"/>
        <description>
          <description_xlate lang="ja"><![CDATA[コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>STORCLIはRed Hat Package Manager（RPM）パッケージを用いて配布されます。</li>
	<li>古いバージョンのSTORCLIがシステムにインストールされている場合、"rpm -e storcli-<version>.noarch"を使用して最初にそれを削除してください。</li>
	<li>StorCLI RPMをインストールするには、rpm  -Uvh --oldpackage --replacefiles –replacepkgs <StorCLI-x.xx-x.noarch.rpm>コマンドを実行します。</li>
	<li>RPMに関する詳細については "man rpm" と入力します。</li>
	<li>ソフトウェアは/opt/MegaRAID/storcliにあり、実行可能ファイル名はstorcli64です。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li>
	<li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li>
	<li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li>
	<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>
	<li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="storcli" guid="20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>storcli-007.3811.0300-1.noarch.rpm</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="2880159" date_modified="2026-09-04T06:55:39" md5sum="92836c786c8d6aa2960e6f320682fcf3" sha1sum="078ddf9dae1aa33dc5bb142b77d2ea6ce1b98895" sha256sum="170131153c62e798ba7054af14aadd383a0248e3094ad5ea0ff3506986073cf3" sha512sum="b45c15ccd54c4db6c0121f04228f91a568c840dcf81a8b16ee9d314f1d548745834d3f811b8322d63eb8f9135a6e52f53d8ce99f73c381c55b23f795bc8e3cce" version="007.3811.0300" release="1">
            <name>storcli-007.3811.0300-1.noarch.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/storcli-007.3811.0300-1.noarch.rpm</url>
            <file_list>
              <file>./opt/MegaRAID/storcli/storcli</file>
              <file>./opt/MegaRAID/storcli/storcli64</file>
              <file>./usr/share/smartupdate/storcli/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="bd00d87f2270401aa892f5f48c2928c2">
      <product_version>
        <id product="bd00d87f2270401aa892f5f48c2928c2" version="ed4662ea9a1647f39dabf60c40a7024d" lucid_version="nicfwpkg_bcme_57412_2p10_baseT@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="12"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57412 BASE-T adapter</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57412 BASE-T adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57412 BASE-T adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57412 BASE-T adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 BASE-T Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 BASE-T Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57412 Ethernet 10Gb 2-port BASE-T Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57412 Ethernet 10Gb 2-port BASE-T Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57412_BASET_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957412P210TH00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1693966" date_modified="2026-08-18T05:39:16" md5sum="f764133800d8d7ad579da687082aa5b1" sha1sum="98095ae0a0bb98ef8d7979c880dd69ebf4f9b7dd" sha256sum="36dd4dd04566c9b2c08f51c477217dd6dbfac150d5f640aa7272884816e9b8b4" sha512sum="172eabd78fdecb5e0e72c855cc6d240810572e3e991077174334e314270b8908e2cf568885b8565787651aee906097b6bbc9a01019dc35dab7c41310cd0aa51b">
            <name>BCM238.1.169.0_BCM957412P210TH00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957412P210TH00.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957412P210TH00.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d614e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ee14e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ef14e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16dc14e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c114e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c514e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412P210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16bd14e4e120</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="e8f02987fae14861a37eb27a43adf117">
      <product_version>
        <id product="e8f02987fae14861a37eb27a43adf117" version="1673b76290904424a7eea2247b0ca3f7" lucid_version="Gen10P_Gen11_Gen12_hpemrsa.win.x64@8.18.11.0__sc-windows_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="11"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)</alt_name_xlate>
        </alt_name>
        <version value="8.18.11.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,fr,it,de,es,ja">
          <languages_xlate lang="ja">英語（US）,フランス語,イタリア語,ドイツ語,スペイン語,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),French,Italian,German,Spanish,Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="02" hour="01" minute="50" second="27"/>
        <description>
          <description_xlate lang="ja"><![CDATA[HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。
]]></description_xlate>
          <description_xlate lang="en"><![CDATA[The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.
]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>HPE MRSAの古いバージョンがシステムにインストールされている場合、"コントロールパネル ->プログラムのアンインストール"からアンインストールを行った後に、"LSA"をアンインストールしてください。</p>

<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>

<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>

<p>インストールボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>

<p> </p>

<p><strong>注記：</strong>ビルドがすでにインストールされているときに、ユーザーが同じバージョンのビルドを再度インストールしようとすると、動作が不安定になる可能性があります。既存のインストーラーに変更を加えるには、ビルドをアンインストールしてから再インストールすることをお勧めします。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p>

<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>

<p>From that drive and directory, execute the downloaded file.</p>

<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>

<p>&nbsp;</p>

<p><strong>NOTE: </strong>If user tries to install the same version of the build again when the build is already installed, the behavior can be erratic. Recommendation would be to un-install and install the build to make any changes to the existing installer.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>We use ALLUSERS=1 for Smart Component installations to ensure system‑level deployment (services and multi‑user support) and upgrade consistency; per Microsoft&#39;s Windows Installer documentation, MRSA shortcuts appearing for non‑administrator accounts are expected:&nbsp;<a href="https://learn.microsoft.com/en-us/windows/win32/msi/installation-context" rel="nofollow noopener" target="_blank">https://learn.microsoft.com/en-us/windows/win32/msi/installation-context</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>We use ALLUSERS=1 for Smart Component installations to ensure system‑level deployment (services and multi‑user support) and upgrade consistency; per Microsoft&#39;s Windows Installer documentation, MRSA shortcuts appearing for non‑administrator accounts are expected:&nbsp;<a href="https://learn.microsoft.com/en-us/windows/win32/msi/installation-context" rel="nofollow noopener" target="_blank">https://learn.microsoft.com/en-us/windows/win32/msi/installation-context</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">00B3</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0453</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="lsa.exe" guid="20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0">
              <sw_key_expectedpath>%programfiles%\HPEMRSA\LSIStorageAuthority\bin</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071446.exe</filename>
        <component_config/>
        <files>
          <file size="52MB" bytes="55232648" date_modified="2026-09-04T13:18:07" md5sum="8714f2c2882ae83a2cfa260c8ee9d009" sha1sum="8df0bc66f7ccfc9b1835a62c27243452456b7ebf" sha256sum="a06b30fd5f1dece7e902e98dac74285fe4fce5ce23c442b494c635572b813ccc" sha512sum="54ed2e45f88c988d996259e8cf9fee28ca980555295864a108d540e72b45d27c0c13f38f0de964f0764781c33073888a2bc312be1b173c79ed463a7af6064c78">
            <name>cp071446.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071446.exe</url>
            <file_list>
              <file>cp071446.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>HPE_Windows_readme.txt</file>
              <file>install.xml</file>
              <file>ISSetupPrerequisites/</file>
              <file>ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/</file>
              <file>ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe</file>
              <file>ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/</file>
              <file>ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe</file>
              <file>multisetup.dll</file>
              <file>setup.exe</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="c53410fa91a84d28bcd98b0f0f4e5926">
      <product_version>
        <id product="c53410fa91a84d28bcd98b0f0f4e5926" version="ea7d44c9adb64ae6adac48aecb41cbba" lucid_version="bnxt_roce.rhel10u2@238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="5"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 2.</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 2.</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 1.</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 1.</alt_name_xlate>
        </alt_name>
        <version value="238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 10 Update 1.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 10 Update 1.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10</em>, version 1.10.3-237.1.137.0 or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10</em>, version 1.10.3-237.1.137.0 or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="libbnxt_re" guid="20a6e8e4-bf33-4c71-a6bf-d9ecff04767d">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>libbnxt_re-238.1.165.0-rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="64KB" bytes="66495" date_modified="2026-09-03T04:17:53" md5sum="bf4d5fbd9c3fda810f7e9e161a11796f" sha1sum="b813e3c48e023fc7fb2106fbc7796310d634ded2" sha256sum="c47feb3867a9c0bf29cf1550a0172cac091498546c515b0f163b218d862cbdbe" sha512sum="e11e0893472fe300711eb84f7e18a967fb2c1def9263ee36561ab13caa62e4a98949b97a28301bd60ba61aa705f22e8e017ac9a394d9edaea3497c7a25522478" version="238.1.165.0" release="rhel10u2">
            <name>libbnxt_re-238.1.165.0-rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/libbnxt_re-238.1.165.0-rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/libibverbs.d/bnxt_re.driver</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/d0</file>
              <file>./usr/lib/.build-id/d0/6474161cf0657cf6cc7f05809ec69dc882f954</file>
              <file>./usr/lib64/libbnxt_re-238.1.165.0.so</file>
              <file>./usr/lib64/libbnxt_re-rdmav59.so</file>
              <file>./usr/lib64/libbnxt_re.so</file>
              <file>./usr/lib64/pkgconfig/libbnxt_re.pc</file>
              <file>./usr/share/smartupdate/libbnxt_re/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="7e0050d7cc724a879a45bb605213e3c8">
      <product_version>
        <id product="7e0050d7cc724a879a45bb605213e3c8" version="6c3b73e1421c41d38575a52bbf5dcf63" lucid_version="FWPKG_VR000960YYXPR@HPK2(C)__fwpkg-drive_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="universal-fw-drive"/>
        <name>
          <name_xlate lang="ja">ユニバーサルファームウェアパッケージforドライブ - VR000960YYXPR</name_xlate>
          <name_xlate lang="en">Universal Firmware Package for Drives -  VR000960YYXPR</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">ユニバーサルファームウェアパッケージforドライブ - VR000960YYXPR</alt_name_xlate>
          <alt_name_xlate lang="en">Universal Firmware Package for Drives - VR000960YYXPR</alt_name_xlate>
        </alt_name>
        <version value="HPK2" revision="C" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems/>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900357">
          <category_xlate lang="ja">Firmware - PCIe NVMe Storage Disk</category_xlate>
          <category_xlate lang="en">Firmware - PCIe NVMe Storage Disk</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="22" hour="02" minute="41" second="15"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージは、次のドライブモデルのファームウェアを提供します：VR000960YYXPR]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package provides firmware for the following drive models: VR000960YYXPR]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p>ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p>リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li>
	<p><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3. iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p><strong>Release Version and/or Date:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />
<strong>Last Recommended or Critical Version:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None<br />
<strong>Previous Version of Firmware:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None<br />
<strong>Enhancements/New Features:</strong></p>

<ul>
	<li>Add dual-signing support.</li>
	<li>Extend the drive FW installation time to 180 second.</li>
</ul>

<p><strong>Problems Fixed:</strong></p>

<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>

<p><strong>Known Issues:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p><strong>Release Version and/or Date:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />
<strong>Last Recommended or Critical Version:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None<br />
<strong>Previous Version of Firmware:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None<br />
<strong>Enhancements/New Features:</strong></p>

<ul>
	<li>Add dual-signing support.</li>
	<li>Extend the drive FW installation time to 180 second.</li>
</ul>

<p><strong>Problems Fixed:</strong></p>

<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>

<p><strong>Known Issues:</strong><br />
&nbsp;&nbsp;&nbsp;&nbsp; None</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="nvme">
                <supported_device_data name="id">VR000960YYXPR</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="5000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Environment Dependent">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot may be required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>180</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="VR000960YYXPR" guid="">
              <sw_key_expectedpath>firmware:sd:nvme</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>SKHynix_PE90X0_SED_KPE9010SHPK2.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="2004107" date_modified="2026-09-22T03:09:21" md5sum="e43b07b33b0231b04e4f0be2acf4d9a5" sha1sum="e39180292724bfdfe3e726d773c929bb02e31494" sha256sum="b8b1360ec52d601e026558738e19c3615662d7b025463b3a1f48b83dcc0a90da" sha512sum="7272eac6cadf1828a211ad38d5b008ec4b52ab2edc0f8bb54a1a8729b4854504b3f399b5dec9202c5c2e7a634bb88bf6eb14e43b9847cb0f3f3107550b65d31d">
            <name>SKHynix_PE90X0_SED_KPE9010SHPK2.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/SKHynix_PE90X0_SED_KPE9010SHPK2.fwpkg</url>
            <file_list>
              <file>payload.json</file>
              <file>SKHynix_PE90X0_SED_KPE9010SHPK2.HPb</file>
              <file>SKHynix_PE90X0_SED_KPE9010SHPK2.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>f6de0320-2e0f-489a-b238-6dd8ae7c3811</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>SKHynix-PE90X0_SED-NVMe</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>SKHynix_PE90X0_SED_KPE9010SHPK2.HPb</FileName>
                <InstallDurationSec>180</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>562340a5-3052-3030-3936-305959585052</Target>
              <Version>HPK2</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="35d3e33c9897431d88a9d5dce77685b3">
      <product_version>
        <id product="35d3e33c9897431d88a9d5dce77685b3" version="6ce52818655d4e61aaeb1a8aa77283c7" lucid_version="intel_cnv.w2k25@1.4.58.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="1"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Intel iceb Driver for Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">Intel iceb Driver for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel iceb Driver for Microsoft Windows Server 2025</alt_name_xlate>
          <alt_name_xlate lang="en">Intel iceb Driver for Microsoft Windows Server 2025</alt_name_xlate>
        </alt_name>
        <version value="1.4.58.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="01" hour="07" minute="11" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This Component Package contains the driver for HPE Intel iceb Gigabit Ethernet NICs running under Microsoft Windows Server 2025.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the driver for HPE Intel iceb Gigabit Ethernet NICs running under Microsoft Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="3200"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="iceb.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec3a22dd03">
              <sw_key_expectedpath>%systemroot%\system32\DriverStore\FileRepository\iceb.inf_amd64_0d313568beecbfb3</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073428.exe</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1747744" date_modified="2026-09-01T07:44:15" md5sum="6625dd88cb41db380df0cad7befb485b" sha1sum="9eeada64b3493355e762bd62308b2555b1c2f28a" sha256sum="3117cd1c3fd4f1e4fe0633ae604a8cd644cf8facf6d5e5f8a336fe42451b2cf7" sha512sum="93b515d69d06318ec61564e1380b7655f95f54813c167f35cde7dafb196b8ff1d6187c73857379f70908baf836853486ff0898d01aa4306773cec169f2909280">
            <name>cp073428.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073428.exe</url>
            <file_list>
              <file>cp073428.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>iceb.cat</file>
              <file>iceb.inf</file>
              <file>iceb.sys</file>
              <file>icebmsg.dll</file>
              <file>install.xml</file>
              <file>manifest_iceb.man</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="a00e6ed1db904ebf80004d7820172e46">
      <product_version>
        <id product="a00e6ed1db904ebf80004d7820172e46" version="76271aff95c6420cb01615efee33cf39" lucid_version="ice.rhel10@2.6.6-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Intel iceドライバーfor Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">Intel ice Drivers for Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel iceドライバーfor Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ice Drivers for Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="2.6.6-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="11"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 10で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 10.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-ice" guid="20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-ice" guid="20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-ice-2.6.6-1.rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1207886" date_modified="2026-09-02T08:31:30" md5sum="e349066b028cf7db8259cdcfab995fdd" sha1sum="b521de8a97bfafc87298467022af207f9b02c30d" sha256sum="d87c3936c70decc285e4dab403e17fae9f2b5cd3c7a79c7e4238404f366c0c88" sha512sum="f1865d740b6de06387fc59c57af007744635698f3d092225d26f309955143372a04c949280e2219ea701d4507c1fbd0479df30db73a902997576adc35a3529a6" version="2.6.6" release="1.rhel10u1">
            <name>kmod-ice-2.6.6-1.rhel10u1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ice-2.6.6-1.rhel10u1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ice.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ice/ice.ko</file>
              <file>./usr/share/doc/kmod-ice</file>
              <file>./usr/share/doc/kmod-ice/COPYING</file>
              <file>./usr/share/doc/kmod-ice/README</file>
              <file>./usr/share/doc/kmod-ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ice/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1208832" date_modified="2026-09-02T08:36:37" md5sum="50f6d77a52e8d9fd39838b9c705f6182" sha1sum="cfc622403682de1dabe59403eec11795d15bcb72" sha256sum="250a8d31aa76f0d0f1755e9d05a1dfde57d4e954ca5ff6c3989bb49b7e9dfbd0" sha512sum="4223a39547f8a91348b74ea0ec343cae8d583955ae7fc138f1c12ce828e73e407704072a185e45519c7bc089245ebe20c821b1686c7d2a333141b0b43ef11fbb" version="2.6.6" release="1.rhel10u2">
            <name>kmod-ice-2.6.6-1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ice-2.6.6-1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ice.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ice/ice.ko</file>
              <file>./usr/share/doc/kmod-ice</file>
              <file>./usr/share/doc/kmod-ice/COPYING</file>
              <file>./usr/share/doc/kmod-ice/README</file>
              <file>./usr/share/doc/kmod-ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ice/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="b27e4086749b43a09022b1ccf9b6e0c0">
      <product_version>
        <id product="b27e4086749b43a09022b1ccf9b6e0c0" version="7d4c1933a9a04d07941d18e4b7b85aba" lucid_version="ixgbe.rhel9@6.4.4-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9</alt_name_xlate>
        </alt_name>
        <version value="6.4.4-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="43"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li>
</ul>

<p style="margin-left:40px">* 以前のWebリリースkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmは公開されていません<br />
    - RPMパッケージ名は（<strong>hp</strong>-ixgbe）から（ixgbe）に変更されました。この変更を（ixgbe）から（<strong>hp</strong>-ixgbe）に戻しました。<br />
    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />
* kmod-<strong>hp</strong>-ixgbeとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />
  混乱を避けるため、すでにkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbeによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This component fallback the RPM format to old version for consistency in the same OS major version.</li>
</ul>

<p style="margin-left:40px">* The previous web release kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm is unpublished<br />
&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe) to (ixgbe). Now we revert this change from (ixgbe) to (<strong>hp</strong>-ixgbe).<br />
&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />
* kmod-<strong>hp</strong>-ixgbe and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />
&nbsp; To avoid confusion, if you already download and install kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbe and then install the updated RPM.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-hp-ixgbe" guid="20a6e8e4-bf33-4c71-a6bf-d9eccba99d79">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-hp-ixgbe" guid="20a6e8e4-bf33-4c71-a6bf-d9eccba99d79">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="381KB" bytes="390287" date_modified="2026-09-02T09:14:20" md5sum="76fb6cdcd0575614258ac5c0ad28237c" sha1sum="ddcbe5460564ae7cb95121a82d24001222543354" sha256sum="9f9f55cbf1d735c5e8c7ea52d9a6d28e38dd9356d6bdbae0072abd0d32a80a2f" sha512sum="8c271eac9e41d3b22ac0e8c1c2b9117b1b4fa2dd468a11a093c7706724d0af7b1d576043d59f8e41f55cc923c16a23f67a41d3e8ae9880334cd7b8f6bd6cb2a0" version="6.4.4" release="1.rhel9u7">
            <name>kmod-hp-ixgbe-6.4.4-1.rhel9u7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-hp-ixgbe-6.4.4-1.rhel9u7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbe.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbe-oob.conf</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe/ixgbe.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/01</file>
              <file>./usr/lib/.build-id/01/3b2a02fa853d5437909975b78dd6581b51d3ab</file>
              <file>./usr/share/smartupdate/kmod-hp-ixgbe/component.xml</file>
            </file_list>
          </file>
          <file size="375KB" bytes="384023" date_modified="2026-09-02T09:18:34" md5sum="9cf1d533d44bfb1354be5c0b740a6623" sha1sum="e87955c028782a3e09e3a871ba39e08607a9d4fa" sha256sum="1181891859e640b9fb36e7e21198d83fc3937cb8e478e737d52e5b12c8a1bfe3" sha512sum="5c27113a2df7915d0eca2a3d22b39b6387fabaf038c8455efaa351910f53f0b651e9a9a3b88039035ce15f76ecc5d0c3d7d2bb04eff2259c7c657fbb644e2309" version="6.4.4" release="1.rhel9u8">
            <name>kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbe.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbe-oob.conf</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbe</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbe/ixgbe.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/92</file>
              <file>./usr/lib/.build-id/92/f57ee87985ec4019cc2c352605143a5f221b23</file>
              <file>./usr/share/smartupdate/kmod-hp-ixgbe/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="435031f572ea43b79bd116d63a99a58a">
      <product_version>
        <id product="435031f572ea43b79bd116d63a99a58a" version="135e5222c6bf4449a335649d77cef286" lucid_version="nicfwpkg_bcme_57414_2p25@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57414アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57414 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57414アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57414 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57414 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57414_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957414A4142HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1464158" date_modified="2026-09-03T06:44:21" md5sum="2bae6a4735752f898773fefc1f9e391e" sha1sum="6517020805709ef78ec08c6963912518b615c80e" sha256sum="bdb95302db4945689bbf36b722fb5fafbc72f1ed9f35ac54a0aa5e52a2003369" sha512sum="f747a2b4f78dc63e62922f821156026122e19a756a3f2aed5e4956f9e54c597fa80823f6504149a3c21b69def09137df06d572ec29730fc97db86ee24fa249e9">
            <name>BCM238.1.169.0_BCM957414A4142HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957414A4142HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957414A4142HC.HPb</file>
              <file>BCM238.1.169.0_BCM957414A4142HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d714e41597</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ec14e41597</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ed14e41597</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="84f4d8cbba034646b75e0fce6c455870">
      <product_version>
        <id product="84f4d8cbba034646b75e0fce6c455870" version="310036dd60f245e88157295894305e07" lucid_version="broadcom_nx1.win64@221.0.10.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="2"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Broadcom NX1 1Gbドライバーfor Windows Server x64 Editions</name_xlate>
          <name_xlate lang="en">Broadcom NX1 1Gb Driver for Windows Server x64 Editions</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom NX1 1Gbドライバーfor Windows Server x64 Editions</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom NX1 1Gb Driver for Windows Server x64 Editions</alt_name_xlate>
        </alt_name>
        <version value="221.0.10.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントは、Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2022およびWindows Server 2025を含みます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>
	<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>
	<li>[インストール]ボタンをクリックして、インストールを開始します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>
	<li>From that drive and directory, execute the downloaded file.</li>
	<li>Click the &quot;Install&quot; button to proceed with the installation.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159C</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="600"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="b57nd60a.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072864.exe</filename>
        <component_config/>
        <files>
          <file size="949KB" bytes="971952" date_modified="2026-09-02T07:32:12" md5sum="df50ab370faf15008a2136253edee9b1" sha1sum="d2a1c76c72bebcec6541bd63b697ee2c1f3eb887" sha256sum="cff86ecdee1aa2bc6feecf58175412360296fba26fb0acd791b682dfb00c25c8" sha512sum="c677777f0b33b5cdb19b50408faaf6f737c2decf58cac2499b647d8fc0f5552e55c661ca60f5bcfbf984220db99e27756abefbbeb0383cebfe9a4f495ec66247">
            <name>cp072864.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072864.exe</url>
            <file_list>
              <file>b57nd60a.cat</file>
              <file>b57nd60a.inf</file>
              <file>b57nd60a.sys</file>
              <file>cp072864.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="fd79732b69c747a4ba4278e32ef12a49">
      <product_version>
        <id product="fd79732b69c747a4ba4278e32ef12a49" version="ac1b1f6b49d74f72919cc7f6fc4d63d2" lucid_version="broadcom_nxe.w2k25@238.1.110.0__sc-windows_en,ja"/>
        <different>new</different>
        <build number="9"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2025</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025</alt_name_xlate>
        </alt_name>
        <version value="238.1.110.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントには、Mircosoft Windows Server 2025用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the "Install" button to proceed with the installation.]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1819</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1760</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">16D6</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1819</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1819</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1819</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1819</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1808</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1808</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1809</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1809</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1806</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1751</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1806</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1806</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1807</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1807</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1808</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1809</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">181B</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="600"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="bnxtnd.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec919626a4">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072689.exe</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1123080" date_modified="2026-09-02T08:05:21" md5sum="ec63d71e94f10b4cb6c23603d72fab9e" sha1sum="6e895d128ccd0db821f5243c1b8e696adbcdbaff" sha256sum="b3623bdcaeb0971731551a6d44a50c3bd2adc55e411f4290b5bec7932bf59683" sha512sum="3380f664f09b8f9384c3c183d706496188d792a8c1e5ba748f8f2d5d96522c4eb60f3bead14a08df74d999e2568a49a06ed9418b21a64fed83f5b3a0ec93c7b4">
            <name>cp072689.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072689.exe</url>
            <file_list>
              <file>bnxtnd.cat</file>
              <file>bnxtnd.inf</file>
              <file>bnxtnd.sys</file>
              <file>cp072689.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="21fae56dffdc447eaf41f35779aa8197">
      <product_version>
        <id product="21fae56dffdc447eaf41f35779aa8197" version="5a84b9cfd8274122a891e84e06a6b2d8" lucid_version="nicfwpkg_bcme_57414_2p25_dr@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="9"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57414 SFP28 Dual Rate Adapter</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57414 SFP28 Dual Rate Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57414 SFP28 Dual Rate Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57414 SFP28 Dual Rate Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 SFP28 Dual Rate Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 SFP28 Dual Rate Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 Dual Rate Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 Dual Rate Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57414_DUALRATE_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957414A4142HDR.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1398894" date_modified="2026-08-18T06:11:13" md5sum="e9ee143a14fe8b686f10c3623799d83e" sha1sum="e97ef42b480445199cc342483ecaf00487f903d9" sha256sum="bc47ac347338bf73869b89609c10ce199aa11eeb1c4ff1e0496782afbd838483" sha512sum="ae8cb1fe034e128bcf2b940ac038798959810b60f1eb599987bb288853d653cff41f66cc1b8f19394598cc713f4e77914908c13eeddf3aa01432167f2e7e896f">
            <name>BCM238.1.169.0_BCM957414A4142HDR.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957414A4142HDR.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957414A4142HDR.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d714e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ec14e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ed14e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16dc14e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c114e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c514e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom BCM57414 DR Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414A4142HDR.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16bd14e4e122</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="6e4df08455db4ce3a3b07b6eecea6280">
      <product_version>
        <id product="6e4df08455db4ce3a3b07b6eecea6280" version="b8d1e080121f47f588b033e7ffbab6d9" lucid_version="amsd_rhel9@5.1.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="14"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 9 Server</name_xlate>
          <name_xlate lang="en">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 9 Server</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 9 Server</alt_name_xlate>
          <alt_name_xlate lang="en">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 9 Server</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and above, Embedded Health and Alerting.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and above, Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above, service providing SNMP support</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above, service providing SNMP support</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd-5.1.0-2197.8.rhel9.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="11MB" bytes="11987825" date_modified="2026-09-30T08:58:55" md5sum="9c3c691cd9ca283014cdcab148b446eb" sha1sum="5a9223dba116f159dde199883a00dce373fb7848" sha256sum="6fe6593319371eb7854eca774fa4cfc09ea596f3ea22eeebe5af1c36f34a737f" sha512sum="126dc6a9269a23c3befaad7623afbaaff3d2d043480cd02d16acb5131d569e42507d71d8d56e093a04f41e9698f04844e6856fa25c4cfe07e73e692bc6b7c291" version="5.1.0" release="2197.8.rhel9">
            <name>amsd-5.1.0-2197.8.rhel9.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd-5.1.0-2197.8.rhel9.x86_64.rpm</url>
            <file_list>
              <file>./etc/sysconfig/ahslog</file>
              <file>./etc/sysconfig/amsd</file>
              <file>./etc/sysconfig/amsd_rev</file>
              <file>./etc/sysconfig/cpqFca</file>
              <file>./etc/sysconfig/cpqFca_rev</file>
              <file>./etc/sysconfig/cpqIde</file>
              <file>./etc/sysconfig/cpqIde_rev</file>
              <file>./etc/sysconfig/cpqScsi</file>
              <file>./etc/sysconfig/cpqScsi_rev</file>
              <file>./etc/sysconfig/cpqiScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi_rev</file>
              <file>./etc/sysconfig/smad</file>
              <file>./etc/sysconfig/smad_rev</file>
              <file>./opt/amsd</file>
              <file>./opt/amsd/amsd.license</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/cpqiScsi</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/51</file>
              <file>./usr/lib/.build-id/51/12e33499e4b7cd784a542d295dadbb87d64fd9</file>
              <file>./usr/lib/.build-id/51/12e33499e4b7cd784a542d295dadbb87d64fd9.1</file>
              <file>./usr/lib/.build-id/5b</file>
              <file>./usr/lib/.build-id/5b/d5ffe124f36fbfc7d09a923d4168e40b4cf515</file>
              <file>./usr/lib/.build-id/5b/d5ffe124f36fbfc7d09a923d4168e40b4cf515.1</file>
              <file>./usr/lib/.build-id/60</file>
              <file>./usr/lib/.build-id/60/2ccdbca92ff67fbe7752b49a8b64502c804309</file>
              <file>./usr/lib/.build-id/b6</file>
              <file>./usr/lib/.build-id/b6/be2629743b8ed9c3a983b9f2d05a9220d1732f</file>
              <file>./usr/lib/.build-id/b6/be2629743b8ed9c3a983b9f2d05a9220d1732f.1</file>
              <file>./usr/lib/.build-id/b9</file>
              <file>./usr/lib/.build-id/b9/2090b1c033f69032cd066584fd187a6bc8b2e0</file>
              <file>./usr/lib/.build-id/b9/2090b1c033f69032cd066584fd187a6bc8b2e0.1</file>
              <file>./usr/lib/.build-id/ca</file>
              <file>./usr/lib/.build-id/ca/209976e8587f98232787e00cc0800cea0173a2</file>
              <file>./usr/lib/.build-id/d7</file>
              <file>./usr/lib/.build-id/d7/76cffd717856078cad4ed3dafc7cd963a0c7b1</file>
              <file>./usr/lib/.build-id/d7/76cffd717856078cad4ed3dafc7cd963a0c7b1.1</file>
              <file>./usr/lib/.build-id/f6</file>
              <file>./usr/lib/.build-id/f6/6a132269768201db263bd5845ab1f0fb668ca9</file>
              <file>./usr/lib/.build-id/f6/6a132269768201db263bd5845ab1f0fb668ca9.1</file>
              <file>./usr/lib/.build-id/fd</file>
              <file>./usr/lib/.build-id/fd/8a5f8df84ce0245466055429656abcc773e14f</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqFca_rev.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqIde_rev.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./usr/lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./usr/share/man/man8/ahslog.8.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqIde.8.gz</file>
              <file>./usr/share/man/man8/cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/smad.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqFca_rev</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqIde_rev</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqScsi_rev</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/mr_cpqScsi_rev</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="8737ae26e7954415ac1ce9fe455fdd07">
      <product_version>
        <id product="8737ae26e7954415ac1ce9fe455fdd07" version="5b736963fffd42808eaf7baad46a21c0" lucid_version="HPE_MR216i-o_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="8"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR216i-o Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR216i-o Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR216i-o Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR216i-o Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="33"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR216i-o Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR216i-o Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03291590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR216i-o_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521090" date_modified="2026-09-21T04:44:21" md5sum="c8620cd00ca71c3bdb7ad3ac231c8f9f" sha1sum="b319c06c9e0b2a22df36b6f0aaff455172bdd3e5" sha256sum="58a40c9e5b8753e05a06b1ac215a102e34fe6396c33acc1175bea2e9a60a163f" sha512sum="4ab1cf4c1d7e4d6de33cd7d3c186b42776112f21da529594a781af7e76fff339076b845d5a59de0d00c822e602ae5a41ee030a4d672a9507d62181489220c7e3">
            <name>HPE_MR216i-o_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR216i-o_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR216i-o_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR216i-o_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR216i-o_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR216i-o_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e215900329</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>52.26.3.5487</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="d9d151c798d94a31a9d263cef309ab70">
      <product_version>
        <id product="d9d151c798d94a31a9d263cef309ab70" version="47ba6f67f28344e6af845518e7c07784" lucid_version="ubuntu2404amsd@5.1.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="17"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service for Ubuntu 24.04 LTS</name_xlate>
          <name_xlate lang="en">Agentless Management Service for Ubuntu 24.04 LTS</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Agentless Management Service for Ubuntu 24.04 LTS</alt_name_xlate>
          <alt_name_xlate lang="en">Agentless Management Service for Ubuntu 24.04 LTS</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11447">
            <operating_system_xlate>Ubuntu 24.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service（AMSD）は、HPE Integrated Lights Out内蔵ヘルスおよびアラートのサポートを提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for HPE Integrated Lights-Out Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation method:</strong><br />
&nbsp;<br />
Using dpkg command<br />
To install the package, type:</p>

<ul>
	<li>dpkg -i amsd-&lt;version&gt;.deb</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul>
		<li>dpkg -i amsd-&lt;version&gt;.deb</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul>
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul>
		<li>man amsd</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation method:</strong><br />
&nbsp;<br />
Using dpkg command<br />
To install the package, type:</p>

<ul>
	<li>dpkg -i amsd-&lt;version&gt;.deb</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the DEB to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul>
		<li>dpkg -i amsd-&lt;version&gt;.deb</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul>
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul>
		<li>man amsd</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="ubuntu2404" major="24" minor="04" sr="OEM" name="Ubuntu 24.04 LTS"/>
          </supported_operating_systems>
          <supported_devices/>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:deb</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd_5.1.0-2197.8-ubuntu24_amd64.deb</filename>
        <component_config/>
        <files>
          <file size="8MB" bytes="9094922" date_modified="2026-09-30T13:56:27" md5sum="7fc2c98201330c17c727a96541309587" sha1sum="add3bdce3be02bc71262be7f2ad5668529637694" sha256sum="c00f473b10d302faeb1eea8e8fa117d7b3a4d1c0dede606ab7f50902bc98ec00" sha512sum="881c60450f2ee57d21e180b5ac1fbac668cdf025e5c82b1eaf2fa75914318303ef997d7398af4bf272694de56a588e2f3617224c0fe513204c389292f9d910c3" version="5.1.0" release="2197.8">
            <name>amsd_5.1.0-2197.8-ubuntu24_amd64.deb</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd_5.1.0-2197.8-ubuntu24_amd64.deb</url>
            <file_list>
              <file>./etc/default/ahslog</file>
              <file>./etc/default/amsd</file>
              <file>./etc/default/amsd_rev</file>
              <file>./etc/default/cpqIde</file>
              <file>./etc/default/cpqScsi</file>
              <file>./etc/default/cpqiScsi</file>
              <file>./etc/default/mr_cpqScsi</file>
              <file>./etc/default/smad</file>
              <file>./etc/default/smad_rev</file>
              <file>./lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqiScsi</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/share/amsd/amsd.license</file>
              <file>./usr/share/doc/amsd/README.Debian</file>
              <file>./usr/share/doc/amsd/changelog.Debian.gz</file>
              <file>./usr/share/doc/amsd/copyright</file>
              <file>./usr/share/man/man1/ahslog.1m.gz</file>
              <file>./usr/share/man/man1/smad.1m.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="4b7bb75be74941e8987c342978cb18f9">
      <product_version>
        <id product="4b7bb75be74941e8987c342978cb18f9" version="1d9c02a53cca48e78de42c3b2c241cac" lucid_version="nicfwpkg_bcme_57416_2p10@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="15"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57416アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57416 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57416アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57416 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57416 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57416_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957416A4162HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1645806" date_modified="2026-09-03T06:59:23" md5sum="f1b3f90a383f39ea399dfff9d15fb83d" sha1sum="3659913234ddf8eb130e1e688ab4c0b91034401c" sha256sum="ff8d1ddaa39f6d5df18e698d1be55b30bc2be927e02fbe57d73671386cd55f45" sha512sum="5b56d27becfd1e6ee86ce38484a469023e64a95c8794d59d0647b117139e93b9a3d6719feea9df756b6de793f158ebcaefbb37eb14a7cd91debc6afbfbff7564">
            <name>BCM238.1.169.0_BCM957416A4162HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957416A4162HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957416A4162HC.HPb</file>
              <file>BCM238.1.169.0_BCM957416A4162HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416A4162HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d814e41593</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416A4162HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ee14e41593</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416A4162HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ef14e41593</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="3779726b593149db9c97a7165f89d2e5">
      <product_version>
        <id product="3779726b593149db9c97a7165f89d2e5" version="659de3fed5eb4200acd862dc84f3c01e" lucid_version="ilo8.sanjac.chif.win2025.x64@4.8.1.0__sc-windows_en"/>
        <different>new</different>
        <build number="9"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">iLO8 Channel Interface Driver for Microsoft Windows Server 2025</name_xlate>
          <name_xlate lang="en">iLO8 Channel Interface Driver for Microsoft Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">iLO 8 Channel Interface Driver</alt_name_xlate>
          <alt_name_xlate lang="en">iLO 8 Channel Interface Driver</alt_name_xlate>
        </alt_name>
        <version value="4.8.1.0" revision="" type_of_change="0"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300032">
          <category_xlate lang="ja">ドライバ - システム マネジメント</category_xlate>
          <category_xlate lang="en">Driver - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[The iLO 8 Channel Interface Driver allows software to communicate with the iLO 8 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[The iLO 8 Channel Interface Driver allows software to communicate with the iLO 8 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>

<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>

<p>Click the &quot;Install&quot; button to perform the driver installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>

<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>

<p>Click the &quot;Install&quot; button to perform the driver installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Optional"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <supported_platforms>
            <supported_platform rom="A72"/>
          </supported_platforms>
          <required_diskspace size_kb="2000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Environment Dependent">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot may be required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="sanjacchif.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec7c7c8121">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="sanjacchif.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec7c7c8121">
              <sw_key_expectedpath>%systemroot%\system32\DriverStore\FileRepository\sanjacchif.inf_amd64_470fd87c6ceb8913</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071673.exe</filename>
        <component_config/>
        <files>
          <file size="564KB" bytes="577832" date_modified="2026-09-14T03:05:21" md5sum="5076f7ce6a9681096755c150ca61c8cb" sha1sum="1eee877348aaca11dd073461bc45a1e1ecf34970" sha256sum="d32240e3c29961f9fbf9a1a8f9e04bc0333dd0dabf13db4168304befce7774e5" sha512sum="d9d4e36d904b79253e0b95d49587888c504e790f3607c763b83395430ce253a9ceacf9762b12c241e623a17a3ee217d39bbddc09084c5f93d82e11e6c415a6ef">
            <name>cp071673.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071673.exe</url>
            <file_list>
              <file>cp071673.xml</file>
              <file>cpqsetup.exe</file>
              <file>generic.dll</file>
              <file>install.xml</file>
              <file>sanjacchif.cat</file>
              <file>sanjacchif.inf</file>
              <file>sanjacchif.sys</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="a5b53b4bfa36450dafe72d3912e27c73">
      <product_version>
        <id product="a5b53b4bfa36450dafe72d3912e27c73" version="386d43e38b534bcc872f726cfc192a59" lucid_version="ice.rhel9@2.6.6-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Intel iceドライバーfor Red Hat Enterprise Linux 9</name_xlate>
          <name_xlate lang="en">Intel ice Drivers for Red Hat Enterprise Linux 9</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel iceドライバーfor Red Hat Enterprise Linux 9</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ice Drivers for Red Hat Enterprise Linux 9</alt_name_xlate>
        </alt_name>
        <version value="2.6.6-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products/>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="12"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 9で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-ice" guid="20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-ice" guid="20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-ice-2.6.6-1.rhel9u8.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1190585" date_modified="2026-09-02T09:01:13" md5sum="00c0be118acfd7e0f55c7007de687d5c" sha1sum="07618cdfbf991507a41fb2a21a189167dbeac682" sha256sum="fcfed4fee3ac59fdf450708cdf8c814b7e1e4eff756844f84b4126e3ff6658bd" sha512sum="c94ac3a3aa17c197e23568fbf13273030bea18e37bc2ef4eb5029370be69efa5ac5d5cf8ed96ee48c97c66c5569372d70c69d4fd4810aa918e7fe9d62ada0939" version="2.6.6" release="1.rhel9u7">
            <name>kmod-ice-2.6.6-1.rhel9u7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ice-2.6.6-1.rhel9u7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/ice.conf</file>
              <file>./etc/dracut.conf.d/ice-oob.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice</file>
              <file>./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice/ice.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/71</file>
              <file>./usr/lib/.build-id/71/aef77c633db2ace36e7a818bc8be1fdbce2ffa</file>
              <file>./usr/share/doc/ice</file>
              <file>./usr/share/doc/ice/COPYING</file>
              <file>./usr/share/doc/ice/README</file>
              <file>./usr/share/doc/ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ice/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1175399" date_modified="2026-09-02T09:05:30" md5sum="3fe0da7a35a1c5ee16301e4ff13cbfff" sha1sum="d0a784dc5039167e154eff957779bb7f3d1ea121" sha256sum="20d592b611923d2b958052af619506e4e280a7eebcecdab56e99be0f1a11bcac" sha512sum="ea524b7029d588d0e5a7d5428b1bfa6c22ed19fd705914b564c86773ff016aa46faec8883e1799dcda1d878be583e9905d34e63c2341212c2f40e1a777cdc435" version="2.6.6" release="1.rhel9u8">
            <name>kmod-ice-2.6.6-1.rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ice-2.6.6-1.rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/ice.conf</file>
              <file>./etc/dracut.conf.d/ice-oob.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/ice</file>
              <file>./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/ice/ice.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/17</file>
              <file>./usr/lib/.build-id/17/5aa8808f0b50a58e8d94e49d28892d3480ec12</file>
              <file>./usr/share/doc/ice</file>
              <file>./usr/share/doc/ice/COPYING</file>
              <file>./usr/share/doc/ice/README</file>
              <file>./usr/share/doc/ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ice/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="3435b64680a240ef985cff616421b9f8">
      <product_version>
        <id product="3435b64680a240ef985cff616421b9f8" version="96179ab4a06442ddb9f015db6104dbe6" lucid_version="nicfwpkg_bcm_bcm5719@20.38.51__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom NX1ファームウェアパッケージfor BCM5719アダプター</name_xlate>
          <name_xlate lang="en">Broadcom NX1 Firmware Package for BCM5719 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom NX1ファームウェアパッケージfor BCM5719アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom NX1 Firmware Package for BCM5719 adapter</alt_name_xlate>
        </alt_name>
        <version value="20.38.51" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NX1 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NX1 Gigabit Ethernet NICs firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してFWPKGをフラッシュします</p>

<ol>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li><a href="https://support.hpe.com/">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</li>
	<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</li>
</ul>

<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p> </p>

<p>2. iLO GUIからのフラッシュ</p>

<ol>
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>サポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIで、[ファームウェア] に移動し、[iLOレポジトリにアップロード] を選択します。ファームウェアファイルを参照して、iLOレポジトリにアップロードします。</li>
	<li>iLOレポジトリで、メニューボタンをクリックして「インストール」を選択します。これにより、ファームウェアコンポーネントがインストールキューに追加されます。</li>
	<li>コンポーネントはインストールキューに追加されました。</li>
	<li>ファームウェアコンポーネントがインストールキューに存在する場合は、そのステータスを確認します。ステータスは「保留中」と表示されます。</li>
	<li>サーバーを再起動し、POSTページでファームウェアがフラッシュされているかどうかを確認します。</li>
	<li>ファームウェアのフラッシュと再起動後、インストールキューに戻り、ファームウェアコンポーネントのステータスが「完了」と表示されていることを確認します。</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the FWPKG using any below methods</p>

<ol>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO&nbsp;GUI</li>
</ol>

<p>1. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately.</p>

<p>&nbsp;</p>

<p>2.&nbsp;Flash from iLO&nbsp;GUI</p>

<ol>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the&nbsp;supported adapter is present in the server</li>
	<li>In the iLO GUI, navigate to Firmware, then select Upload to iLO Repository. Browse for the firmware file and upload it to the iLO repository.</li>
	<li>In the iLO Repository, click the menu button and select Install. This will add the firmware component to the installation queue.</li>
	<li>Go to the installation queue and verify that the firmware component has been added.</li>
	<li>If the firmware component is present in the installation queue, check its status, which should show as &quot;Pending&quot;.</li>
	<li>Reboot the server and verify on the POST page whether the firmware is being flashed.</li>
	<li>After the firmware flash and reboot, return to the installation queue and confirm that the firmware component status shows as &quot;Complete&quot;.</li>
</ol>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains combo image v20.38.51&nbsp;with the following firmware versions:</p>

<table border="1" cellpadding="2">
	<tbody>
		<tr>
			<td><strong>NIC</strong></td>
			<td><strong>Boot Code Version</strong></td>
			<td><strong>PXE Version</strong></td>
			<td><strong>NCSI Version</strong></td>
			<td><strong>UEFI Version</strong></td>
		</tr>
		<tr>
			<td>Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE</td>
			<td>1.68</td>
			<td>21.6.4</td>
			<td>1.5.77</td>
			<td>21.6.113</td>
		</tr>
	</tbody>
</table>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains combo image v20.38.51&nbsp;with the following firmware versions:</p>

<table border="1" cellpadding="2">
	<tbody>
		<tr>
			<td><strong>NIC</strong></td>
			<td><strong>Boot Code Version</strong></td>
			<td><strong>PXE Version</strong></td>
			<td><strong>NCSI Version</strong></td>
			<td><strong>UEFI Version</strong></td>
		</tr>
		<tr>
			<td>Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE</td>
			<td>1.68</td>
			<td>21.6.4</td>
			<td>1.5.77</td>
			<td>21.6.113</td>
		</tr>
	</tbody>
</table>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="NIC_NX1_5719_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM5719A1907HC-4x1G-20.38.51.fwpkg</filename>
        <component_config/>
        <files>
          <file size="548KB" bytes="561174" date_modified="2026-08-20T03:55:16" md5sum="5b0e931934ca06fc85d1f9d44fb92904" sha1sum="8f0ea998b0c23ff5cad0ad733141f7a226602da8" sha256sum="50f237ab44e6e4dc5322fd1a4057eb2db43286fd3285e001bc04c9603395148c" sha512sum="9cace0312cd91a69dfbae6a1ecc24bd104aed4f920766668c5f59652ecc89b6018b6f6a41c9640798da07a18cb071976ab5e8393aebd09ce1ffe6db67ece5dae">
            <name>BCM5719A1907HC-4x1G-20.38.51.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM5719A1907HC-4x1G-20.38.51.fwpkg</url>
            <file_list>
              <file>BCM5719A1907HC-4x1G-20.38.51.HPb</file>
              <file>BCM5719A1907HC-4x1G-20.38.51.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom BCM5719 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM5719A1907HC-4x1G-20.38.51.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-165714e41591</Target>
              <Version>20.38.51</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="5aad4922b5f54198b1d9a8e400dcfdda">
      <product_version>
        <id product="5aad4922b5f54198b1d9a8e400dcfdda" version="55d4008462cd4be5bc02f61173f060c9" lucid_version="Gen10P_Gen11_MR_Controller.sles15.x86_64.rpm@07.738.06.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="8"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusおよびMR416i-p、MR416i-o、MR216i-o、 MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバーfor 64ビットSUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusおよびMR416i-p、MR416i-o、MR216i-o、 MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバーfor 64ビットSUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit SUSE LINUX Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="07.738.06.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">LSI Logic Corporation</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">LSI Logic Corporation</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300214">
          <category_xlate lang="ja">ドライバ - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Driver - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="13"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このRPMを使用して、HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plus、およびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラーを有効にする、64ビットSUSE Linux Enterprise Server 15用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for SUSE LINUX Enterprise Server 15 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
To upgrade the driver, type the following command:<br />
# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
To upgrade the driver, type the following command:<br />
# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />
<br />
A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="lsi-megaraid_sas-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="lsi-megaraid_sas-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="943KB" bytes="966305" date_modified="2026-09-03T11:08:06" md5sum="129090099cebeee88cbdc5f030e10741" sha1sum="4697c2cb6e57b5db24e3088295f9f59649234bed" sha256sum="611d8e28b4ec21abc2d20aec6b4733be0cffb01a2b42ff9cf05f3bd07b238dfe" sha512sum="304977a153fd1f681a6c30b13d5dad3698e6d66d6e527168a12ce482e5d249d11b980e5f9e878873ba35b84d0a043c2477aba203fc543cea9474badb1cbd6211" version="07.738.06.0_sles15sp6" release="1">
            <name>lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp6-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp6-1.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/megaraid_sas.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/52</file>
              <file>./usr/lib/.build-id/52/2274da4e9d116021bf84327f8d1d51bcbb704d</file>
              <file>./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="927KB" bytes="949271" date_modified="2026-09-03T11:13:12" md5sum="99aa235f0a7e0287749a02c3cb1db284" sha1sum="fe33f9464db9934366a35d6f7e4527475fdde05b" sha256sum="dd011621520abfa49642c3d821c5d2d07b00b88b8762d1e08c77a1d46c045326" sha512sum="3d186caaaa31d3efdad3fdfe3c0448af2079ca186c4a470c55babca4c080df4d149b2495e6259d8a28abc4b96f1a0c60a1603ec7fec09dde90abda0934207ecd" version="07.738.06.0_sles15sp7" release="1">
            <name>lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/megaraid_sas.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/fa</file>
              <file>./usr/lib/.build-id/fa/a040e783710215b1d02ee9eb1fcffd2a529b9a</file>
              <file>./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="fc90f99dec3d4432a73ac738a336cdc1">
      <product_version>
        <id product="fc90f99dec3d4432a73ac738a336cdc1" version="8d2f7f926b6b48a4a5fa35568bee4aa3" lucid_version="amsd_rhel10@5.1.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="21"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 10 Server</name_xlate>
          <name_xlate lang="en">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 10 Server</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 10 Server</alt_name_xlate>
          <alt_name_xlate lang="en">Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 10 Server</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and above Embedded Health and Alerting.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and above Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above service providing SNMP support</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above service providing SNMP support</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd-5.1.0-2197.8.rhel10.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="11MB" bytes="11978946" date_modified="2026-09-30T09:00:11" md5sum="22571a9d09fc0a97d196a6da89005e09" sha1sum="c8bdafa680e90b06802a9109a9430a9a2367bfd6" sha256sum="248e9f03cfde476831a20e764ed5c9f430a32c98682b5f73615e88d2af3ed0a7" sha512sum="13b09aff29cf73333220cb635c003d8c3a87b00297ca711000f62deef7813c3be00504121f23211438b2bffbdb20975fe2e8d2354ac03d840cee03badcb3471b" version="5.1.0" release="2197.8.rhel10">
            <name>amsd-5.1.0-2197.8.rhel10.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd-5.1.0-2197.8.rhel10.x86_64.rpm</url>
            <file_list>
              <file>./etc/sysconfig/ahslog</file>
              <file>./etc/sysconfig/amsd</file>
              <file>./etc/sysconfig/amsd_rev</file>
              <file>./etc/sysconfig/cpqFca</file>
              <file>./etc/sysconfig/cpqFca_rev</file>
              <file>./etc/sysconfig/cpqIde</file>
              <file>./etc/sysconfig/cpqIde_rev</file>
              <file>./etc/sysconfig/cpqScsi</file>
              <file>./etc/sysconfig/cpqScsi_rev</file>
              <file>./etc/sysconfig/cpqiScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi_rev</file>
              <file>./etc/sysconfig/smad</file>
              <file>./etc/sysconfig/smad_rev</file>
              <file>./opt/amsd</file>
              <file>./opt/amsd/amsd.license</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/cpqiScsi</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/0b</file>
              <file>./usr/lib/.build-id/0b/0d7a6906b056bd4a56de172db3579041d1c4ea</file>
              <file>./usr/lib/.build-id/0b/0d7a6906b056bd4a56de172db3579041d1c4ea.1</file>
              <file>./usr/lib/.build-id/59</file>
              <file>./usr/lib/.build-id/59/923023b45852957d8dfed3aaf5008524ed223e</file>
              <file>./usr/lib/.build-id/59/923023b45852957d8dfed3aaf5008524ed223e.1</file>
              <file>./usr/lib/.build-id/71</file>
              <file>./usr/lib/.build-id/71/c93b3aabb92c83b21239ac65f501af7db5a634</file>
              <file>./usr/lib/.build-id/75</file>
              <file>./usr/lib/.build-id/75/5ec3e6b3009df57c6dc166209a47912f601112</file>
              <file>./usr/lib/.build-id/86</file>
              <file>./usr/lib/.build-id/86/4eef18b4bce47a4cf28b57b5a16c2c0e8f626d</file>
              <file>./usr/lib/.build-id/86/4eef18b4bce47a4cf28b57b5a16c2c0e8f626d.1</file>
              <file>./usr/lib/.build-id/9f</file>
              <file>./usr/lib/.build-id/9f/42e7d3e2bd7c04ef483a1c90f5e5f215f7be73</file>
              <file>./usr/lib/.build-id/9f/42e7d3e2bd7c04ef483a1c90f5e5f215f7be73.1</file>
              <file>./usr/lib/.build-id/cb</file>
              <file>./usr/lib/.build-id/cb/b40781e383a6f036155697b909edc2526d47d9</file>
              <file>./usr/lib/.build-id/cb/b40781e383a6f036155697b909edc2526d47d9.1</file>
              <file>./usr/lib/.build-id/fd</file>
              <file>./usr/lib/.build-id/fd/432790f6231df705632b82b47db627c979bb3e</file>
              <file>./usr/lib/.build-id/fe</file>
              <file>./usr/lib/.build-id/fe/c89126471bf249ecf9dfbcaddb0841008ae4cb</file>
              <file>./usr/lib/.build-id/fe/c89126471bf249ecf9dfbcaddb0841008ae4cb.1</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqFca_rev.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqIde_rev.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./usr/lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./usr/share/man/man8/ahslog.8.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqIde.8.gz</file>
              <file>./usr/share/man/man8/cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/smad.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqFca_rev</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqIde_rev</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqScsi_rev</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/mr_cpqScsi_rev</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="2ed4fb56e81f45b0b8ae601a61b78e6c">
      <product_version>
        <id product="2ed4fb56e81f45b0b8ae601a61b78e6c" version="a765554e2bd44d77a694c5bed2e794dc" lucid_version="bnxt.sles15@1.10.3-238.1.165.0__pubsw-linux_en"/>
        <different>changed</different>
        <build number="4"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="1.10.3-238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="bnxt_en-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ece34fd967">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="bnxt_en-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ece34fd967">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1289624" date_modified="2026-09-03T03:56:19" md5sum="fac7d76874fac75e67e71f3985085a61" sha1sum="51c4cd97fc6072a078ee316ae7bb4e2194c3bd7d" sha256sum="1e68b7d1a9fc1e52e7884111744c0ba6c4ff59edb2ab196092918093f0e331af" sha512sum="3be2658e044d92a7cc4fd42b2df3b8a815913ba31f3e19b2d1320d9023e88d123d464de599f5241e23b6f5f5109fe9d0c09cbaead38ed7794fce91fdcee44d09" version="1.10.3_k6.4.0_150600.21" release="238.1.165.0.sles15sp6">
            <name>bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-238.1.165.0.sles15sp6.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-238.1.165.0.sles15sp6.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/bnxt_en.ko</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/drivers</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/bnxt_en-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1304898" date_modified="2026-09-03T04:00:35" md5sum="1836fdce3a58f580a560ba0de2034baf" sha1sum="bff9e721893213cbb26b09a5e4b591d92fb617be" sha256sum="327e2d8cea9b33daf355deac4bff3d8b667b524d205c58da176667ff8e91255b" sha512sum="ff7a3fd27452efc9b9882863a9fdc88833354933645ab3f59300471f64d66ef6f0bb43b844f7c38cd1cfc519fdd36ec2aec8c5d76f528822b1a0bdf73616dc08" version="1.10.3_k6.4.0_150700.51" release="238.1.165.0.sles15sp7">
            <name>bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/bnxt_en.ko</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./usr/share/smartupdate/bnxt_en-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="41b320ad66f042c0996f23c6087a171e">
      <product_version>
        <id product="41b320ad66f042c0996f23c6087a171e" version="a1d49d88b95b4d258bfe7dbd6026e1a2" lucid_version="nicfwpkg_bcme_57412_2p10@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="7"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57412アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57412 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57412アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57412 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57412 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57412_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957412A4121HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1464225" date_modified="2026-09-03T06:42:18" md5sum="cba8fce727e8de646c780f97a6c09875" sha1sum="ceaeab5970f72d0d56aeae7952c75acce12d1e53" sha256sum="7e31d17c3184d9e277508b8fa018a79b3451bb320ef63730e7ddcb1753352f09" sha512sum="e8cecf0efc5a3ddc0c03056ed17f4608e28fd728c77b852a1140319588d2b7be548c979874ae900c6efdaaae5579b9493edf8f391a8ec1ac1d9727ac191dfb87">
            <name>BCM238.1.169.0_BCM957412A4121HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957412A4121HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957412A4121HC.HPb</file>
              <file>BCM238.1.169.0_BCM957412A4121HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412A4121HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d614e41595</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412A4121HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16de14e41595</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412A4121HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16eb14e41595</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="7a201554eb654a4fa5bf0b9e23666148">
      <product_version>
        <id product="7a201554eb654a4fa5bf0b9e23666148" version="514cf4556ff647d982607379f266c3d1" lucid_version="nicfwpkg_bcme_57416_2p10ocp@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="13"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57416 OCP3アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57416 OCP3 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57416 OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57416 OCP3 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57416 OCP3 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57416 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57416OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957416N4160HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1646295" date_modified="2026-09-03T07:00:15" md5sum="1eb70b386bc87c9e896550226cb7f9fc" sha1sum="33da959b74139d15bdb46a4691ce52617b971796" sha256sum="110ce103c34c5c327d546327e8e9ab8c2b705ae708f3fffcca9cf58821b50e9d" sha512sum="afdd24b6dccff25e76a26efa09a82da44fffd212944f7764b18b21ec9363ffc87ce29295571aa2533d09b6ad58270e3af834ab9caef83eca2f8962dbb60fe115">
            <name>BCM238.1.169.0_BCM957416N4160HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957416N4160HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957416N4160HC.HPb</file>
              <file>BCM238.1.169.0_BCM957416N4160HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416N4160HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d814e41592</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416N4160HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ee14e41592</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57416 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957416N4160HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ef14e41592</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="6d4e51e8b4c040cc80275ae447831403">
      <product_version>
        <id product="6d4e51e8b4c040cc80275ae447831403" version="beb24f23bf464c8bbeba55c82937a4d9" lucid_version="Gen10P_Gen11_StorCLI.win@7.3811.300.0__sc-windows_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="9"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator StorCLI for Windows 64ビット (Gen10PおよびGen11コントローラー用)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MegaRAID Storage Administrator StorCLI for Windows 64ビット</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit</alt_name_xlate>
        </alt_name>
        <version value="7.3811.300.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,fr,it,de,es,ja">
          <languages_xlate lang="ja">英語（US）,フランス語,イタリア語,ドイツ語,スペイン語,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),French,Italian,German,Spanish,Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="25"/>
        <description>
          <description_xlate lang="ja"><![CDATA[コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen10 PlusおよびGen11コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P and Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>ターゲットサーバーのWindowsオペレーティングシステムからStorcliユーティリティを実行するには：</strong></p>

<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>

<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>

<p>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>

<p>インストールが完了したら、コマンドプロンプト環境を実行し、%programfiles%\MR Storage Administrator\StorCLI\binフォルダーに移動し、Storcli64.exeユーティリティを実行します</p>

<p>例えば: <strong>Storcli64.exe /c0 show </strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p>

<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>

<p>From that drive and directory, execute the downloaded file.</p>

<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>

<p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\MR Storage Administrator\StorCLI\bin&nbsp;folder and execute Storcli64.exe utility</p>

<p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="6000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>300</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="storcli64.exe" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b">
              <sw_key_expectedpath>%programfiles%\MR Storage Administrator\StorCLI\bin</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071621.exe</filename>
        <component_config/>
        <files>
          <file size="3MB" bytes="3175440" date_modified="2026-09-04T06:56:20" md5sum="e6b4c0d3dd2bf8dcf9a58f7b3d70a2a4" sha1sum="5a7749e1ae2fdfbf89d446dfb15241c1e1892e86" sha256sum="5e116713f7f8f3725af1fb3dbfbfa000a89fa22a5370cf4c9aca67306509cb96" sha512sum="6fc57da3e0db9852ec292f66e473f12b648ce4bab8dfae8602a1599e5d9af2f91fb318e4afc7c112f27f5df28d8b1a0960fc7b9a30e0a61456c340d1ffee6e37">
            <name>cp071621.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071621.exe</url>
            <file_list>
              <file>cp071621.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>multisetup.dll</file>
              <file>StorCLI.msi</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="ada99fb833d94a8ba8e825827baed488">
      <product_version>
        <id product="ada99fb833d94a8ba8e825827baed488" version="7a065000b71c4b3e988b1f712a746d65" lucid_version="ams.gen11.above.win.x64@5.10.0.0__sc-windows_en,ja"/>
        <different>new</different>
        <build number="11"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service for Microsoft Windows x64 (Gen11 and Above)</name_xlate>
          <name_xlate lang="en">Agentless Management Service for Microsoft Windows x64 (Gen11 and Above)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Agentless Management Service</alt_name_xlate>
          <alt_name_xlate lang="en">Agentless Management Service</alt_name_xlate>
        </alt_name>
        <version value="5.10.0.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="04" hour="06" minute="39" second="10"/>
        <description>
          <description_xlate lang="ja"><![CDATA[OSレベルのAgentless Management情報とActive Health Systemのイベントで帯域外管理システムを提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Provides out of band management system with OS-level Agentless Management information and Active Health System events. ]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>The <em>Channel Interface Driver for Windows X64</em> must be installed prior to this component.</p>

<p>Microsoft SNMP Service must be enabled, if SMA (System Management Assistant) is enabled.</p>

<p><strong>For HPE servers with iLO7:</strong><br />
Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.<br />
&nbsp;</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>The <em>Channel Interface Driver for Windows X64</em> must be installed prior to this component.</p>

<p>Microsoft SNMP Service must be enabled, if SMA (System Management Assistant) is enabled.</p>

<p><strong>For HPE servers with iLO7:</strong><br />
Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.<br />
&nbsp;</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE Servers with iLO 7 and Later</strong></p>

<p>- These instructions apply to HPE Gen12 and later servers equipped with iLO 7 or later.</p>

<p>- HPE Agentless Management Service (AMS) uses the HPE iLO Virtual NIC (VNIC) to communicate with iLO.</p>

<p>- An iLO application account is required for VNIC communication.</p>

<p>- During installation, AMS can create the application account using the provided iLO credentials.</p>

<p>- The application account is stored securely in the system TPM.</p>

<p>- Application-account creation is a one-time configuration.</p>

<p>- AMS can also operate without an application account. In this mode, iLO credentials must be configured after every operating system or AMS service restart.</p>

<p><strong>Installation Methods:</strong></p>

<p><strong>Method 1: Interactive Installation</strong></p>

<p>- Place the Smart Component in a temporary directory and double-click it.</p>

<p>- Select **Install** to extract the component to a temporary location.</p>

<p>- Click **Install** to begin the service installation.</p>

<p>- When prompted, choose whether to create an iLO application account.</p>

<p>- If you choose to create an application account, provide the iLO username and password.</p>

<p>- If the credentials are invalid or VNIC communication is unavailable, application-account creation may fail.</p>

<p>- If account creation fails, create the application account after installation using `amscli`.</p>

<p>- If you do not create an account during installation, you can create one later using `amscli`.</p>

<p>&nbsp;</p>

<p><strong>Method 2: Silent Mode (Non interactive) Installation</strong></p>

<p>&nbsp;</p>

<p>- Install AMS using the following command:</p>

<p>&nbsp; &nbsp; &nbsp; cp&lt;xxxx&gt;.exe /silent</p>

<p>- In silent mode, SMA is installed but its service is not enabled.</p>

<p>- Enable the SMA service later by running:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;%ProgramFiles%\\OEM\\AMS\\Service\\EnableSma.bat&quot; /f</p>

<p>&nbsp;- The default installation path is typically:</p>

<p>&nbsp; &nbsp; &nbsp; C:\\Program Files\\OEM\\AMS\\Service</p>

<p>- After enabling SMA, use `amscli` to create an application account or configure iLO credentials.</p>

<p><br />
<strong>Create an Application Account</strong></p>

<p>- If application-account creation fails during installation, open a command prompt and run:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;C:\\Program Files\\OEM\\AMS\\Service\\amscli\\amscli.exe&quot; appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</p>

<p><br />
<strong>Configure iLO Credentials Without an Application Account</strong></p>

<p>- If you choose not to create an application account, configure the iLO credentials after every operating system or AMS service restart:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;C:\\Program Files\\OEM\\AMS\\Service\\amscli\\amscli.exe&quot; set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</p>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE Servers with iLO 7 and Later</strong></p>

<p>- These instructions apply to HPE Gen12 and later servers equipped with iLO 7 or later.</p>

<p>- HPE Agentless Management Service (AMS) uses the HPE iLO Virtual NIC (VNIC) to communicate with iLO.</p>

<p>- An iLO application account is required for VNIC communication.</p>

<p>- During installation, AMS can create the application account using the provided iLO credentials.</p>

<p>- The application account is stored securely in the system TPM.</p>

<p>- Application-account creation is a one-time configuration.</p>

<p>- AMS can also operate without an application account. In this mode, iLO credentials must be configured after every operating system or AMS service restart.</p>

<p><strong>Installation Methods:</strong></p>

<p><strong>Method 1: Interactive Installation</strong></p>

<p>- Place the Smart Component in a temporary directory and double-click it.</p>

<p>- Select **Install** to extract the component to a temporary location.</p>

<p>- Click **Install** to begin the service installation.</p>

<p>- When prompted, choose whether to create an iLO application account.</p>

<p>- If you choose to create an application account, provide the iLO username and password.</p>

<p>- If the credentials are invalid or VNIC communication is unavailable, application-account creation may fail.</p>

<p>- If account creation fails, create the application account after installation using `amscli`.</p>

<p>- If you do not create an account during installation, you can create one later using `amscli`.</p>

<p>&nbsp;</p>

<p><strong>Method 2: Silent Mode (Non interactive) Installation</strong></p>

<p>&nbsp;</p>

<p>- Install AMS using the following command:</p>

<p>&nbsp; &nbsp; &nbsp; cp&lt;xxxx&gt;.exe /silent</p>

<p>- In silent mode, SMA is installed but its service is not enabled.</p>

<p>- Enable the SMA service later by running:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;%ProgramFiles%\\OEM\\AMS\\Service\\EnableSma.bat&quot; /f</p>

<p>&nbsp;- The default installation path is typically:</p>

<p>&nbsp; &nbsp; &nbsp; C:\\Program Files\\OEM\\AMS\\Service</p>

<p>- After enabling SMA, use `amscli` to create an application account or configure iLO credentials.</p>

<p><br />
<strong>Create an Application Account</strong></p>

<p>- If application-account creation fails during installation, open a command prompt and run:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;C:\\Program Files\\OEM\\AMS\\Service\\amscli\\amscli.exe&quot; appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</p>

<p><br />
<strong>Configure iLO Credentials Without an Application Account</strong></p>

<p>- If you choose not to create an application account, configure the iLO credentials after every operating system or AMS service restart:</p>

<p>&nbsp; &nbsp; &nbsp; &quot;C:\\Program Files\\OEM\\AMS\\Service\\amscli\\amscli.exe&quot; set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</p>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li>
	<li>ユーザーはAMSのインストール後にコード整合性ポリシーを有効にすることを推奨します。</li>
	<li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li>
	<li>iLO6暗号化がSuiteB NSAモードに設定されているときは、AMSコントロールパネルアプレットの[SNMP]タブに<br />
	  SNMP設定が表示されず、テストトラップ生成が許可されません。  iLO6->マネジメントページを代替オプションとして使用してください</li>
	<li>AMSは、Windowsタスクマネージャーでゆっくりとしたメモリ消費量の増加を示す場合があります。これは、Microsoft WindowsのWMI（Windows Management Instrumentation）の既知の問題によるものです。今後のMicrosoft Windowsのアップデートまたはバージョンで修正される予定です。メモリ消費を遅くするには、次のいずれかを実行します。</li>
</ul>

<p>             1. AMSサービスを再起動します（コマンドプロンプトで'net stop ams'と入力し、次に'net start ams'と入力します）...または...</p>

<p>             2. レジストリのHKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\hpeams\ParametersにPollIntervalという名前の新しいDWORDレジストリ値を作成し、その値を10進数の300より大きい値に設定します。この値により、AMSがWMIからデータを読み取る頻度（秒単位）が決定されます。</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li>
	<li>Recommend user enables code integrity policy after AMS installed.</li>
	<li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li>
	<li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />
	&nbsp; when iLO6&nbsp;encryption is set to SuiteB NSA mode.&nbsp; Please use iLO6-&gt;Management page as an alternate option</li>
	<li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li>
</ul>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\hpeams\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" name="Microsoft Windows 10 (64bit, version 1809 &amp; later)"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows 10 (64bit, version 1803 &amp; older)"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <supported_platforms>
            <supported_platform rom="U66"/>
            <supported_platform rom="U69"/>
            <supported_platform rom="U59"/>
            <supported_platform rom="U83"/>
            <supported_platform rom="U54"/>
            <supported_platform rom="I45"/>
            <supported_platform rom="A56"/>
            <supported_platform rom="A55"/>
            <supported_platform rom="U43"/>
            <supported_platform rom="U63"/>
            <supported_platform rom="U74"/>
            <supported_platform rom="I46"/>
            <supported_platform rom="U72"/>
            <supported_platform rom="A58"/>
            <supported_platform rom="U57"/>
            <supported_platform rom="U70"/>
            <supported_platform rom="U77"/>
            <supported_platform rom="U68"/>
            <supported_platform rom="H11"/>
            <supported_platform rom="A66"/>
            <supported_platform rom="U62"/>
            <supported_platform rom="U65"/>
            <supported_platform rom="U58"/>
            <supported_platform rom="U71"/>
            <supported_platform rom="A72"/>
          </supported_platforms>
          <required_diskspace size_kb="5000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params>/verbose_log</command_params>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>300</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ams.exe" guid="20a6e8e4-bf33-4c71-a6bf-d9ec8b303467">
              <sw_key_expectedpath>%ProgramFiles%\OEM\AMS\service</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072928.exe</filename>
        <component_config/>
        <files>
          <file size="25MB" bytes="26715664" date_modified="2026-09-16T10:19:00" md5sum="15dbc28c10cc909fb2ebc4375f23f5c4" sha1sum="4bec04064002a1ebf61624f459117bcf648e3fd3" sha256sum="c55ff9932b9f7988a27802141c28eee4dcf66bef44805a7a828d823388027cf7" sha512sum="99af2f8b64c39d32f155c716d9f073aa412feb5d53fd10f53787e8d5fd06d76ca855db3435bd7878e24d5192aa68e8838f34849bba54caca5c2662fa3ab74053">
            <name>cp072928.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072928.exe</url>
            <file_list>
              <file>ams.cab</file>
              <file>ams.msi</file>
              <file>cp072928.xml</file>
              <file>cpqsetup.exe</file>
              <file>install.xml</file>
              <file>multisetup.dll</file>
              <file>SmaInstall.cab</file>
              <file>VC_redist.x64.exe</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="ffe236b3c9414886ad6bebd19a87b8d3">
      <product_version>
        <id product="ffe236b3c9414886ad6bebd19a87b8d3" version="3cde163bc7ed48218f359b695edcb86b" lucid_version="nicfwpkg_bcme_57608_2p100@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57608 100GbE 2pアダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57608 100GbE 2p Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57608 100GbE 2pアダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57608 100GbE 2p Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57608 100GbE 2p Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57608 100GbE 2p Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 Adapter for HPE</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 Adapter for HPE</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.154.0</td>
				<td colspan="1" rowspan="7">238.1.168.0</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57608_2P100_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957608-P2100HQF00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="3MB" bytes="3684050" date_modified="2026-08-18T06:42:14" md5sum="c836a340f71972897a2c04b970b8523d" sha1sum="bdf7fc682060fd6d4e91f948a8be07406154ef9a" sha256sum="42aeeb6557c417761a84c41a7fa0e655e14d32acc262aeb6e9d870529ebec5c5" sha512sum="8e20099a8ff9ae595274d6b2a23d570ba9c4c9a10e4d43c57b67f2d14b310f2da7f946840b75455654df8be1baa406e600f6370040d69a14c1947a9cdcbeec7f">
            <name>BCM238.1.169.0_BCM957608-P2100HQF00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957608-P2100HQF00.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957608-P2100HQF00.HPb</file>
              <file>BCM238.1.169.0_BCM957608-P2100HQF00.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57608 100GbE 2p QSFP112 Adptr</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957608-P2100HQF00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-176014e4e124</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="2e783bb79a1d489d9f42398711c931ef">
      <product_version>
        <id product="2e783bb79a1d489d9f42398711c931ef" version="89fd436745be41c68dc2c6f91e3d6ef0" lucid_version="ixgbevf.rhel10@5.3.36-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbevfドライバーfor Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbevfドライバーfor Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="5.3.36-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="52"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-ixgbevf" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2eb7029e">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-ixgbevf" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2eb7029e">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="112KB" bytes="115297" date_modified="2026-09-02T10:34:56" md5sum="36b061fa93f39cf1cf6658f06b655b56" sha1sum="3dc3e2b06e40a01db5699632d8ebe170715adcbe" sha256sum="6680af534f015672b5ce4a55a0294652793fab63a402d857695dfe3f3d9ffb16" sha512sum="243b9c83366b240bcca5fbd36d71278506633c26657d7a16f926dfcacf0b54afbbc08412040040c0eaad7bef2a2cc13e45e0ba9a5d2416fe7613f777f7c15f57" version="5.3.36" release="1.rhel10u1">
            <name>kmod-ixgbevf-5.3.36-1.rhel10u1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ixgbevf-5.3.36-1.rhel10u1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ixgbevf.conf</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ixgbevf/ixgbevf.ko</file>
              <file>./usr/share/doc/kmod-ixgbevf</file>
              <file>./usr/share/doc/kmod-ixgbevf/COPYING</file>
              <file>./usr/share/doc/kmod-ixgbevf/README</file>
              <file>./usr/share/doc/kmod-ixgbevf/pci.updates</file>
              <file>./usr/share/man/man7/ixgbevf.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ixgbevf/component.xml</file>
            </file_list>
          </file>
          <file size="112KB" bytes="115183" date_modified="2026-09-02T10:39:09" md5sum="79c266f69bba1aab806602aa91e8bfc3" sha1sum="084d2125eb7bbeb3d4599aed5b308af5184c3bc0" sha256sum="db11bc82f020db3afbb23744b656c46e76c3052cbcaf068dc01599639558af20" sha512sum="4177271b9a71d8080edce287f6dee9403b5d59cdccc3030d0a06d36353f2f725947bbaef6a8e0f7c6a93c699fdfa949ab8e1245f3001ff52841b4b84bee006b5" version="5.3.36" release="1.rhel10u2">
            <name>kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ixgbevf.conf</file>
              <file>./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ixgbevf/ixgbevf.ko</file>
              <file>./usr/share/doc/kmod-ixgbevf</file>
              <file>./usr/share/doc/kmod-ixgbevf/COPYING</file>
              <file>./usr/share/doc/kmod-ixgbevf/README</file>
              <file>./usr/share/doc/kmod-ixgbevf/pci.updates</file>
              <file>./usr/share/man/man7/ixgbevf.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ixgbevf/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="b8cab2acffab4f63833f5213954deee9">
      <product_version>
        <id product="b8cab2acffab4f63833f5213954deee9" version="802e5ac9fc754e81bd7847be5fc8a0a4" lucid_version="HPE_MR416i-p_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR416i-p Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR416i-p Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="51"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR416i-p Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR416i-p Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03251590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR416i-p_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521089" date_modified="2026-09-21T04:44:17" md5sum="b612ec9529ee4966f92d8a59e8b65f41" sha1sum="c8d726506b8a22e4e986f89ee2ea3f2fd85d3167" sha256sum="03ef1458588d736ad800e6d2fdf1321986f5d0714c4cb89ae6dbca985ac0ed6f" sha512sum="86de07ac863deee472db8605e07eb9996d90da13bc8c8ddb4fc5f714386c05dce5be14999fc8eaf18c0a1fdb13d695cd7196870b0c250a7cba93947139771a4a">
            <name>HPE_MR416i-p_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR416i-p_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR416i-p_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR416i-p_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR416i-p_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR416i-p_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e215900325</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>52.26.3.5487</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="3d28404b009047cd9c6ade47efd24ca6">
      <product_version>
        <id product="3d28404b009047cd9c6ade47efd24ca6" version="b7ceedab021948ba927b1f34cd4fb0eb" lucid_version="nicfwpkg_bcme_57504_4p25ocp@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="18"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57504 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57504 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57504 OCP Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 OCP Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 235.1.160.0 and prior versions, please use Broadcom Firmware Package for BCM5750x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5750x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3" target="_blank">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 235.1.160.0 and prior versions, please use Broadcom Firmware Package for BCM5750x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5750x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3" target="_blank">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57504OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957504-N425H.fwpkg</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="3003247" date_modified="2026-09-16T08:05:19" md5sum="014285078f39c248188bfa045eab4d2e" sha1sum="fba167d84c225dbd9f9446e11a9789b19235d366" sha256sum="a480f93dee66be5f23df87d92d194472a8093e722e03bf07d98115ae35abe646" sha512sum="423de8401a704f964db5d7e06c3db90fb1946d817b72bcc250105517534c7c03f1d0c6dcae0d96007000cf57109038c9d8f4d4325aeb63ff2c1d2eebe3c9a0ce">
            <name>BCM238.1.169.0_BCM957504-N425H.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957504-N425H.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957504-N425H.HPb</file>
              <file>BCM238.1.169.0_BCM957504-N425H.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-N425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-175114e41598</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-N425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-180114e41598</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-N425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-180414e41598</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="f252c6b5c1e84f4b9ef7dd9047d97690">
      <product_version>
        <id product="f252c6b5c1e84f4b9ef7dd9047d97690" version="0de1b5beae82470eba37fe899d7b2665" lucid_version="nicfwpkg_intel_e835_xxv2ocp@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="5"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter </name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter </name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="28" hour="08" minute="41" second="27"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA2 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA2 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE</td>
			<td>80018D09</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE</td>
			<td>80018D09</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_XXV2OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_XXVDA2_OCP_2p10_NCSI_80018D09.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794289" date_modified="2026-08-18T07:33:17" md5sum="4063dba709dc4556babaaaa9b978a14c" sha1sum="2bec37a34dad1086e28b31f40e085b022f15fa8e" sha256sum="9b8f0261eff484b65ddcc7368bdc7bdb3bdbb516b9648e0b85335d91daf0b045" sha512sum="353bc1800b691e31ac249f3ffe4be24679f35b78ec685e95363a3d6c3d59943bb64295d1377d7f76c85bec1868f3f6421f8ad86b821dcf0779e7fd673816e120">
            <name>HPE_E835_XXVDA2_OCP_2p10_NCSI_80018D09.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_XXVDA2_OCP_2p10_NCSI_80018D09.fwpkg</url>
            <file_list>
              <file>HPE_E835_XXVDA2_OCP_2p10_NCSI_80018D09.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-XXVDA2 OCP adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_XXVDA2_OCP_2p10_NCSI_80018D09.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124a80860001</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="ba4eb47a98fe46cab9755c16c992ab61">
      <product_version>
        <id product="ba4eb47a98fe46cab9755c16c992ab61" version="cc86277813bb4655ab81bb10d5371dc0" lucid_version="nicfwpkg_intel_e835_xxv4ocp@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="11"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="07" day="01" hour="06" minute="30" second="01"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA4 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA4 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td>
			<td>80018D55</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td>
			<td>80018D55</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_XXV4OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_XXVDA4_OCP_2p10_NCSI_80018D55.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794289" date_modified="2026-08-18T07:54:13" md5sum="b3d89421b0e2bababe5ab04d871e844a" sha1sum="ebefdc19d242bf98365a93c01a49f0ce158ead18" sha256sum="417396079cdbc847476b681d73adb499854bf4bb38777d9c3f7844834e1e7c07" sha512sum="8d8c5a1ff1d0a93f805ee890f615548b740087434faf96a9c2282de89882597d7de3ff3a341d932983179b2998df29475e203a703ff6d9759ebb13e45ebc5894">
            <name>HPE_E835_XXVDA4_OCP_2p10_NCSI_80018D55.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_XXVDA4_OCP_2p10_NCSI_80018D55.fwpkg</url>
            <file_list>
              <file>HPE_E835_XXVDA4_OCP_2p10_NCSI_80018D55.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-XXVDA4 OCP adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_XXVDA4_OCP_2p10_NCSI_80018D55.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124a80860004</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="a4dfe483f7df4c3993a498bb13f08613">
      <product_version>
        <id product="a4dfe483f7df4c3993a498bb13f08613" version="6a79b38ffa4f4bab94ad18f163511a29" lucid_version="nicfwpkg_bcme_57414_2p25ocp@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57414 OCP3アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57414 OCP3 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57414 OCP3アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57414 OCP3  adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57414 OCP3 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57414 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_957414OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957414N4140HC.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1464399" date_modified="2026-09-03T06:59:20" md5sum="e0baf8239a7526ce79507dceff08b949" sha1sum="15cb91966d9943a16f46cae50084ad5b355721eb" sha256sum="e9c9a5600712519b04763937f5b477d1e94ec2553f7f8efb8076224a140eb7ee" sha512sum="cf4dd7a2bb8805580bcb7af0778ddac33ec640ce81241893f5ddf76c28c8bc1d821613e0a4c955d83df249ad1c76b337fb982aeb9fae0da8480bf33b2fc64574">
            <name>BCM238.1.169.0_BCM957414N4140HC.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957414N4140HC.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957414N4140HC.HPb</file>
              <file>BCM238.1.169.0_BCM957414N4140HC.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d714e41596</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ec14e41596</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57414 OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957414N4140HC.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ed14e41596</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="6abc17177caa45a4aec088b773a3169a">
      <product_version>
        <id product="6abc17177caa45a4aec088b773a3169a" version="73016440f1bb436291ba4dd6304f1bb5" lucid_version="nicfwpkg_intel_e835_cq2ocp@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="10"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="07" day="01" hour="06" minute="30" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-CQDA2 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-CQDA2 OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-CQDA2&nbsp;Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td>
			<td>80018D05</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-CQDA2&nbsp;Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td>
			<td>80018D05</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_CQ2OCP_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_CQDA2_OCP_2p10_NCSI_80018D05.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794287" date_modified="2026-08-18T07:33:50" md5sum="c663a62509e7345114db73410cb2ad31" sha1sum="4db87a8dd359ae469d3c6c4a623f24d53b44b352" sha256sum="f6d8a68d6371d3b6a56e0ff0015ea282632782cfe0678ddb4ff75a8f78d78ed5" sha512sum="b1026314be2657d4356d8c689802943881f8db7ab926a7b748769b7320dac8db82e6519349bcf8933369b8a2e95834791a3f4b9fba18cb06d7611b45dc142f2e">
            <name>HPE_E835_CQDA2_OCP_2p10_NCSI_80018D05.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_CQDA2_OCP_2p10_NCSI_80018D05.fwpkg</url>
            <file_list>
              <file>HPE_E835_CQDA2_OCP_2p10_NCSI_80018D05.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-CQDA2 OCP adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_CQDA2_OCP_2p10_NCSI_80018D05.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124980860002</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="dfe88bac1a1c43c48360fbb60f267282">
      <product_version>
        <id product="dfe88bac1a1c43c48360fbb60f267282" version="8457e49b96d6497790118526209f9b8b" lucid_version="mlnx_en_roce_mlx5.rhel10u2x86_64.rpm@26.04__pubsw-linux_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 2 (x86_64)</name_xlate>
          <name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 2 (x86_64)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 2 (x86_64)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 2 (x86_64)</alt_name_xlate>
        </alt_name>
        <version value="26.04" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett-Packard Development Company, L.P.</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="24" hour="07" minute="18" second="14"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 Lx and above adapters.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM contains HPE Tested and Approved Linux based Mellanox RoCE driver for ConnectX-4 Lx and above adapters.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>Install&nbsp;<strong>chkconfig&nbsp;</strong>from respective OS repository prior to install the RoCE pakage.</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>Install&nbsp;<strong>chkconfig&nbsp;</strong>from respective OS repository prior to install the RoCE pakage.</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26-04&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />
<br />
To install or upgrade the driver:<br />
If using kernel version 6.12.0-211.7.3.el10_2.x86_64&nbsp;or any future errata:<br />
<br />
<strong># rpm -Uvh kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />
<br />
<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-26-04&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />
<br />
To install or upgrade the driver:<br />
If using kernel version 6.12.0-211.7.3.el10_2.x86_64&nbsp;or any future errata:<br />
<br />
<strong># rpm -Uvh kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm</strong><br />
<br />
Setup is now complete. Reboot your computer for the driver to take effect.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p><strong>This driver package supports the following adapters:</strong><br />
&nbsp;</p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li>
		<li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li>
		<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li>
		<li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p><strong>This driver package supports the following adapters:</strong><br />
&nbsp;</p>

<ul>
	<li><strong>ConnectX4 Lx</strong>:

	<ul>
		<li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li>
		<li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li>
		<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li>
		<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li>
		<li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX5</strong>:
	<ul>
		<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li>
		<li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li>
		<li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li>
		<li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li>
		<li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li>
		<li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li>
		<li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6</strong>:
	<ul>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li>
		<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li>
		<li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Dx</strong>:
	<ul>
		<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li>
		<li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX6 Lx</strong>:
	<ul>
		<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li>
		<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX7</strong>:
	<ul>
		<li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li>
		<li>HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B22)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter&nbsp;(P45641-B23)</li>
		<li>HPE InfiniBand NDR/Ethernet 400Gb 1-port QSFP112 PCIe5 x16 MCX715105AS-WEAT Adapter (S5R60A)</li>
		<li>HPE InfiniBand NDR 1-port OSFP PCIe5 x16 MCX75310AAS-NEAT Adapter (P45641-B21)</li>
		<li>HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter (P45642-B21)<br />
		&nbsp;</li>
	</ul>
	</li>
	<li><strong>ConnectX8</strong>:
	<ul>
		<li>HPE InfiniBand XDR400/Ethernet 400GbE 2-port QSFP112 PCIe6 x16 HHHL CX8 Crypto Adapter (P79115-H21)</li>
		<li>HPE InfiniBand XDR/Ethernet 2x400GbE 1-port OSFP PCIe6 x16 HHHL CX8 Crypto Adapter (P79114-H21)</li>
	</ul>
	</li>
</ul>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0237</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1023</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0073</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0086</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0085</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1021</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0053</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C9</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0052</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0246</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0346</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0117</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0042</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0102</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0047</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">1015</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0256</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">1017</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0282</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AB</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0068</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0347</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0345</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0348</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0069</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02AF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101B</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0074</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15B3</supported_device_data>
                <supported_device_data name="dev">101D</supported_device_data>
                <supported_device_data name="subven">15B3</supported_device_data>
                <supported_device_data name="subdev">0040</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="mlnx-ofa_kernel" guid="20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-mlnx-ofa_kernel" guid="20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="2043280" date_modified="2026-09-10T12:01:14" md5sum="f84c402ebf052c76e1419c6375fc48d5" sha1sum="1740569f471134c462ab83ec9dc5fb3442d4c141" sha256sum="aaf007fd929ad56600bec9ed51b4786f2af0e8f8511c79db983862445fd83fa0" sha512sum="f0f985a0a93443f262825de5c70917902343264a4e99187e2cf5b729003927d508a76d40ae9e9875c2d85923690e1d473f0f74713ed22968b8a68947b652d7a7" version="26.04" release="OFED.26.04.0.8.6.1.rhel10u2">
            <name>mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./bin/mlnx_conf_mgr.sh</file>
              <file>./bin/mlnx_interface_mgr.sh</file>
              <file>./etc/infiniband</file>
              <file>./etc/infiniband/info</file>
              <file>./etc/infiniband/mlx5.conf</file>
              <file>./etc/infiniband/openib.conf</file>
              <file>./etc/init.d/openibd</file>
              <file>./etc/libibverbs.d</file>
              <file>./etc/libibverbs.d/mlx5.driver</file>
              <file>./etc/mellanox/hugepages.d</file>
              <file>./etc/modprobe.d/ib_ipoib.conf</file>
              <file>./etc/modprobe.d/mlnx-bf.conf</file>
              <file>./etc/modprobe.d/mlnx.conf</file>
              <file>./etc/rdma</file>
              <file>./etc/rdma/mlx4.conf</file>
              <file>./etc/rdma/modules</file>
              <file>./etc/rdma/modules/rdma.conf</file>
              <file>./etc/systemd/system/mlnx_interface_mgr@.service</file>
              <file>./lib/udev/auxdev-sf-netdev-rename</file>
              <file>./lib/udev/mlnx_bf_udev</file>
              <file>./lib/udev/rules.d/83-mlnx-sf-name.rules</file>
              <file>./lib/udev/rules.d/90-ib.rules</file>
              <file>./lib/udev/sf-rep-netdev-rename</file>
              <file>./sbin/doca-hugepages</file>
              <file>./sbin/mlnx-sf</file>
              <file>./sbin/mlnx_bf_configure</file>
              <file>./sbin/sysctl_perf_tuning</file>
              <file>./usr/bin/ib_atomic_bw</file>
              <file>./usr/bin/ib_atomic_lat</file>
              <file>./usr/bin/ib_read_bw</file>
              <file>./usr/bin/ib_read_lat</file>
              <file>./usr/bin/ib_send_bw</file>
              <file>./usr/bin/ib_send_lat</file>
              <file>./usr/bin/ib_write_bw</file>
              <file>./usr/bin/ib_write_lat</file>
              <file>./usr/bin/mlnx_dump_parser</file>
              <file>./usr/bin/mlnx_perf</file>
              <file>./usr/bin/mlnx_qos</file>
              <file>./usr/bin/mlx_fs_dump</file>
              <file>./usr/bin/ofed_info</file>
              <file>./usr/bin/ofed_rpm_info</file>
              <file>./usr/bin/raw_ethernet_burst_lat</file>
              <file>./usr/bin/raw_ethernet_bw</file>
              <file>./usr/bin/raw_ethernet_fs_rate</file>
              <file>./usr/bin/raw_ethernet_lat</file>
              <file>./usr/bin/run_perftest_loopback</file>
              <file>./usr/bin/run_perftest_multi_devices</file>
              <file>./usr/bin/tc_wrap.py</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/02</file>
              <file>./usr/lib/.build-id/02/e44353fa850ffd9aa7bb85810373e293fb4e7f</file>
              <file>./usr/lib/.build-id/12</file>
              <file>./usr/lib/.build-id/12/06539ee0904cf829de0309f963cca7d87987e2</file>
              <file>./usr/lib/.build-id/18</file>
              <file>./usr/lib/.build-id/18/69a48c0f71c97ea9549a621a335b65695e853e</file>
              <file>./usr/lib/.build-id/1a</file>
              <file>./usr/lib/.build-id/1a/2e82d2b820a1a913fd5d95ce5761e2fb3e4176</file>
              <file>./usr/lib/.build-id/1c</file>
              <file>./usr/lib/.build-id/1c/35ea925090feeabe0e2a5d163f9fe655b04bff</file>
              <file>./usr/lib/.build-id/2c</file>
              <file>./usr/lib/.build-id/2c/440f5567574df7af8855587bc46b58689a074f</file>
              <file>./usr/lib/.build-id/2c/966d6358b5acecc83d9890c87d24c2af1b634d</file>
              <file>./usr/lib/.build-id/5e</file>
              <file>./usr/lib/.build-id/5e/385d753f92aef1a637ec7878741b42d0080d58</file>
              <file>./usr/lib/.build-id/80</file>
              <file>./usr/lib/.build-id/80/da383987f7cc582a9fcb9fe23434464f856d70</file>
              <file>./usr/lib/.build-id/9d</file>
              <file>./usr/lib/.build-id/9d/4e8f94e5990b582d39daafc25c0db54042cc23</file>
              <file>./usr/lib/.build-id/a1</file>
              <file>./usr/lib/.build-id/a1/5e99478d4c4c043de8f4aeac9dfc819531fd88</file>
              <file>./usr/lib/.build-id/a7</file>
              <file>./usr/lib/.build-id/a7/b0c1ae3cfa518477a57da1c88a73f6a4b23e8c</file>
              <file>./usr/lib/.build-id/b0</file>
              <file>./usr/lib/.build-id/b0/22acac57daafbbfcd5b01b060812511e16904c</file>
              <file>./usr/lib/.build-id/b9</file>
              <file>./usr/lib/.build-id/b9/80b11215e601a3e8f1b6db28731435ac013754</file>
              <file>./usr/lib/.build-id/bc</file>
              <file>./usr/lib/.build-id/bc/b44092db5ea572f5267751014c44525dccdc82</file>
              <file>./usr/lib/.build-id/ca</file>
              <file>./usr/lib/.build-id/ca/6d55c7d5898beb5eab4d6491aeeb3a9b0ff501</file>
              <file>./usr/lib/.build-id/d9</file>
              <file>./usr/lib/.build-id/d9/17c74cf52fadfb67b2eed0c095eeefb92fa17b</file>
              <file>./usr/lib/.build-id/dc</file>
              <file>./usr/lib/.build-id/dc/54705c1e468f44ffef135c4e81e43c795a0b57</file>
              <file>./usr/lib/.build-id/e1</file>
              <file>./usr/lib/.build-id/e1/c7c2b1ba487b6299289ada024edc44132b730b</file>
              <file>./usr/lib/.build-id/ed</file>
              <file>./usr/lib/.build-id/ed/d9abe05bf048dc95e705d1cede5b6e63d0299f</file>
              <file>./usr/lib/.build-id/f2</file>
              <file>./usr/lib/.build-id/f2/ad50a9a16131c71b4751c781ee1b9baf220d83</file>
              <file>./usr/lib/.build-id/f6</file>
              <file>./usr/lib/.build-id/f6/5def2aa440070a9c216922fce9fcb2da27d652</file>
              <file>./usr/lib/dracut</file>
              <file>./usr/lib/dracut/modules.d</file>
              <file>./usr/lib/dracut/modules.d/50rdma</file>
              <file>./usr/lib/modprobe.d</file>
              <file>./usr/lib/modprobe.d/libmlx4.conf</file>
              <file>./usr/lib/systemd/system/openibd.service</file>
              <file>./usr/lib/systemd/system/rdma-ndd.service</file>
              <file>./usr/lib/udev/rdma_rename</file>
              <file>./usr/lib/udev/rules.d</file>
              <file>./usr/lib/udev/rules.d/60-rdma-ndd.rules</file>
              <file>./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules</file>
              <file>./usr/lib/udev/rules.d/75-rdma-description.rules</file>
              <file>./usr/lib/udev/rules.d/90-rdma-umad.rules</file>
              <file>./usr/lib64/libefa.so.1</file>
              <file>./usr/lib64/libefa.so.1.4.63.0</file>
              <file>./usr/lib64/libibumad.so.3</file>
              <file>./usr/lib64/libibumad.so.3.4.63.0</file>
              <file>./usr/lib64/libibverbs</file>
              <file>./usr/lib64/libibverbs.so.1</file>
              <file>./usr/lib64/libibverbs.so.1.16.63.0</file>
              <file>./usr/lib64/libibverbs/libmlx5-rdmav59.so</file>
              <file>./usr/lib64/libmlx4.so.1</file>
              <file>./usr/lib64/libmlx4.so.1.0.63.0</file>
              <file>./usr/lib64/libmlx5.so.1</file>
              <file>./usr/lib64/libmlx5.so.1.27.63.0</file>
              <file>./usr/lib64/libperftest_kernels.so</file>
              <file>./usr/lib64/librdmacm.so.1</file>
              <file>./usr/lib64/librdmacm.so.1.4.63.0</file>
              <file>./usr/lib64/rsocket</file>
              <file>./usr/lib64/rsocket/librspreload.so</file>
              <file>./usr/lib64/rsocket/librspreload.so.1</file>
              <file>./usr/lib64/rsocket/librspreload.so.1.0.0</file>
              <file>./usr/libexec/mlx4-setup.sh</file>
              <file>./usr/sbin/cma_roce_mode</file>
              <file>./usr/sbin/cma_roce_tos</file>
              <file>./usr/sbin/common_irq_affinity.sh</file>
              <file>./usr/sbin/compat_gid_gen</file>
              <file>./usr/sbin/ib2ib_setup</file>
              <file>./usr/sbin/ibdev2netdev</file>
              <file>./usr/sbin/mlnx_affinity</file>
              <file>./usr/sbin/mlnx_tune</file>
              <file>./usr/sbin/mlnxofedctl</file>
              <file>./usr/sbin/ofed_uninstall.sh</file>
              <file>./usr/sbin/rdma-ndd</file>
              <file>./usr/sbin/rdma_topo</file>
              <file>./usr/sbin/set_irq_affinity.sh</file>
              <file>./usr/sbin/set_irq_affinity_bynode.sh</file>
              <file>./usr/sbin/set_irq_affinity_cpulist.sh</file>
              <file>./usr/sbin/setup_mr_cache.sh</file>
              <file>./usr/sbin/show_counters</file>
              <file>./usr/sbin/show_gids</file>
              <file>./usr/sbin/show_irq_affinity.sh</file>
              <file>./usr/sbin/show_irq_affinity_hints.sh</file>
              <file>./usr/sbin/sysinfo-snapshot.py</file>
              <file>./usr/sbin/vendor_post_uninstall.sh</file>
              <file>./usr/sbin/vendor_pre_uninstall.sh</file>
              <file>./usr/share/doc/libibverbs</file>
              <file>./usr/share/doc/libibverbs/libibverbs.md</file>
              <file>./usr/share/doc/librdmacm</file>
              <file>./usr/share/doc/librdmacm/librdmacm.md</file>
              <file>./usr/share/doc/mlnx-ofa_kernel</file>
              <file>./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules</file>
              <file>./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh</file>
              <file>./usr/share/doc/mlnx-tools</file>
              <file>./usr/share/doc/mlnx-tools/ib2ib_setup.txt</file>
              <file>./usr/share/doc/perftest</file>
              <file>./usr/share/doc/perftest/COPYING</file>
              <file>./usr/share/doc/perftest/README</file>
              <file>./usr/share/doc/perftest/runme</file>
              <file>./usr/share/doc/rdma-core</file>
              <file>./usr/share/doc/rdma-core/70-persistent-ipoib.rules</file>
              <file>./usr/share/doc/rdma-core/README.md</file>
              <file>./usr/share/doc/rdma-core/tag_matching.md</file>
              <file>./usr/share/doc/rdma-core/udev.md</file>
              <file>./usr/share/licenses/mlnx-tools</file>
              <file>./usr/share/licenses/mlnx-tools/LICENSE</file>
              <file>./usr/share/licenses/rdma-core</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_FB</file>
              <file>./usr/share/licenses/rdma-core/COPYING.BSD_MIT</file>
              <file>./usr/share/licenses/rdma-core/COPYING.GPL2</file>
              <file>./usr/share/licenses/rdma-core/COPYING.md</file>
              <file>./usr/share/man/man1/ib_atomic_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_atomic_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_read_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_read_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_send_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_send_lat.1.gz</file>
              <file>./usr/share/man/man1/ib_write_bw.1.gz</file>
              <file>./usr/share/man/man1/ib_write_lat.1.gz</file>
              <file>./usr/share/man/man1/perftest.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_burst_lat.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_bw.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_fs_rate.1.gz</file>
              <file>./usr/share/man/man1/raw_ethernet_lat.1.gz</file>
              <file>./usr/share/man/man7/rsocket.7.gz</file>
              <file>./usr/share/man/man8/ib2ib_setup.8.gz</file>
              <file>./usr/share/man/man8/mlnxofedctl.8.gz</file>
              <file>./usr/share/man/man8/rdma-ndd.8.gz</file>
              <file>./usr/share/mlnx-tools/python/dcbnetlink.py</file>
              <file>./usr/share/mlnx-tools/python/netlink.py</file>
              <file>./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh</file>
              <file>./usr/share/mlnx_ofed/mlnx_drv_ctl</file>
              <file>./usr/share/mlnx_ofed/mod_load_funcs</file>
              <file>./usr/share/smartupdate/mlnx-ofa_kernel/component.xml</file>
            </file_list>
          </file>
          <file size="2MB" bytes="2832500" date_modified="2026-09-10T11:56:08" md5sum="fcefaadfecc566b6fcac4f456bdd8f08" sha1sum="ae78e0ad4a3cea03a8180d3ef31126fedf6792fb" sha256sum="bed6324c9eb13a8fb2ace61e968764a4e4c7d9d5068fde86b88ce45ef2236f80" sha512sum="1f0300dd4ef52eaa422c695557477dbdd4eda091b08df678af1dd58c474508d37853e2d70e6fe6b2b5da2c48467ebbb59de6fe8bd68d3301dfb966717d48c095" version="26.04" release="OFED.26.04.0.8.6.1.1.rhel10u2">
            <name>kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf</file>
              <file>./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/compat</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs/cifs</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/06</file>
              <file>./usr/lib/.build-id/06/6454e03ae0514fac741df14a4bc4ffb2801147</file>
              <file>./usr/lib/.build-id/0a</file>
              <file>./usr/lib/.build-id/0a/4a94c3b4de3e997a69011820b5c9d4053f2ad7</file>
              <file>./usr/lib/.build-id/15</file>
              <file>./usr/lib/.build-id/15/d703d62cbbd4e2820b7e43d72930efcd85f7a9</file>
              <file>./usr/lib/.build-id/1f</file>
              <file>./usr/lib/.build-id/1f/5cd29fd23cd6c6726af2ac735157502ba6f7a2</file>
              <file>./usr/lib/.build-id/20</file>
              <file>./usr/lib/.build-id/20/a544f2c62cd305a272d07cb12a4058cb17cc9c</file>
              <file>./usr/lib/.build-id/26</file>
              <file>./usr/lib/.build-id/26/938f6bd95026be5c2d482abb94692d566f95b0</file>
              <file>./usr/lib/.build-id/2a</file>
              <file>./usr/lib/.build-id/2a/16596591ea13c9b4e4bd263fa37ea58ecb3429</file>
              <file>./usr/lib/.build-id/32</file>
              <file>./usr/lib/.build-id/32/28303957e913e9f7e4da8d6f7763795ee92879</file>
              <file>./usr/lib/.build-id/37</file>
              <file>./usr/lib/.build-id/37/5d097b48092f435aa9025eff9b93b6888c2442</file>
              <file>./usr/lib/.build-id/3a</file>
              <file>./usr/lib/.build-id/3a/90c7a9036bf9a0f77a385887b58adb6915596f</file>
              <file>./usr/lib/.build-id/3b</file>
              <file>./usr/lib/.build-id/3b/7d18a172fc48ef6377ff742dccb72472ffb807</file>
              <file>./usr/lib/.build-id/4b</file>
              <file>./usr/lib/.build-id/4b/acbaa34ce8b6c5b3664441c7d5bd23a1943f93</file>
              <file>./usr/lib/.build-id/4e</file>
              <file>./usr/lib/.build-id/4e/595375cf68fd142090882011b0090ad18010b5</file>
              <file>./usr/lib/.build-id/52</file>
              <file>./usr/lib/.build-id/52/f71b78cd9318a2919c0fa70cb2f94db96cc38c</file>
              <file>./usr/lib/.build-id/55</file>
              <file>./usr/lib/.build-id/55/94b1cf220e46e12288006a08580d2134ad40fe</file>
              <file>./usr/lib/.build-id/5b</file>
              <file>./usr/lib/.build-id/5b/0494c8c0dcf4e87d4f706c94a6f83f614c142b</file>
              <file>./usr/lib/.build-id/5c</file>
              <file>./usr/lib/.build-id/5c/0948744717fbed5b8079ff7fe94319a0838c47</file>
              <file>./usr/lib/.build-id/5f</file>
              <file>./usr/lib/.build-id/5f/b90a986dc064f981678d3f31ab87d39e26df10</file>
              <file>./usr/lib/.build-id/62</file>
              <file>./usr/lib/.build-id/62/6aba4b3d67b519ab96c0f79146102263479590</file>
              <file>./usr/lib/.build-id/62/fb5f29c801d3ffd564a90b33cacf31b59c0f7c</file>
              <file>./usr/lib/.build-id/64</file>
              <file>./usr/lib/.build-id/64/50460cee9b33f4cf6fdce5469c7abb25a458cb</file>
              <file>./usr/lib/.build-id/6a</file>
              <file>./usr/lib/.build-id/6a/d3be36ccaabe4f1774914f78834d735579e078</file>
              <file>./usr/lib/.build-id/6f</file>
              <file>./usr/lib/.build-id/6f/b734af9b6bc3b4a6a4bfd4d7e1492b3fa6a926</file>
              <file>./usr/lib/.build-id/7f</file>
              <file>./usr/lib/.build-id/7f/82a1ac22a03daa4f14fcf90c000b2719458ce0</file>
              <file>./usr/lib/.build-id/89</file>
              <file>./usr/lib/.build-id/89/527646a93cc188f927fdb933651b4c13eeb77d</file>
              <file>./usr/lib/.build-id/89/ae8cd102de82b60999ffaaccb85bd347c8b83a</file>
              <file>./usr/lib/.build-id/8b</file>
              <file>./usr/lib/.build-id/8b/403d1fa776f4143538624ebe51e1db0b2f9dba</file>
              <file>./usr/lib/.build-id/9d</file>
              <file>./usr/lib/.build-id/9d/9c783838a14b74c7c3f68dc2b4671f887308bc</file>
              <file>./usr/lib/.build-id/a3</file>
              <file>./usr/lib/.build-id/a3/3907fc72d96e29145fe9f9eb33350c23c67037</file>
              <file>./usr/lib/.build-id/b5</file>
              <file>./usr/lib/.build-id/b5/af6a4c030692aae8b1690e4725cdb8d9c24490</file>
              <file>./usr/lib/.build-id/b7</file>
              <file>./usr/lib/.build-id/b7/c6666999ece56c1ce326d967f6114673a36ab8</file>
              <file>./usr/lib/.build-id/b8</file>
              <file>./usr/lib/.build-id/b8/5382f519888770f5b1efd1c3bc510312026ba7</file>
              <file>./usr/lib/.build-id/bf</file>
              <file>./usr/lib/.build-id/bf/84a68a7573b643407fab6414c1d6d48b1df679</file>
              <file>./usr/lib/.build-id/c9</file>
              <file>./usr/lib/.build-id/c9/9420c21ba9e70a67dac2654174760f46bb145d</file>
              <file>./usr/lib/.build-id/d4</file>
              <file>./usr/lib/.build-id/d4/eb5bf4239f25adbaf27478e6fc68d62700a6e5</file>
              <file>./usr/lib/.build-id/d6</file>
              <file>./usr/lib/.build-id/d6/a14d6fcb691ba51f1829c78e6ffb10fe2d3de0</file>
              <file>./usr/lib/.build-id/e3</file>
              <file>./usr/lib/.build-id/e3/434fcce9679ed5293e96307053af637f5808ac</file>
              <file>./usr/lib/.build-id/e9</file>
              <file>./usr/lib/.build-id/e9/0546c43cd6e740a7efea0c49e5534ee9fe0014</file>
              <file>./usr/lib/.build-id/ef</file>
              <file>./usr/lib/.build-id/ef/34659f71d902658b6c13291e698085e9e041dd</file>
              <file>./usr/lib/.build-id/f8</file>
              <file>./usr/lib/.build-id/f8/25d63578bbde9fa7ed954506fbce2125db61dd</file>
              <file>./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="3a6d4809181347e4a3065dc554aaf159">
      <product_version>
        <id product="3a6d4809181347e4a3065dc554aaf159" version="0783ca374b374ff1bc91c7c19cb76b58" lucid_version="nicfwpkg_intel_e835_xxv4@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="7"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="07" day="01" hour="06" minute="30" second="01"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA4 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA4 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td>
			<td>80018D57</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td>
			<td>80018D57</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>

<p>For more product details, please refer to the latest document in <a href="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html" id="menur20ej" rel="noreferrer noopener" target="_blank" title="https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_XXV4_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_XXVDA4_2p10_MCTP_80018D57.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794281" date_modified="2026-08-18T07:34:00" md5sum="246e939b66d184a1f4d328e2e523c533" sha1sum="187f671fb6e4858fffd6165c2da0612893c837c4" sha256sum="e3e2d7849511a248a0338fad8f93cb304928695f3a9272619172223b744eeb84" sha512sum="0250a29fd603091dded9b38d37e859ddfb2b63d36ab8ecd5e9b9c28b3ebf3c903413ff38c80bb65bb7d6d3cd4a1921f4e049360ac3109acefec1b6ca1189c212">
            <name>HPE_E835_XXVDA4_2p10_MCTP_80018D57.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_XXVDA4_2p10_MCTP_80018D57.fwpkg</url>
            <file_list>
              <file>HPE_E835_XXVDA4_2p10_MCTP_80018D57.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-XXVDA4 adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_XXVDA4_2p10_MCTP_80018D57.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124a80860002</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="47f4a7dc24da4da4908a6e9a73c6ed6b">
      <product_version>
        <id product="47f4a7dc24da4da4908a6e9a73c6ed6b" version="7d43f3377bb24e049d969ddd1e03b67c" lucid_version="nicfwpkg_intel_e835_xxv2@2.10__fwpkg-generic_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28  Adapter</name_xlate>
          <name_xlate lang="en">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28  Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28  Adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Intel Firmware Package For E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28  Adapter</alt_name_xlate>
        </alt_name>
        <version value="2.10" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="28" hour="08" minute="41" second="26"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA2 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Intel E835-XXVDA2 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href="https://support.hpe.com/">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href="https://support.hpe.com/">https://support.hpe.com</a>)</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
	<li>
	<p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter for HPE</td>
			<td>80018D0A</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>

<table border="1">
	<thead>
		<tr>
			<th>NIC</th>
			<th>EEPROM ID</th>
			<th>OROM Version</th>
			<th>NVM Version</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Intel E835-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter for HPE</td>
			<td>80018D0A</td>
			<td>1.4002.0</td>
			<td>2.10</td>
		</tr>
	</tbody>
</table>

<p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 2.10</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="INTEL_E835_XXV2_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_E835_XXVDA2_2p10_MCTP_80018D0A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="16MB" bytes="16794281" date_modified="2026-08-18T07:07:44" md5sum="cf182e67a1c4342e84f7fb654138fa73" sha1sum="4ce6f8f95139064d2fe99ace58cc76a25da4c74a" sha256sum="93afc3debaacadf6eca1be12f2c6036921aaf19ed0e983784243ee172bb18f6a" sha512sum="0d03ee2753cf683f55071a64e7d07fb074ce1df8e5f3b269f9d36762ed183c7e422db6cfd4e5204551ef81a31ce2860d3e03d2ace4956792650a4ebb1d2bc171">
            <name>HPE_E835_XXVDA2_2p10_MCTP_80018D0A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_E835_XXVDA2_2p10_MCTP_80018D0A.fwpkg</url>
            <file_list>
              <file>HPE_E835_XXVDA2_2p10_MCTP_80018D0A.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Intel E835-XXVDA2 adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_E835_XXVDA2_2p10_MCTP_80018D0A.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-8086-124a80860008</Target>
              <Version>2.10</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="da9ff49af6c74b6d969bca700eb095c0">
      <product_version>
        <id product="da9ff49af6c74b6d969bca700eb095c0" version="3b117e96360a4e04af1266d67a95d5d4" lucid_version="ixgbe.rhel10@6.4.4-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="2"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbeドライバーfor Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbeドライバーfor Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="6.4.4-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="42"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、Red Hat Enterprise Linux 10で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 10.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル (標準カーネル) 用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル (errataカーネルなど) 上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ (例：<ドライバー>.src.rpm) をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-ixgbe" guid="20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-ixgbe" guid="20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="444KB" bytes="455049" date_modified="2026-09-02T09:29:09" md5sum="acd114dbfbe517aa1456d5c94daaff50" sha1sum="36782112ee027c0f6cc12bdad6ade8d435ca93f1" sha256sum="548dd46b41c634008d3ea5c6d192f07ddf6c2d74841e4e014aa792276bea6add" sha512sum="847e132329bebe5ffb4989587c2330d0bf1f2609dce3be19ffce21990f71f58965d7ae57da71a1f60a705e2f01e9d3f89e5af74421bd244797d2022908e40d09" version="6.4.4" release="1.rhel10u1">
            <name>kmod-ixgbe-6.4.4-1.rhel10u1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ixgbe-6.4.4-1.rhel10u1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ixgbe.conf</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ixgbe/ixgbe.ko</file>
              <file>./usr/share/doc/kmod-ixgbe</file>
              <file>./usr/share/doc/kmod-ixgbe/COPYING</file>
              <file>./usr/share/doc/kmod-ixgbe/README</file>
              <file>./usr/share/doc/kmod-ixgbe/pci.updates</file>
              <file>./usr/share/man/man7/ixgbe.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ixgbe/component.xml</file>
            </file_list>
          </file>
          <file size="443KB" bytes="454401" date_modified="2026-09-02T09:34:14" md5sum="ae95d45988bc13f842451361674ea9b7" sha1sum="a4d0e302d7755e0c6436162f80300d3d54f6918b" sha256sum="e3a47eca108aaa2fb1742432f040db2b7c355922f5f05a92d994fc9e5f2efafa" sha512sum="87a0ad505fbf7019ac6b4685b5c193be800637eb46df3f90cae73d929efc300ad70a23bb0fff42fe3921d7c1fc423a612ab106fdb8a417a4ded4958fbd2e540c" version="6.4.4" release="1.rhel10u2">
            <name>kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/kmod-ixgbe.conf</file>
              <file>./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ixgbe/ixgbe.ko</file>
              <file>./usr/share/doc/kmod-ixgbe</file>
              <file>./usr/share/doc/kmod-ixgbe/COPYING</file>
              <file>./usr/share/doc/kmod-ixgbe/README</file>
              <file>./usr/share/doc/kmod-ixgbe/pci.updates</file>
              <file>./usr/share/man/man7/ixgbe.7.gz</file>
              <file>./usr/share/smartupdate/kmod-ixgbe/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="cb50e456662942af91a87d5e0217de4b">
      <product_version>
        <id product="cb50e456662942af91a87d5e0217de4b" version="9528e4d1fe784c33bba6b88caf7172a9" lucid_version="intel_lkv.w2k22@1.8.54.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="2"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Intel ixwドライバーfor Windows Server 2022</name_xlate>
          <name_xlate lang="en">Intel ixw Driver for Windows Server 2022</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel ixwドライバーfor Windows Server 2022</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ixw Driver for Windows Server 2022</alt_name_xlate>
        </alt_name>
        <version value="1.8.54.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems/>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="34"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel ixw 10 Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the driver for Intel ixw 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="400"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ixw.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecce65d793">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073015.exe</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1217824" date_modified="2026-09-01T09:19:15" md5sum="d358f6d529e00ced59578872d426e4e2" sha1sum="bf6a9af2120bad6abda1ca723c7947136c45efb1" sha256sum="ca4315a70772729568f9a0236c20edf19f5340b78a13b8b02a100d66f2d5c0ad" sha512sum="c17f79e6343d4f5acf978e282525efab1d070d0d45c013bfdeaa6c96b467536f0e2941c7b036928c86152606a1db2fc2bcd3614d25647fc27e4d405f0b6defe0">
            <name>cp073015.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073015.exe</url>
            <file_list>
              <file>cp073015.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>ixw.cat</file>
              <file>ixw.inf</file>
              <file>ixw.sys</file>
              <file>ixwmsg.dll</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="e58df07e11424ebea13ea14cdbc1492d">
      <product_version>
        <id product="e58df07e11424ebea13ea14cdbc1492d" version="0c5d9c9c61cf4276ab2c40b4a8fb9a8f" lucid_version="bnxt_roce.rhel9u8@238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="5"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 8.</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 8.</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 7.</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 7.</alt_name_xlate>
        </alt_name>
        <version value="238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 7.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 7.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9</em>, version 1.10.3-237.1.137.0&nbsp;or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9</em>, version 1.10.3-237.1.137.0&nbsp;or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="libbnxt_re" guid="20a6e8e4-bf33-4c71-a6bf-d9ecff04767d">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>libbnxt_re-238.1.165.0-rhel9u8.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="63KB" bytes="65195" date_modified="2026-09-03T04:11:54" md5sum="e8a7550bbec185013be0fbccc03fe8b6" sha1sum="5329a15a1651c63d78ff2aab413c575d87e7a8c4" sha256sum="c4d75271ce3d22c0b1cc490a602d18ea97929213078fcc875c62213c87889602" sha512sum="23fc138d46224fa64eb6f8e11795b312f8a47b13268d52e74bc26b4c522fd0924665251594a731b9916cba70ef072afc47961bee97afe934987c1888780eaac6" version="238.1.165.0" release="rhel9u8">
            <name>libbnxt_re-238.1.165.0-rhel9u8.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/libbnxt_re-238.1.165.0-rhel9u8.x86_64.rpm</url>
            <file_list>
              <file>./etc/libibverbs.d/bnxt_re.driver</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/ae</file>
              <file>./usr/lib/.build-id/ae/a27530fba114a5925e9d342924da727701a74a</file>
              <file>./usr/lib64/libbnxt_re-238.1.165.0.so</file>
              <file>./usr/lib64/libbnxt_re-rdmav59.so</file>
              <file>./usr/lib64/libbnxt_re.so</file>
              <file>./usr/lib64/pkgconfig/libbnxt_re.pc</file>
              <file>./usr/share/smartupdate/libbnxt_re/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="29a000381a7c4ec8a72063a155821a0a">
      <product_version>
        <id product="29a000381a7c4ec8a72063a155821a0a" version="b3873fd253224088a232ecd921ca6590" lucid_version="ice.sles15@2.6.6-1(B)__pubsw-linux_en"/>
        <different>new</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Intel iceドライバーfor SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">Intel ice Drivers for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel iceドライバーfor SUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ice Drivers for SUSE Linux Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="2.6.6-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="13"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 15で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0006</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">159B</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1592</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1593</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">000C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">579E</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">12D3</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0007</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0001</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124a</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0008</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0004</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">124A</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0002</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1249</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0005</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ice-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="ice-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="23MB" bytes="24860750" date_modified="2026-09-02T08:47:57" md5sum="278336cfc6c929e2649dd65c89820ec8" sha1sum="6b07bb965a209d6dd6d3629bce3d5b19707c763d" sha256sum="30f4a1eaae98c65687cad70082e98a0a5d38912897a28a965dee1eea4340fb76" sha512sum="e6ed2e6d847c19bdc65636434a90b623654fb173ae2fa4f8d7e6127087640b1bffb32ad763d6c10f6b99de91a2cc39240c425e2369fea58e879954ad3ac3f146" version="2.6.6_k6.4.0_150600.21" release="1.sles15sp6">
            <name>ice-kmp-default-2.6.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ice-kmp-default-2.6.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/ice.conf</file>
              <file>./etc/dracut.conf.d/ice-oob.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/ice</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/ice/ice.ko</file>
              <file>./usr/share/doc/packages/ice</file>
              <file>./usr/share/doc/packages/ice/COPYING</file>
              <file>./usr/share/doc/packages/ice/README</file>
              <file>./usr/share/doc/packages/ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/ice-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="1MB" bytes="1155030" date_modified="2026-09-02T08:52:17" md5sum="8081d27d194405b2bd480520b5c42b42" sha1sum="d13051f9d33b5338b19d48d80ccce5acb173f388" sha256sum="8e801db5029a349aad1afd9f4fca92a0b64af1f642a4163165c6ef66ff1447a8" sha512sum="ae04a4200914ef20041b2760c310dc2636aab1280cf9734414be1a079b9c1c282d5cd6069951cbf418c796dab69585b7a614d674456f069fcfd989dcdd3ab85c" version="2.6.6_k6.4.0_150700.51" release="1.sles15sp7">
            <name>ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/ice.conf</file>
              <file>./etc/dracut.conf.d/ice-oob.conf</file>
              <file>./lib/firmware/updates/intel/ice/ddp/LICENSE</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg</file>
              <file>./lib/firmware/updates/intel/ice/ddp/ice.pkg</file>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/ice</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/ice/ice.ko</file>
              <file>./usr/share/doc/packages/ice</file>
              <file>./usr/share/doc/packages/ice/COPYING</file>
              <file>./usr/share/doc/packages/ice/README</file>
              <file>./usr/share/doc/packages/ice/pci.updates</file>
              <file>./usr/share/man/man7/ice.7.gz</file>
              <file>./usr/share/smartupdate/ice-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="58259b45dec7469580dfbddb76171768">
      <product_version>
        <id product="58259b45dec7469580dfbddb76171768" version="fef8f994b9ac4588ae27e311a30a1f8e" lucid_version="ixgbevf.sles15@5.3.36-1(B)__pubsw-linux_en"/>
        <different>changed</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="5.3.36-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="54"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li>
</ul>

<p style="margin-left:40px">* 以前のWebリリースixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />
    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf-kmp-default）から（igb-ixgbevf-default）に変更されました。この変更を（ixgbevf-kmp-default）から（<strong>hp</strong>-ixgbevf-kmp-default）に戻しました。<br />
    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />
* <strong>hp</strong>-ixgbevf-kmp-defaultとixgbevf-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />
  混乱を避けるため、すでにixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbevf-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li>
</ul>

<p style="margin-left:40px">* The previous web release ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />
&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf-kmp-default) to (igb-ixgbevf-default). Now we revert this change from (ixgbevf-kmp-default) to (<strong>hp</strong>-ixgbevf-kmp-default).<br />
&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />
* <strong>hp</strong>-ixgbevf-kmp-default and ixgbevf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />
&nbsp; To avoid confusion, if you already download and install ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbevf-kmp-default and then install the updated RPM.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="hp-ixgbevf-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="hp-ixgbevf-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1518584" date_modified="2026-09-02T10:09:11" md5sum="942b6279bc9afcbdde3846c98a44088c" sha1sum="692b6eb6b0235f150e545687cd8afcbf2dad6e17" sha256sum="bcacf925453aca70ea9d97c03212aa50a3268e5d5d51f3eee47122b7f1789812" sha512sum="a97a60aeb5d7da2f3b09092c6d477d1b255d7c291095246670e7e3cf7bcf10e97b90c0e4c89006f2ba5eb2f761298d69481e0328f3f2c9cadf9bf7c3d8f8d464" version="5.3.36_k6.4.0_150600.21" release="1.sles15sp6">
            <name>hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbevf.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbevf-oob.conf</file>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf/ixgbevf.ko</file>
              <file>./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="87KB" bytes="89978" date_modified="2026-09-02T10:14:16" md5sum="0eae00d2774dec4b72439dd905648014" sha1sum="cf6c4a2249a9ebf0257cd5ca093b71d44a226423" sha256sum="1e58e6c041b818eb082207c4c4cbcfedfcd0fdbdb51aee28ea63bd49ac419721" sha512sum="6fceb4a51618ee5f1dc24a531bd4c2440418ae71d51baa0dcb334202563c04bdd1deaf0f337a34a1a82ae715792a2651c768f7e1fb9e597346f215f5a9df5d34" version="5.3.36_k6.4.0_150700.51" release="1.sles15sp7">
            <name>hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbevf.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbevf-oob.conf</file>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf/ixgbevf.ko</file>
              <file>./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="332a1cff050e45b999d3c0f17ade482b">
      <product_version>
        <id product="332a1cff050e45b999d3c0f17ade482b" version="37174802f3a942d08fd3871e3c3bd6bb" lucid_version="bnxt_roce.sles15sp7@238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="4"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCEライブラリfor SUSE Linux Enterprise Server 15 SP7</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom NetXtreme-E RoCEライブラリfor SUSE Linux Enterprise Server 15 SP7</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7</alt_name_xlate>
        </alt_name>
        <version value="238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、SUSE Linux Enterprise Server 15 SP7下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP7.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>この製品をインストールする前に、<em>HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15</em>、バージョン1.10.3-237.1.137.0以降をインストールする必要があります。</p>

<p>RoCEライブラリをインストールする前に、ターゲットシステムにlibibverbおよびrdma-coreパッケージをインストールしておく必要があります。まだインストールしていない場合は、オペレーティングシステムのインストールメディアからパッケージを取得できます。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15</em>, version 1.10.3-237.1.137.0 or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh <bnxt_rooce >.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="libbnxt_re" guid="20a6e8e4-bf33-4c71-a6bf-d9ecff04767d">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>libbnxt_re-238.1.165.0-sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="61KB" bytes="62763" date_modified="2026-09-03T04:06:00" md5sum="0cff617fa223d1088277d74a490fbf8c" sha1sum="2c07b96b9da226ffb75206440e18c89d189e3442" sha256sum="09731d08c859095aa28412a50dd8ed2671f8d3032f8c9f83b07b1441c9522e0a" sha512sum="11b194cf6e93ebad687748f345cda7b90c366e53f0eebd5eef3a982fe6e0721f629f3d3f4cfb7dc044df1d6480d2546c7fcc4caa9d4d8666e303666ca4886b5b" version="238.1.165.0" release="sles15sp7">
            <name>libbnxt_re-238.1.165.0-sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/libbnxt_re-238.1.165.0-sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./etc/libibverbs.d/bnxt_re.driver</file>
              <file>./usr/lib64/libbnxt_re-238.1.165.0.so</file>
              <file>./usr/lib64/libbnxt_re-rdmav34.so</file>
              <file>./usr/lib64/libbnxt_re.so</file>
              <file>./usr/lib64/pkgconfig/libbnxt_re.pc</file>
              <file>./usr/share/smartupdate/libbnxt_re/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="cd4b5a9c9ed9405abbc5be7a9f037870">
      <product_version>
        <id product="cd4b5a9c9ed9405abbc5be7a9f037870" version="0da5cd24cd724962aaaa9fd21e02d376" lucid_version="amsd_sles15@5.1.0__pubsw-linux_en"/>
        <different>changed</different>
        <build number="18"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">ams_sles15</alt_name_xlate>
          <alt_name_xlate lang="en">ams_sles15</alt_name_xlate>
        </alt_name>
        <version value="5.1.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="05" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out (iLO 5 and above) Embedded Health and Alerting.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Agentless Management Service (AMSD) provides support for Integrated Lights-Out (iLO 5 and above) Embedded Health and Alerting.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above, service providing SNMP support.</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>
	<p>amsd only supported on HPE Gen10/Gen10 Plus and later Server Generations.</p>
	</li>
	<li>
	<p>amsd provides information to the iLO 5 and above, service providing SNMP support.</p>
	</li>
	<li>
	<p><strong>For HPE servers with iLO 7 and above:</strong><br />
	Ensure that the iLO Virtual NIC(VNIC) feature is enabled. Please refer to the HPE iLO User Guide for VNIC configuration procedure.</p>
	</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p><strong>HPE servers with iLO 7 and above:</strong></p>

<p>On HPE Gen12 servers with iLO7 and above, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />
&nbsp;<br />
Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p>

<p><strong>Installation methods:</strong><br />
&nbsp;<br />
Method 1: Non interactive installation<br />
&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />
&nbsp;&nbsp;<br />
Method 2: Using rpm command<br />
To install the package, type:</p>

<ul>
	<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
</ul>

<p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />
&nbsp;<br />
If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />
&nbsp;<br />
To check whether the package is loaded properly, type:</p>

<ul>
	<li>systemctl status amsd</li>
	<li>systemctl status smad</li>
</ul>

<p>Additional help is available by typing:</p>

<ul>
	<li>man amsd</li>
</ul>

<p><strong>Using amscli to create application account:</strong><br />
&nbsp;<br />
If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p>

<ul>
	<li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;<br />
<strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />
&nbsp;<br />
If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p>

<ul>
	<li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li>
</ul>

<p>&nbsp;</p>

<p><strong>HPE servers with iLO 5 and iLO 6:</strong></p>

<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>

<ul>
	<li>To install the package type:
	<ul style="list-style-type:circle">
		<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>
	</ul>
	</li>
	<li>To check whether the package is loaded properly type:
	<ul style="list-style-type:circle">
		<li>systemctl status amsd</li>
		<li>systemctl status smad</li>
	</ul>
	</li>
	<li>Additional help is available by typing:
	<ul style="list-style-type:circle">
		<li>man amsd</li>
	</ul>
	</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2f317b9d-c9e3-4d76-bff6-b9d0d085a952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">3307</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amsd" guid="20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>amsd-5.1.0-2197.8.sles15.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="11MB" bytes="11649346" date_modified="2026-09-30T09:11:06" md5sum="11f9826fb233b860f0f416f99aa53262" sha1sum="b34bbdba2224207c49ca242bf11eb28eae206aff" sha256sum="252aded8ecc8e45e32550c85b389c55af8f2e719fb5187d897fd8f3c0892a51d" sha512sum="2c05f16b5e471c7a3e2ff879039673664d246e7b23dbab8454bf421cff8c30d5198e03e75238a35f65f27b74f6a4b261e50556c4d5561fc2eae57e11b8cb72d4" version="5.1.0" release="2197.8.sles15">
            <name>amsd-5.1.0-2197.8.sles15.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/amsd-5.1.0-2197.8.sles15.x86_64.rpm</url>
            <file_list>
              <file>./etc/sysconfig/ahslog</file>
              <file>./etc/sysconfig/amsd</file>
              <file>./etc/sysconfig/amsd_rev</file>
              <file>./etc/sysconfig/cpqFca</file>
              <file>./etc/sysconfig/cpqFca_rev</file>
              <file>./etc/sysconfig/cpqIde</file>
              <file>./etc/sysconfig/cpqIde_rev</file>
              <file>./etc/sysconfig/cpqScsi</file>
              <file>./etc/sysconfig/cpqScsi_rev</file>
              <file>./etc/sysconfig/cpqiScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi</file>
              <file>./etc/sysconfig/mr_cpqScsi_rev</file>
              <file>./etc/sysconfig/smad</file>
              <file>./etc/sysconfig/smad_rev</file>
              <file>./opt/amsd</file>
              <file>./opt/amsd/amsd.license</file>
              <file>./sbin/ahslog</file>
              <file>./sbin/amscli</file>
              <file>./sbin/cpqiScsi</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/1c</file>
              <file>./usr/lib/.build-id/1c/553f42634c7caf14a39c3deba409e1ceaa2ae6</file>
              <file>./usr/lib/.build-id/1c/553f42634c7caf14a39c3deba409e1ceaa2ae6.1</file>
              <file>./usr/lib/.build-id/25</file>
              <file>./usr/lib/.build-id/25/f6ebf16795cb2c9e0cfb498222d6b2c872e985</file>
              <file>./usr/lib/.build-id/25/f6ebf16795cb2c9e0cfb498222d6b2c872e985.1</file>
              <file>./usr/lib/.build-id/28</file>
              <file>./usr/lib/.build-id/28/87bd7d2760429c1ced4e9fa2dfa9a010cd3d6b</file>
              <file>./usr/lib/.build-id/3c</file>
              <file>./usr/lib/.build-id/3c/cf989a36f5488be20627d26f8c18e0f46ebfcd</file>
              <file>./usr/lib/.build-id/3c/cf989a36f5488be20627d26f8c18e0f46ebfcd.1</file>
              <file>./usr/lib/.build-id/8b</file>
              <file>./usr/lib/.build-id/8b/5d9797a0aabcc819255f60768c2970279f816c</file>
              <file>./usr/lib/.build-id/8d</file>
              <file>./usr/lib/.build-id/8d/a7a5010d5ae652c513c455e05ccbc659d14396</file>
              <file>./usr/lib/.build-id/c8</file>
              <file>./usr/lib/.build-id/c8/b1726dfd5ddd795d0f0806e1d28e226966ac31</file>
              <file>./usr/lib/.build-id/c8/b1726dfd5ddd795d0f0806e1d28e226966ac31.1</file>
              <file>./usr/lib/.build-id/d0</file>
              <file>./usr/lib/.build-id/d0/d299c5f060d61d44c3725c475a299a5bf0b4b9</file>
              <file>./usr/lib/.build-id/d0/d299c5f060d61d44c3725c475a299a5bf0b4b9.1</file>
              <file>./usr/lib/.build-id/d3</file>
              <file>./usr/lib/.build-id/d3/f4f4e79fb0baee75426a81e5f8334842aa4aef</file>
              <file>./usr/lib/.build-id/d3/f4f4e79fb0baee75426a81e5f8334842aa4aef.1</file>
              <file>./usr/lib/systemd/system/ahslog.service</file>
              <file>./usr/lib/systemd/system/amsd.service</file>
              <file>./usr/lib/systemd/system/amsd_rev.service</file>
              <file>./usr/lib/systemd/system/cpqFca.service</file>
              <file>./usr/lib/systemd/system/cpqFca_rev.service</file>
              <file>./usr/lib/systemd/system/cpqIde.service</file>
              <file>./usr/lib/systemd/system/cpqIde_rev.service</file>
              <file>./usr/lib/systemd/system/cpqScsi.service</file>
              <file>./usr/lib/systemd/system/cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/cpqiScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi.service</file>
              <file>./usr/lib/systemd/system/mr_cpqScsi_rev.service</file>
              <file>./usr/lib/systemd/system/smad.service</file>
              <file>./usr/lib/systemd/system/smad_rev.service</file>
              <file>./usr/lib/udev/rules.d/81-cpqFca.rules</file>
              <file>./usr/lib/udev/rules.d/81-cpqiScsi.rules</file>
              <file>./usr/share/man/man8/ahslog.8.gz</file>
              <file>./usr/share/man/man8/amsd.8.gz</file>
              <file>./usr/share/man/man8/cpqFca.8.gz</file>
              <file>./usr/share/man/man8/cpqIde.8.gz</file>
              <file>./usr/share/man/man8/cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/cpqiScsi.8.gz</file>
              <file>./usr/share/man/man8/mr_cpqScsi.8.gz</file>
              <file>./usr/share/man/man8/smad.8.gz</file>
              <file>./usr/share/smartupdate/amsd/component.xml</file>
              <file>./sbin/amsd</file>
              <file>./sbin/amsd_rev</file>
              <file>./sbin/cpqFca</file>
              <file>./sbin/cpqFca_rev</file>
              <file>./sbin/cpqIde</file>
              <file>./sbin/cpqIde_rev</file>
              <file>./sbin/cpqScsi</file>
              <file>./sbin/cpqScsi_rev</file>
              <file>./sbin/mr_cpqScsi</file>
              <file>./sbin/mr_cpqScsi_rev</file>
              <file>./sbin/smad</file>
              <file>./sbin/smad_rev</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="028906580c704fe8918636570e36ae0e">
      <product_version>
        <id product="028906580c704fe8918636570e36ae0e" version="8e2b9b5d240e4353a0c68b5b9e7e1d3b" lucid_version="FanBoardManager1_FWPKG@1.00__fwpkg-generic_en"/>
        <different>new</different>
        <build number="14"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Firmware Package - FBM1 FanBoard MCU for Gen13 servers usage</name_xlate>
          <name_xlate lang="en">Firmware Package - FBM1 FanBoard MCU for Gen13 servers usage</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Firmware Package - FBM1 FanBoard MCU for Gen13 servers usage</alt_name_xlate>
          <alt_name_xlate lang="en">Firmware Package - FBM1 FanBoard MCU for Gen13 servers usage</alt_name_xlate>
        </alt_name>
        <version value="1.00" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11701">
            <operating_system_xlate>Ubuntu 26.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900027">
          <category_xlate lang="ja">ファームウェア - システム</category_xlate>
          <category_xlate lang="en">Firmware - System</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the binaries for upgrading Fan Board Manager 1.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the binaries for upgrading Fan Board Manager 1.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>For Gen13 servers iLO 8 version 1.05 or later is required</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>For Gen13 servers iLO 8 version 1.05 or later is required</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>&nbsp; &nbsp; localhost OS example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>&nbsp; &nbsp; remote example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>&nbsp; &nbsp; localhost OS example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>&nbsp; &nbsp; remote example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="2" sr="OEM" name="VMware ESX 9.2"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="ubuntu2604" major="26" minor="04" sr="OEM" name="Ubuntu 26.04 LTS"/>
            <supported_operating_system platform="Linux" major="10" minor="0" sr="OEM" name="Oracle Linux 10"/>
          </supported_operating_systems>
          <supported_devices/>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="FBM1" guid="">
              <sw_key_expectedpath>firmware:riser:mcu</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>FanBoardV01.00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="70KB" bytes="71963" date_modified="2026-09-29T02:22:14" md5sum="f6d8ad956976ea5e3126f856043dc27b" sha1sum="e7aef949f11f4f235e9853994312e795c21893fb" sha256sum="95cf1f4f6e86cdab68d916be85cf77e26b41b3a061fd11e9fa1ea4bc7bd288b2" sha512sum="9e6dc1c47cc9b07a752f80409b0ad0e4c0f9eda2475a4977db89b2c283856f9cc35d04b12654d6a5ec4620c2fd31e861d348842fce1faf5f3bef8f6684a1c88e">
            <name>FanBoardV01.00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/FanBoardV01.00.fwpkg</url>
            <file_list>
              <file>FanBoardV01.00.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>012e9b54-014d-2e4d-c6ab-8e2977f33d41</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>G13 Fan Board PIC</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>FanBoardV01.00.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>00000000-0000-0000-0000-000095bad5d6</Target>
              <Version>01.00</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="43699ba116594728bcf30612b7c6f5f5">
      <product_version>
        <id product="43699ba116594728bcf30612b7c6f5f5" version="cc4654d8fef8455e967badb8e75df258" lucid_version="nicfwpkg_bcme_57504_4p25@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="17"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57504 Ethernet 10/25Gb 4ポートSFP28アダプター</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcomファームウェアパッケージfor BCM57504 Ethernet 10/25Gb 4ポートSFP28アダプター</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このパッケージには、Broadcom NetXtreme-E BCM57504 Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57504 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol style="list-style-type:decimal">
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">ローカルホストOSの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px"><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3. iLO GUIからのフラッシュ</p>

<ul style="list-style-type:square">
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>

<p><strong><em>追加情報：</em></strong></p>

<ul>
	<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<p>&nbsp;</p>

<ul>
	<li>To update NVM image version 235.1.160.0 and prior versions, please use Broadcom Firmware Package for BCM5750x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5750x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3" target="_blank">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0&nbsp;with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="6">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<p>&nbsp;</p>

<p>&nbsp;</p>

<ul>
	<li>To update NVM image version 235.1.160.0 and prior versions, please use Broadcom Firmware Package for BCM5750x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5750x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-14160fbfa3db428f&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3" target="_blank">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57504_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957504-P425H.fwpkg</filename>
        <component_config/>
        <files>
          <file size="2MB" bytes="3003224" date_modified="2026-09-16T07:51:14" md5sum="f72bca85618cbd1de68c7bd8def2d92b" sha1sum="c320f0e39396a1b3c198bfbdd4bd64dac4ae49de" sha256sum="35d518d583ae5aeefe74944cc72363b610e33e27d929af6666ed8de882746533" sha512sum="a495e73583d441fd8b2fcb05349863e6e4d8e2a4ded0ac463877f1e8e48cf0425ff71a864e37c2d9e35972321515536744a8e33ba3d7fd1d422ba8e4fab4a602">
            <name>BCM238.1.169.0_BCM957504-P425H.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957504-P425H.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957504-P425H.HPb</file>
              <file>BCM238.1.169.0_BCM957504-P425H.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-P425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-175114e41599</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-P425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-180114e41599</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57504 SFP28 Adapter</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>False</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957504-P425H.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>True</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-180414e41599</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Uefi</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="d32e3e2cf68a47998f06cb81ab591bd1">
      <product_version>
        <id product="d32e3e2cf68a47998f06cb81ab591bd1" version="c3c90f140546408cbaf7a30f3130f9cb" lucid_version="isut.deb_x64@6.9.0.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="17"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Integrated Smart Update Tools for Ubuntu Linux x64</name_xlate>
          <name_xlate lang="en">Integrated Smart Update Tools for Ubuntu Linux x64</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Integrated Smart Update Tools for Linux</alt_name_xlate>
          <alt_name_xlate lang="en">Integrated Smart Update Tools for Linux</alt_name_xlate>
        </alt_name>
        <version value="6.9.0.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11447">
            <operating_system_xlate>Ubuntu 24.04 LTS</operating_system_xlate>
          </operating_system>
          <operating_system key="11701">
            <operating_system_xlate>Ubuntu 26.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="SPP"/>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11400032">
          <category_xlate lang="ja">アプリケーション - システム マネジメント</category_xlate>
          <category_xlate lang="en">Application - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="08" day="31" hour="12" minute="11" second="22"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerおよび展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager and an iLO Advanced Pack license for deployment.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>For prerequisite information, please see the <a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25">iSUT Release Notes</a>.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>For prerequisite information, please see the <a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25">iSUT Release Notes</a>.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Download the deb package to a directory on your hard drive and change to that directory. Install by typing dpkg -i&nbsp;sut-XXX_amd64.deb.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download the deb package to a directory on your hard drive and change to that directory. Install by typing dpkg -i&nbsp;sut-XXX_amd64.deb.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="ubuntu2204" major="22" minor="04" sr="OEM" name="Ubuntu 22.04 LTS"/>
            <supported_operating_system platform="ubuntu2404" major="24" minor="04" sr="OEM" name="Ubuntu 24.04 LTS"/>
            <supported_operating_system platform="ubuntu2604" major="26" minor="04" sr="OEM" name="Ubuntu 26.04 LTS"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">102B</supported_device_data>
                <supported_device_data name="dev">053A</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04bd</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="sut" guid="20a6e8e4-bf33-4c71-a6bf-d9ece09b5689">
              <sw_key_expectedpath>software:deb</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>sut-6.9.0-17_amd64.deb</filename>
        <component_config>
          <configuration short_name="sut.linux" lang="en">
            <parameter name="PollingIntervalInMinutes">
              <depends>
                <dependent name="" value=""/>
              </depends>
              <user_prompt>
	Enter Polling interval in minutes. Minimum 5 minutes Maximum 1440 minutes. 
  </user_prompt>
              <default value="5"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="5" encrypt="0"/>
              <requirements>
                <required_for_installation value="NO"/>
                <!--Required fields for installation. Value is YES indicates must paramter for the deployment -->
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>12</maximum_length>
                  <acceptable_characters>
		0-9
	  </acceptable_characters>
                  <required_format>
		*
	  </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
            </parameter>
            <parameter name="Mode">
              <user_prompt>
        Mode in which SUT runs. 
      </user_prompt>
              <default value="AutoDeploy;AutoStage;AutoDeployReboot;OnDemand"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="OnDemand" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>24</maximum_length>
                  <acceptable_characters>
            *
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
            <parameter name="StagingDirectory">
              <user_prompt>
        Enter the directory where the staging has to be done. The default path for staging directory is /var/tmp/sut/stagingdirectory.
      </user_prompt>
              <default value=""/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>255</maximum_length>
                  <acceptable_characters>
            0..9A..Z;a..z;-/
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
          </configuration>
        </component_config>
        <files>
          <file size="18MB" bytes="19625432" date_modified="2026-09-11T00:23:02" md5sum="e552422842253f89d1fdddec55f8d33d" sha1sum="48c0b335860d91fa57c6a370a97f108bb30b188e" sha256sum="a1c117bc23345ac68004f637b9a631acbc1adb5e79ebc88514dfa57226cababf" sha512sum="3ad4ce0dd94522d856637fe62d4367261841de72cc5ffd680fa92edd993eae47f503034560db8d90350325a76cd2e86ba8849163e100fe6e3a86520b58f326bc" version="6.9.0">
            <name>sut-6.9.0-17_amd64.deb</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/sut-6.9.0-17_amd64.deb</url>
            <file_list>
              <file>./README.txt</file>
              <file>./opt/hp/hpsut/README.txt</file>
              <file>./opt/sut/README.txt</file>
              <file>./opt/sut/bin/gatherlogs.sh</file>
              <file>./opt/sut/bin/hpsut</file>
              <file>./opt/sut/bin/sut</file>
              <file>./opt/sut/bin/x64/sum_drop_table_x64</file>
              <file>./opt/sut/config/sut_cfg_default.dat</file>
              <file>./opt/sut/doc/OnDemandHelp.txt</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libQt5Core.so.5</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libdouble-conversion.so.3</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70.1</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70.1</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70.1</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libpcre2-16.so.0</file>
              <file>./opt/sut/schemas/SUT.json</file>
              <file>./opt/sut/schemas/SUTProvider.json</file>
              <file>./opt/sut/schemas/SUTProvider_Gen10.json</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Redfish.json</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettings.json</file>
              <file>./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettings_Gen10.json</file>
              <file>./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTTasksettings.json</file>
              <file>./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUT_Gen10.json</file>
              <file>./opt/sut/scripts/sut.service</file>
              <file>./opt/sut/scripts/sutd</file>
              <file>./usr/share/doc/sut/changelog.gz</file>
              <file>./usr/share/doc/sut/copyright</file>
              <file>./usr/share/man/man8/sut.8.gz</file>
              <file>./usr/share/smartupdate/sut/component.xml</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70</file>
              <file>./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="36f6995b3d78461cb08bfc4c75a416f6">
      <product_version>
        <id product="36f6995b3d78461cb08bfc4c75a416f6" version="13b806cff46044c496bcc32ddd98108f" lucid_version="bnxt_roce.sles16sp0@238.1.165.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="6"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">SUSE Linux Enterprise Server 16 SP0向けHPE Broadcom NetXtreme-E RoCEライブラリ</name_xlate>
          <name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 16 SP0</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">SUSE Linux Enterprise Server 16 SP0向けHPE Broadcom NetXtreme-E RoCEライブラリ</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 16 SP0</alt_name_xlate>
        </alt_name>
        <version value="238.1.165.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品は、SUSE Linux Enterprise Server 16 SP0下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE (RDMA over Converged Ethernet) ライブラリを含んでいます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 16 SP0.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>この製品をインストールする前に、<em>HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16</em>、バージョン1.10.3-237.1.137.0以降をインストールする必要があります。</p>

<p>RoCEライブラリをインストールする前に、ターゲットシステムにlibibverbおよびrdma-coreパッケージをインストールしておく必要があります。まだインストールしていない場合は、オペレーティングシステムのインストールメディアからパッケージを取得できます。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p><em>HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16</em>, version 1.10.3-237.1.137.0 or later, must be installed before installing this product.</p>

<p>The libibverb and rdma-core package must be installed on the target system prior to the installation of the RoCE library. If not already present, the packages can be obtained from the operating system installation media.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh <bnxt_rooce >.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="text-align:left">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E120</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D7</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D8</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0212</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1593</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1592</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EB</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1595</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1594</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1597</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1596</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E122</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E322</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0211</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">020E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16ED</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02C5</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E124</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E324</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1801</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14e4</supported_device_data>
                <supported_device_data name="dev">1804</supported_device_data>
                <supported_device_data name="subven">14e4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1760</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E116</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1599</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1751</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1598</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">16D7</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="libbnxt_re" guid="20a6e8e4-bf33-4c71-a6bf-d9ecff04767d">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>libbnxt_re-238.1.165.0-sles16sp0.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="282KB" bytes="288791" date_modified="2026-09-03T03:45:21" md5sum="cb416894102a97b5e8d342b0c5d65ef1" sha1sum="65aa077e1a931304239743bc50e98ba8c58dcbd7" sha256sum="276b18128b37589744ba67a5c1efbc69c6d48e633f411eba99af1a2e30a66901" sha512sum="a0868df1c2e2e06af74a93a6d5676023a70b4382d5a886e16fe026ca75af9ca56b67b0fdb9fd7c560a810cfc5af007f0b5dbd1bd94ae8de3e2e865781d4caadf" version="238.1.165.0" release="sles16sp0">
            <name>libbnxt_re-238.1.165.0-sles16sp0.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/libbnxt_re-238.1.165.0-sles16sp0.x86_64.rpm</url>
            <file_list>
              <file>./etc/libibverbs.d/bnxt_re.driver</file>
              <file>./usr/lib64/libbnxt_re-238.1.165.0.so</file>
              <file>./usr/lib64/libbnxt_re-rdmav34.so</file>
              <file>./usr/lib64/libbnxt_re.so</file>
              <file>./usr/lib64/pkgconfig/libbnxt_re.pc</file>
              <file>./usr/share/smartupdate/libbnxt_re/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="23452ce6ae6f410f8e11e448b677d128">
      <product_version>
        <id product="23452ce6ae6f410f8e11e448b677d128" version="b29ff3d02e4e46708140d9b6dacac53e" lucid_version="HPE_MR416i-o_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="8"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR416i-o Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR416i-o Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-o Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-o Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="46"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR416i-o Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR416i-o Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03281590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR416i-o_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521090" date_modified="2026-09-21T04:44:18" md5sum="6fc0825a6d049ce78c23186b8de85f6b" sha1sum="6c167cee53f6acc08c5a21c6e92a56783124d6a5" sha256sum="3ecbcb2c5ba9689f8350742a40b97b89544900542fb40514dd86cb76033c3d94" sha512sum="b6a6f880f93c3025406f098b1289caf338304431e57923818784f1c2d8f995b818d3614d71888f28c5cdfd41e00dd611d0dc601b556608ef6116db8f6786de82">
            <name>HPE_MR416i-o_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR416i-o_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR416i-o_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR416i-o_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR416i-o_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR416i-o_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e215900328</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>52.26.3.5487</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="3013cefa4fe14260a6f6811796f9b1c0">
      <product_version>
        <id product="3013cefa4fe14260a6f6811796f9b1c0" version="81f2f117928541698f4d9a2ce9183fc9" lucid_version="Gen10P_Gen11_Gen12_hpemrsa.rhel10@8.18.11.0__pubsw-linux_de,en,es,fr,it,ja"/>
        <different>new</different>
        <build number="12"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)</name_xlate>
          <name_xlate lang="en">HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)</alt_name_xlate>
        </alt_name>
        <version value="8.18.11.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="7800032">
          <category_xlate lang="ja">ソフトウェア - システム マネジメント</category_xlate>
          <category_xlate lang="en">Software - System Management</category_xlate>
        </category>
        <languages langlist="en,fr,it,de,es,ja">
          <languages_xlate lang="ja">英語（US）,フランス語,イタリア語,ドイツ語,スペイン語,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),French,Italian,German,Spanish,Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="02" hour="01" minute="50" second="23"/>
        <description>
          <description_xlate lang="ja"><![CDATA[HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. ]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>
	<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>
	<li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li>
	<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>
	<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>
	<li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<ul>
	<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>
	<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>
	<li>Use &quot;rpm&nbsp;-Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li>
	<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>
	<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>
	<li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">00B3</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0453</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="MRStorageAdministrator" guid="20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="28MB" bytes="29975308" date_modified="2026-09-04T13:12:19" md5sum="44691c8daa10b7711517111b30f91c0c" sha1sum="0cdda248b49c9e7736b71cd01c7a820756394634" sha256sum="1b5535121f39e2e1f4e6b68568e9a698d3068d9abeab55f4c7811737732888c0" sha512sum="2ba0e170790dbd3beb014e46ca505627188c45717ec7bb7ce773b7457d952d36249a2d50c66248d9b34ed45dfc25281f7c44d12539bae96133c289a0914c094d" version="008.018.011.000" release="00.rhel10">
            <name>MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.rpm</url>
            <file_list>
              <file>./etc/init.d/LsiSASH</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/LSA</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/bin/temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/report</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/README</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/97AB61D67CC8D4791C6CB34B01AEDD99.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/53EF515E4B68F4375CDAB62B8BF5DF72.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/59AE9E2C0EDDF3AAB8FA2CAAE04CA10B.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/2EE840FAFCB91D1EAD07D1F6BA3F09A2.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/B607368818C162A84762061F2C356C99.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/5F36DB58B87376D92AE07C107220CAFC.cache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/nginx</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/start.log</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh</file>
              <file>./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/00</file>
              <file>./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671</file>
              <file>./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671.1</file>
              <file>./usr/lib/.build-id/0d</file>
              <file>./usr/lib/.build-id/0d/8aa3aa399ec364adf42205be9468b804983669</file>
              <file>./usr/lib/.build-id/1e</file>
              <file>./usr/lib/.build-id/1e/4ab9e5ac3873f1e9e96ccb8d456aa9b8c8421e</file>
              <file>./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651</file>
              <file>./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651.1</file>
              <file>./usr/lib/.build-id/22</file>
              <file>./usr/lib/.build-id/22/6d68df44845b0c7dc5ef410f3f668e54d98d4a</file>
              <file>./usr/lib/.build-id/29</file>
              <file>./usr/lib/.build-id/29/5ebed48961c1f0be76d28e65e4ad918a48d7a9</file>
              <file>./usr/lib/.build-id/33</file>
              <file>./usr/lib/.build-id/33/458cfa214cc81fc145bd5f6907efd7e0aafd1b</file>
              <file>./usr/lib/.build-id/3d</file>
              <file>./usr/lib/.build-id/3d/38c62e56eb18f90588f0c0671b2649c0f19429</file>
              <file>./usr/lib/.build-id/3e</file>
              <file>./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379</file>
              <file>./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379.1</file>
              <file>./usr/lib/.build-id/69</file>
              <file>./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9</file>
              <file>./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9.1</file>
              <file>./usr/lib/.build-id/6c</file>
              <file>./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378</file>
              <file>./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378.1</file>
              <file>./usr/lib/.build-id/7d</file>
              <file>./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60</file>
              <file>./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60.1</file>
              <file>./usr/lib/.build-id/8c</file>
              <file>./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42</file>
              <file>./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42.1</file>
              <file>./usr/lib/.build-id/93</file>
              <file>./usr/lib/.build-id/93/7ff067ea0ac8b14a9d72809610cf202fba9bcb</file>
              <file>./usr/lib/.build-id/a1</file>
              <file>./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4</file>
              <file>./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4.1</file>
              <file>./usr/lib/.build-id/a2</file>
              <file>./usr/lib/.build-id/a2/0980fd24b5096e329b22ef027bce82656c8a3b</file>
              <file>./usr/lib/.build-id/a9</file>
              <file>./usr/lib/.build-id/a9/c802296b807a1d057ab3d0a55348bf07e14390</file>
              <file>./usr/lib/.build-id/b1</file>
              <file>./usr/lib/.build-id/b1/283a31fc643caa7e0c8ac92a4b38efa6b20b24</file>
              <file>./usr/lib/.build-id/c3</file>
              <file>./usr/lib/.build-id/c3/60ad11822954dfc9c8dfe8a8d78966318c0a90</file>
              <file>./usr/lib/.build-id/cf</file>
              <file>./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425</file>
              <file>./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425.1</file>
              <file>./usr/lib/.build-id/d6</file>
              <file>./usr/lib/.build-id/d6/8f1a74a48ef91989b2522a2059876facfdf263</file>
              <file>./usr/lib/.build-id/e1</file>
              <file>./usr/lib/.build-id/e1/8de4be87dc2c1a42d5d3bde990aa9bc5f99d66</file>
              <file>./usr/lib/.build-id/e3</file>
              <file>./usr/lib/.build-id/e3/dce544ac29ba70ee7deffb7c53adc4d0c45ba3</file>
              <file>./usr/share/smartupdate/MRStorageAdministrator/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="aa57601c0db347e68c835baf96f72938">
      <product_version>
        <id product="aa57601c0db347e68c835baf96f72938" version="016c736d7d524e2a8f61b0afff012dbe" lucid_version="HPE_MR408i-o_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="7"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR408i-o Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR408i-o Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR408i-o Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR408i-o Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="SPP"/>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="40"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR408i-o Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR408i-o Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03C81590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR408i-o_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521215" date_modified="2026-09-21T04:43:18" md5sum="1b419ac6d702871c344f586390267535" sha1sum="f878946fcb9ca91bdb92e894c6e6a119e0b09769" sha256sum="bf8985ff67b07a2f76f222f97684e880313210b64f304aadbad2f6dbf4029d94" sha512sum="b6611de2781f0d5c608dc7d7ac27e42173cf4382dec928329e45830ff5af210e6614a85fe7da18165d24e7f51ef23a7177729d820c0010566114f877ca2d768c">
            <name>HPE_MR408i-o_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR408i-o_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR408i-o_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR408i-o_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR408i-o_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR408i-o_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e2159003c8</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>52.26.3.5487</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="378cdf1de2de48e7bfb2a8d18ef9e12e">
      <product_version>
        <id product="378cdf1de2de48e7bfb2a8d18ef9e12e" version="689c3d000b2543e4b58f8eaf4d6938ce" lucid_version="HPE_MR216i-p_Gen11@52.38.3-6909__fwpkg-generic_en"/>
        <different>new</different>
        <build number="11"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">ファームウェアパッケージ - HPE MR216i-p Gen11トライモードコントローラー</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE MR216i-p Gen11 Tri Mode Controller</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR216i-p Gen11トライモードコントローラー</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR216i-p Gen11 Tri Mode Controller</alt_name_xlate>
        </alt_name>
        <version value="52.38.3-6909" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="38"/>
        <description>
          <description_xlate lang="ja"><![CDATA[ユニバーサルファームウェアPLDMファイルfor HPE MR216i-p Gen11トライモードコントローラー]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE MR216i-p Gen11 Tri Mode Controller]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6バージョンは少なくとも1.53である必要があり、<strong>シャーシとファブリックのサポート</strong>に必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>iLO6 version should be at least&nbsp;1.53 is required for&nbsp;<strong>chassis&amp;Fabric support.</strong></p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078">RESTful Interface Tool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p>localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p><br />
This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</li>
	<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</li>
</ul>

<p>Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp;</p>

<p>Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
</ul>

<p>&nbsp;</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="8000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>1200</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03261590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_MR216i-p_Gen11_52.38.3-6909_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7521092" date_modified="2026-09-21T05:27:13" md5sum="b483c498f8b1f24df4e82eb245b30071" sha1sum="e2cb5e17c38406f65bc8c22e3ba42b637b1a8a2b" sha256sum="c57b7f8619cf86a9ba7e0a9a97878033fde5aef2771e7bc341a3d650da60ca75" sha512sum="8e09cb83092f65b7fbcec116ea0b1079878d685ec1359770ec0099defec5e945b487b13f532d836ec69cb4a8f29fbc52fa8d6f9feafaf0e1777f058f6eff65ae">
            <name>HPE_MR216i-p_Gen11_52.38.3-6909_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_MR216i-p_Gen11_52.38.3-6909_A.fwpkg</url>
            <file_list>
              <file>HPE_MR216i-p_Gen11_52.38.3-6909_A.HPb</file>
              <file>HPE_MR216i-p_Gen11_52.38.3-6909_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_MR216i-p_Gen11</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_MR216i-p_Gen11_52.38.3-6909_A.HPb</FileName>
                <InstallDurationSec>1200</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1000-10e215900326</Target>
              <Version>52.38.3-6909</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>52.26.3.5487</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="5d636f95f482471a9bd020c928d3b4af">
      <product_version>
        <id product="5d636f95f482471a9bd020c928d3b4af" version="4a4df0491dad41fc9dfff517e38686d7" lucid_version="HPE_NS204i_Gen10P_Gen11_Gen12@1.2.14.1034__fwpkg-generic_en"/>
        <different>new</different>
        <build number="18"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Firmware Package - HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Firmware Package - HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204</alt_name_xlate>
          <alt_name_xlate lang="en">Firmware Package - HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204</alt_name_xlate>
        </alt_name>
        <version value="1.2.14.1034" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900214">
          <category_xlate lang="ja">ファームウェア - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Firmware - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="07" day="25" hour="08" minute="24" second="22"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Universal Firmware PLDM file for the HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Universal Firmware PLDM file for the HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>Gen11およびGen12サーバーにはiLO 6バージョン1.10以降が必要です。</li>
	<li>Gen10/Gen10 PlusサーバーにはiLO 5バージョン2.81以降が必要です。</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<ul>
	<li>iLO 6&nbsp;version 1.10 or later is required for Gen11 and Gen12&nbsp;&nbsp;servers.</li>
	<li>iLO 5 version 2.81 or later is required for Gen10/Gen10 Plus&nbsp;servers</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager (SUM) を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。  iLOrestツールの最新バージョンをダウンロードします。</p>

<p>    ローカルホストOSの例：<br />
<strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p>    リモートの例：<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager (SUM) の最新バージョンでもインストールできます。</p>

<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li>
	<p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li>
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3. iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ (IML) にログエントリーが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command.&nbsp; Download the latest version of the iLOrest tool.</p>

<p>&nbsp; &nbsp; localhost OS example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p>&nbsp; &nbsp; remote example:<br />
<strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li>
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p>
	</li>
	<li>
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p>

<p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="ubuntu2204" major="22" minor="04" sr="OEM" name="Ubuntu 22.04 LTS"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0379</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">02F6</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0380</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">030E</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0455</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0310</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">030F</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1B4B</supported_device_data>
                <supported_device_data name="dev">2241</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04C4</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="32000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>600</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="03791590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="03801590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="02F61590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="030E1590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="04551590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="030F1590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="03101590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="04C41590" guid="">
              <sw_key_expectedpath>firmware</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>HPE_NS204i_1.2.14.1034_A.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7392032" date_modified="2026-09-18T09:11:15" md5sum="97c3d89b31719d0543745b0885fcc95a" sha1sum="72ca69fa663d65823a82f328e55a402918b4a504" sha256sum="7bbc89fec09f8a461881f1dcf03075bb28243b54d2150cc3d4ee0df04551647c" sha512sum="0d1d275d1eacc0876eb53d4aab15dff821e365a6c61b5524b2fd9a8e4902fe5e7e6a168e06637e7e8ccdc6bdc28185a1537fc1ff98f378ab1ad1001584401f3a">
            <name>HPE_NS204i_1.2.14.1034_A.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/HPE_NS204i_1.2.14.1034_A.fwpkg</url>
            <file_list>
              <file>HPE_NS204i_1.2.14.1034_A.HPb</file>
              <file>HPE_NS204i_1.2.14.1034_A.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-224115900379</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-224115900380</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-2241159002f6</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-22411590030e</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-224115900455</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-22411590030f</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-224115900310</Target>
              <Version>1.2.14.1034</Version>
            </Device>
            <Device>
              <DeviceName>HPE_NS204i_1.2.14.1034</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>HPE_NS204i_1.2.14.1034_A.HPb</FileName>
                <InstallDurationSec>600</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-1b4b-2241159004c4</Target>
              <Version>1.2.14.1034</Version>
            </Device>
          </Devices>
          <MinimumActiveVersion>1.2.14.1018</MinimumActiveVersion>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="ae86717eaef841a7919ea42f85ca3fe7">
      <product_version>
        <id product="ae86717eaef841a7919ea42f85ca3fe7" version="5be1cfb2626b4cceb0bd3f33eb62267d" lucid_version="Gen10P_Gen11_MR_Controller.win2025@7.738.8.0__sc-windows_en"/>
        <different>new</different>
        <build number="8"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10pコントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o 、MR408i-p Gen11コントローラードライバーfor Microsoft Windows 2025 edition</name_xlate>
          <name_xlate lang="en">HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10pコントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o 、MR408i-p Gen11コントローラードライバーfor Microsoft Windows 2025 edition</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition</alt_name_xlate>
        </alt_name>
        <version value="7.738.8.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300214">
          <category_xlate lang="ja">ドライバ - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Driver - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="21"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このドライバー、MegaSAS35は、HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a Gen10p コントローラーおよびMR416i-o、MR416i-p、MR216i-o、MR216i-p、MR408i-o、MR408i-p Gen11コントローラー用のWindows 2025 64ビットのサポートを提供します。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This driver, MegaSAS35, provides Windows 2025 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="1440"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>400</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="MegaSas35.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp071620.exe</filename>
        <component_config/>
        <files>
          <file size="922KB" bytes="944464" date_modified="2026-09-03T04:08:13" md5sum="fdca10cf26b0bb682f21daf4e552b35b" sha1sum="27672e2ac1a1818c56aa91fcd6e41bd208c4a76f" sha256sum="419c59aa2f4c96cfa2220aea9b7978de2ceb316bc3e49cd6ce31b7b7ff14053d" sha512sum="5a47f658e2269e3709d9b2c42b1f89a7e8be5f6a5224f31160a4f373b78211d2915046617650f485654dc57cbd376be4712a12a36022d86e4cf8a09ca1f77e68">
            <name>cp071620.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp071620.exe</url>
            <file_list>
              <file>cp071620.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>generic.dll</file>
              <file>install.xml</file>
              <file>megasas35.cat</file>
              <file>megasas35.inf</file>
              <file>megasas35.pdb</file>
              <file>megasas35.RttMeta</file>
              <file>megasas35.sys</file>
              <file>nodev.inf</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="8e8482d9e6e6494a8e54ec40143d190a">
      <product_version>
        <id product="8e8482d9e6e6494a8e54ec40143d190a" version="489e6ca1dfb34e93ae41e9130351fd05" lucid_version="tg3.sles15@3.140b-2__pubsw-linux_en"/>
        <different>changed</different>
        <build number="3"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="3.140b-2" revision="" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>ユーザーがOOBドライバーをすぐに有効にしたい場合、OOBドライバーをインストールする前にインボックスNICドライバーをアンロードするために、この製品が必要です。それ以外の場合、OOBドライバーは、インボックスドライバーがロードされた状態でシステムを再起動した後に有効になります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This product is required to unload inbox NIC driver before install OOB driver if user want OOB driver to take effect immediately. Otherwise, OOB driver will take effect after system reboot under inbox driver is loaded.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>インストール手順についてのREADMEをダウンロードします。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download README for installation instructions.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1591</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">1590</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1665</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22E8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">1786</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">169D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">22BE</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">1657</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">3383</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">165F</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">159C</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="tg3-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="tg3-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="129KB" bytes="132341" date_modified="2026-09-03T03:02:57" md5sum="c215bb7c92f7279faf29507b6aa44ff6" sha1sum="b7c32ea04391ebfa3195eb935c3c1e1982ecb3db" sha256sum="3cc64cb79f24a1ff64fe3fe4e11546f06d712e39f50fc0ade0c09a2397d538a2" sha512sum="3e307ad6d9c2d6c48c84304140b7a49ab62795f9274348d8b8815ba2fe9ac0737a14a6338cff8932da5912070d144f33c659ef6c6b149c33dcb2b9daa09678df" version="3.140b_k6.4.0_150600.21" release="2.sles15sp6">
            <name>tg3-kmp-default-3.140b_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/tg3-kmp-default-3.140b_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/tg3.ko</file>
              <file>./usr/share/smartupdate/tg3-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="130KB" bytes="134096" date_modified="2026-09-03T03:08:01" md5sum="e0619f6eb1cb9b6769cce9556a8cf2af" sha1sum="537aa71302ee3f692aafbdcf50dcc3a2949456b3" sha256sum="964ec49128dffcc8266e11691de0ee272848301c9d9ff164f576ec2a3a2ffd56" sha512sum="b6e68b9e31f4ae85a8f8d69131450d9a988f5fb7e0d1ded70fa8ce62979a69648102a018c7b9a00bacf95c029df4ff79566f4f4b19d2879d29c3d928cfeac280" version="3.140b_k6.4.0_150700.51" release="2.sles15sp7">
            <name>tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/tg3.ko</file>
              <file>./usr/share/smartupdate/tg3-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="3ab4de78da484144892d6ddcd8fd9b97">
      <product_version>
        <id product="3ab4de78da484144892d6ddcd8fd9b97" version="d004682c90d34e4dbdb3d3289a125869" lucid_version="ixgbe.sles15@6.4.4-1(B)__pubsw-linux_en"/>
        <different>changed</different>
        <build number="1"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15</name_xlate>
          <name_xlate lang="en">HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15</alt_name_xlate>
        </alt_name>
        <version value="6.4.4-1" revision="B" type_of_change="1"/>
        <manufacturer_name/>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="44"/>
        <description>
          <description_xlate lang="ja"><![CDATA[この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>

<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>

<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>

<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>

<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li>
</ul>

<p style="margin-left:40px">* 以前のWebリリースixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません <br />
    - RPMパッケージ名は（<strong>hp</strong>-ixgbe-kmp-default）から（igb-ixgbe-default）に変更されました。この変更を（ixgbe-kmp-default）から（<strong>hp</strong>-ixgbe-kmp-default）に戻しました。<br />
    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />
* <strong>hp</strong>-ixgbe-kmp-defaultとixgbe-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />
  混乱を避けるため、すでにixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbe-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li>
</ul>

<p style="margin-left:40px">* The previous web release ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;<br />
&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe-kmp-default) to (igb-ixgbe-default). Now we revert this change from (ixgbe-kmp-default) to (<strong>hp</strong>-ixgbe-kmp-default).<br />
&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />
* <strong>hp</strong>-ixgbe-kmp-default and ixgbe-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />
&nbsp; To avoid confusion, if you already download and install ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbe-kmp-default and then install the updated RPM.</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10FB</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1528</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D2</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1563</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00D1</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">152E</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D0</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">10ED</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">17D3</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1530</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">192D</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">1515</supported_device_data>
                <supported_device_data name="subven">103C</supported_device_data>
                <supported_device_data name="subdev">211A</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="hp-ixgbe-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="hp-ixgbe-kmp-default" guid="20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="6MB" bytes="7313020" date_modified="2026-09-02T09:55:12" md5sum="fa333f83f1e7b426e0090e8d729058bd" sha1sum="b746cb12108e5be06fe4a8ee7c4bfa573654a2e7" sha256sum="29853d39abe8e9969286d35062f309387c81a153b195015b52679b3e880e6c78" sha512sum="c821b81be65406badcd9356c4a8c2a0bce0d3405f26611117d1aa5e85338f4890a164a7061d92e9fa88dee9ba0cac430584f7765fd9afbc41013f25b288acdee" version="6.4.4_k6.4.0_150600.21" release="1.sles15sp6">
            <name>hp-ixgbe-kmp-default-6.4.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/hp-ixgbe-kmp-default-6.4.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbe.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbe-oob.conf</file>
              <file>./lib/modules/6.4.0-150600.21-default</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe</file>
              <file>./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe/ixgbe.ko</file>
              <file>./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml</file>
            </file_list>
          </file>
          <file size="382KB" bytes="392133" date_modified="2026-09-02T09:59:28" md5sum="9c75b94b3dce2f1343bc6ccb1c9e8001" sha1sum="709c3dfa4b54bde5a7943dd03d898cd40bd7e7ef" sha256sum="df9c390502b2727d9d436ca4a5ce351362ef0a3e5dd31675c07911c1497f7b57" sha512sum="2a8689c40573ed86b4e727ca8a77205e6982f813ec00f5bfcdc5fb26d8c9235abce31fd73cfbd13a840a14c6a557278dd05d840b33ecf3a2713490c0e85056bf" version="6.4.4_k6.4.0_150700.51" release="1.sles15sp7">
            <name>hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/hp-ixgbe.conf</file>
              <file>./etc/dracut.conf.d/hp-ixgbe-oob.conf</file>
              <file>./lib/modules/6.4.0-150700.51-default</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe</file>
              <file>./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe/ixgbe.ko</file>
              <file>./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="b3a8e7e2c4ea466a9b404955f474449e">
      <product_version>
        <id product="b3a8e7e2c4ea466a9b404955f474449e" version="0d079a2f41b0438cbb6b475d68f45838" lucid_version="isut.linux_x64@6.9.0.0__pubsw-linux_en"/>
        <different>changed</different>
        <build number="75"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">Integrated Smart Update Tools for Linux x64</name_xlate>
          <name_xlate lang="en">Integrated Smart Update Tools for Linux x64</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Integrated Smart Update Tools for Linux</alt_name_xlate>
          <alt_name_xlate lang="en">Integrated Smart Update Tools for Linux</alt_name_xlate>
        </alt_name>
        <version value="6.9.0.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="SPP"/>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11400032">
          <category_xlate lang="ja">アプリケーション - システム マネジメント</category_xlate>
          <category_xlate lang="en">Application - System Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="08" day="31" hour="12" minute="14" second="09"/>
        <description>
          <description_xlate lang="ja"><![CDATA[Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>前提条件の詳細については、『<a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25">iSUTリリースノート</a>』をご覧ください。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>For prerequisite information, please see the <a href="https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25">iSUT Release Notes</a>.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh sut-XXX.x86_64.rpm.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh sut-XXX.x86_64.rpm.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">00E4</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103C</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03BA</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">102B</supported_device_data>
                <supported_device_data name="dev">053A</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04bd</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
          <minimum_active_version value="5.3.0"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="sut" guid="20a6e8e4-bf33-4c71-a6bf-d9ece09b5689">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>sut-6.9.0-75.linux.x86_64.rpm</filename>
        <component_config>
          <configuration short_name="sut.linux" lang="ja">
            <parameter name="PollingIntervalInMinutes">
              <depends>
                <dependent name="" value=""/>
              </depends>
              <user_prompt>
	Enter Polling interval in minutes. Minimum 5 minutes Maximum 1440 minutes. 
  </user_prompt>
              <default value="5"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="5" encrypt="0"/>
              <requirements>
                <required_for_installation value="NO"/>
                <!--Required fields for installation. Value is YES indicates must paramter for the deployment -->
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>12</maximum_length>
                  <acceptable_characters>
		0-9
	  </acceptable_characters>
                  <required_format>
		*
	  </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
            </parameter>
            <parameter name="Mode">
              <user_prompt>
        Mode in which SUT runs. 
      </user_prompt>
              <default value="AutoDeploy;AutoStage;AutoDeployReboot;OnDemand"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="OnDemand" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>24</maximum_length>
                  <acceptable_characters>
            * 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
            <parameter name="StagingDirectory">
              <user_prompt>
        Enter the directory where the staging has to be done. The default path for staging directory is /var/tmp/sut/stagingdirectory.
      </user_prompt>
              <default value=""/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>255</maximum_length>
                  <acceptable_characters>
            0..9A..Z;a..z;-/ 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
          </configuration>
          <configuration short_name="sut.linux" lang="en">
            <parameter name="PollingIntervalInMinutes">
              <depends>
                <dependent name="" value=""/>
              </depends>
              <user_prompt>
	Enter Polling interval in minutes. Minimum 5 minutes Maximum 1440 minutes. 
  </user_prompt>
              <default value="5"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="5" encrypt="0"/>
              <requirements>
                <required_for_installation value="NO"/>
                <!--Required fields for installation. Value is YES indicates must paramter for the deployment -->
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>12</maximum_length>
                  <acceptable_characters>
		0-9
	  </acceptable_characters>
                  <required_format>
		*
	  </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
            </parameter>
            <parameter name="Mode">
              <user_prompt>
        Mode in which SUT runs. 
      </user_prompt>
              <default value="AutoDeploy;AutoStage;AutoDeployReboot;OnDemand"/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="OnDemand" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>24</maximum_length>
                  <acceptable_characters>
            * 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
            <parameter name="StagingDirectory">
              <user_prompt>
        Enter the directory where the staging has to be done. The default path for staging directory is /var/tmp/sut/stagingdirectory.
      </user_prompt>
              <default value=""/>
              <output type="file_variable" filename="/usr/local/sut/sut_cfg.dat" value="" encrypt="0"/>
              <requirements>
                <required_for_installation value="no"/>
                <input_requirements>
                  <minimum_length>0</minimum_length>
                  <maximum_length>255</maximum_length>
                  <acceptable_characters>
            0..9A..Z;a..z;-/ 
          </acceptable_characters>
                  <required_format>
            *
          </required_format>
                  <user_visible value="yes"/>
                  <user_editable value="yes"/>
                  <password_field value="no"/>
                </input_requirements>
              </requirements>
              <depends>
                <dependent name="" value=""/>
              </depends>
            </parameter>
          </configuration>
        </component_config>
        <files>
          <file size="9MB" bytes="9829038" date_modified="2026-09-24T03:55:05" md5sum="e480bc50c663434ef5188dd71dc5d7d4" sha1sum="77ff1edf01e2bd8e9d2fca43fc5bec268eeee04c" sha256sum="1876654dadb14abb64ba28e7a780688ae305a593ee998312b0bbc7754005978d" sha512sum="db743571d8e57ef1a8d366e48c11edf72931d3363ae42f30ccd003d957ca219277d5df628d1bf985c53787a4f32f077dad3d5490a0e98c1b882bbba07424c9b5" version="6.9.0" release="75.linux">
            <name>sut-6.9.0-75.linux.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/sut-6.9.0-75.linux.x86_64.rpm</url>
            <file_list>
              <file>./opt/hp/hpsut/README.txt</file>
              <file>./opt/sut/README.txt</file>
              <file>./opt/sut/bin/gatherlogs.sh</file>
              <file>./opt/sut/bin/hpsut</file>
              <file>./opt/sut/bin/sut</file>
              <file>./opt/sut/bin/x64/sum_drop_table_x64</file>
              <file>./opt/sut/config/sut_cfg_default.dat</file>
              <file>./opt/sut/doc/OnDemandHelp.txt</file>
              <file>./opt/sut/schemas/SUT.json</file>
              <file>./opt/sut/schemas/SUTProvider.json</file>
              <file>./opt/sut/schemas/SUTProvider_Gen10.json</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Redfish.json</file>
              <file>./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettings.json</file>
              <file>./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSettings_Gen10.json</file>
              <file>./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTTasksettings.json</file>
              <file>./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz</file>
              <file>./opt/sut/schemas/SUT_Gen10.json</file>
              <file>./opt/sut/scripts/sut.service</file>
              <file>./opt/sut/scripts/sutd</file>
              <file>./usr/lib/.build-id</file>
              <file>./usr/lib/.build-id/08</file>
              <file>./usr/lib/.build-id/08/816b227696b91815670f9329216c873743e950</file>
              <file>./usr/lib/.build-id/95</file>
              <file>./usr/lib/.build-id/95/14bec01bfd84c7aed6f15532b3d7373e2b5853</file>
              <file>./usr/share/man/man8/sut.8.gz</file>
              <file>./usr/share/smartupdate/sut/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="27ca75a0a65a4233a7c6cb56ff8dd03a">
      <product_version>
        <id product="27ca75a0a65a4233a7c6cb56ff8dd03a" version="33cf434d7d204a4a8dd691f2261a6519" lucid_version="iLO8.fwpkg@1.10.00__fwpkg-ilo_en"/>
        <different>new</different>
        <build number="32"/>
        <type id="universal-fw-ilo"/>
        <name>
          <name_xlate lang="ja">Firmware Package - HPE Integrated Lights-Out 8</name_xlate>
          <name_xlate lang="en">Firmware Package - HPE Integrated Lights-Out 8</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE Integrated Lights-Out 8</alt_name_xlate>
          <alt_name_xlate lang="en">HPE Integrated Lights-Out 8</alt_name_xlate>
        </alt_name>
        <version value="1.10.00" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
          <operating_system key="11701">
            <operating_system_xlate>Ubuntu 26.04 LTS</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="64">
            <division_xlate lang="ja">Lights Out</division_xlate>
            <division_xlate lang="en">Lights Out</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900213">
          <category_xlate lang="ja">ファームウェア - Lights-Outマネジメント</category_xlate>
          <category_xlate lang="en">Firmware - Lights-Out Management</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="25" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p><strong>Prerequisite for flashing fwpkg.</strong></p>

<p>1. Download &quot;.fwpkg&quot;</p>

<p>2. Copy the contents from &quot;.json&quot; and create a file with the same name and save it in .json format [different file name and formats are not supported]</p>

<p>3. Place the files mentioned in 1 and 2 under the same folder</p>

<p>&nbsp;</p>

<p>Now follow the steps&nbsp;mentioned in the Installation Notes for flashing the fwpkg.</p>

<p>&nbsp;</p>

<p>Hewlett Packard Enterprise recommends the following or greater versions of iLO utilities<br />
for best performance:</p>

<ul>
	<li>RESTful Interface Tool (iLOREST) 7.4.0.0 or&nbsp;later</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p><strong>Prerequisite for flashing fwpkg.</strong></p>

<p>1. Download &quot;.fwpkg&quot;</p>

<p>2. Copy the contents from &quot;.json&quot; and create a file with the same name and save it in .json format [different file name and formats are not supported]</p>

<p>3. Place the files mentioned in 1 and 2 under the same folder</p>

<p>&nbsp;</p>

<p>Now follow the steps&nbsp;mentioned in the Installation Notes for flashing the fwpkg.</p>

<p>&nbsp;</p>

<p>Hewlett Packard Enterprise recommends the following or greater versions of iLO utilities<br />
for best performance:</p>

<ul>
	<li>RESTful Interface Tool (iLOREST) 7.4.0.0 or&nbsp;later</li>
</ul>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Refer &quot;Updating iLO or server firmware&quot; section of iLO8 User Guide.</p>

<p><a href="https://support.hpe.com/hpesc/public/docDisplay?docId=sd00008382en_us&amp;docLocale=en_US&amp;page=GUID-5AB7C4FE-B6E8-4458-8F77-94248DDB1C11.html">iLO8 v1.10.00 User Guide</a></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Refer &quot;Updating iLO or server firmware&quot; section of iLO8 User Guide.</p>

<p><a href="https://support.hpe.com/hpesc/public/docDisplay?docId=sd00008382en_us&amp;docLocale=en_US&amp;page=GUID-5AB7C4FE-B6E8-4458-8F77-94248DDB1C11.html">iLO8 v1.10.00 User Guide</a></p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>iLO 8&nbsp;User Guide and other guides&nbsp;can be found by following the link&nbsp;at:<br />
<br />
<a href="https://support.hpe.com/hpesc/public/docDisplay?docId=sd00004310en_us&amp;docLocale=en_US">HPE iLO Documentation Quick Links</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>iLO 8&nbsp;User Guide and other guides&nbsp;can be found by following the link&nbsp;at:<br />
<br />
<a href="https://support.hpe.com/hpesc/public/docDisplay?docId=sd00004310en_us&amp;docLocale=en_US">HPE iLO Documentation Quick Links</a></p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="ubuntu2604" major="26" minor="04" sr="OEM" name="Ubuntu 26.04 LTS"/>
            <supported_operating_system platform="Linux" major="10" minor="0" sr="OEM" name="Oracle Linux 10"/>
            <supported_operating_system platform="Linux" major="9" minor="0" sr="OEM" name="Oracle Linux 9"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="other">
                <supported_device_data name="id">2F317B9D-C9E3-4D76-BFF6-B9D0D085A952</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3307</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">103c</supported_device_data>
                <supported_device_data name="dev">3306</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">04BD</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="90000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="No">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="RI14" guid="">
              <sw_key_expectedpath>firmware:ilo8</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>ilo8_1.10.00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="64MB" bytes="67127655" date_modified="2026-09-24T00:40:52" md5sum="7a33f81474fd4205cdb5a761a70e8eaf" sha1sum="02f57600ada1e9319c925d048e7a8729e1e2ccd2" sha256sum="d459e4c97a1cb3b5ff63396bcf91e122548896eba428b1bbf4e3a92caab083a2" sha512sum="245b4377e591437efb71af9ef7246694c1e0209f13e2f84a233748da9088e6083752f4303ded738139b1aac4c739fc022731affcce504c621365fa6b422caf08">
            <name>ilo8_1.10.00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/ilo8_1.10.00.fwpkg</url>
            <file_list>
              <file>ilo8_1.10.00.bin</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>2f317b9d-c9e3-4d76-bff6-b9d0d085a952</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30eff08</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30e0008</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30e0108</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30e0208</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30e0308</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
            <Device>
              <DeviceName>iLO 8</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>120</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>ilo8_1.10.00.bin</FileName>
                <InstallDurationSec>240</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>False</PLDMImage>
                <ResetRequired>False</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>False</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>fb2b2f91-c952-4288-8389-21dee30e0408</Target>
              <Version>1.10.00_pass_28</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="4f647319868f48cbaf207ad5f8a354e4">
      <product_version>
        <id product="4f647319868f48cbaf207ad5f8a354e4" version="71328499a3764b139c3f3e9b661fe0ce" lucid_version="intel_lkv.w2k25@1.8.54.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="1"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Intel ixwドライバーfor Windows Server 2025</name_xlate>
          <name_xlate lang="en">Intel ixw Driver for Windows Server 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel ixwドライバーfor Windows Server 2025</alt_name_xlate>
          <alt_name_xlate lang="en">Intel ixw Driver for Windows Server 2025</alt_name_xlate>
        </alt_name>
        <version value="1.8.54.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="35"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているIntel ixw 10 Gigabit Ethernet NIC用のドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the driver for Intel ixw 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57B1</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="400"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="ixw.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ecce65d793">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073016.exe</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1218448" date_modified="2026-09-01T08:04:21" md5sum="1d3f16679cce12246bbe5aac11b88160" sha1sum="443405a6f123723ed7dcfc2839e3797ee5a322da" sha256sum="18802c05aa7c4c8a9131f93b43dbc2d5fcc87e436d52815d160f6263f01564fc" sha512sum="52745553277c13c7e397614711427b1731f7bcb9007ccf3575eccfb055cc30b12a1a1711902d8e351270c0108da693261a7afc77fdbe0397f773cb5aebba332e">
            <name>cp073016.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073016.exe</url>
            <file_list>
              <file>cp073016.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>ixw.cat</file>
              <file>ixw.inf</file>
              <file>ixw.sys</file>
              <file>ixwmsg.dll</file>
              <file>nicdrvr.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="015fb436dd2948789e37f0213e4e8ee0">
      <product_version>
        <id product="015fb436dd2948789e37f0213e4e8ee0" version="343efb5f46d247279aad3285292395c4" lucid_version="Gen10P_Gen11_MR_Controller.rhel10.x86_64.rpm@07.738.06.0__pubsw-linux_en"/>
        <different>new</different>
        <build number="7"/>
        <type id="publishablesoftware-linux"/>
        <name>
          <name_xlate lang="ja">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10</name_xlate>
          <name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controlers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10</alt_name_xlate>
          <alt_name_xlate lang="en">HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controlers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10</alt_name_xlate>
        </alt_name>
        <version value="07.738.06.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="9">
            <division_xlate lang="ja">ストレージ</division_xlate>
            <division_xlate lang="en">Storage</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300214">
          <category_xlate lang="ja">ドライバ - ストレージ コントローラ</category_xlate>
          <category_xlate lang="en">Driver - Storage Controller</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="05" day="09" hour="01" minute="50" second="18"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 10 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 10 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel10uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>

<p>A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>To install the driver, type the following command:<br />
# rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel10uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>

<p>A REBOOT is required for your computer when the setup is complete.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0293</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0328</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0325</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0329</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">03C8</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0326</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032B</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032A</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">032C</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">1000</supported_device_data>
                <supported_device_data name="dev">10E2</supported_device_data>
                <supported_device_data name="subven">1590</supported_device_data>
                <supported_device_data name="subdev">0448</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace/>
        </prerequisites>
        <installation>
          <install>
            <install_caps/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps/>
            <command/>
            <command_params/>
            <reboot_required/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="kmod-megaraid_sas" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
          <sw_keys_and>
            <sw_key name="kmod-megaraid_sas" guid="20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499">
              <sw_key_expectedpath>software:rpm</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.rpm</filename>
        <component_config/>
        <files>
          <file size="143KB" bytes="147441" date_modified="2026-09-03T11:36:40" md5sum="455b879ee5e7483d5a43ceaba2afc47f" sha1sum="3da214f44e4c3c9c1039e96d3e6de99e96b8eb19" sha256sum="79a0a0cebca842c9ea19732b7d692f11df67880c66794bfcbc2422e7c0fdf650" sha512sum="30a9af8525a789e5051ff0b4f3700e5410afa1de82822f884a3c24f722bc59eb95ebe69362122d0ed7b1dd9b7212e7ea6fead385a332b25a0d4325d7dce52dd8" version="07.738.06.0_rhel10u2" release="1">
            <name>kmod-megaraid_sas-07.738.06.0_rhel10u2-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-megaraid_sas-07.738.06.0_rhel10u2-1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/megaraid_sas.conf</file>
              <file>./etc/dracut.conf.d/megaraid_sas.conf</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/megaraid_sas</file>
              <file>./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/megaraid_sas/megaraid_sas.ko</file>
              <file>./usr/share/smartupdate/kmod-megaraid_sas/component.xml</file>
            </file_list>
          </file>
          <file size="144KB" bytes="147797" date_modified="2026-09-03T11:29:53" md5sum="19a667868ebab4f09ff91bca90b882bc" sha1sum="742b6aca76c93920661170a83fba000cc2b6202c" sha256sum="6b3f1ceb945b2b8978db2f338157041aef175835670e3d0bb28a0b52a6766578" sha512sum="283123ae13b0a2f357f075157a5333c2ec4ad55a1480ba1c487eefa06c8e36123b27a00323d0fa17067a10d9fbe6628e5aa5cae00fe0e26b07e8263f45602a3d" version="07.738.06.0_rhel10u1" release="1">
            <name>kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.rpm</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.rpm</url>
            <file_list>
              <file>./etc/depmod.d/megaraid_sas.conf</file>
              <file>./etc/dracut.conf.d/megaraid_sas.conf</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas</file>
              <file>./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas/megaraid_sas.ko</file>
              <file>./usr/share/smartupdate/kmod-megaraid_sas/component.xml</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="0da3a133df4545c891ed30762e148ee5">
      <product_version>
        <id product="0da3a133df4545c891ed30762e148ee5" version="155f3cd1854443b1949694a534848483" lucid_version="nicfwpkg_bcme_57412_2p10ocp_baseT@238.1.169.0__fwpkg-generic_en"/>
        <different>new</different>
        <build number="18"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">Broadcom Firmware Package for BCM57412 BASE-T OCP3 adapter</name_xlate>
          <name_xlate lang="en">Broadcom Firmware Package for BCM57412 BASE-T OCP3 adapter</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Broadcom Firmware Package for BCM57412 BASE-T OCP3 adapter</alt_name_xlate>
          <alt_name_xlate lang="en">Broadcom Firmware Package for BCM57412 BASE-T OCP3 adapter</alt_name_xlate>
        </alt_name>
        <version value="238.1.169.0" revision="" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="10" day="04" hour="00" minute="00" second="00"/>
        <description>
          <description_xlate lang="ja"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 BASE-T OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57412 BASE-T OCP3 Gigabit Ethernet NIC firmware.]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p style="margin-left:0px; margin-right:0px; text-align:left">Flash the PLDM firmware using any below methods</p>

<ol style="list-style-type:decimal">
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p style="margin-left:0px; margin-right:0px; text-align:left">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool" style="color: rgb(0, 0, 255); text-decoration: none;">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px; margin-right:0px; text-align:left">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p style="margin-left:0px; margin-right:0px; text-align:left">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px; margin-right:0px; text-align:left"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp" style="color: rgb(0, 0, 255); text-decoration: none;">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul style="list-style-type:square">
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658" style="color: rgb(0, 0, 255); text-decoration: none;">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li>
	<p style="margin-left:0px; margin-right:0px">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px; margin-right:0px; text-align:left">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px; margin-right:0px; text-align:left">Reboot your system for the update to take effect immediately</p>

<p style="margin-left:0px; margin-right:0px; text-align:left">3.&nbsp;Flash from iLO GUI</p>

<ul style="list-style-type:square">
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>

<p><strong><em>Additional Information:</em></strong></p>

<ul>
	<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57412 Ethernet 10Gb 2-port BASE-T OCP3 Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<ul>
	<li>This software package contains NVM Image version 238.1.169.0 with the following firmware versions:
	<table border="1">
		<thead>
			<tr>
				<th>NIC</th>
				<th>Bootcode Version</th>
				<th>NCSI Version</th>
				<th>MBA Version</th>
				<th>UEFI Version</th>
				<th>RoCE Version</th>
			</tr>
		</thead>
		<tbody>
			<tr>
				<td>Broadcom BCM57412 Ethernet 10Gb 2-port BASE-T OCP3 Adapter for HPE</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.154.0<br />
				&nbsp;</td>
				<td colspan="1" rowspan="3">238.1.168.0<br />
				&nbsp;</td>
			</tr>
		</tbody>
	</table>
	</li>
</ul>

<ul>
	<li>To update NVM image version 233.1.135.7 and prior versions, please use Broadcom Firmware Package for BCM5741x adapters (links are listed below) for update:
	<ul>
		<li>
		<p>Broadcom Firmware Package for BCM5741x adapters:</p>

		<p><a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes" id="OWA4e9d1829-50d7-3caf-6911-3cd5552aca0d" title="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-5fcadb289d2a4581&amp;tab=releaseNotes</a></p>
		</li>
	</ul>
	</li>
</ul>

<p>&nbsp;</p>

<ul>
</ul>

<ul>
	<li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li>
</ul>

<p style="margin-left:80px"><a href="https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31" target="_blank">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16D6</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EE</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16EF</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16DC</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C1</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16C5</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">14E4</supported_device_data>
                <supported_device_data name="dev">16BD</supported_device_data>
                <supported_device_data name="subven">14E4</supported_device_data>
                <supported_device_data name="subdev">E320</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="11000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="BCM_NXE_57412OCP_BASET_PKG" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>BCM238.1.169.0_BCM957412N210TH00.fwpkg</filename>
        <component_config/>
        <files>
          <file size="1MB" bytes="1693990" date_modified="2026-08-18T05:39:15" md5sum="679b062f39889dd29eac18d40634c299" sha1sum="9ec57739f6aa96a488d21adafde77e8adca6d057" sha256sum="0b783f91c656423daf9397010bd763f14842de8660c52278bf6287cf8ef91d70" sha512sum="b65e8cdef37689034899611b716517facde21c7de622070adec8caecc0fda13107734a23495a2cbb5e9949fd3232d6fbcc41866a6bd798fdf1d1351270c927ac">
            <name>BCM238.1.169.0_BCM957412N210TH00.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/BCM238.1.169.0_BCM957412N210TH00.fwpkg</url>
            <file_list>
              <file>BCM238.1.169.0_BCM957412N210TH00.HPb</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16d614e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ee14e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16ef14e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16dc14e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c114e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16c514e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
            <Device>
              <DeviceName>Broadcom NetXtreme-E BCM57412 BASE-T OCP3 adapters</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>BCM238.1.169.0_BCM957412N210TH00.HPb</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-14e4-16bd14e4e320</Target>
              <Version>238.1.169.0</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>ComboFirmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
    <product id="a83500e26a4d4bb89a4eb5821b7b2ca6">
      <product_version>
        <id product="a83500e26a4d4bb89a4eb5821b7b2ca6" version="9acb1af56e8c4bbab0fcf48b3c1de9c4" lucid_version="amdpshed.win2025.x64@1.0.0.54(B)__sc-windows_en"/>
        <different>new</different>
        <build number="3"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">AMD PSHEDプラグインサービスfor Microsoft Windows Server 2022および2025</name_xlate>
          <name_xlate lang="en">AMD PSHED Plug-in service for Microsoft Windows Server 2022 and 2025</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">AMD PSHEDプラグインサービス</alt_name_xlate>
          <alt_name_xlate lang="en">AMD PSHED Plug-in service</alt_name_xlate>
        </alt_name>
        <version value="1.0.0.54" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
        </divisions>
        <category key="11300027">
          <category_xlate lang="ja">ドライバ - システム</category_xlate>
          <category_xlate lang="en">Driver - System</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="08" day="27" hour="06" minute="10" second="16"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントはAMD PSHEDサービスをインストールします]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This components installs the AMD PSHED service]]></description_xlate>
        </description>
        <prerequisite_notes/>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>

<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>

<p>[インストール]ボタンをクリックして、インストールを開始します。</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>

<p>From that drive and directory, execute the downloaded file.</p>

<p>Click the &quot;Install&quot; button to proceed with the installation.</p>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="26100" maximumbuild="26100" name="Azure Local 24H2"/>
          </supported_operating_systems>
          <supported_devices/>
          <supported_platforms>
            <supported_platform rom="A41"/>
            <supported_platform rom="A55"/>
            <supported_platform rom="A56"/>
            <supported_platform rom="A46"/>
            <supported_platform rom="A48"/>
            <supported_platform rom="A58"/>
            <supported_platform rom="A66"/>
            <supported_platform rom="A40"/>
            <supported_platform rom="A47"/>
            <supported_platform rom="A72"/>
            <supported_platform rom="A42"/>
            <supported_platform rom="A43"/>
          </supported_platforms>
          <required_diskspace size_kb="100"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>60</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="amdpshed.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9eca8078e42">
              <sw_key_expectedpath>%systemroot%\system32\drivers</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp072794.exe</filename>
        <component_config/>
        <files>
          <file size="677KB" bytes="693584" date_modified="2026-09-14T05:27:17" md5sum="7086e9ec4a00829aeb94b84474e2b15f" sha1sum="d57c67148a759620bab7d02f03ee58e1a40bf172" sha256sum="316d0c9a14392c18f54ba99b4ce5bc56cb233f1e30641af55553b950f8dc549c" sha512sum="ae5ee91bcc42dd748946196df94ca6c8e474a5de5034001290db5dd0bebec2877638b9240220f5993ff2470906c272af38e87a51ff5e23356b802b110c11f7ca">
            <name>cp072794.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp072794.exe</url>
            <file_list>
              <file>cp072794.xml</file>
              <file>cpqsetup.exe</file>
              <file>installer.dll</file>
              <file>non-pnp/</file>
              <file>non-pnp/amdpshed.cat</file>
              <file>non-pnp/amdpshed.inf</file>
              <file>non-pnp/amdpshed.sys</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="83e1148b5c0344d788a4b7811addf33e">
      <product_version>
        <id product="83e1148b5c0344d788a4b7811addf33e" version="131830f0a0184a5389a9218753a73b45" lucid_version="intel_lkv_vf.w2k22@2.3.7.0(B)__sc-windows_en,ja"/>
        <different>new</different>
        <build number="4"/>
        <type id="smartcomponent-windows"/>
        <name>
          <name_xlate lang="ja">Intel vxsドライバーfor Windows Server 2022</name_xlate>
          <name_xlate lang="en">Intel vxs Driver for Windows Server 2022</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">Intel vxsドライバーfor Windows Server 2022</alt_name_xlate>
          <alt_name_xlate lang="en">Intel vxs Driver for Windows Server 2022</alt_name_xlate>
        </alt_name>
        <version value="2.3.7.0" revision="B" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems/>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en"/>
          </division>
        </divisions>
        <category key="11300095">
          <category_xlate lang="ja">ドライバ - ネットワーク</category_xlate>
          <category_xlate lang="en">Driver - Network</category_xlate>
        </category>
        <languages langlist="en,ja">
          <languages_xlate lang="ja">英語（US）,日本語</languages_xlate>
          <languages_xlate lang="en">English (US),Japanese</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="13" hour="09" minute="24" second="36"/>
        <description>
          <description_xlate lang="ja"><![CDATA[このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。]]></description_xlate>
          <description_xlate lang="en"><![CDATA[This Component Package contains the vxs driver for Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022.]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>このドライバーではホストドライバーバージョン1.4.73.0以降が必要です。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>This driver requires host driver version 1.4.73.0 or later.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the "Install" button to proceed with the installation.<br>]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes/>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="20317" maximumbuild="25398" name="Microsoft Windows Server 2022"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25398" maximumbuild="25398" name="Azure Stack HCI 23H2"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57ad</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">00FF</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">8086</supported_device_data>
                <supported_device_data name="subdev">0003</supported_device_data>
              </supported_device>
            </supported_devices_and>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">8086</supported_device_data>
                <supported_device_data name="dev">57AD</supported_device_data>
                <supported_device_data name="subven">0000</supported_device_data>
                <supported_device_data name="subdev">0000</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="400"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="yes" needuseracct="no"/>
            <command>cpqsetup.exe</command>
            <command_params/>
            <reboot_required value="no"/>
            <reboot_details value="Optional">
              <reboot_details_xlate lang="ja">インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>0</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="vxs.sys" guid="20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727">
              <sw_key_expectedpath>%systemroot%\System32\DriverStore\FileRepository\vxs.inf_amd64_d6120d6ae1cc028c</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>cp073017.exe</filename>
        <component_config/>
        <files>
          <file size="834KB" bytes="854568" date_modified="2026-09-02T02:23:19" md5sum="7981a5af2e10135ff78549c80342602b" sha1sum="a187bf8e7397341a3b25121f389dba2f64650b44" sha256sum="2c581508820b9f296930f74c02308af0cf77862cabc7858a3c2711d130fbf257" sha512sum="2baaf4b16ee4249d8c4c72ea21cbf4e2903c3287815183d66beb123cfcddcc8b16828775c4b85d18f5e50be7406988d9f2ca3e26e6b44b8fe3044dd908a4a28e">
            <name>cp073017.exe</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/cp073017.exe</url>
            <file_list>
              <file>cp073017.xml</file>
              <file>cpqsetup.exe</file>
              <file>cp_data.xml</file>
              <file>install.xml</file>
              <file>nicdrvr.dll</file>
              <file>vxs.cat</file>
              <file>vxs.inf</file>
              <file>vxs.sys</file>
              <file>vxsmsg.dll</file>
            </file_list>
          </file>
        </files>
        <file_details/>
      </product_version>
    </product>
    <product id="b50552ebf09d445294b0b81e162643cf">
      <product_version>
        <id product="b50552ebf09d445294b0b81e162643cf" version="9c4916603dc04cdcb314d13738fdadf4" lucid_version="FWPKG-P42044-B21@26.49.1014(A)__fwpkg-generic_en"/>
        <different>new</different>
        <build number="2"/>
        <type id="universal-fw-generic"/>
        <name>
          <name_xlate lang="ja">NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE</name_xlate>
          <name_xlate lang="en">NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE</name_xlate>
        </name>
        <alt_name>
          <alt_name_xlate lang="ja">NVIDIAファームウェアパッケージ(FWPKG)- Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE</alt_name_xlate>
          <alt_name_xlate lang="en">NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE</alt_name_xlate>
        </alt_name>
        <version value="26.49.1014" revision="A" type_of_change="1"/>
        <manufacturer_name>
          <manufacturer_name_xlate lang="ja">Hewlett Packard Enterprise</manufacturer_name_xlate>
          <manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
        </manufacturer_name>
        <operating_systems>
          <operating_system key="10967">
            <operating_system_xlate>Red Hat Enterprise Linux 9 Server</operating_system_xlate>
          </operating_system>
          <operating_system key="9398">
            <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
          </operating_system>
          <operating_system key="11458">
            <operating_system_xlate>Microsoft Windows Server 2025</operating_system_xlate>
          </operating_system>
          <operating_system key="11552">
            <operating_system_xlate>Red Hat Enterprise Linux 10</operating_system_xlate>
          </operating_system>
          <operating_system key="11729">
            <operating_system_xlate>SUSE Linux Enterprise Server 16</operating_system_xlate>
          </operating_system>
        </operating_systems>
        <products>
          <product rom="A72"/>
        </products>
        <divisions>
          <division key="65">
            <division_xlate lang="ja">ネットワーク</division_xlate>
            <division_xlate lang="en">Networking</division_xlate>
          </division>
          <division key="6">
            <division_xlate lang="ja">サーバ</division_xlate>
            <division_xlate lang="en">Server</division_xlate>
          </division>
          <division key="68">
            <division_xlate lang="ja">サーバ オプション</division_xlate>
            <division_xlate lang="en">ServerOptions</division_xlate>
          </division>
        </divisions>
        <category key="2900095">
          <category_xlate lang="ja">ファームウェア - ネットワーク</category_xlate>
          <category_xlate lang="en">Firmware - Network</category_xlate>
        </category>
        <languages langlist="en">
          <languages_xlate lang="ja">英語（US）</languages_xlate>
          <languages_xlate lang="en">English (US)</languages_xlate>
        </languages>
        <release_date year="2026" month="09" day="24" hour="09" minute="05" second="55"/>
        <description>
          <description_xlate lang="ja"><![CDATA[NVIDIA HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE]]></description_xlate>
          <description_xlate lang="en"><![CDATA[NVIDIA HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE]]></description_xlate>
        </description>
        <prerequisite_notes>
          <prerequisite_notes_xlate lang="ja">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKGは、アダプターにフラッシュされたファームウェアバージョンが20.27.1016以降の場合にのみ機能し、iLO5ファームウェアバージョンは2.30以降である必要があります。</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
          <prerequisite_notes_xlate lang="en">
            <prerequisite_notes_xlate_part><![CDATA[<p>FWPKG will work only if the firmware version flashed on the adapter is 20.27.1016 or later and iLO5 firmware version must be 2.30 or higher.</p>
]]></prerequisite_notes_xlate_part>
          </prerequisite_notes_xlate>
        </prerequisite_notes>
        <installation_notes>
          <installation_notes_xlate lang="ja">
            <installation_notes_xlate_part><![CDATA[<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>

<ol>
	<li>iLOrestツールを使用したフラッシュ </li>
	<li>Smart Update Manager（SUM）を使用したフラッシュ</li>
	<li>iLO GUIからのフラッシュ</li>
</ol>

<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>を参照してください。</p>

<p style="margin-left:40px">ローカルホストOSの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>

<p style="margin-left:40px">リモートの例:<br />
<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>

<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>

<p style="margin-left:40px">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>

<ul>
	<li style="margin-left: 80px;">
	<p><strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>
	</li>
	<li style="margin-left: 80px;">
	<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの"\packages"ディレクトリにコピーします。</p>
	</li>
</ul>

<p style="margin-left:40px">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>

<p style="margin-left:40px">アップデートを直ちに有効にするにはシステムを再起動してください。</p>

<p>3.  iLO GUIからのフラッシュ</p>

<ul>
	<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>
	<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>
	<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>
	<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>
	<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
          <installation_notes_xlate lang="en">
            <installation_notes_xlate_part><![CDATA[<p>Flash the PLDM firmware using any below methods</p>

<ol>
	<li>Flash using iLOrest tool&nbsp;</li>
	<li>Flash using&nbsp;Smart Update Manager (SUM).</li>
	<li>Flash from iLO GUI</li>
</ol>

<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href="http://www.hpe.com/servers/resttool">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>

<p style="margin-left:40px">localhost OS example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>

<p style="margin-left:40px">remote example:<br />
<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>

<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>

<p style="margin-left:40px"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href="http://www.hpe.com/info/spp">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>

<ul>
	<li style="margin-left: 80px;">
	<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href="https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658">USB Key Creator Utility</a></strong>.</p>
	</li>
	<li style="margin-left: 80px;">
	<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\packages&quot; on the USB key.</p>
	</li>
</ul>

<p style="margin-left:40px">Update the firmware and software&nbsp;in the usual manner.</p>

<p style="margin-left:40px">Reboot your system for the update to take effect immediately</p>

<p>3.&nbsp;Flash from iLO GUI</p>

<ul>
	<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>
	<li>Make sure the PLDM supported adapter is present in the server</li>
	<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>
	<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>
	<li>Reboot the server for the firmware update to take effect.</li>
</ul>
]]></installation_notes_xlate_part>
          </installation_notes_xlate>
        </installation_notes>
        <availability_notes/>
        <documentation_notes>
          <documentation_notes_xlate lang="ja">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td>
			<td>26.49.1014</td>
			<td>MT_0000000575</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
          <documentation_notes_xlate lang="en">
            <documentation_notes_xlate_part><![CDATA[<p>This software package contains the following firmware versions:</p>

<table border="1" cellpadding="1" cellspacing="1">
	<tbody>
		<tr>
			<td><strong>NVIDIA Ethernet Only Adapters</strong></td>
			<td><strong>Firmware Version</strong></td>
			<td><strong>PSID</strong></td>
		</tr>
		<tr>
			<td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td>
			<td>26.49.1014</td>
			<td>MT_0000000575</td>
		</tr>
	</tbody>
</table>

<p>&nbsp;</p>
]]></documentation_notes_xlate_part>
          </documentation_notes_xlate>
        </documentation_notes>
        <upgrade_requirement value="Recommended"/>
        <prerequisites>
          <supported_operating_systems>
            <supported_operating_system platform="nt_x86-64" major="6" minor="3" sr="OEM" name="Microsoft Windows Server 2012 R2"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="14393" maximumbuild="17599" name="Microsoft Windows Server 2016"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="17600" maximumbuild="18999" name="Microsoft Windows Server 2019"/>
            <supported_operating_system platform="oi" major="0" minor="0" sr="OEM" name="Cross Operating System"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="6" minor="0" sr="OEM" name="Red Hat Enterprise Linux 6 Server (x86-64)"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="7" minor="0" sr="OEM" name="Red Hat Enterprise Linux 7 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="8" minor="0" sr="OEM" name="Red Hat Enterprise Linux 8 Server"/>
            <supported_operating_system platform="red_hat_enterprise_linux_x86_64" major="9" minor="0" sr="OEM" name="Red Hat Enterprise Linux 9"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="11" minor="0" sr="OEM" name="SUSE LINUX Enterprise Server 11 (AMD64/EM64T)"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
            <supported_operating_system platform="vmware_esx_server" major="7" minor="0" sr="OEM" name="VMware ESXi 7.0"/>
            <supported_operating_system platform="vmware_esx_server" major="8" minor="0" sr="OEM" name="VMware ESXi 8.0"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="5" sr="OEM" name="VMware vSphere 6.5"/>
            <supported_operating_system platform="vmware_esx_server" major="6" minor="7" sr="OEM" name="VMware vSphere 6.7"/>
            <supported_operating_system platform="nt_x86-64" major="10" minor="0" sr="OEM" minimumbuild="25399" name="Microsoft Windows Server 2025"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="0" sr="OEM" name="VMware ESXi 9.0"/>
            <supported_operating_system platform="vmware_esx_server" major="9" minor="1" sr="OEM" name="VMware ESXi 9.1"/>
            <supported_operating_system platform="Red_Hat_Enterprise_Linux_x86_64" major="10" minor="0" sr="OEM" name="Red Hat Enterprise Linux 10"/>
            <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="16" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 16"/>
          </supported_operating_systems>
          <supported_devices>
            <supported_devices_and>
              <supported_device type="pci">
                <supported_device_data name="ven">15b3</supported_device_data>
                <supported_device_data name="dev">101f</supported_device_data>
                <supported_device_data name="subven">15b3</supported_device_data>
                <supported_device_data name="subdev">0012</supported_device_data>
              </supported_device>
            </supported_devices_and>
          </supported_devices>
          <required_diskspace size_kb="32000"/>
        </prerequisites>
        <installation>
          <install>
            <install_caps silent="no" needuseracct="no"/>
            <command/>
            <command_params/>
            <reboot_required value="yes"/>
            <reboot_details value="Required">
              <reboot_details_xlate lang="ja">アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。</reboot_details_xlate>
              <reboot_details_xlate lang="en">Reboot is required after installation for updates to take effect and hardware stability to be maintained.</reboot_details_xlate>
            </reboot_details>
            <per_device_install_time_seconds>360</per_device_install_time_seconds>
          </install>
          <uninstall>
            <uninstall_caps silent="no"/>
            <command/>
            <command_params/>
            <reboot_required value="no"/>
          </uninstall>
        </installation>
        <sw_keys>
          <sw_keys_and>
            <sw_key name="Mellanox_NIC_PLDM_MCX631102AS-ADAT" guid="">
              <sw_key_expectedpath>firmware:nic</sw_key_expectedpath>
            </sw_key>
          </sw_keys_and>
        </sw_keys>
        <filename>26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg</filename>
        <component_config/>
        <files>
          <file size="7MB" bytes="7355901" date_modified="2026-08-27T12:23:15" md5sum="34f5c641b8d85ef7e721049b7679ff18" sha1sum="b8ca210fabb1f189250f1952f8b4c2d0b3a3fded" sha256sum="2422a8b32f8fa3bb353ca638e18d0dbd8e1ff9f69b9e24646729631f4314b068" sha512sum="a57ed7ec2c609ab0601f6f78d40bb7ec068b279bfcca7b281282b8e05669ba40d6a7218ea990bead7712c7cf7aa3f6dcbf4b1b8ab7ef0b3dccafadb80dc35488">
            <name>26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg</name>
            <url id="http://ftp.hp.com"/>
            <url id="file://.">file://./packages/26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg</url>
            <file_list>
              <file>26_49_1014-MCX631102AS-ADA_Ax.pldm.signed</file>
              <file>26_49_1014-MCX631102AS-ADA_Ax.pldm.xml</file>
              <file>payload.json</file>
            </file_list>
          </file>
        </files>
        <file_details/>
        <payload>
          <DeviceClass>79f0c163-0c13-4662-9dea-09235fef90cb</DeviceClass>
          <Devices>
            <Device>
              <DeviceName>MLX MCX631102 10/25GbE 2p SFP28 Adptr</DeviceName>
              <FirmwareImages>
                <DelayAfterInstallSec>0</DelayAfterInstallSec>
                <DirectFlashOk>True</DirectFlashOk>
                <FileName>26_49_1014-MCX631102AS-ADA_Ax.pldm.signed</FileName>
                <InstallDurationSec>360</InstallDurationSec>
                <Order>1</Order>
                <PLDMImage>True</PLDMImage>
                <ResetRequired>True</ResetRequired>
                <ServerPowerOff>False</ServerPowerOff>
                <SysPowerON>True</SysPowerON>
                <Type>Firmware</Type>
                <UefiFlashable>False</UefiFlashable>
              </FirmwareImages>
              <Target>a6b1a447-382a-5a4f-15b3-101f15b30012</Target>
              <Version>26.49.1014</Version>
            </Device>
          </Devices>
          <PackageFormat>FWPKG-v2</PackageFormat>
          <Type>Firmware</Type>
          <UpdatableBy>Bmc</UpdatableBy>
        </payload>
      </product_version>
    </product>
  </meta>
</manifest>
